Loading...
HomeMy WebLinkAboutSW3220301_Plansheet 8 - Misc. Detail_20220420First Chamber Second Chamber 259eb of surface area 250,6 of surface area Outlet zone of surface area Inlet zone 25% of surface area S'Crest ffidth 14 I nflow Structure " mI, Skimmer Dewatering Device Riprap or Slope Drain Earthen embankment ' Emergency N" voith stabilized s,� Spillway side slopes Baffles Figure 6.65a Porous baffles in a sediment basin. The flow is distributed eventy across the basin to reduce flow rates and turbulence, resulting in greater sediment retention. Extend 9 gaugewireto basin side or instalIT-post to anchor Drape baffle material over wire strand and secure with plastic ties at posts and onwire every 12* baffle to side of basin ands wire to vertical post 4'Max. --P� I I 9GaugeMinHiqh ------ o0` T Tension Wte Strand 3WK* shall Be Secured To Post To Support &Affle filaterial - R-W 012110EM If the temporary sediment basin will be converted to a permanent stormwater basin of greater depth, the baffle height should be based on the pool depth during use as a I temporary sediment basin. Ir V6 'glam1 mg Baffle hiaterial 11 Gauge Landscaping Staple I_- J 'K i� Steel Post 2'-O'Depth 11-ri Baffle hiaterial should be secured to the bottom and sides of basin using 12'fan dscape staples WATER ENTRY UNIT GENERAL NOTES: WITHTRASH SCREEN I' PROPER DESIGN MUST BE COMPLETED TO MINIMIZE PIPING AROUND DISCHARGE PIPE. 21 PROPER ORIF CE OPENING MUST BE SELECTED TO ENSURE POND DRAINS IN CORRECT AMOUNT OFTIME. MODIFICATIONS MAYBE REQUIRED IF FIELD CONDITIONS WARRANT A CHANGE 3. EMBANKMENT MUST BECOMPACTED TO DESIGN SPECIFICATIONS, r 4. EMERGENCY SPILLWAY MUST BE CORRECTLY SIZED AND EROSION PROTECTION INSTALLED. 5. EROSION PROTECTION MUST BE INSTALLED ALONG THE EMBANKMENT AND AT THE ORIFICE OPENING INSIDE THE ORIFICE DISCHARGE END OF THE PIPE ONTAL TUBE WITH A S. INSPECT SYSTEM REGULARLY TO ENSURE IT IS FUNCTIONING IN A CORRECT MANNER. CONSTANT HYDRAULIC HEAD 7. EIGHT SIZES OF SKIMMERS ARE AVAILABLE, REFER TO THE FLOW SHEET, CUT SHEET, AND INSTRUCTIONS ON WEB SITE FOR EACH SIZE, SCHEDULE 40 PVC, PIPE (BARREL OR ARM) FLEXIBLE HOSE NO POTENTIAL FOR PIPING CAN OCCUR. PROPER DESIGN TO MINIMIZE DISCHARGE AROUND PIPE MUST OCCUR. WATER ENTRY UNIT THEN EMBANKMENT EMERGENCY SPILLWAY SCHEDULE 40 PVC (BARREL OR FLEYJBLEHOSE ---i PVC V, It i40ffin a&-a-M a 0 MIN M 1 %1101 11Y.". M. END VIEW SIDE MEW MAINTAIN DEPRESSION TO DISCHARGE PIPE MINIMIZE CHANCE OF SKIMMER SCHEDULE40 (NO SCALE) BECOMING STUCK DRAWN BY T. R. EVANS I(VID J.W.FAIRCLOTH&SON WC. WWW.FAjRCL0niSyjMMMC0M FAIRCLOTH SKIMMER DISCHARGE SYSTEM WITH EMBANKMENT TELEPHONE: (919) 73ZI244 FAX: (919) 732-1266 EMAIL: WARRENDFAIRCLOTHSKJMMEP-COM (Ref. Full Detail Sht-5) 4" CONCRETE 1-011 COVER iv x "n SKIMMER OPENING 3 SIDES) 559.30 3" Threaded PVC* . . . . . . . . . . . . . . . and hamberto be constructe C9 during conversion to final SCM 15"HDPE PIPE 555.5 Basin Bottom( 555.5 . g < *3" ThreadedV to be to be 6" PVC Coupling and cap for sand caAped as Emergency Drain for filter's 6" PVC underdrain be -in final SCM. EROSION CONTROL PHASE MODIFICATION OF iSCM CONCRETE OUTLET STRUCTURE (NTS) I RA5, it 1iP%CK­­, 1-4 lZ _7 x RMUR E L 4 PIPE j + 1 V 8 Y/ 141111 , 0 IM] 0 N 3 LOCK SECTIONAL VIEW cut -oil, StisBULED I It 1:114 01 COL VUR OUILH 2"DELP REFERENCE SHEET 5 FOR CUT-OFF TRENCH SIZING WITHI NOTES rMMMOMI'Mr-11 0%..-IVI L11V11 I 1. SEED AND PU%CE MATTING FOR EROSION CONTROL ON INTERIOR AND EXTERIOR SIDESLOPES. 2. INST-%LL A MINIMUM OF 3 COIR FIBER BAFFLES IN ACCORDANCE WITH PRACTICE STANDARD 6,65. 3. INSTALL SKIM IVER AND COUPLING TO RISER STRUCTURE OR DIRECTLY INTO EMBANKMENT I FT. FROM BOTTOM, OF BASIN. 4. THE ARM, PIPESH41.1. 144VEA N',IN IMUM LENGTH OF G FT, BETWEEN THE SKIMMERAND COUPLING. E 2.5" Faircloth SkimmerO Surface Drain Cut Sheet J. W. Faircloth & Son, Inc. www.FairclothSkimmer.com RIN11"ISTIT-1741IT07. M, 4" Sch 40 coupling connection IF 1 1/2" Vent with Green tip 2 1/2" pvc float 1 1/2" Sch 40 SOLID pvc; barrel or "arm" SUPPLIED BY USER 3 I. RGERSIRLICTURE SKI M-ME It (SVE lb'i It, I STEM POS IS [QUAN II I YMUL) UNA 1101, N K N04 E N 1 ST 01IE RGY PLASI K' SLOPE MW N N PE 4 L k No DISSiPMOR (Plt;ac I ICESIANDPARD 6321 GWIEXULELINING IEMPORARYOR PERMPNO41 MICH Q0 L Y S P I L 014%Y MERG E (PRPC'IlCE STANDARD 6.651 SIC* CPAO­j PLAN VIEW 6 M7 7A L P C 57 -ERENCE SHEET 5 PERMANENT RISER RUCTURE DETAIL 10P 01. EM8AJ1JK%01EN1­-­,N \ 111=111IMiiii IN ww CiAss 115 101114111 ON suspending horizontal intake 5 29,,2 29,,2 IVA Patent#: 5,820,751 Orifice PLATE for inlet A hose, ss clamps 2 1/2" inlet 2.5" HEAD [distance 2" threaded male fitting extension 4 from center of on outlet end orificefirilet to water surface 1. Skimmer can be attached to a straight 4" sch 40 pipe through the dam but the pipe may need 'to be anchored to the bottom at the connection so it is secure. Coupling can be removed and hose attached t .outlet using the threaded 2" fitting. Typical methods used: a) a metal structure with a steel stub out welded on the side at the bottom with a 2" threaded coupling or reducer(s); b) a concrete structure with hole or orifice at the bottom - use a steel plate with a hole cutin it and coupling welded to it that will fit ,over the hole in the concrete and bolted to the structure with sealant; or c) grout a 4" pvc pipe in a hole i the concrete toonnect the skimmer. 2. Dimensions are approximate, not intended as plans for construction. 3. Barrel (solid, not foam core pipe) should be 1.4 times the depth of water with a minimum length of 6' so the inlet can be pulled to the side for maintenance. If more than 8' long weight may have to be added to inlet to counter the increased buoyancy. Orifice/inlet tapers down from 2 1/2" maximum inlet to a 11/2" barrel and hose., Barrel is smaller to redu buoyancy and tendency to lift inlet but is sufficient for flow through inlet because of slope. The orifice/inl can be reduced using the plate and cutter provided to control the Outflow rate - see #6. 5. Horizontal intake is 5" pipe between the straps with aluminum screen door for access to the 2Y2" inle and orifice inside. :6. Capacity: 6 234 cubic feet per day maximum with 21/2" inlet and 2.5 head. Inlet can be reduced by installing a smaller orifice using the plate and cutter provided to adjust flow rate for the particular ,drawdown time required. Please use the sizing template at wwwfairclothskimmer.com . 7. Ships assembled. User glues inlet extension and barrel, installs vent, cuts)orifice in plate and attach Ito outlet pipe or structure. Includes float, flexible hose, rope, and orifice plate and cutter. Does NOT include 1 1/2" Sch 40 SOLID pvc barrel or "arm" � SUPPLIED BY USER. 2-5inchCut 5-1-19 (0 J. W. Faircloth & Son, Inc. 20 BOTTOM RISER CREST EMER. SPILL. TOP OF DAM DE'TTWTERIi11G1 ELEVATION ELEVATIO TION I- N' ELEVA rTIME *Opening Elevation of SCM Riser TEMPORARY SKIMMER SEDIMENT BAS111 ------- -------- ­ ------ F Permanent Liner: Tall Fescue C: (See Seeding Spec's) Temp. Liner Width 4.50' 0 1,0 0. Temporary Liner: STRAW WITH NET 5 (NAG S75 or equal, Staple Pat. A) PER I MANENT IT Trapezoidal T------------ d b e x-section area(A)= bd + Zd 2 z d top width (T) = b + 2dz CHANNEL DATA BLOCK CHANNEL Avg TEMPORARY DESIGNATION b d T z LINER MTL. Permanent Ditch-PD1 (1.4%) 0.5' 1.0' 4.5' 2.0 STRAW Will. NET Permanent Ditch-PD2 (2.57.) ---T -6.-5,71 _o'_T_4._5,T_2.o STRAW WITH NET "STRAW WITH NE-r' TO BE NAG S75, OR EQUAL CROSS SECTION GEOMETRY OF GRASS -LINED DIVERSION CHANNELS NTS ILL SLOPE 12MIL PLASTIC SHEETING SHEETING 2'MIN Z IN ST WIDTH FlIVISF, ------- COMPACTED IVATUFU DIVERSION BERM (0 ANCHOR 6" MIN WIDTH AND DEPTH TO BE DESIGNED BY ENGINEER (11' MIN) ANCHOR 6" MIN NJ .I� i,!��iI�I��N ail � IIII�III��,�,I,��!�I I. ri ........... /Af C211 7 nip Kevin E. Herring ENGINEERING 16101 SllverRoad Oakboip, NC28129 ail -621-0935 DATE. 12/15/2021 HORIZ. SCALE NIA VERT. SCALE NIA DRAWN BY. keh o