Loading...
HomeMy WebLinkAboutNCG030039_Monitoring Report_20220628DAIMLER Colin Buchanan Sr. Environmental Engineer Daimler Trucks 11550 Statesville Blvd Cleveland, NC 27013 704.645.5353 Phone June 241h, 2022 Division of Water Quality Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, NC 28115 To whom it may concern: Please find enclosed May's stormwater sampling results for Stormwater Discharge Outfall #002. There was no qualifying event for the month of May. Daimler's Cleveland facility has exited tier three at SDO #001 and is monitored on a quarterly basis. Should you have any questions, please contact me at 704-645-5353 or colin.buchanan@daimler.com. Sincerely, Daimler Trucks, LLC Colin Buchanan Sr. Environmental Engineer SHIELD ENGINEERING June 3, 2022 Mr. Colin Buchanan Daimler Trucks of North America, LLC 11550 Statesville Boulevard Cleveland, NC 27013 rns�a F„v v �o h o� Subject: Stormwater Sampling — May 2022 NPDES General Permit No. NCG030000/CoC No. NCG030039 Daimler Trucks of North America, LLC 11550 Statesville Boulevard, Cleveland, North Carolina Shield Project No. 1140111-10 Dear Mr. Buchanan: There were no qualifying rainfall events for the month of May 2022 as defined by General Permit No. NCG030000. As a result, no monthly stormwater samples were collected for Stormwater Discharge Outfall (SDO) #002 at the Daimler Trucks — Cleveland Facility in May. According to rainfall data' collected for the month, three rain events or group events occurred on May 61h May 12th and May 215t, producing 0.67 inches, 0.22 inches and 3.35 inches of rain, respectively. However, each of these events took place after normal business hours, within 72 hours of the last rain event, or did not produce enough rainfall to collect a sample. Shield will continue to monitor daily weather conditions and attempt coordination of appropriate staff and resources to facilitate adequate sample collection. A partially completed Discharge Monitoring Report form is attached to this cover letter for signature of the appropriate authorized permittee and submittal to the State. Daimler's Cleveland facility has exited Tier Three at SDO #001 for Copper and is monitored on a quarterly basis. The facility remains in Tier Three of the NPDES General Permit No. NCG030000 at SDO #002 for Copper and Zinc. Shield greatly appreciates the opportunity to provide environmental services to Daimler Trucks of North America. If you have any questions in reference to this document or require further information, please feel free to contact undersigned at (704) 394-6913. Respectfully, SHI D ENGINEERING, INC. Magdaline =nnis�� 4 Senior Project Manager ebbertL. Griffin, P.E. President/CEO Attachment: Discharge Monitoring Report — May 2022 ' Rainfall data collected from onsite rain gauge by DTNA-Cleveland. 4301 Taggart Creek Road www.shieldengineering.com Telephone 704.394.6913 Charlotte, NC 28208 License No. F-0856 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0039 Person Collecting Samples: NA Facility Name: Daimler Trucks- Cleveland, NC Laboratory Name: NA Facility County: Rowan Laboratory Cert. No.: NA Discharge during this period: Yes No (if no, skip to signature and date) Has yourfacility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Yes No If so, which Tier (l, ll, or III)? A copy of this DMR has been uploaded electronically via https:/Iedocs.deg.nc.goy/Forms/SW-DMR Yes EjNo Date Uploaded: (c 24 Z,i,2 Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall 001 Outfall002 Outfall Outfall Outfall Code N/A Receiving Stream Class C C N/A Date Sample Collected MM/DD/YYYY NQE 46529 24-Hour Rainfall in inches C0530 TSS in mg/L (100 or 50*) pH in standard units (6.0-9.0 FW, 00400 6.8-8.5 SW) Copper, total recoverable in mg/L 01119 (0.030 FW, 0.0058 SW) Lead, total recoverable in mg/L 01051 (0.075 FW, 0.22 SW) Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) Chemical Oxygen Demand (COD) in 00340 mg/L(120) 00552 Non -Polar Oil & Grease in mg/L (15) * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): NQE during this period (May 2022) for SDO #002. SDO #001 is on a quarterly schedule. "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, tot e best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false infor, , 1 including tl ssibility of fines and imprisonment for knowing violations." Signature of Address or Delegated Authorized Individual Date Phone Number