Loading...
HomeMy WebLinkAboutSW8070926_HISTORICAL FILE_20110628STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 (YA09-LU DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE r 1 p�D 2_8 YYYYMMDD 7*�A NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director June 28, 2011 Cad Baker, Deputy Public Work Officer MCB Camp Lejeune Building 1005 Michael Road MCB Camp Lejeune, NC 28547-2521 Subject: State Stormwater Management Permit No. SW8 070926 MOD Wounded Warrior Hope and Care Center High Density Commercial Wet Detention Pond Project Onslow County Dear Mr. Baker: Dee Freeman Secretary The Wilmington Regional Office received a complete Stormwater Management Permit Application for Wounded Warrior Hope and Care Center on June 21, 2011. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000 and Session Law 2008-211. We are forwarding Permit No. SW8 070926 MOD dated June 28, 2011, for the construction, operation and maintenance of the BMP's and built -upon areas associated with the subject project. This permit shall be effective from the date of issuance until November 16, 2017, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing by fling a petition with the Office of Administrative Hearings (01 The petition must conform to Chapter 150B of the North Carolina General Statutes, and must be filed with the OAH within thirty (30) days of receipt of this permit. A petition is considered filed when it is received in the Office of Administrative Hearings during normal office hours. The OAH accepts filings Monday through Friday between the hours of 8:00 a.m. and 5:00 p.m., except for official state holidays. The petition may be filed by facsimile (fax) or electronic mail by an attached file (with restrictions) - provided the signed original, one (1) copy and a filing fee (if a filing fee is required by NCGS §150B-23.2) is received in the OAH within seven (7) business days following the faxed or electronic transmission. Unless such demands are made this permit shall be final and binding. You should contact the OAH with all questions regarding the filing fee and/or the details of the filing process. The mailing address, telephone and fax numbers for the Office of Administrative Hearings are: 6714 Mail Service Center, Raleigh, NC 27699-6714. Telephone 919-733-2698. FAX 919-733-3378. If you have any questions, or need additional information concerning this matter, please contact Chris Baker, at (910) 796-7215. Sinc Ely, In I for Colleen Sullins, Director Division of Water Quality GDS/csb: S:=SIStormwaterlPermits & Projects120111070926 HD12011 06 permit 070926 cc: Allan Barri JR., P. E., C. Allan Bamforth, Jr., Engineer -Surveyor, LTD. Onslow County Building Inspections Wilmington Regional Office Stormwater File Wilmington Regional Office One 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 w O-...i,�.0j1na Phone: 910-796.72151 FAX: 910-350-2004 1 Customer service: 1.877-623-6748 1 orffi Caroll� Internet: w .noaaterquality.org LL ar State Stormwater Management Systems Permit No. SW8 070926 MOD STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Carl Baker, Deputy Public Works Officer and USMCB Camp Lejeune USMCB Camp Lejeune Wounded Warrior Barracks Site Brewster Blvd, Jacksonville, USMCB Camp Lejeune, Onslow County FOR THE construction, operation and maintenance of four (4) wet detention ponds and one (1) infiltration basin in compliance with the provisions of 15A NCAC 2H .1000 and Session Law 2008-211 (hereafter collectively referred to as the "stormwater rules') the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until November 16, 2017, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described in Sections 1.8 and 1.9 on page 3 of this permit. The stormwater control has been designed to handle the runoff from 391,135 square feet of impervious area. 3. The tract will be limited to the amount of built -upon area indicated in Sections 1.8 and 1.9 on page 3 of this permit, and per approved plans. 4. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. 5. The runoff from all built -upon area within the permitted drainage area of this project must be directed into the permitted stormwater control system. 6. Wet ponds #1, 2 and the infiltration basin must be operated with a 30' vegetated filter, designed to pass the peak flow from the 10 year storm in a diffuse and non -erosive manner. LPage 2 of 8 State Stormwater Management Systems Permit No. SW8 070926 MOD The project shall provide a 50' wide vegetated buffer adjacent impounded structures, streams, rivers, and tidal waters in Drainage Area Number 3 & 4, which is subject to 15A 02H .1000 and SL2008-211, effective October 1, 2008. 8. The following design criteria have been provided in the wet detention ponds and must be maintained at design condition: Pond #1 DA #1 Pond #2 DA #2 Pond #3 DA #4 Pond #4 DA #5 a. Drainage Area, acres: Onsite, ft2: Offsite ft2 9.3 405,846 None 6.03 262,615 None 10.41 453,394 None 2.84 123,647 None b. Total Impervious Surfaces, ft: Onsite, ft2: Offsite, ft2 94,955 94,955 None 125,145 125,145 None 137,467 137,467 None 27,400 27,400 None C. Design Storm, inches: 1.5 1 1.5 1.5 1.5 d. Average Pond Design Depth, feet: 3 3 3.5 3 e. TSS removal efficiency: 85 85 90 90 f. Permanent Pool Elevation, FMSL: 7 14 14.5 13.5 9. Permanent Pool Surface Area, ft: 19,323 18,345 15,208 6,075 h. Permitted Storage Volume, ft: 21,210 20,318 20,652 4,286 i. Temporary Storage Elevation, FMSL: 8 14 15.7 14.1 Pre-dev. 1 r-24 hr. discharge rate, cfs: "" 5.43 1.32 k. Controlling Orifice, in: 2.5 2.5 2.5 1 I. Orifice flowrate, cfs: "" "' 0.09 0.70 m. Permitted ForebaV Volume, ft: 12,967 15,872 9,429 3,484 n. Fountain Horsepower 1/4 1/4 114 N/A o. Receiving Stream/River Basin: Northeast Creek / White Oak p. Stream Index Number: 19-16- 3.5 Classification of Water Body: "SC;HWQ,NSW" At the time of permitting, November 16, 2007, this criteria was not a requirement for ponds #1 & #2 9. The following design criteria have been permitted for the infiltration basin and must be provided and maintained at design condition: a. Drainage Area, acres: Onsite, ft2: Offsite, ft2: b. Total Impervious Surfaces, ft2: Onsite, ft2: Onsite, ft2: C. Design Storm, inches: d. Basin Depth, feet: e. Bottom Elevation, FMSL: f. Bottom Surface Area, ft2: g. Bypass Weir Elevation, FMSL: h. Permitted Storage Volume, ft3: i. Predevelopment 1 yr 24 hr peak flow, cfs: j. Post -development 1 yr 24 hr peak flow, cfs: k. Type of Soil: I. Expected Infiltration Rate, in/hr: M. Seasonal High Water Table, FMSL: n. Time to Draw Down, hours: o. Receiving Stream/River Basin: P. Stream Index Number: q. Classification of Water Body: Infiltration Basin - DA #3 0.31 13,529 0 6,168 6,168 0 1.5" 1 14.0 3,500 15.0 3,878 0.28 0.06 Baymeade 0.80 11.50 16.6 Northeast Creek / White Oak 19-16-(3.5) "SC;HWQ,NSW" Page 3 of 8 State Stormwater Management Systems Permit No. SW8 070926 MOD II. SCHEDULE OF COMPLIANCE The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. The permittee shall at all time provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and re -vegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device, flow spreader, catch basins and piping. g. Access to the outlet structure must be available at all times. h. Maintain level spreaders in accordance with approved plans and specifications. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. Decorative spray fountains will be allowed in the stormwater treatment system, subject to the following criteria: a. The fountain must draw its water from less than 2' below the permanent pool surface. b. Separated units, where the nozzle, pump and intake are connected by tubing, may be used only if they draw water from the surface in the deepest part of the pond. c. The falling water from the fountain must be centered in the pond, away from the shoreline. d. The maximum horsepower for a fountain in these three ponds is 1 /4 horsepower. 6. The facilities shall be constructed as shown on the approved plans. This permit shall become void unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this. permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. Access to the stormwater facilities shall be maintained via appropriate easements at all times. 10. The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction. Page 4 of 8 State Stormwater Management Systems Permit No. SW8 070926 MOD 11. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc. b. Project name change. C. Transfer of ownership of any part of the permitted property. d. Redesign or addition to the approved amount of built -upon area or to the drainage area. e. Further subdivision, acquisition, lease or sale of all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 12. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 13. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. III. GENERAL CONDITIONS This permit is not transferable except after notice to and approval by the Director. In the event of a change of ownership, or a name change, the permittee must submit a formal permit transfer request to the Division of Water Quality, accompanied by a completed name/ownership change form, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. The permit issued shall continue in force and effect until revoked or terminated. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. Page 5 of 8 State Stormwater Management Systems Permit No. SW8 070926 MOD Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 8. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 9. The permittee shall notify the Division any name, ownership or mailing address changes within 30 days. 10. The permittee shall submit a permit renewal application at least 180 days prior to the expiration date of this permit. The renewal request must include the appropriate documentation and the processing fee. Permit issued this the 28th day of June, 2011. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION �& �� for Colee . Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Page 6 of 8 State Stormwater Management Systems Permit No. SW8 070926 MOD MCB Camp Lejeune Wounded Warrior Barracks Site Stormwater Permit No. SW8 070926 MOD Onslow County Designer's Certification 1, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/ weekly/ full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specification: Signature Registration Number Date SEAL Page 7 of 8 State Stormwater Management Systems Permit No. SW8 070926 MOD Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 8. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 9. The permittee shall notify the Division any name, ownership or mailing address changes within 30 days. 10. The permittee shall submit a permit renewal application at least 180 days prior to the expiration date of this permit. The renewal request must include the appropriate documentation and the processing fee. Permit issued this the 28th day of June, 2011, NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Qx'Vc-�-pC�S� for Coleenfl. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Page 6 of 8 DINQ USE ONLY D to Received Fee Paid Permit Number p�pplica le Ru es: ❑ Coastal SW -1995 ❑ Coastal SW.- 2008 ❑ Ph LI - Post Construction (.elect all that apply) ❑ Non -Coastal SW- I IQIN/ORIN Waters ❑ Universal Stormcvater Management Plan ❑ Other WQ M rot Plan: State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original 1. GENERAL INFORMATION I Project Name (subdivision, facility, or establishmentname -should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): Proicct110084 Wounded Warrior Trailer Site Prep 2. Location of Project (street address): Hospital Corps Road _ City:MCBCamp Lejerme County:Onslow Zip:28547 3. Directions to project (from nearest major intersection): From Brewster Blvd, rioht on Hospital Corps Road.Approximately 1200' make a left onto unnamed road.Projec site is on left Southeast of BEQ 4. lititude34° 43' 18.41" N Longitude:770 21' 56.50" W of the main entrance to the project. it. PERMIT INFORMATION: 1. a .Specify whether project is (check one): ❑New ®Modification b.lfthis application is being submitted as the result of a modification to an existing permit, list the existing permit numberSW8 070926 , its issue date (if known)Aprtl 7, 2009 , and the status of construction: []Not Started ®Partially Completed* ❑ Completed* *provide a designer's certification 2. Specify the type of project (check one): ❑Low Density ®High Density ❑Drains to an Offsite Stormwater System ❑Other 3. If This application is being submitted as the result of a previously returned application or a letter from DWQ requesting a state stormwater management permit application, list the stormwater project number, if assigned, and the previous name of the project, if different than currently proposed, 4. a- Additional Project Requirements (check applicable blanks; information on required state permits can be ob'ained by contacting the Customer Service Center at 1-877-623-6748): ❑LAMA Major ®Sedimentation/Erosion Control: 2.84 ac of Disturbed Area ❑UPDI-S Industrial Stormwater 0404/401 Permit: Proposed Impacts b- If my of these permits have already been acquired please provide the Project Name, Project/Permit Number, issre date and the type of each permit: Fon1-h SP' V-101 Version 07Jun2010 JUN l 3 2011 Page 1 of 6 CIL CONTACT INFORMATION L.a,Print Applicant / Signing Of name and title (specifically the developer, property owner, lessee, designated government official, individual, etc. who owns the projecl): Applicant/Organization:Conunanding Officer Marine Corps Base Camp Lejeune Signing Official & Title:Nlr. Carl H. Baker, Jr., P.E., Deputy Publiic Works Director b.Contact information for person listed in item la above: Street Address:1005 Michael Road City:MCB Camp Lejeune State:NC Zip28547 Mailing Address (if applicable):1005 Michael Road City:CB Camp Lejeune State:NC Zip28547 Phone: (910 ) 451-2213 Email:carl.h.baker@usmcmil Fax: (910 ) 451-2927 Please check the appropriate box. The applicant listed above is: ®The property owner (Skip to Contact Information, item 3a) ❑ Lessee* (Attach a copy of the lease agreement and complete Contact Information, item 2a and 2b below) ❑ Purchaser* (Attach a cop}' of the pending sales agreement and complete Contact Information, item 2a and 2b below) ❑ beveloper* (Complete Contact Information, item 2a and 2b below.) 2. a. Print Property Owner's name and title below, if you are the lessee, purchaser or developer. (This is the person who owns the property that the project is located on): Property Owner/Organization: Signing Official & Title: b. Contact information for person listed in item 2a above: Street Address: City: failing Address (if applicable): City: Phone: ( ) Email: State: Zip: State: Fax: 3. a. (Dptional) Print the name and title of another contact such as the project's construction supervisor or other parson who can answer questions about the project: Other Contact Person/Organization:Mr. David Towler S!gning Official & Title:Mr. Carl H. Baker Jr.,P.E. Depute' Publiic Works Director b.Cnntact information for person listed in item 3a above: [Mailing Address:Public Works Division Building 1005 Civil Design Branch Ghy:MCB Camp Lejeune State:NC Zip:28547 Phone: (910 ) 451-3238 ext. 3284 Pax: ( ) Enail:ciavid.towler@usmc.mil 4. Local jurisdiction for building permits: N/A - Federal Property Point of Contact: Phone #: Form tWU-101 Version 07Jun2010 Paae 2 of 6 IV. PROJECT INFORMATION 1. In the space provided below, briefly summarize how the stormwater runoff will be treated. Stormwater will be collected in grassed swales and an inlet and piping system and drain to a wet detention 2. a. If claiming vested rights, identify the supporting documents provided and the date they were approved: ❑ Approval of a Site Specific Development Plan or PUD Approval Date: ❑ Valid Building Permit Issued Date: ❑ Other: Date: b.If claiming vested rights, identify the regulation(s) the project has been designed in accordance with: ® Coastal SW -1995 ❑ Ph II - Post Construction 3. Stormwater runoff from this project drains to the White Oak River basin. 4. Total Property Area: 2.84 acres 5. Total Coastal Wetlands Area: 0 acres 6. Total Surface Water Area: 0 acres 7. Total Property Area (4) - Total Coastal Wetlands Area (5) - Total Surface Water Area (6) = Total Project Area+:2.84 acres Total project area shall be calculated to exclude the following the normal pool of imppo�u�nded structures, the area between the banks of streams and rivers, the area below the Normal High Water (NHW) line or Mean High Water (MHW) line, and coastal wetlands landward from the NHW (or MHM line. The resultant project area :s used to calculate overall percent built upon area (B UA). Non -coastal wetlands landward of the NHW (or MHW) line may be included in the total project area. 8. Project percent of impervious area: (Total Impervious Area / Total Project Area) X 100 = 32 9 9. How many drainage areas does the project have?5 (For high density, count 1 for each proposed engineered stormwater BMP. For low density and other projects, use 1 for the whole property area) 10. Complete the following information for each drainage area identified in Project Information item 9. If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. Basin Informahon =' Drama 'e7Area 1 : iDiaiva' e Area 2 Draiiia 'e AreaB: , Draina e Area'4'. Receiving Stream Name Northeast Creek Northeast Creek Northeast Creek Northeast Creek Stream Class * SC;HQW;NSW SC;HQW;NSW SC;HQW;NSW SC;HQW;NSW Stream Index Number * 19-16-(3.5) 19-16-(3.5) 19-16-(3.5) 19-16-(3.5) Total Drainage Area (so 405,846 262,615 13,529 453,394 On -site Drainage Area (sf) 405,846 262,615 13,529 453,394 Off -site Drainage Area (so 0 , 0 0 0 Proposed impervious Area** (so 94,955 125,145 6,168 137,467 % Impervious Area** total 23.4% 47.7% 45.6% 30.3% 'Im -ervioi`is Surface Area Draina e Area 1 DrainaizeArea2. Drama e Area 3 Drain_ a' e'Area,4 On -site Buildings/Lots (so 10,827 31,799 0 43,565 On -site Streets (so 54,729 5,076 4,374 15,285 On -site Parking (so 10,429 84,942 0 61,139 On -site Sidewalks (so 18,907' 3,269 0 15,870 Other on -site (so N/A N/A 1,794 1,608 Future (so 0 1 0 1 0 0 Off -site (so 0 0 0 0 Existing BUA*** (so 0 0 0 0 Total (sf): 94,955 125,145 6,168 137,467 Stream Class and Index Number can be determined at: Impervious area is defined as the built upon area including, but not limited to, buildings, roads, sidewalks, gravel areas, etc. Form SWU-101 Version 07Jun2010 Page 3 of 6 JUN 1 7 2011 v Y: Section III, Project Information, no. 8 i at r d Basin Informatwn � ' ,. bDrainage Area,,(5) .. Receiving Stream Name Northeast Creek Stream Class SC;HQW;NSW Stream Index No 19-36- 3.5 Total Drainage Area (sf) 123,647 On -site Drainage Area (sf) 123,647 Off -site Drainage Area (sf) 0 Proposed Impervious Area (sf) 27,400 % Impervious Area (total) 22.0 $ �yC .rS�"I " ESAi' a,.l"-';- n 7 r 5 ,� .�k .�v� � Impervious Surface Area n o4... J.x]J+t_u Yni3v x:!i'x �,�a. Ya` x D x-, x. r r `.,�M1 y� d 40 � : ramage Area (5) n .8 R. 1_. On -site Buildings Area (sf) 19,200 On -site Streets Area (sf) 6,719 On -site Parking Area (sf) 0 On -site Sidewalks Area (sf) 1,481 Other On -site (sf) (Future) 0 Off -Site (sf) 0 Total sf 27,400 RECEIVED JUN 77 2011 BY: 'Report only that amount of existing BUA that will remain after development. Do not report any existing BUA that is to be removed and which will be replaced by new BUA. 11. How was the off -site impervious area listed above determined? Provide documentation. No off -site impervious areas Projects in Union Countv: Contact D1PQ Central Office staffto check ifthe project is located within a Threatened & Endangered Species watershed that may be subject to more stringent stormwater requirements as per NCAC 02B .0600. V. SUPPLEMENT AND O&M FORMS The applicable state stormwater management permit supplement and operation and maintenance (O&M) forms must be submitted for each BMP specified for this project. The latest versions of the forms can be downloaded from http://portal.nc(ietir.org/web/wq/ws/su/bmp-manual. VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below. A detailed application instruction sheet and BMP checklists are available from http://kiortal.ncdenr.org/web/wq/ws/su/statesw/forms does. The complete application package should be submitted to the appropriate DWQ Office. (The appropriate office may be found by locating project on the interactive online map at http://portal.ncdenr.org/web/wq/ws/su/maps.) Please indicate that the following required information have been provided by initialin in the space provided for each item. All original documents MUST be signed and initialed in blue ink. Download the latest versions for each submitted application package from hthi://portal.ncdenr.org/web/wq/ws/su/statesw/forms does. Initials 1. Original and one copy of the Stormwater Management Permit Application Form. A1-.O 2. Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants N A Form. (if required as per Part VII below) 3. Original of the applicable Supplement Form(s) (sealed, signed and dated) and O&M agreement(s) for each BMP. 4. Permit application processing fee of $505 payable to NCDENR. (For an Express review, refer to A LZ http:/ /www.envhelp.org/pages/onestopexpress.htmI for information on the Express program and the associated fees. Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required application meeting.) 5. A detailed narrative (one to two pages) describing the stormwater treatment/managementfor Pr Lb the project. This is required in addition to the brief summary provided in the Project Information, item 1. 6. A USGS map identifying the site location. If the receiving stream is reported as class SA or the A,-6 receiving stream drains to class SA waters within 1/ mile of the site boundary, include the 1A mile radius on the map. 7. Sealed, signed and dated calculations. A�-6 8. Two sets of plans folded to 8.5" x 14" (sealed, signed, & dated), including: Alb a. Development/Project name. b. Engineer and firm. c. Location map with named streets and NCSR numbers. d. Legend. e. North arrow. f. Scale. g. Revision number and dates. h. Identify all surface waters on the plans by delineating the normal pool elevation of impounded structures, the banks of streams and rivers, the MHW or NHW line of tidal waters, and any coastal wetlands landward of the MHW or NHW lines. • Delineate the vegetated buffer landward from the normal pool elevation of impounded structures, the banks of streams or rivers, and the MHW (or NHW) of tidal waters. i. Dimensioned property/project boundary with bearings & distances. j. Site Layout with all BUA identified and dimensioned. k. Existing contours, proposed contours, spot elevations, finished floor elevations. 1. Details of roads, drainage features, collection systems, and stormwater control measures. m. Wetlands delineated, or a note on the plans that none exist. (Must be delineated by a qualified person. Provide documentation of qualifications and identify the person who RECEZVF made the determination on the plans. n. Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations. SUN 1 ] 2011 Form SWU-101 Version 07Jun2010 Page 4 of 6 BY: o. Drainage areas delineated (included in the main set of plans, not as a separate document). p. Vegetated buffers (where required). Copy of any applicable soils report with the associated SHWT elevations (Please identify A Lg elevations in addition to depths) as well as a map of the boring locations with the existing elevations and boring logs. Include an 8.5"xll" copy of the NRCS County Soils map with the project area clearly delineated. For projects with infiltration BMPs, the report should also include the soil type, expected infiltration rate, and the method of determining the infiltration rate. (Infiltration Devices submitted to WiRO: Schedule a site visit for DWQ to verifij the SHINT prior to submittal, (910) 796-7378.) 10. A copy of the most current property deed. Deed book: N/A Page No: N/A N/A 11. For corporations and limited liability corporations (LLC): Provide documentation from the NC N / 4 Secretary of State or other official documentation, which supports the titles and positions held by the persons listed in Contact Information, item la, 2a, and/or 3a per NCAC 2H.1003(e). The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State, otherwise the Application will be returned. hn://www.secretarv.state.nc.us/Corporations/CSearch aspx VIL DEED RESTRICTIONS AND PROTECTIVE COVENANTS For all subdivisions, outparcels, and future development, the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot. If lot sizes vary significantly or the proposed BUA allocations vary, a table listing each lot number, lot size, and the allowable built -upon area must be provided as an attachment to the completed and notarized deed restriction form. The appropriate deed restrictions and protective covenants forms can be downloaded from hn://portal.ncdenr.org/web/wq/ws/su/statesw/forms does. Download the latest versions for each submittal. In the instances where the applicant is different than the property owner, it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded. By the notarized signature(s) below, the permit holder(s) certify that the recorded property restrictions and protective covenants for this project, if required, shall include all the items required in the permit and listed on the forms available on the website, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DWQ and that they will be recorded prior to the sale of any lot. VIII. CONSULTANT INFORMATION AND AUTHORIZATION Applicant: Complete this section if you wish to designate authority to another individual and/or firm (such as a consulting engineer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional information). Consulting Engineer:Anna Lee Bamforth, P.E., L.S., LEED AP Consulting Firm: C. Allan Bamforth, Jr., Engineer-Survevor, Ltd. Mailing Address:2207 Hampton Boulevard City:Norfolk State:VA Zip:23517 Phone: (757 1 627-7079 Emafl:alb@babmforth.com Fax: (757 ) 625-7431 IX. PROPERTY OWNER AUTHORIZATION (if Contact Information, item 2 has been filled out, complete this section) I, (print or hjpe name of person listed in Contact Information, item 2a) certify that I own the property identified in this permit application, and thus give permission to (print or type name of person listed in Contact Information, item la) with (print or type name of organization listed in Contact Information, item 1a) to develop the project as currently proposed. A copy of the lease agreement or pending property sales contract has been provided with the submittal, which indicates the party responsible for the operation and maintenance of the stormwater system. _rCEJVED LJUN 1 7 2011 Form SWU-101 Version 07Jun2010 Page 5 of 6 As the legal property owner I acknowledge, understand, and agree by my signature below, that if my designated agent (entity listed in Contact Information, item 1) dissolves their company and/or cancels or defaults on their lease agreement, or pending sale, responsibility for compliance with the DWQ Stormwater permit reverts back to me, the property owner. As the property owner, it is my responsibility to notifv DWQ immediately and submit a completed Name/Ownership Change Form within 30 days; otherwise I will be operating a stormwater treatment facility without a valid permit. I understand that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statue 143-215.1 and may result in appropriate enforcement action including the assessment of c' I,pennalties f up to 525,000 per day, pursuant to NCGS 143-215.6. Signature: (/A Date: I, A , a Notary Public for the State of County of �1/�!alJ do hereby certify that LC�/ /i personally appeared before me this �G "day of and ackk owledd(e�the due execution of the application for a stormwater permit. Witness my hand and official seal, (� if 7lDi 0 AUCE A. BONNETTE Notary Publle onslow County Btb rh C r X. APPLICANT'S CERTIFICATION SEAL My commission expires .Zfd),1�,12)11r I, (print or hjpe name of person listed in Contact Information, item la) certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of the applicable stormwater rules under 15A NCAC 21-1.1000, SL 2006-246 (Ph. II - Post Construction) or SL 2008-211. Signa a Notary Public for the State of do hereby certify that Date: County of personally appeared before me this _ day of and acknowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, Form SWU-101 Version 07Jun2010 SEAL My commission RECEIVED: Page 6of6 JUN 1 7 1011 BY: OTT og2(o For DENR Use ONLY Reviewer: �A North Carolina Department of Environment and - 8 /-•1 Submit: Natural Resources NCDENR Request for Express Permit Review Time: DIV Confine: FILL-IN all the information below and CHECK the Permits) you are requesting for express review. FAX or Email the completed form to Express Coordinator along with a completed DETAILED narrative, site plan (PDF file) and vicinity map (same items expected in the application package of the project location. Please include this form in the application package. • Asheville Region -Alison Davidson 828-296.4698;alison.davidson(ancmail.net • Fayetteville or Raleigh Region -David Lee 919-791.4203; daviddee(o)ncmail.net • Mooresville & -Patrick Grogan 704.663-3771 or patrick.grogan(a)ncmaiLnet • Washington Region -Lyn Hardison 252-946.9215 or Ivn.hardison(oDncmail.net • Wilmington Region -Janet Russell 910-350-2004 or(anet.russell(7g ncmail.net NOTE: Project application received after 12 noon will be stamped in the following work day. Project Name: PROJECT 110084 WOUNDED WARRIOR TRAILER SITE PREP County: ONSLOW Applicant: CARL H. BAKER JR., P.E. Company: MCB CAMP LEJEUNE Address: 1005 MICHAEL RD MCB City: CAMP LEJEUNE, State: NC Zip: 28547 Phone: 910-451-2213, Fax: 910-451-2927, Email: carl.h.baker@usmc.mil Physical Location:AT THE END OF HOSPITAL CORPS BLVD. OFF BREWSTER BLVD. Project Drains into NORTHEAST CREEK waters — Water classification SC. HOW. NSW (for classification see- h ttp://h 2o. en r. state. nc. u s/bims/reportstreportsW B. h tml) Project Located in WHITE OAK River Basin. Is project draining to class ORW waters? N , within Yz mile and and draining to class HQW waters? Y Engineer/Consultant: ANNA LEE BAMFORTH Company: C. ALLAN BAMFORTH, JR. Address: 2207 HAMPTON BLVD City: NORFOLK, State: VA Zip: 23517-_ Phone: 757-627-7079, Fax: 757-625-7434, Email: alb@bamforth.com SECTION ONE: REQUESTING A SCOPING MEETING ONLY C7C f e9 }Aejr o n ❑ Scoping Meeting ONLY ❑ DWQ, ❑ DCM, ❑ DLR, ❑ OTHER: Permits of request SW SW SW SW SW o ce-ervl waters N or within 1 mile MAY 2 7 2011 SECTION TWO: CHECK ONLY THE PROGRAM (S) YOU ARE REQUESTING FOR EXPRESS PERMITTING ❑ 401 Unit ❑ Stream Origin Determination: _ # of stream calls - Please attach TOPO map marking the areas in questions ❑ Intermittent/Perennial Determination: _ # of stream calls - Please attach TOPO map marking the areas in questions ❑ 401 Water Quality Certification ❑ Isolated Wetland (_linear It or _acres) ❑ Riparian Buffer Authorization El Minor Variance [I Major General Variance ® State Stormwater ❑ General ❑ SFR, ❑ SFR < 1 ac. ❑Bkhd & Bt Rmp, ❑ Clear & Grub, ❑ Utility ❑ Other ❑ Low Density ❑ Low Density -Curb & Gutter _ # Curb Outlet Swales ❑ Off -site [SW _ (Provide permit #)] ® High Density -Detention Pond _ # Treatment Systems ❑ High Density -Infiltration 1 #Treatment Systems ❑ High Density -Bio-Retention _ # Treatment Systems ❑ High Density -SW Wetlands _ # Treatment Systems ElHigh Density -Other _ # Treatment Systems /❑ MOD:❑ Major ❑ Minor ❑ Plan Revision ❑ Redev. Exclusion SW (Provide permit #) ❑ Coastal Management ❑ Excavation & Fill ❑ Bridges & Culverts ❑ Structures Information ❑ Upland Development ❑ Marina Development ❑ Urban Waterfront ❑ Land Quality ® Erosion and Sedimentation Control Plan with 2_8 acres to be disturbed.(CK # (for DENR use)) SECTION THREE — PLEASE CHECK ALL THAT IS APPLICABLE TO YOUR PROJECT (for both scooino and express meeting reauest Wetlands on Site ❑ Yes ® No Buffer Impacts: ❑ No ❑ YES: —acre(s) Wetlands Delineation has been completed: ❑ Yes ❑ No Isolated wetland on Property ❑ Yes ❑ No US ACOE Approval of Delineation completed: ❑ Yes ❑ No 404 Application in Process w/ US ACOE: ❑ Yes ❑ No Permit Received from US ACOE ❑ Yes ❑ No ++++++++++++a++++++aaa+aataaa+gaga++++++++++a+++++++++a+For DENR use onl}'aaaaaa+++aaa+aa+++++++++++++aaa+a++aa+saa++ss++as+aaaa+aata♦ Fee Solit for multiole oermits:Whack# 1 Total Fee Amount SUBMITTAL DATES Fee SUBMITTAL DATES Fee CAMA $ Variance (❑ Maj; ElMin) $ SW (❑ HD, ❑ LD, ❑ Gen) $ 401: $ LQS $ Stream Deter,_ $ NCDENR EXPRESS March 2009 MEMORY TRANSMISSION REPORT TIME :06-29-'11 12:18 FAX NO.1 :910-350-2018 NAME :DENR Wilmington FILE NO. 643 DATE 06.29 12:15 TO R 917576257434. DOCUMENT PAGES 9 START TIME 06.29 12:17 END TIME 06.29 12:18 PAGES SENT 9 STATUS OR *** SUCCESSFUL TX NOTICE *** 8mce or Nome ce.oue„ neper<mem er ¢ow.e..me..< eoa ive<..rei ne.o.,.re. Whim*eg<ou Reg)ona) OTc< , Be+e�y Bo�Yf P Nue, Gwereor FAX COVER 531F.:F.T Dae Fre�.waw� Secretary .=sw8��o9a� i-ice.-, .' � ir�o�--l-� ��m t/ ��✓— Li � i � � 2') Cp.alnW Ori�e L�zbnaionW�ImingionNC 2Rn0� o (9i0) 796-"12.3 o M Hqunl Opporu�n Ry A[Frm�iive Action 0mploy'v State of Norlb Carolina Department of Environment and Natural Resources Wilmington Regional Office Beverly Eaves Perdue, Governor FAX COVER SHEET Dee Freeman, Secretary Date: To: Co: Fax: Re: No. Pages (excl. cover): C From: Jo Casmer � Phone: (910) 796-7336 7 3� Fax: (910) 350-2004 //// i /7lOC✓ ' f i u_ �i o.% S S v�c� — f� 4 i C/ 127 Cardinal Drive Extension, Wilmington, NC 28405 c (910) 796-7215 o An Equal Opportunity Affirmative Action Employer l MEMORY TRANSMISSION REPORT TIME :06-29-'ll 12:16 FAX NO.1 :910-350-2018' NAME :DENR Wilmington FILE No. 642 DATE 06.29 12:14 TO : 8 919104512927 DOCUMENT PAGES 9 START TIME 06.29 12:14 END TIME 06.29 12:16 PAGES SENT 9 STATUS OK *** SUCCESSFUL TX NOTICE *** 8tnte of NnRb Carolina Dapnrtmnnt of Qav�ronmeot and Nn<ure� Raourcu Wum)u¢too ReQ�onu� OflOee , am+er/y � PerWr. Governor FA..X COVRR SIIEFT nee Frm.noa. Se¢retnry pate: �A—� !'�� No. PHHCB Cexcl, cover): Too G �pG G �j' AiT/'/' From: Jo Cnem¢r C �27CvdInW 1)riv� Sve.+�l«L WIln�inQtory NC 2NIOJ � (9 �0)']96-"12i5 � M Equal Oppora��nlay Af11�na�lve Aa�fOn 4'mpluycr I 10 State of North Carolina Department of Environment and Natural Resources Wilmington Regional OMce Beverly Eaves Perdue, Governor FAX COVER SHEET Dee Freeman, Secretary To: �� G=/ �l From: Jo Casmer Co: i✓Phone: (910) 796-7336 Fax: 9�� `fs� - a is Fax: (910) 350-2004 Re: GLJOd��rd �'aii,'o� �/% ��r.� w_,'7��'e� Soi 8 a iD 9�6 / M , - /%�%O C7 i- G !s -/ D / S S Ul c�— /7 R r �✓ G O �7 1912 127 Cardinal Drive Extension, Wilmington, NC 28405 o (910) 796-7215 o An Equal Opportunity Affirmative Action Employer yA11f'pH q t s C. ALLAN BAMFORTH, JR. ENGINEER -SURVEYOR, LTD. OFFICE: MAILING ADDRESS 2207 HAMPTON BLVD. P.O. Box 6377 NORFOLK, VA 23517 NORFOLK, VA 23508 PHONE: (757) 627-7079 FAX:757-625-7434 E-mail: dwc@bamforth.com To: NCDENR Wilmington Regional office 127 N. Cardinal Dr. Express Permits Wilmington, NC 28405 WE ARE SENDING YOU THE FOLLOWING ITEMS: ❑ Attached ❑ Shop Drawings ❑ Prints ❑ Specifications ❑ Copy of Letter LETTER OF TRANSMITTAL DATE: June 17, 2011 JOB 11.009 ATTN: Mr. Chris Baker RE: Wounded Warrior Trailer Site Prep, MCB Camp Lejeune, NC ❑ Under separate cover via 0 Plans ❑ Reports ❑ Calculations ❑ Other COPIES DATE NO. DESCRIPTION 2 REVISED PLANS —FULL SIZE THESE ARE TRANSMITTED AS CHECKED BELOW: ❑ For Your Use ❑ For Approval ❑ Shop Drawing Action as Noted ❑ As Requested 0 For Review & Comment REMARKS: RECEIVED JUN 2 0 2011 BY: COPY TO: Anna Lee Bamforth, P.E., L.S., LEED AP ANNA LEE BAMFORTH, RE.. L.S. C. ALLAN BAMFORTH, JR., P.E., L.S. LINDA Z. BAMFORTH RICHARD E. GARRIOTT, P. E. RICHARD W. CLARK, L.S. DAVID W. CAMPBELL C. ALLAN BAMFORTH, JR. ENGINEER - SURVEYOR, LTD. EST. 1977 June 10, 2011 Mr. Chris Baker North Carolina Department of Environment and Natural Resources Division of Water. Quality Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 RE: P110084 Wounded Warrior Trailer Site Prep Dear Mr. Baker, Please find attached two (2) copies of revised plans; one (1) copy of revised SWU-101 application; one (1) copy of a USGS vicinity map; one (1) copy of the Stormwater Narrative; one (1) copy of Civil Calculations; one (1) copy of the Wet Basin supplement; one (1) copy of the Wet Basin O&M supplement: one (1) copy of Specifications and one (1) copy of the Geotechnical Report. Our responses to NCDENR comments received June 8, 2011 are as follows: 1. Revise impervious areas on the application for existing drainage areas nos. 2 and 3. Revised application attached. Revised areas added to plan sheet CS100. 2. Add note to plans stating stormwater pipe and structures shall be cleaned before acceptance by the Officer in Charge of Construction. Added note to plan sheet CS102. 3. Label proposed drainage area — Drainage Area no. 5. Added label to plan sheet CS100.. 4. Add Drainage area no. 5 to Section IV of the SWU-101 application. Attached additional drainage area to the SWU-101 application. 5. Revise drainage area no. 3 on sheet CS100 to include area around pipe to pond. Proposed area should go around this area. Revised drainage area shown on plan sheet CS100. RF�^�VED JUN 1. 3 2011 i 2207 HAMPTON BOULEVARD, NORFOLK, VIRGINIA 23517 1 R0, BOX 6377, NORFOLK, VIRGINIA 23508 TEL: (757) 627-7079 1 FAX: (757) 625-7434 1 E-MAIL: ALB@BAMFORTH.COM June 10, 2011 Mr. Chris Baker NCDENR . Division of Water Quality P110084 Wounded Warrior Trailer Site Prep Page 2 Please do not hesitate to contact us should you have any questions or require additional information. Sincerely, Anna Lee Bamforth, P.E., L.S., LEED AP President JUN 1 3 2011 CIVIL CALCULATIONS PROJECT 110084 WOUNDED WARRIOR JUN 1 3 2011 BY: TRAILER PREP SITE MARINE CORPS BASE CAMP LEJEUNE, NORTH CAROLINA C. ALLAN BAMFORTH, JR., ENGINEER -SURVEYOR, LTD NORFOLK, VIRGINIA June 2011 ���UIt1) �'�C a SEAL 029841 = EEl h0�pl\\,� PROJECT 110084 WOUNDED WARRIOR TRAILER SITE PREP BMP CALCULATIONS Basis of Desion: The Wounded Warrior project involves the preparation of the site for trailers and supporting areas. There is currently no impervious area except for existing roads bordering the project site. All of the new impervious along with some of the existing roadway drains to the BMP. The BMP is designed for future construction to accommodate an additional 8 trailers and associated walks. The BMP is designed for both quantity and quality volumes. Quality volume was determined using the runoff volume from the first inch and a half of rain, to be released in 2 to 5 days. The quantity design is based on the rational method using a ten year storm and Wilmington I-D-F curve. Time of concentration was found using Seelye's Chart for overland flow and Kirpich Chart for ditch flow. Calculations were also performed for the I-yr, 24 hour storm using Soil Group B. The BMP design is a wet detention basin and was sized with the Haestad Methods "PondPack" software. It is in conformance with North Carolina Division of Water Quality "Stormwater Best Management Practices Manual, July 2007". Predevelopment: Total Area — 2.84 acres (1.69 current site + 1.15 future) Impervious — 0.19 acres (0.11 current site + 0.08 future) C = 0.95 Grass — 2.65 acres (1.43 current site + 0.92 future) C = 0.30 1-Yr. 24-Hour Storm Pre — 1.32 cfs Time of Concentration Seelye's Chart for Overland Plow: L = 200 ft Slope = (19.5 — 17.5)/200 = I % Kirpich Chart for Ditch Flow: L = 240 ft Height = (17.5 — 16.5) = I' Total T, = 26 minutes T, = 17 minutes C = 0.30 T, = 4.5 x 2 = 9 minutes Paget JU I1 3 2011 BY: PROJECT 110084 WOUNDED WARRIOR TRAILER SITE PREP BMP CALCULATIONS Rainfall Intensity Wilmington I-D-F Curve, 10-Year Storm, 26 minutes 1 = 3.95 in/hr Allowable Discharge — Use all Grass Q (I0-Year)= CAI = (2.84 x 0.30) x 3.95 = 3.37 cfs Postdevelopment: Total Area — 2.84 acres (1.69 current site + 1.15 future) Impervious — 0.63 acres (0.33 current site + 0.30 future) C = 0.95 Grass — 2.21 acres (1.36 current site + 0.85 future) C = 0.30 1-Yr. 24-Hour Stonn Post — 2.02 cfs Time of Concentration Seelye's Chart for Overland Flow: L = 27 ft Slope = (19.3 — 18.6)/27 — 2.6% T, = minutes C = 0.30 Kirpich Chart for Ditch Flow: L = 43 ft Height = (18.6 — 17.7) = 0.9' T, = minutes Manning's Equation for Pipe Flow: L = 405 ft Velocity = 2.5 ft/sec T, = minutes Total Tc = 23 minutes Temporary Water Quality Volume Required Use "Simple Method" by Schueler to Determine Runoff Volume for One and a Halt=Inch Storm Over Site: Site Area = 123.647 sf Impervious = 27,400 sf Runoff Coefficient = Rv = 0.05 + 0.009(I) 1= Percent Impervious = 27400/123647 = 22% Page 2 RE 'i V-EED JUN 1 3 2011 BY: PROJECT 110084 WOUNDED WARRIOR TRAILER SITE PREP BMP CALCULATIONS Rv = 0.05 + 0.009(22) = 0.25 in/in Volume = (Design Rainfall) x (Rv) x (Drainage Area) Volume = (1.5 in rainfall)/(I2 in) x (0.25 in/in) x (123647 so = 3864 cu-ft Average Depth of BMP dave = Average Depth Abs = Area of Bottom Shelf Apb = Area of Pond Bottom PP = Permanent Pool Area dave = 0.25(1 + Abs/PP) + (((Abs + Apb)/2) x depth)/Abs dave = 0.25(1 + 4235/6075) + (((4235 + 891)/2) x (4.5/4235) = 3.0 OK Required Area of Permanent Pool From Stormwater Best Management Practices Manual, July 2007: 22% impervious, depth = 3.0, 90% TSS, SA/DA = 2.62 Required Area of Permanent Pool = SA/DA/l00 x A = 2.62/100 x 123647 = 3240 sq ft Size Orifice to Discharge Within 2 to 5 Days A = orifice area, WQV = water quality volume, C = 0.60, g = 32.2, h = head Q = WQV/4 days Q = 5023 cu ft/4 days = 0.015 efs Q = CA(2gh)11' 0.015 = 0.6A(2x32.2x0.30)" A = 0.0057 sq ft Diameter = I inch Page 3 "V JUN 1 3 2011 B_ PROJECT 110084 WOUNDED WARRIOR TRAILER SITE PREP BMP CALCULATIONS Summary of Results: Minimum Forebay Volume = Permanent Pool Volume x 20% = 12007 x 0.20 = 2401 cu. ft. Forebay Volume Provided = 3484 cu. ft. Required Temporary Pool Volume = 3864 cu. ft. Volume Provided for Temporary Pool = 4286 cu. ft Required Area for Penmanent Pool = 3240 sq. ft. Area Provided for Permanent Pool (not over forebay) = 4050 sq. ft. Allowable Outflow (I0-YearStonn) = 3.37 cfs Outlet Structure — 1.5 foot x 9 inch Rectangular Orifice at Elevation 14.10 Peak Outflow for 10-Year Storm = 2.59 cfs at Elevation 14.69 feet Page 4 RE "Ei -H- ij JUN 1 3 2011 BY: Type.... SCS Unit Hyd. Summary Page 4.03 Name.... SCS UH 10 Tag: 1 Event: 1 yr File.... K:\JOB-FILES\2011\11009\CALCS\DENR 052511\BMP PRE 1YR.PPW Storm... TypeIII 24hr Tag: ..1 SCS UNIT HYDROGRAPH METHOD STORM EVENT: 1 year storm Duration = 1440.00 min Rain Depth = 3.6700 in Rain Dir = C:\HAESTAD\PPKW\RAINFALL\ Rain File -ID = SCSTYPES.RNF - TypeIII 24hr Unit Hyd Type = Default Curvilinear HYG Dir = K:\JOB-FILES\2011\11009\CALCS\DENR 052511\ HYG File - ID = - SCS UH 10 ..1 Tc . = 26.00 min Drainage Area = 2.840 acres Runoff CN= 64 -------------------------------------------- - -------------------------------- Computational Time Increment = 3.467 min Computed Peak Time = 741.87 min Computed Peak Flow = 1.33 cfs Time Increment for HYG File = 3.00 min Peak Time, Interpolated Output = 744.00 min Peak Flow, Interpolated Output = 1.32 cfs DRAINAGE AREA ID:None Selected CN = 64 Area = 2.840 acres S = 5.6250 in 0.2S = 1.1250 in Cumulative Runoff ------------------- .7928 in 8173 cu.ft HYG Volume... 8174 cu.ft (area under HYG curve) ***** UNIT HYDROGRAPH PARAMETERS ***** Time Concentration, Tc = 26.000 min (ID: None Selected) Computational Incr, Tm = 3.467 min = 0.20000 Tp Unit Hyd. Shape Factor = 483.432 (37.46% under rising limb) K = 483.43/645.333, K = .7491 (also, K = 2/(1+(Tr/Tp)) Receding/Rising, Tr/Tp = 1.6698 (solved from K = .7491) Unit peak, qp = 7.43 cfs Unit peak time Tp = 17.333 min Unit receding limb, Tr = 69.333 min Total unit time, Tb = 86.667 min S/N: 121901A06A84 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 13:20:07 Date: 05-19-2011 JUN 1 3 2011 Type.... SCS Unit Hyd. Summary Page 3.03 Name.... SCS UH 10 Tag: ..1 Event: 1 yr File.... K:\JOB-FILES\2011\11009\CALCS\DENR 052511\BMP PRE 1YR.PPW SCS UNIT HYDROGRAPH METHOD STORM EVENT: 1 year storm Duration = 1440.00 min Rain Depth = 3.6700 in Rain Din = C:\HAESTAD\PPKW\RAINFALL\ Rain File -ID = SCSTYPES.RNF - TypeIII 24hr Unit Hyd Type = Default Curvilinear HYG Din = K:\JOB-FILES\2011\11009\CALCS\DENR 052511\ HYG File - ID = WORK PAD.HYG - SCS UH 10 ..1 Tc = 23.00 min Drainage Area = 2.840 acres Runoff CN= 69 -------------------------------------------- Computational Time Increment = 3.067 min Computed Peak Time = 739.07 min Computed Peak Flow = 2.03 cfs Time Increment for HYG File = 3.00 min Peak Time, Interpolated Output = 738.00 min Peak Flow, Interpolated Output = 2.02 cfs DRAINAGE AREA ID:None Selected CN = 69 Area = 2.840 acres S = 4.4928 in 0.2S = .8986 in Cumulative Runoff --------- 1.0574 in 10901 cu.ft HYG Volume... 10898 cu.ft (area under HYG curve) ***** UNIT HYDROGRAPH PARAMETERS ***** Time Concentration, Tc = 23.000 min (ID: None Selected) Computational Incr, Tm = 3.067 min = 0.20000 Tp Unit Hyd. Shape Factor = 483.432 (37.46% under rising limb) K = 483.43/645.333, K =• .7491 (also, K = 2/(1+(Tr/Tp)) Receding/Rising, Tr/Tp = 1.6698 (solved from K = .7491) Unit peak, qp = 8.39 cfs Unit peak time Tp = 15.333 min Unit receding limb, Tr = 61.333 min Total unit time, Tb = 76.667 min ' S/N: 121901A06A84 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 13:20:52 Date: 05-19-2011 SVL%�lt-JY Y L� JUN 1 3 2011 BY: Type.... Vol: Elev-Area Page 1.01 Name.... P 10 File.... K:\JOB-FILES\2011\11009\CALCS\DENR 052511\FOREBAY.PPW Elevation Planimeter Area Al+A2+sgr(A1*A2) Volume Volume Sum (ft) ------------------------------------------------------------------------ (sq.in) (sq.ft) (sq.ft) (cu.ft) (cu.ft) 9.00 ----- 187 0 0 0 13.00 ----- 1295 1974 2632 2632 13.50 ----- 2150 5114 852 3484 POND VOLUME EQUATIONS * Incremental volume computed by the Conic Method for Reservoir Volumes. Volume = (1/3) * (EL2-EL1) * (Areal + Area2 + sq.rt.(Areal*Areal)) where: EL1, EL2 = Lower and upper elevations of the increment Areal,Area2 = Areas computed for EL1, EL2, respectively Volume = Incremental volume between EL1 and EL2 S/N: 121901A06A84 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 16:22:29 Date: 06-05-2011 t-ZZ5C E: VTzn JUN 1 3 2011 F3Y: Table of Contents i Table of Contents tt******»x**********txt POND VOLUMES ***************»tx***** P 10........... Vol: Elev-Area ..................... 1.01 OUTLET STRUCTURES PR IDA......... Outlet Input Data .................. 2.01 »»******xx»xx»ttattx*xx POND ROUTING x»»»t»ttt»xt**x»x»»»t»t P .10........... Pond E-V-Q Table ................... 3.01 P 10 OUT wi110 Pond Routing Summary 3.03 x xtt»»»*t*xxxxx»»t RATIONAL METHOD CALCS »»»tx»x*t*****»»»»» MOD.RAT NET 10 wi110 Mod. Rational Graph ................ 4.01 S/N: 121901A06A84 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 16:13:13 Date: 06-05-2011 JUN 1 3 2011 BY: Type.... Vol: Elev-Area Name.... P 10 Page 1.01 File.... K:\JOB-FILES\2011\11009\CALCS\DENR 052511\BMP WITH FUTURE TRAILERS.PPW Elevation Planimeter Area Al+A2+sgr(A1*A2) Volume Volume Sum (ft) (sq.in) -------------- (sq.ft) (sq.ft) (cu.ft) (cu.ft) 9.00 ----- 891 ------------ 0 0 ---------- 0 13.00 ----- 4235 7069 9425 9425 13.50 ----- 6075 15382 2564 11988 14.00 ----- 7975 21010 3502 15490 17.00 ----- 11899 29615 29615 45106 17.50 ----- 12540 36654 6109 51215 POND VOLUME EQUATIONS * Incremental volume computed by the Conic Method for Reservoir Volumes. Volume = (1/3).* (EL2-EL1) *, (Areal + Area2 + sq.rt.(Areal*Areal)) where: ELI., EL2 = Lower and upper elevations of the increment Areal,Area2 = Areas computed for EL1, EL2, respectively Volume = Incremental volume between EL1 and EL2 S/N: 121901A06A84 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 16:13:13 Date: 06-05-2011 JUN 1 3 2011 Type.... Outlet Input Data Name.... PR 10A Page 2.01 File.... K:\JOB-FILES\2011\11009\CALCS\DENR 052511\BMP WITH FUTURE TRAILERS.PPW REQUESTED POND WS ELEVATIONS: Min. Elev.= 9.00 ft Increment = .20 ft Max. Elev.= 17.50 ft OUTLET CONNECTIVITY ---> Forward Flow Only (UpStream to DnStream) <--- Reverse Flow Only (DnStream to UpStream) < ---> Forward and Reverse Both Allowed Structure No. Outfall El, ft E2, ft ------ -- ----------------------------- Orifice-Area ---> TW 14.100 17.500 TW SETUP, DS Channel S/N: 121901A06A84 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 16:13:13 Date: 06-05-2011 C -1'11ED JUN 1 3 2011 JBY: Type.... Outlet Input Data Name.... PR 10A Page 2.02 File.... K:\JOB-FILES\2011\11009\CALCS\DENR 052511\BMP WITH FUTURE TRAILERS.PPW OUTLET STRUCTURE INPUT DATA Structure ID Structure Type = Orifice -Area # of Openings = 1 Invert Elev. = 14.10 ft Area = 1.1250 sq.ft Top of Orifice = 14.85 ft Datum Elev. = 14.48 ft Orifice Coeff. _ .600 Structure ID = TW Structure Type = TW SETUP, DS Channel ------------------------------------ FREE OUTFALL CONDITIONS SPECIFIED CONVERGENCE TOLERANCES Maximum Iterations= 30 Min. TW tolerance = .01 ft Max. TW tolerance = .01 ft Min. HW tolerance = .01 ft Max. HW tolerance = .01 ft Min. Q tolerance = .10 cfs Max. Q tolerance = .10 cfs S/N: 121901A06A84 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 16:13:13 Date: 06-05-2011 RECE:x '1- JUN 1 3 2011 BY:_--- Type.... Pond E-V-Q Table Page 3.01 Name.... P 10 File.... K:\JOB-FILES\2011\11009\CALCS\DENR 052511\BMP WITH FUTURE TRAILERS.PPW LEVEL POOL ROUTING DATA HYG Dir = K:\JOB-FILES\2011\11009\CALCS\DENR 052511\ Inflow HYG file = NONE STORED - P 10 IN wi110 Outflow HYG file = NONE STORED - P 10 OUT wi110 Pond Node Data = P 10 Pond Volume Data = P 10 Pond Outlet Data = PR l0A No Infiltration INITIAL CONDITIONS ---------------------------------- Starting WS Elev = 14.10 ft Starting Volume = 16294 cu.ft Starting Outflow = .00 cfs Starting Infiltr. _ .00 cfs Starting Total Qout= .00 cfs Time Increment = 1.00 min Elevation Outflow Storage Area Infilt. Q Total 2S/t + 0 ft ------------------------------------------------------------------------------ cfs cu.ft sq.ft cfs cfs cfs 9.00 .00 0 891 .00 .00 .00 9.20 .00 189 999 .00 .00 6.30 9.40 .00 400 1114 .00 .00 13.34 9.60 .00 635 1234 .00 .00 21.16 9.80 .00 894 1361 .00 .00 29.81 10.00 .00 1180 1494 .00 .00 39.32 10.20 .00 1492 1634 .00 .00 49.75 10.40 .00 1834 1779 .00 .00 61.12 10.60 .00 2204 1931 .00 .00 73.48 10.80 .00 2606 2089 .00 .00 86.88 11.00 .00 3040 2253 .00 .00 101.34 11.20 .00 3508 2423 .00 .00 116.93 11.40 .00 4010 2600 .00 .00 133.67 11.60 .00 4548 2782 .00 .00 151.60 11.80 .00 5123 2971 .00 .00 170.78 12.00 .00 5737 3166 .00 .00 191.23 12.20 .00 6390 3368 .00 .00 213.01 12.40 .00 7084 3575 .00 .00 236.15 12.60 .00 7821 3789 .00 .00 260.69 12.80 .00 8600 4009 .00 .00 286.68 13.00 .00 9425 4235 .00 .00 314.16 13.20 .00 10340 4931 .00 .00 344.68 13.40 .00 11401 5681 .00 .00 380.02 S/N: 121901A06A84 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 16:13:13 Date: 06-05-2011 JUN 1 3 2011 Type.... Pond E-V-Q Table Page 3.02 Name.... P 10 File.... K:\JOB-FILES\2011\11009\CALCS\DENR 052511\BMP WITH FUTURE TRAILERS.PPW LEVEL POOL ROUTING DATA HYG Dir = K:\JOB-FILES\2011\11009\CALCS\DENR 052511\ Inflow HYG file = NONE STORED - P 10 IN wi110 Outflow HYG file = NONE STORED - P 10 OUT wi110 Pond Node Data = P 10 Pond Volume Data = P 10 Pond Outlet Data = PR 10A No Infiltration INITIAL CONDITIONS ---------------------------------- Starting WS Elev = 14.10 ft Starting Volume = 16294 cu.ft Starting Outflow = .00 cfs Starting Infiltr. _ .00 cfs Starting Total Qout= .00 cfs Time Increment = 1.00 min Elevation Outflow Storage Area Infilt. Q Total 2S/t + 0 ft ------------------- cfs cu.ft sq.ft cfs cfs cfs 13.60 .00 --------------------------------------------------- 12614 6434 .00 .00 420.46 13.80 .00 13975 7184 .00 .00 465.83 14.00 .00 15490 7975 .00 .00 516.34 14.10 .00 16294 8093 .00 .00 543.12 14.20 .44 17109 8212 .00 .44 570.73 14.40 1.32 18775 8453 .00 1.32 627.16 14.60 2.20 20490 8697 .00 2.20 685.20 14.80 3.07 22254 8945 .00 3.07 744.89 15.00 3.90 24068 9196 .00 3.90 806.18 15.20 4.59 25933 9451 .00 4.59 869.03 15.40 5.19 27849 9709 .00 5.19 933.49 15.60 5.73 29817 9970 .00 5.73 999.62 15.80 6.22 31837 10236 .00 6.22 1067.46 16.00 6.68 33911 10504 .00 6.68 1137.05 16.20 7.10 36039 10776 .00 7.10 1208.41 16.40 7.50 38222 11052 .00 7.50 1281.56 16.60 7.88 40460 11331 .00 7.88 1356.55 16.80 8.25 42754 11613 .00 8.25 1433.39 17.00 8.60 45106 11899 .00 8.60 1512.11 17.20 8.93 47511 12153 .00 8.93 1592.62 17.40 9.25 49967 12410 .00 9.25 1674.82 17.50 9.41 51215 12540 .00 9.41 1716.56 5/N: 121901A06A84 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 16:13:13 Date: 06-05-2011 JUN 1 3 2011 Type.... Pond Routing Summary Page 3.03 Name.... P 10 OUT Tag: wi110 Event: 10 yr File.... K:\JOB-FILES\2011\11009\CALCS\DENR 052511\BMP WITH FUTURE TRAILERS.PPW Storm... IDF tbl 10 Tag: wi110 LEVEL POOL ROUTING SUMMARY HYG Dir = K:\JOB-FILES\2011\11009\CALCS\DENR 052511\ Inflow HYG file = NONE STORED - P 10 IN wi110 Outflow HYG file = NONE STORED - P 10 OUT wi110 Pond Node Data = P 10 Pond Volume Data = P 10 Pond Outlet Data = PR IDA No Infiltration INITIAL CONDITIONS ---------------------------------- Starting WS Elev = 14.10 ft Starting Volume = 16294 cu.ft Starting Outflow = .00 cfs Starting Infiltr. _ .00 cfs Starting Total Qout= .00 cfs Time Increment = 1.00 min INFLOW/OUTFLOW HYDROGRAPH SUMMARY Peak Inflow = 3.69 cfs at 23.00 min Peak Outflow = 2.59 cfs at 54.00 min ----------------------------------------------------- Peak Elevation = 14.69 ft Peak ----------------------------------------------------- ----------------------------------------------------- Storage = 21281 cu.ft MASS BALANCE (cu.ft) + Initial Vol = 16294 + HYG Vol IN = 10624 - Infiltration = 0 - HYG Vol OUT = 10619 - Retained Vol = 16299 Unrouted Vol = - cu.ft (.001% of Inflow Volume) S/N: 121901A06A84 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 16:13:13 Date: 06-05-2011 8` ECEz Ti V Z' JUN 1 3 2011 BY:�_ Type.... Mod. Rational Graph Page 4.01 Name.... MOD.RAT NET 10 Tag: wi110 Event: 10 yr File.... K:\JOB-FILES\2011\11009\CALCS\DENR 052511\BMP WITH FUTURE TRAILERS.PPW Storm... IDF tbl 10 Tag: wi110 MODIFIED RATIONAL METHOD ---- Graphical Summary for Maximum Required Storage ---- Method I Q = CiA * Units Conversion; Where Conversion = 43560 / (12 * 3600) * RETURN FREQUENCY: 10 yr Allowable Outflow: 3.37 cfs * 'C' Adjustment: 1.000 1 Required Storage: 3446 cu.ft '--------------------------------------------------------- k Peak Inflow: 3.69 cfs * .HYG File: wi110 }R}########R##}#R###########R##kR##R#rt#R####k#RRR#RR#R###R############ Td = 48.00 min Duration for Max. Storage Tc= 23.00 min I = 4.2000 in/hr Q = 5.34 cfs I I I I I I I I I I x x x x x I x 1 x x x o Ix 0 to ----------------------- I I I I I I I I Required Storage I 3446 cu.ft I I x xIx x x x x x x x x x x I Return Freq: 10 yr C adj.factor:1.000 Area = 2.840 acres Weighted C = .444 Adjusted C = .444 Td= 48.00 min I = 2.9000 in/hr Q = 3.69 cfs x o Q = 3.37 cfs 0 Ix (Allow.Outflow) o NOT TO SCALE x ------------ 1 x ---------- I--- 49.99 min T S/N: 121901A06A84 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 16:13:13 Date: 06-05-2011 JUN 1 3 2011 BY: Appendix A A-1 Index of Starting Page Numbers for ID Names ----- P ----- P 10... 1.01, 3.01, 3.03 PR 10A... 2.01 S/N: 121901A06A64 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 16:13:13 Date: 06-05-2011 JUN 1 3 2011 BY: Appendix A A-1 Index of Starting Page Numbers for ID Names P ----- P 10... 1.01, 3.01, 3.03 PR 10A... 2.01 S/N: 121901AOGA84 C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. PondPack Ver: 7.0 (325) Compute Time: 09:51:50 Date: 05-24-2011 JUN 1 3 2011 B. Y: C. Allan Bamforth, Jr. Engineer -Surveyor, Ltd. Norfolk, Virginia Project Number: 11.009 Project Name: Wounded Warrior Designed By: ATM Location: Camp Lejeune Sheet 1 Date: 05/11 STORM SEWER DESIGN COMPUTATIONS `.- From Point To Point -Area ;Drain ' 'A' � Run' off ' Coeff CA �� � - Inlet Time Rain, :• Fall Runoff D'CFS - ,InveRElevations„ - � . length • of Pipe Slope of ''Pipe Dia of Pip " - Vel of. Pipes t Capac =ity "Flow - Time TOp Pipe Elev 'Rim Elev Cover=: er+ - Remarks-� " ; - - Acres C rincre- ` ment A'ccum : ulated, (min) min '. in (") Incre ment : ,Accum' - "' > ulaleb Upper End' - Lower` End ft ' ' O_ / - .(fUft) a- - (in) (fps). ' (cfs) , (min) ' -- (ft) - (fQ - (ft) ' ar 1 2 0.18 0.54 0.10 0.10 0.00 14.24 13.86 150 0.0025 15 2.64 3.24 0.95 15.68 17.70 2.02 A = 2908 C = 0.95 A= 5106 C=0.30 2 4 0.24 0.43 0.10 0.20 0.00 13.86 13.61 98 0.0025 15 2.64 3.24 0.62 15.30 16.80 1.50 A = 1994 C = 0.95 A = 8342 C = 0.30 3 4 0.22 0.54 0.12 0.12 0.00 13.99 13.61 150 0.0025 15 2.64 3.24 0.95 15.43 17.70 2.27 A A= 6111 C=0.30 4 6 0.19 0.48 0.09 0.41 0.00 13.61 13.36 98 0.0025 15 2.64 3.24 0.62 15.05 16.80 1.75 A = 2400 C = 0.95 A = 6036 C = 0.30 5 6 0.25 0.44 0.11 0.11 0.00 13.74 13.36 150 0.0025 15 2.64 3.24 0.95 15.18 16.70 1.52 °` = 2441 C = 0.95 A = 8641 C = 0.30 6 7 0.21 0.39 0.08 0.60 10.0 3.60 10.61 10.50 55 0.0020 24 3.23 10.14 0.28 12.86 16.70 3.84 A = 1200 C = 0.95 A = 7942 C = 0.30 6.0 1.00 0.50 0.50 1.10 10.0 6.60 Future site 6.0 8 9 - - - - 3.00 9.00 8.38 308 0.0020 18 2.67 4.71 1.92 10.71 15.00 4.29 Out BMP JUN 1 3 2011 BY: Sediment Trap Calculations • it • -2r Y i JUN 1 3 2011 Pl 10084 Wounded Warrior Trailer Prep Site Sediment Trap Calculations MCB Camp Lejeune, NC Basis of Design: Size Sediment Traps for Compass Rose site using the North Carolina Erosion and Sediment Control Planning and Design Manual. Design Parameters: Minimum Volume = 3600 cu. ft. per acre of Disturbed Area Minimum Surface Area = 435 Square Feet / Q10 Peak inflow Minimum Depth = 3.5 feet, 1.5 feet below grade Minimum L/W Ratio = 2:1 Calculations: Basin 1: Q10 Peak inflow = 3.80 cfs C=0.30 I = 7.5 in/hr Disturbed Area — 1.69 acres Surface Area Required = 435 sf x 3.80 cfs = 1,653 sf / Q10 Surface Area Provided at elevation 13.0 ft. = 7,069 sf OK Volume Required = 3600 cu. ft. x 1.69 acres = 6,084 cu. ft. Volume Provided at elevation 13.0 ft = 9,425 cu. ft. OK June/11 GH jUN 1 3 2011 Silt Fence Calculations JUN 1 3 2011 P 110084Wounded Warrior Trailer Site Prep June/11 Sediment Fence Calculations GH MCB Camp Lejeune, NC Design Criteria: From North Carolina Erosion and Sediment Control Manual, revised . 0106, Chapter 6, section 6.62. Maximum Allowable = 25 ae / 100 ft of Silt Fence Given: Area = 1.69 Ac Silt Fence Length = 1,993 LF Slope < 2.0 % 1,9931f Silt Fence 1 s= 19.93 Hundred Ft of Silt Fence Site 100 Lf 1.7 A z 1 _.0.085 Ac per 100 Ft of Silt Fence, OK Site 19.93 Silt Fence JF,D JUN 1 3 2011 In CD101 I TRA�R MIE PkCP 1MAY 3 1 2011 5V f-SITE LOCATION E3�� NAVAL HOL SPRAL 09 C a ,1 i PJ MAY 3 1 Z011 F 5LCrPU9-QATA RIPE VAT o� Oom OOX O� O4 le w I F �iI L• �. RIC 0 IIC SCALE u YWXO[0 v MpP IMl[P LI[[ MAY 3 1 " 011 fl tJ d N , OMIN4GE PAFA i1HtE � \� I. I E, mm. , CS104 GNSHGGWF _we _ _ VDVxD[D�gRq }ggR19 A i.a L-3 —'L__P P � :PutaWE .wFA uw [v MAY 3 1 2011 PROJECT 110084 WOUNDED WARRIOR TRAILER PREP SITE MCB CAMP LEJEUNE, NORTH CAROLINA Stormwater Narrative: This project will construct a prep site for trailers at the Wounded Warrior site. Included on the site are associated wood walks and ramps to support the facility. The design also includes utility connections and stormwater management. The site is 1.69 acres and includes 0.11 acres of existing impervious and 0.33 acres of proposed impervious. Stormwater management will be provided by a wet detention basin on site. From the BMP it will discharge into the existing ditch. The BMP is sized for both the current site and a future trailer prep area site, to be located below the project. The future site is 1.15 acres with 0.08 acres of existing impervious and 0.30 acres of new impervious. Therefore, the BMP is sized for 2.84 acres with 0.63 acres of impervious. The site covers approximately 2.8 acres and is located on Hospital Corps Boulevard, off Brewster Boulevard on the Marine Corps Base, Camp Lejeune, North Carolina. The site is predominately wooded. Ground elevations vary from approximately 21.0 along Hospital Corps Boulevard to approximately 8.0 at the southwest limit. The average elevation is 17.5, near the middle of the site. The project site is located in SC, HQW, NSW waters. The quality volume is calculated using the runoff volume for the 1-year, 24-hour storm. Quality volume is satisfied by a wet detention BMP. The wet detention BMP is also sized to handle the quantity volume, based on the rational method using a ten year storm and Wilmington I-D-F curve. The BMP is designed in conformance with North Carolina Division of Water Quality "Stormwater Best Management Practices Manual, July 2007". All Built Upon Area will be collected. There is no Off -Site Runoff coming onto the site or into the proposed BMP. The receiving stream is the Northeast Creek, stream class SC; HQW; NSW, stream index number 19-16. Road construction across other property will not be necessary to access this project. An on site soil evaluation was performed in April 2011. At the basin site, soil infiltration rates measured approximately 1.7 to 3.6 inches per hour at depths ranged from about 1.5 to 2 feet below existing site grades. No groundwater was encountered in the borings during the exploration. Based on water levels obtained in nearby basins, the estimated seasonal high water table (SHWT) was determined to be about 13.5. 7,P - CEIVEI� MAY272011 ir'Y: F - -,, Wounded Warrior Trailer Site Prep 05110084 MCB Camp Lejeune, North Carolina CONTRACT N40085-11-B-0084 NAVFAC SPECIFICATION NO. 05-11-0084 WOUNDED WARRIOR TRAILER SITE PREP AT THE MARINE CORPS BASE, CAMP LEJEUNE, NORTH CAROLINA DESIGN BY: C. ALLAN BAMFORTH, JR., ENGINEER -SURVEYOR, LTD. Norfolk, Virginia A/E Contract: N40085-09-D-5335 SPECIFICATION PREPARED BY: Anna Lee Bamforth, P.E., L.S. Date: May 27, 2011 SPECIFICATION APPROVED BY: B. R. Marshburn, P.E., Director Design Branch, Public Works Division C for Commander, Naval FaciC litiesEngineering vCommand ,����e.�"1.CARO�J'% ' O �� �,�ESSj�.�y�/ � � SEAS = 029641 = • Ob�Ob/�1 _— _T-i i9• JUN 1 3 2011 SECTION COVER Page 1 �ii� /FEIBPFOr� Wounded Warrior Trailer Site Prep 05110084 MCB Camp Lejeune, North Carolina SECTION 01 57 13.00 22 EROSION AND SEDIMENT CONTROL 03/09 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only. ASTM INTERNATIONAL (ASTM) ASTM D 3787 (2007) Bursting Strength of Textiles - Constant -Rate -of -Traverse (CRT), Ball Burst Test ASTM D 4533 (2004; R 2009) Trapezoid Tearing Strength of Geotextiles ASTM D 4632 (2008) Grab Breaking Load and Elongation of Geotextiles NORTH CAROLINA SEDIMENT CONTROL COMMISSION (NCSCC) NCSCC ESCM (1993) Erosion and Sediment Control Planning and Design Manual 1.2 DESCRIPTION OF WORK The work includes the provision of temporary and permanent erosion control measures to prevent the pollution of air, water, and land within the project limits and in areas outside the project limits where work is accomplished in conjunction with the project. 1.3 SUBMITTALS Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-01 Preconstruction Submittals Construction Sequence Schedule; G SD-03 Product Data Sediment/Silt Fence Dust Suppressors Filter Fabric 1.4 CONSTRUCTION SEQUENCE SCHEDULE Submit a Contractor furnished construction work sequence schedule, a minimum of 30 days prior to start of construction. The work schedule shall SECTION 01 57 13.00 22 Page 1 JUN 1 3 2011 Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina 05110084 coordinate the timing of land disturbing activities with the provision of erosion control measures to reduce on site erosion and off site sedimentation. Installation of temporary erosion control features shall be coordinated with the construction of permanent erosion control features to assure effective and continuous control of erosion and pollution. 1.5 STATE APPROVED PLAN The erosion control plan indicated has been approved by the State. No additional State review and approval of the erosion control plan is required, unless the Contractor desires to modify the erosion control plan indicated. Should the Contractor desire to modify the State approved plan, a resubmittal to the State, including the State's approval is required prior to the start of construction. The contractor shall be responsible for any additional costs and time incurred as a result of the resubmittal of the previously approved erosion control plan. The contractor shall anticipate a minimum 45 day review period by the State. Provide and maintain erosion control measures in accordance with NCSCC ESCM, and as specified herein. PART 2 PRODUCTS 2.1 SEDIMENT/SILT FENCE 2.1.1 State Standard Sediment/Silt Fence NCSCC ESCM Standard 6.62, sediment/silt fence (maximum height of 18 inches). 2.2 INLET PROTECTION 2.2.1 State Standard Inlet Protection NCSCC ESCM Standard 6.51. 2.3 CONSTRUCTION ENTRANCE 2.3.1 State Standard Construction Entrance 2.3.1.1 Aggregate NCSCC ESCM, Standard 6.06. 2.3.1.2 Filter Fabric A woven or nonwoven polypropylene, nylon, or polyester containing stabilizers and/or inhibitors to make the fabric resistant to deterioration from ultraviolet, and with the following properties: a. Minimum grab tensile strength (TF 25 41/ASTM D 4632) 180 pounds b. Minimum Puncture (TF 25 #4/ASTM D 3787) 75 psi in the weakest direction C. Apparent Opening Size 40-80 (U.S. Sieve Size) d. Minimum Trapezoidal tear strength (TF 25 #2/ASTM D 4533) 50 pounds SECTION O1 57 13.00 22 Page 2 Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina 2.4 DUST SUPPRESSORS 05110084 Calcium chloride, or other standard manufacturer's spray on adhesives designed for dust suppression. 2.5 TEMPORARY SEEDING 2.5.1 State Standard Temporary Seeding Provide seed, lime, fertilizer, and mulch in accordance with NCSCC ESCM, Standards 6.10 and 6.14. Provide straw mulch. PART 3 EXECUTION 3.1 CONSTRUCTION SEQUENCE SCHEDULE Stabilize areas for construction access immediately with gravel. Provide sediment/silt fences as work progresses. Stabilize graded and disturbed areas immediately after grading. Permanent stabilization shall be provided immediately on areas that have been final graded. Temporary seeding and mulching shall be provided on disturbed areas as specified in the paragraph entitled "Temporary Seeding." Installation of temporary erosion control features shall be coordinated with the construction of permanent erosion control features to assure effective and continuous control of erosion and sediment deposition. Remove temporary erosion control measures at the end of construction and provide permanent seeding. 3.2 SEDIMENT/SILT FENCES Install posts at the spacing indicated, and at an angle between 2 degrees and 20 degrees towards the potential silt load area. Sediment/silt fence height shall be approximately 18 inches. Do not attach filter fabric to existing trees. Secure filter fabric to the post and wire fabric using staples, tie wire, or hog rings. Imbed the filter fabric into the ground as indicated. Splice filter fabric at support pole using a 6 inch overlap and securely seal. 3.3 INLET PROTECTION Provide as indicated; drive steel posts evenly spaced around the perimeter of the inlet, a maximum of 4 feet apart. Posts shall be driven immediately adjacent to the drainage structure, a minimum of 24 inches into the ground. The hardware cloth shall be securely fastened to the outside of the posts, with the bottom flap of wire mesh placed under the gravel for anchoring. 3.4 CONSTRUCTION ENTRANCE Provide as indicated, a minimum of 6 inches thick, at points of vehicular ingress and egress on the construction site. Construction entrances shall be cleared and grubbed, and then excavated a minimum of 3 inches prior to placement of the filter fabric and aggregate. The aggregate shall be placed in a manner that will prevent damage and movement of the fabric. Place fabric in one piece, where possible. Overlap fabric joints a minimum of 12 inches. 3.5 DUST SUPPRESSORS �y� ,Immediately dampen the �J�. �V .i-, A JUN 13 2011 BY: surface before calcium chloride application. Apply SECTION 01 57 13.00 22 Page 3 Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina 05110084 dust suppressors on unsurfaced base, subbase and other unsurfaced travel ways. Apply calcium chloride at the rate of 1.0 to 1.25 pounds per square yard of surface for pellets for the initial application. For subsequent applications of calcium chloride, application rates may be approximately 75 percent of initial application rates. Do not apply when raining or the moisture conditions exceed that required for proper application. Apply other dust suppressors in accordance with manufacturers instructions. Protect treated surfaces from traffic for a minimum of 2 hours after treatment. Repeat application of dust suppressors as required to control dust emissions. 3.6 TEMPORARY SEEDING 3.6.1 Time Restrictions Within 48 hours after attaining the grading increment specified herein, provide seed, fertilizer, mulch and water on graded areas when any of the following conditions occur: a. Grading operations stop for an anticipated duration of 30 days or more. b. When it is impossible or impractical to bring an area to finish grade so that permanent seeding operations can be performed without serious disturbance from additional grading. C. Grading operations for a specific area are completed and the seeding seasons specified for permanent seeding are more than 30 days away. d. When an immediate cover is required to minimize erosion, or when erosion has occurred. e. Provide on erosion control devices constructed using soil materials. 3.6.2 Seeding Requirements 3.6.2.1 State Standard Seeding Requirements Provide seed, lime, fertilizer, and mulch in accordance with NCSCC ESCM, Standards 6.10 and 6.14. Provide straw mulch in an air dried condition, and secure mulch in place. 3.6.2.2 Permanent Seeding Temporary seeding shall be removed, and permanent seeding shall be provided during the specified planting season. Provide seed, lime, fertilizer, and mulch in accordance with NCSCC ESCM, Standards 6.11 and 6.14. Provide seeding of Centipedegrass per Table 6.11s, Seeding No. 4CP. 3.7 MAINTENANCE AND INSPECTION Inspect erosion control devices after each rainfall and daily during pro longed rainfall. Remove sediment deposits after each rainfall or when sediment reaches approximately one-half the barrier height. Immediately repair damaged erosion control devices and damaged areas around and underneath the devices. Maintain erosion control devices to assure continued performance of their intended function. Modify the erosion SECTION O1 57 13.00 22 Page 4 Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina 05110084 control plan as required to control problem areas noticed after each inspection. Modifications shall be approved by the Contracting Officer. 3.8 CLEAN UP At the completion of the job, or when directed or approved by the Contracting Officer, temporary erosion control devices shall be removed. Erosion control devices and areas immediately adjacent to the device shall be filled (where applicable), shaped to drain and to blend into the surrounding contours, and provided with permanent seeding. Erosion control devices may remain in place after job completion when approved by the Contracting Officer. -- End of Section -- :: "IED SECTION 01 57 13.00 22 Page 5 JUN 1 3 2011 1 i-cr. Wounded Warrior Trailer Site Prep 05110084 MCB Camp Lejeune, North Carolina SECTION 33 40 00 STORM DRAINAGE UTILITIES 02/10 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO) AASHTO M 198 (2010) Standard Specification for Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants AMERICAN CONCRETE PIPE ASSOCIATION (ACPA) ACPA 01-102 (2000) Concrete Pipe Handbook ACPA 01-103 (2000) Concrete Pipe Installation Manual ASTM INTERNATIONAL.(ASTM) ASTM C 231 (2010) Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method ASTM C 478 (2009) Standard Specification for Precast Reinforced Concrete Manhole Sections ASTM C 76 (2010a) Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe ASTM C 923 (2008) Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures, Pipes and Laterals ASTM C 990 (2009) Standard Specification for Joints for Concrete Pipe, Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants ASTM D 1751 (2004; R 2008) Standard Specification for Preformed Expansion Joint Filler for Concrete Paving and Structural Construction (Nonextruding and Resilient Bituminous Types) ASTM D 1752 (2004a; R 2008) Standard Specifi cation for SECTION 33 40 00 Page 1 3 Wounded Warrior Trailer Site Prep 05110084 MCB Camp Lejeune, North Carolina Preformed Sponge Rubber Cork and Recycled PVC Expansion U.S. GENERAL SERVICES ADMINISTRATION (GSA) FS A-A-60005 (Basic) Frames.Covers, Gratings, Steps, Sump and Catch Basin, Manhole 1.2 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-03 Product Data Placing Pipe Printed copies of the manufacture's recommendations for installation procedures of the materials being placed, prior to installation. 1.3 DELIVERY, STORAGE, AND HANDLING 1.3.1 Delivery and Storage Materials delivered to site shall be inspected for damage, unloaded, and stored with a minimum of handling. Materials shall not be stored directly on the ground. The inside of pipes and fittings shall be kept free of dirt and debris. Before, during, and after installation, plastic pipe and fittings shall be protected from any environment that would result in damage or deterioration to the material. Keep a copy of the manufacturer's instructions available at the construction site at all times and follow these instructions unless directed otherwise by the Contracting Officer. Solvents, solvent compounds, lubricants, elastomeric gaskets, and any similar materials required to install plastic pipe shall be stored in accordance with the manufacturer's recommendations and shall be discarded if the storage period exceeds the recommended shelf life. Solvents in use shall be discarded when the recommended pot life is exceeded. 1.3.2 Handling Materials shall be handled in a manner that ensures delivery to the trench in sound, undamaged condition. Pipe shall be carried to the trench, not dragged. PART 2 PRODUCTS 2.1 PIPE FOR STORM DRAINS Pipe for storm drains shall be of the sizes indicated and shall conform to the requirements specified. 2.1.1 Concrete Pipe Manufactured in accordance with and conforming to ASTM C 76, Class III and V. SECTION 33 40 00 Page 2 Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina 2.1.1.1 Joint Sealants 05110084 Provide primers and lubricants as recommended by the manufacturer. Concrete pipe joints shall be suitable for use with the joint sealants specified. a. Butyl gaskets. b. AASHTO M 198, Type B preformed plastic gaskets. 2.2 DRAINAGE STRUCTURES 2.2.1 Flared End Sections Sections shall be of a standard design fabricated from reinforced concrete.Flared ends are included in the lengths of pipe indicated. 2.3 MISCELLANEOUS MATERIALS 2.3.1 Concrete Unless otherwise specified, concrete and reinforced concrete shall conform to the requirements for 3500 psi concrete under Section 03 30 00 CAST -IN -PLACE CONCRETE. The concrete mixture shall have air content by volume of concrete, based on measurements made immediately after discharge from the mixer, of 5 to 7 percent when maximum size of coarse aggregate exceeds 1-1/2 inches. Air content shall be determined in accordance with ASTM C 231. The concrete covering over steel reinforcing shall not be less than 1 inch thick for covers and not less than 1-1/2 inches thick for walls and flooring. Concrete covering deposited directly against the ground shall have a thickness of at least 3 inches between steel and ground. Expansion -joint filler material shall conform to ASTM D 1751, or ASTM D 1752, or shall be resin -impregnated fiberboard conforming to the physical requirements of ASTM D 1752. 2.3.2 Precast Reinforced Concrete Drainage Structures Conform to ASTM C 478. Joints between precast concrete risers and tops shall be rubber -type gaskets meeting the requirements of ASTM C 990 or AASHTO M 198, Type B gaskets. 2.3.3 Frame and Cover for Gratings FS A-A-60005 Cast iron, figure numbers as indicated. 2.4 RESILIENT CONNECTORS Flexible, watertight connectors used for connecting pipe to manholes and inlets shall conform to ASTM C 923. PART 3 EXECUTION 3.1 EXCAVATION FOR STORM DRAINS AND DRAINAGE STRUCTURES Excavation of trenches, and for appurtenances and backfilling for culverts and storm drains, shall be in accordance with the applicable portions of Section 31 23 00.00 20, EXCAVATION AND FILL and the requirements specified below. T T2 Y71 /\ T'� T'V �� 1 SECTION 33 40 00 Page 3 JUN 33 2011 �1i v: Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina 3.1.1 Trenching 05110084 The width of trenches at any point below the top of the pipe shall be not greater than indicated to permit satisfactory jointing and thorough tamping of the bedding material under and around the pipe. Sheeting and bracing, where required, shall be placed within the trench width as specified, without any overexcavation. Where trench widths are exceeded, redesign with a resultant increase in cost of stronger pipe or special installation procedures will be necessary. Cost of this redesign and increased cost of pipe or installation shall be borne by the Contractor without additional cost to the Government. 3.1.2 Removal of Unstable Material Where wet or otherwise unstable soil incapable of properly supporting the pipe, as determined by the Contracting Officer, is unexpectedly encountered in the bottom of a trench, such material shall be removed to the depth required and replaced to the proper grade with select granular material, compacted as provided in paragraph BACKFILLING. When removal of unstable material is due to the fault or neglect of the Contractor while performing shoring and sheeting, water removal, or other specified requirements, such removal and replacement shall be performed at no additional cost to the Government. 3.2 BEDDING The bedding surface for the pipe shall provide a firm foundation of uniform density throughout the entire length of the pipe. 3.2.1 Concrete Pipe Requirements When no bedding class is specified or detailed on the drawings, concrete pipe shall be bedded in granular material minimum 4 inch in depth in trenches with soil foundation. Depth of granular bedding in trenches with rock foundation shall be 1/2 inch in depth per foot of depth of fill, minimum depth of bedding shall be 8 inch up to maximum depth of 24 inches. The middle third of the granular bedding shall be loosely placed. Bell holes and depressions for joints shall be removed and formed so entire barrel of pipe is uniformly supported. The bell hole and depressions for the joints shall be not more than the length, depth, and width required for properly making the particular type of joint. 3.3 PLACING PIPE Submit printed copies of the manufacturer's recommendations for installation procedures of the material being placed, prior to installation. Each pipe shall be thoroughly examined before being laid; defective or damaged pipe shall not be used. Plastic pipe shall be protected from exposure to direct sunlight prior to laying, if necessary to maintain adequate pipe stiffness and meet installation deflection requirements. Pipelines shall be laid to the grades and alignment indicated. Proper facilities shall be provided for lowering sections of pipe into trenches. Pipe shall not be laid in water, and pipe shall not be laid when trench conditions or weather are unsuitable for such work. Diversion of drainage or dewatering of trenches during construction shall be provided as necessary. SECTION 33 40 00 Page 4 Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina 3.3.1 Concrete Pipe 05110084 Laying shall proceed upgrade with spigot ends of bell -and -spigot pipe and tongue ends of tongue -and -groove pipe pointing in the direction of the flow. 3.4 JOINTING 3.4.1 Concrete Pipe 3.4.1.1 Flexible Joints Install pipe and fittings in accordance with paragraph entitled "General Requirements for Installation of Pipelines" of this section and with the provisions for rugger gasket jointing and jointing procedures of ACPA 01-103 or of ACPA 01-102, Chapter 9. Make joints with the gaskets previously specified for joints with this piping. Gaskets and jointing materials shall be as recommended by the particular manufacturer in regard to use of lubricants, cements, adhesives, and other special installation requirements. Surfaces to receive lubricants, cements, or adhesives shall be clean and dry. Gaskets and jointing materials shall be affixed to the pipe not more than 24 hours prior to the installation of the pipe, and shall be protected from the sun, blowing dust, and other deleterious agents at all times. Gaskets and jointing materials shall be inspected before installing the pipe; any loose or improperly affixed gaskets and jointing materials shall be removed and replaced. The pipe shall be aligned with the previously installed pipe, and the joint pushed home. If, while the joint is being made the gasket becomes visibly dislocated the pipe shall be removed and the joint remade. 3.5 DRAINAGE STRUCTURES 3.5.1 Manholes and Inlets Construction shall be of reinforced concrete, plain concrete, or precast reinforced concrete; complete with frames and covers or gratings. Pipe connections to concrete manholes and inlets shall be made with flexible, watertight connectors. 3.5.2 Walls and Headwalls Construction shall be as indicated. 3.6 BACKFILLING Perform earthwork operations in accordance with Section 31 23 00.00 20, EXCAVATION AND FILL. 3.6.1 Movement of Construction Machinery when compacting by rolling or operating heavy equipment parallel with the pipe, displacement of or injury to the pipe shall be avoided. Movement of construction machinery over a culvert or storm drain at any stage of construction shall be at the Contractor's risk. Any damaged pipe shall be repaired or replaced. SECTION 33 40 00 Page 5 RFC'�-�.ZVED, JUN 1 3 2011 f BY: Wounded Warrior Trailer Site Prep MCE Camp Lejeune, North Carolina 3.7 PIPELINE TESTING 3.7.1 Field Tests and Inspections 05110084 The Contracting Officer will conduct field inspections and witness field tests specified in this section. The Contractor shall perform field tests and provide labor, equipment, and incidentals required for testing. Be able to produce evidence, when required, that each item of work has been constructed properly in accordance with the drawings and specifications. 3.7.2 Pipeline Testing Check each straight run of pipeline for gross deficiencies by holding a light in a manhole; it shall show a practically full circle of light through the pipeline when viewed from the adjoining end of line. -- End of Section -- SECTION 33 40 00 Page 6 REPORT OF SUBSURFACE INVESTIGATION AND GEOTECHNICAL ENGINEERING SERVICES Project 110084 Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina G E T PROJECT NO: JX11-104G April 26, 2011 Prepared for C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd 2207 Hampton Boulevard Norfolk, Virginia 23517 ATTN: Mrs. Anna Lee Bamforth, P.E. Prepared by GET Solutions, Inc. JUN 1 3 2011 415 A Western Boulevard, Jacksonville, NC 28546 ♦ Phone 910-478-9915 ♦ Fax 910-418-9917 info@getsolutionsinc.com $O�Ua0I15G� _ Cm.Ov! rN - .vroai - lisrirtc TO: C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd 2207 Hampton Boulevard Norfolk, Virginia 23517 Attn: Mrs. Anna Lee Bamforth, P.E. RE: Report of Subsurface Investigation and Geotechnical Project 110084-Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina G E T Project No: JX11-104G Dear Mrs. Bamforth: April 26, 2011 Engineering Services In compliance with your instructions, we have completed our Geotechnical Engineering Services for the referenced project. The results of this study, together with our recommendations, are presented in this report. Often, because of design and construction details that occur on a project, questions arise concerning subsurface conditions. G E T Solutions, Inc. would be pleased to continue its role as Geotechnical Engineer during the project implementation. We trust that the information contained herein meets your immediate need, and we would ask that you call this office with any questions that you may have. Respectfully Submitted, """ q" ", G E T Solutions, Inc. ,�peEs a�*y9•; G(/• /y? 4 PE No. 033529 Glenn W. Hohmeier, P.E. iik1 �IGINE�P �<v{ Senior Project Engineer K' µC NC Reg. # 033529 „rrr, Camille A. Kattan, P.E. Principal Engineer = SEAL NC Reg. # 014103 = 014103 9� tee. f ryc. i..E.. .�. 415-A Western Boulevard • Jacksonville, NC 28546 • Phone: (910) 478-9915 • Fax: (910) 478-9917 info@getsolutionsinc.com TABLE OF CONTENTS 1.0 PROJECT INFORMATION..............................................................................1 1.1 Project Authorization..............................................................................1 1.2 Project Location and Site Description....................................................1 1.3 Purpose and Scope...............................................................................1 2.0 FIELD AND LABORATORY PROCEDURES..................................................2 2.1 Field Exploration....................................................................................2 2.2 Laboratory Testing.................................................................................2 3.0 SITE AND SUBSURFACE CONDITIONS........................................................3 3.1 Site Geology..........................................................................................3 3.2 Subsurface Soil Conditions....................................................................3 3.3 Groundwater Information.......................................................................4 4.0 EVALUATION AND RECOMMENDATIONS...................................................5 4.1 Soil Permeability....................................................................................5 4.2 Structural Fill and Placement.................................................................6 4.3 Suitability of On -site Soils......................................................................6 5.0 CONSTRUCTION CONSIDERATIONS...........................................................7 5.1 Drainage and Groundwater Concerns...................................................7 5.2 Site Utility Installation.............................................................................7 5.3 Excavations...........................................................................................8 6.0 REPORT LIMITATIONS...................................................................................9 APPENDIX I BORING LOCATION PLAN APPENDIX II BORING LOGS APPENDIX III GENERALIZED SOIL PROFILE APPENDIX IV HYDRAULIC CONDUCTIVITY WORKSHEETS APPENDIX V CLASSIFICATION SYSTEM FOR SOIL EXPLORATION JUN 1 3 2011 Report of Subsurface Investigation and Geotechnical Engineering Services Apt 26, 2011 Project 110084-Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina GET Project No: JX11-104G 1.0 PROJECT INFORMATION 1.1 Project Authorization G E T Solutions, Inc. has completed our Geotechnical Engineering study for the proposed Project 110084-Wounded Warrior Trailer Site Prep Project located within the Marine Corps Base (MCB) Camp Lejeune, North Carolina. The geotechnical engineering services were conducted in general accordance with the scope presented in GET Proposal No. PJX11- 102G. Authorization to proceed with our subsurface investigation and geotechnical engineering services was received from Mrs. Anna Lee Bamforth of C. Allan Bamforth; Jr., Engineer -Surveyor, Ltd. 1.2 Project Location and Site Description The project site is located within the Wounded Warrior Complex of MCB Camp Lejeune, North Carolina. The construction at this site is planned to consist of installing eight (8) double wide trailers and a storm water management facility. The site is located within a partially wooded tract and partially open area of land near the west center portion of the Wounded Warrior Complex. The project site slopes from east to west with existing grades ranging from approximately 19 feet (MSL) along the east perimeter to about 17 feet (MSL) along the western side. The site is bordered to the north and east by the Wounded Warrior Complex currently under construction, to the south and west by vacant parcels of land. 1.3 Purpose and Scope of Services: The purpose of this study was to obtain information on the general subsurface conditions at the proposed project site. The subsurface.conditions encountered were then evaluated with respect to the available project characteristics. In this regard, engineering assessments for the following items were formulated: General assessment of the soils revealed by the borings performed at the proposed development. 2. General location and description of potentially deleterious material encountered in the borings that may interfere with construction progress or performance, including existing fills, surficial/subsurface organics, or expansive soils. Soil preparation and construction considerations including grading, and compaction, as well as providing Engineering criteria for placement and compaction. of approved structural fill material, including weather and equipment effects. S6luti6hs,4 c&7M Report of Subsurface Investigation and Geotechnical Engineering Services April26, 2011 Project 110084-Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina GET Project No: JX11-104G 4. Permeability (infiltration) values are provided based on the results of in -situ Saturated Hydraulic Conductivity Testing as well as our experience with similar soil conditions. Seasonal high groundwater table (SHWT) was also estimated. The scope of services did not include an environmental assessment for determining the presence or absence of wetlands or hazardous or toxic material in the soil, bedrock, surface water, groundwater or air, on or below or around this site. Any statements in this report or on the boring logs regarding odors, color, unusual or suspicious items or conditions are strictly for the information of the client. Prior to development of this site, an environmental assessment is advisable. 2.0 FIELD AND LABORATORY PROCEDURES 2.1 Field Exploration In order to explore the general nature and composition of the subsurface soils at this site, a total of two (2)10-foot deep hand auger borings (designated as PT-1 and PT-2) were drilled by G E T Solutions, Inc. within the limits of the proposed storm water management basin area. In addition, to aid in developing associated storm water management parameters, two (2) additional hand auger borings were advanced in the immediate vicinity of PT-1 and PT-2 and two (2) saturated hydraulic conductivity tests (in -situ) were completed within the proposed storm water management area. A representative portion of each disturbed hand auger sample was collected, placed in a ziplock bag, sealed, labeled, and returned to our laboratory for review. The boring locations were established and staked in the field by a representative of G E T Solutions, Inc. with the use of a Global Positions System unit as well as the "State Plane" coordinates selected from the project site plan. The approximate boring locations are shown on the attached "Boring Location Plan" (Appendix 1), which was reproduced based on the site plan provided by C. Allan Bamforth, Jr., Engineer -Surveyor, Ltd. 2.2 Laboratory Testing Representative portions of all soil samples collected during drilling were sealed in ziplock bags, labeled and transferred to our laboratory for classification and analysis. The soil classification was performed by a Geotechnical Engineer in accordance with ASTM D2488. Two (2) representative soil samples were selected and subjected to laboratory testing, which included natural moisture and 4200 sieve wash and atterberg limits testing and analysis, in order to corroborate the visual classification. These test results are provided in the following table (Table I — Laboratory Test Results) and are presented on the 'Boring Log" sheets (Appendix 11), included with this report. _ 4� 4 ( VED 2 JUN 1 3 2011 GET Report of Subsurface Investigation and Geotechnical Engineering Services April 26,2011 Project 110084-Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina GET Project No: JX11-104G Table I - Laboratory Test Results Boring Sample Depth Natural % Atterberg USCS No.; Type (Feet) Moisture Passing Limits Classificatio #200 LL/PL/PI N PT-1 Hand Auger 1.5-2 11.4 12.9 Non -Plastic SM PT-2 Hand Au er 1.5-2 10.4 13.1 Non -Plastic SM 3.0 SITE AND SUBSURFACE CONDITIONS 3.1 Site Geology The project site lies within a major physiographic province called the Atlantic Coastal Plain. Numerous transgressions and regressions of the Atlantic Ocean have deposited marine, lagoonal, and fluvial (stream lain) sediments. The regional geology is very complex, and generally consists of interbedded layers of varying mixtures of sands, silts and clays. Based on our review of existing geologic and soil boring data, the geologic stratigraphy encountered in our subsurface explorations generally consisted of marine deposited sands, silts and clays. 3.2 Subsurface Soil Conditions: The results of our field exploration program indicated the presence of 3 to 6 inches of topsoil at the soil boring locations. Beneath the surficial topsoil, the natural subsurface soils were generally arranged in a 2-layer configuration. The initial natural soil layer extended to a depth of approximately 6 feet below existing grades and was noted to be primarily granular in nature consisting of SAND (SM and SC) with varying amounts of silt and/or clay. The final soil layer extended to boring termination depth of approximate 10 feet below existing site grades and was noted to consist of Sandy Lean CLAY (CL) with varying amounts of sand. The subsurface description is of a generalized nature provided to highlight the major soil strata encountered. The records of the subsurface exploration are included on the `Boring Log" sheets (Appendix II) and in the "Generalized Soil Profile" (Appendix III), which should be reviewed for specific information as to the individual borings. The stratifications shown on the records of the subsurface exploration represent the conditions only at the actual boring locations. Variations may occur and should be expected between boring locations. The stratifications represent the approximate boundary between subsurface materials and the transition may be gradual or occur between sample intervals. It is noted that the topsoil designation references the presence of surficial organic laden soil, and does not represent any particular quality specification. This material is to be tested for approval prior to use. Solutions ?Inc Report of Subsurface Investigation and Geotechnical Engineering Services Ap0126, 2011 Project 110084-Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina GET Project No: JX11-104G 3.3 Groundwater Information: Groundwater was not encountered at boring PT-1 and PT-2 locations at the time of drilling to depths explored. In addition, two (2) temporary piezometers were installed at the boring PT-1 and PT-2 locations at the time of drilling and 24 hour groundwater readings were taken. The 24 hour groundwater readings did not detect any groundwater in the temporary piezometers installed in the open bore holes at PT-1 and PT-2 (depths of 10-feet below existing site grades). The piezometers were removed following the 24-hour readings and the boreholes were backfilled. Also, the soils recovered from boring PT-1 and PT-2 locations were visually classified to identify color changes to aid in indicating the normal estimated Seasonal High Water Table (SHWT). It is noted that soil morphology may not be a reliable indicator of the SHWT. However, color distinctions (from tan to orangish brown and gray) were observed within the soil profile of soil samples collected at the location of borings PT-1 and PT-4. As such, the normal SHWT depth was estimated to occur at approximately 3.5 feet below the existing site grades at each of these borings. Groundwater conditions will vary with environmental variations and seasonal conditions, such as the frequency and magnitude of rainfall patterns, as well as man-made influences, such as existing swales, drainage ponds, underdrains and areas of covered soil (paved parking lots, sidewalks, etc.). Seasonal groundwater fluctuations of±2 feet are common in the project's area; however, greater fluctuations have been documented. We recommend that the contractor determine the actual groundwater levels at the time of the construction to determine groundwater impact on the construction procedures. .71T.,V ZD JUN 1 3 2011 ISO] UU ru.'!bviroAt Report of Subsurface Investigation and Geotechnical Engineering Services April 26,2011 Project 110084-Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina GET Project No: JX11-104G 4.0 EVALUATION AND RECOMMENDATIONS Our recommendations are based on previously discussed project information, our interpretation of the soil test borings and laboratory data, and our observations during our site reconnaissance. If the proposed construction should vary from what was described, we request the opportunity to review our recommendations and make any necessary changes. 4.1 Soil Permeability Two (2) infiltration test boreholes were prepared (boring locations PT-1 and PT-2) utilizing a planer auger to remove soil clippings from their base. Infiltration testing was performed at a depth corresponding to an elevation of approximately 1.5 to 2.0 feet below the existing site grades at each of the boring locations. Infiltration test depths at each of the boring locations were determined based on the estimated SHWT of about 3.5 feet below existing site grades. Please refer to Section 3.3 of this report for additional groundwater information. Infiltration testing was then conducted within the vadose zone utilizing a Precision Permeameter and the following testing procedures. A support stand was assembled and placed adjacent to the borehole. This stand holds a calibrated reservoir (2000 ml) and a cable used to raise and lower the water control unit (WCU). The WCU establishes a constant water head within the borehole during testing by use of a precision valve and float assembly. The WCU was attached to the flow reservoir with a 2-meter (6.6 foot) braided PVC hose and then lowered by cable into the borehole to the test depth elevation. As required by the Glover solution, the WCU was suspended above the bottom of the borehole at an elevation of approximately 5 times the borehole diameter. The shut-off valve was then opened allowing water to pass through the WCU to fill the borehole to the constant water level elevation. The absorption rate slowed as the soil voids became filled and an equilibrium developed as a wetting bulb developed around the borehole. Water was continuously added until the flow rate stabilized. The reservoir was then re -filled in order to begin testing. During testing, as the water drained into the borehole and surrounding soils, the water level within the calibrated reservoir was recorded as well as the elapsed time during each interval. The test was continued until relatively consistent flow rates were documented. During testing the quick release connections and shutoff valve were monitored to ensure that no leakage occurred. The flow rate (Q), height of the constant water level (H), and borehole diameter (D) were used to calculate Ks utilizing the Glover Solution. 14M AV Solutlor g b Report of Subsurface Investigation and Geotechnical Engineering Services Project 110084-Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina GET Project No: JX11-104G April 26, 2011 Based on the field testing and corroborated with laboratory testing results (published values compared to classification results), the hydraulic conductivity of the shallow soils is tabulated below (Table III) and is presented on the "Hydraulic Conductivity Worksheet" (Appendix IV), included with this report. Table III — Infiltration Test Results Infiltration Test Test Depth r#200 Sieve Classification H �O nductrvity cm/sec in/hour . ' .' /sec" PT-1 1.5 to 2 12.9 SM 3.621 2.55E-03 PT-2 1.5 to 2 13.1 SM 1.691 1.19E-03 4.2 Structural Fill and Placement Any material to be used for backfill or structural fill should be evaluated and tested by G E T Solutions, Inc. prior to placement to determine if they are suitable for the intended use. Suitable structural fill material should consist of sand or gravel containing less than 20 percent by weight of fines (SP, SP-SM, SM, SW, SW-SM, GP, GP -GM, GW, GW-GM), having a liquid limit less than 20 and plastic limit less than 6, and should be free of rubble, organics, clay, debris and other unsuitable material. All structural fill should be compacted to a dry density of at least 95 percent of the Modified Proctor maximum dry density (ASTM D1557). In general, the compaction should be accomplished by placing the fill in maximum 10-inch loose lifts and mechanically compacting each lift to at least the specified minimum dry density. A representative of G E T Solutions, Inc. should perform field density tests on each lift as necessary to assure that adequate compaction is achieved. 4.3 Suitability of On -site Soils Based on the laboratory testing program, the shallow subsurface SAND (SM) .soils encountered at the boring locations (beneath the topsoil) appear to meet the criteria recommended in this reportfor reuse as structural fill. Additionally, it is anticipated that any soils excavated on -site and proposed to be re -used as backfill, will require stockpiling and air drying in order to establish a moisture content suitable for compaction. Soil deposits excavated at the site and noted to contain significant amounts of organics should not be used as fill and/or backfill within the proposed construction areas. Further classification testing (natural moisture content, gradation analysis, and Proctor testing) should be performed in the field during construction to evaluate the suitability of excavated soils for reuse as fill and backfill. ZILD JUN 1 3 2011 Soliitiorsi?lnc� - Report of Subsurface Investigation and Geotechnical Engineering Services April 26,2011 Project 110084-Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina GET Project No: JX11-104G Backfill material in utility trenches within the construction areas should consist of structural fill (as described above), and should be compacted to at least 95 percent of ASTM D1557. This fill should be placed in 4 to 6 inch loose lifts when hand compaction equipment is used. 5.0 CONSTRUCTION CONSIDERATIONS 5.1 Drainage and Groundwater Concerns: It is expected that dewatering may be required for excavations that extend near or below the existing groundwater table. Dewatering above the groundwater level could probably be accomplished by pumping from sumps. Dewatering at depths below the groundwater level will likely require well pointing. It is recommended that the contractor determine the actual groundwater levels at the time of the construction to determine groundwater impact throughout the project site and at specific proposed excavation locations. It would be advantageous to construct all fills early in the construction. If this is not accomplished, disturbance of the existing site drainage could result in collection of surface water in some areas, thus rendering these areas wet and very loose. Temporary drainage ditches should be employed by the contractor to accentuate drainage during construction. 5.2 Site Utility Installation: The base of the utility trenches should be observed by a qualified inspector prior to the pipe and structure placement to verify the suitability of the bearing soils. Based on the -results of our field exploration program it is expected that the utilities and structures located at depths greater than about 10 feet below current grades may bear in wet, soft clayey soils. In these instances the bearing soils will likely require some stabilization to provide suitable bedding. This stabilization is typically accomplished by providing additional bedding materials (No. 57 stone). In addition depending on the depth of the utility trench excavation, some means of dewatering may be required to facilitate the utility installation and associated backfilling. Excavations extending below the groundwater level will likely require well pointing. Generally, the subsurface soils encountered at the boring locations appear to meet the criteria recommended in this report for reuse as structural fill. Accordingly, bulk soil sampling and classification testing is recommended to be performed to substantiate the suitability of their intended use at the time of construction. Additionally, stockpiling and allowing the soils to air dry may be required in order to obtain a moisture content suitable for compaction procedures. Solutforjs�Lic Report of Subsurface Investigation and Geotechnical Engineering Services Apr 126, 2011 Project 110084-Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina GET Project No: JX11-104G 5.3 Excavations: In Federal Register, Volume 54, No. 209 (October, 1989), the United States Department of Labor, Occupational Safety and Health Administration (OSHA) amended its "Construction Standards for Excavations, 29 CFR, part 1926, Subpart P". This document was issued to better insure the safety of workmen entering trenches or excavations. It is mandated by this federal regulation that all excavations, whether they be utility trenches, basement excavation or footing excavations, be constructed in accordance with the new (OSHA) guidelines. It is our understanding that these regulations are being strictly enforced and if they are not closely followed, the owner and the contractor could be liable for substantial penalties. The contractor is solely responsible for designing and constructing stable, temporary excavations and should shore, slope, or bench the sides of the excavations as required to maintain stability of both the excavation sides and bottom. The contractor's responsible person, as defined in 29 CFR Part 1926, should evaluate the soil exposed in the excavations as part of the contractor's safety procedures. In no case should slope height, slope inclination, or excavation depth, including utility trench excavation depth, exceed those specified in local, state, and federal safety regulations. We are providing this information solely as a service to our client. G E T Solutions, Inc. is not assuming responsibility for construction site safety or the contractor's activities; such responsibility is not being implied and should not be inferred. I�1C=FTr� 8 JUN 1 3 2011 I LY: GET Report of Subsurface Investigation and Geotechnical Engineering Services April 26,2011 Project 110084-Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina GET Project No: JX11-104G - 6.0 REPORT LIMITATIONS The recommendations submitted are based on the available soil information obtained by G E T Solutions, Inc. and the information supplied by the client for the proposed project.If there are any revisions to the plans for this project or if deviations from the subsurface conditions noted in this report are encountered during construction, G E T Solutions, Inc. should be notified immediately to determine if changes in our recommendations are required. If G E T Solutions, Inc. is not retained to perform these functions, G E T Solutions, Inc. can not be responsible for the impact of those conditions on the geotechnical recommendations for the project. The Geotechnical Engineer warrants that the findings, recommendations, specifications or professional advice contained herein have been made in accordance with generally accepted professional geotechnical engineering practices in the local area. No other warranties are implied or expressed. After the plans and specifications are more complete the Geotechnical Engineer should be provided the opportunity to review the final design plans and specifications to assure our engineering recommendations have been properly incorporated into the design documents, in order that the earthwork recommendations may be properly interpreted and implemented. At that time, it may be necessary to submit supplementary recommendations. This report has been prepared for the exclusive use of the Client and their consultants for the specific application to the proposed Project 110084-Wounded Warrior Trailer Site Prep located within the MCB Camp LeJeune military installation in North Carolina. S I oirs lne - APPENDICES :Z910fEel t.Z�Ilork1 A_1�1 BORING LOGS III GENERALIZED SOIL PROFILE IV HYDRAULIC CONDUCTIVITY WORKSHEETS V CLASSIFICATION SYSTEM FOR SOIL EXPLORATION RECL= JUN 1 3 2011 BY: L ---__ z t�s cc �y4 N o .. N BORING LOCATION PLAN PROJECT: Project 110084-Wounded Warrior Trailer Site Prep MCB Camp Lejeune, North Carolina PROJECT NO: JX11-104G CLIENT: C. Allan Bamforth, Jr. Engineer -Surveyor, LTD V SCALE: As Drawn DATE: 4/25/2011 PLOT BY: GH GET PROJECT: Project 110084-Wounded Warrior Trailer. Site Prep CLIENT: C. Allan Bamforth, Jr. Engineer -Surveyor, LTD �„•.r,.Y•�.r-.�-....,:�.r�y BORING LOG PT-1 PROJECT LOCATION: MCB Camp Lejeune, NC PROJECT NO.: JX11-104G BORING LOCATION: See Attached Boring Location Plan SURFACE ELEVATION: 17 DRILLER: GET Solutions,Inc. DRIL ING METHOD RolaryWash Mud Drilling DATE:ED BY: qwh 4 22 DEPTH TO WATER -INITIAL*: �SZ _ AFTER 24 HOURS: _ CAVING> L ,t N W d� o E w v o Description P v a, m r7 v a o° E Z to v E o U N v a v E M I— 3 2 o to a y 2# Z o v TEST RESULTS Plastic Limit H Liquid Limit Moisture Content- • N-Value - 10 20 30 40 50 60 70 — 0 0 HA HA HA HA.. HA 12. 6-inches of Topsoil .5 Tan, moist, Silty fine to medium SAND (SM) � _.........:. ..... ..... ...:...:...:.. .:...:...:...:... 4..iL Woe JUN 1.3 2011 16 08 14 3.5 Orangish brown and Gray, moist, Silty fine to medium SAND (SM) with trace Clay' Estimated SHWT @ 3.5 feet 1. 12 6 Gray and orangish brown, moist, Clayey fine to medium SAND (SC) � .'. 1 24 Mottled gray-orangish brown, moist, Sandy LEAN CLAY (CL) 8 3.2 10 Boring terminated at 10 ft. 4 — 12 4 14 -- Notes: SS = Split Spoon Sample ST = Shelby Tube Sample HA = Hand Auger Sample BS = Bulk Sample *The initial r m rr in may not be indicative ofth i r r I WOH=W fHammer PAGE 1 of 1 Standard Penetration Tests were performed in the field in general accordance with ASTM D 1586, GET PROJECT: Project 110084-Wounded Warrior Trailer Site Prep CLIENT: C. Allan Bamforth Jr. Engineer -Surveyor LTD PROJECT LOCATION: MCB Camp Lejeune, NC PROJECT NO.: JX11-104G BORING LOCATION: See Attached Boring Location Plan SURFACE ELEVATION: 17.5 BORING LOG DRILLER: GET Solutions, Inc. LOGGED BY: 9wh DRILLING METHOD: Rotary Wash Mud Drilling DATE: 4-22-11 PT-2 DEPTH TO WATER - INITIAL": $ AFTER 24 HOURS: T- CAVING> L o r V ,� t w m oo TEST RESULTS L y= N m m m m Description E Z E E Plastic Limit H Liquid Limit W� 0 E rn W t- m cu z v Moisture Content - • N-Value - Tan, moist, Silty fine to medium SAND (SM) Orangish brown and Gray, moist, Silty fine to medium SAND (SM) with trace Clay Estimated SHWT @ 3.5 feet Gray and orangish brown, moist, Clayey fine to medium SAND Mottled gray-orangish brown, moist, Sandy LEAN CLAY (CL) at 10 Notes HA HAI III HA I I h : . . SS = Split Spoon', ST = Shelby Tube HA = Hand Auger BS = Bulk Sample wnu = mr.-H, -1 I PAGE 1 of 1 Standard Penetration Tests were performed in the field in general accordance with ASTM D 1586, APPENDIX III GENERALIZED SOIL PROFILE JUN 1 3 2011 18 IB PT 16 16 -N0.A�fifd NM-IIA 14 J 12 f3 Y O mT Y Is 10 B a 6 6 Strata symbols Topsoil Silly Sand GET Solutions, Inc. GENERALIZED SOIL PROFILE � Clayey Sand HORIZONTAL SCALE DRAWN BY/APPROVED BY DATE DRAWN VFA �LJV,A I MAIL SCALE: 1.=2' 0h 412612011 ® Lean clay Project 1 10084-Wounded Warrior Trailer Site Prep FIGURE NUMBER PRO.IGC"1' NO. Jtl 1-104G APPENDIX IV HYDRAULIC CONDUCTIVITY WORKSHEETS 77 W LD JUN 1 8 2011 G E T Solutions, Inc. SATURATED HYDRAULIC CONDUCTIVITY WORKSHEET Sheet No.: 1 of 1 Project Name.: Project 110084 Wounded Warrior Trailer Site Prep Location.......: MCB Camp Lejeune Terminology and Solution Boring No......: PT-1 Date .............: 4/25/2011 Ksat : Saturated hydraulic conductivity Investigators.: M. Guzman File No.........: JX11-104G Q: Steady-state rate of water flow into the soil Boring Depth.: 2 ft WCU Base. Ht. h: 15.0 cm H: Constant height of water in borehole Boring Dia..... : 8.3 cm WCU Susp. Ht. S: 15.2 cm r: Radius of cylindrical borehole Boring Rad. (r): 4.15• cm VOLUME Volume Out TIME ml ml a hr:min:sela/p) Const. Wtr. Ht. H: 30.2 cm Ela sed Time Flow Rate Q hr:min:sec min b mllmin alb Ksal = Qlsinh-1 (H/r) - (r2/H2+1).5 + r/H) / (2pH2) [Glover Solution] ------------------- Ksat Equivalent Values------------------ cmisec cm/da inlhr fUdayl 3200-= 12:45: ' _ .' . "-�i:`', 3100 100 12:45:1 0:00:13 0.22 - 461.54 0.146 2.43E-03 210.0 3.445 6.89 3000 100 12:45: 0:00:12 0.20 500.00 0.158 2.63E-03 227.5 3.732 7.46 2900 100 12:45: 0:00:13 0.22 461.54 0.146 2.43E-03 210.0 3.445 6.89 2800 100 12:45:50 PM 0:00:12 0.20 500.00 0.158 2.63E-03 227.5 3.732 7.46 2700 100 12:46:01 PM 000: 11 0.18 545.45 0.172 2.87E-03 248.2 4.071 8.14 2600 100 12:46:14 PM 0:00:13 0.22 461.54 0.146 2.43E-03 210.0 3.445 6.89 2500 100 12:46:27 PM 00013 0.22 461.54 0.146 2.43E-03 210.0 3.445 6.89 2400 100 12:46:39 PM 0:00*12 0.20 500.00 0.158 2.63E-03 227.5 3.732 7.46 2300 100 12:46:52 PM 0:00:13 0.22 461.54 0.146 2.43E-03 210.0 3.445 6.89 2200 100 12:47:03 PM 0:00: 11 0.18 545.45 0.172 2.87E-03 248.2 4.071 8.14 2100 100 12:47:16 PM 0:00:13 0.22 461.54 0.146 2.43E-03 210.0 3.445 6.89 2000 100 12:47:29 PM 0:00:13 0.22 461.54 0.146 2.43E-03 210.0 3.445 6.89 Natural Moisture: 11.4% USCS Class.: SM % Passing. #200 : 12.9% Consistency: Very loose to loose ESTIMATED FIELD KSAT: 0.153 Depth to an Impermeable Layer: NA 2.55E-03 220.7 3.6211 7.24 Notes: Ksat Class =High StructurelFabric: NA Slo a/Landsc: p .NA Depth [o Bedrock ...................: NA Precision Permeametei'° G E T Solutions, Inc. SATURATED HYDRAULIC CONDUCTIVITY WORKSHEET Sheet No.: 1 of 1 Project Name.: Project 110084 Wounded Warrior Trailer Site Prep Location.......: MCB Camp Le'eune - Terminology and Solution Boring No......: PT-2 Date .............: 4/25/2011 Ksat : Saturated hydraulic conductivity Investigators.: M. Guzman File No.........: JX11-104G Q: Steady-state rate of water Flow into the soil Boring Depth.: 2 ft WCU Base. Ht. h: 15.0 cm H: Constant height of water in borehole Boring Dia..... : 8.3 cm WCU Susp. Ht. S: 15.2 cm r: Radius of cylindrical borehole Boring Rad. (r): - 4.15 cm Const. WV. Ht. H: 30.2 cm Ksat = Q[sinh-l(H/r) - (r2/H2+1).5 + r/Hj / (2pH2) [Glover Solution] VOLUME ml Volume Out ml a TIME hr:min:sec al Elapsed Time Flow Rate Q mllmin alb ------------------- Ksat Equivalent Values ------------------ hr:min:sec min b cm/min cmfsec(cm/day) in/hr ft/da 3200 - 12:18:00 PM 3100 100 12:18:26 PM 00026 0.43 230.77 0,073 1.22E-03 105.0 1.722 3.44 3000 100 12:18:49 PM 00023 0.38 260.87 0,082 1.37E-03 118.7 1.947 3.89 2900 100 12:19:14 PM 00025 0.42 240.00 _ 0.076 1.26E-03 109.2 1,791 3.58 2800 100 12:19:40 PM 00026 0.43 230.77 0.073 1.22E-03 105.0 1.722 3.44 2700 100 12:20:05 PM 0:00:25 0.42 240.00 0.076 1.26E-03 109.2 1.791 3.58 2600 100 12:20:33 PM 00028 0.47 214.29 0.068 1.13E-03 97.5 1.599 3.20 2500 100 12:21:01 PM 0:00*28 0.47 214.29 0.068 1.13E-03 97.5 1.599 3.20 2400 100 12:21:29 PM 0:00:28 0.47 214.29 0.068 1.13E-03 97.5 1.599 3.20 2300 100 12:21:57 PM 00028 0.47 214.29 0.068 1.13E-03 97.5 1.599 3.20 2200 100 12:22:25 PM 0:00:28 0.47 214.29 0.068 1.13E-03 97.5 1.599 3.20 2100 100 12:22:52 PM 0:00:27 0.45 222.22 0.070 1.17E-03 101.1 1.659 3.32 2000 100 12:23:19 PM 00027 0.45 222.22 . 0.0701 1.17E-03 101.1 1.659 3.32 I Natural Moisture: 10.4% % Passing #200 : 13.1% ESTIMATED FIELD KSAT:1 0.072 1.19E-03 103.11 1.6911 3.38 Q§CS Class.: SM Consistency: Very loose to loose Depth to an Impermeable Layer: NA Notes: Ksat Class =High Structure/Fabric: NA Slope/Landsc: NA JDepth to Bedrock ...................:. NA I Precision Permeameteiim $OI1 tdtIOM �111G,�ft Cyan .r rmt Virginia Beach Office 204 Grayson Road Virginia (leach, VA 23462 (757)318-1703 Williamsburg Office 1592 Penniman Rd. Suite E Williamsburg, Virginia 23185 (757)564-6452 CLASSIFICATION SYSTEM FOR SOIL EXPLORATION Elizabeth City Office 504 East Elizabeth St. Suite 2 Elizabeth City, NC 27909 (252) 335-9765 Standard Penetration Test (SPT), N-value Standard Penetration Tests (SPT) were performed in the field in general accordance with ASTM D 1586. The soil samples were obtained with a standard 1.4" I.D., 2" O.D., 30" long split -spoon sampler. The sampler was driven with blows of a 140 Ib. hammer falling 30 inches. The number of blows required to drive the sampler each 6-inch increment (4 increments for each soil sample) of penetration was recorded and is shown on the boring logs. The sum of the second and third penetration increments is retorted the SPT N-value. NON COHESIVE SOILS (SILT, SAND, GRAVEL and Combinations) Relative Density Very Loose 4 blows/ft. or less Loose 5 to 10 blows/ft. Medium Dense 1 I to 30 blows/ft. Dense 31 to 50 blows/ft, Very Dense 51 blows/ft. or more Particle Size Identification Boulders 8 inch diameter or more Cobbles 3 to 8 inch diameter Gravel Coarse 1 to 3 inch diameter Medium t/r to 1 inch diameter Fine I/, to I/z inch diameter Sand Coarse 2.00 mm to I/, inch (diameter of pencil lead) Medium 0.42 to 2.00 mm (diameter of broom straw) Fine 0.074 to 0.42 mm (diameter of human hair) Silt 0.002 to 0.074 ram (cannot see particles) CLASSIFICATION SYMBOLS (ASTM D 2487 and D 2488) Coarse Grained Soils Mare than 5Nb retained on No. 200 sieve GW - Well -graded Gravel GP - Poorly graded Gravel GW-GM - Well -graded Gravel w/Silt GW-GC - Well -graded Gravel w/Clay GP -GM - Poorly graded Gravel w/Silt GP -GC - Poorly graded Gravel w/Clay GM - Silty Gravel GC - Clayey Gravel GC -GM - Silty, Clayey Gravel SW - Well -graded Sand SP - Poorly graded Sand SW-SM - Well -graded Sand w/Silt SW -SC - Well -graded Sand w/Clay SP-SM - Poorly graded Sand w/Silt SP-SC - Poorly graded Sand w/Clay SM - Silty Sand SC - Clayey Sand SC-SM - Silty, Clayey Sand Fine -Grained Soils 5M6 or more passes the No. 200 sieve CL - Lean Clay CL-ML - Silty Clay ML - Silt OL - Organic Clay/Silt Liquid Limit 50a. or greater CH - Fat Clay MH - Elastic Silt OH - Organic Clay/Silt Highly OrOrgamc Soils PT - Peat A. JUN 1 3 2011 I Page 1 of GET Revision 12112/07 COHESIVE SOILS (CLAY, SILT and Combinations) Consistency Very Soft 2 blows/ft. or less Soft 3 to 4 blows/ft. Medium Stiff 5 to 8 blows/ft. Stiff 9 to 15 blows/ft. Very Stiff 16 to 30 blows/ft. Hard 31 blows/h. or more Relative Proportions Descriptive Tenn. Perceat Trace 0-5 Few 5-10 Little 15-25 Some 30-45 Mostly 50-100 Strata Changes In the column "Description" on the boring log, the horizontal lines represent approximate strata changes. Groundwater Readings Groundwater conditions will vary with environmental variations and seasonal conditions, such as the frequency and magnitude of rainfall patterns, as well as tidal influences and man-made influences, such as existing swales, drainage ponds, underdrains and areas of covered soil (paved parking lots, side waiks, etc.). Depending on percentage of fines (fraction smaller than No. 200 sieve size), coarse -grained soils are classified as follows: Less than 5 percent GW, GP, SW,SP More than 12 percent GM, GC, SM, SC 5 to 12 percent Borderline cases requiring dual symbols G0 67 a Plasticity Chart MM 111_MEEM■■ 3 t0 2n SJ a:; CJ ti0 7:) F.0 80 fl)9 LIQUID LIMIT (LL) (%v)