HomeMy WebLinkAboutSW6140801_APPROVED PLANS_20140903 (2)STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. sw_&�1 DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE���%%� YYYYMMDD y, c GENERAL NOTES: 1. ALL ABOVE AND UNDERGROUND UTILITIES ARE APPROXIMATE LOCATION BASED ON FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL FIELD VERIFY THE SIZE, DEPTH, LOCATION, AND MATERIAL OF ALL EXISTING UTILITIES PRIOR TO THE START OF CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 2. ANY DISCREPANCIES FOUND BETWEEN THE DRAWINGS AND SPECIFICATIONS AND SITE CONDITIONS OR ANY INCONSISTENCIES OR AMBIGUITIES IN THE DRAWINGS OR SPECIFICATIONS SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER IN WRITING WHO WILL ADDRESS THE CONCERNS. WORK DONE BY THE CONTRACTOR AFTER THE DISCOVERY OF SUCH DISCREPANCIES INCONSISTENCIES OR AMBIGUITIES SHALL BE DONE SOLELY AT THE CONTRACTOR'S RISK. 3. THE CONTRACTOR SHALL CONTACT NC ONE CALL CENTER AT LEAST 48 HOURS BEFORE THE START OF CONSTRUCTION 1-800-632-4949. 4. THE CONTRACTOR SHALL CAREFULLY SUPPORT AND PROTECT ANY UTILITIES, STRUCTURES, POWER POLES, PIPE LINE AND CONDUITS, ETC. WHICH MAY BE ENCOUNTERED DURING CONSTRUCTION. ANY DAMAGE RESULTING FROM THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED AND RESTORED BY THE CONTRACTOR AT THEIR EXPENSE TO THE SATISFACTION OF THE ENGINEER OR OWNER OF THE UTILITY. 5. THE CONTRACTOR SHALL VERIFY WITH THE UTILITY COMPANIES THAT UTILITY SERVICES ARE DISCONNECTED PRIOR TO BEGINNING DEMOLITION. 6. THE CONTRACTOR SHALL USE DEMOLITION METHODS THAT DO NOT DAMAGE ADJACENT STRUCTURES, ROADS, AND OR UTILITIES. 7. THE CONTRACTOR SHALL WORK ONLY DURING TIMES APPROVED BY THE OWNER OR AS REQUIRED BY THE COUNTY OR OTHER AGENCY. 8. THE CONTRACTOR SHALL PROVIDE ALL SAFETY BARRIERS AS REQUIRED BY THE COUNTY OR AS NECESSARY TO PROTECT THE PUBLIC AND THE SITE. 9. THE CONTRACTOR SHALL PROPERLY DISPOSE OF ALL DEBRIS OFF SITE AT AN APPROVED DISPOSAL FACILITY. DEBRIS INCLUDE BUT ARE NOT LIMITED TO ROOTS, TREES, STUMPS, UNSUITABLE SOILS, CONCRETE, ASPHALT, AND BUILDING MATERIALS. 10. TREES SHALL BE COMPLETELY REMOVED INCLUDING ROOTS. 11. ON SITE BURNING IS NOT PERMITTED. 12. THE CONTRACTOR SHALL REVIEW, VERIFY, AND COORDINATE ALL DIMENSIONS SHOWN ON THE PLANS INCLUDING BUT NOT LIMITED TO THE HORIZONTAL AND VERTICAL LOCATION OF WATER, STORM, AND SANITARY STRUCTURES AND CROSSINGS PRIOR TO STARTING WORK. 13. DISTANCES SHOWN ARE MEASURED HORIZONTALLY 14. THE CONTRACTOR SHALL COMPLY WITH THE APPROVED NCDOT ENCROACHMENT AGREEMENTS WHILE WORKING WITHIN THE NC DOT RIGHT 15. THE CONTRACTOR SHALL MAINTAIN TRAFFIC AT ALL TIMES DURING CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL MEASURES AS REQUIRED BY NC DOT DURING CONSTRUCTION IN IN THE ROADWAY OR WITHIN 5 FEET (OR GREATER IF REQUIRED BY NCDOT) OF THE EDGE OF PAVEMENT. M KNOW WHAT IS BELOW CALL BEFORE YOU DIG AMPLE STORAGE LAKE WORTH, LLC SITE PLAN McLAUCHLIN TOWNSHIP HOKE COUNTY., NORTH CAROLINA AUGUST 2014 AS J01jJJJV5 0N'0 VICINITY MAP N.T.S. DEVELOPER: LAMPE MANAGEMENT COMPANY PO BOX 608 SMITHFIELD, NC 27577 (919) 934-3041 TERRY WETHINGTON AMAN A0 1W ENGINEER & SURVEYOR: INDEX OF SHEETS SP-1 COVER SHEET SP-2 SEDIMENT & EROSION CONTROL PLAN SP-3 SITE PLAN SP-4 GRADING PLAN SP-5 UTILITY PLAN SP-6 SITE DETAILS SP-7 EROSIONS CONTROL DETAILS BATEMAN CIVIL SURVEY COMPANY 200 NORTH MAIN STREET HOLLY SPRINGS, NC 27540 (919) 577-1080 BRIAN KRAYNAK, PE STEVEN CARSON, PLS Approved Stormwater Permit Documents Construction in accordance with these documents is required by the stormwater permit. North Carolina rules require that the stormwater system designer Inspect during construction; certify conformity with the plans and specs: and certify compliance with the stormwater rules. (15A NCAC 21-1.1008 (j) ) Pe mit# / Date 97A -ZZI �G by NC Division of Water Quality Sheet # '55e Revision Date $'V- Z&ef, J. C ti3 n L CD OD O � 00 N L Z N U L. >. ro LL Z IA> mm� ? o -_ L N r W W •� V � d U) oi rn U z M v s a Ez W bJD o UJ M m J Z J s✓ ::3 O Q MIDc U C Q � .J CL W •.0 -O � p to f- �.m LL C: kn — W -C U J =3 Ca G U U j- W W U) W W O U Designed By: BJK Drawn By: BJK Checked By: TSS Scale: 1"= 40' Date: 72014 Revised: O O O 0 0 Project Number. 140264 SP-1 — tD x >• FUTURE, -A U r ONi` t SLAB z F� Fr���i.b t v�aap La 5r� 1 I q 3N j,i I �v 1_1 �•� vim, c-y PIN # 494660201299 N!F it I iJLtili 01:i FHOMAS FAMIL BUSINESS, INC 8 s3 DB 106Q, PG 564, ZONED: R-8 =6 VACANT T, O PIN # 494660201027 N/F PENNSYLVANIA TRANSFORMER DB 284, PG 889 ZONED: I INDUSTRIAL WF LAG HOKE, LLC ' ZONED: HC SELFSTORAGE x i Q - I of off. o ' S I ,:,RAGE BUILDING r I -- �- ,250 SF__ F=258.5 V _ � 12 DISTURBED AREA = 2.82 AC. WALL EXTENSION i STORAGE BUILDING 10,800 SF FF = 258.0 CURB BEGIN STORAGE BUILDING 11,700 SF FF = 257.5 LOT 1.. - 126,580 SF = 2.906 AC _ i 120' I ,130' use N 02'200' W 827.72' LOT 2 NEW LINE 976,206 SF= 22410AC PIN # 494660201014 MF DONRODNEYBROCK DB 61Z PG 154 1,102,786SF=25.316AC — ZONED: HC VACANT I I � E4 5TWG C8 I ;Grj4�17 = i o / .247.55 QJ LID Q EN I I E e I I O f° P Co t I A • ' I (n Z cN I j > LL z I a o r Pik OUTLET TO FILL UP S � LL + Cn NG I , �VJD OVER FLOW TO > LLJ I I -EXISTING DOT INLET a) Lo .� ar of m U I V "j °' Z v1 �)to L v I� W 2 ,_ o a Z v I I 4) o m LI..I Of i k o Pde Wall, m I III0 ILI. II c _ 0 i ' I � I I ' J Z a\ J V Wz _ ,, a -4 F— I RU S77NGTFLNE I (; Q O '� Ma) �- J O he _ I I j ! CC W LA �4-+ C I Q Q M F- W J V a � C J G U Q GRADING NOTES: 1. CONTRACTOR SHALL ENSURE POSITIVE DRAINAGE AWAY FROM THE BUILDINGS AND TOWARD THE CATCH BASINS. 2. SPOT ELEVATIONS SHOWN ARE FOR PAVEMENT ELEVATIONS UNLESS NOTED OTHERWISE. TIN IS FOR TOP OF WALL BW IS FOR BOTTOM OF WALL. 3. SOIL BORING LOCATIONS ARE APPROXIMATE. SEE SOIL REPORT FOR SOIL DESCRIPTIONS AND INFILTRATION RATES. 4. EXISTING TOP SOIL ON THE SITE SHALL BE STRIPED AND DISPOSED OF OFF SITE AT AN APPROVED LOCATION. 5. IT IS EXPECTED THAT THE SITE WILL REQUIRE FILL DIRT MATERIAL TO BE IMPORTED TO COMPLETE THIS PROJECT AS DESIGNED. 6. UNSUITABLE AND OR ACCESS MATERIAL SHALL BE REMOVED AND DISPOSED OF OFF SITE AT A APPROVE SITE OR DISPOSAL FACILITY. 7. SUBGRADE UNDER THE BUILDINGS AND PAVEMENT SHALL BE COMPACTED TO AT LEAST 98%. SUBGRADE SHALL BE TESTED PRIOR TO PLACING AGGREGATE BASE AND SLAB FOUNDATION STONE. (to arm) warn M 40 20 G 40 80 120 1 INCH = 40 FELT GRAPHIC SCALE Approved Stormwater Permit Documents Construction in accordance with these documents is required by the stormwater permit. North Carolina rules require that the stormwater system designer Inspect during construction; certify conformity with the plans and specs; and certify compliance with the stormwater rules. (15A NCAC 2H 1008 0) ) Permit # $ 1:/4/D 0 Date by NC Division of Water Quality Sheet # .�Revision Date $ • i/1 WI/ z V z Designed By: BJK Drawn By: BJK Checked By: TSS Scale: 1" = 40' Date: 712014 Revised: O O O O Project Number: 140264 S P-4 PIN # 494660201027 NIF PENNSYLVANIA TRANSFORMER DE 284, PG 889 ZONED: I INDUSTRIAL S 02°24'51' E 609,29' I _ T 258,U V V T 7.70 ITA,.� +L INV. 253.10 'i liiiiii 181 LF.24'RCP O�R01G 80 1 FUTURE BLDG 01 SLAB ON"Lei) D V i 0 1 c- L.nt AGE BUILDING Sr 258.5 FUTURE- UR`d 61-1)kG PIN # 49 4660201299 NIF �� I SIJ B ONLY THOMAS FAMILY BUSINESS, INC F 1, _. DB 1060, PG 564 N --.- - -' -- ZONED: R-8 - VACANT r z 9n S' V 1it� zo o, BUILDING -FLOOR 257 -------- -- ------- ---- S�OpF NOTES 255.5 FILTER WALL SEASONAL HIGH WATER 250 F TABLE BELOW 250 4, 6" PVC IN WALL 254 STORMWATER CROSS SECTION (NTS) 1. TRASH RACK SHALL BE BOLTED TO TOP OF CONCRETE STRUCTURE. MOUNTING WITH BOLTS IN SHEAR IS PROHIBITED. 2. BOLTS SHALL BE STAINLESS STEEL. 3. ALIGN ACCESS OPENING WITH STEPS AND SHALL BE AT LEAST 2' X 3' 4. STEEL REBARS SHALL BE PRIMED AND PAINTED BLACK. L„ T 8" AIV61_F Ii20iv c I D c j 2CATCH BASINS c SEE .DETAIL CB2 b 97 L.F.2A' RCP O-RING![7 (i `-'I, V 4 P STORAGE BUILDING STORAGE BUILDING 10,800 SF `'G' 11,700 SF FF = 257.5 FF = 258.0 , LOT 1' , - 126,580 SF= 2,906AC 120130' N 02°2,CW W 827.77 NEW LINE i.2 RETAINING WALL 256 WEIR HINGED ACCESS HATCH #4 SLLL 8" REBAR I TRASH RACK N.T.S. LOT2 976,206 SF= 22410AC PIN # 494660201014 NIF DONRODNEYBROCK DB612,PG154 ! 1,10Z786 SF= 25J16 AC ZONED:HC VACANT -PIN i6494660201013 NIF AMERICAN FLAG HOKF, LLC _ OB 759, PG 316 ZONED: HC SELFSTORAGE - SW2 r-E -MIT - oae�i_ _ �c _\ c PROi Os LOCATION \� Gl1YVIVO 38LF.OF24'FE ! STORAGE BUILDING ! 12,150 SF FF = 257.0 77 ta^x% �4 135' = I` 1VFES 1 j INV.251.54 14,z44'CrA RIP RAP?( PROPOSEa' CATCH ( 28 LF. OF 18' FES Q 0.5016 ,SW DETAIL CBI STUB POLE �1 SOIL BORE#3 LOCATION\ A HEAVY DITTY FRAME 8 GRATE (TYP) TOP=257.01 24'OPENINGIPIPE 2$RCP CONNECTION(TYP) ORING 4• 4' N 24 PIPE INV=253 24'RGP 24'RCP O R01G O RR1G 2rAw oras O oral wv=25321 INV-233.26 SLOPED IXPANSION INVERT OW) JOWT(TYP) CB 2 DETAIL (NTS) HEAVY DUTY FRAME 8 GRATE RP) TOP=256AO 2C RCP WOPENINGTIPE O RING CONNECTION(IYP) R 4' z 24' PIPE N INIV_ 24'RCP u•xra A=; EXPANSIONJONT(TYP) INV=25215 9 OPED 24'RCP RNB(T(TYP) oRa1G CB 1 DETAIL (NTS) CATCH R�SIN I j ... I TOP 255. _ INV.251S I 0 j 1 I INV. 251.71 j i33LF.OF4dFESQ0.50% /Q I 256 TOP Od10' SOD V(EIR ' O ` I BASIN 0 I WIlRASHK TOP 255.30I INV. 252.00,118r) i •V n;a g I INV. 252.20 r1') � \ 1 44 , 0 tkil tQ �11 I �y� 4• PElifoRATED PVf U�1DERDRAIN I I 1 (se are) amo �r I I 1 I 40 40 80 120 1 lNC,H = 40 r )_E I L GRAPHJC SCP.t-E NOTES: 1. ALL ABOVE AND UNDERGROUND UTILITIES ARE APPROXIMATE LOCATION AND BASED FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWING INFORMATION WHEN THIS PLAN WAS DEVELOPED. THE CONTRACTOR SHALL FIELD VERIFY THE SIZE, DEPTH, LOCATION, AND MATERIAL OF ALL EXISTING UTILITIES PRIOR TO THE START OF CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 2. THE CONTRACTOR SHALL CONTACT NC ONE CALL CENTER AT LEAST 48 HOURS BEFORE THE START OF CONSTRUCTION 1-800-632-4949. 3. THE CONTRACTOR SHALL CAREFULLY SUPPORT AND PROTECT ANY UTILITIES, STRUCTURES, POWER POLES, PIPE LINE AND CONDUITS, ETC. WHICH MAY BE ENCOUNTERED DURING CONSTRUCTION. ANY DAMAGE RESULTING FROM THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED AND RESTORED BY THE CONTRACTOR AT THEIR EXPENSE TO THE SATISFACTION OF THE ENGINEER OR OWNER OF THE UTILITY. 4 THE CONTRACTOR SHALL REVIEW, VERIFY, AND COORDINATE ALL DIMENSIONS SHOWN ON THE PLANS INCLUDING BUT NOT LIMITED TO THE HORIZONTAL AND VERTICAL LOCATION OF WATER, STORM, AND SANITARY STRUCTURES AND CROSSINGS PRIOR TO STARTING WORK. 5.THE CONTRACTOR SHALL COORDINATE WITH LUMBEE RIVER ELECTRIC FOR MOVING EXISTING GUY WIRES AND PROVIDING POWER TO THE SITE. CONTACT KAREN LLOYD AT 910-827-2148. 6. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR ALL CONCRETE STRUCTURES, CASTINGS, FILTER AND PIPING MATERIALS FOR APPROVAL PRIOR TO PURCHASING. ENGINEER SHALL HAVE 10 DAYS TO REVIEW INITIAL SUBMITTALS AND 5 DAYS FOR RESUBMITTALS. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING RECORDS AND SUBMIT AS BUILT DRAWINGS FOR UTILITIES AS REQUIREMENT. 8. SOIL BORING LOCATIONS ARE APPROXIMATE. SEE SOIL REPORT FOR SOIL DESCRIPTIONS AND INFILTRATION RATES. Approved Stormwater Permit Documents Construction in accordance with these documents is required by the stormwater permit. North Carolina rules require that the stormwater system designer Inspect during construction, certify conformity with the plans and specs; and certify compliance with the stormwater rules. (15A NCAC 2H .1008 (j )� �` Permit #56 �� I'� 84O Date by -221atp ,4 * NC Division of WaterQuality Sheet Sheet # �._/�.� Revfsion DateQ 4F.+, tL`.�EaS•, C��� r. Y SEAL (33402 KR M^ L o� CL N E C O aco 7 Z ti o c�Nn N L ° C) L O` LL z IV / > T co L � s°rirn 0 W •� V m � or ) U Z c a, 0 M E C: .c a CIA z o It LU N m U z Cr. O •M U Cr 0 Y_ J •4) rUJ � � V � p F- H ii c- W U � a C J G U Q z L.J. J F- D Designed By: BJK Drawn By: BJK Checked By: TSS Scale: Date: 7J2014 Revised: O O O Project Number. 140264 S P-5 IN r, X. SEE SHEET SP-6 FOR ADDITIONAL RETAINING WALL DETAILS AND SPECIFICATIONS 6" ORIFICE OPENING INV. 254 8" MASONRY BLOCK FILLED WITH CONCRETE 253 STORMWATER , ," BASIN ��t4 #4 HORIZONTAI REBAR 15" C/C 4" CAP STONE / BLOCK #4 VERTICAL BENT REBAR 18" C/C ALTERNATING SIDES FILTER MEDIA �2' 3000 PSI MIN CONCRETE FOOTING STORM FILTER RETAINING WALL DETAIL N.T.S. DONCITE 180 JOINT&CM" TFBRJ 6SPANSIONJQNf' FIKL FBLALLCEUS PAQWOR WAMtPXN1NG I . ;`-„IZ AaAMMa AFk1tlKWO FAK L70N1RCY.JOf4T1 SPAC7VCi ONVBfRrlIL1P8+Yk3RCBr�ITR7 VARY AfM CVNAIX.110 FIIM11IM TOALL WALLSTEP00%INSOrAPitERF FxPAN39OFIJC]Ig6 - _ RffAH rG WAU COMT L JUNT +SCALE NM DQNtiIE7)!IF.7�D IONf/tT ' TitRITF.IB+ANS4CJ14 JLk1YI' FItL AlLC6Li � YI10V8IFABRIG F 57 ROD RES[94i f'C]RI�AIIK'AEAIPITJ� SPACING ON VEMrAL WOORCIA0If 70 VARY PbEDIMAQ VERITCAL J01mr SCALE: REOWORCffiS'ta� CONCRETEJi1ASaMARY 1. BARS SHALL BE ROLLED FROM NEW ULET-SiF.Et. CONFORMING TC)'SPLCWCATIQN .;IiTUN91S COMORMP(G 70 1. CONCRETE MASONRY WVI S (CMU) SHALL LE LJGHITNW- I- TFIE CC3NiRAC70IR SFtA[L 8E RESPONSM3EE FOR REVEWM4C ALLDPAENSKNaN TIE FOR DEFORMED REE1-MM SARS FOI? CONCRETE RI CEM M.' ARM A6i5 ASTM C90 WUN A PRISM Si1RENGTH OF 1800 PSI DRAWI M AND ADVISING 7W ENGINNEER OF ANY GFFERENCES INTFE ONE NSEW GRADE6LL 014 THE DRAWINGS PRIOR TO COMMENC84G CONSTRUCTION. 2. MORTAR SHiAU BETYPf S TFIBC)IJGJiOif( 2. DETAIL AND FABRICATE REIWORCING STEEL IN ACCORDANCE WISH 7NANUAL OF EXISTW6 CSMIAIIIt7NS STANDARD PRACTICE FOR DETA04GREIWORCEDCONCRETE' MRUG7URE$'ACIST5 3. ALL CS.LSSHAELBEPOURB}SOLDWITH 30CJ(3PSICOWIMEWITHPIEAGRAVEL pGGREAZE, 1. THE CONTRACTOR SHALL BE RESPONSWE FOR PXVVA24G ALL O SING JOB 3L REINFORCM STEEL SHALL BE IN PLACE AND REVIEWED BY 1WE ENGINEER PRIOR TO I CONDITIONS! ANYADVERSE E)iLSTIt4G CONDITIONS ARWWJG WORKK SHOWN ON PLACENGCONCRETE 4, ALL HORIZONTAL BARS SHALL BE RdWANY.CHANNEL ORLd4MMOCKS. THESE DffAStM$SHALL BEBROUGHTTOTHEAn NIMOFMEEMNERTOR POSSIBLE CLARR#CADON OF RECXINCILIATIOAL 4. FABRICATE BARS IN CONTINUOS FOOTINGS WALLS, AND TURNED DOWN SLABS TO 5. WALLS SFIALL BE ACCURATELY LAID OUTAND. CWtRtfCW SO THATNO WALL LONGESTPRACTICALLENGTHS, VARMsMORE THAN 114" FROM ITSDEVIONATEDLC)CAiiON.THIS VARIATION LNIT eONSi)tI�i101tgAt£1Y SHALL APPLY TO WALL PLUMBNE,SS AND WALLSMAC411NESS. 1. TWE DRAWINGS DO NOTCONTAIN 7FE REQUWA484MFMJOSSAFETY. ALL 5. LAP REBAIR SPLICES A MW NUM OF40 BAR DIAMElEIR$ BLIT.AM0&4UM O16 24" PLAN REBAR SPLICES TO OCCUR ATPOINIS Cf MLNIW UM STRESS UNLESS OTHERWISE & ALL BEID AND HEAD JOINTS SHALL BE FULLYMORTARID. P8<",IONS SHALL BE RESPONSM07YOFT1ECONFRACTOR. SFKi1A9+L Z WFJEN HORIZONTAL JOINT REKTORCEMeOIS SPECM, RENfORCE1vtiB4TSHALL BE 66 TERMINATE CONINUOLJS BARS IN WALL F00104G5, WALLS, AND RI REED DOWN #9 GALVANIZED TRUSS TYPE HORWONTAL .tOWRO ORCEMIENI SPACED AT8" OC SLABS WTfH A STANDARD 90- DEGREE HOOK AT DISCONTWLIOUS END& C'ORNEK VERTICALLY FOR BOTH A OWAND BEt.OW GRADEMASONRf : LAPAEL AND LNIERSEC7ONS REIWORCEMENTJOINTS A MNI IUM OF IT. 7: AT LOCATION $ REQU"iG VERTICAL DOWELS INTO} FOOTNGS� 7HE PLACBNENTOF THE DOWELS 5HALLMATCH THESTZEAND C1ASrAYMATC}/71lELOCAMM OFTHE VEKACAL WALE RFBARS REQUONG THE DOWELS. DESF6N CpN'CRIOhii B. ALL DOMW SHALL TERMINATE N THE FOOTING VAM A STANDARD AC144 DEGREE HOODUN?.M3iPECffCALLYSHQWNa7F##IWLSE DOWJ3SSLi41J_LAPTI MR I. DESIGN EARTH PRESSURE =120PCFAND EFP=45PSF,SOLEfJCT10N MATCNJNG VERTICAL REBAR 40BAR DWdETERS ORAMNIMUM OFZC ASSUAIM = 0.40 (F=O. 7AN0j, ANGLEOFINWRNAL FRICTION ASSUMED TO 8E 32° 9. UNLESS OINERWISENOTED ONTHE DRAViIIINGRFRARSSMALL HAVE TFIEFOLLOWING MINIMUM CLEARANCES FROM THE FACE Of CONCRETE 2- BACK FILE SLOPE TO BE MAMUM Of2:1 W1IH NO SIIRCHARGEADDED Al FOO7M4GS 3-VATH &UlH fORMS 2"rRF JOVABWMRJNS 3 ASSUA$"D BE.4RX+IG PRESSURE = 2000 PSF (ICJ tE F1BD VERFiD BY fo. SUBMff SHOP DRAIliI FOR APPROVAL PWR70 FABRI ATCK ENGINIEEM• 4. SLU MWG IS PRESUMED -fo BE RESISTED BY BOTH PASSNEPRBSUREAAD FOUNDATIONS FRICTM S. THE RESULTANT OF THE FORCES PASS TTM MIDDLE TO Of THE 1. ALL FILL SHALL BE CLEAN SELECT MATERIAL FREE OF DELETERIOUS WALL FOOTING. MATERIALS SUCH AS WOOD ROOTS TRASH OR OTHER EXTRANEOUS MATERIALS. PLACE FILL IN 8 INC LIFTS MEASURED LOOSE AND COMPACT EACH THE OVERTURNING SAFUY FACTOR IS 1.5 OR GJREAIER. LIFT TO 90% MAXIMUM DENSITY AT OPTIMUM MOISTURE CONTENT AS ME4SUREDBYASTMD-698. 71 SSW SAFEW FACTOR IS15OYRGRE47IRV1104OUTANAWIFING 2. FOUNDATIONS SHALL BE PLACED ONLY ON APPROVED NATURAL SLAB FOR PASSIVE RESATANC IE UNDISTURBED SOIL STRATA OR ON PROPERLY PLACED ENGINEERED CONTROLLED COMPACTED FILL UNDER THE SUPERVISION OF THE ENGINEER. 3. FOOTING EXCAVATIONS SHALL BE APPROVED BY THE ENGINEER PRIOR TO PLACING FOOTING CONCRETE. 4. FOOTING ELEVATIONS SHALL NOT BE RAISED OR LOWERED UNLESS SPECIFICALLYAPPROVED BY THE ENGINEER. 5. FOOTINGS MAY BE CARRIED TO LOWER ELEVATIONS WHERE DIRECTED BY THE ENGINEER. CONCREM 1. CONCRETE SHAM DEVELOP THE FOLLOWENG MROM UMI C7Ok�55KE STREICTHS AT 26 DAY& A) MUNGS-3000PSI B) FRL FORMASONRYUNM-3i00oPS1 C) AM07MMCONCRETE -XWPST 2. CONCRETEFCIRFALNCONCRETEMASiONRYBLOCKCRISANDOVERMASONRY IBIBIS SHALL BE PEA GRAVEL CONCRETE MORTAR MN WILE NOT BFALLON� FOR ANY BLOICKMAS0WYfU REQUlREM64M S. CONCRETE TO BE PERMANENTLY EXPOSED TO Vffi ERSHALL MVE5R AN ENiRAILMF.N E, 4. ALL C0L4CRETE WC; RK SHALL. CONFORM TO'IUILDM C ADERfQl.I IlffS FOR R RCED CONCRETE*Aa3l& 5.011SERVEALLANDSTRJCILYFOUAWAMACISIMAND�V6RR7E iHVIS 1�EC71VEEYFMPROTECtiaVOFCONCRMNJWAWCOLD WEAUM & ALL C 4C'REM WORK SHALL BE PROPERLY CURED MVO WBHACI30B. Fa HM WATER C.MOU OR SFMIM MAi6RbgL.8lNETHOLJMAYBI U$M PROVJl,7� TFLAT THl: METHW CHOSO4 HAS NO DE1RIkA84TAL 0fECiONTFEFJLINL nYM SPECOW TOR THE RESPECTMEAREAS. FILL aOLIARD WTH CONCRETE WIN 2500 PS i /( CONCRETE .-/- _-_.-__---t- GROUND LEVEL <. !OR PRODUCT INFORM AtiON AND CTJE INFPRECAST. CONTACT JENSEN PRECAST. STEEL PIPE BOLLARD DETAIL (NTS) DIAkETER HEIGHT q" T50 LaS. 6" �00 85. 8" 500 LdS. 1D" BDD tBS. r7' _ r.roo I.as SPECIFICATION LEGEND: RETAINING WALL: MANUFACTURER: FAY BLOCK MATERIALS CONTACT: KEVIN McMILLAN MAIN OFFICE: 910-323-9198 MOBILE: 910-987-55299 SIZE: SEE DETAILS COLOR: A905M STONECUTTER MORTAR: 902 HARVEST MOON/LAFARGE 470 BRICK ROWLOCK & EXPOSED BRICK COURSE UNDERNEATH ROWLOCK TO MATCH ADJACENT BUILDINGS. FELT JOINT: 1/2" BLACK FELT EXPANSION JOINT (TYPICAL) (DO NOT SUBSTITUE WITH WHITE FIBERGLASS EX. JOINT) (TYPICAL) SCORE LINES: HAND SCORED (TYPICAL) 4" CONCJlE I L 3000 PSI MIN 3, 4" CLEAP!OUTS \ BLOCK FILTER WAIL � TOP ELEV-255.5 6" ORIFICE OPENING ELEV=254 (5 TOTAL) 10" WASHED SAND STONE WRAPPED II'J ADSORB -IT FABRIC" 600 SF SURFACE AREA 12" ERFt: BOARD -IT FABRIC AS MANUFACTURED BY ECO-TLC, INC GIG HARBOR V;:�\ -- INTERCRAL CONCRETE CURB 2.0% ELEV=255.5 18" PONDING -NONWOVEN BLOCK RETAINING WALL TOP ELEV=L56.2 TOP OF BANK GEOTEXTfLF sE are ° 71orJ FABRIC Fo SAND LAYER *ADSORB �----12" ?SI WASH;--D STON`r 4' PERFORaIED PVC C;rh 91' (jr /TYP/ 1 TC RISER OUTLET STORMWATER FILTER DETAIL (NTS) COMPACTED EARTH SUBGRADE TO 98% TYPE C CONSTRUCTION JOINT SLOPE � VARIES 4 CONCRETE DRIVE INVERTED CROWN TYPICAL SECTION BUILDING - BUILDING SLAB/FGUNDA iION TYPE A EXPANSION JOINT ALONG BUILDINGS Approved Stormwater Permit Documents construction in accordance with these documents is required by the storrrn+ater permit. North Carolina rules require that the stormwater system designer Inspect dudng construction; certifylcon� with the with the plans and specs: and certify compliance siormwater rules. (t 5A NCAC 2H .1006 (j) ) Pe. mit # G If O � Date by INC Division of Water (lualfty, Shoat #Revision Date ff • �L fit% to MCL rkn o co ' J. � v N O (n L Z � oe N 0 Q >` � C X LL Z J •� V • � m rn rn W U � i71Y, pil z J a--r Q -a U 0 Y CC _ Y •� W � a oc 0 � � U J :3 GS. J G U a � (Q 1- W 0 W Designed By: BJK Drawn By: BJK Checked By: TSS Scale: V = ao' Date: 7/2014 Revised: O O O O Project Number. 140264 14MOVi