Loading...
HomeMy WebLinkAboutSW4211201_Design Calculations (Culvert)_20220113Date: 10/8/2021 Project Number: 21-0577 PIPE DATA SHEET Sheet 1 of I.D. No.: County: Forsyth Designed By: JFO Reviewed By: HSR GP Elev.: 865.10 ft Plan Summary Data Shoulder Drainage Area: 3.6 Alignment: Grove Elev.: 866.00 ft Design Freq.: 25 Station: 0+34 Design Disch.: 11.29 Skew: 0 Outlet Ground Elev. Design H.W. Elev.: 864.80 Size/Type Pipe: Type Entrance: Groove -End Inlet Ground Elev. ft H.W. H ft Q100 Disch.: Q100 Elev.: 12.47 865.10 Direction of Flow: RT to LT LSo T.W. Overtopping Freq.: >100 YR Hydrologic Method: Rational Inlet So= 3.3% Overtopping Disch.: 9.90 H.W. Control Elevation: 866 Invert Elev.: 862.5 ft L= 46.0 ft Outlet Inv. Elev. 861.0 ft Overtopping Elev.: 865.4 H.W. Control Feature: SR Shldr. TW Channel Specs.: Slope: 0.033 Lt. Side Slope= 3 RCP=.012, CMP=.024 n= 0.012 Base Width= 1.5 n= 0.035 Rt. Side Slope= 3 BARRELS FREQ TW Q Nat. H.W. Allow. H.W. Inlet Control Outlet Control HW ELEV. Vo* Remarks SIZE No. Of HW/D HW (ft) Ke d, (d,+D)/2 ho H LSO HW in Pipes YR ft ft^3/s ft ft ft/ft ft ft ft ft ft ft ft ft/s 18 1 10 1.5 10.29 1.33 2.00 1.30 1.40 1.50 0.899 1.50 0.90 864.50 INLET CONTROL 18 1 25 1.6 11.29 1.53 2.30 1.37 1.44 1.60 1.082 1.50 1.18 864.80 INLET CONTROL 18 1 50 1.6 11.93 1.60 2.40 1.42 1.46 1.60 1.208 1.50 1.31 864.90 INLET CONTROL 18 1 100 1.7 12.47 1.73 1 2.60 1.46 1 1.48 1 1.70 1.321 1.50 1.52 865.10 INLET CONTROL Notes & Calculations Tc = 10 min Overtopping Elevation is lowest point on new road where water will overtop before reaching SR shoulder SR: "State Road" *Vo is partial flow velocity. SUMMARY AND RECOMMENDATIONS: Install 1 @ 18" R.C. Pipe Class III or 18" HDPE Pipe (Double -walled, smooth bore) print date: 10/8/2021 Date: 10/8/2021 Project Number: 21-0577 PIPE DATA SHEET Sheet 2 of I.D. No.: County: Forsyth Designed By: JFO Reviewed By: HSR GP Elev.: 869.50 ft Plan Summary Data Shoulder Drainage Area: 1.21 Alignment: Grove Elev.: 869.00 ft Design Freq.: 25 Station: 6+93 Design Disch.: 4.16 Skew: 0 Outlet Ground Elev. Design H.W. Elev.: 865.68 Size/Type Pipe: Type Entrance: Groove -End Inlet Ground Elev. ft H.W. H 864.6 ft Q100 Disch.: Q100 Elev.: 4.60 865.76 Direction of Flow: LT to RT LSo T.W. Overtopping Freq.: >100 YR Hydrologic Method: Rational Inlet So= 1.0% Overtopping Disch.: 9.90 H.W. Control Elevation: 869 Invert Elev.: 864.5 ft L= 50.0 ft Outlet Inv. Elev. 864.0 ft Overtopping Elev.: 865.4 H.W. Control Feature: Shldr. at LP TW Channel Specs.: Slope: 0.033 Lt. Side Slope= 3 RCP=.012, CMP=.024 n= 0.012 Base Width= 1.5 n= 0.035 Rt. Side Slope= 3 BARRELS FREQ TW Q Nat. H.W. Allow. H.W. Inlet Control Outlet Control HW ELEV. Vo* Remarks SIZE No. Of HW/D HW (ft) Ke d, (d,+D)/2 ho H LSO HW in Pipes YR ft ft^3/s ft ft ft/ft ft ft ft ft ft ft ft ft/s 15 1 10 0.8 3.79 0.88 1.10 0.79 1.02 1.02 0.294 0.50 0.81 865.60 INLET CONTROL 15 1 25 0.8 4.16 0.94 1.18 0.83 1.04 1.04 0.354 0.50 0.89 865.68 INLET CONTROL 15 1 50 0.8 4.40 0.98 1.23 0.86 1.05 1.05 0.395 0.50 0.95 865.73 INLET CONTROL 15 1 100 0.9 4.60 1.01 1 1.26 0.88 1 1.06 1 1.06 0.432 0.50 1.00 865.76 INLET CONTROL Notes & Calculations Tc = 10 min Overtopping Elevation is low point at sag vertical curve; elevation = 869.47 LP: "Low Point" *Vo is partial flow velocity. SUMMARY AND RECOMMENDATIONS: Install 1 @ 15" R.C. Pipe Class III or 15" HDPE Pipe (Double -walled, smooth bore) print date: 11/22/2021