Loading...
HomeMy WebLinkAboutSW6091001_APPROVED PLANS_20091207STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW &(/�1�� DOC TYPE ❑ CURRENT PERMIT APPROVEDPLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD 116 N. Cool Spring Street Fayetteville, NC 28301 Voice 910-221-0033 Fax 910-221-0035 www.crawforddsn.com Crawford Design Company C Copyright 2009 All drawings, specifications and designs prepared by Crawford Design Company are instruments of service and shall remain the property of Crawford Design Company. The Owner or any other parties shall not use the work on this or any project except by a proper agreement and appropriate compensation. SEALS �7rAO�o OES IGH i O� Norl,,, cOy'Y Q 9 T a T ogrH Cqq�� G. qr �jp��EV I LLE �'- DES IGN"vI �nCFRT V A CAH " G. 9h rI��TEV ILLS• 31804 VICINITY MAP (N.T.S.) STEDMAN PENTECOSTAL HOLINESS CHURCH STEDMAN PENTECOST FAMILY LIFE CENTER PROPERTY INFORMATION Rropt�r Idni#Icbf�n;Nu(nber :3 0495-07-0403, 0485-97-5327, 0485-97-4307 fa�rtydr§i Lcatwn 432 Hillsboro Street, Stedman, NC Located at the comer of Hillsboro Street & Azelia Drive GENERAL NOTES ALL GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND OTHER INFORMATION INDICATED ON THIS SHEET SHALL APPLIED TO ALL CONTRACT DOCUMENTS AND SHEETS IN THIS SET. 1. THE GENERAL CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AT THE JOB SITE. 2. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE VERIFIED BY THE GENERAL CONTRACTOR WITH THE SURVEYOR OF RECORD PRIOR TO BEGINNING CONSTRUCTION. BENCHMARK IS AN SET IRON PIPE BEING THE NORTH-EAST PROPERTY CORNER OF THE PROJECT SITE, AND HAVING AN NAVD 88 ELEVATION OF 127.56 3. ALL DIMENSIONS AND ALL ELEVATIONS ARE MEASURED TO BACK OF CURB UNLESS OTHERWISE NOTED. 4. THE INTENT OF THE LIMITS OF CONSTRUCTION (LOC) SHOWN ON THE DRAWINGS IS TO DEFINE THE GENERAL AREA TO CONSTRUCT, INSTALL AND/OR MODIFY THE SITE IMPROVEMENTS. TYPICALLY, THE LOC WILL FOLLOW RIGHT,OF-WAY OR PROPERTY BOUNDARIES. HOWEVER, THE LOC MAY BE SHOWN IN CERTAIN LOCATIONS FOR READABILITY AND CLARITY PURPOSES. THE CONTRACTOR SHALL CONTACT THE OWNER'S REPRESENTATIVE REGARDING ANY QUESTIONS AS TO THE EXACT LOCATION OF THE LOC PRIOR TO BID AND PRIOR TO BEGINNING CONSTRUCTION. ALL ITEMS SHOWN ON THESE PLANS THAT DO NOT SPECIFICALLY STATE -NOT-IN-CONTRACT (NIC)' SHALL BE INCLUDED IN THE BID COST, INCLUDING ITEMS THAT MAY BE OUTSIDE THE LOC BOUNDARY. 5. LOCATIONS OF EXISTING UTILITY LINES HAVE BEEN TAKEN FROM UTILITY RECORDS SUPPLEMENTED BY FIELD INSPECTIONS AND SHOULD INDICATE IN GENERAL THE TYPE OF UNDERGROUND FACILITIES NOW IN SERVICE. LOCATIONS SHOWN ARE NOT GUARANTEED. DEVELOPERS OR CONTRACTORS SHALL NOT ONLY MAKE SUBSURFACE INVESTIGATIONS BUT SHALL ALSO ALLOW FOR CONTINGENCIES WHICH MIGHT ARISE BY REASON OF ENCOUNTERING UNRECORDED LINES OR LINES BEING IN DIFFERENT LOCATIONS THAN INDICATED ON THIS PLAN. AT LEAST 48-HOURS PRIOR TO ANY CONSTRUCTION ACTIVITY, EXCAVATION, GRADING, OR DIGGING ON THE SITE, THE GENERAL CONTRACTOR SHALL NOT IFY T ALL UTILITY COMPANIES O VERIFY AND/OR FIELD -LOCATE THEIR RESPECTIVE UTILITIES (THE NORTH CAROLINA ONE CALL CENTER-1-800-632-4949). ALL DAMAGE INCURRED TO EXISTING UTILITY LINES DURING CONSTRUCTION SHALL BE REPAIRED AT THE GENERAL CONTRACTORS EXPENSE- 6- ALL WASTE MATERIAL SHALL BE LEGALLY DISPOSED OF OFF -SITE. 7. A FORMAL EROSION AND SEDIMENTATION CONTROL PERMIT IS REQUIRED FOR THIS SITE UNDER THE REGULATIONS OF THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES (NCDENR). THE GENERAL CONTRACTOR IS REQUIRED TO AND SHALL FOLLOW ALL LOCAL, STATE AND FEDERAL REGULATIONS TO MINIMIZE EROSION AND THE TRANSPORT OF SEDIMENT OFF -SITE DURING, INCLUDING?HE PLACEMENT AND MAINTENANCE OF CONTROL MEASURES. ALL MEASURES REQUIRED SHALL BE INCLUDED IN THE BID COST WHETHER SPECIFICALLY INDICATED OR NOT. 8. ALL PARKING STRIPES SHALL BE 4" WIDE AND SHALL BE MARKED WITH STANDARD WHITE TRAFFIC PAINT. ALL ISLANDS AND TRAFFIC ARROWS SHALL BE MARKED WITH STANDARD WHITE TRAFFIC PAINT. 9. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH ALL TOWN OF STEDMAN, CUMBERLAND COUNTY & STATE REQUIREMENTS. 10. DISTURBED AREAS NOT COVERED BY ASPHALT OR OTHER IMPERMEABLE SURFACES SHALL BE SEEDED AND STABILIZED PER SPECIFICATIONS. 11. ACCESSIBLE PARKING SPACES, ACCESS AISLES, & SIGNAGE SHALL BE PROVIDED BY THE GENERAL CONTRACTOR AND INSTALLED PER FEDERAL, STATE, AND LOCAL REQUIREMENTS UNDER THE AMERICANS WITH DISABILITIES ACT (ADA). STANDARD R7-8 RESERVED PARKING AND MAXIMUM PENALTY $250 NCGS 20.37.6 SIGNS MUST BE INSTALLED IN FRONT OF ALL ACCESSIBLE PARKING SPACES. "VAN ACCESSIBLE" SIGNS MUST BE PROVIDED IN FRONT OF THE VAN ACCESSIBLE PARKING SPACE(S). 12. ALL TRAFFIC CONTROL DEVICES, PAVEMENT MARKINGS, SIGNS, AND SIGNALS SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN COMFORMANCE WITH THE STANDARDS SET FORTH IN THE NORTH CAROLINA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. 13. THESE PLANS INDICATE THE MAJOR DEMOLITION COMPONENTS TO BE REMOVED AND/OR, RELOCATED. HOWEVER, THE CONTRACTOR SHALL DEMOLISH AND/OR RELOCATE ALL MISCELLANEOUS COMPONENTS NOT SPECIFICALLY INDICATED ON THESE PLANS TO PROVIDE A CLEAN SITE FOR THE INSTALLATION OF THE NEW IMPROVEMENTS. 14. SURVEY, BASE MAPPING, & TOPOGRAPHICAL DATA PROVIDED BY BGW SERVICES - (800) 552-7137 15. CONTRACTOR SHALL INSTALL TREE PROTECTION FENCING AROUND ALL TREES WITHIN THE VICINITY OFTHE CONSTRUCTION ACTIVITY SO AS TO PREVENT ROOT SYSTEM DAMAGE. FENCING SHALL BE INSTALLED A MINIMUM OF 6-FT FROM BASE OF TREES UNLESS OTHERWISE INDICATED. 16. AREAS OF SHADED CURB & GUTTER INDICATE THE USE OF CONCRETE "SPILL -OFF" CURB & GUTTER. ( SEE SHT. C5.2, #2) 17. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL & NATURAL RESOURCES & THE NORTH CAROLINA DEPARTMENT OF WATER QUALITY FOR APPROVAL TO REMOVE ALL CONSTRUCTED TEMPORARY & PERMANENT EROSION & SEDIMENTATION CONTROL MEASURES, AND FOR THE APPROVAL OF PERMANENT GROUND COVER. 18. CONTRACTOR SHALL INSTALL A RAIN GUAGE AND MAINTAIN A MONITORING LOG ACCORDING TO NCDENR REQUIREMENTS UNTIL THE AGENCY HAS RELEASED THE SITE. 19. CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL ACCORDING TO NCDOT REQUIREMENTS DURING THE CONSTRUCTION OF IMPROVEMENTS IN THE RIGHT-OF-WAY. AL CHURCH Rev. Randal Stri kland - Stedman Pentecostal Holiness Church 432 Hillsboro Street - tedman, NC 28391 Ph.: (910) 483-2611 x.: (910) 483-8058 LEGEND / KEY ABBREVIATIONS ,.. .., .. ._ ,.....z".., s..t .'„":' ii.. ,. roi..v ,xwx .,.< R .a t.fi ram.,, � X •. .r.: Ya ..... 1 v ...: .. A. I"r. :. ....n % . . e eYJ, v: ' ro e .. w,. .�.. >t . , r%.. �„ . .. N Egli . _, �,.... ,. , r _ . , .. � .... ,,: x..,..r � :.I,, P ,1 , -`.: a, I .. .% a X §tiNLT. .,. , /,,..,.: �, 1, rt tl n � r I 4 . D§tt$ i t tan; t41� itt3tYiit`,,€ �,y�a', N�Ni .,>v .,,,,,. � .�s ,�%,.-�._.a., �..... H I t �i bas,c b a ,t,....,a N q�.... .r.Abb�tet+iaf bri,,,�... �E .._... �p '� .'}+,.�.v,�v_Y�''a^�, ..kk*�,...�.ir:.tt.<m..2"a;� c.z� ... ... .;rTni., .. ., �....,... ,. _:....s AD,�.r�V �t C 1-�'�w +� r�e2,€ q P.H (, ,c..') ',�... .,,t'm'�#':w :�'r ,r,.,..r +a,....� .s.;Y*lu�, CABLE/TELEVISION CA CA NOTE BUBBLE (GRADING) N/A A/C AIR CONDITIONING L LENGTH, LEFT CENTER UNE — — CONTOUR LINE — — —100— — — —900-- ADJ ADJACENT LF LINEAR FOOT NOTE BUBBLE (SnE) N/A O DIVERSION BERM N/A --*-- OB "-F AFF ABOVE FINISH FLOOR LET LEFT EASEMENT — — — — - — — — — ` — - NOTE BUBBLE (UTILITY) N/A O AL AREA LIGHT V FENCE X X FIBER OPTIC FO FO W APX APPROXIMATE MAX MAXIMUM FORCE MAIN FM FM PLUG T ASBY ASSEMBLY MIN MINIMUM NATURAL GAS G G .. .. ... ASPH ASPHALT MISC MISCELLANEOUS LIMITS OF CONSTRUCTION N/A LOC 1...1.' ..t.... - OE OE POROUS BAFFLES NIA AUTO AUTOMATIC MON MONUMENT OVER HEAD ELECTRIC PROPERTY LINE PROPERTY LINE (ADJACENT) 0— — — ---0 NIA B.O. BLOW -OFF NIC NOT IN CONTRACT RAILROADTRACKS �- PDST INDICATOR VALVE B.V. BALL VALVE NTS NOT TO SCALE RIGHT OF WAY R/YV RAW GANITARY SEWER—4 5---4— 14 Sdo POWER /TELEPHONE POLE -o- -•- BAIL BETWEEN SEDIMENT FENCE N/A SF BEE BELOW FINISH FLOOR O.C. ON CENTER SLOPE DRAIN N/A --0— SPD REDUCER/INCREASER —.-- BLDG BUILDING O/N OVER HEAD SLUDGE RETURN LINE SR SR STORM DRAIN --4— SD �—' ' 4 SD �� RIDGE LINE N/A 4 BOQ BACK OF CURB V — - - — — - - — V P POINT OF CURVATURE SWALE/DRCH LINE � •/ � BOW BOTTOM OF WALL C TELEPHONE T T BX BOX PI POINTOF INTERSECTION UNDERGROUND ELECTRIC UE— —UE— ROCK DAM/WFJR N/A PIV POST INDICATION VALVE WATER W w CF CUBIC FOOT PP POWER POLE _ ROCK PIPE INLET NIA CI CURB INLET PT POINT OF TANGENCY ASPHALT PAVEMENT PROTECTION (STANDARD) [ — — — ] CL CENTER LINE PVC POLYVINYL CHLORIDE ASPHALT PAVEMENT (HEAVY NIA - - - SIGNAGE CMS CONCRETE MONUMENT SET PVMT PAVEMENT Du CMU CONCRETE MASONARY UNIT CONCRETE _ — — TELEPHONE PEDESTAL M CONIC CONCRETE R RADIUS, RIGHT N/A Varies CONSTR CONSTRUCTION R.J. RESTRAINEDJOINT GRASS/SOD ..................................................... RIGHT OF WAY HR a CONTR CONTRACT OR RN1I TREE/S U GRAVEL RCP REINFORCED CONCRETE PIPE [ � CTI CAST IRON GRAVEL CONST. ENTRANCE N/A TRENCH DRAIN CY CUBIC YARD RDCO ROOF DRAIN CLEAN OUT NAMM — — — _ RED REDUCED PAVERS WATER METER/VAULT ■ D DEPTH REM REMOVE L - - - - - - - 1 0 SEDIMENT TRAP N/A WATER VALVE DEMO DEMOLISH(DEMOLITICN) RNF REINFORCE DI DUCTILE IRON RQD REQUIRED SOIL — _ N/A WHEEL STOP C - = C O DIA DIAMETER RQMT REQUIREMENT V VELOCITY DISSIPATION/RIP gUL-- ® ® DIM DIMENSION RT RIGHT RAP PROTECTION js3 {>( YARD INLET ■ ■ DWG DRAWING RWM RIGHT OF WAY MARKER W L• -J L'---__-J ECM EXISTING CONCRETE MONUMENT SCH SCHEDULE EIP EXISTING IRON PIPE SD STORM DRAIN EIS EXISTING IRON STAKE SDCO STORM DRAIN CLEAN OUT ELEC ELECTRIC (ELECTRICALLY) SDMH STORM DRAIN MANHOLE 7 _ ELEV ELEVATION SED SEDIMENT L �/ ACCESSIBLE RAMP F 4 —1 ELMH ELECTRICAL MANHOLE SF SQUARE FOOT ENCL ENCLOSURE SLV SLEEVE W W AREA LIGHT EOC EDGE OF CONCRETE SPEC SPECIFICATION EDP EDGE OF PAVEMENT SO SQUARE C r PREVENTION ASSEMBLY —� —� EQPT EQUIPMENT SS SANITARY SEWER ASSEMBLY 7 BEND N/A ESMT EASEMENT SSCO SANITARY SEWER CLEAN OUT L W �I EX EXISTING SSMH SANITARY SEWER MANHOLE BLOCK & GRAVEL INLET 11 I PROTECTION L®J I N/A EXCV EXCAVATE (EXCAVATION) STA STATION 7 CHECK DAM N/A ; ► ♦- ► ♦ EXT EXTERIOR STD STANDARD L V STOR STORAGE CLEAN OUT —NO--e 0 o FES FLARED END SECTION STSL STAINLESS STEEL W FEE FINISH FLOOR ELEVATION SY SQUARE YARD < CURB & GUTTER FH FIRE HYDRANT U. CURB& GUTTER (SPILL OFF) N/A FIN FINISH TBM TEMPORARYBENCHMARK FLR FLOOR TEL TELEPHONE J CURB INLET wilill IW FNC FENCE TEMP TEMPORARY DROP INLET ® In FO FIBER OPTIC THK THICK Q FOBX FIBER OPTIC BOX TMH TELEPHONE MANHOLE LCL J77 i j--f l FOC FACE OF CURB TOG TOP OF GRATE DUMPSTER UNIT r TI A I''I.I�_QII FT FOOT TOH TOP OF HOOD TOP TOP ELEVATION ELECTRICALTRANSFORMER ® G.V. GATE VALVE TOW TOP OF WALL FIRE HYDRANT ASSEMBLY p-p X GA GAUGE TEED TELEPHONE PEDESTAL �vYO Tr" GALV GALVANIZE TS&V TAPPING SADDLE & VALVE Q FLARED END SECTION GND GROUND TYP TYPICAL I /1 U. V GRAV GRAVEL �/ f GAS METER ® U/G UNDERGROUND GAS VALVE HOPE HIGH DENSITY POLYETHYLENE UTIL UTILITY HORZ HORIZONTAL GRADE BUBBLE 1 OO.00 (TOP -ELEVATION) �' 100.00 HT HEIGHT VAL VALVE GRADE BUBBLE 100.00 HVAC HEATING /VENTILATIING/A/C VERT VERTICAL (FINISH -GRADE) + 100.00 HVD HEAVY DUTY GUY WIRE E-- HW HEAD WALL W/ WITH W/O WITHOUT HARDWARE CLOTH &GRAVEL N!A L IN INCH � ro ted Stormwaier !`"*rrt91A1&tt,INBntR -a O HEADWALL 1� INT INTERIOR IIsB 55tructiOn in accrrdanc2 W+ih Mt 0, METER �r�,QI �lrBd by the Store aleSlOnT pIle e C JUNCTION BOX INV INVERT pylplS require that', Slormwatery�gy� 1§ IC G ISS IRON STAKE SET Inspect during constroc'.icrr, r,Brmp cone With O plans and specs. an4 ca"ih comHpliancge (w)d�h the LIFT STATION OO O `Erormwater rules. (15A N.;AC, 2YAC10- T/ ' ZW L--J Permit # ��QJQ d!pr C Division Fate_- 1 .}.J O O JB JUNCTION BOX b �� NC Uivisien OI Water Qual . MANHOLE JNT JOINT Sheet #_ _ ?.�.+... _ Revision NOTE BUBBLE(DEMOUTION) N/A ❑O .O O A Z _0 U U Z VICINITY MAP(N.T.S.) DEMOLITION NOTES 1❑ DEMOLISH & REMOVE EXISTING CONCRETE �2 DEMOLISH & REMOVE EXISTING HOUSE & ALL ASSOCIATED COMPONENTS ] DEMOLISH & REMOVE EXISTING ASPHALT PAVEMENT 41 SAW -CUT & REMOVE EXISTING ASPHALT PAVEMENT AS NECESSARY TO INSTALL IMPROVEMENTS 5� DEMOLISH & REMOVE EXISTING CONCRETE CURBING © CONTRACTOR SHALL CLEAR & GRUB EXISTING FORESTED AREA & VEGETATION AS IS NECESSARY TO PROPERLY INSTALL IMPROVEMENTS 7❑ REMOVE & RELOCATE EXISTING UNDERGROUND UTILITIES & ALL ASSOCIATED COMPONENTS AS NECESSARY TO INSTALL IMPROVEMENTS. CONTRACTOR SHALL COORDINATE WITH THE OWNER AND THE RESPECTIVE UTILITY PROVIDER(S) PRIOR TO BEGINNING WORK B� CONTRACTOR SHALL COORDINATE WITH OWNER AND REMOVE AND RELOCATE THE EXISTING TRASH REFUSE CONTAINER TO A TEMPORARY LOCATION. UPON COMPLETION OF CONSTRUCTION THE CONTRACTOR SHALL COORDINATE THE PLACEMENT OF THE CONTAINER IN THE NEW DUMPSTER ENCLOSURE Q REMOVAL & RELOCATION OF EXISTING "HUT' BUILDINGS AND ASSOCIATED COMPONENTS WILL BE BY OWNER. CONTRACTOR SHALL DEMOLISH & REMOVE ANY EXISTING FOUNDATIONS, ETC. NOT RELOCATED BY THE OWNER. CONTRACTOR SHALL COORDINATE WITH OWNER PRIOR TO BEGINNING WORK. 10 DEMOLISH & REMOVE EXISTING CONCRETE PADS UNDER & AROUND THE EXISTING DRIVE-THRU CANOPY. CONTRACTOR SHALL INSURE NOT TO DAMAGE THE EXISTING CANOPY & ASSOCIATED BRICK COLUMNS. t 1 DEMOLISH & REMOVE EXISTING BRICK STEPS & WALL, METAL HANDRAILING, AND LANDSCAPE PLANTER BRICKS TO ALLOW FOR THE INSTALLATION OF IMPROVEMENTS. ADDITIONAL NOTES 1. ALL GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND OTHER INFORMATION INDICATED ON THE TITLE PAGE SHALL APPLY TO THIS PLAN 2. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE VERIFIED BY THE GENERAL CONTRACTOR WITH THE SURVEYOR OF RECORD PRIOR TO BEGINNING CONSTRUCTION. BENCHMARK IS AN SET IRON PIPE BEING THE NORTH-EAST PROPERTY CORNER OF THE PROJECT SITE, AND HAVING AN NAVO 88 ELEVATION OF 127.56 s Crawford Design Company © Copyright 2009 - All drawings, specifications and designs prepared by Crawford Design Company are instruments of service and shall remain the property of Crawford Design Company. The Owner or any other parties shall not use the work on this or anv Droiect except by a Droner aweement and annronriatp romnematinn_ --------— r — _ \ \ j//119— — _ — — / C)- 6 6 I r I I X. PARSONAGE /I I X. WOOD 9 RAMP 6 ,� [4 _ � �����/ \ \ \\ EX. ASPH. //\ 1 / Y,9 u �� \ / / \ \ \ PARKING \ \_ _ N_ cam_ �- _ _ BLDd/`\ �170� / /� � \ X. CONC. � ��\ � � v� 2 PAD o �.yo\\ / X EX. WO RAMP / �9� ~� STEPS_ / / / \ �� /ii//J ❑ ❑ I \\ ���o� •° ���(' \� I // is ♦ / EX. BRIC / / ❑ r \ \ / ❑ + \ l� \ / 3 �z---� 0 II \ \ \\ 71 EX. PLAY AREA / ♦ / 1 / — / \ � �� °`� III IIII I / 6 rr9 — \ / 9 / EX. PLAY AREA `,ILUUUIf��� o\\\�\� / o I Illy III/ // \\ j '/(� /+ EX. CO / \�� I I OI I I ❑ ❑ `]` I - ° + + 7j I �I� III —tzo— — _ _/ < / ♦ / FE=122.89 / w II1, IIII \ / /'- / ��` \ �/ I ry/ u�\�.�// r 5 I IIIIIII / / ` / 7 EX. ROMP y.'I I i r / j ,� Z / _ / X. CONC. DI I'l_,II IIIII PAD © / ❑ I I I POLES o Ir="I III / EX. DUMPSTE ❑ fig F . o EX. ASPH. 7 ��� l FE=125.07 I l I sD r l \)\SO PARKING \\ F� a I EX. SANCTUARY J /r \ /s/4 I III _ IIII/ g X. CONC. / / I I C r ' III IIIII © I PAD_LI INV.=113.56- I /III IIIII I ! / \�' ) \ \ / /y 6 I zr EX. CONC. A /III 1' ll/I I I ' 1 �/'1-1 I/ / A. A/C �\ \ / -' / / I I FFE=122.9 I I / N J EX. A D t \ ' O / III �Illl X. SSMH I /` — / \ \ > ^ l Fk I l a/ y //�A \a I I ! / \ / C / '�1 / � / 5 X. SSMH t2o TOP=119.84 / EX. HOUSE I � UNIT (TYP) ro I � I I ly J/ t / I I t q< LC \ TOP=120.62 J C INV.=111.99 (IN) \ ❑2 / A. l / ! /r -- ,. ' \ / I EX. TELE. / \J�3 'Li �' I v�� EX. ASPH. / �� r , / INV.=109.48 IN '-� INV.=111.95 (OUT) ` \ / / TYP ,� \ �/ I I \ �! PARKING � ( ) EX. CF-\ \ \ \ ❑7 I I I \ �' // / / �,\ INV.=109.53 (OUT) TOP=119.67 \�30" CP \ L'M1 �� / II /A- ° 1 / EX. SEEP _ — / FE=125.04 I EX. 10" PVC SS O� / J / \G \ r// / EX slcN p/ii/I n `ti / /// 3 CJ w l 10 s ® o ./ em s\ �I ❑ i 0/ ( / t 7 1 / / r I \ rir / 1\ `O / / y — m/a m i— M/a k 6 w I a I v \ F — FE=125.04 / o M, Cl/a pLC s,� II10.0' \ /I EX. ASPH. E?=119.49 n/ M w \\ ,— PARKING\I�� l \ rir EX. SSMH / �� .ry -, '✓ r TOP=120.5s a / r /ir ( \ / INV.=111.55 (IN) / r' �� �s 1 \r ` �f ♦1/ / / X. U/G ELEC. (TYP) X, INV.=111.50 (OUT) / iw a+ �� \ �'� / �°\ �Q / \� V 3 r / / /I` \ />r/ J`` /// / // / X. SSMH s \ / roP=12z19 \ I o / s rI/ INv.=109.85 OUT \ �� `< / / / X. CABLE (TYP) �. / � / /� (OUT) \ r y 3 / / EX. ASPH. \ \ \ / / // ,U �a / PARKING'I3¢ r CID 01 /VF cq \ r / /'r/� w b/ s, �/ �\\ \\ // /! C14 OE Ar /v 3 I j o p�C S \� \ ilh. ° / j i %/ I y Cons // / / 4i}' F\ �nst u I aCs m CA r / / � � regw C � , plant a 1r S , ,, L r, n 3n the c..SL!/li /OD l / aeri d r CJr[ / /L 7 ZLO n 30 0 15 30 60 120 N / GRAPHIC SCALE (IN FEET) 1 inch = 30 ft. 116 N. Cool Spring Street ♦ Fayetteville, NC 28301 Voice:910-221-0033 4 Fax:910-221-0035 www.crawforddsn.com IN I D DES IGv ° DESIGN 3�0 „ °ro S,A°c` gpl „� °0 0 CERT. No. < � �� CERT. W. < C-136 C-2097 EV I LLE • �. 9`�%EV ILLS, A' nnEEm xnm► SEALS REVISIONS Z) U �U U J V) W F..,. Z v) JO oU W Q O �. LJ ce LU �— Z 7 L LULU U 0- Q LU J CQ0 LU LU �� V) V J L.L. PROJECT DETAILS PROJECT MANAGER: AMH DRAWN BY: RGM APPROVED BY: AMH PROJECT NUMBER: 09007 SCALE HORZ.: 1" = 30' VERT.: N/A ISSUE DATE 11 /24/2009 SHEET NUMBER C100 7 VICINITY MAP(N.T.S.) o 71g� c Crawford Design Company © Copyright 2009 - All drawings, spl \/ \ / j INV. =113.5 Crawford Design Company are instruments of service and shall remain the property of Crawford Design Company. The Owner or any other parties shall not use the work on this or any project except by a proper agreement and appropriate compensation. 7 \�\ \ 119 14 It 2 / max, HOW. CLOTH & GRAV.- m 121. 4 \ WEIR LENGTH=4' BASIN DEPTH=3' CID\ <3 \ \ BASIN RADIUS=12' WINE lizal 116 N. Cool Spring Street ♦ Fayetteville, NC 28301 Voice:910-221-0033 ♦ Fax:910-221-0035 k \ xA \ I ` 7 1 �1 \� DW. CLOTH & GRAV.-2 www.crawforddsn.com 1 ww_ 12 .16 rNo \ !!8 1 °9 S 4 \ \ WEIR LENGTH=4' d BASIN DEPTH-3' LJ Ns \ \ \ I \ \ \ NNAMED STREAM w W �wuy4 + )J BASIN RADIUS=21' w DESIGA DESIGN 4 N> VL\ \ \ 30' BUFFER PE DWQ REQUIREMENTS y 1 ' \ \ \ �\ \� / c�i CERT. No. CERT. No. 'Zl: i GRADING / EROSION CONTROL NOTES N� ` 121.9 I \I !?! 5 \ \ '` �' 6 / / 3 C-136 g - C-2097 g Q \ •` i INSTALL GRAVEL CONSTRUCTION ENTRANCE (SEE SHT. C5.0, #5) / \� • Nip K \ krr9 t° 1 X LcA^o`j .n �R'+/ 2 INSTALL TEMPORARY ACCESS BARRIERVILL 3 INSTALL BLOCK & GRAVEL INLET PROTECTION (SEE SHT. C5.0, #10) \\ 121 7 20 \ 1 N \ \ `�, '•� \ \ n11O1 nW 4 INSTALL TEMPORARY SEDIMENT FENCE (SEE SHT. C5.0, #7) \ \ \ 1 \ \ . \ \�\ s E A L s 5 CONSTRUCT TEMPORARY DIVERSION BERM (SEE SHT. C5.0, #6) 7 \ �\ `� \\� _•p B CONSTRUCT TEMPORARY HARDWARE CLOTH & GRAVEL PROTECTION W/ BASIN (SEE SHT. C5.0, #121) I \ / \ 1 \ \\ 1 k \ \ \ 4\` \ N CAR�4'#I 7 INSTALL DOUBLE NET STRAW EROSION CONTROL BLANKET ON ALL SLOPES 4:1 OR STEEPER 6 \ / \ \ 1 1 rJ� ` \ \ \ \\ �\ \ \ \ O (SEE SHT. C5.1, #10) TO EX. \ / \ VL \ - X 60 \ \ 5 77`\\� `�_ �` \� `\ ��OFE \ ^ 1 soco-11 rr � ��. \\ 2 ey e INSTALL TEMPORARY VELOCITY DISSIPATER / RIPRAP PROTECTION (SEE SHT. CS.Q #8 & 9) m / 1 .9 \ TOP O F.G. \S°\ \ ` �v \ \� < I� x \ \ EAL ` 9 CONSTRUCT TEMPORARY SEDIMENT TRAP w/ POROUS BAFFLES (SEE SHT. C5.1, #1 & 2) \ 1 .4 INV.=118.67 8" OUT 121.30 x x x fir- -�,-") x x 10 INSTALL STORM DRAIN CLEAN OUT (SEE SHT C5.1, #9) 11 INSTALL 18" x 18" JUNCTION BOX (SEE SHT C5.1, #8) v SRB kJ /' ' • 10 1 1 \ / / 105 LF 8" PVC O 1.04% \ \\ \ 12 INSTALL STANDARD JUNCTION BOX ( SEE SHT. C5.1, #6 & 7) f 1l s91 74 LF 8" PVC O 1.00% 13 INSTALL CURB INLET (SEE SHT. C5.0, #3) vlas to INSTALL DROP INLET (SEE SHT. C5.1, #4) a TOP=121.34 \ 3 / p c ®0.30 15 INSTALL 18" x 18" DROP INLET (SEE SHT. C5.1, #8) \ INV.=117.75 12" IN 12 / / - / / /• \ \ �. ` ( ) 5g �F 18 INSTALL CONCRETE FLARED -END SECTION (SEE SHT. C5.1, #5) f � INV.=117.75 15" OUT ( ) 13 \ TOP 0 F.G. / `�. i'7• � S . � \ \ i+ / \ DI-10 17 INSTALL CONCRETE LEVEL SPREADER (SEE SHT. C5.3, #5) iN 121.34 ,/ SDCO-2A / \ \ INV.=116.67 (8" OUT) / \ TOP=121.05 18 CONSTRUCT WET POND PER DWQ REQUIREMENTS (SEE SHT. C5.7) I �� r / TOP ®F.G. -1�g� \ / <' \ INV.=117.58 8" IN ` \ "+ ,/• INV.=117.93 (8" IN ADDITIONAL NOTES / q 1 , /" \ INV.=117.53 (12( OUT) I � INV.=117.93 (12OUT) 1. ALL GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND OTHER INFORMATION INDICATED ON N I \ / \ \ \�,/ „� 1 O 7 1 \ \ 4 THE TITLE PAGE SHALL APPLY TO THIS PLAN 2. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE VERIFIED BY F \ \� 5 77 THE GENERAL CONTRACTOR WITH THE SURVEYOR OF RECORD PRIOR TO BEGINNING I /• \ rN -� /• <J?� \ �` \�` \ CONSTRUCTION. BENCHMARK IS AN SET IRON PIPE BEING THE NORTH-EAST PROPERTY 1 •/' \ o + \ °B \�- \ CORNER OF THE PROJECT SITE, AND HAVING AN NAVD 88 ELEVATION OF 127.56 1 I \ ---'o -'- \ 1 1 • ' LC\ !7 \ Sk \ \ \ \ /•" k ••k �' �•'•®\ B \ ��\ \ \\ 3. PURSUANT TO G.S.113A-57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO X REVISIONS � � � / rNo ` �./ \ rr \;' !S\ \ °° \ GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR OTHER - w / v k \ /• \ _ ^� ADEQUATE EROSION CONTROL DEVICES OR STRUCTURES. IN ANY EVENT, SLOPES LEFT M 1 .5 / / ) ` EXPOSED WILL, WITHIN 21 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING BkE I 11 0 121 52 21.0 l rhos ` /• \ \ \ ` ' 1 1"2 �,..:-• ; " \ 9 \ \ °>e \ \ \ PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY OR PERMANENT GROUND COVER, f * J kr I O r kr /' \ rNo FAMILY LIFE CENTER ADDITION \ \ •\' \ \ \ \ \ DEVICES OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. PURSUANT TO G.S. 113A-57(3), m IrN Ni a \ d Nyy /•� '6s FFE=122.35 \ /. \ PROVISIONS FOR PERMANENT GROUND COVER SUFFICIENT TO RESTRAIN EROSION MUST ACCOMPLISHED FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR 90 CALENDAR I , s _122' /• \ DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. ALL SEEDED AREAS WILL BE FERTILIZED, RE -SEEDED AS NECESSARY, AND MULCHED ACCORDING TO SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A \\ \ \ / VIGOROUS, DENSE VEGETATION COVER. IF ANY SEEDING FAILURE OCCURS, THOSE AREAS ` I \' o �••� ; o\ SHALL BE RE -SEEDED WITH RYE GRAIN FOR TEMPORARY STABILIZATION AND PREPARED FOR ' PERMANENT SEEDING. 1 j \ 5I ./" i >'p ,Crr.9 4. SEE DETAIL SHEETS FOR EROSION CONTROL MEASURES &MAINTENANCE. 1 ram. m ■ R k X ' / / ss � 5. CONTACT PERSON: RANDALL STRICKLAND - STEDMAN PENTECOSTAL HOLINESS CHURCH - \ \ CI-2 (910)483-2611 V ,( \ "04 _ TOH=120.80 / " - _ - \ /•� 6. PARCEL IDENTIFICATION NUMBER(S): 0495-07-0403, 0485-97-5327, 0485-97-4307 1 III -INV.=117.45 (15" IN) /' \ JB-5A 7. CONTRACTOR SHALL REMOVE TEMPORARY EROSION CONTROL MEASURES ONLY AFTER ry m ,n \ / INV.=117.45 (15" OUT) k \ X TOP=121.95 / REMOVAL HAS BE APPROVED BY DENR. ^ x may/ 1 u . J�3 �} INV.=116.91 (8" OUT) X 8. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING EROSION AND SEDIMENTATION sX / CONTROL MONITORING ACCORDING TO NPDES PERMIT REQUIREMENTS. j x o: \ krN \ \ >1 •/ JB-3A kr Nr' JB-4A ''No' �• �{ N N ,/ N TOP=121.95 9. SEE SHEET C5.0 FOR TEMPORARY & PERMANENT SEEDING REQUIREMENTS. Im -° �"1'+� ! 'o \ { TOP=121.77 { '15 LF 8" PVC O 2.92% 10. TOTAL DISTURBED AREA IS APPROXIMATELY 4.0 ACRES ��, _ ` / INV.=117.39 (8" OUT) 'r INV.=117.26 (8" OUT)` \ TIE T EX.-^ y tRRR6 1 13 3 / 21 LF 8" PVC O 2.15% 1 15 LF 8" PVC O 2.93% 12 1. / 15 LF 8" PVCi .i EROSION CONTROL CONSTRUCTION SEQUENCE 1 J* " I 1 0: 5®1.oa% 1zo ao 1. OBTAIN ALL NECESSARY PERMITS AND APPROVALS AND HOLD PRE -CONSTRUCTION CONFERENCE. 1 ` i? 120.95 �� 11 ��• // ,/ /•/• ,/ /' ./ /,/ •/' /•/• •/ / /•/ /• /"•/ 2. INSTALL GRAVEL CONSTRUCTION ENTRANCE. 3. INSTALL BLOCK AND GRAVEL INLET PROTECTION. <F 7g+ 11 "r`> '' r it • Z 4. CONSTRUCT TEMPORARY DIVERSION BERMS, SILT FENCE AND HARDWARE CLOTH & GRAVEL OUTLET y ' RC 3 2 r • .. I I I r A f f r' I12 1. is I 11 3Q 1 1. X I 1 I 8 I AS AREAS ARE BEING CLEARED AND GRUBBED. I 1 1 95 O I I `' rN 3 I 12 .6 5 CLEAR AND GRUB THE SITE WITHIN THE LIMITS OF CONSTRUCTION. m \. 1 JB-6A Cl-8 \ 0 TOP=121.31 TOP(24\ ® " I INV.=115.48 (8" OUT) \ \ INV.=113.69 (24" N)) \ \ INV.=115.14 (12" IN) \ \ INV.=113.69 (24" OUT) :8s \ \N �Izp TOH-120 74 to \ 7 rrm \ . y A/ T U �/ T D r _ U J r 6. REMOVE AND RELOCATE EXISTING BUILDINGS ON SITE. 121.45 m 1 1 �" ,1, s ? • 1 •1 :11 1 krNo INV.=113.79 (24" IN) \ \ U J W � 7. APPLY TEMPORARY SEEDING TO ALL DISTURBED AREAS AND APPLY EROSION CONTROL BLANKET TO 0 k 'eINV.=113.79 (24" OUT) ALL SLOPES STEEPER THAN 4:1 AS INDICATED ON THE PLANS. I Q2 1 1\ �a• 1 2 64, LF 15" RCP O 1.74% 3 s•1 59 LF 15" RCP ®•1.74%• '� 14 1 ; 'j,�•/ 14Syr,,,' 1 0 \ \ rNov o \, N 8. ROUGH GRADE THE PROPOSED SLABS, PARKING, AND DRIVEWAYS. - V 9. INSTALL STORM WATER UTILITIES. STORM DRAINAGE SYSTEM WILL BE CONSTRUCTED SO THAT 1 •' k , ' - f' 139 LF 24" RCP O 0.17% L U 81! • � 9D SD -SD- !D 9D 90 1 n/ r 122.00 L Jl 1 .09. L \W Wes' -SD -SDI -SD W W Lf PERMANENT DRAINAGE OUTLETS RELEASE RUNOFF INTO THE STORM WATER DETENTION POND I Nr 1 2.40 1 2. 14 I 1 1.69 14 1ti2 61 LF 15" RCP O 1.75%`.. ....• 13 / \ Z WHICH WILL ACT AS A TEMPORARY SEDIMENT TRAP. f "pN 22 00 .J V / 10. INSTALL BLOCK AND GRAVEL INLET PROTECTION AT NEW STORM INLETS. 21. I ! :1 1,\ 11. INSTALL TEMPORARY VELOCITY DISSIPATER(S) AS SHOWN IN THE PLANS. 1 I . - 'l k \ \ 121. \ 3 O Z 12. INSTALL LEVEL SPREADER 1 I a n 1 +, ,.I I ' 1 ✓ 1 .3 \ O 7 13. INSTALL WATER AND SANITARY SEWER UTILITIES. I 1 r r ,U.1 I.. "_ 1 1. 5 / L _ \ = V 14. INSTALL CURB AND GUTTER AND CONCRETE SIDEWALKS. 1 f q m _ ..'•! -122 k h rrrt rtnnnnTrtrr Ir •• I • • . N:' DI-6 15. INSTALL PAVEMENT IN PARKING AND DRIVEWAY AREAS. 11 _ l� 1I I I I111I I I I I I I I I I I I I I trla x \ \ II lz L G� -- Illl IIIII IITIIIII111IIIIIITrtlll 11 I µunnri'rrlrnn rr -(� •'I:' •jam' TOP=121.58 \ J W O 16. CLEAN AND FLUSH STORM PIPES. NI • : G==i I I I I I I I I t I I I I I I �- ' j', 12 , ? .,- INV.=114.02 (15" IN) 17. REMOVE TEMPORARY SEDIMENT TRAP UPON APPROVAL BY NCDENR I 1 / C.F�JLLL.r.LLFLLL _-� 18. APPLY PERMANENT SEEDING TO ALL DISTURBED AREAS. I I 1 / / ! INV.=115.03 (8" IN) 1 1 2 .9 ./ ./ ./ / - / 9 / LJ1 LJ F-a / F •'Ir. LE INV.=114.02 (24" OUT) 19. TEMPORARY MEASURES SHALL BE REMOVED AFTER APPROVAL FOR REMOVAL OF ALL TEMPORARY - - `- EROSION CONTROL MEASURES BY NCDENR HAS BEEN OBTAINED. %1; -' N i FE=125.04 FE=125.04 / • •r /. / /. / ���\� 1-0 m Xr TOP=119.31 TOP=121.90 I IOC NN INV.=117.23 15" IN) INV.=116.11 (15" IN) u r TEMPORARY SEDIMENT TRAP NOTES I TIE TO EX.- 1 b'N - -- -- -- 3` I INV.=117.23 (8" IN) INV.=116.81 (8" IN) FE=125.07 1 r­1 -Nr 1. THE TEMPORARY SEDIMENT TRAP WILL BE CONVERTED TO A STORM WATER DETENTION POND. ALL I I II \ 1 �� INV.=117.23 15" OUT INV.=115.11 (15" OUT) FE=122 89 L J UE IUE UE- m TIE TO EX. ( ) SEDIMENT DEPOSITED DURING CONSTRUCTION MUST BE REMOVED, EROSION FEATURES MUST BE I £ ml '" . / DI-5 REPAIRED, AND THE VEGETATED SHELF MUST BE RESTORED, BEFORE OPERATION AS A STORM WATER BMP BEGINS. TOP=122.00 2. A MINIMUM OF 6-INCHES OF BOTTOM MATERIAL (BELOW THE DESIGN BOTTOM OF THE II I y II - 4c Xr r INV.=115.08 (15" IN) L J \�\\ ORIGINAL SEDIMENT & EROSION CONTROL DEVICE) MUST BE REMOVED PRIOR TO I f I /� \ m Q \ / INV.=116.46 (8" IN) \� \ CONVERSION OF BMP .' \ ��1(� � INV.=115.08 (15" OUT) O J \ \\\\\ Lac - BUILT UPON AREA CALCULATIONS �Ir 1\ \ \\ L - TIE To Ex. -- _ u__ - / rP, 0 / ON SITE DRAINAGE AREA = 2.66 AC = 115,870 SF II \I� N > \ I TIE TO EX. 1 \ EX. SANCTUARY EXISTING IMPERVIOUS AREA = 0.17 AC = 7,405 SF II vO 1 I PROPOSED IMPERVIOUS AREA = 1.49 AC = 64,904 SF It 1 \ i / /I TOTAL IMPERVIOUS AREA = 1.66 AC = 72,309 SIF II C II \ I. -122- - / DENSITY FACTOR = 1.66 / 2.66 x 100 = 62% 1 III n k - - FFE=122.9 rN I f 1 IN - - _ y9/, <^> / INN II X X II 'I m p N 1 �� /^ N 1 1 II . / � /. / I' / \ / r � TIE TO C1 ------ It� I a / 1 V Nip N I 1 / x l I1 EX. ASPH. I PARKING � o �z V 20 0 11 20 40 80 110 0 1 r I \\ \ // _ \ I - I,i / \ \ EX. ASPH. GRAPHIC SCALE IN FEET) 1 inch = 20 ft. 1 \ - PARKING ' s' 1 1.3 \ s \ O Z Q v \ W Cie z 1 1.4 U / W Z U O Z Z U XrN 1 1.30 �LU W ILL. Z O \ Q J 14 rNJ \ Nr \ Q 1 � 1 Cz W c� W I..L k TIE TO EX. / W ` �( ' m rNJ .d \ 1 "V V] � LL `\ \ \ �Q PROJECT DETAILS Illt\\oPuc+��B'- tam+ �� �ntss v PROJECT MANAGER: AMH w l na DRAWN BY: RCM P'r lesra a 2 y 1 TO h�T ,y w';r t .. APPROVED BY: AMH II A plansan P. n "'S ar ,-.`Ka s r'the PROJECT NUMBER: 09007 �e°n-it $!t/GD�!(4�� !Z. l N SCALE "late: Qp21i VERT.: N/A III NS It ISSUE DATE 11 /24/2009 SHEET NUMBER Ili N U / C3 • 0 III w III � I \ cwi� VICINITY MAP(N.T.S.) GRADING / EROSION CONTROL NOTES 1 INSTALL GRAVEL CONSTRUCTION ENTRANCE (SEE SHT. C5.0, #5) 2 INSTALL TEMPORARY ACCESS BARRIER 3 INSTALL BLOCK & GRAVEL INLET PROTECTION (SEE SHT. C5.0, #10) 4 INSTALL TEMPORARY SEDIMENT FENCE (SEE SHT. C5.0, #7) 5 CONSTRUCT TEMPORARY DIVERSION BERM (SEE SHT. C5.0, #6) 6 CONSTRUCT TEMPORARY HARDWARE CLOTH & GRAVEL PROTECTION w/ BASIN (SEE SHT. C5.0, #11) 7 INSTALL DOUBLE NET STRAW EROSION CONTROL BLANKET ON ALL SLOPES 4:1 OR STEEPER (SEE SHT. C5.1, #10) B INSTALL TEMPORARY VELOCITY DISSIPATER / RIPRAP PROTECTION (SEE SHT. C5.0, #8 & 9) 9 CONSTRUCT TEMPORARY SEDIMENT TRAP w/ POROUS BAFFLES (SEE SHT. C5.1, #1 & 2) 10 INSTALL STORM DRAIN CLEAN OUT (SEE SHT. C5.1, #9) 11 INSTALL 18" x 18" JUNCTION BOX (SEE SHT. C5A, #8) 12 INSTALL STANDARD JUNCTION BOX (SEE SHT. C5.1, #6 & 7) 13 INSTALL CURB INLET (SEE SHT. C5.0, #3) 14 INSTALL DROP INLET (SEE SHT. C5.1, #4) 15 INSTALL 18" x 18" DROP INLET (SEE SHT. C5.1, N8) 16 INSTALL CONCRETE FLARED -END SECTION (SEE SHT. C5.1, #5) 17 INSTALL CONCRETE LEVEL SPREADER (SEE SHT. C5.3, #5) 1B CONSTRUCT WET POND PER DWQ REQUIREMENTS (SEE SHT. C5.7) ADDITIONAL NOTES 1. ALL GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND OTHER INFORMATION INDICATED ON THE TITLE PAGE SHALL APPLY TO THIS PLAN 2. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE VERIFIED BY THE GENERAL CONTRACTOR WITH THE SURVEYOR OF RECORD PRIOR TO BEGINNING CONSTRUCTION. BENCHMARK IS AN SET IRON PIPE BEING THE NORTH-EAST PROPERTY CORNER OF THE PROJECT SITE, AND HAVING AN NAVE) 88 ELEVATION OF 127.56 3. PURSUANT TO G.S.113A-57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR OTHER ADEQUATE EROSION CONTROL DEVICES OR STRUCTURES. IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN 21 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY OR PERMANENT GROUND COVER, DEVICES OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. PURSUANT TO G.S. 113A-57(3), PROVISIONS FOR PERMANENT GROUND COVER SUFFICIENT TO RESTRAIN EROSION MUST BE ACCOMPLISHED FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. ALL SEEDED AREAS WILL BE FERTILIZED, RE -SEEDED AS NECESSARY, AND MULCHED ACCORDING TO SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A VIGOROUS, DENSE VEGETATION COVER. IF ANY SEEDING FAILURE OCCURS, THOSE AREAS SHALL BE RE -SEEDED WITH RYE GRAIN FOR TEMPORARY STABILIZATION AND PREPARED FOR PERMANENT SEEDING. 4. SEE DETAIL SHEETS FOR EROSION CONTROL MEASURES & MAINTENANCE. 5. CONTACT PERSON: RANDALL STRICKLAND - STEDMAN PENTECOSTAL HOLINESS CHURCH - (910)-483-2611 6. PARCEL IDENTIFICATION NUMBER(S): 0495-07-0403, 0485-97-5327, 0465-97-4307 7. CONTRACTOR SHALL REMOVE TEMPORARY EROSION CONTROL MEASURES ONLY AFTER REMOVAL HAS BE APPROVED BY DENR. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING EROSION AND SEDIMENTATION CONTROL MONITORING ACCORDING TO NPDES PERMIT REQUIREMENTS. 9. SEE SHEET C5.0 FOR TEMPORARY & PERMANENT SEEDING REQUIREMENTS. 10. TOTAL DISTURBED AREA IS APPROXIMATELY 4.0 ACRES EROSION CONTROL CONSTRUCTION SEQUENCE 1. OBTAIN ALL NECESSARY PERMITS AND APPROVALS AND HOLD PRE -CONSTRUCTION CONFERENCE. 2. INSTALL GRAVEL CONSTRUCTION ENTRANCE. 3. INSTALL BLOCK AND GRAVEL INLET PROTECTION. 4. CONSTRUCT TEMPORARY DIVERSION BERMS, SILT FENCE AND HARDWARE CLOTH & GRAVEL OUTLET AS AREAS ARE BEING CLEARED AND GRUBBED. 5. CLEAR AND GRUB THE SITE WITHIN THE LIMITS OF CONSTRUCTION. 6. REMOVE AND RELOCATE EXISTING BUILDINGS ON SITE. 7. APPLY TEMPORARY SEEDING TO ALL DISTURBED AREAS AND APPLY EROSION CONTROL BLANKET TO ALL SLOPES STEEPER THAN 4:1 AS INDICATED ON THE PLANS. 8. ROUGH GRADE THE PROPOSED SLABS, PARKING, AND DRIVEWAYS. 9. INSTALL STORM WATER UTILITIES. STORM DRAINAGE SYSTEM WILL BE CONSTRUCTED SO THAT PERMANENT DRAINAGE OUTLETS RELEASE RUNOFF INTO THE STORM WATER DETENTION POND WHICH WILL ACT AS A TEMPORARY SEDIMENT TRAP. 10. INSTALL BLOCK AND GRAVEL INLET PROTECTION AT NEW STORM INLETS. 11. INSTALL TEMPORARY VELOCITY DISSIPATER(S) AS SHOWN IN THE PLANS. 12. INSTALL LEVEL SPREADER 13. INSTALL WATER AND SANITARY SEWER UTILITIES. 14. INSTALL CURB AND GUTTER AND CONCRETE SIDEWALKS. 15. INSTALL PAVEMENT IN PARKING AND DRIVEWAY AREAS. 16. CLEAN AND FLUSH STORM PIPES. 17. REMOVE TEMPORARY SEDIMENT TRAP UPON APPROVAL BY NCDENR 18. APPLY PERMANENT SEEDING TO ALL DISTURBED AREAS. 19. TEMPORARY MEASURES SHALL BE REMOVED AFTER APPROVAL FOR REMOVAL OF ALL TEMPORARY EROSION CONTROL MEASURES BY NCDENR HAS BEEN OBTAINED. TEMPORARY SEDIMENT TRAP NOTES 1. THE TEMPORARY SEDIMENT TRAP WILL BE CONVERTED TO A STORM WATER DETENTION POND. ALL SEDIMENT DEPOSITED DURING CONSTRUCTION MUST BE REMOVED, EROSION FEATURES MUST BE REPAIRED, AND THE VEGETATED SHELF MUST BE RESTORED, BEFORE OPERATION AS A STORM WATER BMP BEGINS. 2. A MINIMUM OF 6-INCHES OF BOTTOM MATERIAL (BELOW THE DESIGN BOTTOM OF THE ORIGINAL SEDIMENT & EROSION CONTROL DEVICE) MUST BE REMOVED PRIOR TO CONVERSION OF BMP BUILT UPON AREA CALCULATIONS ON SITE DRAINAGE AREA = 2.66 AC = 115,870 SF EXISTING IMPERVIOUS AREA = 0.17 AC = 7,405 SF PROPOSED IMPERVIOUS AREA = 1.49 AC = 64,904 SF TOTAL IMPERVIOUS AREA = 1.66 AC = 72,309 SF DENSITY FACTOR = 1.66 / 2.66 x 100 = 62% 20 GRAPHIC SCALE 10 20 (IN FEET) 1 inch = 20 It. 80 O \ w 1(iC\ \. w O\ O 0 4b deb 1 .5 \ \ \ 0.4 \ CI-8-j \ TOP=120.00 \ \ INV.-113.69 (24' IN) \ \ INV.-115.14 (12" IN) \ \ INV.=113.69 (24" OUT)\ \ 72U \ CI-7 X TOH-120.74 ''No INV.=113.79 (24' IN) \ 'eoINV.=113.79 (24" OUT) \ 139 LF 24" R 00.177 e•c+c 1i \ -UE J are instruments of service and shall remain the property of Crawford Design Company. The Owner or any other parties shall not use the work on this or any Droiect except by a 7 76 BSol \ \ \ \\ \ 41. 00 77,1 \ \ \ �\ �3 Kvvv Vvv vA\ V�7A d 7 \ O \\ j \ s \ \ \ 30' BUFFER PER ` \y \ \ \` \ d \ > \\ �� \ NNAMED STREAM � �\ DWO REQUIREMENTS Y \\ \ `\ \fix` \ \ \ \`\\ `\ \ \ \ \ \\ \ \ \ \ \ \NN \ \ \\\ \ NN \ 5 \ i\\\ \\ .\\\\ \ / I 'EX. BLDG. !J!!N \\/ o• \ TOP=11,178.75 I / / \ \\\\ \ INV.V113.34 (2424OUT) 1 / I\ OrC\\ \\ \ \ \ Wo / Co. • \ f Jl. \ \ \ \ N,� \ \ _ °N� \ \\ / \ / /' �+�•; �. .;:' \ \I\V.=9 2.00\0 (24 OUT) NX NOR�F �, /./ \ %` �: �;:,1 :� •,1\\ `fit\ `4 \\ \ NN \ 1 1 I II 1 I 1 \\ INV.=111.7 1 I I I \ \ \ 1 1 I \\� INV.=111.5 \ 1\ 1 11 \111 II SIPTBM ; I I \ .., SR/� SET IRON PIPE NELEV.=127.56 o A- R ST W\wo\\ � \ Aye lie ie W\\ -- / VEL DISSP. � \ �`•#' ' •���is\ \\\ / \ CLASS "B" STONE (6"0, LT) , !! R •; \ \ ! \ \ \V \ 151 x 8'W x 20'Wa NO. �i!!�� • o '�)�tt \ \ "; \ \ \\\\ \`\ / % \ \ \ � \ ,�{ , q 'Lro III 1 \\ / /. / I I •Stt ; g., •'; •,;;• • \ • \•. C.;• \ \ k \ I I �11 t I EX. PARSONAGE / I 1 : • ' ':+'`,; . ' i\''�L.G' \ ,�J lil\ II i \ / � I r�� �I � `;:. ,`' :• '���'r":'o'. (\ �\ `� 1 11I '711 1 I ` ' • ;: ,1 LO ATIbN O WET ' DETENTION POND JAI I II I POND WILL SERVE A , ; : \: , •; (SEE SHT. C5.7) / TEMP. 8' WEIR WILL I tl I .; , TOP ELEV.=117.50 BECOME PERMANENT I 1 I I TEMP. SED. TRAP / ONCE CONTR. INSTALLS \ I 1 ( ; '• 9 , '; . ; TOP TAREAV8,092 SF '% THE POND I I \ / \ TOP=117.50 :` ' I 1 807TOM=112.00 I I I OT. AR A=497 SF /22,ELEV.=116.50 \ // i II i 1\+`.,` `.% Ya / I WEIR LENGTH=8' II II • ` •)){; i, I I I 1 1 I fit III I I � ��� '•, , pp� ' `. '`•,''+,i .'�•:, fi 1 11 III I / I \ �: `y•,,`�,'' I 1 I III I I / � .<, • :�•:�^.'• .tf'; % �� 1nn2444� Po OUTLET STRTOP=R17.00 �31 / I 2 WEIRS O 1.0' EACH ` Cf 7 7!01 I I I I I WEIR ELEV.-116.50 :\ i 9 ORIFICE=4" 1 O 16 8 I I ORIFICE ELEV.-115.50 INV.=114.80 (18" OUT) -121- I so FES-1 INV.=114.60 (18" OUT) \\ I II III ; 8., PVPv W \ \ \ \ �\ 1 VEL DISSP.- I 1 I 1 CLASS "B" STONE (6"4, LT.) 1 O'L x 5'W x 15'W, I I �4 ` ` 4Vb s\ s \\ 4V& S\ \ S`SS a ' nc ents s 41/y `� --120-�\ \ \ \ \ \ I \ 11 onstru on o m t`, r n ur 4na ���5 \ v v I \ J 1 II Aj ru eU reqifed �re the e ',r r b �Sw A V v I A 1 I I t\ 1 I lana ing r of i� _r y nr mitt'©with ihf; s a� 51>.r ,n, \s \ \ I I \ / 1 I 11 1 r n annme \ \ \ \ K \ J tonnwa e •u U \ 1 s v v v v I / 1 1 1 1 I . erl n c�4 60ylA�l \ \1 M!b �S3. \SIZ-ta � �20 4V" 116 N. Cool Spring Street ♦ Fayetteville, NC 28301 Voice:910-221-0033 ♦ Fax:910-221-0035 www.crawforddsn.com O DESIGN D DESIGN 30S ooyq �o°o SEALS REVISIONS .i 1..6r. U Z) Q D V °' V..J w .� WQ V0 K V') f - ovO zz -i W Q O LnZ ov 0 W W Z z ` WZ� v0 CLQLU (/) LL Q�} p O ne 0 L'U J < W W �.. V)cnLL VdS PROJECT DETAILS PROJECT MANAGER: AMH DRAWN BY: RGM APPROVED BY: AMH PROJECT NUMBER: 09007 SCALE HORZ.: 1" = 20' VERT.: N/A ISSUE DATE 11 /24/2009 SHEET NUMBER C31 Crawfnrrl L)Pcian Cmmnanv Cc) Convriaht 2009 All drawings. soecifications and designs prepared by Crawford Design Company are instruments of service and shall remain the property of Crawford Design Company. The Owner or any other parties shall not use the work on this or any project except by a proper agreement and appropriate compensation. 411, \ \erg.-19- - - - - O 24" RCP (IN 1 \\ I \ \ INSTALL DBL. 6-FT \ BLACK -VINYL CHAIN LINK GATES \ s / \ FOREBAY \ J \ I, I - � I I / I FOREBAY i i INSTALL 4-FT HIGH BLACK -VINYL CHAIN LINK FENCE w�� \ \w \ \ UTLET STRUCTURE \ NSTALL4-FTHIGH BLACK -VINYL CHAIN LINK FENCE � RIP RAP \: pPROTECTION \`a �\ \ p \�V \�\< ` ASIN AREA 1 \ \ \ \ 3 1 \\ \ \\ EE NOTE #1 OF "ADD'L \ 1 \ 1 \\ \ \ NOTES & RQMTS" 1 1 1 \ 1 \ \ \ \ \ (TYP) -ft WIDE EMERGENCY \ \ ✓ / / SPILL -WAY FOR THE PERMANENT POND /" , I INLET i STRUCTURE \ `-LEVEL SPREADER 1 INSTALL DBL. l_ 18" RCP (OU I' I I� Ill 1 BLACK -VINYL CHAIN LINK GATES \ I ' I q� 111lI ; 11', \f 1 1 Il li BASIN PLAN VIEW (SCALE: 1" = 30') OPERATION AND MAINTENANCE AGREEMENT 13. IF EROSION IS OCCURRING IN THE SWALE, RE -GRADE THE SWALE IF NECESSARY AND PROVIDE EROSION CONTROL DEVICES SUCH AS REINFORCED TURF MATTING OR RIPRAP TO AVOID FUTURE PROBLEMS WITH 1. OWNER WILL KEEP A MAINTENANCE RECORD AT ALL TIMES. OWNER SHALL KEEP THIS RECORD IN A LOG AND KEEP THAT LOG IN A KNOWN SET LOCATION TO BE AVAILABLE AT ALL TIMES. 14. EROSION. IF SEDIMENT ACCUMULATES IN THE FOREBAY TO A DEPTH GREATER THAN THE ORIGINAL DESIGN DEPTH FOR 2. ANY DEFICIENT BMP ELEMENTS NOTED DURING THE INSPECTION WILL BE CORRECTED, REPAIRED OR SEDIMENT STORAGE, SEARCH FOR THE SOURCE OF SEDIMENT AND REMEDY THE PROBLEM IF POSSIBLE. REPLACED IMMEDIATELY. REMOVE THE SEDIMENT AND DISPOSE OF IT IN A LOCATION WHERE IT WILL NOT CAUSE IMPACTS TO STREAMS 3. IMMEDIATELY AFTER THE WET DETENTION BASIN IS ESTABLISHED, THE PLANTS ON THE VEGETATED S 1ELF AND OR THE BMP. PERIMETER OF THE BASIN SHOULD BE WATERED TWICE WEEKLY IF NEEDED, UNTIL THE PLANTS BECOME 15. IF EROSION HAS OCCURRED IN THE FOREBAY, PROVIDE ADDITIONAL EROSION PROTECTION SUCH AS ESTABLISHED (COMMONLY SIX WEEKS). REINFORCED TURF MATTING OR RIPRAP IF NEEDED TO PREVENT FUTURE EROSION PROBLEMS. 4. NO PORTION OF THE WET DETENTION POND SHOULD BE FERTILIZED AFTER THE FIRST INITIAL FERTILIZATION 16. IF WEEDS ARE PRESENT IN THE FOREBAY, REMOVE THEM PREFERABLY BY HAND, BUT IF PESTICIDES ARE USED, THAT IS REQUIRED TO ESTABLISH THE PLANTS ON THE VEGETATED SHELF. STABLE GROUNDCOVER SHOULD BE MAINTAINED IN THE DRAINAGE AREA TO REDUCE THE SEDIMENT LOAD TO 17. WIPE IT ON THE PLANTS RATHER THAN SPRAYING. WHEN BEST PROFESSIONAL PRACTICES SHOW THAT PRUNING IS NEEDED TO MAINTAIN OPTIMAL PLANT HEALTH 5. THE WET DETENTION BASIN. IN THE VEGETATED SHELF, PRUNE ACCORDING TO BEST PROFESSIONAL PRACTICES. 6. IF THE BASIN MUST BE DRAINED FOR AN EMERGENCY OR TO PERFORM MAINTENANCE, THE FLUSHING OF 18. IF THERE ARE DEAD, DISEASED OR DYING PLANTS IN THE VEGETATED SHELF, DETERMINE THE SOURCE OF THE SEDIMENT THROUGH THE EMERGENCY DRAIN SHOULD BE MINIMIZED TO THE MAXIMUM EXTENT PRACTICAL. PROBLEM: SOILS, HYDROLOGY, DISEASE, ETC. REMEDY THE PROBLEM AND REPLACE PLANTS. PROVIDE A 7. ONCE A YEAR, A DAM SAFETY EXPERT SHOULD INSPECT THE EMBANKMENT. ONE-TIME FERTILIZER APPLICATION TO ESTABLISH THE GROUND COVER IF A SOIL TEST INDICATES THAT THIS IS 8. AFTER THE WET DETENTION POND IS ESTABLISHED, IT SHOULD BE INSPECTED ONCE A MONTH AND WITHIN 24 NECESSARY. HOURS AFTER EVERY STORM EVENT GREATER THAN 1.0 INCHES (OR 1.5 INCHES IF IN A COASTAL COUNTY). 19. IF WEEDS ARE PRESENT IN THE VEGETATED SHELF, REMOVE THEM BY HAND PREFERABLY, OR IF PESTICIDES RECORDS OF OPERATION AND MAINTENANCE SHOULD BE KEPT IN A KNOWN SET LOCATION AND MUST BE ARE USED, WIPE ON THE PLANTS RATHER THAN SPRAYING. AVAILABLE UPON REQUEST. 20. IF SEDIMENT HAS ACCUMULATED TO A DEPTH GREATER THAN THE ORIGINAL DESIGN SEDIMENT STORAGE 9. IF THERE ARE AREAS OF BARE SOIL AND/OR EROSIVE GULLIES AROUND THE PERIMETER OF THE WET DEPTH IN THE MAIN TREATMENT AREA, SEARCH FOR THE SOURCE OF THE SEDIMENT AND REMEDY THE DETENTION BASIS, RE -GRADE THE SOIL IF NECESSARY TO REMOVE THE GULLY, AND THEN PLANT A GROUND PROBLEM IF POSSIBLE. REMOVE THE SEDIMENT AND DISPOSE OF IT IN A LOCATION WHERE IT WILL NOT CAUSE COVER AND WATER UNTIL IT IS ESTABLISHED. PROVIDE LIME AND ONE-TIME FERTILIZER APPLICATION. IMPACTS TO STREAMS OR THE BMP. 10. IF THE VEGETATION IS TOO SHORT OR TOO LONG AROUND THE PERIMETER, TAKE STEPS TO MAINTAIN 21. IF ALGAL GROWTH IN THE MAIN TREATMENT AREA COVERS 50% OF THE AREA, CONSULT A PROFESSIONAL TO 11. VEGETATION AT A HEIGHT OF APPROXIMATELY SIX INCHES. IF PIPE FOR THE INLET IS CLOGGED, UNCLOG THE PIPE. DISPOSE OF THE SEDIMENT OFFSITE. 22. REMOVE AND CONTROL THE ALGAL GROWTH. IF CATTAILS, PHRAGMITES OR OTHER INVASIVE PLANTS IN THE MAIN TREATMENT AREA COVER 50% OF THE 12. IF THE PIPE IS CRACKED OR DAMAGED, REPLACE THE PIPE. BASIN SURFACE, REMOVE THE PLANTS BY WIPING THEM WITH PESTICIDES, (DO NOT SPRAY). ADDITIONAL NOTES & REQUIREMENTS 1. AREA AROUND POND SHALL BE ESTABLISHED WITH PERMANENT GROUND COVER PER SPECIFICATIONS AND VOID OF ANY BARE AREAS. r,C T/ L,AT, ID A, no A C L1.1 nD �% 1 UCI EINI AS NOTED 4 4" 0 ORIFICE ELEV.=117.00 PVC TEE FITTING -� 4" 0 ORIFICE PLAN VIEW GRATE WEIR WIDTH=1.0-FT (2 SIDES) FEEL GRATE WEIR WIDTH=1.0-FT (2 SIDES) CORROSION RESISTANT SLUICE GATE PER MANUF. RECOMD. (WATER MAN SERIES 3000 OR APPROVED EQUAL) 1 ANTI-FLOATION CROSS SECTION VIEW STRUCTURE DETAIL ( N . T . S . ) (SEE EROSION CONTROL PLAN) ( N . T . S . ) (TYP) (SEE UtIAIL) \ ki 1 VEGETATIVE SHELF LANDSCAPE PLAN (SCALE: 1" = 30') Vegetative Shelf Landscape Planting Table Key Common Name Botanical Name Quantity Type Description JE Sottrush Juncus eflusus 1.56 1 yuari - IV Blue Flag Iris Iris versicolor 55 1 quart - PC Pickerelweed Pontederia cordate 49 1 quart PV Arrow Arum Peltandre vir inica 21 1 quart - SC Lizard Tail Saururus cemuus 37 1 quart TIE 10 NATURAL GRADE (4:1 OR >) (COMPACT TO 98% PROCTOR) 116 N. Cool Spring Street ♦ Fayetteville, NC 28301 Voice:910-221-0033 ♦ Fax:910-221-0035 www.crawforddsn.com u p DES I[;N O pES 10 1 3,ro �„ goy4 oQ' , 4�gco 0 3 CERT. No. , - t. ? CERT. No 5 < t C-136 _ C-2097 g •1 ?P ' • .r. M1ogr" cA"o` � G q �rN CAPO`"` G. e,ILLE• N y EV ILLE• `, .n SEALS ,ac,l, zr�c5tu�r3eaa&er r>•-.,.-. ansens� :;u v ru r�eru � 1arna r 1 ,un ants ir, SO- ;P.gwred i.y trs 11•1.va.rr ra _; th `aroiina ,ules requi a t1 r nnl : " stun aeslgl er Inshe4t daleg , ,, . _.r. (•xr T v wl;h {hi, plans an. seal m < fc stianoe- ::, the stofrnwa (' -,005lDi ?en tt' .54/609(00,( `-ai�12�7�Zoa�/ oY2f7 0 �if/W.."i - 5n Cr '..re' G1131i1,; 3 ` 111, T21 102� m. REVISIONS U � ~ 2 O �U r �- U J N W J ZV Q oO Z �W O Z U LU w 7 L �°'z O CL < LU ~ Q J LU F- LUcn LU c� rn) LL. PROJECT DETAILS PROJECT MANAGER: DRAWN BY: APPROVED BY: PROJECT NUMBER: AMH RGM AMH 09007 SCALE AS NOTED ISSUE DATE 11 /24/2009 SHEET NUMBER C5. 7