Loading...
HomeMy WebLinkAboutSW3220305_Plansheet C-000-001 - Notes_202206151 2 3 0 5 0 n C C� J B w z Q m o 0 L W U cQ U � Q W Q U L0 0 L0 N N O N c0 M lii Q 0 O J d c� 0 0 0 0 0 0 U rn 00 (0 It LO A 11J 2 Q z w J U_ N i U m_ U UTILITY LINE DESIGNATIONS SITE AND SURVEY CONTROL SYMBOLS SOIL BORINGS GENERAL NOTES Brown AND EXISTING 1. GEOTECHNICAL INFORMATION USED IN THE PREPARATION OF DRAWINGS AND SPECIFICATIONS IS 1. DRAWING NUMBERING LEGEND FOR CIVIL DRAWINGS IS BELOW. FOR SERIES WITH AN 'X,' SEE THE Caldwell BASED UPON TWO DIFFERENT EXPLORATIONS AND TESTS OF SUBSURFACE CONDITIONS AT THE SITE BY RESPECTIVE OVERALL KEYPLAN SHEET FOR LEGEND. PIPE LESS THAN 12" IN DIAMETER RIGHT-OF-WAY S&ME. C-000-10X - EXISTING SITE CONDITIONS CD-000-1 OX - SITE DEMOLITION ENVIRONMENTAL ENGINEERING AND CONSULTING PIPE 12" IN DIAMETER OR LARGER PROPERTY LINE 2. THE FIRST EXPLORATIONS ARE INCLUDED IN A REPORT DATED OCTOBER 14, 2020 ENTITLED C-000-20X - PAVING AND STRUCTURES 309 East Morehead Street, Suite 160, Charlotte, NC 28202 "GEOTECHNICAL ENGINEERING REPORT, ROCKY RIVER REGIONAL WWTP EQ TANKS, REVISION NO. 1." C-000-30X - GRADING AND DRAINAGE (704) 358-7204 North Carolina Board of Examiners for Engineers and FIBER OPTIC - - - - - - - - - - - - - - - - PRIVATE EASEMENT LINE THESE BORES ARE DELINEATED ON THE PLANS AS "® BORE A-XX." C-000-40X - YARD PIPING Surveyors License No. F-0785 C-000-50X - YARD PIPING PROFILES FORCE MAIN WOODS (TREE) LINE 3. THE SECOND EXPLORATIONS ARE INCLUDED IN A REPORT DATED SEPTEMBER 9, 2021 ENTITLED C-000-60X - EROSION & SEDIMENTATION CONTROL "GEOTECHNICAL ENGINEERING REPORT, ROCKY RIVER REGIONAL WASTEWATER TREATMENT PLANT C-000-61X - EROSION & SEDIMENTATION CONTROL NOTES AND DETAILS GAS - - STREAM CHANNEL (RRRWWTP)." THESE BORES ARE DELINEATED ON THE PLANS AS'BORE B-XX." C-000-80X - STANDARD DETAILS c C ss ss ss- SANITARY SEWER EDGE OF ROADWAY / DRIVE 4. THE REPORTS CONTAIN TECHNICAL DATA UPON WHICH THE DESIGN -BUILDER MAY RELY. BORE 2. THE CONTOUR INTERVAL ON ALL SHEETS IS ONE FOOT. LOCATIONS SHOWN ON THE PLANS ARE GENERAL IN NATURE. ACTUAL LOCATIONS, IF NEEDED, SHOULD T T T - TELEPHONE FENCE (WIRE) BE COORDINATED WITH S&ME. 3. DESIGN -BUILDER SHALL RECONSTRUCT ALL LAND DISTURBED BY CONSTRUCTION ACTIVITIES TO ITS ORIGINAL GRADE AND LOCATION UNLESS NOTED OTHERWISE. �� ••` '�H CARQ , ,�'' FH FH FEMA 100-YR FLOODPLAIN ``��0�•••ESS/ ••�/� Tv Tv Tv- TELEVISION :� C�•• OF O,y•.;9 4. EXISTING PIPING IS DESIGNATED BY SERVICE WITHOUT IMPLICATION AS TO PIPING MATERIAL. EXISTING q - ue ue ue UNDERGROUND ELECTRIC » » DITCH CENTERLINE PIPING MATERIAL, IF KNOWN, IS INDICATED SEPARATELY, AND MAY NOT BE THE SAME MATERIAL AS SEAL Z w w w WATER SPECIFIED FOR NEW PIPING FOR THE SAME SERVICE. • • ;;65 k`: '^ 5. SEE PIPING SPECIFICATIONS (PIPE SPECS) FOR PIPING SYSTEM REQUIREMENTS. t 6. THE UNDERGROUND UTILITIES HAVE NOT BEEN PHYSICALLY LOCATED. THE UNDERGROUND UTILITIES 0� •��,,DE14% SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE UNDERGROUND UTILITIES LOCATION, SIZE, AND ELEVATION ARE APPROXIMATE, AND ARE INTENDED TO 03/22/22 4:06 PM INDICATE THE EXISTENCE OF SUCH UTILITIES IN THE AREAS SHOWN. BEFORE PROCEEDING WITH THE PROPOSED WORK, THE DESIGN -BUILDER SHALL VERIFY UTILITY LOCATIONS AND NOTIFY THE DESIGN -ENGINEER IN 0 BENCH MARK WRITING OF ANY DISCREPANCIES. PIPE LESS THAN 12" IN DIAMETER • BOLLARD PROJECT INFORMATION 7. CONTINUITY OF SERVICE FOR ALL UTILITIES SHALL BE MAINTAINED DURING CONSTRUCTION. PIPE 12" IN DIAMETER OR LARGER O CLEANOUT 8. UTILITIES DAMAGED DURING CONSTRUCTION SHALL BE REPLACED AT NO COST TO THE OWNER. ® CURB INLET 1. SEE DRAWING C-000-611 FOR ADDITIONAL PROJECT INFORMATION AND EROSION AND SEDIMENTATION CONTROL NARRATIVE. ® DROP INLET 2, E TOT DIST ED A FOR E PR CT IS 88 AC S. ELECTRICAL MANHOLE 3. A WATERS OF THE U.S. ASSESSMENT REPORT WAS COMPLETED FOR THE RRRWWTP AND NO FINAL DRAWINGS - FOR REVIEW 0 ELECTRICAL BOX JURISDICTIONAL WATERS OF THE U.S. OR NON -JURISDICTIONAL WETLANDS WERE IDENTIFIED WITHIN PURPOSES ONLY - NOT THE PROPERTY BOUNDARY. THE FINDINGS OF THE ASSESSMENT ARE DETAILED IN A REPORT COMPILED RELEASED FOR CONSTRUCTION BY S&ME DATED JULY 20, 2021. ❑ ELECTRICAL PEDESTAL 4. ALL PROJECT WORK IS LOCATED WITHIN THE RRRWWTP PARCEL BOUNDARY DESCRIBED BY DEED BOOK FIRE HYDRANT 1 51 PAGE 213. CA ARRUS COUNTY PARCEL NUMBER IS 5547 6454800 0. FLARED END SECTION 5. FLOOD AREAS WITHIN THE SITE ARE IDENTIFIED FROM FEMA FLOOD INSURANCE RATE MAP, NORTH WSACC o FLAG POLE CAROLINA, PANEL 3710554700K, REVISED NOVEMBER 16, 2018. ❑ JUNCTION BOX 6. EXISTING CONDITIONS AND TOPOGRAPHIC INFORMATION WAS COMPILED FROM A PHOTOGRAMMETRIC EROSION &SEDIMENTATION CONTROL SURVEY COMPLETED BY AVIOIMAGE DATED JULY 27, 2021. DESIGNATIONS � LAMP POST 7. ELEVATIONS SHOWN REFER TO LOCAL PLANT DATUM. LYSIMETER 7.1. THE PLANT DATUM IS 0.64 FEET HIGHER THAN THE NATIONAL GEODETIC VERTICAL DATUM, 1929 (NGVD 29) O MANHOLE 7.2. THE PLANT DATUM IS 1.46 FEET HIGHER THAN THE NORTH AMERICAN VERTICAL DATUM, 1988 (NAND 88). ROCKY RIVER LOD LOD LIMITS OF DISTURBANCE (LOD) � PIEZOMETER 8. COORDINATES SHOWN REFER TO LOCAL PLANT DATUM. THE DATA IS SCALED FROM NCGS MONUMENT REGIONAL SILT FENCE "WSAAC" USING A COMBINED GRID FACTOR OF 0.99985065 AND A NORTHING SHIFT OF +1.620' AND A • FASTING SHIFT OF-0.8000'. WASTEWATER TD ­4 TD ,W TD - DIVERSION DITCH SHRUB/TREE 8.1. THE GRID COORDINATES NAD83(2011) OF NCGS WSACC ARE: 8.1.1. NORTH = 578,045.171 TREATMENT PLANT ® SOIL BORING LOCATION 8.1.2. EAST = 1,540,108.711 "WSACC" PHASE 3 EXPANSION 8.2. THE PLANT COORDINATES OF NCGS ARE: ® x VALVE 8.2.1. NORTH = 578,046.791 8.2.2. EAST = 1,540,107.911 REVISIONS SILT FILTER BAG YARD HYDRANT REV DATE DESCRIPTION SILT FENCE OUTLET o o PROPOSED GRAVEL ROAD G� WATTLE PROPOSED ASPHALT ROAD 0DROP INLET PROTECTION F■ CATCH BASIN INLET PROTECTION e PROPOSED CONCRETE SIDEWALK °�O ROCK INLET PROTECTION UTILITY TO BE DEMOLISHED LINE IS 2 INCHES 0 AT FULL SIZE ROAD TO BE DEMOLISHED DESIGNED: D. WRIGHT SOIL STOCKPILE DRAWN: R. JAMES ----------------------- PAVEMENT TO BE DEMOLISHED FOR CHECKED: K. DEVENDORF 7 DAY SOIL STABILIZATION AREA =______________________ UTILITY INSTALLATION CHECKED: D. VARJABEDIAN APPROVED: K. DEVENDORF FILENAME 154689-C-000-001. DWG BC PROJECT NUMBER 156673 CLIENT PROJECT NUMBER CIVIL SYMBOLS, ABBREVIATIONS AND NOTES DRAWING NUMBER C-000-001 Xx SHEET NUMBER ____ OF C C I 1 VA 3 m 5 on