Loading...
HomeMy WebLinkAboutSW8070727_Historical File_20121025AN 1.9 WA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Wakild, P. E. Dee Freeman Governor Director Secretary October 25, 2012 Bobby Hall, Executive Vice President State Employees' Credit Union P.O. Box 27685 Raleigh, NC 27611 Subject: State Stormwater Management Permit No. SW8 070727 MOD SECU Myrtle Grove Modification High Density Commercial Infiltration Basin Project — Alternative Design New Hanover County Dear Mr. Hall: The Wilmington Regional Office received a complete modified Stormwater Management Permit Application for State Employees Credit Union — Myrtle Grove Office on October 1, 2012. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000 and post construction requirements under SL 2006-246. We are forwarding Permit No. SW8 070727 MOD dated October 25, 2012, for the construction, operation, and maintenance of the subject project. The modifications covered by this permit include: 1. The conversion of an existing wet detention pond to an infiltration basin. The infiltration basin has been overdesigned per BMP manual Chapter 16.3.9, option 3 in accordance with the alternative design criteria per Section .1008 (h) of the stormwater rules. 2. The overall site layout and grading are not changing. 3. Plan sets have been combined. Since overall site layout is not changing, we have combined the new plan set with the old plans per the following instructions: a. Remove Sheet L0101 Overall Tract Existing Conditions / Demo / EC Plan b. Remove Sheet C5101 Utility Details c. Remove Sheet C5102 Stormwater Pond Details d. Keep Sheet C1201 Grading, Drainage. EC & Stormwater Plan. Cross out wet detention pond and note that pond has been replaced by infiltration basin. e. Keep Sheet L1100 Overall Tract Site Plan. Cross out wet detention pond and note that pond has been replaced by infiltration basin. f. Keep Sheet L1101 Site Layout Plan. Cross out wet detention pond and note that pond has been replaced by infiltration basin. g. Keep Sheet C1101 Utility Layout Plan. Cross out wet detention pond and note that pond has been replaced by infiltration basin. h. Keep Sheet L5101 Site Layout Details. On August 5, 2009, the Governor signed Session Law 2009-406. This law impacts any development approval issued by the Division of Water Quality under Article 21 of Chapter 143 of the General Statutes, which is current and valid at any point between January 1, 2008, and December 31, 2010. The law extends the effective period of any stormwater permit that is set to expire during this time frame to three (3) years from its current expiration date. On August 2, 2010, the Governor signed Session Law 2010-177, which grants an extra year for a total of four (4) years extension. Please note that the expiration date of this permit has been adjusted to reflect this four year extension. Wilmington Regional Oft 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 Phone: 910-796-72151 FAX: 910-350-20041 DENR Assistance:1-877-623-6748 Internet www.newaterqualRy.org An Fnnal Onn—hinity 1 Affirmnfiv Arfinn Fmnlnvar This permit shall be effective from the date of issuance until December 31, 2021, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the conditions listed in this permit regarding the Operation and Maintenance of the BMP(s), recordation of deed restrictions, certification of the BMP's, procedures for changes of ownership, transferring the permit, and renewing the permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system, to record deed restrictions, to certify the BMP's, to transfer the permit, or to renew the permit, will result in future compliance problems. We are forwarding you an approved copy of the revised plans for your files. Please combine the new plan set with the old plans as per instructions noted above. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing by filing a written petition with the Office of Administrative Hearings (OAH). The written petition must conform to Chapter 150B of the North Carolina General Statutes, and must be filed with the OAH within thirty (30) days of receipt of this permit. You should contact the OAH with all questions regarding the filing fee (if a filing fee is required) and/or the details of the filing process at 6714 Mail Service Center, Raleigh, NC 27699-6714, or via telephone at 919-431-3000, or visit their website at www.NCOAH.com. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Steve Pusey, at (910) 796-7215. Sinc9rely, sill O Charles akild P.E. Director Division of Water Quality GDS/sgp: S:1WQS1StormwaterlPermits & Projects120071070727 HD12012 10 permit 070727 cc: Dale Hyatt, PE — McKim & Creed Inc. New Hanover County Building Inspections Beth E. Wetherill, New Hanover County Engineering City of Wilmington Development Services Wilmington Regional Office Stormwater File Pane ?. of State Stormwater Management Systems Permit No. SW8 070727 MOD STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY COMMERCIAL DEVELOPMEN T In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO State Employees' Credit Union SECU — Myrtle Grove 141 Sanders Rd., Wilmington, New Hanover County FOR THE construction, operation and maintenance of one (1) alternative design, infiltration basin in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until December 31, 2021, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described in Section 1.7 of this permit. The stormwater control has been designed to handle the runoff from 171,189 square feet of impervious area. 3. The tract will be limited to the amount of built -upon area indicated in Sections 1.2 and 1.7 of this permit, and per approved plans. The built -upon area for the future development is limited to 100,889 square feet. 4. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded shoving all such required easements, its accordance with the approved plans. 5. The runoff from all built -upon area within the permitted drainage area of this project must be directed into the permitted stormwater control system. Page 3 of 8 State Stormwater Management Systems Permit No. SW8 070727 MOD 6. Per section .1008 (h) of the stormwater rules, the alternative design basin provides excess storage volume for 2.5 times the design storm of 1.5 inches and will infiltrate the volume within 5 days using one half the infiltration rate found in the soils report. Therefore, the basin may be operated without an offline bypass or a level spreader / vegetated filter strip. The deep parts of the wet detention pond will be filled with sand in order to construct a level basin bottom elevation. 7. The following design criteria have been permitted for the infiltration basin and must be provided and maintained at design condition: a. Drainage Area, ycres: Onsite, ft Offsite, ft2: b. Total Impervious Surfaces, ft2: C. Design Storm, inches: d. Basin Depth, feet: e. Bottom Elevation, FMSI : f. Bottom Surface Area, ft g. Bypass Weir Elevation, FMS6: h. Permitted Storage Volume, ft i. Type of Soil: j. Expected Infiltration Rate, in/hr: k. Seasonal High Water Table, FMSL: I. Time to Draw Down, hours: M. Receiving Stream/River Basin: n. Stream Index Number: o. Classification of Water Body: II. SCHEDULE OF COMPLIANCE 5.24 228,254 None 171,189 3.75 (no VFS/offline bypass) 5 33.0 10,870 37.64 70,000 Kureb 16.0 31.0 8.0 Mott Creek / Cape Fear 18-82 "C• Sw" 1. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of bypass structure, infiltration media, flow spreader, catch basins, piping and vegetated filter. a. A clear access path to the bypass structure must be available at all times. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. Page 4 of 8 State Stormwater Management Systems Permit No. SW8 070727 MOD 5. The facilities shall be constructed as shown on the approved plans. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 6. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. 8. Access to the stormwater facilities shall be maintained via appropriate recorded easements at all times. 9. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc- b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area or to the drainage area. e. Further development, subdivision, acquisition, lease or sale of any, all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 10. Prior to the construction of any permitted future areas shown on the approved plans, the permittee shall submit final site layout and grading plans to the Division for approval. 11. A copy of the approved plans and specifications shall be maintained on file by the Permittee at all times. At the time the permit is transferred to a new owner, the permittee shall forward the approved plans to the new owner. 12. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. Page 5 of 8 State Stormwater Management Systems Permit No. SW8 070727 MOD III. GENERAL CONDITIONS 1. This permit is not transferable to any person or entity except after notice to and approval by the Director. At least 30 days prior to a change of ownership, or a name change of the owner or of the project, or a mailing address change, the permittee shall submit a completed and signed Name/Ownership Change form to the Division of Water Quality, accompanied by the supporting documentation as listed on the form. The approval of this request will be considered on its merits and may or may not be approved. 2. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. Neither the sale of the project nor the conveyance of common area to a third party constitutes an approved transfer of the stormwater permit. 3. Any individual or entity found to be in noncompliance with the terms and conditions of this permit or with the requirements of the stormwater rules, is subject to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143, Article 21. 4. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. 5. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 6. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 7. The permit remains in force and effect until modified, revoked, terminated, or renewed. The permit may be modified, revoked and reissued cr terminated for cause. The filing of a request for a permit modification, revocation and reissuance, renewal or termination does not stay any permit condition. 8. Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 9. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 10. The permittee shall submit a permit renewal application at least 180 days prior to the expiration date of this permit. The renewal request must include the appropriate documentation and the processing fee. Permit modified and reissued this the 25t" day of October, 2012. NO TH CAROLINA ENVIRONMENTAL_ MANAGEMENT COMMISSION Tor- Charled Wakild, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Page 6 of 8 Casmer, Jo From: Casmer, Jo Sent: Friday, October 26, 2012 10:48 AM To: 'dhyatt@imckimcreed.com' Subject: SECU Myrtle Grove Attachments: 2012 10 permit 070727.pdf Dale: Steve Pusey indicated you wished to have a copy of the permit modification emailed to you. This is attached. A hard copy (signed) is forthcoming in the mail. Jo Caswer Administrative Assistant IV NC Dept. of Environment & Natural Resources Division of Water Quality -Surface Water Protection Section 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796-7336 Fax: (910) 350-2004 Pease note envii address has &r d. Email correspondence to and from this address may be subjed to the North Carolina Public Records Law and may be disdosed to third parties Cf f 7/7 V Mq<IM&CREED 1730 VARSITY DRIVE, SUITE 500, RALEIGH, NC 27606 TEL (919) 233-8091 - FAX (919) 233-8031 LETTER OF TRANSMITTAL ADDRESS: 127 Cardinal Drive Extension Wilmington, NC 28405 TTENTION: NCDENR DWQ - Wilmington Regional Office Steve Pusey DATE: October 19, 2012 PROJECT #: 01517-0226 TASK #: REIMB RE: SECU Myrtle Grove Modification TRANSMITTAL #: PAGE OF WE ARE SENDING: ® Originals Z Prints ❑ Shop Drawings ❑ Samples ❑ Specifications ® Calculations ❑ Other - Quantity Drawing No. Rev. Description Status 1 Signed and Sealed permit drawings G. Issue Status Code: A. Preliminary B. Fabrication Only . C. For Information D. Bid E. Construction F. For Review & Comments G. For Approval H. See Remarks Action Status Code: 1. No Exceptions Taken 2. Make Corrections Noted 3.Other 4. Amend & Resubmit 5. Rejected - See Remarks REMARKS: If you have any questions, or require additional information, feel free to contact me at (919) 233-8091. Thank you, CC: ECEIVEt OCT 2.2 2012 6Y: McKIM & CREED, INC. Signed Dal -, PE INFILTRATION BASIN DESIGN SECU MYRTLE GROVE Infiltration Basin Project: 01517-0226 Prepared by: DNH Date: 8/20/2012 Drainage area: 228,254 sf Impervious area: 171,189 sf Volume to Catch The First 3.75 Inchs of Runoff. Runoff : Rv = 0.05 + 0.9 * la Simple Method, Schueler la (ac/ac)= 0.750 Rv = 0.725 `` ,,,,1lqWrIt"� A Rf f * * * .� �� '= Volume: V = 3630 P Rv A P = 3.75 in - f Rv = 0.725 037 ..4 A = 5.24 ac .� �j4iruupp�y� OCT 16 2012 BY:-_ SECU MYRTLE GROVE Drawdown Time A. Infiltration Rate: k= 8.00 in/hr B. Infiltration Area A= 10,870 sf C. Volume to Drawdown: V= Cf D. ti otal Draw Down Time T= 0.40 days 1/2 minimum rate reported on soils report area of bottom of basin (elev. 33) Page 2 of 3 T(days) = Volume / (2 * Infiltrating Area * Infiltration Rate) i= - OCT 16 2012 t3Y: a0z s 1 130 i ti r eo 00-40)Ul4�kW O 7 0 G W V F0-x cn O 000 (Pl O Ov ; 00 Un 0g0 00 lO A IV K) Db 00 W W FA V I--% 00 N Ot � —L —L —L —L m OD O Cn W — CO 0 0 0 N V� v C 4 N 00 W O � 00— lr 9 cr) —L —L CO c4 0 O -N V CA V - � y e, � d cn .A W N s O goto N c�a CD CD CD N CD CD a CL a a a a 0 0 0 0 0 0 CD CND N N CD CD O A O fa fa !a O O O O O O CQ ca ca ca ca ca m 0 c 3 r m O m CD GO 0 -h W v MgKIM&CREED 1730 VARSITY DRIVE, SUITE 500, RALEIGH, NC 27606 TEL (919) 233-8091 0 FAX (919) 233-8031 LETTER OF TRANSMITTAL ADDRESS: 127 Cardinal Drive Extension Wilmington, NC 28405 ATTENTION: NCDENR DWQ - Wilmington Regional Office Steve Pusey DATE: October 15, 2012 PROJECT #: 01517-0226 TASK #: REIMB RE: SECU Myrtle Grove Modification TRANSMITTAL #: PAGE OF WE ARE SENDING: ® Originals ® Prints ❑ Shop Drawings ❑ Samples ❑ Specifications ® Calculations ❑ Other — Quantity Drawing No. Rev. Description Status 1 Revised HydroCAD 1-yr 24hr Storm Report G. 1 Signed and Sealed Basin Volume Calculation G. 1 Signed and Sealed Drawdown Calculation G. 1 Signed and Sealed Elevation, Area, Volume Table G. U BY: - Issue Status Code: A. Preliminary B. Fabrication Only C. For Information D. Bid E. Construction F. For Review & Comments G. For Approval H. See Remarks Action Status Code: 1. No Exceptions Taken 2. Make Corrections Noted 3.Other 4. Amend & Resubmit 5. Rejected - See Remarks REMARKS: If you have any questions, or require additional information, feel free to contact me at (919) 233-8091. Thank you, CC: McKIM & CREED, INC. f�2 Signed Ae— Dale�,PE v MqK M&CREED V 1730 VARSITY DRIVE, SUITE 500, RALEIGH, NC 27606 TEL (919) 233-8091 _ FAX (919) 233-8031 LETTER OF TRANSMITTAL ADDRESS: 127 Cardinal Drive Extension Wilmington, NC 28405 ATTENTION: NCDENR DWQ - Wilmington Regional Office DATE: August 20, 2012 PROJECT #: 01517-0226 TASK #: REIMB RE: SECU Myrtle Grove Modification TRANSMITTAL #: PAGE / OF WE ARE SENDING: ® Originals ® Prints ❑ Shop Drawings ❑ Samples ❑ Specifications ® Calculations ❑ Other — Quantity Drawing No. Rev. Description Status 2 Stormwater Management Permit Application Form (1 original, 1 copy) 1 Supplement Form (original) O&M agreement 1 1 Check — permit application processing fee ($505) 1 Narrative with supporting calculations and documentation 2 Sets of plans morRIVE 1 Soils report 1 Copy of most current deed Issue Status Code: A. Preliminary B. Fabrication Only C. For Information D. Bid E. Construction F. For Review & Comments G. For Approval H. See Remarks Action Status Code: 1. No Exceptions Taken 2. Make Corrections Noted 3.Other 4. Amend & Resubmit 5. Rejected - See Remarks REMARKS: Please find the above information enclosed for the State Employees Credit Union Modification in Myrtle Grove, NC. If you have any questions, or require additional information, feel free to contact us at (919) 233-8091. Thank you, ■ CC: McKIM & CREED, INC. Signed STORWATER CALCULATIONS State Employees' Credit Union SECU Myrtle Grove New Hanover County, North Carolina August 20, 2012 Prepared for: North Carolina State Employees' Credit Union Prepared By: McKim & Creed, Inc 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919) 233.8091 Fax: (919) 233.8031 F1222 M&C Project No. 01517-0226 C q R 0 ?O F Z' N. " EpENED AUG 22 2012 gV*.-------� STOR A` ER C ALCULATIO S State Employees' Credit Union SECU Myrtle Grove New Hanover County, North Carolina September 6, 2012 Prepared for: North Carolina State Employees' Credit Union NEW HANOVER COUNTY ENGINEERING DEPARTMENT STORM WATER REGULATION Reviewed for compliance with applicable County Storm Water Policies and regulations. *Approved Prepared By: *Approved as noted. McKim L Creed, Inc 1730 Varsity Drive, Suite 500 *Rcvisc as nosed and resubmit %�'%,,h North Carolina 27606 Review Engine Date: P'7/ f�: (919) 233.8091 Fax: (919) 233.8031 COMPLETE SET OF STAMP APPROVED PI.ANSMUST BEONJOB SITE F1222 UNTILCOMPLETION OF f ROIECT. ANY VARIANCE FROM THE APPROVED PLANS' REQUIRESRestsrfQftjest No. 01517-0226 RYTHE DESIGNER TO THE COUNTYFOR APPROVAL. a,,i,1}iS}}}}:1}e777 •itia,a so i 03, 1 J 1 PECeIVIE ' OCT 01 2012 BY: PROJECT DESCRIPTTON The purpose of this project is to convert an existing wet detention pond to an infiltration basin. No changes in impervious area, storm drainage infrastructure, or new infrastructure are proposed. The existing wet detention pond was approved on ranuary 25, 2008 under NC DWQ permit number SW8070727. The existing forebay berm has eroded twice after rainfall events and the pond does not hold water due to the high infiltration rates of the in situ soil. The site is located at 141 Sanders Road approximately 800 linear teet west of the intersection of US Highway 421 and Sanders Road (SR 1187). SITE DESCRIPTION The existing project area is a 5.47 acre tract consisting of two parcels located in Myrtle Grove, New Hanover County, North Carolina. The parcels share a common wet detention pond on the eastern side of the tract. The western parcel, Lot No. 1, contains a State Employees Credit Union bank and parking lot with storm water infrastructure in place. Lot No. 1 is approximately 2.77 acres and 75% impervious. The eastern parcel, Future Development Area No. 1, is to be developed at a future time. Future Development Area No. 1 is approximately 2.47 acres. The existing pond and stormwater infrastructure are designed for this area to be built out with 75% impervious area (80,694 SF of impervious) at a later date. No impervious area or changes to stormwater infrastructure are proposed for this BMP modification. The site is located in New Hanover County and is in the Cape Fear River basin. SOILS According to the NRCS Web Soil Survey, the majority of uplands within the site are classified as Kureb Sand (Kr). Lynn Haven fine sand (Ly) is also found on the site. The following soil descriptions are associated with the soils found on the tract: Kr - Kureb sand, 1 to 8% slopes Ly- Lynn Haven fine sand STORMWATER IMPROVEMENTS The purpose of this project is to convert an existing wet detention pond to an infiltration basin. The existing wet detention pond was originally permitted in 2008 (SW8070727) and has had problems related to the forebay berm. In order to alleviate those problems, converting the wet detention basin to an infiltration basin has been proposed. The proposed infiltration basin has been overdesigned per the NCDENR Stormwater BMP Manual Chapter 16.3.9. Off line Bypass & Vegetated Filter Strip. The basin provides approximately 58,000 cubic feet storage for 2.5 times the design storm of 1.5 inches and the basin will infiltrate the volume within 5 days using one half the infiltration rate (+/- 8 inches per hour) found in the attached soils report. Based on these criteria, the offline bypass and vegetated filter strip requirements have been waived for the proposed infiltration basin. The total disturbed area for the site will be .96 acres. PLANNED EROSION AND SEDIMENTATION CONTROL PRACTICES 1. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE/EXIT A temporary gravel construction entrance/exit will be installed at the entrance drive to the site to provide a buffer area for construction vehicles to drop their mud and sediment to avoid transporting it onto public roads. 2. SILT FENCE Silt fence will be installed in areas of fill around the perimeter of the site to maintain drainage into temporary diversion ditches. Silt fence will be used in natural outfall areas to prevent any sediment from leaving the site. 3. ENERGY DISSIPATOR A 6prap energy dissipator will be located on the downstream end of the stormwater outlet pipe to slow velocities and prevent scour at the outlet of the infiltration basin. MAINTENANCE CONSIDERATIONS The contractor shall be responsible for seeking permit for any borrow and/or spoil areas not shown on these plans. The Contractor shall be responsible for periodic inspection and maintenance of all temporary erosion control measures and permanent stormwater devices. Any measure that fails to function as intended shall be repaired immediately. SUPPORTING DOCUMENTATION i3i ffli U -.. --- AaJcuvu.I--, -- Aaaauuu..,.. --- Disclaimer: We make no warranties or guarantees regarding the accuracy or completeness of geographic features shown on this map. Spatial accuracy of measurement provided by source agencies can be obtained by contacting me. USDA United States Department of Agriculture NRCS Natural Resources Conservation Service A product of the National Cooperative Soil Survey, a joint effort of the United States Department of Agriculture and other Federal agencies, State agencies including the Agricultural Experiment Stations, and local participants Custom Soil Resource Report for New Hanover County, North Carolina SECU Myrtle Grove August 6, 2012 Contents Preface....................................................................................................................2 Soil'Map..................................................................................................................5 SoilMap ....... :........................................................................................................ 6 Legend..................................................................................................................7 MapUnit Legend..................................................................................................8 MapUnit Descriptions..........................................................................................8 New Hanover County, North Carolina.............................................................10 Kr—Kureb sand, 1 to 8 percent slopes.......................................................10 Ly—Lynn Haven fine sand..........................................................................11 4 Soil Map The soil map section includes the soil map for the defined area of interest, a list of soil map units on the map and extent of each map unit, and cartographic symbols displayed on the map. Also presented are various metadata about data used to produce the map, and a description of each soil map unit. 5 I A w 34" 7' 38" 34" 7' 38" 34- 7' 30" L... 34" 7' 30" 23100 232240 80 232320 232360 232400 23244D 232480 232520 232560 Map Scale: 1:1,810 K printed an A size (8.5" x 11') sheet N Meters 0 25 50 100 150 Feet 0 100 200 400 600 m in O Q 4) Ir co C7 O m N O U) E y U E D7 C W O N C LO N 'C .N E IV 'C - ��Q N �p Y > •O N L •Wp U y V N 'WO O 110 6'E �Cp to :C 2 fp 00 a)CD e-� U m •O- O U U N y L E Q W ctlw a W d N W C n W N N E c00 W n� Z N t 7 U Q O O w O E N O Z N Q C N N W N Q 10 N W Gn. = W W E yO Z CA O O_ C La u� N O N T •p > v W yy 0 0-5 Q. C O ..t. OL = O G 3 O •md a)C EN2aQ Z 3O a + a"N CdOLL E0 o ooa> 9b�� vo E EO Q C m o=E o m aiW.�> bW E mEL Z >,d 4 O WW o r > o:o W cs w C dN N a) N W m �❑ Q E rnT� o o W o Z o fA �Fo W C U �` N w 7 0 W 2 d t c as o W •�NO C lGpj O co to — y •� N W W W �C E+L-' N 0 0 C_ �� O GNj E Q W v = y O W N C y N N N CO 7 Oo a W E m E = W O w E EL d a E O W O W O LoCD m ❑ r 3 o C n Ua N C U � m t � 0 C E w tq Z �' U d v R LL T m o `m { m E m w 'm `o m O m C 0 t 0 O E L U3 c to Z, _J A .Y N �. H.. Ids, W LL y4 O io r i I M i+� r 0 d 3 W .J IL o Q p ¢ o m w a E a a ° 'o w_ vT oaG r a da t` C3 o o. oC m aQ m m Qs ao D m m i °m' O 0 iwi UE 2 rx mo O O. co m m a w mmto n m mo.nCO. m m CL a � Custom Soil Resource Report Map Unit Legend r: `` �i� tioy �llap. r+tl la r :, ► JitAr4 Kr Kureb sand, 1 to 8 percent slopes S A 82.3% Ly Lynn Haven fine sand 1.4 17.7% Totals for Area of Interest 7.8 100.0% Map Unit Descriptions The map units delineated on the detailed soil maps in a soil survey represent the soils or miscellaneous areas in the survey area. The map unit descriptions, along with the maps, can be used to determine the composition and properties of a unit. A map unit delineation on a soil map represents an area dominated by one or more major kinds of soil or miscellaneous areas. A map unit is identified and named according to the taxonomic classification of the dominant soils. Within a taxonomic class there are precisely defined limits forthe properties of the soils. On the landscape, however, the soils are natural phenomena, and they have the characteristic variability of all natural phenomena. Thus, the range of some observed properties may extend beyond the limits defined for a taxonomic class. Areas of soils of a single taxonomic class rarely, if ever, can be mapped without including areas of other taxonomic classes. Consequently, every map unit is made up of the soils or miscellaneous areas for which it is named and some minor components that belong to taxonomic classes other than those of the major soils. Most minor soils have properties similar to those of the dominant soil or soils in the map unit, and thus they do not affect use and management. These are called noncontrasting, or similar, components. They may or may not be mentioned in a particular map unit description. Other minor components, however, have properties and behavioral characteristics divergent enough to affect use or to require different management. These are called contrasting, or dissimilar, components. They generally are in small areas and could not be mapped separately because of the scale used. Some small areas of strongly contrasting soils or miscellaneous areas are identified by a special symbol on the maps. If included in the database for a given area, the contrasting minor components are identified in the map unit descriptions along with some characteristics of each. A few areas of minor components may not have been observed, and consequently they are not mentioned in the descriptions, especially where the pattern was so complexthat itwas impractical to make enough observations to identify all the soils and miscellaneous areas on the landscape. The presence of minor components in a map unit in no way diminishes the usefulness or accuracy of the data. The objective of mapping is not to delineate pure taxonomic classes but rather to separate the landscape into landforms or landform segments that have similar use and management requirements. The delineation of such segments on the map provides sufficient information for the development of resource plans. If intensive use of small areas is planned, however, onsite investigation is needed to define and locate the soils and miscellaneous areas. L Custom Soil Resource Report An identifying symbol precedes the map unit name in the map unit descriptions. Each description includes general facts about the unit and gives important soil properties and qualities. Soils that have profiles that are almost alike make up a soil series. Except for differences in texture of the surface layer, all the soils of a series have major horizons that are similar in composition, thickness, and arrangement. Soils of one series can differ in texture of the surface layer, slope, stoniness, salinity, degree of erosion, and other characteristics that affect their use. On the basis of such differences, a soil series is divided into soil phases. Most of the areas shown on the detailed soil maps are phases of soil series. The name of a soil phase commonly indicates a feature that affects use or management. For example, Alpha silt loam, 0 to 2 percent slopes, is a phase of the Alpha series. Some map units are made up of two or more major soils or miscellaneous areas. These map units are complexes, associations, or undifferentiated groups. A complex consists of two or more soils or miscellaneous areas in such an intricate pattern or in such small areas that they cannot be shown separately on the maps. The pattern and proportion of the soils or miscellaneous areas are somewhat similar in all areas. Alpha -Beta complex, 0 to 6 percent slopes, is an example. An association is made up of two or more geographically associated soils or miscellaneous areas that are shown as one unit on the maps. Because of present or anticipated uses of the map units in the survey area, it was not considered practical or necessary to map the soils or miscellaneous areas separately. The pattern and relative proportion of the soils or miscellaneous areas are somewhat similar. Alpha - Beta association, 0 to 2 percent slopes, is an example. An undifferentiated group is made up of two or more soils or miscellaneous areas that could be mapped individually but are mapped as one unit because similar interpretations can be made for use and management. The pattern and proportion of the soils or miscellaneous areas in a mapped area are not uniform. An area can be made up of only one of the major soils or miscellaneous areas, or it can be made up of all of them. Alpha and Beta soils, 0 to 2 percent slopes, is an example. Some surveys include miscellaneous areas. Such areas have little or no soil material and support little or no vegetation. Rock outcrop is an example. 9 I L. Custom Soil Resource Report New Hanover County, North Carolina Kr—Kureb sand, 1 to 8 percent slopes Map Unit Setting Elevation: 0 to 20 feet Mean annual precipitation: 42 to 58 inches Mean annual air temperature: 61 to 64 degrees F Frost -free period. 190 to 270 days Map Unit Composition Kureb and similar soils: 85 percent Minor components: 5 percent Description of Kureb Setting Landform: Rims on carolina bays, ridges on marine terraces Landform position (two-dimensional): Summit, shoulder Landform position (three-dimensional): Crest Down -slope shape: Convex Across -slope shape: Convex Parent material. Eolian sands and/or sandy fluviomarine deposits :properties and qualities Slope: 0 to 6 percent Depth to restrictive feature: More than 80 inches Drainage class: Excessively drained Capacity of the most limiting layer to transmit water (Ksat). High to very high (5.95 to 19.98 in/hr) Depth to water table: More than 80 inches Frequency of flooding. None Frequency of ponding: None Available water capacity. Very low (about 1.8 inches) Interpretive groups Land capability (nonirrigated): 7s Typical profile 0 to 3 inches: Sand 3 to 26 inches: Sand 26 to 89 inches: Sand Minor Components Leon Percent of map unit: 5 percent Landform: Flats on marine terraces Down -slope shape: Linear Across -slope shape: Concave 10 L Custom Soil Resource Report Ly—Lynn Haven fine sand Map Unit Setting Elevation: 20 to 160 feet Mean annual precipitation: 40 to 55 inches Mean annual air temperature: 59 to 70 degrees F Frost -free period. 200 to 280 days Map Unit Composition Lynn haven, undrained, and similar soils: 85 percent Description of Lynn Haven, Undrained Setting Landfonn: Flats on marine terraces Down -slope shape: Linear Across -slope shape: Linear Parent material.* Sandy fluviomarine deposits and/or eolian sands Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class. Poorly drained Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 6.95 in/hr) Depth to water table: About 0 to 6 inches Frequency of flooding. None Frequency of ponding. None Maximum salinity: Nonsaline (0.0 to 2.0 mmhos/cm) Available water capacity: Moderate (about 8.3 inches) Interpretive groups Land capability (noninigated): 4w Typical profile 0 to 9 inches. Sand 9 to 12 inches. Fine sand 12 to 80 inches: Sand 11 Soil & Environmental. Consultants, PA 11010 Rav= Ridgy Road • Raldgi . NW& Cualma 27614 - Mme (919) 846-5900 • Fax: (919) 846497 www.SendBCcom June 29, 2012 Job # 11893.Sl Obrien Atkins Attn: David Kaiser 5001 S. Miami Blvd. Durham, NC 27703 Re: Detailed soils evaluation adjacent to the existing wet detention basin of the Myrtle Grove State Employee's Credit Union, located off of Sanders Road, New Hanover County, NC. Dear Mr. Kaiser: Soil & Environmental Consultants, PA (S&EC) performed a detailed soil evaluation around the perimeter of the existing wet pond location on the site mentioned above. The purpose of this evaluation was to provide additional information to aid in the stormwater BMP design by providing applicable soil morphological and hydraulic conductivity data. Soil borings were advanced to a depth of 8 to 11 feet from the existing ground surface. The following is a brief report of the methods utilized in this evaluation and the results obtained. Soll/Site Evaluation Methodol The site evaluation was performed by advancing hand auger borings to a depth of 8 to 11 feet from the existing ground surface. Soil morphological conditions were described at each location using standard techniques outlined in the "Field Book for Describing and Sampling Soils" published by the Natural Resources Conservation Service (MRCS, 2002). A detailed soil profile description is included in Attachment 1. Soil/Site Conditions Field investigation revealed that the soils on site are most similar to the Kureb soil series. Kureb series soils are considered excessively drained and rapidly permeable. S&EC identified soil morphological features indicative of a seasonal high water table (SHWT) at a depth of 131" below top of ground (TOG). Based on the existing topography, this depth to SHWT corresponds to an approximate elevation of 31 feet above MSL. Under current NC-DWQ regulations, the bottom of the proposed infiltration basin must be at least 2 feet above the Seasonal High Water Table (SHWT). Hydraulic Conductivity Analysis: Three Saturated hydraulic conductivity (Ksat) measurements were conducted by the constant head well permcameter technique (also known as shallow well pump -in technique and bore hole permeameter method). This procedure is described in Methods of Soil Analysis, Part 1., Chapter 29 — Hydraulic Conductivity of Saturated Soils: Field Methods, 29 — 3.2 Shallow Well Pump In Method, pp. 758-763 and in the Soil Science Society of America Journal, Vol. 53, no. 5, Sept. — Oct. 1989, "A Constant -head Permeameter for Measuring Saturated Hydraulic Conductivity of the Vadose Zone" and "Comparison of the Glover Solution with the Simultaneous — Equations Approach for Measuring Hydraulic Conductivity." In essence, a volume of water was applied and measured with time until a steady state of water flow was achieved. This volumettime with steady state was used to calculate the saturated hydraulic conductivity of the subsoil by the Glover equation. S&EC conducted three Ksat measurements around the perimeter of the existing wet pond. Ksat measurement #1 was conducted at a depth of 91 inches from top of ground while Ksat #2 and Ksat #3 were run at 95 inches and 72 inches from top of ground, respectively. Ksat data calculations/field data are also included in Attachment 3. Measured Ksat Values. Location Testing Depth Soil Texture Ksat (Inlhr) Ksat 1 91" Sandy loam 16.435 Ksat 2 95" Sandy loam 21.365 Ksat 3 7Z1 Sand 22.859 Average= 20.22 Under current NC-DWQ regulations, soils underlying the infiltration basin must have a drainage rate of greater than 0.52 in/hr. Based on measurements collected, the tested underlying soil horizons have an average Ksat of 20.22 in/hr. Based on this data, S&EC believes that the soil horizons that underlie the proposed infiltration basin would have adequate capacity to assimilate storm water at a rate of at least 0.52 in/hr. Soil & Environmental Consultants, PA is pleased to be of service in this matter and we look forward to assisting in the successful completion of the project. If requested, S&EC can meet on -site with NC-DWQ to discuss our findings and recommendations. Please feel free to call with any questions or comments. Sincerely, Soil & Environmental Consultants, P, Dicky Pontello - NC Licensed Soil Scientist #1232 112. Boring Location 1 Horizon 1 Depth (in) 0-6 Horizon Desoistion Matrix Color I OYR 416 Mottle Color Texture: sand St —re st ra►in Moist Consf Brett km$ Horizon 2 De $ in-23 in Horizon Designation A eft Color 7.5YR 616 WOO Color Texture sand Structure si2ole grain WE r> me nce loose Horizon 3 in w - 69 rn Horizon 2Mnatwn, Matrix Color 7 6YR 716 !Mottle Color Texture sand, Structure, sirs le grej .n n—= louse Fs icy sand granddr ... ,. - very friable HorFzodt 5 DOPM in f tIOF Mob* Modle Ccir r __ ext+.er+e Ieafn Sbucturrswow bed{ uw-isrrm- S gea,lti MEN* 118-4.31 n `nation _ Matt Color 10YR 714 Made Teatic+re sand tructurO granular loose Horizon Qesi w Matrix Color SYR fie Mottles Color IOVR 711 T"- re sand Structure granulat wast its loose Attachment 1. Soil Profile Description Project Name. Myrtle Grove SECU Job Number: 11893.S1 Date: Q6126112 Conducted By: RP Depth to seasonal ho der table 131"from TOG HWT eievab+on 31' INFORMATION r Date 6/26/2012 Measurement Conducted S IMP Job Name MYRTLE GROVE §ECU Job Numbe, 11893.51 Weather Condition ,( r Temperature 90 Loc,stim. _ KSAT #7 _ Honzon.�..� C 5 -sce of Water T Value Units Radius of Hole 3.5 crn Depth of Hole 231A4 ImPal Depth of eater in Hwe 'H) 7:62 cm Final Repo of }Nater in Dote (H) 7,62 Ratio Hfr 2,1771; Start ,Saturation T;m 1113 No of Reservoirs Used at Stead tate 2 A factor in Equation (2] of Manual �-Agi ffi� i CIO-ck a[gr LP.YeI! Neadiri TGYI@ tltt@! Va t11Time Minufa Watu Level cm crri 11.16 16.3 11 17 "3.9. 1.IX1 _ 2.� 1 1-18 11 0 1.00 21 11 19 81 1.00 2.S 11.20 15 3 1.00i 2A 1121 26j 1.00 2.x 11.22 t? U 1.00 A Inches Hole Dew: 91 H{inidbo: 3 H{flr�s>�: 3 AVERAGES 246.76,.. 41.74 16.435 � 5� INFORMATION Date 612612012 Measurement Conducted By RP Job Name MYRTLE GROVE SEI U Job Number T 1593. S 1 Weather Condition Clear Temperature 90 IKSAT#2 Loaat:on Horvon kcm, ce � WAter Tara Value Lin c f vd%'-J�6 of Hole 3.5 cm Devith of Hole 241. 3 fiat De0h of Water 7.62 cm utet Depth of 11�at�sr I" - T 62 cm iP�r 2't �'71 0-4188 L f Used at Stead-State�.��+ A tBCtOr in Eq=lffa Inches Hole Depth: H(lnhial): H(flnal): INFORMATION Date 612612012 Measurement Conducted By RP Job Name MYRTLE GROVE SECT! Job Number 11893.81 Weather Condition Clear Temperature 90 Location KSAT #3 Horizon source of Water .T Ta Tatra¢ t lnit Radius of Hole 3.5 cm Depth of Hole 182.88 lttttal Depth of WSW to ia H 7 62 ern l l VIM Water' ut e H . 7.62 cm #�tr 2.t77t � iar( 11.5s a• No, of Reservoirs Used at Steady -State 2 A factor in Equation 121 of Manual - 0.002 Inches Hole Depth: 72 H(lniflal): 3 H(Nnal): 3 - A+VERI�GE�S 3a f z2 58.06 22.t359 B State Stormwat6r Management Systems Permit No. M8 070727 -NKT #06003 & 09009 State Employees. Credit Union - Myrtle Grove office Stornwvater Permit No. SW8 070727 New Hanover County Designer's Certi feation 1, John A. Kuske, III, P.E. , as a duly registered Professional Engineer in the State of North Carolina, haying been authorized to observe (periodically/ weekly! full time) the construction of the project, State Employees' Credit Union - Myrtle Grove Office tProject) for State Employees' Credit Union (Project Qwnbr) hereby state that, to the best of my abiirtfes, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specllicadons. The checklist of items on page 2 of this form Is included in the Certification Noted deviations from approved plans and specification: Signature J. : ` , Registration Date .4. KU '0�l9-Faa Page 6of7 SEAL State Storrnwater Management Systems Permit Ng. SW8 070727 Certification Requirements: -QtQ 1. The drainage area to the system contains approximately the permitted acreage. . 2. The d ramage area to the system contains no more than the permitted amount ofbulk-upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. ING. All roof chains are located such that the runoff is directed into the system. wag 5. The outleUbypass structure elevations are per the approved plan. The outlet structure is located per the approved plans. 7. Trash rack is provided on the outlet/bypass structure. �iL All slopes are grassed with permanent vegetation. 9 Vegetated slopes are no steeper than 3:1. 10. The inlets are ioca6ed per the approved plans and do not cause short- circuiting of the system. dw—, 1.Tihe pad amounts of surface area and/or volume have been" dtfiLRequired drawdown devices -are correctly sued per the approved plans. (3. All required design depths are provided. AN required parts ofthe system are provided, such as a vegetated shelf, and a forebay. The required system dimensions are provided per the approved plans. ccV NCDENR-DWQ Regional Office New Hanover County Building Inspections David Kaiser, RLA, ASLA, LEE} AP / 4Brien Atkins Associates, P.A. JAKIIUasn 05003 & 09M 10-20-09-s-sw-Dart. Page 7 of 7 RSVSl10R ftA WS : $3, 600.01k R07600-006-006-000 Grantee's Mailing Address: FOR REGISTRATION REGISTER OF DEEDS REBECCA P. SMITH NEW HANOVER CWNTY NC 2886 A 27 83 :33 t PIS BK:5857 PG:478-482 FEE:$23.80 NC REV SiP63300A I6MEN1 # ION2570 ft1kned to: Jouph C Hearne, If R07600-006-006-001 State Employees Credit Union 5011 Randall Parkway Wilmington, NC 28403 DRAM BY: CALDER S C&LDER, LLS, 703 Saint Joseph Street, Unit 301, Carolina Beach, NC 28420 (Preparer expresses no opinion on title.) Brief Description: Pt Godwin -Sanders Div Pt and (8.0 Acres) Trl Goodwin -Sanders Pt This deed, made and entered into this, the 26t1�, day of July, 2006, by and between Zzw5a A. M abr uk &ad 9P�LZw, Jaogaralyn J. ]Wbeck, and Walter O. *inter and wife, Leigh linter, the GRANTOR herein; and, State►IMployees Credit Union, the GRANTEE herein. W T T R$ S S R T S: That the Grantor, for and in the consideration of the sum of One Dollar and other valuable consideration, the receipt of which is herebyacknowledged, has and by these presents, does grant, bargain, sell and convey unto the Grantees in fee simple, that real estate located in the County of New Hanover, State of NORTH CAROLINA, more particularly described as follows: SEE ATTACHED EXHIBIT A To have and to hold the aforesaid lot or parcel, together with all privileges and appurtenances thereto, heretofore belonging to the Grantee in fee simple. The Grantor covenants With the Grantee that Grantor is seized of the premises in fee simple, has the right to convey the same in fee simple, that the title is marKetable and free and clear of all encumbrances, and that Grantor will warrant and defend the title against the lawful claims of all persons whomsoever except for the exceptions hereinafter stated. Title to the property herei.nabove described is subject to the following exceptions: The provisions of all applicable zoning and land use ordinances, statutes and regulations; 2006 ad valorem taxes, and all applicable restrictive covenants and utility easements of record. In witness whereof, the Grantor(a) have hereunto set their hands and seals this the day and year first above written.. /6 { SEAL) I nn . SEAL) A. Rttbect Walter 01 Winter��- 32&= of 8 ChR=XKIL C MM oS B IIOVa� I, I I i I U a Notary Public of the County and State afor aid, certify that Bruce A. MWmm:k and wife, iacqpelyn J. Kdbec& personally appeared before me this day, having been identified by a driver's license or other photographic identification, and each acknowledged the voluntary execution of the foregoing instrument for the purposes contained therein and in the capacity stated. Witness my hand andofficial stamp or seal, this the day of July, 2006. V ' ® ? fl?Ali ;o . Typed or pri ted nacre a �$ My Commission Expires: I, a Notary Public of the county and State afordjaid, certify that Walter O. Winter and wife, Leigh Winter personally appeared before me this day, having been identified by a driver's license or other photographic identification, and each acknowledged the voluntary execution of the foregoing instrument for the purposes contained therein and in the capacity stated. Witness my hand and official stamp or seal, this the ,�• zoos. A _. xot�aryi i & lR F-MVE 40f� Typed or printed name Q�fl�Og My Commission Expires: L. MINIT A TRACT' 1: BEGINNING at an old iron pipe in the western right of way line of Carolina Beach Roan (u.S. Highway 421) (80.0 feet from the centerline thereof), said point being the southeastern corner of the Bowen Chapel *2 Pion Church property, said beginning point being South 30 deg. 36 min. best 320.0 feet from an old iron pipe in the dividing line betraen 1 and 2 of the Division of the J. H. McDonald land as shown on a map prepared by E. J. W. Anders, C. E., and duly recorded in Book 285 at Page 304-1/2 of the New Hanover County Registry; said dividing corner being the northeastern corner of Tract i of the Division of Tract 1 of the Division of the J. H. McDonald land as recorded in Map Book 13 at Page 4 of the blew Hanover County Registry; running thence Fran said beginning point, along the western right of way line of said Carolina Beach Road, South 26 deg. 37 min. West 54.2 feet to a right of way m rAment, the beginning of a sight right of way at the intersection of said Carolina Beach Road and S. R. #1187; running thence along saki eight right of way litre, South 57 deg. 17 rein. hest 90.6 feet to a right of way monument at the end of said sight riot of way in the nor" IRM right of way line of said S. R. #1187 (50.0 feet frm the centerline thereof); running thence along the northern right of way line of said S. R. #1181, south 84 deg. 04 min. west 130.0 feet to an iron pipe; running ttaex = North 12 deg. 02 min. 30 sec. East 160.0 feet, to an iron pipe; running thence South 76 deg. 47 gain. 30 sec. East 203.52 feet to the point of beginning, containing 0.53 acres of land, more or less, the same being a portion of aforen►entio®ea Tract 1 of the Division of Tract 1 of the Division of the J. H. McDonald land. And also being that same property conveyed by Hampton Sanders (widow) to Lillie Leonard and husband, Elijah 7,eonard, by deed dated August 15, 1974, and recorded September 5, 1.974, in Boots 1013 at Page 299, of the New F.anover County Registry. Being the same property described in that stead recorded in BOOK 1391r Page 1471, New Hanover County Registry. TRW.T 2: BEGFINMM at a concrete 11Aomzmnt marled "N.S. n which is located in the northern line of Secondary Road #1187 whist) saidd stone marks the southwestern corner of Tract "1" as snom on crap recorded in Map Book 13 at Page 4 in the New Hanover County Registry, whistle said temp is entitles) "Cammiasioners Division Tract #1 Division of the Jr. li. McDonald Land, Federal Point Township, Blew Hanover County, North Carolina, for E. W. Coddin - Hampton Sanders - Xftl.son Sanders* dated Nwwoer 3, 1971 and prepared by M. F. Una rm000, R. L. S. lamming tr=100 fray said beginning point North 6 degrees 01' Nest 285.1 feet to another concrete morANWL marked wK.S."; thence Nortm. 81 degrees 59' Fast 1192.9 feet to a point; thence southwardly 347.75 feet to a point in the northern right of tray li.tn of S. R. #1187 wni.ah is located North 83 degrees 59' Fast 162.2 feet and North 84 degrees East 922.6 feet from the point of beginning; thence South 84 degrees 04' West 922.6 feet to a concrete right of. way Pconent; thence South 93 degrees 59' West 152.2 feet to the point of beginning, the same being the western portion of Tract 1 of the aforeeanticned Commissioners Division. Being the same property described in that deed recorded in Boor 1359, Page 1686, New Hanover County ilegistxy. REBECCA P. SMITH REGISTER OF DEEDS, NEW HANOVER 216 NORTH SECOND STREET WILMINGTON, NC 28401 Filed For Registration: 0712712006 03:33:57 PM Book: RE 5057 Page: 478.482 Document No.: 2006042570 DEED 5 PGS $23.00 NC REAL ESTATE EXCISE TAX: $3,800.00 Recorder: SCOTT, NANCY A State of North Carolina, County of Now Hanover YELLOW PROBATE SHEET IS A VITAL PART OF YOUR RECORDED DOCUMENT. PLEASE RETAIN WITH ORIGINAL DOCUMENT AND SUBMIT FOR RE-RECORDING. *2006042570* 200€042570 SUPPORTING CALCULATIONS 111MMI&I ��& �1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919), License: F-1222 www.mekimcreed.com K W I W W W W W W W W M W W W W W W W W W W Y W W W W W W„ W V• W W W W W W W W W W SANDERS ROAD (S.R- 1187) ,100 PUBLIC 0 60' 120' DATE: AUGUST 2012 MCEMCE PROD#_01517-0226 DRAWN MAM DESIGNED DNH CHECKED DNH PROJ. MGR. ISCALE MZ FILE NIINLiER IHORIZONTAL: oRnwNc NUMBER 1"-60' VERTICAL: NA STATUS: REMypN POINT PRECIPITATION FREQUENCY ESTIMATES .r FROM NOAA ATLAS 14 WILMINGTON 7 N, NORTH CAROLINA (31-9467) 34.3167 N 77.9167 W 32 feet from "Precipitation -Frequency Atlas of the United States" NOAA Atlas 14, Volume 2, Version 3 G.M. Bonr*4 D. Martin, B. Lin, T. Parzybok, M.Yekta, and D. Riley NOAA, National Weather Service, Silver Spring, Maryland, 2004 Extracted: Thu Jul 22 20, 0 Confidence Limits Seasonalky Related Inlo GIS data aWMaps Does-P RetM to State Map 'These precipitation frequency estimates are based on a partial duration series.ARI is the Average Recurrence Interval. Please referto NOMMas 14 Documentfor more information. NOTE: Formatting forces estimates near zero to appear as zero. * Upper bound of the 90% confidence interval _ Precipitation Frequency Estimates (inches) _ ARI**ii �5 YO 15 30 120 3 j 6 f 12 24 48 4 - 7 10 20 30 45 60 11171n lulu i� hr I hr h day day day day day day day f �'ears�iL"""_lL"""11 L"'' !L�J[6? 0.56 s9 1.12 1.53 1.91 2.29 .46 I�OS 3.59 r 4.29 5.03 j 5�70 6.47 7.27 9.65 1 ] .74 14.57 17.44 0.66 i 1.06 1.33 1.84 2.31 2.79 2.99 3.71 4.36 5.21 6.09 6.87 7.81 8.71� 11.5l 13.94 17.22 20.55 i ICi I= 0.78 1.24 1.57 2.23 2.86 3.55 � 3.82 4.75 f 5.63] 6.73 , 8.05� 10.10' 7.81 18.70_I 12.60 9.80� l l .48' g93 (15.05 10.79 12.53 1 14.01 16A7 t 19.02 16.72 18.98 22.12 20.40 , 24.02 22.99 26.77 26.56 30.51 10 0_86 t 0.97 '' 1.38 1.55 1.75 1.97 ` 2.53 2.91 ! 3.29 3.88 IF5.11 4.19 _s 4.5-4 5.64 FF 6.72 8.39 9.30 110.27J 11�.591 25 f 5.60 16.98 b5:0:JE061 1.14 2.13 3.21 3.52 4.35 i 4.85 5.90 6. 66 16.02 18.32 17.21� 19.52 21.49 24.14 24.66 27.32 29.42 33.45 32.39 36.43 6.54� 7.58 8.17] 9.86 9.49 111.54 11.93 14.03a 13.63 ;K64 15.93 16.93 100� 1.82 2.30 ` 200 1.23 11.95 2.46 3.83 5.37 7.69 8.73 _i 10.99j 13.44i 16.41 18.591 19.47 20.82 22.07 27.02 30.12 35.53 39.44 S00 l 1.35 12.13 2.68 4.26 16.42 20.22 122.64 23.60 123.38 26.26E 1 26.84 24.64 27.86 25.8813 29.14 I.17 34.65 34.10 37.28 39.81 43.33 i 43.56 . 46.80 16.12 9.12 10.50 13.29 1000 l .44 .27 i 2.85 j 4.61 16.72 10.37 12.07 15.35 119.03 i no upper oouno ottne commence imervan at aumo connpence ieven is ate venue wnncn 57b ottne simuiama quanite values for a gmen trequencyare greater tnan. "These precipitation frequency estimates are based on a partial duration series. ARI is the Average Recurrence Interval. Please refer to NOAAMas 14 Documentfor more information. NOTE: Formatting pretends estimates nearzero to appear as zero. j� Lower bounds of the 90% confidence interval i Precipitation Frequency Estimates (inches) I ARI** 5 10F15! 3�0 60 1�20 3[h�r 7hr 2�4 48 4 7 10 ( 20 30 45 60 (Years)L"""_1 """�"_'...�L""� mm�Il""f ..- L ' hr day day aay I aay . day ; day.. i� r 1 F648 � 0.77 ; 0.97 11.33 i 1.65 1.94 12.08E 2.57 2.98 i 3.45 14.09 14.63 15.46 ; 6.1 I 18.26 � 10.25 j 12.86 (I 5.48 INFILTRATION BASIN ANALYSIS requires input by reviewer FILENAME: s:lwgslstormwaterlpermits & projects120071070727 HD12012 09 excel IB 070727 PROJECT NUMBER: SW8 070727 First Run Date: 9/18 PROJECT NAME: SECU-Myrtle Grove Last Modified: 03-Oct-12 REVIEWER: S. Pusey Basin 1 I Basin 2 I Basin 3 I Basin 4 I Basin 5 I Basin 6 Receiving Stream Moil Greek River Basin Cape Fear Index Number 18-82 Classification C; SW IMPERVIOUS AREA CALCULATION Buildings Parking & Streets Concrete & SW Other/Future TOTAL VOLUME CALCULATION Drainage Area = Drainage Area (acres) % Impervious, 1= Cc= Rv= SHWT Elev.= Infiltration Rate, In/hr = Bottom Elevation= Bottom Surface Area = Top/Storage Elevation = Top/Storage SA = Design Storm = Design Volume = Total Volume Provided= Storage met at elevation= Time to Draw Down = 9700 54100 6500 100889 171189 0 0 0 0 0 228254 5.24 0.00 0.00 0.00 0.00 0.00 75.00% #DIV/0! #DIV/01 #DIV/01 #DIV/0! #DIV/01 0.05 #DIV/0! #DIV/01 #DIV/01 #DIV/0! #DIV/0! 0.72 #DIV/0! #DIV/01 #DIV/0! #DIV/0! #DIV/0! 31.0 8.0 33 10870 37.64 18250 3.75 51713 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! I 67558 0 0 0 0 0 36.55 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/01 7.14 #DIV/0! #DIV/01 #DIV/0! #DIV/0! #DIV/0! APF-11i COMMENTS Volume and drawdown are (not) within. Design Requirements. Cc sf sf acres msl n/hr msl >f msl if in cf cf fmsl hrs. days Pre -Development 3S Post -Development 4P Proposed Infiltration Basin S4 Reach on Link IItt11111l1111►/!�, ••,,,•�� N -GAR ''���"', 037894 _ Pil OCT 16 2012 Myrtle Grove Type H/ 24-hr 1-YR Rainfall=3.81" Prepared by McKim & Creed ,Printed 10/15/2012 HydroCAD® 9.10 s/n 03870 02010 HydroCAD Software Solutions LLC Page 5 Time span=0.00-48.00 hrs, dt=0.01 hrs. 4801 points Runoff by SCS TR-20 method, UH=SCS Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Subcatchment 1S: Pre -Development Runoff Area=5.240 ac 0.00% Impervious Runoff Depth=0.00" Flow Length=430' Tc=44.9 min CN=30 Runoff=0.00 cfs 0.000 of Subcatchment 3S: Post -Development Runoff Area=5.240 ac 75.00% Impervious Runoff Depth=2.12" Flow Length=950' Tc=4.7 min CN=83 Runoff=13.67 cfs 0.927 of Pond 4P: Proposed Infiltration Basin Peak Elev=34.59' Storage=19,971 cf Inflow=13.67 cfs 0.927 of Discarded=1.18 cfs 0.926 of Primary=0.00 cfs 0.000 of Secondary=0.00 cfs 0.000 of Outflow=1.18 cfs 0.926 of Total Runoff Area = 10.480 ac Runoff Volume = 0.927 of Average Runoff Depth = 1.06" 62.50% Pervious = 6.550 ac 37.50% Impervious = 3.930 ac Myrtle Grove Type 11124-hr 1-YR Rainfall=3.81" Prepared by McKim & Creed Printed 10/15/2012 HydroCAD® 9.10 s/n 03870 02010 HydroCAD Software Solutions LLC . Page 6 Summary for Subcatchment 1S: Pre -Development [45] Hint: Runoff=Zero Runoff = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Depth= 0.00" Runoff by 5C5 TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hr 1-YR Rainfall=3.81" Area (ac) CN Description 5.240 30 Woods, Good, HSG A 5.240 100.00% Pervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 43.0 300 0.0200 0.12 Sheet Flow, Sheet Flow Woods: Light underbrush n= 0.400 P2= 4.62" 1.9 130 0.0540 1.16 Shallow Concentrated Flow, Shallow Concentrated Flow Woodland Kv= 5.0 fps 44.9 430 Total Subcatchment'IS: Pre -Development Hydrograph iic Runoff 0.00 Ors Type III 24-h r 1 YR Rail: fall=3.81'" Run®ff Area=5.240 arc Runoff Volume=0.000 of Runoff :Depth=0.00, Flow Length=430' 70=44.9 m i n CN=30 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32.. 34 36 38 40 42 44 46 48 Time (hours) Myrtle Grove Type 11124-hr 9-YR Rainfall=a89" Prepared by McKim & Creed Printed 10/15/2012 HydroCAD® 9.10 s/n 03870 ©2010 HydroCAD Software Solutions LLC Page 7 Summary for Subcatchment 3S: Post -Development Runoff = 13.67 cfs @ 12.07 hrs, Volume= 0.927 af, Depth= 2.12" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hr 1-YR Rainfall=3.81" Area (ac) CN Description 3.930 98 impervious 1.310 39 open space good condition (A soil) 5.240 83 Weighted Average 1.310 25.00% Pervious Area 3.930 75.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 1.0 70 0.0100 1.17 Sheet Flow, Sheet Flow Smooth surfaces n= 0.011 P2= 4.62" 3.7 880 0.0030 3.94 12.39 Pipe Channel, Pipe Flow 24.0" Round Area= 3.1 sf Perim= 6.3' r= 0.50' n= 0.013 3 0 LL 4.7 14 12 1� 11 1C 950 Total Subcatchment 3S: Post -Development Hydrograph -------------------------•--------------------. -- - 73.67eh '..e-. T; a III 24 -hr 1 YR Yp - 5 4 " 3' 2 " ..., rainfall=3.91ee ---- ----- ----- ------ ----- Runoff-Area=5,240--ad-- Rl n ff VOIUme-0-�927- of-- Runoff.Depfh - Flow Len jth=9 - - -- 50' TCX4.'7 tn i n CN=83 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) Runoff Myrtle Grove Type/1/ 24-hr 9-YR Rainfall=3.89" Prepared by McKim & Creed Printed 10/15/2012 HydroCAD® 9.10 s/n 03870 ©2010 HydroCAD Software Solutions LLC Page 8 Summary for Pond 4P: Proposed Infiltration Basin Inflow Area = 5.240 ac, 75.00% Impervious, Inflow Depth = 2.12" for 1-YR event Inflow = 13.67 cfs @ 12.07 hrs, Volume= 0.927 of Outflow = 1.18 cfs @ 13.07 hrs, Volume= 0.926 af, Atten= 91 %, Lag= 59.9 min Discarded = 1.18 cfs @ 13.07 hrs, Volume- 0.926 of Primary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 of Secondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 of Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Peak Elev= 34.59' @ 13.07 hrs Surf.Area= 13,982 sf Storage= 19,971 cf Plug -Flow detention time= 252.2 min calculated for 0.926 of (100% of inflow) Center -of -Mass det. time= 252.1 min ( 1,075.9 - 823.8 ) Volume Invert Avail.Storage Storage Description #1 33.00' 87,025 cf Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 33.00 10,869 0 V 34.00 13,079 11,974 11,974 35.00 14,607 13,843 25,817 36.00 16,148 15,378 41,195 37.00 17,715 16,932 58,126 38.00 19,338 18,527 76,653 38.50 22,150 10,372 87,025 Device Routing Invert Outlet Devices #1 Discarded 33.00' 16.000 in/hr Exfiltration over Surface area above 33.00' Conductivity to Groundwater Elevation = 0.00' Excluded Surface area = 10,869 sf #2 Primary 37.64' Special & User -Defined Head (feet) 0.00 0.06 0.16 0.26 0.36 0.46 0.56 0.66 0.76 0.86 Disch. (cfs) 0.000 0.710 3.070 6.360 10.370 14.980 20.120 25.740 29.830 30.210 #3 Secondary 38.14' 20.0' long x 10.0' breadth Broad -Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 Discarded OutFlow Max=1.18 cfs @ 13.07 hrs HW=34.59' (Free Discharge) +�1=Exfiltration ( Controls 1.18 cfs) Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=33.00' (Free Discharge) �2=Special & User -Defined ( Controls 0.00 cfs) Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=33.00' (Free Discharge) t3=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) Myrtle Grove Type 11124-hr 1-YR Rainfall=3.81" Prepared by McKim & Creed Printed 10/15/2012 HydroCAD® 9.10 s/n 03870 02010 HydroCAD Software Solutions LLC Page 9 Pond 4P: Proposed Infiltration Basin Hydrograph --------------------------------- -------- --------------- LI-I.Discarded w 13s� ers Outflow - 1f1=�4r=5:240-a .. ------------ --- ----- ------ ------------------------------------ - ----•- -- ,y4 ary15 ' Peak-Elev=34.a9'... ondary 14 13 " ; - " - Storage=l 9,;971 d 12 10 -- --- ----------- --------------- --............... ------- ---------- ---- - 9 ------------------ ------ ------------. ... 8 . ----.- ---- - -- --- ---- ----------- --- -- ----- --- LL 6 -- --- 5 4 riffs 3- 2, - .. 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) Pussy, Steven From: Pusey, Steven Sent: Friday, October 12, 201211:52 AM To: Dale Hyatt (dhyatt(amckimcreed.com) Subject: Request for Addlnfo - SECU Project Dale, After final review of the application for this state stormwater permit SW8 070727, we have one additional request. We need for you to provide a revised copy of the HydroCAD printouts with the 1-yr, 24 hr storm pre and post. Previously, your HydroCAD data sheet listed primary overflow elevation at 37.0' when it actually should be 37.64 as shown on your SMP supplement page. Please make this correction to your HydroCAD program and submit the revised data sheets ASAP. If you have any questions or comments, please don't hesitate to call. I will set a deadline for one week from today, or Oct.19, 2012. This should wrap things up so we can provide a permit. Thanks, Steve Crfavaft 0. A Environmental Engineer NCDENR - Div. of Water Quality Surface Water Protection Ph (910) 796-7334 / Fax (910) 350-2004 Before printing this email, please consider your budget and the environment E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. v MCKIM&CREED ENGINEERS V SURVEYORS P L A N N E R S September 28, 2012 Steve G. Pusey NCDENR — DWQ Wilmington Regional 127 Cardinal Drive Extension mv7CIFIVE Wilmington, NC 28405 •° Subject: Request for Additional Information Stormwater Project No. SW8 070727 MOD gyp State Employees' Credit Union New Hanover County Dear Mr. Pusey: In response to your comments dated September 19, 2012, we provide the following responses below in RED: 1. Please adjust the latitude and longitude shown on page 1 of the application such that it's in the center of the main entrance. Latitude & longitude have been adjusted and a revised page 1 has been included with this submittal. 2. The maximum runoff to each inlet of the infiltration basin shall not exceed 2 acre -inches. Please reference Section 16.3.3 in the BMP manual. ` #a 16.3.3 also states exceptions to the 2-acre inch runoff maximum. Borings and visual site inspections indicate that the water table does not fluctuate over the area of the infiltration basin and the width of the basin is no more than twice the length of a "long reach" backhoe. A long reach backhoe will be required Venture I V Building to reach all parts of the infiltration basin given the design of the original wet Site 500 pond. Additionally the large rip -rap pretreatment area should prohibit erosion of the inlet. 1 730 Varsity Drive /3. Please locate each BMP and all swales in access/drainage easements and show their width. Raleigh, NC 27606 Access/drainage easements have been extended to include entire BMP. Easement lines have been dimensioned, labeled, and added to the legend on sheets C-101 and C-102. 919.2 3 3.8091 Fax 919.233.8031 www.mckimcreed.com -k% A4� /�, /vt C.IC r ., , `,. — e .. ;I State Employees' Credit Union September 28, 2012 Stormwater Application No. SW8 070727 4. Please show property / project boundary lines, bearings, and distances on the plans. Property lines, bearings, and distances have been shown on sheets C-101 and C-102. 5. Please show 3: 1 side slopes on the infiltration basin sectim detail. 3(H):1(V) side slopes have been shown on both infiltration basin section details on sheet C-501. 6. Please show the dimensions for each line and arc formed by the bottom contour of an infiltration basin. An exhibit has been included with this submittal that dimensions each line that forms the 33' MSL contour (bottom contour of infiltration basin). 7. Please remember that a change to one number may have a domino effect on other numbers. Please check all plans, calculations and forms and make changes as needed. Revised plans and supporting documentation/calculations have been included based upon the above comments and comments received from New Hanover County. If you have any questions during your review, please do not hesitate to give me a call at 919.233.8091. Thank you. Sincerely, McKIM & CREED, Inc. Dale Hyatt, PE, LEED AP Project Engineer EI OCT 01 2012 BY: -41 McIQM&CREED NORTH CAROLINA STATE EMPLOYEES CREDIT UNION MYRTLE GROVE, NC SUPPORTING STORM114ATER CALCULATIONS PREPARED BY: MCKIIVI & CREED, INC 1730 VARSITY DRIVE SUITE 500 RALEIGH, NC 27607 PHONE: (919)233-8091 FAX: (919)233-8031 NC# F-1222 NEW HANOVER COUNTY ENGINEERING DEPA*Wk&PROJECT #01 51 7-0218 STORM WATER REGULATION Reviewed for coinpliance with applicable County Storm Water Policies and ngblations: � *Approved *Approved as awed «Revise as noted and :rcsubmit Review En COMP m seT Old S,�A D APPROVED PLANS MUST BE ON J08 SITE UNTIL COMPLETION OF FROJECP. ANY VARIA14CE FROMTHEAPPROVED PLANS REQUIRES RESUBMI71TAL BY THE DESIG M TO THECOUNTY FOR APPROVAL. Pre -Development z S . C3, Z� Post -De lopment 4P \ Proposed Infiltration Basin I C_Subcat� EReachl Ink Drainage Diagram for Myrtle Grove Prepared by McKim & Creed, Printed 9/6/2012 HydroCAD® 9.10 s/n 03870 0 2010 HydroCAD Software Solutions LLC -YEAR, PRE -DEVELOPMENT Myrtle Grove Type Ill 24-hr 1-YR Rainfall=3.81" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®910 s/n 03870 ® 2010 HydroCAD Software Solutions LLC Page 5 Time span=0.00-48.00 hrs, dt=0.01 hrs, 4801 points Runoff by SCS TR-20 method, UH=SCS Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Subcatchment 1S: Pre -Development Runoff Area=5.240 ac 0.00% Impervious Runoff Depth=0.00" Flow Length=430' Tc=44.9 min CN=30 Runoff=0.00 cfs 0.000 of Subcatchment 3S: Post -Development Runoff Area=5.240 ac 75.00% Impervious Runoff Depth=2.12" Flow Length=950' Tc=4.7 min CN=83 Runoff=13.67 cfs 0.927 of Pond 4P: Proposed Infiltration Basin Peak Elev=34.59' Storage=19,971 cf Inflow=13.67 cfs 0.927 of Discarded=1.18 cis 0.926 of Primary=0.00 cfs 0.000 of Secondary=0.00 cfs 0.000 of Outflow=1.18 cfs 0.926 of Total Runoff Area = 10.480 ac Runoff Volume = 0.927 of Average Runoff Depth =1.06" 62.60% Pervious = 6.550 ac 37.60% Impervious = 3.930 ac Myrtle Grove Type Ill 24-hr 1-YR Rainfall=3. 81 " Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Pape 6 Summary for Subcatchment 1S: Pre -Development [45] Hint: Runoff=Zero Runoff = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Depth= 0.00" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hr 1-YR Rainfall=3.81" Area (ac) CN Description 5.240 30 Woods, Good, HSG A 5.240 100.00% Pervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 43.0 300 0.0200 0.12 Sheet Flow, Sheet Flow Woods: Light underbrush n= 0.400 P2= 4.62" 1.9 130 0.0540 1.16 Shallow Concentrated Flow, Shallow Concentrated Flow Woodland Kv= 5.0 fps 44.9 430 Total Subcatchment 1S: Pre -Development Hydrograph Runoff Type III 24-h r 1-YR Rainfall=3.91" Runoff Area=5.240 ac Runoff Volume=0.000 of Runoff Depth=0.00" Flow Length=430' Tc=44.9 m i n CN=30 G 2 4 0 a 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) -YEAR, POST -DEVELOPMENT Myrtle Grove Type /// 24-hr 1-YR Rainfall=3.81" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 7 Summary for Subcatchment 3S: Post -Development Runoff = 13.67 cfs @ 12.07 hrs, Volume= 0.927 af, Depth= 2.12" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hr 1-YR Rainfall=3.81" Area (ac) CN Description * 3.930 98 impervious * 1.310 39 open space good condition (A soil) 5.240 83 Weighted Average 1.310 25.00% Pervious Area 3.930 75.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 1.0 70 0.0100 1.17 Sheet Flow, Sheet Flow Smooth surfaces n= 0.011 P2= 4.62" 3.7 880 0.0030 3.94 12.39 Pipe Channel, Pipe Flow 24.0" Round Area= 3.1 sf Perim= 6.3' r= 0.50' n= 0.013 4.7 950 Total Subcatchment 3S: Post -Development doro9roph o. 15 14 _ 1367.Cfs !. -- 13 Type III 24-hr 1-YR 12 Rainfall=3.81" 11 Runoff Area-=5.2240--ac 10 Runoff Volume=0.927 of in 9 - ---Runoff Depth=2: 8 ......... 0 7 Flow Length=950' LL 6 Tc=4.7 m i n 5 �m ww'� V N=83 4 3 0 1 4 fi 8 10 12 i4 16 i8 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) ■ Runoff Myrtle Grove Type 111 24-hr 1-YR Rainfall=3.81" Prepared by McKim & Creed Printed 9/6/2012 HVdroCADO 9.10 s/n 03870 ® 2010 HydroCAD Software Solutions LLC Page 8 Summary for Pond 4P: Proposed Infiltration Basin Inflow Area = 5.240 ac, 75.00% Impervious, Inflow Depth = 2.12" for 1-YR event Inflow = 13.67 cfs @ 12.07 hrs, Volume= 0.927 of Outflow = 1.18 cfs @ 13.07 hrs, Volume= 0.926 af, Atten= 91%, Lag= 59.9 min Discarded = 1.18 efs @ 13.07 hrs, Volume= 0.926 of Primary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 of Secondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 of Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Peak Elev= 34.59' @ 13.07 hrs Surf.Area= 13,982 sf Storage= 19,971 cf Plug -Flow detention time= 252.2 min calculated for 0.926 of (100% of inflow) Center -of -Mass det. time= 252.1 min (1,075.9 - 823.8 ) Volume Invert Avail Storage Storage Description #1 33.00' 87,025 cf Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 33.00 10,869 0 0 34.00 13,079 11,974 11,974 35.00 14,607 13,843 25,817 36.00 16,148 15,378 41,195 37.00 17,715 16,932 58,126 38.00 19,338 18,527 76,653 38.50 22,150 10,372 87,025 Device Routing Invert Outlet Devices ti Discarded 33.00' 16.000 in/hr E011tration over Surface area above 33.00' e?Conductivity to Groundwater Elevation = 0.00' f, Excluded Surface area = 10,869 sf #2 Primary 37.00' Special & User -Defined Head (feet) 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 --� - 1.00 1.10 1.20 1.30 1.40 1.50 Disch. (cfs) 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.710 3.070 6.360 10.370 14.980 20.120 25.740 29.830 30.210 #3 Secondary 38.14' 20.0' long x 10.0' breadth Broad -Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 iscarded OutFlow Max=1.18 cfs @ 13.07 hrs HW=34.59' (Free Discharge) =Exfiltration ( Controls 1.18 cis) Primary OutFlow Max=0.00 cfs @ 0.00' hrs HW=33.00' (Free Discharge) '-2=Special & User -Defined (Controls 0.00 cfs) Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=33.00' (Free Discharge) t3=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) Myrtle Grove Type 111 24-hr 1-YR Rainfall=3.89" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD89 10 s/n 03870 02010 HydroCAD Software Solutions LLC Page 9 0 3 0 LL Pond 4P: Proposed Infiltration Basin i ime tnours) Inflow El Outflow 9 Discarded II Primary C2 Secondary 2-YEAR, PRE -DEVELOPMENT Myrtle Grove T -2- Prepared by McKim & Creed Printed 9/6/2012 HydroCADO 9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 5 Time span=0.00-48.00 hrs, dt=0.01 hrs, 4801 points Runoff by SCS TR-20 method, UH=SCS Reach routing by Stor-Ind+Trans method - Pond routing by 5tor-Ind method Subcatchment 1S: Pre -Development Runoff Area=5.240 ac 0.00% Impervious Runoff Depth=0.00" Flow Length=430' Tc=44.9 min _ Runoff=0.00 cfs 0.000 of Subcatchment 3S: Post -Development Runoff Area=5.240 ac 75.00% Impervious Runoff Depth=2.83" Flow Length=950' Tc=4.7 min Runoff=18.19 cfs 1.237 of Pond 413: Proposed Infiltration Bain Peak Elev=35.00' Storage=25,882 cf Inflow=18.19 cfs 1.237 of Discarded=1.96 cfs 1.237 of Primary=0.00 cfs 0.000 of Secondary=0.00 cfs 0.000 of Outflow=1.96 cfs 1.237 of Total Runoff Area = 10.480 ac Runoff volume = 1.237 of Average Runoff Depth = 1.42" 62.50% Pervious = 6.550 ac 37.60% Impervious = 3.930 ac Myrtle Grove Type 111 24-hr 2-YR Rainfall=4.62" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 6 Summary for Subcatchment 1S: Pre -Development (45] Hint: Runoff=Zero Runoff = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Depth= 0.00" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hr 2-YR Rainfall=4.62" Area (ac) CN Description 5.240 30 Woods, Good HSG A 5.240 100.00% Pervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 43.0 300 0.0200 0.12 Sheet Flow, Sheet Flow Woods: Light underbrush n= 0.400 P2= 4.62" 1.9 130 0.0540 1.16 Shallow Concentrated Flow, Shallow Concentrated Flow Woodland Kv= 5.0 fps 44.9 430 Total Subcatchment 1S: Pre -Development Hydrograph Runoff Type III 24-hr 2-YR Rainfall=4.62" Runoff Area=5.240 ac Runoff Volume=0.000 of Runoff Depth=0.00" U. Flow Length=430" 1 Tc=44.9 m i n GN=30 0 2 4 6 8 i0 12 14 16 16 20 22 24 26 28 30 32 3A 36 38 40 42 44 46 Time (hours) 2-YEAR, POST -DEVELOPMENT Myrtle Grove Type 8124-hr 2-YR Rainfall=4.62" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 7 Summary for Subcatchment 3S: Post -Development Runoff = 18.19 cfs @ 12.07 hrs, Volume= 1.237 af, Depth= 2.83" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hr 2-YR Rainfall=4.62" Area (ac) CN Description 3.930 98 impervious 1.310 39 open space good condition (A soil) 5.240 83 Weighted Average 1.310 25.00% Pervious Area 3.930 75.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) , (ft/sec) (cfs) 1.0 70 0.0100 1.17 Sheet Flow, Sheet Flow Smooth surfaces n= 0.011 P2= 4.62" 3.7 880 0.0030 3.94 12.39 Pipe Channel, Pipe Flow 24.0" Round Area= 3.1 sf Perim= 6.3' r= 0.50' n= 0.013 4.7 950 Total Subcatchment 3S: Post -Development Hydrograph 181 I Type-11-124-hr 2-YR 1 16 Rainfall=4.62" 15 Runoff Area=5.240 ac 14 13 Runoff Volume=1.237 of 12 11 Runoff -Depth=2:33 LL 19 Flow Length=950° 8 - Tc=4.7 ruin ----- CN=33 U 2 4 6 8 10 12 14 16 18 2�0 22 24 2G 28 30 32 34 36 38 40 42 44 46 48 Time (hours) Myrtle Grove Type ill 24-hr 2-YR Rainfall=4.62" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD09 10 s/n 03870 ©2010 HydroCAD Software Solutions LLC Page 8 Summary for Pond 4P: Proposed Infiltration Bain Inflow Area = 5.240 ac, 75.00% Impervious, Inflow Depth = 2.83" for 2-YR event Inflow = 18.19 cfs @ 12.07 hrs, Volume= 1.237 of Outflow = 1.96 cfs @ 12.82 hrs, Volume= 1.237 af, Atten= 89%, Lag= 44.8 min Discarded = 1.96 cfs @ 12.82 hrs, Volume= 1.237 of Primary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 of Secondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 of Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Peak Elev= 35.00' @ 12.82 hrs Surf.Area= 14,614 sf Storage= 25,882 cf Plug -Flow detention time= 213.3 min calculated for 1.236 of (100% of inflow) Center -of -Mass det. time= 213.4 min ( 1,028.9 - 815.5) Volume Invert Avail Storage Storage Description #1 33.00' 87,025 cf Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 33.00 10,869 0 0 34.00 13,079 11,974 11,974 35.00 14,607 13,843 25,817 36.00 16,148 15,378 41,195 37.00 17,715 16,932 58,126 38.00 19,338 18,527 76,653 38.50 22,150 10,372 87,025 Device Routing Invert Outlet Devices #1 Discarded 33.00' 16.000 in/hr Exfiltration over Surface area above 33.00' Conductivity to Groundwater Elevation = 31.00' Excluded Surface area = 10,869 sf 2 Primary 3".0C Special & User -Defined Head (feet) 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 Disch. (cfs) 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.710 3.070 6.360 10.370 14.980 20.120 25.740 29.830 30.210 43 38.14' 20.0' long x 10.0' breadth Broad -Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 Discarded OutFlow Max--1.96 cfs @ 12.82 hrs HW=35.00' (Free Discharge) 't--1=Exfiltration ( Controls 1.96 cfs) Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=33.00' (Free Discharge) 't--2=Special & User -Defined ( Controls 0.00 cfs) §condary OutFlow Max=0.00 cfs @ 0.00 hrs HW=33.00' (Free Discharge) 3=Sroad-Crested Rectangular Weir ( Controls 0.00 cfs) Myrtle Grove Type 11124-hr 2-YR Rainfall=4.62" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 ©2010 HydrOCAD Software Solutions LLC Page 9 Pond 4P: Proposed Infiltration Bain Hydrograph M Inflow tatscrs C:`.' Ouil. Inflow ac �'°iscarded rea=5.240 0, Primary 20 Peak EIev=35.00' Secondary 19 18 Storage=25,882 cf 17 16 15 14 13 ....... y 12 11 3 10 _. 0 9 - - LL 8 7 5 1.96 cfs 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) 0-YEAR, PRE -DEVELOPMENT Myrtle Grove Type rrr 18" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD® 9.10 s/n 03870 ©2010 HydroCAD Software Solutions LLC Page 10 Time span=0.00-48.00 hrs, dt=0.01 hrs, 4801 points Runoff by SCS TR-20 method, UH=SCS Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Subcatchment 1S: Pre -Development Runoff Area=5.240 ac 0.00% Impervious Runoff Depth=0.24" Flow Length=430' Tc=44.9 min CN=30 Runoff=0.18 cfs 0.107 of Subcatchment 3S: Post -Development Runoff Area=5.240 ac 75.00% Impervious Runoff Depth=5.20" Flow Length=950' Tc=4.7 min D iv=83 Runoff=32.76 cfs 2.270 of Pond 4P: Proposed Infiltration Rain Peak Elev=36.45' Storage=48,573 cf Inflow=32.76 cfs 2.270 of Discarded=3.63 cfs 2.269 of Primary=0.00 cfs 0.000 of Secondary=0.00 cfs 0.000 of Outflow=3.63 cfs 2.269 of Total Runoff Area = 10.480 ac Runoff volume = 2.376 of Average Runoff Depth = 2.72" 62.50% Pervious = 6.560 ac 37.50% Impervious = 3.930 ac Myrtle Grove Type Ill 24-hr 10-YR Rainfall= 7.18 " Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 11 Summary for Subcatchment 1S: Pre -Development Runoff = 0.18 cfs @ 14.32 hrs, Volume= 0.107 af, Depth= 0.24" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type Ill 24-hr 10-YR Rainfall=7.18" Area (ac) CN Description 5.240 30 Woods, Good, HSG A 5.240 100.00% Pervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 43.0 300 0.0200 0.12 Sheet Flow, Sheet Flow Woods: Light underbrush n= 0.400 P2= 4.62" 1.9 130 0.0540 1.16 Shallow Concentrated Flow, Shallow Concentrated Flow Woodland Kv= 5.0 fps _ 44.9 430 Total Subcatchment 1S: Pre -Development Hydrograph 0.19 0.18 O.ts cfs ... _ .. . 0.17 Type III 24-hr 10-YR 0.16 Rainfall=7.18"- 0.15 A 0.14 --- - Runoff Area=5.240 ac 0.13 0.12 Runoff Volume=0.107 of Oo; Runoff -Dep#h=0.24" LL o.09 Flow Length=430° 0.08 0.07 Tc=44.9 ruin 0.06 ...... --CN=30 0.05 ' n na 0.01 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) Runoff 0-YEAR, POST -DEVELOPMENT Myrtle Grove Type Ill 24-hr 10-YR Rainfall=7.18" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 12 Summary for Subcatchment 3S: Post -Development Runoff = 32.76 cfs @ 12.07 hrs, Volume= 2.270 af, Depth= 5.20" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hr 10-YR Rainfall=7.18" Area (ac) CN Description 3.930 98 impervious 1.310 39 open space good condition (A soil) 5.240 83 Weighted Average 1.310 25.00% Pervious Area 3.930 75.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) _ 1.0 70 0.0100 1.17 Sheet Flow, Sheet Flow Smooth surfaces n= 0.011 P2= 4.62" 3.7 880 0.0030 3.94 12.39 Pipe Channel, Pipe Flow 24.0" Round Area= 3.1 sf Perim= 6.3 r= 0.50' n= 0.013 4.7 950 Total Subcatchment 3S: Post -Development Hydrograpt. Runoff 32 - Type III 24-hr 10-YR 30 Rainfall=7.13" 28 26 Runoff Area-=5r240 .ac 24 Runoff Volume=2.270 of 22 20 Runoff Depth=5.20°' 18 Flow Length=950' 14 Tc=4.7 m i n 12 ,CN=93 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) Myrtle Grove Type 111 24-hr 10-YR Rainfall=7.18" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 ©2010 HydroCAD Software Solutions LLC Page 13 Summary for Pond 4P: Proposed Infiltration Bain Inflow Area = 5.240 ac, 75.00% Impervious, Inflow Depth = 5.20" for 10-YR event Inflow = 32.76 cfs @ 12.07 hrs, Volume= 2.270 of Outflow = 3.63 cfs @ 12.72 hrs, Volume= 2.269 af, Atten= 89%, Lag= 39.3 min Discarded = 3.63 cfs @ 12.72 hrs, Volume= 2.269 of Primary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 of Secondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 of Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Peak Elev= 36.45' @ 12.72 hrs Surf.Area= 16,849 sf Storage= 48,573 cf Plug -Flow detention time= 217.5 min calculated for 2.269 of (100% of inflow) Center -of -Mass det. time= 217.7 min ( 1,016.0 - 798.3 ) Volume Invert Avail Storage Storage Description #1 33.00' 87,025 cf Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 33.00 10,869 0 0 34.00 13,079 11,974 11,974 35.00 14,607 13,843 25,817 36.00 16,148 15,378 41,195 37.00 17,715 16,932 58,126 38.00 19,338 18,527 76,653 38.50 22,150 10,372 87,025 Device Routinq Invert Outlet Devices #1 Discarded 33.00' 16.000 in/hr Exfiltration over Surface area above 33.00' Conductivity to Groundwater Elevation = 31.00' Excluded Surface area = 10,869 sf #2 Primary '' ^"' Special & User -Defined Head (feet) 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 Disch. (cfs) 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.710 3.070 6.360 10.370 14.980 20.120 25.740 29.830 30.210 #3 19ry .1 20.0' long x 10.0' breadth Broad -Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 Discarded OutFlow Max=3.63 cfs @ 12.72 hrs HW=36.45' (Free Discharge) '1-'-1=Exfi1tration ( Controls 3.63 cfs) Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=33.00' (Free Discharge) "�--2=Speciai & User -Defined ( Controls 0.00 cfs) Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=33.00' (Free Discharge) L3=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) Myrtle Grove Type 1/124-hr 10-YR Rainfall=7.18" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD09 10 s/n 03870 ©2010 HydroCAD Software Solutions LLC Pape 14 Pond 4P: Proposed Infiltration Bain Hydrograph 20 i 18 LL 16 14 12 10 8 6 flow InflowArea=5.240 ac Lrinw arded ary Peak Elev=36.45' ondary Storage=46,573 cf 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) 25-YEAR, PRE -DEVELOPMENT Myrtle Grove "" YR `i f . ^ „ Prepared by McKim & Creed Printed 9/6/2012 HydroCADO 9.10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 15 Time span=0.00-48.00 hrs, dt=0.01 hrs, 4801 points Runoff by SCS TR-20 method, UH=SCS Reach routing by Stor-Ind+Trans method - Pond routing by 5tor-Ind method Subcatchment 1S: Pre -Development Runoff Area=5.240 ac 0.00% Impervious Runoff Depth=0.68" Flow Length=430' Tc=44.9 min Runoff=0.88 cfs 0.299 of Subcatchment 3S: Post -Development Runoff Area=5.240 ac 75.00% Impervious Runoff Depth=6.96" Flow Length=950' Tc=4.7 min Runoff=4323 cfs 3.037 of Pond 4P: Proposed Infiltration Bain Peak Elev=37.40' Storage=65,320 cf Inflow=43.23 cfs 3.037 of Discarded=4.86 cfs 3.037 of Primary=0.00 cfs 0.000 of Secondary=0.00 cfs 0.000 of Outflow=4.86 cfs 3.037 of Total Runoff Area = 10.480 ac Runoff Volume = 3.336 of Average Runoff Depth = 3.82" 62.50% Pervious = 6.550 ac 37.50% Impervious = 3.930 ac Myrtle Grove Type/1/ 24-hr 25-YR Rainfall=9.02" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 16 Summary for Subcatchment 1 S: Pre -Development Runoff = 0.88 cfs @ 12.92 hrs, Volume= 0.299 af, Depth= 0.68" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hr 25-YR Rainfall=9.02" Area (ac) CN Description 5.240 30 Woods, Good, HSG A 5.240 100.00% Pervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 43.0 300 0.0200 0.12 Sheet Flow, Sheet Flow Woods: Light underbrush n= 0.400 P2= 4.62" 1.9 130 0.0540 1.16 Shallow Concentrated Flow, Shallow Concentrated Flow Woodland Kv= 5.0 fps 44.9 430 Total 0.9 " 0.85 0.8 0.75 0.7 0.65 0.6 _. w 0.55 v 0.5 0 0.45 LL 0.4 0.35 0.3 0.25 " 0.2 0.15 0.1 0.05 0 0 2 4 6 Subcatchment 1S: Pre -Development Type Ill 24-h r 25-YR Rainfall=9.02" Runoff Area=5.240 ec Runoff Volume-0.299 of Runoff Depth 0.68" Flow Length=430' Tc=44.9 to i n ... Clot=30 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) Runoff 25-YEAR, POST -DEVELOPMENT Myrtle Grove Type 11124-hr 25-YR Rainfall=9.02" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 17 Summary for Subcatchment 3S: Post -Development Runoff = 43.23 cfs @ 12.07 hrs, Volume= 3.037 af, Depth= 6.96" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hr 25-YR Rainfall=9.02" Area (ac) CN Description * 3.930 98 impervious * 1.310 39 open space good condition (A soil) 5.240 83 Weighted Average 1.310 25.00% Pervious Area 3.930 75.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (fi/sec) (cfs) 1.0 70 0.0100 1.17 Sheet Flow, Sheet Flow Smooth surfaces n= 0.011 P2= 4.62" 3.7 880 0.0030 3.94 12.39 Pipe Channel, Pipe Flow 24.0" Round Area= 3.1 sf Perim= 6.3' r= 0.50' n= 0.013 4.7 950 Total Subcatchment 3S: Post -Development Hydrograph ■ Runoff 44 - ype h - 42 TI 1 124 r 25-YR 40 Rainfal-1=9002".. 38 36 34 Runoff Area=5.240 ac- 32 30 Runoff Volume=3.037-af 26 Runoff Depth=6.96°° 24 Flow heng-t-h=950' LL 20 16 ... Tc=4.7 min 14 CN=83 U 2 4 6 8 10 1?.. i4 i6 i8 20 22 24 2G 28 30 32 34 3fi 38 4Q 42 44 ?6 48 Time (hours) Myrtle Grove Type 111 24-hr 25-YR Rainfall=9.02" Prepared by McKim & Creed Printed 9/6/2012 HydroCADO 9.10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 18 Summary for Pont! 4P: Proposed Infiltration Bain Inflow Area = 5.240 ac, 75.00% Impervious, Inflow Depth = 6.96" for 25-YR event Inflow = 43.23 cfs @ 12.07 hrs, Volume= 3.037 of Outflow = 4.86 cfs @ 12.68 hrs, Volume= 3.037 af, Atten= 89%, Lag= 36.9 min Discarded = 4,86 cfs @ 12.68 hrs, Volume= 3.037 of Primary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 of Secondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 of Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Peak Elev= 37.40' @ 12.68 hrs Surf.Area= 18,362 sf Storage= 65,320 cf Plug -Flow detention time= 219.2 min calculated for 3.037 of (100% of inflow) Center -of -Mass det. time= 219.1 min ( 1,009.4 - 790.3 ) Volume Invert Avail Storage Storage Description #1 33.00' 87,025 cf Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 33.00 10,869 0 0 34.00 13,079 11,974 11,974 35.00 14,607 13,843 25,817 36.00 16,148 15,378 41,195 37.00 17,715 16,932 58,126 38.00 19,338 18,527 76,653 38.50 22,150 10,372 87,025 Device Routing Invert Outlet Devices - #1 Discarded 33.00' 16.000 in/hr Exfiltration over Surface area above 33.00' Conductivity to Groundwater Elevation = 31.00' Excluded Surface area = 10,869 sf #. Primary _ Special & User -Defined Head (feet) 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 Disch. (cfs) 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.710 3.070 6.360 10.370 14.980 20.120 25.740 29.830 30.210 #3 ry .` _0.0' long x 10.0' breadth Broad -Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 Discarded OutFlow Max=4.86 cfs @ 12.68 hrs HW=37.40' (Free Discharge) 't--1=Exflltration ( Controls 4.86 cfs) Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=33.00' (Free Discharge) L2=Special & User -Defined ( Controls 0.00 cfs) Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=33.00' (Free Discharge) 3=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) Myrtle Grove Type i1124-hr 25-YR Rainfall=9.02" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HVdroCAD Software Solutions LLC Pape 19 Pond 4P: Proposed Infiltration Bain Hydrograph 43.E d5 Inflow Area=6.240 ac Peak Elev=37.40' 45 Storage=66,320 cf 40 35 _ 30 u �• 25 LL 20 15 ! 4.86 ci8 10 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) 50-YEAR, PRE -DEVELOPMENT Myrtle Grove 1 24- 'YR Rom- 1 /,. Prepared by McKim & Creed Printed 9/6/2012 HydroCADO 9.10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 5 Time span=0.00-48.00 hrs, dt=0.01 hrs, 4801 points Runoff by SCS TR-20 method, UH=SCS Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Subcatchment 1S: Pre -Development Runoff Area=5.240 ac 0.00% Impervious Runoff Depth=1.23" Flow Length=430' Tc=44.9 min d4vft Runoff=2.15 cfs 0.536 of Subcatchment 3S: Post -Development Runoff Area=5.240 ac 75.00% Impervious Runoff Depth=8.55" Flow Length=950' Tc=4.7 min CN=83 Runoff=52.57 cfs 3.735 of Pond 4P: Proposed Infiltration Bain Peak Elev=38.20' Storage=80,561 cf Inflow=52.57 cfs 3.735 of !_ _A 2.142 of &gOOn&Wy=O_e S cfs 0.008 of Outflow=20.62 cfs 2.150 of Total Runoff Area=10.480 ac Runoff Volume = 4.271 of Average Runoff Depth = 4.89" 62.50% Pervious = 6.560 ac 37.50% Impervious = 3.930 ac 4i N0 T rr IA ;- 1595%A Myrtle Grove Type 11124-hr 50-YR Rainfall=10.67" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 6 Summary for Subcatchment 1 S: Pre -Development Runoff = 2.15 cfs @ 12.82 hrs, Volume= 0.536 af, Depth= 1.23" Runoff by SOS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hr 50-YR Rainfaii=10.67" Area (ac) CN Description 5.240 30 Woods, Good, HSG A 5.240 100.00% Pervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 43.0 300 0.0200 0.12 Sheet Flow, Sheet Flow Woods: Light underbrush n= 0.400 P2= 4.62" 1.9 130 0.0540 1.16 Shallow Concentrated Flow, Shallow Concentrated Flow Woodland Kv= 5.0 fps 44.9 430 Total Subcatchment 1S: Pre -Development Hydrograph Runoff --- + Type III 24-hr--50-YR 2 Rainfall=10.67" Runoff Area=5.240 ac Runoff Volume=0.536 of Runoff Depth=1.23" LL Flow Length=430e 1 c=44.6 min CN=30 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) 50-YEAR, POST -DEVELOPMENT Myrtle Grove Type 111 24-hr 50-YR Rainfall= 10. 67" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 7 Summary for Subcatchment 3S: Post -Development Runoff = 52.57 cfs @ 12.07 hrs, Volume= 3.735 af, Depth= 8.55" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hi 50-YR Rainfall=10.67" Area (ac) CN Description 3.930 98 impervious 1.310 39 open space good condition (A soil) 5.240 83 Weighted Average 1.310 25.00% Pervious Area 3.930 75.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 1.0 70 0.0100 1.17 Sheet Flow, Sheet Flow Smooth surfaces n= 0.011 P2= 4.62" 3.7 880 0.0030 3.94 12.39 Pipe Channel, Pipe Flow 24.0" Round Area= 3.1 sf Perim= 6.3' r= 0.50' n= 0.013 4.7 950 Total Subcatchment 3S: Post -Development Runoff 50 Type III 24-hr 50-YR Rainfalt=1 0.67 45 Runoff Area=5.240 ac 40 Runoff Volume=3.735 of 35 Runoff Depth=8.55'A 30 LL 25 Flow Length=950' Tc=4.7 m i n 20 CN=83 0 ?. 4 6 8 i0 i2 i4 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 4A 48 'time (hours) Myrtle Grove Type Ill 24-hr 50-YR Rainfall= 10. 67" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 ©2010 HydroCAD Software Solutions LLC Page 8 Summary for Pond 4P: Proposed Infiltration Bain Inflow Area = 5.240 ac, 75.00% Impervious, Inflow Depth = 8.55" for 50-YR event Inflow = 52.57 cfs @ 12.07 hrs, Volume= 3.735 of Outflow = 20.62 cfs @ 12.27 hrs, Volume= 2.150 af, Atten= 61 %, Lag= 12.1 min Primary = 19.94 cfs @ 12.27 hrs, Volume= 2.142 of Secondary = 0.68 cfs @ 12.27 hrs, Volume= 0.008 of Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Peak Elev= 38.20' @ 12.27 hrs Surf.Area= 20,443 sf Storage= 80,561 cf Plug -Flow detention time= 219.0 min calculated for 2.149 of (58% of inflow) Center -of -Mass det. time= 113.4 min ( 898.1 - 784.7 ) Volume Invert Avail Storage Storage Description #1 33.00' 87,025 cf Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 33.00 10,869 0 0 34.00 13,079 1 1,974 11,974 35.00 14,607 13,843 25,817 36.00 16,148 15,378 41,195 37.00 17,715 16,932 58,126 38.00 19,338 18,527 76,653 38.50 22,150 10,372 87,025 Device Routing Invert Outlet Devices #1 Primary 37..0Y Special & User -Defined Head (feet) 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 Disch. (cfs) 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.710 3.070 6.360 10.370 14.980 20.120 25.740 29.830 30.210 #2 38. 1 4' 20.0' long x 10.0' breadth Broad -Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 Primary OutFlow Max=19.94 cfs @ 12.27 hrs HW=38.20' (Free Discharge) �-1=Special & User -Defined (Custom Controls 19.94 cfs) Secondary OutFlow Max=0.67 cfs @ 12.27 hrs HW=38.20' (Free Discharge) 't-2=13road-Crested Rectangular Weir (Weir Controls 0.67 cfs @ 0.59 fps) Myrtle Grove Type /// 24-hr 50-YR Rainfall=10.67" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 9 Pond 4P: Proposed Infiltration Bain Hydrograph Inflow Area-5.240 ac 55 Peak Elev=38.20° 50 45 Storage=80,561 cf 40 35 u 3 30 , 2o.e2 ch 0 25 19 94 ers 20 15 ' 10 eFeC, - - 0 , .... , .... ,� ;-- � :-.-.- :-: �-rr*+,y-*r„-r+-T�; ' ' .. , . _..::• • . :. ;:;,�-::� . :.42.. ...46 48 4. . 0 2 4 6 8 10 12 14 16 18 20 22 2416 28 30 32 34 36 38 404 Time (hours) G Inflow Outflow Primary Secondary 100-YEAR, PRE -DEVELOPMENT Myrtle Grove Prepared by McKim & Creed Printed 9/6/2012 HydroCAD® 9.10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Pape 5 Time span=0.00-48.00 hrs, dt=0.01 hrs, 4801 points Runoff by SCS TR-20 method, UH=SCS Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Subcatchment 1S: Pre -Development Runoff Area=5.240 ac 0.00% Impervious Runoff Depth=1.98" Flow Length=430' Tc=44.9 min - Runoff=4.15 cfs 0.865 of Subcatchment 3S: Post -Development Runoff Area=5.240 ac 75.00% Impervious Runoff Depth=10.37" Flow Length=950' Tc=4.7 min `� - Runoff=63.04 cfs 4.527 of Pond 4P: Proposed Infiltration Bain Peak Elev=38.46' Storage=86,116 cf Inflow=63.04 cfs 4.527 of Pffttv fs 2.805 of ,yam, 4 cfs 0.137 of Outflow=39.19 cfs 2.942 of Total Runoff Area = 10.480 ac Runoff Volume = 6.393 of Average Runoff Depth = 6.18" 62.50% Pervious = 6.650 ac 37.50% Impervious = 3.930 ac Myrtle Grove Type Ill 24-hr 100-YR Rainfall=12.53" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 6 Summary for Subcatchment 1S: Pre -Development Runoff = 4.15 cfs @ 12.77 hrs, Volume= 0.865 af, Depth= 1.98" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hr 100-YR Rainfall=12.53" Area (ac) CN Description 5.240 30 Woods, Good HSG A 5.240 100.00% Pervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 43.0 300 0.0200 0.12 Sheet Flow, Sheet Flow Woods: Light underbrush n= 0.400 P2= 4.62" 1.9 130 0.0540 1.16 Shallow Concentrated Flow, Shallow Concentrated Flow Woodland Kv= 5.0 fps 44.9 430 Total Subcatchment 1S: Pre -Development Hydrograph Runoff 4 - Type III 24-hr 100-YR Rainfall=12.53i' Ru_n.off Area__=5.240 . asp . - 3 Runoff Volume=0.865 of Runoff ®e.pth=1.98" LL 2 plow Leingth=430° Tc=44.9 rn i n CN=30 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 A.0 42 44 4 Time (hours) 00-YEAR, POST -DEVELOPMENT Myrtle Grove Type 111 24-hr 100-YR Rainfall=12.53" Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 7 Summary for Subcatchment 3S: Post -Development Runoff = 63.04 cfs @ 12.07 hrs, Volume= 4.527 af, Depth=10.37" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Type III 24-hr 100-YR Rainfall=12.53" Area (ac) CN Description 3.930 98 impervious 1.310 39 open space good condition (A soil) 5.240 83 Weighted Average 1.310 25.00% Pervious Area 3.930 75.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) -- 1.0 70 0.0100 1.17 Sheet Flown, Sheet Flow Smooth surfaces n= 0.011 P2= 4.62" 3.7 880 0.0030 3.94 12.39 Pipe Channel, Pipe Flown 24.0" Round Area= 3.1 sf Perim= 6.3' r= 0.50' n= 0.013 4.7 950 Total Subcatchment 3S: Post -Development Hydrograph Runoff 60 Type III 24-hr 100-YR 55 Rainfall=12.53'r 50 Runoff Area=5.240 ac 45 -Runoff Votume=4.527. af.. 40 Runoff Depth=10.37" 3 35 LL 30 Flow Length=950' 25 Tc::4..7A�m i In 20 C N=53 0 2 4 68 10 12 i4 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Time (hours) Myrtle Grove Type 11124-hr 100-YR Rainfall= 12.53 " Prepared by McKim & Creed Printed 9/6/2012 HydroCAD®9 10 s/n 03870 © 2010 HydroCAD Software Solutions LLC Page 8 Summary for Pond 4P: Proposed Infiltration Bain Inflow Area = 5.240 ac, 75.00% Impervious, Inflow Depth = 10.37" for 100-YR event Inflow = 63.04 cfs @ 12.07 hrs, Volume= 4.527 of Outflow = 39.19 cfs @ 12.15 hrs, Volume= 2.942 af, Atten= 38%, Lag= 5.2 min Primary = 30.05 cfs @ 12.15 hrs, Volume= 2.805 of Secondary = 9.14 cfs @ 12.15 hrs, Volume= 0.137 of Routing by Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.01 hrs Peak Elev= 38.46' @ 12.15 hrs Surf.Area= 21,918 sf Storage= 86,116 cf Plug -Flow detention time= 192.5 min calculated for 2.942 of (65% of inflow) Center -of -Mass det. time= 94.4 min ( 874.0 - 779.6 ) Volume Invert Avail Storage Storage Description #1 33.00' 87,025 cf Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 33.00 10,869 0 0 34.00 13,079 11,974 11,974 35.00 14,607 13,843 25,817 36.00 16,148 15,378 41,195 37.00 17,715 16,932 58,126 38.00 19,338 18,527 76,653 38.50 22,150 10,372 87,025 Device Routing Invert Outlet Devices 91 ,- 0 r nary :3 .t Special & User -Defined Head (feet) 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 Disch. (cfs) 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.710 3.070 6.360 10.370 14.980 20.120 25.740 29.830 30.210 #2 Seocovd 3R.IN 20.0' long x 10A' breadth Broad -Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2,69 2.68 2.69 2.67 2.64 Primary OutFlow Max=30.05 cfs @ 12.15 hrs HW=38.46' (Free Discharge) L1=Special & User -Defined (Custom Controls 30.05 cfs) Secondary OutFlow Max=9.08 cfs @ 12.15 hrs HW=38.46' (Free Discharge) t--2=13road-Crested Rectangular Weir (Weir Controls 9.08 cfs @ 1.43 fps) ` ���� ' r' 1�0sl�f Myrtle Grove Type Ill 24-hr 100-YR Rainfall=12.53" Prepared by McKim & Creed Printed 9/6/2012 HydroCADO 9 10 s/n 03870 ©2010 HydroCAD Software Solutions LLC Page 9 Pond 4P: Proposed Infiltration Bain Hydrograph .63.04 crs Inflow Area=5.240 ac 70 65 Peak Elev=38.46° ' Storage=86,1 6 d 5560 50 ` 39 49 cis ' 45 w 40 3 35 30.05are a 30 ' 1 1 . .. 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 Time (hours) J Inflow L- Outflow 0 Primary Secondary SUPPORTING CALCULATIONS NEW HANOVER COUNTY ENGINEERING DEPARTMENT STORM WATER REGULATION Reviewed for compliance with applicable County Storm Water Policies and regulations. *Approved *Approved as noted *Revise as noted and r_°suhmit Review Engin Date: COMPLETE SETOF STAM DAPI'R()Vf:DPLANS MUSREONJOB SITE UNTILCOM!" -., I ION OF FROIEX T. ANY VARIANCE FROM THE APPRt )Vlil) PI . ANS ki QUIRLS RESUBMiTTAL BY THE DESIGNER Ta t'I'1IF. C'OUN'rY FOR APPROVAL. �, 11 t j j I ,NE -�.. -_';.__ ENT 1 0;0,0 :o-o'.o.o'.oio�oo oo,o,olo!o�o'o 1 O O'O O O O;O I�,co V' co • r 1 WiQ'!- O O.O h O'M M 07 to W,N O'O'O O 0:010 O M�fO -N. C-C NjM M h I cs71. 01 M cO' O V o0 N I to0 v) cl1T (9 ftilW O M,. Q. aN 1r ' .� a.� �t;� 1(]I1fJ u]IC] o!Ln a O:O O O'. O' 0. O.O!O i - co W:N 'a N to W'VI co; ..•- * u M v v wr) usm;(o r� r r ao co Wwlo N N:N N'N N,N NIN;N N N,N 0414 M -W l- NNlcD u-jLo:m: IV -W iiOD'OO;N .� O-O;O O 0O1O N N'cD'In �U)'{LI O IaD; O:W cO. N.Iz.ciii 0 0 0 0 0'0 0 �M M'v,Ln!Lo:co m,n I pco - 1 'W O'O O O!O O;O IP!c, M M In O N UOlOO-UcU Of`O,,M - tp'� tD Eu- O o:or� (o co 1 I I r m LM I i r I I Eli iuN3 J';U— , i I i u N OO'01O80 O -Ir.(G M-OOi+� h.OD�N N:� 91) Q1,J�O '� - 1— V O.O O.O O'C-O Oe"f (O.�Ir N N.N!M - -T 'r co M"O.O --f——";-WI(D co w3 M ! O N'M'O : - - iC0 t0 4 o 9 :O O'O'O'O`O O O O'O O', O'1O O pp-O O'�•N'e"f-V N M.QiLa _ o o!o 0 Ci 0;0 0 o a - d r .Z. �. -O.O.O O pp pp 010 O�O O O O?O O O M,<'1(1 cO!A_OD WA' N�M`� 10 ' O Oil u: Q ' W; O - �J 'a)Lu C .a. jN -n'n:n IA.1�'I� P AEh:1,:OD:OD�aOaD'CD W M-MM,P7!M M rf; M;PI' M M, MM M. M'M a.ij �; C4Y (7 IL,II J¢ J, RA 6; :. ; . .p ;-. 0,; p. iE. * �i'N;U Nid:�-a O•U•O; 1—L'.Z �:J U:�;O In Z; C;N, Uc 0 01 a Culvert Calculator Report 24" Outlet Solve For. Headwater Elevation Culvert Summary Allowable HW Elevation 0.00 ft Headwater Depth/Height 1.52 Computed Headwater Elev. 36.34 ft Discharge 20.59 cfs Inlet Control HW Elev. 36.34 ft Tailwater Elevation 0.00 ft Outlet Control HW Elev. 36.22 ft Control Type Inlet Control Grades Upstream Invert 33.30 ft Downstream Invert 32.86 ft Length 55.50 ft Constructed Slope 0.007928 ft/ft Hydraulic Profile Profile M2 Depth, Downstream 1.63 ft Slope Type Mild Normal Depth 1.68 ft Flow Regime Subcritical Critical Depth 1.63 ft Velocity Downstream 7.52 #A Critical Slope 0.008394 Wit Section Section Shape Circular Mannings Coefficient 0.013 Section Material Concrete Span 2.00 ft Section Size 24 inch Rise 2.00 ft Number Sections 1 Outlet Control Properties Outlet Control HW Elev. 36.22 ft Upstream Velocity Head 0.83 ft Ke 0.50 Entrance Loss 0.41 ft Inlet Control Properties Inlet Control HW Elev. 36.34 ft Flow Control Submerged Inlet Type Square edge w/headwall Area Full 3.1 ft= K 0.00980 HDS 5 Chart 1 M 2.00000 HDS 5 Scale 1 C 0.03980 Equation Form 1 Y 0.67000 Project Engineer dhyatt untitled.cvm McKim & Creed Raleigh Master CuivertMester v3.3 [03.03.00.041 09/06/12 09:13:239ki8entley Systems, Inc. Haestad Methods Solution Center Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 New York DOT Dissipator Method For Use in Defined ,Channel - (soumc;: ' B=& and cnzsu-,el lm=q s auY s° , Xtw Ycrl_ De r w of T: gortxbou, Divri;,i a of Desimr m-Ad Cormuwa-t;eu, lt?1.) Guide to Color Key: sw 1..u(Oeia . fCalcutoted. Value . AO". M9 t Designed By: Dale Hyatt Date: 9/(2012 Checked By: Grant Lwartgt od Date: 915/2012 Company: MC IMA acre Project Name: Afiyrge Grave Project No • fO17-0226 Site Location (Cityfrown) M rffeQ ve.Ne. Culvert Id. 2d" BasinC?vilot Estimation of Stone Size and Dimensions For Culvert Aprons 5.:� f) Ca�i�Sts t2�.^ a•�'acaty to 2t Culrer8 cr F'-•- e3 rI �aate:_ step 2) i~'a: ts� ct ltwntk 13. is Ak= ei-. V41 JT .R& S.^'Cs, citi.F2 aLd bw. Cif : eft4 a f: c v c.i C�:. Ezi C?i' .•:5- D. = A. -c.i ele_ = sues -seen! men offiow a1 w va rrt Fcz amdtsple ase F.1, = i _1s` ,x D. Qf=2[f; CU:Ve;._ Velocity (ft/s) 7;2 Opening type Pipe Culvert Single or multiple openings? Single Outlet pipe diameter, Do (ft) 2 NOTE 1: If opening type is anything other than "Pipe Culvert', Da Ao (Cross -sectional area of flow at outlet). NOTE 2: If multiple openings, Do 1.25 x Do of single culvort. sLa 3j Fe e�,orz Vie° �f it:aa cs c :r-�da, r�c�•�- :.-sz�� Zone 2 Will apron have >/=10% grade? No NOTE: For apron slopes equal to or greater than 10%, use next higher Zone in Figure 6.06d to determine apron length. Apron length (ft) 1:2. tl+ Figure 8.06d: Length of Apron APRON MATERIAL LeNGTH OF APFM TO PROTECT Li TO PREVEW SCOJR WUE USE L2 AUMYS L2 STONE MM-2 TWAE1 CL. A 3 x 0, 4 x D, jSTONE FDj-M wMM CL a 3X0, 6 x El. S71:A4,-r-IwILI-M3(MMKW-jcL I 4XD, i3 x 4 a 9ZME FMXWG (HEAVY) CL. I 4X� SX0, 5 C-MONEMUM.4(MAVY) CL-2 5 x D, 10 6 x D" J 10 x 4,1' . EC.URED (ENERGY OMOMTOW STLUING 7 CL9F-C;'c tT;J,7,,F W,M OR "RGERSAM NOTS: For apron slopes equal to or greater than 10%, user ext higher Zone to determine Apron Length. [Retum to fAWn-Wgr—kSt v MCII&CREED V 1730 VARSITY DRIVE, SUITE 500, RALEIGH, NC 27606 TEL (919) 233-8091 0 FAX (919) 233-8031 LETTER OF TRANSMITTAL 127 Cardinal Drive Extension Wilmington, NC-28405 ATTENTION: NCDENR DWQ - Wilmington Regional Office Christine Nelson DATE: September 4, 2012 PROJECT #: 01517-0226 TASK #: REIMB RE: SECU Myrtle Grove Modification TRANSMITTAL #: PAGE OF WE ARE SENDING: ® Originals ® Prints ❑ Shop Drawings ❑ Samples ❑ Specifications ® Calculations ❑ Other — Quantity Drawing No. Rev. Description Status 2 Stormwater Management Permit Application Form (1 original, 1 copy) G. 1 O&M agreement G. C r E 11 F Issue Status Code: A. Preliminary B. Fabrication Only C. For Information D. Bid E. Construction F. For Review & Comments G. For Approval H. See Remarks Action Status Code: 1. No Exceptions Taken 2. Make Corrections Noted 3.Other 4. Amend & Resubmit 5. Rejected - See Remarks REMARKS: . If you have any questions, or require additional information, feel free to contact us at (919) 233-8091 Thank you, CC: McISI�.�I & CREED, INC. Signed D Hyatt, PE Completeness Review Checklist Project Name: (A� -� PIZ> �+ Received Date: ��Zz f Z Project Location: ® 6-n 4,- ;/wu Accepted Date: Q%j j a' Rule(s) F-12008 Coastal 95 Coastal FlPhase II (WiRO) Universal 01988 Coastal Type of Permit: New or o or PR Existing Permit # (Mod or PR):,5&* O 7t-.27 �PE Cert on File? Density: D or LD Type: Commercial or Residential E3NCG: %: ___O(% 00) Stream Class: EISA Map 00ffsite to SW8 Subdivided?: Subdivision or Single Lot II rIORW Map I r IExempt I Pape ork Emailed Engineer on: Supplements) (1 original per BMP) BMP Type(s): Mao, M with correct/original signatures (1 original per BMP except LS/VFS and swales) ®Application with correct/original signatures OCorp or LLC: Sig. Auth. per SoS or letter Note to Reviewer: ®$505 (within 6mo) S�alculations s Report with SHWT (signed/sealed) 131robvious errors Weedensity includes common areas, etc Restrictions, if subdivided: igned & Notarized S�f r pia lac�7�'r•Gki��'� �, A/AAAzi e tlso"'OCorrect Template (Comm/Res & HD/LD) or Dec. Covenants & Rest Plans Sets O�Yetlancls: tails (roads, cul-de-sacs, curbs, sidewalks, BMPs, Buildings, etc) D1615 ing Delineated or No Wetlands Map ®Layout (proposed BUA dimensions) �DA Maps El Project Boundaries Infiltration Wet Pond Offsite Soils Report MSoils Report MPE Cert for Master Lot #: SHWT: SHWT: MDeed Rest for Master Lot # Matches Master Bottom: PP: BUA Permitted (Master): sf Visited: BUA Proposed (Offsite): sf Additional Information: Permitted BUA (sf) DA (sf) PP (el) SHWT (el) Depth (ft) SA (sf) Pro ��, DELI � North Carolina Department of Environment and Natural Division of Water Quality Beverly Eaves Perdue Charles Wakild, P. E. Governor Director September 19, 2012 Bobby Hall, Executive Vice President State Employees' Credit Union P.O. Box 27685 Raleigh, NC 27611 Subject: Request for Additional Information Stormwater Project No. SW8 070727 MOD State Employees' Credit Union New Hanover County Dear Mr. Hall: Resources Dee Freeman Secretary The Wilmington Regional Office received and accepted a modified State Stormwater Management Permit Application for State Employees' Credit Union on September 5, 2012. A preliminary in-depth review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. Please adjust the latitude and longitude shown on page 1 of the application such that it's in the center of the main entrance. 2. The maximum runoff to each inlet of the infiltration basin shall not exceed 2 acre -inches. Please reference Section 16.3.3 in the BMP manual. 3. Please locate each BMP and all swales in access/drainage easements and show their width. 4. Please show property / project boundary lines, bearings, and distances on the plans. 5. Please show 3:1 side slopes on the infiltration basin section detail. 6. Please show the dimensions for each line and arc formed by the bottom contour of an infiltration basin. 7. Please remember that a change to one number may have a domino effect on other numbers. Please check all plans, calculations and forms and make changes as needed. Please note that this request for additional information is in response to a preliminary review. The requested information should be received in this Office prior to October 19, 2012, or the application will be returned as incomplete. The return of a project will necessitate resubmission of all required items, including the application fee. Wilmington Regional Office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 Phone: 910-796-72151 FAX- 910-350-20041 DENR Assistance:1-877-623-6748 Internet: www.ncwaterquallty.org State Employees' Credit Union September 19, 2012 Stormwater Application No. SW8 070727 If you need additional time to submit the information, please mail, email or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. Please reference the State assigned project number on all correspondence. Any original documents that need to be revised have been sent to the engineer or agent. All original documents must be returned or new originals must be provided. Copies are not acceptable. If you have any questions concerning this matter please feel free to call me at (910) 796-7215 or email me at steven.pusey@ncdenr.gov. Sincerely, Steve G. Pusey Environmental Engineer GDS/sgp: SAMMStormwaterTermits & Projects120071070727 HD12012 09 addinfo 070727 cc: Dale Hyatt, PE — McKim & Creed, Inc. Wilmington Regional Office Stormwater File PaoP '? of STORMWATER SUBMITTAL REQUIREMENTS INFILTRATION/EXFILTRATION SYSTEMS Basins and Trench Objective A. Collect all runoff from all BUA (proposed and/or existing and/or offsite) as the case may be, by any means including piping or swales, and direct it to the infitration system. B. Check the proposed basin/ trench design to make sure it meets or exceeds the minimum design criteria for design storm, volume and drawdown. II. What makes up a complete infiltration basin / trench application package? �A. Two sets of sealed, signed & dated layout & grading plans with appropriate details. ✓B. Completed application (SWU-101) with supplement(s), SW401-Infiltration Basin, SW 401- Infiltration Trench, SW 401-Level Spreader, and inspection.and maintenance agreements. Deed restriction document, if applicable. (subdivisions & projects with out parcels) Sealed, signed & dated calculations. ✓� A soils report containing information in regard to the soil type, boring locations, seasonal high water table elevation and expected infiltration rate. III. BIMS entry (for DWQ use only) Enter & track application acknowledged date, review date, add info requested/received dates, permit issue dates, and drainage area and stream/waterbody info. Best done after the add info letter is written and before sending permit up for signature. IV/ Shell documents (for DVVQ use only) Permit shells: s:\wqs\stormwater\shell\shighcominbasin S:\wqs\stormwater\shells\highcomintrench s:\wqs\stormwater\shells\highsubinbasin s:\wqs\stormwaterlshells\highsubintrench Calculations: s:\wqs\stormwater\excel spreadsheets\inbasin s:\wqs\stormwaterlexcel spreadsheets\intrench V. Review Procedure- look for consistency between the various elements of the package- application, plan and calculations. A. PPLICATION 1. Original signatures are required. Photocopied signatures cannot be accepted. VZ A completed infiltration basin or infiltration trench supplement, one for each proposed system. A signed, dated and notarized Inspection and Maintenance Agreement for each proposed system with an original signature. The elevations, areas and volumes reported on the supplement match up to the / numbers used in the calculations and shown on the plan details. ram. Built -upon areas are reported in square feet in Section 111.9. Receiving stream name and classification. Section 111.9 is filled in -cannot be left blank. One column must be filled in for each proposed infiltration basin or trench. If the applicant is a corporation, partnership or LLC, look it up on the Secretary of State Corporations Database. Make sure corporation is spelled correctly (capitalization and punctuation matter) and that the person signing the application is at least a vice- president in the corporation, a General Partner in the partnership, a member in a member -managed LLC, or the manager of a manager -managed LLC. Need documentation to support if the Articles of incorporation do not list the members or managers of the LLC. If an agent signs, then a letter of authorization is needed from the president, vice president, general partner, member or manager. For subdivided projects, a signed and notarized deed restriction statement must be provided. Soils report with the SHWT, Soil type and expected infiltration rate_ Page 7 of 12 Infiltration Basin & Trench, cont. B.�/ CALCULATIONS The basin or trench must draw down within 5 days. Spray irrigation is not acceptable as the sole means of drawdown. For sites with high infiltration rates, the maximum infiltration rate to use for the design is10 in/hr, per Vincent Lewis. 1 (D40'The design storm is 1.5" if the project is subject to Phase II or is sited within'/ mileof and draining to SA waters. Otherwise, use 1" design storm. For Phase II projects that are within 'h mile of and draining to SR waters, the difference in runoff from the predevelopment and post -development conditions for the 1 year 24 hour storm must be controlled and treated. Report the bottom surface area. Report the surface area at the overflow elevation. Show the calculation for the minimum required volume. Provide a table of elevations, areas, incremental volumes and accumulated volumes to demonstrate that the minimum required volume has been provided. Calculations are signed, sealed & dated. Report the Drainage Area and Built -upon area for each basin or trench. 11 The seasonal high watertable must be at least 24" below the proposed bottom elevation '- of the system. For Phase II projects, at least 12" of this must be in naturally occurring soils. All runoff in excess of the design storm must bypass to a vegetated filter prior to entering /0 the basin or trench. If the system is designed to store a larger design storm (generally 2- 3 times the minimum), the requirement for an offline bypass can be waived. Please contact the Division to determine what design storm is appropride for the project. ?c aQ"Srsn V, q&o) 4 SJ -P Vf�s- -G I S:1WQSISTORMWATERIFORMSICHECKLIST Page 8 of 12 Infiltration Basin & Trench, cont. C. PLANS - Plan sheets should be kept to a minimum. For small commercial single basin projects, the plan set could consist of only 2 or 3 sheets, layout, grading and details. For larger projects, show as much information as possible on as few sheets as possible, without ttering them up. I Development/Project Name Engineer name and firm. p, Legend t North Arrow r/5. Location Map with nearest intersection of two major roads shown. Major road is any 1, 2, or 3 digit NC, US or interstate highway. Scale- standard engineering scale, no off-the-wall stuff. Date Revision number and date, if applicable. r Original contours, proposed contours, spot elevations, finished floor elevations, pipe inverts, swale inverts, etc. _A-07 Existing drainage (piping, swales, ditches, ponds, etc.), including off -site. Include a map delineating the offsite drainage areas. Property/Project boundary lines, bearing & distances. Mean High Water Line or Normal High Water Line, if applicable. Drainage easement locations shown on the plans along with their width. Wetlands delineated, or a note on the plans that none exist. Provide a copy of the wetlands delineation map signed by the Corps of Engineers, or contact the appropriate field rep for the Corps to see if they can email a statement regarding the status of the ,delineation. Infiltration systems may not be located in wetlands. Details for the roads, parking, cul-de-sacs, including sidewalk width, radii, dimensions & �stopes. Apartment / Condo development- provide a typical building footprint with dimensions, nd note all concrete and wood deck areas. �I'�7 The drainage area for each basin or trench is clearly delineated and numbered to match up to the calculations and supplement. Drainage area delineation is best done as a separate plan sheet. A basin section detail showing bottom and storage elevations, 3:1 sidees�slo�ppe��s. The side slopes of an infiltration basin are not restricted to vegetation. They mayue hardened with rock, timber, concrete, decorative brick, etc. -,A trench section detail with the perforated pipe diameter, filter fabric wrapped around the pipe and around the trench, trench height and width, rock fill type. If using a pre-fab chamber structure, provide details of the chamber, including model #, length, width, chamber volume and number of chambers being used. �A bypass structure detail is provided showing a trash rack with s6" square openings, and the necessary bypass weir or pipe elevation. Several types of bypass structure designs are acceptable. imensions for each line and arc formed by the bottom contour of an infiltration basin. All runoff in excess of the design storm must pass through a vegetated filter prior to being discharged into the receiving stream. The filter must be 50' long for SA waters and _,30' long for non -SA waters. VII infiltration systems must be located at least 50' from the MHW line of surface waters. egetation is specified for basin slopes not being hardened. Weeping Love Grass is not suitable as a permanent vegetated cover for side slopes. , ""All roof drainage must be directed to the system. Show the roof drain collection piping on the plans. This is especially necessary for projects where the buildings back up the property lines where roof drainage may leave the site prior to going through the system. 27. Monitoring wells may be required on a case -by -case basis. Page 9 of 12 Nelson, Christine From: Dale Hyatt [DHyatt@mckimcreed.com] Sent: Tuesday, September 04, 2012 3:37 PM To: Nelson, Christine Subject: RE: SECU Mrytle Grove SW permit modification - completeness review Attachments: Stormwater Application Form.pdf; Infiltration Basin O&M.pdf Christine, Attached are the signed stormwater application form and 0&M manual. I will overnight these to you. If you do not receive them tomorrow please contact me. Thank you, Dale Hyatt, PE From: Nelson, Christine[mailto:christine.nelsoncancdenr gov] Sent: Wednesday, August 29, 2012 11:06 AM To: Dale Hyatt Subject: RE: SECU Mrytle Grove SW permit modification - completeness review Dale, Have you had any luck obtaining the new signature? Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. From: Nelson, Christine Sent: Wednesday, August 22, 2012 3:40 PM To: 'dhyatt@mckimcreed.com' Subject: SECU Mryde Grove SW permit modification - completeness review Dale, A completeness review has been conducted of the package submitted to modify the SW permit for the SECU at Myrtle Grove (SW8070727). The completeness review has found a few items need to be corrected: ? Section 111.1a of the application: The organization submitting the modification (as registered with the Secretary of State's website) should be listed in the first line. The vice president's name and title should be listed on the second line. ? Section IX and X of the application: The vice president signed the wrong section of the application. Section X should be completed. Please submit the corrected items as soon as possible in order for the Division to log in the modification. Thanks, Christine Christine Nelson Environmental Engineer State Stormwater Program NC Division of Water Quality 127 Cardinal Drive Ext. Wilmington, NC 28405 Phone: 910-796-7323 Nelson, Christine From: Nelson, Christine Sent: Wednesday, August 22, 2012 3:40 PM To: 'dhyatt@mckimcreed.com' Subject: SECU Mrytle Grove SW permit modification - completeness review Dale, A completeness review has been conducted of the package submitted to modify the SW permit for the SECU at Myrtle Grove (SW8070727). The completeness review has found a few items need to be corrected: • Section 111.1a of the application: The organization submitting the modification (as registered with the Secretary of State's website) should be listed in the first line. The vice president's name and title should be listed on the second line. • Section IX and X of the application: The vice president signed the wrong section of the application. Section X should be completed. Please submit the corrected items as soon as possible in order for the Division to log in the modification. Thanks, Christine Christine Nelson Environmental Engineer State Stormwater Program NC Division of Water Quality 127 Cardinal Drive Ext. Wilmington, NC 28405 Phone: 910-796-7323 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. DIVISION OF WATER QUALITY INFILTRATION SYSTEM INVESTIGATION Complete and email this form to Vincent.Lewis@ncmail.net. If there are more than 7 areas to be tested, attach a second sheet ¢ /' State Soil Scientist Confirmation Visit date/time: Project Name: SECU Myrtle Grove County: New Hanover Street Address: 141 Sanders Road, Myrtle Grove, NC Directions from the nearest intersection of two major roads: From the intersection of Sanders Road and Carolina Beach Road travel west alona Sanders Road for approximately 800 feet. Wet detention basin is on the east side of the undeveloped lot to the east of the existing SECU. >1 acre being disturbed? ❑YES ®NO CAMA Major required? DYES ®NO Consultant Name: Branch Smith, PE Phone: (910) 343-1048 Consultant Firm Name: McKim & Creed, Inc. Bore Number 1 2 3 4 5 8 7 1 a Existing Ground Elevation 39 38.5 b Proposed Bottom Elevation 33 33 c Difference a minus b 6 5.5 d Add 2 ft. Min. Bore Depth) 8 7.5 e Hardpan Depth? Approx. Elev. Of SHWT 31 31 Max. lowest bottom elev. 33 33 h Infiltration Rate OK? * I V: I' i Confirmation of SHWT * i f ' T, For projects requiring more than 5 hand borings, manpower or equipment to conduct the excavation must be provided by the consultant. *State Soil Scientist Use ONLY Comments 6r eti(tr An, 2A Required Attachments: 1. Legible vicinity map. 2. Complete Soils Report. 3. PDF formatted site plan with the boring locations to be tested. Site plans should be emailed or hand -delivered only. Illegible faxed maps will not be accepted. All proposed infiltration areas and existing, active utility lines located within the proposed basin4rench must be marked and flagged. !f these areas are not flagged, the Soils Scientist reserves the right to decline to do the investigation. if the proposed infiltration system will be located in an area of existing pavement and there is no open area nearby, equipment capable of breaking through the impervious layer must be provided. The soils investigation does not take the place of a soils report prepared by an appropriate professional. The Soils Scientist will only verify the soil conditions that are reported in the Soils Report, and make a determination as to the suitability of the site to meet the infiltration design requirements under NCAC 2H.1000, and assumes no liability should, the system fail. Lewis, Vincent From: Dale Hyatt [DHyatt@mckimcreed.com] Sent: Thursday, August 09, 2012 9:47 AM To: Lewis, Vincent Cc: Branch Smith Subject: SECU Myrtle Grove Infiltration Basin -141 Sanders Road Myrtle Grove, NC Affachments: SSW-inf-site-visit-request-DWQ-SPU[1].pdf; Vicinity Map.pdf; Soils Report.pdf; Site Plan with Boring Locations.pdf; S&EC Soils Evaluation.pdf Vincent, Attached are the infiltration system visit request form and the required attachments. I have also included a soils evaluation done by S&EC for the site. I have copied Branch Smith from our Wilmington office as he will be the one meeting you on site at 11:00 am Monday August 13t". To summarize our work, we are looking at converting/modifying the existing wet pond on site into an infiltration basin. Please let me know if you have any questions. Thank you, Dale Hyatt, PE, LEED AP I Project Engineer Tel 919.233.5261 x133 1730 Varsity Drive, Suite 500 1 Raleigh, NC 27606 DHvaft@mckimcreed.com I httn://www.mckimcreed.com Follow us on: YouTube I twitter I facebook I Unkedln To send me a file larger than 10MB please click here This e-mail and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this e-mail in error please notify the system manager. Please note that any views or opinions presented in this e-mail are solely those of the author and do not necessarily represent those of the company. Finally, the recipient should check this e-mail and any attachments for the presence of viruses. The company accepts no liability for any damage caused by any virus transmitted by this e-mail. 1 �' � w `�, � z �------- '�� M Soll & Environmental Consultants, PA 11010 Rzm RWp Road • ltaldA Nor.1h Cudin 27614 • AM (919) 846.5900 • Fac (919) 84&M www.8andMmm June 29, 2012 Job # 11893.Sl Obrien Atkins Attn: David Kaiser 5001 S. Miami Blvd. Durham, NC 27703 Re: Detailed soils evaluation adjacent to the existing wet detention basin of the Myrtle Grove State Employee's Credit Union, located off of Sanders Road, New Hanover County, NC. Dear Mr. Kaiser: Soil & Environmental Consultants, PA (S&EC) performed a detailed soil evaluation around the perimeter of the existing wet pond location on the site mentioned above. The purpose of this evaluation was to provide additional information to aid in the stormwater BMP design by providing applicable soil morphological and "hydraulic conductivity data. Soil borings were advanced to a depth of 8 to l 1 feat from the existing ground surface. The following is a brief report of the methods utilized in this evaluation and the results obtained. Soil/Site Evaluation Methodel The site evaluation was performed by advancing hand auger borings to a depth of 8 to 11 feet from the existing ground surface. Soil morphological conditions were described at each location using standard techniques outlined in the "Field Book for Describing and Sampling Soils" published by the Natural Resources Conservation Service (NRCS, 2002). A detailed soil profile description is included in Attachment 1. Soil/Site Conditions Field investigation revealed that the soils on site are most similar to the Kureb soil series. Kureb series soils are considered excessively drained and rapidly permeable. S&EC identified soil morphological features indicative of a seasonal high water table (SHWT) at a depth of 131" below top of ground (TOG). Based on the existing topography, this depth to SHWT corresponds to an approximate elevation of 31 feet above MSL. Under c—z t NC_Dtun reg., ,lion;, the bottom rf be proposed infiltration basin must be at least 2 feet above the Seasoril High Water Table (SHWT). Hvdranlie Conductivity Analysis: Three Saturated hydraulic conductivity (Ksat) mcasurements were conducted by the constant head well permeameter technique (also known as shallow well pump -in technique and bore hole permeameter method). This procedure is described in Methods of Soil Analysis, Part I., Chapter 29 — Hydraulic Conductivity of Saturated Soils: Field Methods, 29 — 3.2 Shallow Well Pump In Method, pp. 758-763 and in the Soil Science Society of America Journal, Vol. 53, no. 5, Sept. — Oct. 1989, "A Constant -head Permeameter for Measuring Saturated Hydraulic Conductivity of the Vadose Zone" and "Comparison of the Glover Solution with the Simultaneous — Equations Approach for Measuring Hydraulic Conductivity." In essence, a volume of water was applied and measured with time until a steady state of water flow was achieved. This volume/time with steady state was used to calculate the saturated hydraulic conductivity of the subsoil by the Glover equation. S&EC conducted three Ksat measurements around the perimeter of the existing wet pond. Ksat measurement #1 was conducted at a depth of 91 inches from top of ground while Ksat #2 and Ksat #3 were run at 95 inches and 72 inches from top of ground, respectively. Ksat data calculations/field data are also included in Attachment 3. Measured Ksat Values. Location I Testing Depth Soil Texture Ksat (InAhr) Ksat 1 91" Sandy loam 16.435 Ksat 2 95" Sandy loam 21.365 Ksat 3 72" Sand 22.859 a�ege= 2o.a2 Under current NC-DWQ regulations, soils underlying the infiltration basin must have a drainage rate of greater than 0.52 in/hr. Based on measurements collected, the tested underlying soil horizons have an average Ksat of 20.22 in/hr. Based on this data, S&EC believes that the soil horizons that underlie the proposed infiltration basin would have adequate capacity to assimilate storm water at a rate of at least 0.52 in/hr. Soil & Environmental Consultants, PA is pleased to be of service in this matter and we look forward to assisting in the successful completion of the project. If requested, S&EC can meet on -site with NC-DWQ to discuss our findings and recommendations. Please feel free to call with any questions or comments. Sincerely, Soil & Environmental Consultants, P, Ricky Pontello NC Licensed Soil Scientist #1232 112. Boring LoCatFOn 1 Horizon 1 Depth (in) 0-8 Horizon Designation Matrix Color 10YR 4/6 Mottle Color Texture sand Structure single grain Moist nsis rice loose Horizon 2 in 5 n-23 in Horizon Designation Matrix Color 7.5YR 6/6 Mottle Color Texture sand Structure single grain Moist ns s rice loose Horizon 3 Depth23 in - W in Horizon Designation Matrix Color 7.5YR 7/6 Mottle Color Texture sand Structure single grgin 16st Consistence loose Horizon 4 De m Grin - 84 in Horizon Designation Matrix Color 10YR fiffi Mottle for Texture loamy sand Structure granular o s consistence very frlable Horizon 5 De in - -- 84-118 - - Horizon Lion Matrix Color__ Mottle Color Texture San loair, Structure r ois s erica y asular : ' rig e --118-131 orizon t in Horizon Des nation 10YR 714 -�_ _-=-, - ---- Matrix Color Mottle Color Texture sand Structure granular Moist is loose Horizon 7 e t , m 131-144 Horizon Designation Matrix Color 5YR 5/8 Mottle Color 10YR 7/1 Ti eAjre sand Structure granulat Moist ons s ence loose Attachment 1. Soil Profile Description Pro)acs dame: Myrtle Grove SEW Job Number: 11893.S1 Date: 06/26/12 Conducted By: RP Depth W seasonal high water table 131" from TOG WT elevation 311 Aviqt:wmEq r z INFORMATION Date 6126/2012 Measurement Conducted By RP Job Name MYRTLE GROVE SEW Job Number 11893.S1 Weather Condition' Clear Temperature 90 Location KSAT #1 Hcnzon 'rap — ---- - __ Source of Water Value Units Radius of Hole 3.5 cm Reg of How 231.14, Initta] Depth of Water in Hole (HJ Final Depth of Water in Hole (H) 7.662 crr.._,.r 7.621rm 2.1 t i I 0.4188 _�_.... .v Ratio H/r �. a ime 11:13 ING Of I NG..__.irs UU .._a , �' 2 A factor in t= uatior 1z, of Manual 0.00240945 Inches Hole Depth. 91 H(lnitlao: 3 H(flnaQ: 3 AVERAGES NJW 246.718 41.74 16.435 J INFORMATION Date V2612012 Measurement Conducted By iRP- Job Nowne MYRTLE GROVE SECU Job Number 1693.51 Weather Condition Gear Temperature Locabon so KSAT#2 HorzDn Source of Water Ta e Valu ft�Units Radius of Hole 1 3.5 cm i of Hole 241.3 DaAh of Water m Hole U 7 62 cm V;WI Depth of Water tn Hole (H) 7-62 cm we 2.1771 0.4188 Sailummon Time R Re"nows Used at SQ;:lGete 2 Vl� a lasow M ;rv—, ,,.I 0.00242945_ ;ciock -- r —,Me Wafer Levei lReadmY Time Interva Change in Water Level, CM Minute lcm -18 143 1139 105 1.00 ,Ah, 1140 33 361 -IL .3.2. c) L 3-OL A i.00i Inches Hole Depth; 95 H(kidso: 3 fl N(niml); 73 AVERAGES 0 S 3200.79 54.27 21.365 INFORMATION Date a/2012 Measurement Conducted B RP Job Name MYRTLE GROVE SECU Job Number 11893.S1 Weather Condition Clear Temperature 90 Location #3 Horizon �ojrce of Water rap Vallue Units Radius of Hole 3.5 cm Pepth of Hale 182.88 lal Dspth of 'dater in Hole `H 7.62 ;rn Final Rgth cif 1Alater !rl Hole , �. 7.62 cw Rat10_ H/r -.�_ ... . Start ait�t ujilt n Time 2.1771 y 0.4188 11:65 o. of Reservoirs Used at ail -State 2 A factor in Equation {2) of Manual •10.00240945 Gluck lime W atei Level f ReadingWater GM Time into rva Change in _Level [Minuta�crr4 —_ i i 55 15-3 1157 1116 1.001 3.7 11,58 1159 1200 4211 L P� �T 1.i4 4 i.er_=-k.1 r.,y7iid1F }ti�11,�1VT.' Inches Hole Depth: 72 H(Initiel): 3 H(tina�: 3 AVERAGES f!1 r iflrjlf n 343.22 58.06 22.850 USDA United States A product of the National Custom �01� Resource Department of Cooperative Soil Survey, Agriculture a joint effort of the United Report for FC States Department of Agriculture and other New Hanover, Hanover, Federal agencies, State Natural Resources agencies including the Agricultural Experiment County, N o rth Conservation Stations, and local Service participants Carolina SECU Myrtle Grove August 6, 2012 Contents Preface ............................ ......... ......... ........................,............. ...... 2 SoilMap ................................ ....................... ...,..................................... ..................5 SoilMap ..................................................... .................................... ....... ............... .S Legend...............................................................................................................7 MapUnit Legend...................................................................................:...............8 MapUnit Descriptions.................................................. ....... ...... ... ........ .8 New Hanover County, North Carolina.............................................................10 Kr—Kureb sand, 1 to 8 percent slopes........................................................1 Q Ly—Lynn Haven fine sand.. »............ ................................ 11 4 Soil Mafia The soil map section includes the soil map for the defined area of interest, a list of soil map units on the map and extent of each map unit, and cartographic symbols displayed on the map. Also presented are various metadata about data used to produce the map, and a description of each soil map unit. 5 .BS.M LL N � Wo oco co As ,£S .0 Z-< „4G ,4S .0 z N. z IL a� 0 Z W W J IL c o. g T l9 O I g f T c o a' E o °� r om E 1.00 E p ��7 C n �O °0 ir Z N 3 3 I C .a W O Z C N 4= w N 0 ..W W E U .O Z U C {O U73 L o. � C � p�� o•'�-��� o m w w o c o ��z+g.0 maN c� me n y�E a E j o I c a>i o w t � a _• a� w E CL � m G� d� m � > > � J to2 Laa d j � a w � 9y cO . yT G W Olw p C L Z= E T C y w Im N O•— W O r 0 y W T M � l0 E p G.D 67 Z e �p7 S4 EE g a su)�; o w }Ng'a' �T OW-0c N O C ID 1-2 W r 0= LO N ZE- w CL wn 71 ayi IE E 9 mNa� wEa» W+ao' at v1 0 w — U) " a m °DE 9810 i=- m S a N a E rc N Y .0 o a RX e C9 ti7 O U in QIx 3 :3_ LIE, fr +1 � i2 , t . A � LL � p a a° ►�- g o � 1° E 03 m ggo j m CL c w 5_ _a p O C a d 6 O a Na'• C O O •g f� fn T m Lo 4 6 « g m-OMO S a8 ci U c� .3 a z° 0 0 u7 v"i u°7 wIL ai Custom Soil Resource Report Map Unit Legend Map Unit Descriptions The map units delineated on the detailed soil maps in a soil survey represent the soils or miscellaneous areas in the survey area. The map unit descriptions, along with the maps, can be used to determine the composition and properties of a unit. A map unit delineation on a soil map represents an area dominated by one or more major kinds of soil or miscellaneous areas. A map unit is identified and named according to the taxonomic classification of the dominant soils. Within a taxonomic class there are precisely defined limits for the properties of the soils. On the landscape, however, the soils are natural phenomena, and they have the characteristic variability of all natural phenomena. Thus, the range of some observed properties may extend beyond the limits defined for a taxonomic class. Areas of soils of a single taxonomic class rarely, if ever, can be mapped without including areas of other taxonomic classes. Consequently, every map unit is made up of the soils or miscellaneous areas for which it is named and some minor components that belong to taxonomic classes other than those of the major soils. Most minor soils have properties similar to those of the dominant soil or soils in the map unit, and thus they do not affect use and management. These are called noncontrasting, or similar, components. They may or may not be mentioned in a particular map unit description. Other minor components, however, have properties and behavioral characteristics divergent enough to affect use or to require different management. These are called contrasting, or dissimilar, components. They generally are in small areas and could not be mapped separately because of the scale used. Some small areas of strongly contrasting soils or miscellaneous areas are identified by a special symbol on the maps. If included in the database for a given area, the contrasting minor components are identified in the map unit descriptions along with some characteristics of each. A few areas of minor components may not have been observed, and consequently they are not mentioned in the descriptions, especially where the pattern was so complex that it was impractical to make enough observations to identify all the soils and miscellaneous areas on the landscape. The presence of minor components in a map unit in noway diminishes the usefulness or accuracy of the data. The objective of mapping is not to delineate pure taxonomic classes but rather to separate the landscape into landforms or landform segments that have similar use and management requirements. The delineation of such segments on the map provides sufficient information for the development of resource plans. If intensive use of small areas is planned, however, onsite Investigation is needed to define and locate the soils and miscellaneous areas. Custom Soil Resource Report An identifying symbol precedes the map unit name in the map unit descriptions. Each description includes general facts about the unit and gives important soil properties and qualities. Sails that have profiles that are almost alike make up a soil series. Except for differences in texture of the surface layer, all the soils of a series have major horizons that are similar in composition, thickness, and arrangement. Soils of one series can differ.in texture of the surface layer, slope, stoniness, salinity, degree of erosion, and other characteristics that affect their use. On the basis of such differences, a soil series is divided into soil phases. Most of the areas shown on the detailed soil maps are phases of soil series. The name of a soil phase commonly indicates a feature that affects use or management. For example, Alpha silt loam, 0 to 2 percent slopes, is a phase of the Alpha series. Some map units are made up of two or more major soils or miscellaneous areas. These map units are complexes, associations, or undifferentiated groups. A complex consists of two or more soils or miscellaneous areas in such an intricate pattern or in such small areas that they cannot be shown separately on the maps. The pattern and proportion of the soils or miscellaneous areas are somewhat similar in all areas. Alpha -Beta complex, 0 to 6 percent slopes, is an example. An association is made up of two or more geographically associated soils or miscellaneous areas that are shown as one unit on the maps. Because of present or anticipated uses of the map units in the survey area, it was not considered practical or necessary to map the soils or miscellaneous areas separately. The pattern and relative proportion of the soils or miscellaneous areas are somewhat similar. Alpha - Beta association, 0 to 2 percent slopes, is an example. An undifferentiated group is made up of two or more soils or miscellaneous areas that could be mapped individually but are mapped as one unit because similar interpretations can be made for use and management. The pattern and proportion of the soils or miscellaneous areas in a mapped area are not uniform. An area can be made up of only one of the major soils or miscellaneous areas, or it can be made up of all of them. Alpha and Beta soils, 0 to 2 percent slopes, is an example. Some surveys Include miscellaneous areas. Such areas have little or no soil material and support little or no vegetation. Rock outcrop is an example. Custom Soil Resource Report New Hanover County, North Carolina Kr--Kureb sand, i to 8 percent slopes Map Unit Setting Elevation: 0 to 20 feet Mean annual precipitation: 42 to 58 inches Mean annual air temperature: 61 to 64 degrees F Frost -free period: 190 to 270 days Map Unit Composition Kureb and similar soils. 85 percent Minor components: 5 percent Description of Kureb Setting Landfonn. Rims on caroling bays, ridges on marine terraces Landform position (two-dimensional): Summit, shoulder Landform position (three-dimensional): Crest Down -slope shape: Convex Across -slope shape: Convex Parent material. Eolian sands and/or sandy fluviomarine deposits Properties and qualities Slope: 0 to 6 percent Depth to restrictive feature: More than 80 inches Drainage class: Excessively drained Capacity of the most limiting layer to transmit water (Ksat): High to very high (5.95 to 19.98 in/hr) Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Available water capacity. Very low (about 1.8 inches) Interpretive groups Land capability (nonirrigated): 7s Typical profile 0 to 3 inches: Sand 3 to 26 inches: Sand 26 to 89 inches: Sand Minor Components Leon Percent of map unit. 5 percent Landform. Flats on marine terraces Down -slope shape: Linear Across -slope shape: Concave 10 Custom Soil Resource Report Ly—Lynn Haven fine sand Map Unit Setting Elevation: 20 to 160 feet Mean annual precipitation: 40 to 55 inches Mean annual air temperature: 59 to 70 degrees F Frost --free period, 200 to 280 days Map Unit Composition Lynn haven, undrained, and similar soils. 85 percent Description of Lynn Haven, Undrained Setting Lancform: Flats on marine terraces Down -slope shape: Linear Across -slope shape: Linear Parent material., Sandy fluviomarine deposits and/or eolian sands Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Poorly drained Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 5.95 in/hr) Depth to water table: About 0 to 6 inches Frequency of flooding. None Frequency of ponding: None Maximum salinity., Nonsaline (0.0 to 2.0 mmhos/cm) Available water capacity: Moderate (about 8.3 inchesl Interpretive groups Land capability (nonirrigated): 4w Typical profile 0 to 9 inches: Sand 9 to 12 inches: Fine sand 12 to 80 inches: Sand 11