Loading...
HomeMy WebLinkAboutSW8060530_HISTORICAL FILE_20180223STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 2.d18 0223 YYYYMMDD ROY COOPER Governor t MICHAEL S. REGAN Secretary Energy, Mineral& WILLIAM E. (TOBY) VINSON, JR. D Land Resources ENVIRONMENTAL OUALITY February 23, 2018 UNC Wilmington Attn: Vice Chancellor for Business Affairs C/o Mark Morgan, Associate Vice Chancellor for Business Affairs -Facilities 601 S. College Rd. Wilmington, NC 28403 Subject: Stale Slormwater Management Permit No. SW8 060530 Hurst Hamilton Parking Lots Project with Areas of both High Density and Low Density New Hanover County Dear Mi. Morgan The Wilmington Regional Office received a complete, modified State Stonnwater Management Permit Application for the subject project on February 22, 2018, Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forl'h in Title 15A NCAC 2H.1000 effective January 1, 2017. We are forwarding modified Permit No. SW8 060530 dated February 23, 2018, for the construction, operation and maintenance of the stormwater control measures (SCMs), built -upon areas, as well as the stormwater collection system and/or vegetated conveyance system associated with the subject project. Please add the atioched plans to the previously approved plan set. Please replace the previous application (SWU-101), supplement, and operation and maintenance agreement with the attached modified versions. On August 5, 2009, the Governor signed Session Law 2009-406. This law impacted any development approval issued by the former Division of Water Quality under Article 21 of Chapter 143 of the General Statutes, which was current and valid at any point between January 1, 2008, and December 31, 2010. The law extended the effective period of any stormwater pennit that was set to expire during this time frame to three (3) years from its current expiration date. On August 2, 2010, the Governor signed Session Law 2010-177, which granted an extra year for a total of four (4) years extension. Accordingly, this permit shall now be effective from the date of issuance until dune 16, 2020, which includes all available extensions. The pernultee andlorproiect remain subject to the conditions and limitations asspecified therein and does not supersede any other agency permit that may be required. Please pay special attention to the permit conditions regarding the operation and maintenance of the SCMs, stormwater collection system, and/or vegetated conveyances; the limitation of built -upon area; modification of the project; the procedures for changing ownership of and/or transferring the permit; and the need to renew the permit. Please also pay attention to the permit conditions that requires the recordation of deed restrictions and protective covenants, casements, and the maintenance agreement, which must all be provided along with certification upon completion of the project. Failure to comply with these requirements will result in future compliance problems. Please refer to Attachment 1 for a detailed description of the current proposed major modification and a list of all the past modifications approved during the effective period of the permit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing by filing a written petition with the Office of Administrative Hearings (OAH). The written petition must conform to Chapter 150B of the North Carolina General Statutes and must be filed with the OAl-1 within thirty (30) days of receipt of this permit. You should contact the OAH with all questions regarding the filing fee (if a filing fee is required) and/or the details of the filing process at 6714 Mail Service Center, Raleigh, NC 27699-6714, or via telephone at 919-431-3000, or visit their website at www.NCOAH.com. Unless such demands are made this permit shall be final and binding. Statc of Nonh Carolina I Cnvironmental Quality I Encrgy. Mineral and Land Resources Wilmington Regional Office 1127 Cardinal Drive Extension I Wilmington. NC 29405 910 796 7215 State Stormwater Permit No. SW8 060530 Page 2 of 9 If you have any questions, or need additional information concerning this matter, please contact Christine Hall in the Wilmington Regional Office, at (910) 796-7215. ` Sincerely, William E. (Toby) Vinson, Jr.. PE. CPESC, CPM, Interim Director Division of Energy, Mineral and Land Resources Enclosures: Attachment A — Certification Forms Attachment I — Permitting History GDS/canh: AV\Stormwater\Permits & 1'rojects\2000V060530 HDA2075 02 permit 060530 cc : Calen Jamison, PE, Project Manager; UNCW Daryl Riggings, PE; McAdams Wilmington Regional Office Stormwater File State of Norl h CaaroGna I Ilmlronnwwa1Quallty I Envrgy.Mlncraland Land Resources Wilmingtun Regional04fice 1127Caidlnal Ddvc Extension I Wilminglun.NC 25405 410 796 7215 State Stormwater Management Permit No. SW8 060530 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY, MINERAL AND LAND RESOURCES STATE STORMWATER MANAGEMENT PERMIT DEVELOPMENT WITH AREAS OF BOTH HIGH DENSITY AND LOW DENSITY In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO UNC Wilmington Hurst Hamilton Parking Lots Hurst Drive and Wagoner Drive, Wilmington, New Hanover County Ko tal construction; operation and maintenance of one (1) wet pond ("stormwater control measures" or "SCMs") as well as one (1) area of 24% low density and one (1) area of redevelopment in compliance with the provisions of Title 15A NCAC 2H .1000 effective January 1, 2017 (the "stormwater rules") and the approved stormwater management plans, application, supplement(s), specifications, and other supporting data (the "approved plans and specifications") as attached and/or on file with and approved by the Division of Energy. Mineral and Land Resources (the "Division" or "DEMLR") and considered an enforceable part of this permit. This permit shall be effective from the date of issuance until June 16, 2020 and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the management and volume of stormwater described in the approved plans and specifications. The maximum amount of built -upon area (BUA) allowed for the entire project is 647,989 square feet. 2. The redevelopment portion of this project is exempt from State Stormwater permitting requirements under the following conditions: 1) The project must be constructed as shown on the plans submitted to this Office; 2) the proposed redeveloped BUA of 14,555 square feet does not exceed the existing BUA of 14,760 square feet, and 3) The proposed stormwater control (vegetated sheet flow and a vegetated channel) provides equal protection of surface waters as the existing stormwater control (vegetated sheet flow and a vegetated channel). 3. The low density area must not exceed 24% per the requirements of the stormwater rules. Within this low density area, this permit covers the construction of a total of 25,145 square feet of BUA; which includes 18,253 square feet of proposed BUA and 6,892 square feet of previously permitted BUA. This low density area excludes 22,215 square feet of existing built -upon area in accordance with 15A NCAC 02H.1003(1)(b). 4. The low density area, Drainage Area 2, has maximized dispersed flow of stormwater runoff through vegetated areas and minimized the channelization of flow. Stormwater runoff that could not be released as dispersed flow may be transported by vegetated conveyances with minimum side slopes of 3:1 (H:V) designed to not erode during the peak flow from the 10-year storm event as defined in the stormwater rules and approved by the Division. Page 1 of 5 State Stormwater Management Permit No. SW8 060530 5. Within the low density area, Drainage Area 2, no piping shall be allowed except those minimum amounts necessary to direct stormwater runoff beneath a BUA such as a road or driveway when it cannot be avoided. 6. The drainage area for the on -site stormwater system will be limited to the amount of built -upon area indicated in this permit and the approved plans and specifications. The runoff from all built - upon area within the permitted drainage area of this project must be directed into the permitted stormwater control measure. The stormwater control measure has been designed using the runoff treatment method to handle the runoff from 608,289 square feet of impervious area. This permit does not provide any allocation of built -upon area for future development. 7. A 50-foot wide vegetative setback must be provided and maintained adjacent to all surface waters, measured horizontally from the normal pool elevation of impounded structures, from the top of bank of each side of streams or rivers; and from the mean high waterline of tidal waters, perpendicular to the shoreline in accordance with the stormwater rules and the approved plans and specifications. Within the low density area all stormwater runoff, including roof drains, shall be released as dispersed flow no closer than at the edge of the vegetated setback and at no time shall stormwater runoff be piped into or through the setback. 8. The stormwater control measure is permitted based on the design criteria presented in the sealed, signed and dated supplement and as shown in the approved plans and specifications. These stormwater control measure must be provided and maintained at the design condition. The approved supplement is incorporated by reference into this permit. 9. The peak flow from the 10-year storm event shall not cause erosion downslope of the stormwater outlet discharge point. 10. Decorative spray fountains will be allowed in the stormwater treatment system if documentation is provided demonstrating that the proposed fountain will not cause resuspension of sediment within the pond or cause erosion of the pond side slopes. 11. When using a wet pond for irrigation, it is recommended that some water be maintained in the permanent pool, the vegetated shelf is planted with appropriate species that can handle fluctuating conditions, and human health issues are addressed. 12. The SCM landscape planting plan shown in the approved plans shall be followed in its entirety during construction. After the plants are established, the operation and maintenance agreement must be followed. 13. The stormwater system is permitted as a variation to the requirements under Title 15A NCAC 20H.1003(6) as the forebays (existing and proposed) exceed the 15-20% minimum design criteria. The proposed system provides equal or better stormwater control and equal or better protection of surface waters. If the proposed system is found to not meet the intent of the stormwater rules, the stormwater control measure will have to meet the requirements of the stormwater rule or another alternative must be proposed and a permit modification will be required. II. SCHEDULE OF COMPLIANCE 1. The project and SCM shall be constructed, operated and maintained in accordance with the conditions of this permit and the approved plans and specifications. 2. The on -site stormwater system shall be entirely constructed, vegetated, and operational prior to the construction of any development within the drainage area, per the approved plans and specifications. 3. During construction, erosion shall be kept to a minimum and any eroded areas of the on -site stormwater system will be repaired immediately. If the stormwater system is used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. Page 2 of 5 I State Stormwater Management Permit No. SW8 060530 4. All stormwater control measures, stormwater collection systems vegetated conveyance systems, and/or maintenance accesses must be located in public rights -of -way, dedicated common areas that extend to the nearest public right-of-way, and/or permanent recorded easements that extend to the nearest public right-of-way for the purpose of inspection, operation, maintenance; and repair. 5. The permittee shall provide and perform the operation and maintenance necessary, as listed in the signed Operation and Maintenance Agreement, to assure that all components of the permitted on -site stormwater system functions at the approved design condition. The approved Operation and Maintenance Agreement is incorporated by reference into this permit and must be followed in its entirety and maintenance must occur at the scheduled intervals. 6. The operation and maintenance agreement must be recorded with the Office of the Register of Deeds. 7. Records of maintenance activities must be kept and made available upon request to authorized personnel of the Division. The records will indicate the date, activity; name of person performing the work and what actions were taken. 8. The final plats for the project must be recorded with the Office of the Register of Deeds. The recorded plat must reference the Operation and Maintenance Agreement and must also show all public rights -of -way, dedicated common areas, and/or permanent drainage easements, in accordance with the approved plans. 9. The permittee is responsible for verifying that the proposed built -upon area for the entire project does not exceed the maximum allowed by this permit. 10. Upon completion of the project, the permittee shall determine whether or not the project is in compliance with the permitted plans and take the necessary following actions: a. If the permittee determines that the project is in compliance with the permitted plans, then within 45 days of completion, the permittee shall submit to the Division one hard copy and one electronic copy of the following: i. The completed and signed Designer's Certification provided in Attachment A noting any deviations from the approved plans and specifications. Deviations may require approval from the Division; ii. A copy of the recorded maintenance agreement; iii. Unless already provided, a copy of the recorded deed restrictions and protective covenants, and iv. A copy of the recorded plat delineating the public rights -of -way: dedicated common areas and/or permanent recorded easements, when applicable. b. If the permittee determines that the project is not in compliance with the permitted plans, the permittee shall submit an application to modify the permit within 30 days of completion of the project or provide a plan of action, with a timeline, to bring the site into compliance. 11. No person or entity, including the permittee, shall alter any component shown in the approved plans and specifications. Prior to the construction of any modification to the approved plans, the permittee shall submit to the Director, and shall have received approval for modified plans, specifications, and calculations including, but not limited to, those listed below: a. Any modification to the approved plans and specifications, regardless of size including the stormwater control measures, built -upon area: details, etc. b. Redesign or addition to the approved amount of built -upon area or to the drainage area. c. Further development, subdivision, acquisition, lease or sale of any, all or part of the project area as reported in the approved plans and specifications. d. Altering, modifying, removing, relocating, redirecting, regrading or resizing of any component of the approved stormwater control measure, stormwater collection system and/or vegetative conveyance system shown on the approved plan. e. The construction of any allocated future BUA. f. The construction of any permeable pavement for BUA credit that was not included in the approved plans and specifications. g. The construction of any #57 stone area, public trails, or landscaping material to be considered a permeable surface that were not included in the approved plans and specifications. In. Other modifications as determined by the Director. Page 3 of 5 State Stormwater Management Permit No. SW8 060530 12. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of modified plans and certification in writing to the Director that the changes have been made. 13. Prior to transfer of the permit, a file review and site inspection will be conducted by Division personnel to ensure the permit conditions have been met and that the project and the on -site stormwater system complies with the permit conditions. Any items not in compliance must be repaired, replaced restored, or resolved prior to the transfer. Records of maintenance activities performed to date may be requested. III. GENERAL CONDITIONS 1. Any individual or entity found to be in noncompliance with the provisions of a stormwater management permit or the requirements of the stormwater rules is subject to enforcement procedures as set forth in NCGS 143 Article 21. 2. The issuance of this permit does not preclude the permittee from complying with and obtaining any other permits or approvals that are required for this development to take place, as required by any statutes; rules, regulations, or ordinances, which may be imposed by any other Local, State or Federal government agency having jurisdiction. Any activities undertaken at this site that cause a water quality violation or undertaken prior to receipt of the necessary permits or approvals to do so are considered violations of NCGS 143-215.1, and subject to enforcement procedures pursuant to NCGS 143-215.6. 3. If the facilities fail to perform satisfactorily or fail to meet the requirements of a low density area, the permittee shall take immediate corrective actions. This includes actions required by this Division and the stormwater rules such as the construction of additional or replacement on -site stormwater systems. These additional or replacement measures shall receive a permit from the Division prior to construction. This permit is not transferable to any person or entity except after notice to and approval by the Director. The permittee shall submit a completed and signed State Stormwater Request Form for Permit Transfer or Permit Information Update; accompanied by the supporting documentation as listed on the form, to the Division at least 60 days prior to any one or more of the following events: a. Any ownership change including: i. The sale or conveyance of the project area in whole or in part, except in the case of an individual lot sale that is made subject to the recorded deed restrictions and protective covenants; ii. Dissolution of the partnership or corporate entity, subject to NCGS 57D-2-01(e) and NCGS 57D-6-07; b. Bankruptcy; c. Foreclosure, subject to the requirements of Session Law 2013-121; d. A name change of the current permittee; e. A name change of the project; f. A mailing address change of the permittee; 5. The permittee is responsible for compliance with all terms and conditions of this permit until the Division approves the transfer request. Neither the sale of the project, in whole or in part, nor the conveyance of common area to a third'party constitutes an approved transfer of the permit. 6. The permittee grants Division Staff permission to enter the property during normal business hours to inspect all components of the permitted project. 7. The permit issued shall continue in force and effect until the permittee files a request with the Division for a permit modification, transfer, renewal, or rescission; however, these actions do not stay any permit conditions. 8. Approved plans, application documents, supplements, calculations, operation and maintenance agreement, and specifications for this project are incorporated by reference and are enforceable parts of the permit. A copy of this permit, application, supplements, operation and maintenance agreement, and approved plans and specifications shall be maintained on file by the permittee. Page 4 of 5 State Stormwater Management Permit No. SW8 060530 9. Unless specified elsewhere; permanent seeding requirements for the on -site stormwater system must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 10. The issuance of this permit does not prohibit the Director from reopening and modifying the permit, revoking and reissuing the permit, or terminating the permit for cause as allowed by the laws, rules, and regulations contained in Title 15A NCAC 2H.1000 and NCGS 143-215.1 et.al. 11. A permit renewal request must be submitted at least 180 days prior to the expiration date of this permit. The renewal request must include the appropriate application, documentation and the processing fee as outlined in Title 15A NCAC 02H. 1 045(3). Permit modified and reissued this the 2311 day of February 2018. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION j7;,William Ed(Toby) Vinson, Jr., PE. CPESC, CPM, Interim Director Division of Energy; Mineral and Land Resources By Authority of the Environmental Management Commission Permit Number SW8 060530 Page 5 of 5 State Stormwater Management Permit No. SW8 060530 Attachment A Certification Forms The following blank Designer Certification forms are included and specific for this project: • As -Built Permittee Certification • As -Built Designer's Certification General MDC • As -Built Designer's Certification for Wet Detention Pond Project • As -Built Designer's Certification for Low Density Projects A separate certification is required for each SCM. These blank certification forms may be copied and used, as needed, for each SCM and/or as a partial certification to address a section or phase of the project. Page 1 of 1 State Stormwater Management Permit No. SW8 060530 AS-13UI1,1' I'I:RNII7"I'I;I: CERTIFICATION I hereby state that I am the current permittee for the project named above, and I certify by my signature below, that the project meets the below listed Final Submittal Requirements found in NCAC 021-1.1042(4) and the terns, conditions and provisions listed in the permit documents, plans and specifications on file with or provided to the Division. Check here ifthis is a partial certification. Sect ion/phase/SCN9 V Check here ifthis is par ofa Fast Track As -built Package Submittal. Printed County of a Notary Public in the State of do hereby certify that personally appeared before me this day of 120 and acknowledge the due execution of this as -built certification. (S1,A1.,) Witness my hand and official seal My commission expires Permittee's Certification NCAC .1042(4) Completed i Provided N/A A. DEED RESTRICTIONS / BUA RECORDS 1. The deed restrictions and protective covenants have been recorded and Y or N contain the necessary language to ensure that the project is maintained consistent with the stormwatcr regulations and with the permit conditions. 2. A copy of the recorded deed restrictions and protective covenants has been Y or N provided to the Division. 3. Records which track the 13UA on each lot are being kept. (SceNotc 1) Y or N 13. MAINTENANCE, ACCESS 1. The SCMs are accessible for inspection, maintenance and repair. Y or N 2. The access is a minimum of 10 feet wide. Y or N 3. The access extends to the nearest public right-of-way. Y or N C. EASEMENTS 1. The SCN9s and the components of the runoff collection / conveyance system Y or N are located in recorded drainage casements. 2. A copy of the recorded plat(s) is provided. Y or N D. SINGLE FAMILY RESIDENTIAL LOTS - Plats for residential lots that Y or N have an SCM include the following: I. The specific location of the SCM on the lot. Y or N 2. A typical detail for the SCM. Y or N 3. A note that the SCN9 is required to meet stormwatcr regulations and that the lot owner is subject to enforcement action as set forth in NCGS 143 Article Y or N 21 if the SCM is removed. relocated or altered without prior approval. E. OPERATION AND MAINTENANCE AGREEMENT Y or N 1. The O&M Agreement is referenced on the final recorded plat. Y or N 2. The O&M Agreement is recorded with the Register of Dceds and appears in Y or N the chain oftitle. F. OPERATION AND MAINTENANCE PLAN — maintenance records are y N beingkept in a known set location for each SCM and are available for review. or G. DESIGNER'S CERTIFICATION FORM — has been provided to the Y or N Division. Notel- Acceptable records include ARC approvals, as -built surveys, and county tax records. Page 1 of 8 State Stormwater Management Permit No. SW8 060530 Provide an explanation for every requirement that was not met, and for every ''N/A" below. Attach additional sheets as needed. Page 2 of 8 State Stormwater Management Permit No. SW8 060530 AS-IIIiILT llI;SIGNI?R'S CEIYI'IPICA'1'1(lN GI?NERAL MDC 1 hereby state that I am a licensed professional and I certify by my signature and seal below, that I have observed the construction of the project named above to the best of my abilities with all due care and diligence, and that the project meets the below listed General NIDC found in NCAC 021-1.1050 in accordance with the permit documents, plans and specifications on file with or provided to the Division, except as noted on the "AS - BUILT" drawings, such that the intent of the stormwater rules and statutes has been preserved. Check here if this is a partial certification. Sect ion/phase/SCNf ii? Check here if this is a part of a Fast -Track As -Built Package Submittal per .1044(3). Check here if the designer did not observe the construction, but is cenifying the project. Check here if pictures of the SCM are provided. Printed NC Registration Number Date SPAL: Consultant's Mailing Address: City/State/ZIP Phone Number Consultant's Email address: 1) Circle N if the as -built value differs from the flan. If N is circled, provide an explanation on Page 2. ON/B = not evaluated (provide explanation on page 2) 3N/A = not applicable to this SCNI or project. Consultant's Certification NCAC .1003((3) & General MDC .1050 OAs-built ON/E OO N/A A. TREATMENT REQUIREMENTS 1. The SCM achieves runoff treatment. Y or N 2. The SCN-I achieves runoff volume match. Y or N 3. Runoff from offsite areas and/or existing 13UA is bypassed. Y or N 4. Runoff from offsite areas and/or existing BUA is directed into Y or N the permitted SCM and is accounted for at the full build -out potential. 5. The project controls runoff through an offsitc permitted SCNf Y or N that meets the requirements of the MDC. 6. The net area of new BUA increase for an existing project has Y or N been accounted for at the appropriate design storm level. 7. The SCM(s) meets all the specific minimum design criteria. Y or N B. VEGETATED SETBACKS / BUA I . The width of the vegetated setback has been measured from Y or N the normal pool of impounded waters, the N-lI IW line of tidal waters or the top of bank of each side of rivers or strunns. 2. The vegetated setback is maintained in grass or other Y or N vegetation. 3. 131JA that meets the requirements ofNCGS 143-214.7 (b2)(2) Y or N is located in the setback. 4. 13UA that does not meet the requirements of NCGS 143-214.7 Y or N (b2)(2) is located within the setback and is limited to: a. publicly funded linear prgjects (road, greenway sidewalk) b. Water -dependent structures c. Minimal footprint uses (utility poles, signs, security lighting and appurtenances 5. Stormwater that is not treated in an SCM is released at the Y or N edge of the setback and allowed to flow through the setback as dispersed flow. Page 3 of 8 State Stormwater Management Permit No. SW8 060530 OAs-built ON/E OO N/A C. STORM WATER OUTLETS — the outlet handles the peak flow y N from the 10 ear storm with no downslope erosion. or D. VARIATIONS 1. eA variation (alternative) from the stormwater rule provisions has been implemented. or 2. "I'hc variation provides equal or better stonnwatcr control and Y N cc ual or better protection of surface waters. or E. COMPLIANCE WITH OTHER REGULATORY Y N PROGRAMS has been met. or F. SIZING -the volume of the SCM takes the runoff from all surfaces into account and is sufficient to handle the required storm Y or N depth. G. CONTAMINATED SOILS — infiltrating SCM's are not located Y or N in or on areas with contaminated soils. H. SIDE SLOPES 1. Vegetated side slopes are no steeper than 311:1 V. Y or N 2. Side slopes include retaining walls; gabion walls; or other y or N surfaces that are steeper than 3H:1 V. 3. Vegetated side slopes are steeper than 311:1 V (provide Y or N Supporting documents for soils and vegetation). 1. -EROSION PROTECTION 1. The inlets do not cause erosion in the SCM. Y or N 2. The outlet does not cause erosion downslope of the discharge Y or N point during the peak flow from the 10 year storm. J. EXCESS FLOWS — An overflow / bypass has been provided. Y or N K. DEWATERING —A method to drawdown standing water has Y or N been provided to facilitate maintenance and inspection. L. CLEAN OUT AFTER CONSTRUCTION —the SCM has been Y or N cleaned out and converted to its approved design state. M. MAINTENANCE ACCESS 1. The SCM is accessible for maintenance and repair. Y or N 2. The access does not include lateral or incline slopes >3:1. Y or N N. DFSIGNF,R QUALIFICATIONS (FAST -TRACK PERMIT) — The designer is licensed under Chapters 89A, 89C, 89E, or 89F of Y or N the General Statutes. Provide an explanation for every MDC that was not met, and for every item marked "N/A" or "N/E", below. Attach additional pages as needed: Page 4 of 8 State Stormwater Management Permit No. SW8 060530 AS-BGII� 1' DESIGNEWS CERTIFICATION FOR WET DF; fE HON POND PROJ1CT 1 hereby state that I am a licensed professional and I certify by my signature and seal below, that I have observed the construction of the project named above to the best of my abilities with all due care and diligence, and that the project meets all of the NIDC found in NCAC 0211.1053, in accordance with the permit documents, plans and specifications on file with or provided to the Division_ except as noted on the "AS -BUILT' drawings, such that the intent of the stormwater rules and the general statutes has been preserved. Check here if this is a partial certification. Sect ion/phase/SCNI .'.'? Check here if this is part of a Fast -Track As -Built Package Submittal per. 1044(3). Check here if the Designer did not observe the construction, but is certifying the project. Check here if pictures ofthe SCAM are provided. Printed Name NC Registration Number SEAL: Signature_ Date Consultant's Mailing Address: City/State/%IP Phone Number Consultant's Email address: T Circle N if the as -built value differs from the Plan/permit. If N is circled, provide an explanation on page 2 OO N/E = not evaluated (provide explanation on page 2) ON/A = not applicable to this project or SCAM. This Certification must be completed in conjunction with the General NIDC certification underNCAC 021-1.1050 Consultant's Certification (.VIDC .1053) Or As -built OO N/E OO N/A A. Foreba / Depths / Fountain 1. The available Sediment storage is consistent with the approved Y N plan and is a minimum of 6 in. or 2. Water [low over the forebay bean into the main pond occurs at a Y N non -erosive velocity. or 3. The provided Eorebay Volume is 15%-20% of the main pool Y N volume. or 4. The Forebav entrance elevation is deeper than the exit elevation Y N into the pond. or 5. The Average Design Depth of the main pond below the y N permanent pool elevation is consistent with the permitted value? or 6. Fountain documentation is provided. Y or N B. Side slopes / Banks / Ve 'etated Shelf I. The width of the Vegetated Shelf is consistent with the approved Y N plans and is a minimum of 6 feet. or 2. The slope of the Vegetated Shelf is consistent with the approved Y N Mans and is no steeper than 6:1. or C. As -built Main Pool / Areas / Volumes / Elevations I . ']'he permanent pool surface area provided is consistent with the I Y N permitted value. or 2. "The Temporary Pool Volume provided is consistent with the Y N permitted value. or 3. The permanent pool elevation is consistent with the permitted Y N value. or 4. The temporary pool elevation is consistent with the permitted Y N value. or Page 5 of 8 State Stormwater Management Permit No. SW8 060530 tOAs-built ON/E OO N/A D. Inlets / Outlet / Drawdown l . The design volume draws down in 2-5 days. Y or N 2. The sire of the Orifice is consistent with the permitted value. Y or N 3. A trash rack is provided on the outlet structure. Y or N 4. Hydrologic impacts to the receiving channel are minimized from Y N the I yr 24 hr stortn discharge? or 5. The inlets and the outlet location are situated per the approved Y N' Ian and avoid short-circuiting. or F. Ve etation I. The vegetated shelf has been planted with a minimum of') Y N diverse species. or 2. The vegetated shelf plant density is consistent with the approved plans and is no Tess than 50 plants per 200 sf or no Iess than 24 Y or N inches on center. Provide an explanation for every MDC that was not met; and for every item marked 'N/A" or "N/F below. Attach additional pages as needed: Page 6 of 8 State Stormwater Management Permit No. SW8 060530 AS -BUILT DESIGNER'S CERTIFICATION FOR LO)V D1:NSITY PROJECTS I hereby state that I am a licensed professional and I certify by my signature and seal below that I have observed the construction of the low density project named above to the best of my abilities with all due care and diligence, and that the project meets all of the MDC found in NCAC 021-1.1003 and is consistent with the permit documents; plans and specifications on file with or provided to the Division, except as noted on the "AS - BUILT" drawings, such that the intent of the stormwater rules and the general statutes has been preserved. Check here if this is a partial certification. Section or phase? Check here ifthis.is part of a Past -Track As -Built Package Submittal per .1044(3). Check here if the Designer did not observe the construction but is certifying the project. Check here if pictures of the project are provided. Printed Name NC Registration Number SEAL: Signature Consultant's Mailing Address: City/State/ZIP Phone Number Consultant's Email Address: OO Circle N if the as -built value differs from the Plan/Permit. If N is circled, provide an explanation on page 2. OO N/E = not evaluated (provide explanation on page 2) OO N/A = not annlicable to this protect / plan. Consultant's Certification (MDC .1003) tOAs-built Oz N/E Oa N/A A. Project Density and Built -Upon Area 1. The project has areas of high density based on natural drainage Y N --r- area boundaries, variations in land use or construction phasin . or 2. The project's built -upon area does not exceed the maximum limit Y N specified in the permit. or B. Dispersed Flow —the project maximizes dispersed flow through Y N vegetated areas and minimizes channelized flow. or C. Vegetated Conveyances 1. Stormwater that is not released as dispersed flow is transported Y N by vegetated conveyances. or l 2. The project has a minimal amount of non -vegetated conveyances y N to reduce erosion. or 3. Other than minimal piping under driveways and roads, no piping Y N has been added beyond what is shown on the approved plans. or 4. Side slopes are no steeper than 3H:1 V. Y or N 5. The conveyance does not erode in response to the peak flow from Y N the 10 year storm. or D. Curb outlet systems - the project uses curb & gutter with outlets to Y N grassed swales or vegetated areas that meet the following criteria: or 1. The swalc or vegetated area can carry the peak flow from the 10 Y N storm at a non -erosive velocity. or 2. The longitudinal slope of the Swale or vegetated areas does not Y N exceed 5%. or 3. The swale has a trapezoidal cross-section and a minimum bottom Y N width of two feet. or 4. The minimum length of the swale or vegetated area is 100 feet. Y or N 5. Side slopes are no steeper than 31-I:1 V. Y or N 6. The project utilizes treatment swales designed per Section .1061 Y N in lieu of the curb outlet system requirements. or Page 7 of 8 State Stormwater Management Permit No. SW8 060530 CAs-built ©N/E OO N/A E. Vegetated Setbacks I . The width of the vegetated setback is 1' or N 2. The width of the vegetated setback hass be been measured from the normal pool of impounded waters, the NIHW line of tidal waters, Y or N or the top of bank of each side of rivers or streams. 3. The vegetated setback is maintained in grass or other vegetation. Y or N 4. BUA that meets the requirements of NCGS 143-214.7(b2)(2) is N located in the setback. or 5. 131JA that does NOT meet the requirements of NCGS 143- 214.7(b2)(2) is located within the setback and is limited to: a. Publicly funded linear projects (road, greemvay, or sidewalk) Y N b. Water dependent structures or c. Minimal footprint uses such as poles, signs, utility appurtenances, and security lights. 6. The amount of 13liA within the setback is minimized and channeling of the runoff from the 13UA has been avoided. Y or N 7. Stonnwatcr is not discharged (via swalc or pipe) through a vegetated setback. Stonnwater is released at the edge of the y N setback and allowed to flow through the setback as dispersed {]OW. or F. Outlets — stormwater outlets do not cause erosion downslope of the y N dischar e oint duringthe peak flow from the 10 year storm. or G. Variations — the project has variations from the MDC that were not N I y previously approved. Modification may be required) or H. Deed restrictions (if required) — are recorded and ensure that the project and the 13UA will be maintained in perpetuity consistent with Y or N the permit, approved plans andspecifications. I. For Subdivisions Only (Residential or Commercial) 1. The number of platted lots is consistent with the approved plans. Y or N 2. The project area is consistent with the approved plans. Y or N 3. The layout of the lots and streets is consistent with the approved N'or plan. 4. The width / radius of streets, paved accesses, cul-de-sacs and Y N sidewalks is consistent with the approved plan. or 5. No piping, other than those minimum amounts needed under a Y N drivewav or under a road has been added. or 6. The lot grading, road grading, vegetated conveyances, piping NII inverts, and elevations are consistent with the approved plans. or Provide an explanation for every MDC that was not met, or for every deviation from the permitted condition below: Page 8 of 8 Attachment 1 - Permitting History Hurst Hamilton Parking Lots Permit No. SW8 060530 Approval Permit Action RIMS Description of the Changes Date Version 6/1612006 Original Approval 1.0 * Adding 13UA for the Cross-City"Dail and 80,400 sf of future 1311A allocation 5/14/2010 Modification 1.1 * Revised drainage area boundary * The construction of two additional parking lots subject to the 2017 Rules. 2/23/2018 Major Modification 1.2 * Expanding the wet pond to Handle the increased runoff, which has been designed per the 2017 MDC. Page 1 of 1 0 DEMLR USE ONLY • Date Received Fee Paid Permit Number I loa r4 154 o Applicable Rules: ❑ Coastal SW -1995 ❑ Coastal SW - 2008 ❑ Ph II - Post Construction (select all that apply) ❑ Non -Coastal SW- HQW/ORW Waters ❑ Universal Stormwater Management Plan ❑ Other WQ M mt Plan: State of North Carolina Department of Environment and Natural Resources Division of Energy, Mineral and Land Resources STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original I. GENERAL INFORMATION 1. Project Name (subdivision, facility, or establishment name -should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): UNC Wilmington - Hurst Hamilton Parking Lots 2. Location of Project (street address): Hurst Drive and Wagoner Drive City: Wilmington County: New Hanover Zip: 28403 3. Directions to project (from nearest major intersection): Project is located at the NW corner of the intersection of Hurst Drive and Hamilton Drive and NE of Hamilton Drive and MacMillan Avenue 4. Latitude: 34' 13' 16" N Longitude: 77' 52' 47" W of the main entrance to the project. 11. PERMIT INFORMATION: 1. a. Specify whether project is (check one): ❑New ®Modification ❑ Renewal w/ Modificationt tRenewals mith modifications also requires SWU-102 - Reneuial Application Form b.If this application is being submitted as the result of a modification to an existing permit, list the existing permit numberSW8 060530 , its issue date (if known)May 14, 2010 , and the status of construction: ®Not Started ❑Partially Completed* ❑ Completed* *provide a designer's certification 2. Specify the type of project (check one): ,®Low Density ®High Density ❑Drains to an Offsite Stormwater System ❑Other 3. If this application is being submitted as the result of a previously returned application or a letter from DEMLR requesting a state stormwater management permit application, list the stormwater project number, if assigned, and the previous name of the project, if different than currently proposed, CC ^` r 4. a. Additional Pioject Requirements (check applicable blanks; information on required sta dab ILK En obtained by contacting the Customer Service Center at 1-877-623-6748): ❑LAMA Major ®Sedimentation/Erosion Control: 9.75 ac of Dist ed 9 B c018 ❑NPDES Industrial Stormwater ❑404/401 Permit: Proposed Impacts b.If any of these permits have already been acquired please provide the Project Name, Project/Permit Number, issue date and the type of each permit:UNC Wilmington - Hurst Parking Lots - Modification/NEWHA-2018- 5. Is the project located within 5 miles of a public airport? []No ®Yes If yes, see S.L. 2012-200, Part VI: http://portal.ncdenr.org/web/Ir/rules-and-regulations Form SWU-101 Version Oct. 31, 2013 Page I of f�,r; :: � �,a,. III10Mi1tlSr IJIto]L41 1: a. Print Applicant / Signing Official's name and title (specifically the developer, property owner, lessee, designated government official, individual, etc. who owns the project): Applicant/Organization: UNC Wilmington Signing Official & Title: Mark Morgan / Associate Vice Chancellor for Business Affairs -Facilities b.Contact information for person listed in item la above: Street Address:601 S. College Road City:Wilmington State:NC Zip:29403 Mailing Address (if applicable): City: Phone: ( 910 1 962-3761 Email: morganm@uncw.edu State: Zip: Fax: (910 ) 962-7140 c. Please check the appropriate box. The applicant listed above is: ® The property owner (Skip to Contact Information, item 3a) ❑ Lessee* (Attach a copy of the lease agreement and complete Contact Information, item 2a and 2b below) ❑ Purchaser* (Attach a copy of the pending sales agreement and complete Contact Information, item 2a and 2b below) ❑ Developer* (Complete Contact Information, item 2a and 2b below.) 2. a. Print Property Owner's name and title below, if you are the lessee, purchaser or developer. (This is the person who owns the property that the project is located on): Property Owner/Organization: Signing Official & b.Contact information for person listed in item 2a above: Street Address: Mailing Address (if applicable): Phone: ( 1 Fax: Email: 3. a. (Optional) Print the name and title of another contact such as the project's construction supervisor or other person who can answer questions about the project: Other Contact Person/Organization:UNC Wilmington Signing Official & Title:Galen Jamison, PE / Project Manager b.Contact information for person listed in item 3a above: Mailing Address:601 South College Road City: W ilmington Phone: (910 ) 962-2677 Email: isongflunc w. ed u 4. Local jurisdiction for building permits: Point of Contact: Form SWU-101 Version Oct. 31, 2013 Page 2 of 6 r WZ%zzY.- IV. , PROJECT INFORMATION 1. In the space provided below, briefly summarize how the stormwater runoff will be treated. Development onsite consists of the construction of two new parking lots Impervious created from the construction of the lots will be directed into the existing regional stormwater Rood, which is to be modified from the construction of this project. 2. a. If claiming vested rights, identify the supporting documents provided and the date they were approved: ❑ Approval of a Site Specific Development Plan or PUD Approval Date: ❑ Valid Building Permit Issued Date: ❑ Other: natp. b.If claiming vested rights, identify the regulation(s) the project has been designed in accordance with: ❑ Coastal SW -1995 ❑ Ph II - Post Construction 3. Stormwater runoff from this project drains to the Cape Fear River basin. 4. Total Property Area: 26.81 acres 5. Total Coastal Wetlands Area: 0 acres 6. Total Surface Water Area: 0 acres 7. Total Property Area (4) - Total Coastal Wetlands Area (5) - Total Surface Water Area (6) = Total Project Area':26.81 acres Total project area shall be calculated to exclude the following the normal pool of im ounded structures, the area between the banks of streams and rivers, the area below the Normal High Water (NSW) line or Mean High Water (MHW) line, and coastal wetlands landward from the NHW (or MHW) line. The resultant project area is used to calculate overall percent built upon area (BLIA). Non -coastal wetlands landward of the NHW (or MHW) line may be included in the total project area. 8. Project percent of impervious area: (Total Impervious Area / Total Project Area) X 100 = 49.75 9. How many drainage areas does the project have?7 (For high density, count 1 for each proposed engineered stormwater BMP. For low density and other projects, use 1 for the whole property area) 10. Complete the following information for each drainage area identified in Project Information item 9. If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. Basin Information Stream Name Draina e Area DrainageReceiving Stream ClassStream Index Number 4Drainae Total Drainage Area (so On -site Drainage Area (so Off -site Drainage Area (sf) Proposed Impervious Area** s Impervious Area** total Im ervious** Surface Area Draina e Area _ Draina e Area _ Draina e Area Draina a Area On -site Buildings/Lots (so _ On -site Streets (so On -site Parking (so 1 On -site Sidewalks (so Other on -site (so Future (so Off -site (so N � Existing BUA*** (so Total (sf): -- Wuu ,nucA Number can ve determined at: nttp://Portal nedenr org/weL&wq s/esu/classifications Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. * Report only that amount of existing BUA that will remain after development. Do not report any existing BUA that is to be removed and which will be replaced by new BUA. Form SWU-101 Version Oct.31, 2013 Page 3 of Permit: SW8OW530 Protect Number: UN W-1T060 ATTACHMENT A Drainage Area/Impervious Breakdown Basin Information Drainage Area to SCM REDEVELOPMENT EXEMPTION Drainage Area LOW DENSITY Drainage Area TOTAL Recewing Stream Name Burnt Mill Creek Burnt Mill Creek Burnt Mill Creek Stream Uass q5w GSw C;5w Stream Index Number 18-74-63-2 18d4-63-2 18-94.63-2 Total Drainage Area lrp 1,218,903 14,555 139,687 1,373,145 On-SWS OW530 &On-UNCW Property Drainage Area (sfl 1,030,146 14,555 121,413 1,1W,114 On-SW8060530&Off-UNCW PropertyD=inage Area lsQ 6,029 3,566 9,fi45 Off-SW8 OW530 &On-UNCW Property Drainage Area (sf) 144,959 0 14g959 Off-SW8=530&Off-VNCW Property Drainage Area isQ 32,219 0 32,719 ROW Drainage Area (sff 0 1B708 14,708 Total Proposed Impervious Area (sf) 608,289 14,555 25,145 64T,989 On-SW8060530 Proposed Impervious Area 525,153 14,555 19,746 08,520 ROW Proposed Impervious Area 0 5,399 5,399 Total% Impervious Area 49.90% iW.0094; 18.009E 47.19% On-SW8060530%Impervious Area SSSM 1W.00% 35.801" 52.1814 ROW %Impervious Area 3673% 36]3% Im"Mous Surface Area Drainage Area to SCM REDEVELOPMENT EXEMPTION Drainage Area LOW DENS" Drainage Area TOTAL On-siteSW8060530 Buildings/Lots(s_f) 0 0 0 on -site IWO 00530 sm,eu(so 0 - 0 0 On -site SW800530 Parking(sfl 186,959 11,600 3,228 201,787 On -site SW8060530 Sidewalks lafl IAB85 2,955 8,692 26,532 1988-2W8 Iq`5 IJ e�S 352,597 - 6,892 359.499 2008-2017 (J� ,�' -a�� 5,952 - 0 5,952 SW8031039 13,154 0 13,154 SW81W405 10,428 0 10,428 Off-UNCW Procerty&Off-SWB 0W530(If) 19M.2008 (Sea6owk Syuort & rmallpation a/Collepe flGJ 9,554 - 0 9,554 Off-UNCW PmceM& On SW8 060530 (If) 1988-2008 (-- AtuaA+inon A-) 0 - 383 383 Off-UNCW Property&On-SW8060530 III Past 2017 (--Pbac illon Aye) 0 - 551 551 ROW (sff 29M 2W8 0 1,989 1,989 ROW Is_tl Post 2017 0 3,410 ROW Existing Pre 19W BUA 1.0 0 _ 20,409 'X' 0 On-SIMS W530 Existing Pre-198B BUA (If) 14,260 1,806 'IE 14,260 Total (In W0,289 14,555 647,989 •This permit unhoes reaeuelopment ereii by treating l/)W If of eaktiry P-19811 BUA, allaxiry 14,5S5 If of propauG impentausto be bypased• * p 1) YC Total Drainage Arta to SCM= 1,218,903 12.98 'Drainage Area Total -Drainage Area LOW DENSITY' = LOW DEN51"Y = iTolal Drainage 161,902 Areal lE,ating Pre-1988 BUAl O, Q' Total 'Inralin9 PrN9888VA'= 2221 If sf Q y 'Drainage Area LOW DENSITY'= 139,07 1 1 4 u �I Total Permit BounearY Area 1.231,6e: 27,84 If ,bb �U O p[ a a,a to •Y • T FEB 14 2018 BY: 2/13/2018' 11. How was the off -site impervious area listed above determined? Provide documentation. } Projects in Union County: Contact DEMLR Central QJJice staff to check if the project is located within a Threatened & Endangered Species watershed that maybe subject to more stringent stormwater requirements as per 15A NCAC 02B .0600. [��Y�l Y rJ IF�t1►i! 17.�►i�Z�I.'±�t�il��]l�u (,7 The applicable state stormwater management permit supplement and operation and maintenance (O&M) forms must be submitted for each BMP specified for this project. The latest versions of the forms can be downloaded from http://portal.ncdenr.org/web/wq/ws/su/bmp-manual. VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Energy, Mineral and Land Resources (DEMLR). A complete package includes all of the items listed below. A detailed application instruction sheet and BMP checklists are available from http://portal.ncdenr.org/web/wq/ws/su/statesw/forms does. The complete application package should be submitted to the appropriate DEMLR Office. (The appropriate office may be found by locating project on the interactive online map at http://12ortal.ncdenr.org/web/wq/ws/so/maps.) Please indicate that the following required information have been provided by initialing in the space provided for each item. All original documents MUST be signed and initialed in blue ink. Download the latest versions for each submitted application package from http://portal.ncdenr.ory/web/wq/ws/so/statesw/forms does. Initia 1. Original and one copy of the Stormwater Management Permit Application Form. 2. Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants A114- Form. (if required as per Part V11 below) 3. Original of the applicable Supplement Form(s) (sealed, signed and dated) and O&M agreement(s) for each BMP. 4. Permit application processing fee of $505 payable to NCDENR. (For an Express review, refer to http://www.envhelp.org/pages/onestopexpress.html for information on the Express program and the associated fees. Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required application meeting.) 5. A detailed narrative (one to two pages) describing the stormwater treatment/managementfor the project. This is required in addition to the brief summary provided in the Project Information, item 1. 6. A USGS map identifying the site location. If the receiving stream is reported as class SA or the receiving stream drains to class SA waters within 1/2 mile of the site boundary, include the '/z mile radius the map. 7. Sealed, signed and dated calculations (one copy). 8. Two sets of plans folded to 8.5" x 14" (sealed, signed, & dated), including: a. Development/Project name. b. Engineer and firm. c. Location map with named streets and NCSR numbers. d. Legend. e. North arrow. f. Scale. g. Revision number and dates. h. Identify all surface waters on the plans by delineating the normal pool elevation of impounded structures, the banks of streams and rivers, the MHW or NHW line of tidal waters, and any coastal wetlands landward of the MHW or NHW lines. • Delineate the vegetated buffer landward from the normal pool elevation of impounded structures, the banks of streams or rivers, and the MHW (or NHW) of tidal waters. laeN� i. Dimensioned property/project boundary with bearings & distances. Ta G{j. Site Layout with all BUA identified and dimensioned.k. Existing contours, proposed contours, spot elevations, finished floor elevations.I. Details of roads, drainage features, collection systems, and stormwater control meam. Wetlands delineated, or a note on the plans that none exist. (Must be delineated byqualified person. Provide documentation of qualifications and identify the person BV; made the determination on the plans. n. Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations. o. Drainage areas delineated (included in the main set of plans, not as a separate document). Form SWU-101 Version Oct. 31, 2013 Page 4 of 6 p., Vegetated buffers (where required). ,9: Copy of any applicable soils report with the associated SHWT elevations (Please identify elevations in addition to depths) as well as a map of the boring locations with the existing elevations and boring logs. Include an 8.5"xll" copy of the NRCS County Soils map with the project area clearly delineated. For projects with infiltration BMPs, the report should also include the soil type, expected infiltration rate, and the method of determining the infiltration rate. (Infiltration Devices submitted to WiRO: Schedule a site visit for DEMLR to verify the SHWT prior to submittal, (910) 796-7378.) 10. A copy of the most current property deed. Deed book: 7 Page No: 18 11. For corporations and Limited liability corporations (LLC): Provide documentation from the NC X14 Secretary of State or other official documentation, which supports the titles and positions held by the persons listed in Contact Information, item la, 2a, and/or 3a per 15A NCAC 2H.1003(e). The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State, otherwise the application will be returned. hgp://www.secretaly.state.nc.us/Corl2orations/CSearch.aVx VIL DEED RESTRICTIONS AND PROTECTIVE COVENANTS For all subdivisions, outparcels, and future development, the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot. If lot sizes vary significantly or the proposed BUA allocations vary, a table listing each lot number, lot size, and the allowable built -upon area must be provided as an attachment to the completed and notarized deed restriction form. The appropriate deed restrictions and protective covenants forms can be downloaded from http://portal.ncdenr.org/web/ir/state-stormwater- forms does. Download the latest versions for each submittal. In the instances where the applicant is different than the property owner, it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded. By the notarized signature(s) below, the permit holder(s) certify that the recorded property restrictions and protective covenants for this project, if required, shall include all the items required in the permit and listed on the forms available on the website, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DEMLR, and that they will be recorded prior to the sale of any lot. V III. CONSULTANT INFORMATION AND AUTHORIZATION Applicant: Complete this section if you wish to designate authority to another individual and/or firm (such as a consulting engineer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional information). Consulting Engineer: Daryl Riggins, PE Consulting Firm: McAdams Mailing Address: 2905 Meridian Parkway City: Durham State: NC Zip: 27713 Phone: (919 ) 361-5000 Emaii:riggins@mcadamsco.com Fax: (919 ) 361-2269 IX. PROPERTY OWNER AUTHORIZATION (if Contact Information, item 2 has been filled out, complete this section) I, (print or hype name of person listed in Contact Information, item 2a) , certify that I own the property identified in this permit application, and thus give permission to (print or type name of person listed in Contact Information, item la) with (print or hype name of organization listed in Contact Information, item la) to develop the project as currently -proposed. A copy of the lease agreement or pending property sales contract has been provided with the submittal, which indicates the party responsible for the operation and maintenance of the stormwater system.Cl� • ,CIE 1ANis201a Form SWU-101 Version Oct. 31, 2013 Page 5 of 'As the legal property'owner f acknowledge, understand, and agree by my signature below, that if my designated agent (entity listed in Contact Information, item 1) dissolves their company and/or cancels or defaults on their lease agreement, or pending sale, responsibility for compliance with the DEMLR Stormwater permit reverts back to me, the property owner. As the property owner, it is my responsibility to notify DEMLR immediately and submit a completed Name/Ownership Change Form within 30 days; otherwise I will be operating a stormwater treatment facility without a valid permit. I understand that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statue 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $25,000 per day, pursuant to NCGS 143-215.6. , Signature: Date: I, a Notary Public for the State of County of do hereby certify that personally appeared before me this _ day of and acknowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, SEAL My commission X. APPLICANT'S CERTIFICATION 1, (print or type name of person listed in Contact Information, item In) Mark Morgan certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of the applicable stormwater rules under 15A NCAC 2H ,1000 and any other applicable state stormwater requirements. Signature: /�/� ///L= �I Date:1�/ 1, -zyyC nd- si Me ((JMCier a Notary Public for the State of County of do hereby certify that /! {4 tk el OQ w personally appeared efore me thisday of �` ,n r , ObLf,an� c n ledge the due exec o of the application for a stormwater permit. Witness my hands my hand and official seal, �1/e(C!iJ SEAL My commission expires Z- 3- 2w/4 P CA R O``�- ECF-IVE� 1AN 9 6 2010 BY:_ --- Form SWU-101 Version Oct. 31, 2013 Page 6 of SUPPLEMENT-EZ FORM COVER PAGE Please indicate the types, quantities and locations of SCMs that will be used on this project: I Quantity I Location(s) Infiltration System Bioretention Cell I Wet Pond 1 1 north of Hamilton Drive between N MacMillan Ave and Hurst Drive Sloomwater Wetland Permeable Pavement Sand Filter Rainwater Harvesting Green Roof Level Spreader -Filter Strip Disconnected Impervious Surface Treatment Swale Dry Pond Designer information for this project: Name and Title: Daniel Perry, PE Organization: JMcAdams Street address: 2905 Meridian Parkway City, State, Zip: Durham, INC 27713 Phone number(s): (919) 361-5000 Email: dperry@mcadamsco.com Designer 2�PQF E S S/0 1. 'SEAL 9� 045425 F PAP, .GINEE�•••�, Signature of Designer Z /13 //8 Date Applicant: Project Name: UNCW Hurst Hamilton Parking Lots Address 601 South College Road City / Town Wilmington, NC CnNra mr ouaury Company: UNC Wilmington Contact: Mark Morgan/Assoc. Vice Chancelor of Business Affairs Mailing Address: 601 S. College Road City, State, Zip: Wilmington, NC 28403 Phone number(s): (910) 962-3761 Fax: (910) 962-7140 Email: morganm@uncw.edu Certification Statement: I certify, under penalty of law: that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; - that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. I am aware that there are significant penalties for submitting false information including the possibility of fines and imprisonment for knowing violations as well as a report being made to my professional board. FEB 141118 By: - Cover Page 1 3:36 PM 2/9/2018 3 03:x WET POND UNCW Hurst Hamilton Parkino Lots THE DRAINAGE AREA 1 Drainage area number / Break down of BUA in the drainage area (both new and existing): Total coastal wetlands area (sq ft) - Parking / driveway (sq ft) 492710 sf Total surface water area (sq fl) - Sidewalk (sq ft) 100970 at TOW] drainage area (sq ft) 1218903 sf - Roof (sq ft) 14609 sf BUA associated with existing development (sq ft) 406445 at - Roadway (sq ft) Proposed new BUA (sq h) 201844 sf - Other, please speedy in the comment box below (sq ft) Percent BUA of drainage area 49.90% Total BUA (sq ft) 608289 sf COMPLIANCE WITH THE APPLICABLE STORMWATER PROGRAM Stormwater programs) that apply (please specify): Design rainfall depth (in) 1.5 in 1995 Rules, Session Law 2006246, Session Law 2008-211, and 2017 Rules Minimum volume required (cu ft) 61573 d Design volume of SCM (a. R) 66951 d GENERAL MDC FROM 02H .1050 #1 Is the SCM sized to treat the SW from all surfaces at build -out? Yes #7 If applicable, with the SCM be cleaned out after construction? Yes #2 Is the SCM located on or near contaminated soils? No #8 Does the mainetenance access comply with General MDC (8)? Yes #3 What are the side slopes of the SCM (H:V)? 31 #9 Does the drainage easement comply with General MDC (9)? Yes #3 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No #10 If the SCM is on a single family lot, tices the plat comply with General MDC (10)? W Are the inlets, outlets, and receiving stream protected from erosion (10-year stom)? Yes #11 Is there an 08M Agreement that complies with General MDC (11)? Yes #5 Is there a a bypass for flows in excess of the design flow? Yes 012 Is there an 08M Plan that complies with General MDC 12)? Yes #6 What is the method for dewatedng the SCM for maintenance? Pump (preferred) 913 Was the SCM designed by an NC licensedprofessional? Yes WET POND MDC FROM 02H .1053 #1 Method used SA/DA #6 Width of the vegetated shelf (tees) 60 It #1 Surface area of the main permanent pool (square feet) 31275 at #6 Location of vegetatetl shell Above Normal Pool Al Volume of the main permanent pool (cubic feet) 178984 d #6 Elevation of top of shelf (fmsl) 34,30 If 02 Average depth of the main pool (feet) 5.72It #6 Elevation of bottom of shell final 33.30 ft #2 Was the vegetated shelf included in the calwlalion of average depth No #6 Slope of vegetated shelf (H:V) 6:1 #2 Elevation of the bottom of the permanent pool (fmsl) 26.00 in #7 Diameter of drawdown onfice (inches) 4.00 in #2 Elevation of the top of the permanent pool (fmsq 33.30 in #7 Drawdown time for the temporaypool (hours) 77.28 hrs #2 Elevation of the top Of the temporary pool fmsq 34,30 in #1 Does the onfice drawdowa from below the top surface of the permanent pool? Yes #3 Depth providecl for sediment storage (inches) fi 0 in #8 Does the pond minimize impacts to the receiving channel from the 1-yr. 24-hr storm? Yes #4 Are the inief(s) and outlet located in a manner that avoids short-ciraiting? Ves #9 Are fountains proposed? No #4 Describe any measures, such as berms or baffles , that will be taken to improve the flow path' #9 If yes, is documentation provided per Wet Pond MDC (9)1 A forebay weir spillway is located between the forebay and main pool to increase the Flow path from inlet to outlet. #10 Is a fresh rack or other device provided to protect the outlet system? Yes #5 Volume of the forebay (cubic feet) 76418 #11 Are the dam and embankment planted in non -dumping turf grass? Yes #5 Is this 15-20% Of the volume in the main pool? No #11 Species of turf that will be used on the dam and embankment c Z.n eemmapiass #5 Depth Of forebay at entrance (inches) 69.6 in #11 Descibe the planting plan for the vegetated shell: #5 Depth of forebay at exit (inches) 15.6 in The vegetated shelf will be planted with six species: Joe Pye Weed, Scarlet Rose Mallow, Seashore Mallow, Woolgrass, Giant Cutgrass, and Blue Flag Ins. All species will be planted at 24" O.C. at a minimum density of 50 plants per 200 sf. #5 Does water Dow out of the forebay in a non -erosive manneR Yes #5 Clean -out depth for forebay (inches) 63.6 in #5 Will the tomboy be cleaned out when the depth is reduced to less than the above? Yes ADDITIONAL INFORMATION Please use this space to provide any additional information about this wet pond that you think is relevant to the review: It should be noted that this SCM was previously constructed and therefore is undergoing modification to accomdate proposed development and meet cuff ant design standards. As such, the existing dam embankment will remain with modified grading only occurring internally. The forebay percentage exceeds the volume requirement for forebay requirement staled in the MDCs, which is primarily due to the volume contrbuted by the existing forebay across Hurst Drive that is remaining unaltered as a part of this project. E^ C I V L DepthDepth ProposedForebayF #2 Y entrance 27.6 in lid' Depth of Proposed Forebay n2 at exit 2].6 in Cleanout Depth of Proposed Forebay #2 45.6 in •Extuhng Fo boy is not being rrwdified m port of this project* Depth of Existing Forebay at entrance 51.6 in Depth of Existing Forebayat exit 51.6 in BY: Cleanout Depth of Existing Forebay 36.6 in Wet Pond 2 3:36 PM 2/9/2018 MEMORY TRANSMISSION REPORT TIME :02-23-2018 14:04 FAX NO.1 :9103502004 NAME :Mainfax FILE NO. 648 DATE 02.23 14:00 TO :n 99627140 DOCUMENT PAGES 17 START TIME 02.23 14:01 END TIME 02.23 14:04 PAGES SENT 17 STATUS OK MEMORY TRANSMISSION REPORT TIME :02-23-2018 14:05 FAX NO.1 :9103502004 NAME :Mainfax FILE NO. 649 DATE 02.23 14:01 TO :n 919193612269 DOCUMENT PAGES 17 START TIME 02.23 14:04 END TIME 02.23 14:05 PAGES SENT 0 STATUS 0050 Hall, Christine From: Hall, Christine Sent: Monday, February 19, 2018 5:10 PM To: 'Perry, Daniel' Cc: Stubbs, Rebecca; Riggins, Daryl Subject: RE: [External] Hurst Hamilton Parking Lot (SW8 060S30) Thank you for the clarification. I have finished the review and found one more thing. The response to item 2.1b and the revised calculations no longer considers the two proposed forebays independently. When this item was discussed on the phone, I thought it was clear that each forebay had to demonstrate that it was sized to handle 15-20 % of its contributing drainage area or justification for the variation had to be provided per.1003(6). Third requests for additional information are not generally granted but... Please provide calculations identifying the individual proposed forebay size respective to its contributing drainage area and if necessary, provide justification for any variation to the MDC. Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct christine.hall@ncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 Nothing Compares..,,. A' Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Perry, Daniel [mailto:dperry@mcadamsco.com] Sent: Monday, February 19, 2018 3:57 PM To: Hall, Christine <Christine.Hall@ncdenr.gov> Cc: Stubbs, Rebecca <rstubbs@mcadamsco.com>; Riggins, Daryl <riggins@mcadamsco.com> Subject: RE: [External] Hurst Hamilton Parking Lot (SW8 060530) o External email: Do not dick Imks or open attachments unless verified. Send all suspicious email as an attachment to, , 'xd Hi Christine, The calculations attached to the response are associated with the existing condition of the facility to show how the current SCM grading shakes out with the MDC methodology. The calculations in the book are what you should be reviewing for the proposed condition. Sorry for the confusion. Thank you, Daniel Perry, PE I Project Manager, Water Resources McAdams 2905 Meridian Parkway, Durham, NC 27713 office 919. 361, 5000 x134 [ direct 919. 287 www.mcadamsco.com [ linkedin I twitter 2 MCA DAMS creating eiperiences through experience 0795 [ mobile 919. 614.6212 1 dperrvPmcadamsco.com instaeram I join our team From: Hall, Christine[ma IIto:Christine.Hall@ncdenr.PovI Sent: Monday, February 19, 2018 3:47 PM To: Perry, Daniel <dperry@mcadamsco.com> Cc: Stubbs, Rebecca <rstubbs@mcadamsco.com>; Riggins, Daryl <riggins@mcadamsco.com> Subject: RE: [External] Hurst Hamilton Parking Lot (SW8 060530) I've started looking at the requested information received on 2/14 for this project and am a bit confused by the pond sizing calculations. Why are the calculations attached to the response letter different than the ones in the binder? Which set is correct? Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct christine. hall()ncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 Nothing Compares._ Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Perry, Daniel [mailto:dperry@mcadamsco.com] Sent: Friday, February 09, 2018 1:37 PM To: Hall, Christine <Christine.Hall@ncdenr.gov> Cc: Stubbs, Rebecca <rstubbs@mcadamsco.com>; Riggins, Daryl <riggins@mcadamsco.com> Subject: RE: [External] Hurst Hamilton Parking Lot (SW8 060530) Much appreciated! Have a great weekend! Daniel Perry, PE I Project Manager, Water Resources I . Hall, Christine From: Perry, Daniel <dperry@mcadamsco.com> Sent: Thursday, February 22, 2018 4:09 PM To: Hall, Christine Cc: Stubbs, Rebecca, Riggins, Daryl Subject: RE: (External] Hurst Hamilton Parking Lot (SW8 060530) Attachments: Narrative.pdf, SWMF-MDC-WQ Pond Calcs-POST.PDF u External email. Do not click links or open attachments unless ver fled Send all stuspiaous email as an attachment to Re ort5a Christine, Thank you for your phone call and clarification yesterday. See attached for an updated narrative and the WQ Pond Calc Sheet showing the forebay calculatoins. Thanks for your help! Daniel Perry, PE I Project Manager, Water Resources McAdams 2905 Meridian Parkway, Durham, NC 27713 office 919, 361. 5000 x134 I direct 919. 287. 0795 1 mobile 919. 614.6212 1 dperry@mcadamsco.com www.mcadamsco.com I linkedin I twitter I instagram.I join our team 21 MCADAMS creating experiences through experience From: Hall, Christine[mailto:Christine.Hall@ncdenr.gov] Sent: Monday, February 19, 2018 5:10 PM To: Perry, Daniel <dperry@mcadamsco.com> Cc: Stubbs, Rebecca <rstubbs@mcadamsco.com>, Riggins, Daryl <riggins@mcadamsco.com> Subject: RE: [External] Hurst Hamilton Parking Lot (SW8 060530) Thank you for the clarification. I have finished the review and found one more thing. The response to item 2.b and the revised calculations no longer considers the two proposed forebays independently. When this item was discussed on the phone, I thought it was clear that each forebay had to demonstrate that it was sized to handle 15-20 % of its contributing drainage area or justification for the variation had to be provided per .1003(6). Third requests for additional information are not generally granted but... Please provide calculations identifying the individual proposed forebay size respective to its contributing drainage area and if necessary, provide justification for any variation to the MDC. Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct christine.hall(o)ncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 'Nothing Compares Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Perry, Daniel Imailto:dperry@mcadamsco.com] Sent: Monday, February 19, 2018 3:57 PM To: Hall, Christine <Christine.HaII@ncdenr.Pov> Cc: Stubbs, Rebecca <rstubbs@mcadamsco.com>; Higgins, Daryl <riagins@mcadamsco.com> Subject: RE: [External] Hurst Hamilton Parking Lot (SW8 060530) o External email. Do not click links or open'attachments unless verified. Send all suspicious email4as,3an attacment keport Spam. ' �P.1 u `t"w Hi Christine, The calculations attached to the response are associated with the existing condition of the facility to show how the current SCM grading shakes out with the MDC methodology. The calculations in the book are what you should be reviewing for the proposed condition. Sorry for the confusion. Thank you, Daniel Perry, PE I Project Manager, Water Resources McAdams 2905 Meridian Parkway, Durham, NC 27713 office 919. 361. 5000 x134 I direct 919. 287. 0795 1 mobile 919. 614.6212 1 dperrv@mcadamsco.com www.mcadamsco.com I linkedin I twitter I instagram I loin our team 0 MCADAMS creating experiences through experience From: Hall, Christine[mailto:Christine.Hall@ncdenr.gov] Sent: Monday, February 19, 2018 3:47 PM To: Perry, Daniel <dperrv@mcadamsco.com> Cc: Stubbs, Rebecca <rstubbs@mcadamsco.com>; Riggins, Daryl <riggins@mcadamsco.com> Subject: RE: [External] Hurst Hamilton Parking Lot (SW8 060530) I've started looking at the requested information received on 2/14 for this project and am a bit confused by the pond sizing calculations. Why are the calculations attached to the response letter different than the ones in the binder? Which set is correct? Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 2 MCADAMS Date: February 13,2018 To: Ms. Christine Hall Department of Environmental Quality 127 Cardinal Drive Extension Wilmington, North Carolina 28405 I am sending you the following items: ❑ Drawings ❑ Letter ❑ Specifications ® Submittal ❑ Plans ❑ Prints LETTER OF TRANSMITTAL FEDERAL EXPRESS Re: Hamilton Hurst Parking Lot 3rd Express Review Submittal Job #: UNW-17060 ❑ Statement of Qualifications ❑ Other QUANTITY UNIT DESCRIPTION 1 Copy Response to Comments Letter i Copy Stormwater Management Plan 1 Copy SCM Supplement Form —Original 1 Copy O&M Manual 1 Copy Permit Application 2 Copies Construction Drawings Transmitted as checked below: M For approval ❑ For your use ❑ As requested Remarks: Copy to: M For review + comment ❑ Other ❑ Other Project Manager, Institutional PE creating experiences through experience 2905 Meridian Parkway, Durham, NC 27713 / 919. 361. 5000 2 MCA DAMS February 13, 2018 State of North Carolina Environmental Quality, Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 RE: Hurst Hamilton Parking Lots Stormwater Project No. SW8 060530 Request for Additional Information UNW-17060 RESPONSE TO COMMENTS > UNW-17060 The following are the response comments for the above -mentioned project. Our response comments are in bold. NCDEQ: Christine Hall, Environmental Engineer 910.796. 7215 1. 15A NCAC 02H.1042(2)(g)(iv): Please provide additional proposed contours on sheets C10 and C11 to support the identified drainage areas and patterns in the following areas: a. The intersection of Hurst Drive and Hamilton Drive. McAdams Response: Countour labels have been added to clarify the drainage area in this location. Since no changes were made to this area of the site relating to this project, the drainage area remains consistent with the previously approved permit. b. The sidewalk high point off McMillan Ave near the pump station. McAdams Response: The drainage area has been revised around the electric substation. Contour labels have been provided on the existing topo and spot shots provided on the sidewalk as it meets MacMillan Ave to better clarify drainage patterns in this area. c. The west parking lot access drive on McMillian Ave. McAdams Response: The draiage area has been revised and contours labels added to the proposed grading in this area. ECEW'1 FEB 142019 H BY - creating experiences through experience 2905 Meridian Parkway, Durham, NC 27713 / 919. 361. 5000 J MCADAMS RESPONSE TO COMMENTS > UNW-17060 2. 15A NCAC 02H.1053(5):. a. The sum of the forebay drainage areas presented in the calculations is less than the total drainage area to the pond. Please explain the difference. McAdams Response: There are some areas within the overall drainage area to the SCM that overland flow into the Main Pool. The size of these areas has been reduced from the existing condition in the proposed layout, as all concentrated discharges resulting from the proposed development are directed into one of the forebays to receive pretreatment prior to entering the main pool portion of the SCM. b. In reviewing the calculations for sizing the individual forebay volumes, it appears that each of the three forebays (existing and proposed) exceed 20% of its area weighted volume in the main pool. 15A NCAC 02H.1053(5)(a) requires the forebay volume to be 15 to 20% of the volume in the main pool. Please either reconsider the size of the three forebays or provide justification for the variations in accordance with 15A NCAC 02H.1003(6) McAdams Response: The forebay volume provided in the SCM is in excess of the 15-20% required volume. The existing forebay which will remain unaltered, was previously approved with a forebay volume in excess of 20%. Attached to this reponse you will see modified calculations showing the forebay volume of the existing forebay calculated per MDC guidance to be 52.7%. As a part of this project, additional concentrated discharges to the SCM were required. At each of these points, a forebay of proportional size was provided to allow for appropriate sediment dropout. The proposed forebays provide a volume within the 15-20% requirement per the MDCs. This is in addition to the volume provided by the existing forebay. Therefore, in total, the forebay volume well exceeds the MDC requirement, providing better opportunity got sediment dropout prior to entering the main pool. The surface area of the main pool remains oversized, providing better treatment of stormwater runoff directed to this SCM. Please see the attachment to this letter to show the existing forebay % converted to MDC calculation methodology. 3. 15A NCAC 02H.1003(1)(b): In Attachment A, the exisiting, pre-1988 built upon area is not included in the total BUA for the site. Please demonstrate that the project area used for this drainage area meets either 15A NCAC 02H.1003(1)(a) or .1003(1)(b). McAdams Response: The project area was determined using the method described in iSA NCAC 02H .1003 (1)(b). The existing, pre-1988 BUA in the "Drainage Area LOW DENSITY" portion of this permit was subtracted from the total BUA and divided by the total project area within that drainage area minus the pre-1988 BUA, to determine project density. A calculation has been provided at the bottom of Attachment A, please refer to that document for more detail. 4. Due to the relatively minor nature of these comments, the express additional information review fee has been waived. McAdams Response: Thank you. creating experiences through experience 2 of 2 MCADAMS RESPONSE TO COMMENTS > UNW-17060 Consideration of this response is greatly appreciated. If you should have any questions or require additional information, please do not hesitate to contact me at 919. 361. 5000. Sincerely, MCADAMS Daniel Perry, PE Project Manager, Water Resources DP/ca creating experiences through experience 3 of UNCW HURSTHAMILTON PARKING LOT STORMWATER CONTROL MEASURE UNW-17060 SSFxn Above NP STAGE -STORAGE FUNCTION -ABOVE NORMALP00L Average Incremental Accumulated Estimated Contour Contour Contour Contour Stage Contour Stage Area Area Volume Volume w/S-S Fxn (feet) (feet) (SF) (SF) (CF) (CF) (feet) 33.30 0.00 53925 34.00 0.70 60103 57014 39910 39910 0.73 35.00 1.70 69180 64642 64642 104551 1.58 36.00 2.70 115911 92546 92546 197097 2.65 37.00 3.70 127573 121742 121742 318839 3.91 Storage vs. Stage 350000 300000 - y = 59243x' zasa 250000 R' = 0.9939 LL U 200000 m 0 150000 V 100000 50000 0 0.00 1.00 2.00 3.00 4.00 Stage (feet) Ks = 59243 b = 1.2353 Average Incremental Accumulated Estimated 1 Contour Contour Contour Contour Stage Contour Stage Area Area Volume Volume w/S-S Fxn (feet) (feet) (SF) (SF) (CF) (CF) (feet) 33.30 0.00 34425 34.00 0.70 38234 36330 25431 25431 0.50 35.00 1.70 43642 40938 40938 66369 1.10 37.00 3.70 132966 96328 96328 214363 2.83 Average Incremental Accumulated Estimated I Contour Contour Contour Contour Stage Contour Stage Area Area Volume Volume w/S-S Fxn (feet) (feet) (SF) (SF) (CF) (CF) (feet) 33.30 0.00 19500 34.00 0.70 21869 20684 14479 14479 0.32 35.00 1.70 25S38 23704 23704 38183 0.70 36.00 2.70 56221 40880 40880 79062 1.26 37.00 3.70 70420 63321 63321 142383 2.03 R. STUBBS, El 2/9/2018 ��CE1VE ` --j FEB 14 2" UNCW HURSTHAMIJON PARKING LOT STORMWATER CONTROL MEASURE R. STu88S, El UNW-17060 SSFxn Main Pool 2/9/2018 STAGE -STORAGE FUNCnON NIAIN'POOL Average Incremental Accumulated Estimated Contour Contour Contour Contour Stage Contour Stage Area Area Volume Volume w/S-S Fxn (feet) (feet) (SF) (SF) (CF) (CF) (feet) 26.00 27.00 -1.00 0.00 2,763 4,048 Sediment Storage 28.00 1.00 5,499 4774 4774 4774 1.11 29.00 2.00 7,338 6419 6419 11192 1.89 30.00 3.00 9,823 8581 8581 19773 2.70 31.00 4.00 14,433 12128 12128 31901 3.64 32.00 5.00 24,189 19311 19311 51212 4.90 33.00 6.00 32,793 28491 28491 79703 6.46 33.30 6.30 1 34,425 33609 10083 89,785 6.97 'surface area and volume used for avg. depth calculation 100000 90000 Storage vs. Stage 80000 70000 Y = 4056.5x' sass R' = 0.9817 p 60000 50000 0 40000 u 30000 20000 10000 0 2.00 4.00 6.00 8.00 0.00 Stage (feet) Ks = 4056 b = 1.5956 UNCW HURSTHAMILTON PARKING LOT STORMWATER CONTROL MEASURE R. STUBBS, El UN W-17060 SSFxn Foreboy 2/9/2018 'STAGE-STORAGE'FUNCTION=:FOREBAY Estimated Average Incremental Accumulated j Contour Contour Contour Contour Stage Contour Stage Area Area Volume Volume w/S-S Fxn (feet) (feet) (SF) (SF) (CF) (CF) (feet) 29.00 -1.25 9,132 Sediment Storage 30.25 0.00 11,872 30.50 1.50 12,442 12157 3039 3039 1.38 31.00 2.00 13.603 13023 6511 9551 2.1R 32.00 3.00 16,021 14812 14812 24363 3.17 33.00 4.00 18,557 17289 17289 41652 3.92 33.30 4.30 19,500 19028 5708 47360 4.13 60000 50000 Storage vs. Stage y = 1343.5x2.5132 R2 = 0.9771 -- 40000 U rn 30000 m `o H 2O000 10000 0- 1.00 2.00 3.00 4.00 5.00 0.00 Stage (feet) Ks = 1343.5 b = 2.5132 FES 14 201a UNCW HURST HAMILTON PARKING LOT STORMWATER CONTROL MEASURE UN W-17060 Volume Calculation R. STUBBS, El 2/9/2018 (TOTAL VOLUME OF FACILITY Volume of Main Pool below Normal Pool= 89,785 cf Volume of Forebay below Normal Pool= 47,360 cf Total Volume Below Normal Pool = 137,145 cf Total Volume Above Normal Pool= 318,839 cf Total Volume of Facility= 455,984 cf FOREBAY PERCENTAGE OF PERMANENT POOL VOLUME Per NCDEQ Minimum Design Criteria, the forebay volume should equal approximately 15-20% of the main pool volume. Total Main Pool Volume = 89,785 cf Provided Forebay Volume = 47,360 cf Provided Forebay Volume %= 52.7% AVERAGE DEPTH OF MAIN POOL Volume of Main Pool at Permanent Pool = 89,785 cf Surface Area of Main Pool at Permanent Pool = 34,425 sf Average Depth = 2.61 ft FEB 14 2018 UNC WILMINGTON HURST HAMILTON PARKING LOTS WILMINGTON, NORTH CAROLINA STORMWATER MANAGEMENT PLAN PROJECT NUMBER: DESIGNED BY: DATE U N W-17060 DANIEL PERRY, PE REBECCASTUBBS, El FEBRUARY 2018 MCADAMS 2905 MERIDIAN PARKWAY DURHAM, NORTH CAROLINA 27713 INC Llc. # C-0293 'mc;F-1*46 FEB 14 2o�a BY:---- CAss l/ L 9� .9 ...1d .... ; • Od2d52 = CEvr 5p`OtE22... �y 't016111W, TI MCADAMS General Description NARRATIVE > UNW-17060 UNC WILMINGTON — HURST HAMILTON PARKING LOTS Stormwater Management Plan Located at the intersection of Hurst Drive and Hamilton Drive, the Hurst Hamilton Parking Lots project will consist of two (2) surface parking lots providing a total of +/- S74 spaces to accommodate visitors and students. The proposed lots are anticipated to contain one entrance off Hurst, one exit onto Hamilton, and one two-way access to N. MacMillan Drive. The project will include the addition of bike parking stalls, a bus shelter, along with a modification to an existing, adjacent SCM (i.e. the Lot K pond). The proposed project will be high density and will require a major modification to the existing State Stormwater Management Permit (SW8 060530) In this area of the UNCW campus. The addition of the surface parking lots will require an expansion to the existing SW8 060530 permit boundary. To better mimic the true drainage area to the Stormwater Control Measure (SCM), the modified permit boundary will now Include existing BUA that has been reviously unaccounted for, meaning that the SCM will be designed to provide equal or better treatment for the net mcrease in BUA for this modified permit boundary. The amount of existing BUA that will now receive treatment credit from the SCM is greater than the proposed amount of Impervious bypassed from the small proposed parking lot along acMillan Ave. Additional impervious outside of the drainage area to the SCM has been calculated to remain under the low -density threshold of 24% for the rernalning portion of the permit boundary. Please refer to the BUA map included in section 4 of this report. The existing Lot K pond will be renovated / expanded to accommodate the proposed increase In impervious area. As a result of the increase in BUA and expansion of the existing SCM, the wet pond design will be modified to meet NC DEQ's Minimum Design Criteria. The project is located within the Cape Fear River Basin, with stonnwater runofffrom the proposed project draining to Burnt Mill Creek. According to the N.C. Division of Water Quality BasinWide Information Management System (BIMS), the waterway is classified as C; Sw" at this location (Stream Index M 18-74-63-2). Calculation Methodology Rainfall data for the Wilmington, NC region is from NOAA Atlas 14. This data describes a depth -duration - frequency (DDF) table describing rainfall depth versus time for varying return periods in the Wilmington, NC area. These rainfall depths are input into the meteorological model within PondPack for peak flow rate calculations. Please reference the miscellaneous site information section within this report for additional information. Using maps from the NRCS Web Soil Survey, the on- and off -site soils were determined to be from hydrologic soil group (HSG) 'A' soils, 'B' soils and 'D' soils. Since the method chosen to compute both pre- and post - development peak flow rates and runoff volumes is dependent upon the soil type, care was taken when selecting the appropriate Soil Conservation Number (SCS CN). For this analysis, the HSGs for the site consisted of'A'.'B'. and'D', Within the site boundary, an approximate proportion of each soil group was determined using NRCS Web Soil Survey. Once an approximate proportion was determined, a composite SCS CN was computed for each cover condition. • Land cover conditions for the site were taken from a recent aerial mapping survey prepared b w e Inc and combined with ground truth survey prepared by Atlantic Coast Survey. Ell FEB 2 2 2018 creating experiences through experience 2905 Meridian Par6y;-DurharK Nr7g'is. 36i. 5000 iJ MCADAMS NARRATIVE > UNW-17060 The times of concentration are calculated using the SCS TR-55 Segmental Approach, The To flow paths are divided into three segments: overland flow, concentrated flow, and channel flow. The travel time is then computed for each segment, from which the overall time of concentration is determined by taking the sum of each segmental time. PondPack Version VSi, by Bentley Systems, Inc., was used in determining the pre- & post - development peak flow rates for the 1-, 2-, 10-, 25- and 100-year storm events, as well as routing calculations for the modified stormwater management facility. • The drainage ditches along Hamilton Drive and MacMillan Avenue were modeled as Interconnected ponds with the existing SCM and with its proposed modifications. The ditches provide a significant amount of storage to the watershed and therefore their stage storage function was determined using best available survey data. • There are three proposed driveway culverts for entrances to the proposed parking lots. One along Hamilton Drive and two along MacMillan Avenue. The driveway culverts were sized such that the interconnection of ponds would balance the water surface elevation of the roadside ditches with the SCM. There is an existing culvert under the driveway to existing substation off of MacMillan Avenue that was modeled, and performance verified In throughout this analysis. ( 1 • The offsite drainage area from the adjacent apartment complex was assumed to be full build -out in the calculation of impervious area to the SCM. If new development were proposed for the site, a 20' setback mentioned in the ordinance would be required similar to that currently provided for this property; therefore, this development has reached Its impervious threshold which could drain to the SCM. • There is an existing 42" RCP culvert at the intersection of S College Rd and MacMillan Ave that was used as the overall point of analysis In the existing and proposed scenarios of the drainage ditches and SCM. This culvert was modeled with a tallwater condition to match crown of pipe to be conservative in the analysis of conveyance through the pipe. • The existing forebay of the wet detention basin will not be modified and therefore was modeled with the same stage storage function in both the existing conditions analysis and the proposed modifications analysis. To provide an accurate analysis of current conditions of the existing forebay, a stage storage function was generated from survey prepared by Avioimage. It is acknowledged that the forebay percentage in the proposed build -out condition exceeds the volume requirement for forebays stated in the MDCs. The existing forebay which will remain unaltered, was previously approved with a forebay volume in excess of 20%. As a part of this project, additional concentrated discharges to the SCM were required. Project elements such as location of the concentrated discharges and physical shape of the SCM influenced the size and location of the proposed forebays. For instance, Proposed Forebay #1. utilizes a berm that will be constructed as part of the construction access to the west lot and will be converted to a permanent forebay berm for the lifetime of the SCM. Additionally, a large forebay in this location is more effective to capture the concentrated discharges from both inlets draining the east parking lot. Proposed Forebay #2 also exceeds the 20% requirement, however, it was in the engineer's opinion that a smaller forebay than what was designed would not be as constructible and may require more frequent sediment cleanouts. Each of the forebays provided are proportional in size to the drainage areas directed to them. This Is in addition to the volume provided by the existing forebay, therefore in total the forebay volume well exceeds the MDCs requirement. The surface area of the main pool remains oversized, providing better treatment of stormwater runoff directed to this SCM. \ �'"�` 'The existing:obtlet structure will remain, with modifications to account for additional water quality volume Q storage. The ouflet structure information was provided to the John R. McAdams company by survey perfor med .4 creating experiences through experience - 2905 Meridian Parkway. Durham, NC 1919. 361. 5000 gill MCADAMS NARRATIVE > UNW-17060 by Atlantic Coast Survey. It is important to note that between the as -built survey conducted In 2006 and the survey performed by Atlantic Coast survey in 2017, the reference datum was adjusted from NAVD29 to NAVD88. This datum shift accounts for the discrepancies in elevation information between the as -built survey and the current project survey of the outlet structure. Conclusion If the development on this tract is built as proposed within this report, then the applicable requirements will be met with the proposed storinwater management facility. However, modifications to the proposed development may require that this analysis be revised. Some modifications that would require this analysis to be revised include: 1. The proposed site impervious surface exceeds the amount accounted for In this report. 2. The watershed breaks change significantly from those used to prepare this report. The above modifications may result in the assumptions within this report becoming invalid. The computations within this report will need to be revisited if any of the above conditions become apparent as development of the proposed site moves forward. EGEI V IG FEB 2 2 2018 BY: _ --- creating experiences through experience 2905 Meridian Parkway. Durham, NC / 919. 361. 5000 Permit: SW8060530 ATTACHMENT A z/u/zole Project Number: UN W-12060 0r0inoge Area/Impervious Breakdown Basin Information Drainage AreatoKM REDEVELOPMENT EXEMPTION Drainage Area LOW DENS" Drainage Area TOTAL Receiving Stream Name Burnt Mill Creek Burnt Mill Creek Burnt Mill Creek Stream Class CSw C;Sw CSw Stream Index Number 18-74-63-2 18-74-63 2 I8-74-63 2 Total Oralnage Area ls_fi 1,218,903 14,555 139,687 1,373,145 On-SW8060530&On-UNCW PropeM Drain age Are.(sf) On-SW8060530&Off-UNCW PropeM Drainage Area (If) Off -SW8060530 &On UNCW Property Drainage Area(sfl 1,030,146 14,555 121,413 1,166,114 6,029 3,566 9,645 144,959 0 144,959 Off-SW8060530&Off-UNCW PmpeM Drainage Area is_f) 37,219 0 33,719 ROW Drainage Area (0) 0 14,208 14,708 Total stationed Impervious Area isfi 608,289 14,555 25,145 647,999 On-SW8060530 Proposed Impervious Area 575,153 14,555 1919,746 608,520 ROW Proposed lmperylous Area 0 - 5,399 5,399 TOG[%Impervious Area 49,90% 1C0.00% 1&00% 47.19% 0nSW8050530%lmteryioun Area 55.5014 100.00% 15.80% 52.18% ROW% Impervious Area 36]3% 36.71% Impervlous Surface Area Drainage Area to KM REDEVELOPMENT EXEMPTION Drainage Area LOW DENSITY Drainage Area TOTAL 0n site SW8060530 Buildings/LOU(ntl 0 0 0 On site SW8060530 Streets isfi 0 0 0 On -site SW8060530 Parking isfi 186,959 11,600 3,228 201,787 On- site SW8060530 Sidewalks isfi 14,885 2,955 8,692 26.532 1988-2008 352,597 - 6,892 359,489 200E-2013 5,952 - 0 5,952 SW8031039 13,154 0 13,154 SWa 300405 10p28 0 10,428 Off-UNCW Property &Off-SW806053011119M 2009 (5eobowl spuore & amaN pmlm o/Cortme Rd) 9554 - 0 9,554 Off UNC IPmperty 6 On'SWB 060530 isfi 1998-2008 favoun..'Aillon Aye) 0 383 383 Off UNCW ProteM & On-sW8060530 (IN Post 2017 (ovma MaA411on Aye) 0 - 551 551 ROW (0)1988-2008 0 1,989 1,989 ROW(sQ Post 2017 O 3,410 3,410 ROW Existing Pre-19811 BUA in_f) 0 20,409 0 On-5W80W530 Existing Pre-1988 BUA (fill14,T60 1 1.806 14,760 Total(sqj 6081289 1 14,555 25,145 642,989 -This permit utilizes rear eament exemption by Imating 14,70 IT of existing Pre 19M BUA alloym, 14,555 If of proposed impervious to be bypassed' Total Drainage Area to SCM= 1,218,903 22.98 'Drainage Area LOW DENSITY' _ (Total Drainage Areal -[Existing Pre-1988 BUA[ Total "Drainage Area LOW OENSIN"= 161,902 If Total-&istmg Pre 109 BUA '= 22,215 If 'Drainage Area LOW DENSITY'= 139,682 If Total Permit Boundary Area= 1,212,682 22.94 UNCW HURST HAMILTON PARKING LOTS Attachment B R. STUBBS, El UN W-17060 SW8 060530 Permit Boundary 2/9/2018 Point 1 Northing 173614.3524 Easting 2338018.013 2 173551.6309 2337986.431 3 173523.1011 2338009.813 4 173477.8453 2338046.902 5 173457.3113 2338064.923 6 173418.3321 2 338104.22 3 7 173388.1056 2338128.879 8 173356.2498 2338151.488 9 173325.6648 2338154.02 10 173321.0007 2338165.02 11 173326.1876 2338181.018 12 173283.7679 2338211.615 13 173 228.8061 23 382 50.022 14 173202.1854 2338262.634 15 173183.9206 2338276.657 16 173162.5925 2338302.562 17 173149.1343 2338321.541 18 173128.6557 2338352.24 19 173135.7201 2 33 8363.42 2 20 173145.1592 2338374.125 21 173174.5574 2338433.889 22 173035.5778 2338650.05 23 173050.275 2338666.617 24 173086.963 2338688.792 25 173126.7 2338710.72 26 173171.15 2338735.654 27 173215.119 2338760.154 28 173246.555 2338777.688 29 173317.5487 2338816.729 30 173349.657 2338834.606 31 173394.419 2338859.493 32 173440.884 2338885.297 33 173487.276 2338911.19 34 173530.446 2338935.226 35 173574.7259 2338959.795 UNCW HURST HAMILTON PARKING LOTS Attachment B R. STUBBS, El UNW-17060 SW8 060530 Permit Boundary 2/9/2018 Point 36 Northing 173586.8484 Easting 2338965.131 37 17 3596.1651 2338955.39 38 173634.6391 2338976.854 39 173621.5874 2339002.365 40 173 656.2801 2 33 9020.57 2 41 173679.6085 2338995.677 42 173695.1705 2338964.066 43 173 704.601 2338961.913 44 173703.6307 2338982.544 45 173697.8086 2338993.625 46 173697.367 2338997.171 47 174192.1105 2339264.52 48 1742 24.4251 2339265.891 49 174247.9494 2339229.919 50 174259.5502 2339212.606 51 17427 5.2491 2339200.09 52 174283.3214 2339195.042 53 174308.32 71 2 33 9147.936 54 174271.6218 2339129.496 55 174268.2436 2339126.213 56 174265.3885 2339123.439 57 174262.4074 2339112.14 58 174263.4914 2339091.349 59 174251.5669 2339082.942 60 174257.0028 2339063.762 61 174257.2739 2339046.949 62 174267.482 2339029.05 63 174301.3921 2338990.802 64 174311.6483 2338985.671 65 174328.3896 2338986.96 66 174470.1399 2339065.248 67 174475.1628 2339055.842 68 174497.3755 2339067.553 69 174527.6788 2339015.126 70 174598.935 2338886.495 UNCW HURST HAMILTON PARKING LOTS Attachment B R. STUBBS, El U N W-17060 2/9/2018 OSWS 060530 Permit Boundary Point 71 Northing 174669.8453 2338760.735 72 174655.3846 2338752.581 73 174652.63 2338742.46 74 174672.0001 2338708.643 75 174686.8859 2338705.953 76 174680.3946 2338682.005 77 174627.6809 2338575.698 78 174561.0585 2338482.735 79 174474.0516 2338396.315 80 174381.6797 2338314.097 81 174276.3425 2338235.706 82 174188.2818 2338211.33 83 174131.8014 2338178.128 84 174107.2665 2338185.416 85 174055.9475 2338288.51 86 173995.9768 2338308.39 87 173994.1492 2338282.877 88 174006.1218 2338258.137 89 174034.1257 2338218.619 90 174048.3 241 23 38197.953 91 17407 3.5891 2338146.159 92 174122.9122 2338050.034 93 174122.2639 2338049.289 94 174071.3467 2338020.394 95 173962.3523 2337958.489 96 173877.3673 2338131.771 97 173808.2846 2338272.867 98 173917.3186 2338334.452 99 173840.7622 2338490.01 100 173621.1446 2338370.853 101 173853.6611 233789 6.7 59 102 173799.9257 2337866.242 SUMMARY OF RESULTS 1 MISCELLANEOUS SITE INFORMATION 2 PREVIOUS STATE WATER PERMITS PRE -DEVELOPMENT HYDROLOGIC 4 CALCULATIONS POST -DEVELOPMENT HYDROLOGIC 5 CALCULATIONS STORMWATER MANAGEMENT FACILITY 6 DESIGN CALCULATIONS UNCW - HURST HAM ILTON PARKING LOTS SUMMARY OF RESULTS R. STUBBS, El UNW-17060 2/9/2018 RELEASE RATE MANAGEMENT RESULTS EXISTING CONDITIONS PROPOSED CONDITIONS Ditch #1 Return Period Max WSE I Ikl I 1-Year 36.11 2-Year 36.55 10-Year 37.10 25-Year 37.22 50-Year 37.25 300-Year 37.25 Ditch #6 Return Period Max WSE Ik] I 1-Year 35.72 2-Year 36.31 10-Year 37.01 25-Year 37.06 50-Year 37.12 100-Year 37.18 Ditch #2 Return Period II Max WSE I Ihl I 1-Year 36.11 2-Year 36.55 30-Year _ 37.11 25-Year 37.24 50-Year 37.25 300-Year 37.25 Ditch #3 Return Period Max WSE I fhl � 1-Year 36.10 2-Year _ 36.53 10-Year 37.00 25-Year 37.09 50-Year 37.12 100-Year 37.14 UNCW - HURST HAM I JON PARKING LOTS SUMMARY OF RESULTS R. STUBBS, El UNW-17060 2/9/2018 ORELEASE RATE MANAGEMENT RESULTS EXISTING CONDITIONS Ditch R7 Return Period Max WSE [hl 1-Year 35.72 2-Year 36.30 10-Year 36.63 25-Year 36.78 50-Year 36.89 100-Year 36.93 Pre-Forebay Return Period Max. WSE [el Freeboard) Ikl 1-Year 35.70 1.30 2-Year 36.30 0.70 30-Year 36.66 0.34 25-Year 36.87 0.13 50-Year 37.02 -0.02 100-Year 37.06 -0.06 Pre -Main Pool Return Period Max. WSE hl Freeboard' Ikl 1-Year 35.70 1.30 2-Year 36.30 0.70 10-Year 36.64 0.36 25-Year 36.80 0.20 50-Year 36.92 0.08 300-Year 36.97 0.03 PROPOSED CONDITIONS Ditch N4 Return Period Max WSE Ikl 1-Year 36.09 2-Year 36.53 10-Year 36.86 25-Year 36.98 50-Year 37.00 300-Year 37.02 Ditch N5 Return Period Max WSE Ikl 1-Year 36.09 2-Year 36.51 10-Year 36.65 25-Year 36.71 50-Year 36.72 100-Year 36.74 Post-Forebay Return Period Max. WSE IN Freeboard [h] 1-Year 36.09 0.91 2-Year 36.53 0.47 10-Year 36.92 0.08 25-Year 37.04 -0.04 50-Year 37.07 -0.07 100-Year 37.11 -0.11 Post -Main Pool Return Period Max. WSE fhl Freeboard fkl I 1-Year 36.09 0.91 _ 2-Year 36.53 0.47 10-Year 36.88 0.12 25-Year 37.00 0.00 SO -Year 37.02 -0.02 300-Year 37.04 -0.04 UNCW - HURST HAMILTON PARKING LOTS SUMMARY OF RESULTS UNW-17060 SCM - Existing STORMWATER CONTROL MEASURE SUMMARY Design Drainage Area = 24.77 ac Design Impervious Area = 9.35 ac % Impervious = 37.7% Top of Dam = 37.00 ft NWSE= 33.30 ft Surface Area at NWSE = 53,925 sf WC. Orifice Diameter = 4.00 in WQ Orifice Elevation = 33.30 ft Number of Orifices = 2 Area Orifice #1 Area = 1.29 sf Area Orifice #1 Top Elevation = 34.39 ft Area Orifice #1 Invert Elevation = 33.96 ft Number of Orifices = 1 Area Orifice #2 Area = 3.69 sf Area Orifice #2 Top Elevation = 34.37 ft Area Orifice #2 Invert Elevation = 33.96 ft Riser Size = 6' x 10' Riser Crest = 35.56 ft Barrel Diameter= 24 in # of Barrels = 3 Upstream Invert= 33.75 ft Downstream Invert= 33.25 ft Length = 42 ft Slope = 0.0119 ft/ft R. STUBBS, El 2/9/2018 UNCW - HURST HAMILTON PARKING LOTS SUMMARY OF RESULTS UNW-17060 SCM - Modified STORMWATER CONTROL MEASURE SUMMARY Design Drainage Area = 27.98 ac Design Impervious Area = 13.96 ac `Y Impervious = 49.9% Top of Dam = 37.00 ft NWSE= 33.30 ft WQ Storm Depth = 0.96 ft WQ Volume= 61,573 cf WQ Volume Elevation = 34.26 ft Surface Area at NWSE = 31,275 sf WQ Orifice Diameter = 4.00 in WQ Orifice Elevation = 33.30 ft Number of Orifices = 2 Area Orifice #1 Area = 1.50 sf Area Orifice #1 Top Elevation = 34.80 ft Area Orifice #1 Invert Elevation = 34.30 ft Number of Orifices = 1 Area Orifice N2 Area = 4.50 sf Area Orifice fit Top Elevation = 34.80 ft Area Orifice k2 Invert Elevation = 34.30 ft Riser Size = 6' x 10' Riser Crest = 35.56 ft Barrel Diameter = 24 in # of Barrels = 3 Upstream Invert = 33.75 ft Downstream Invert = 33.25 ft Length = 42 ft Slope = 0.0119 ft/ft R. STUBBS, El 2/9/2018 O MISCELLANEOUS SITE INFORMATION UNCW - HURST HAMILTON PARKING LOTS UNW-17060 UNCW PROPERTY h. UNC WILMINGTO SITE AERIAL MAP 0 100 200 400 mmmmmmzz:� Feet PROJECT#: UNW-17060 I inch 200 fim WILMINGTON, NORTH CAROLINJ q - 4 • _ • �.tyt `��,�/ •�. 1 • u c .y �''�� • 1�' `A. 1 • r i J 10 • n i :, • �� UNCW PROPERTY -, 9. � I .. • � '' , . .'� cake r 1 � / PROJECT BOUNDARY .� • r °F ^ AT 7 gyp' � y � _. - � � `,I _ • n ap �040,1 .. ' ^ , • jr '� n sa t-y;• r—. \� /'�'/ Y , J 'r- Copyright © 01 National Ge graphic ociefy, i cu ed A UNC WILMINGTON 11, USGS TOPO MAP o 1,000 2,000 4,000 PROJECT #: UNW-17060 Feet inch 2,000 feet WILMINGTON, NORTH CAROLINA NC DENR- DIVISON OF WATER RESOURCES .0311 CAPE FEAR RIVER BASIN 2B.0300 Name of Stream Description Class Class Date Index No. Creek From source to Northeast Cape Fear C;Sw 09/01/74 18-74-60 River Northeast Cape Fear River From mouth of Ness Creek to Cape SC;Sw 04/01/59 18-74-(61) Fear River Ness Creek From source to Northeast Cape Fear C;Sw 09/01/74 18-74-62 River Smith Creek From source to Northeast Cape Fear C;Sw 09/01/74 18-74-63 River Spring Branch From source to Smith Creek C;Sw 09/O1174 18-74-63-1 .,Burnt Mill Creek From source to Smith Creek C;Sw 03/01/77 18-74-63-2� Mineral Springs Branch From source to Burnt Mill Creek C;Sw 08/O1/85 18-74-63-2-1 Alligator Creek From source to Cape Fear River SC;Sw 04/O1/59 18-75 Greenfield Creek From Greenfield Lake to Cape Fear SC;Sw 04/01/59 18-76 River Greenfield Lake Entire Lake C;Sw 04/01/59 18-76-1 Silver Stream Branch From source to Greenfield Lake, C;Sw 04/01/59 18-76-1-1 Greenfield Creek Clay Bottom Branch From source to Greenfield Lake, C;Sw 04/01/59 18-76-1-2 Greenfield Creek Jumping Run Branch From source to Greenfield Lake, C;Sw 04/01/59 18-76-1-3 Greenfield Creek Squash Branch From source to Greenfield Lake, C;Sw 04/01/59 18-76-1-4 Greenfield Creek swick River From source to Cape Fear River SC 08/09/81 18-77 Sturgeon Creek From source to Burnswick River C;Sw 04/01/59 18-77-1 Mill Creek From source to Sturgeon Creek C;Sw 04/01/59 18-77-1-1 Rowell Branch From source to Mill Creek C;Sw 04/01/59 18-77-1-1-1 Banton Branch From source to Mill Creek C;Sw 04/01/59 18-77-1-1-2 Redmond Creek From source to Brunswick River SC;Sw 04/01/59 18-77-2 Jackeys Creek From source to Brunswick River C;Sw 04/01/59 18-77-3 Piney Branch From source to Jackeys Creek C;Sw 04/01/59 18-77-3-1 Mallory Creek From source to Cape Fear River C;Sw 04/01/59 18-78 Little Mallory Creek (Beaverdam From source to Mallory Creek C;Sw 04/01/59 18-78-1 Branch) Bamards Creek From source to Cape Fear River C;Sw 04/01/59 18-80 Town Creek (Rattlesnake From source to Cape Fear River C;Sw 09/01/74 18-81 Branch) Turkey Branch From source to Town Creek C;Sw 04/01/59 18-81-1 Lewis Swamp From source to Town Creek C;Sw 09/01/74 18-81-2 Tompkins Branch (Tomolin From source to Lewis Swamp C;Sw 09/01/74 18-81-2-1 Branch) Lewis Branch From source to Lewis Swamp C;Sw 09/01/74 18-81-2-2 ' erdam Swamp From source to Town Creek C;Sw 09/01/74 18-81-3 r,__, Creek From source to Town Creek C;Sw 04/01/59 18-81-4 Russells Creek From source to Town Creek C;Sw 09/01/74 18-81-5 47 IV PO4f je t. to 00 Z 744. uj 0 z z M ou- Awl' A P AW IN El 0 VNIIMAVO Hi2JON `NOiONIW-1IM ON O0Z y"" 090LVMNn :# 103f oNd laa� 004 ON OOL 0 d`dW IIOS NOlJNIWIIM ONn y Fri I aowaa uo,4eAuasa2@ seoinosaa leinjeN vase .aomoS ANVaNnoa 103road _11 IML AIN3dOad MONn 12/22/2016 Precipitation Frequency Data Server NOAA Atlas 14, Volume 2, Version 3 Location name: Wilmington, North Carolina, USA* Latitude: 34.2227°, Longitude:-77.8652' E Elevation: 35.37 fP" } 'source. ESRI Maps „mow source: USGS POINT PRECIPITATION FREQUENCY ESTIMATES G.M. Bonnin, D. Martin, B. Lin, T Parzybok, M.Yekta, and O. Riley NOAA, National Nkather Sew e, Silver Spring, Maryland PF tabular I PF graphical I Maps & aerials PF tabular PDS-based point precipitation frequency estimates with 90% confidence intervals (in inches)1 Average recurrence interval (years) Duration 1 2 5 F-������� 10 25 50 100 200 500 1000 00-0. 0.728 02-0, 0.995 1.16 1.-1 1.-1 5-r11in (0489-0.565) 89-0. (0.560-0.670) (0678-0783) (0752-0872) 46-0. (0.846-0.982) (0.914-1.07) 84-1 (0984-1.16) (1.05-124) (113-136) (120-145) 0.637 0.995 1.17 1.30 1.46 1.58 1.71 1.83 1.99 2.12 10-min (0782-0902) (0928-1.07) (1.09-1.25) (120-139) (135-156) (146-1.70) (1.56-1.84) ( 1.67-1.97 ) ( 1.79-215 ) ( 189-229 ) 1.05 1.25 1.46 1.64 1.85 2.01 2 16-IF 2.31 2.51 2.66 15-min (0.977-113) (117-135) (137-159) (152-176) (1.71-1.98) (184-215) (198-232) (2.10-2.49) ( 2.26-2.71) ( 237-2.87) 1.43 1.73 2.10 2.38 2.74 3.02 3.31 3.60 4.- 4.31 30-min (134-154) (1.61-1.86) (1.95-225) (221-256) (253-294) (2.78-3.24) ( 3.03-3.55) ( 3.27-387) ( 359-431) ( 384-466 ) 1.79 2.17 2.69 3.10 3.65 4.09 4.56 5.05 5.73 6.29 60-min (167-193) (202-233) (250-289) (287-333) (3.37-3.91) (3.76-4.39) (417-489) (459-543) (516-618) (561-6.79) 2 - 2.57 3.28 3.87 4.72 5.45 6.24 7.11 8.39 9.50 2-hr (1.95-231) (237-281) (3.02-358) (3.55-4.22) (431-514) (4.95-593) (564-679 j ( e38-7.72 ) ( 745-9.13 j ( 836-104 ) 2.25 2.74 3.51 4.17 5.16 6.02 6.98 8.05 9.67 11.1 3-hr (2.08-247) (2.53-300) (3.23-3.84) (3.82-456) (470-562) (545-656) (627-759) ( 7.17-8.73) ( 850-10.5) ( 963-121) 2.60 3.41 4.37 5.20 6.46 7.55 8.79 10.2 12.3 14.1 6•hr (2.59-308) (3.15-375) (4.02-479) 1 (4.77-5.70) 1 (588-7.04) (6.83-8.24) (789-957) (903-111) (10.8-13.4) (12.3-154) 3.28 3.99 5.15 6.17 7.70 9.07 10.6 12.4 15.1 17.5 12-hr (3.00-363) (365-441) (4.70-5.68) (5.60-6.79) (694-846) (812-994) (943-116) (10.9-13.5 ) ( 13.1-16.5 ) ( 149-191 ) 3.88 4.70 6.09 7.31 9.18 10.9 12.8 14.9 -IF213 24•hr (353-4.32) (4.29-525) (5.54-6.78) (663-8.12) (825-102) (966-12.0) (11.2-14.2) (12.9-16.6) (155-205) (178-239) 4.60 F 5.56 7.13 8.51 1067F 124-IF 14.5 16.9 20.5 23.7 24ay (421-5.09) (5.09-6.15) (6.51-7.90) (773-9.42) (954-117) (111-138) (12.8-16.2) ( 14.7-18.9) ( 174-230) ( 198-268) 4.90 5.91 7.53 8.94 11.0 12.9 15.0 17.3 20.8 23.9 3-day (449-541) (542-653) (689-8.33) (8.14-9.88) (997-122) (115-143) (132-i66) (15.1-19.3) (17.8-234) (201-271) 5.20 6.26 7.94 9.37 11.5 13.3 15.4 17.7 21.1 24.2 4i1ay F47-day-17 (477-573) (575-6.91) (726-8.76) (8.54-103) (10.4-12.7) (120-148) (137-171) ( 15.5-19.7) ( 182-237) ( 205-273) 5.96 7.19 9.05 10.6 12.9 14.8 16.9 19.1 22.5 25.3 7- ay (552-651) (665-7.84) (835-986) (974-115) (118-140) (13.4-16.1) ( 152-184) ( 170-210) ( 197-249) ( 2t8-282) 6.75 8.07 10.0 11.6 14.0 16.0 16.1 20.4 23.6 26.6 10-day (625-7.31) (749-8.77) (925-109) (107-126) (12.8-15.2) (14.5-174 ) ( 163-197 ) ( 182-223 ) ( 209-262 ) ( 231-29.5 ) 9.01 10.7 13.1 15.0 17.8 20.0 22.5 25.0 28.7 31.7 20-day (841969) 1 (100-116) 1 (122-141) 1 (14.0-16.1) 1 (16.5-19.1) (184-216) (205-24:3) (227-272) (25.6-31.4) (27.9-35.0) 11.1 13.1 15.8 17.9 20.9 23.3 25.7 26.3 31.8 34.6 30-day (104118) 1 (124-140) 1 (148-168) 1 (16.8-19.1) 1 (195-223) (216-249) (237-27.6) (259-30.4) (28.8-34.4) (31.0-37.7) 13.8 16.3 19.4 F 21.8 F 25.2 279-17 30.7 33.5 37.4 40.4 45-day (130147) (15.4-174) (18.2-20.6) (20.5-23.2) (236-268) (260-297) (28.4-32.7) ( 30.8-35.9) ( 34.0-40.3) ( 365-439) 16.6 19.5 22.8 25.5 29.0 31.8 34.5 37.3 41.0 1 43.6 60-day (15.7-176) (18.5-20.7) (21.6-242) (241-270) (273-308) (298-338) (32136.8) (34.6-39.9) (3T7-440) (400-473) 1 Precipitation frequency (PF) estimates in this table are based on frequency analysis of partial duration series (PDS). Numbers in parenthesis are PF estimates at lower and upper bounds of the 90 % confidence interval. The probability that precipitation frequency estimates (far a given duration and average recurrence interval) will be greater than the upper bound (or less than the lower bound) is 5 %. Estimates at upper bounds are not checked against probable maximum precipitation (PMP) estimates and may be higher than currently valid PMP values. Please refer to NOAA Atlas 14 document for more information. http://hdsc.ms.noaa.gov/hdsc/pfds/pfds_lri ntpage.htm l?tat=34.2227&Ion=-77.8652&data=depth&units=engl ish&series=pds 114 9 MCADAMS Storm Data Detailed Report: U N W 17060 Element Details ID 40 Notes Label UNW17060 1yr24hr Label lyr 24hr Increment 5.00 min Return Event 1 years End Time 1,440.00 min Start Time 0.00 min Storm Event Depth Type Cumulative _ iyr 24hr Time Depth Depth Depth Depth Depth '(min) (in) (in) (in) (in) (in) 0.00 0.000 0.004 0.008 0.013 0.017 25.00 0.021 0.025 0.029 0.033 0.037 50.00 0.042 0.046 0.050 0.054 0.058 75.00 0.063 0.067 0.071 0.075 0.079 100.00 0,083 0.087 0.092 0.096 0.100 125.00 0.104 0.108 0.113 0.117 0.121 150.00 0.125 0.129 0.133 0.138 0.142 175.00 0.146 0.150 0.154 0.158 0.163 200.00 0.167 0,171 0.175 0.179 0.183 225.00 0.188 0.192 0.196 0.200 0.204 250.00 0.208 0.212 0.217 0.221 0.225 275.00 0.229 0.233 0.238 0.242 0.246 300.00 0.250 0.254 0.258 0.262 0.267 325.00 0.271 0.275 0.279 0.283 0.288 350.00 0.292 0.296 0.300 0.307 0.313 375.00 0.320 0.327 0.333 0.340 0.347 400.00 0.353 0.360 0.367 0.373 0.380 425.00 0.387 0.393 0.400 0.407 0.413 450.00 0.420 0.427 0.433 0.440 0.447 475.00 0.453 0.460 0.467 0.473 0.480 500.00 0.487 0.493 0.500 0.507 0.513 525.00 0.520 0.527 0.533 0.540 0.555 550.00 0.571 0.586 0.601 0.616 0.632 575.00 0.647 0.662 0.678 0.693 0.708 600.00 0.723 0.739 0.754 0.769 0.784 625.00 0.800 0.815 0.827 0.838 0.850 650.00 0.862 0.873 0.885 0.912 0.938 675.00 0.965 0.992 1.018 1.045 1.127 700.00 1.209 1.292 1.374 1.639 2.159 725.00 2.424 2.506 2.588 2.671 2.753 750.00 2.835 2.862 2.888 2.915 2.942 775.00 2.968 2.995 3.007 3.018 3.030 800.00 3.042 3.053 3.065 3.080 3.096 825.00 3.111 3.126 3.141 3.157 3.172 850.00 3.187 3.203 3.218 3.233 3.248 875.00 3.264 3.279 3,294 3.309 3.325 900.00 3.340 3.347 3.353 3.360 3,367 925.00 3.373 3.380 3.387 3.393 3.400 950.00 3.407 3.413 3.420 3.427 3.433 975.00 3.440 3.447 3.453 3.460 3.467 1,000.00 3.473 3.480 3.487 3.493 3.500 1,025.00 3.507 3.513 3.520 3.527 3.533 Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppc 2/9/2018 9 MCADAMS Storm Data Detailed Report: U N W 17060 lyr 24hr Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 1,050.00 3.540 3.547 .3.553 3.560 3.567 1,075.00 3.573 3.580 3.584 3.588 3.593 1,100.00 3.597 3.601 3.605 3.609 3.613 1,125.00 3.618 3.622 3.626 3.630 3.634 1,150.00 3.638 3.643 3.647 3.651 - 3.655 1,175.00 3.659 3.663 3.668 3.672 3.676 1,200.00 3.680 3.684 3.688 3.693 3.697 1,225.00 3.701 3.705 3.709 3.713 3.718 1,250.00 3.722 3.726 3.730 3.734 3.738 1,275.00 3.743 3.747 3.751 3.755 3.759 1,300.00 3.763 3.768 3.772 3.776 3.780 1,325.00 3.784 3.788 3.793 3.797 3.801 1,350.00 3.805 3.809 3.813 3.818 3.822 1,375.00 3.826 3.830 3.834 3.838 3.843 1,400.00 3.847 3.851 3.855 3.859 3.863 1,425.00 3.868 3.872 3.876 3.880 (N/A) 2yr 24hr Label 2yr 24hr Increment 5.00 min Return Event 2 years End Time 1,440.00 min Start Time 0.00 min Storm Event Depth Type Cumulative 2yr 24hr Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 0.00 0.000 0.005 0.010 0.015 0.020 25.00 0.025 0.030 0.035 0.039 0.044 50.00 0.049 0.054 0.059 0.064 0.069 75.00 0.074 0.079 0.084 0.089 0.094 100.00 0.099 0.104 0.108 0.113 0.118 125.00 0.123 0.128 0.133 0.138 0.143 150.00 0.148 0.153 0.156 0.163 0.168 175.00 0.173 0.178 O. 182 0.187 0.192 200.00 0.197 0.202 0.207 0.212 0.217 225.00 0.222 0.227 0.232 0.237 0.242 250.00 0.247 0.251 0.256 0.261 0.266 275.00 0.271 0.276 0.281 0.286 0.291 300.00 0,296 0.301 0.306 0.311 0.316 325.00 0.320 0.325 0.330 0.335 0.340 350.00 0.345 0.350 0.355 0.363 0.371 375.00 0.379 0.387 0.395 0.403 0.411 400.00 0.419 0.428 0.436 0.444 0.452 425.00 0.460 0.468 0.476 0.484 0.492 450.00 0.500 0.508 0.516 0.524 0.532 475.00 0.540 0.548 0.556 0.564 0.573 500.00 0.581 0.589 0.597 0.605 0.613 525.00 0.621 0.629 0.637 0.645 0.664 550.00 0.682 0.701 0.719 0.738 0.757 575.00 0.775 0.794 0.813 0.831 0.850 600.00 0.868 0.887 0.906 0.924 0.943 Hamilton -Hurst Parking Lot R. STUBBS, El UN W 17060. ppc 2/9/2018 9 MCADAMS Storm Data Detailed Report: UNW17060 2yr 24hr Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 625.00 0.961 0.980 0.994 1.008 1.023 650.00 1.037 1.051 1.065 1.098 1.132 675.00 1.165 1.198 1.232 1.265 1.367 700.00 1.469 1.572 1.674 1.989 2.609 725.00 2.924 3.026 3.128 3.231 3.333 750.00 3.435 3.468 3.502 3.535 3.568 775.00 3.602 3.635 3.649 3,663 3.678 800.00 3.692 3.706 3.720 3,739 3.757 825.00 3.776 3.794 3.813 3.832 3.850 850.00 3.869 3.888 3.906 3.925 3.943 875.00 3.962 3.981 3.999 4.018 4.036 900.00 4.055 4.063 4.071 4.079 4.087 925.00 4.095 4.103 4.111 4.119 4.128 950.00 4.136 4.144 4.152 4.160 4.168 975.00 4.176 4.184 4.192 4.200 4.208 1,000.00 4.216 4.224 4.232 4.240 4.248 1,025.00 4.256 4.264 4.273 4.281 4.289 1,050.00 4.297 4.305 4.313 4.321 4.329 1,075.00 4.337 4.345 4.350 4.355 4.360 1,100.00 4.365 4.370 4.375 4.380 4.384 1,125.00 4.389 4.394 4.399 4.404 4.409 1,150.00 4.414 4.419 4.424 4.429 4.434 1,175.00 4.439 4.444 4.449 4.453 4.458 1,200.00 4.463 4.468 4.473 4.478 4.483 1,225.00 4.488 4.493 4.498 4.503 4.508 1,250.00 4,513 4.518 4.523 4.527 4.532 11275.00 4.537 4.542 4.547 4.552 4.557 11300.00 4.562 4.567 4.572 4.577 4.582 11325.00 4.587 4.592 4.596 4.601 4.606 11350.00 4.611 4.616 4.621 4.626 4.631 11375.00 4.636 4.641 4.646 4.651 4.656 11400.00 4.661 4.665 4.670 4.675 4.680 1,425.00 4.685 4.690 4.695 4.700 (N/A) 10yr24hr Label 10yr 24hr Increment 5.00 min Return Event 10 years End Time 1,440.00 min Start Time 0.00 min Storm Event Depth Type Cumulative 10yr24hr Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 0.00 0.000 0.008 0.016 0.024 0.032 25.00 0.040 0.048 0.055 0.063 0.071 50.00 0.079 0.087 0.095 0.103 0.111 75.00 0.119 0.127 0.135 0.143 0.150 100.00 0.158 0.166 0.174 0.182 0.190 125.00 0.198 0.206 0.214 0.222 0.230 150.00 0.238 0.245 0.253 0.261 0.269 175.00 0.277 0.285 0.293 0.301 0.309 Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppc 2/9/2018 9 MCADAMS Storm Data Detailed Report: U N W 17060 10yr24hr Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 200.00 0.317 0.325 0.333 0.340 0.348 225.00 0.356 0.364 0.372 0.380 0.388 250.00 0.396 0.404 0.412 0.420 0.428 275.00 0.435 0.443 0.451 0.459 0.467 300.00 0.475 0.483 0.491 0.499 0.507 325.00 0.515 0.523 0.530 0.538 0.546 350.00 0.554 0.562 0.570 0.583 0.597 375.00 0.610 0.624 0.637 0.651 0.664 400.00 0.678 0.691 0.705 0.718 0.732 425.00 0.745 0.759 0.772 0.786 0.799 450.00 0.813 0.826 0.839 0.853 0.866 475.00 0.880 0.893 0.907 0.920 0.934 500.00 0.947 0.961 0.974 0.988 1.001 525.00 1.015 1.028 1.042 1.055 1.084 550.00 1.112 1.141 1.169 1.196 1.227 575.00 1.255 1.284 1.313 1.341 1.370 600.00 1.398 1.427 1.456 1.484 1.513 625.00 1.541 1.570 1.595 1.620 1.645 650.00 1.670 1.695 1.720 1.784 1.848 675.00 1.913 1.977 2.041 2.105 2.267 700.00 2.429 2.592 2.754 3.169 3.979 725.00 4.394 4.556 4.718 4.881 5.043 750.00 5.205 5.269 5.333 5.398 5.462 775.00 5.526 5.590 5.615 5.640 5.665 800.00 5.690 5.715 5.740 5.769 5.797 825.00 5.826 5.854 5.883 5.912 5.940 850.00 5.969 5.998 6.026 6.055 6.083 875.00 6.112 6.141 6.169 6.198 6.226 900.00 6.255 6.268 6.282 6.295 6.309 925.00 6.322 6.336 6.349 6.363 6.376 950.00 6.390 6.403 6.417 6.430 6.444 975.00 6.457 6.471 6.484 6.498 6.511 1,000.00 6.524 6.538 6.551 6.565 6.578 1,025.00 6.592 6.605 6.619 6.632 6.646 1,050.00 6.659 6.673 6.686 6.700 6.713 1,075.00 6.727 6.740 6.748 6.756 6.764 1,100.00 6.772 6.780 6.788 6.795 6,803 1,125.00 6.811 6.819 6,827 6.835 6.843 1,150.00 6.851 6.859 6.867 6.875 6.883 1,175.00 6.890 6.898 6,906 6.914 6.922 1,200.00 6.930 6.938 6.946 6.954 6.962 1,225.00 6.970 6.978 6.985 6.993 7.001 1,250.00 7.009 7.017 7.025 7.033 7.041 1,275.00 7.049 7.057 7.065 7.073 7.080 1,300.00 7.088 7.096 7.104 7.112 7.120 1,325.00 7.128 7.136 7.144 7.152 7.160 1,350.00 7.168 7.175 7.183 7.191 7.199 1,375.00 7.207 7.215 7.223 7.231 7.239 1,400.00 7.247 7.255 7.263 7.270 7.278 1,425.00 7,286 7.294 7.302 7.310 (N/A) Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppe _ 2/9/2016 9 MCADAMS Storm Data Detailed Report: U N W 17060 25yr 24hr Label 25yr 24hr Increment 5.00 min Return Event 25 years End Time 1,440.00 min Start Time 0.00 min Storm Event Depth Type Cumulative 25yr 24hr Time Depth Depth Depth Depth Depth (min) (in) (in) (in) - (in) (in) 0.00 0.000 0.010 0.021 0.031 0.041 25.00 0.051 0.062 0.072 0.082 0.092 50.00 0.103 0.113 0.123 0.134 0.144 75.00 0.154 0.164 0.175 0.185 0.195 100.00 0.206 0.216 0.226 0.236 0.247 125.00 0.257 0.267 0.278 0.288 0.298 150.00 0.308 0.319 0.329 0.339 0.349 175.00 0.360 0.370 0.380 0.391 0.401 200.00 0.411 0.421 0.432 0.442 0.452 225.00 0.462 0.473 0.483 0.493 0.504 250.00 0.514 0.524 0.534 0.545 0.555 275.00 0.565 0.576 0.586 0.596 0.606 300.00 0.617 0.627 0.637 0.647 0.658 325.00 0.668 0.678 0.689 0.699 0.709 350.00 0.719 0.730 0.740 0.757 0.774 375.00 0.792 0.809 0.826 0.843 0.861 400.00 0.878 0.895 0.912 0.929 0.947 425.00 0.964 0.981 0.998 1.016 1.033 450.00 1.050 1.067 1.084 1.102 1.119 475.00 1.136 1.153 1.171 1.188 1.205 500.00 1.222 1,239 1.257 1.274 1.291 525.00 1.308 1.326 1.343 1.360 1.396 550.00 1.432 1.468 1.504 1.541 1.577 575.00 1.613 1.649 1,685 1.721 1.757 600.00 1.793 1.829 1,866 1.902 1.938 625.00 1.974 2.010 2.047 2.083 2.120 650.00 2.157 2.193 2.230 2.319 2.408 675.00 2.498 2.587 2.676 2.765 2.965 700.00 3.165 3.365 3.565 4.030 4.950 725.00 5.415 5.615 5.815 6.015 6.215 750.00 6.415 6.504 6.593 6.683 6.772 775.00 6.861 6.950 6.987 7.023 7.060 800.00 7.097 7.133 7.170 7.206 7.242 825.00 7.278 7.314 7.351 7.387 7.423 850.00 7.459 7.495 7.531 7.567 7.603 875.00 7.639 7.676 7.712 7.748 7.784 900.00 7.820 7.837 7.854 7.872 7.889 925.00 7.906 7.923 7.941 7.958 7.975 950.00 7.992 8.009 8.027 8.044 8.061 975.00 8.076 8.096 8.113 8.130 8.147 1,000.00 8.164 8.182 8.199 8.216 8.233 1,025.00 8.251 8.266 8.285 8.302 8.319 1,050.00 8.337 8.354 8.371 8.388 8.406 1,075.00 8.423 8.440 8.450 8.461 8.471 1,100.00 8.481 8.491 8.502 8.512 8.522 1,125.00 8.533 8,543 8.553 8.563 8.574 Hamilton -Hurst Parking Lot R. Maas, El UNW17060.ppc 2/9/2018 'J MCADAMS Storm Data Detailed Report: U N W 17060 25yr24hr Time (min) 1,150.00 1,175.00 1,200.00 1,225.00 1,250.00 1,275.00 1,300.00 1,325.00 1,350.00 1,375.00 1,400.00 1,425.00 50yr24hr Depth (in) 8.584 8.635 8.687 8.738 8.789 8.841 8.892 8.944 8.995 9.046 9.098 9.149 Depth (in) 8.594 8.646 8.697 8.748 8.800 8.851 8.903 8.954 9.005 9.057 9.108 9.159 Depth (in) 8.604 8.656 8.707 8.759 8.810 8.861 6.913 8.964 9.016 9.067 9.118 9.170 Depth (in) 8.615 8.666 8.718 8.769 8.820 8.872 8.923 6.974 9.026 9.077 9.129 9.180 Depth (in) 8.625 8.676 8.728 8.779 8.831 8.882 8.933 8.985 9.036 9.088 9.139 (N/A) Label 50yr 24hr Increment 5.00 min Return Event 50 years End Time 1,440.00 min Start Time 0.00 min Storm Event Depth Type Cumulative 50yr24hr Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 0.00 0.000 0.012 0.025 0.037 0.050 25.00 0.062 0.075 0.087 0.099 0.112 50.00 0.124 0.137 0.149 0.162 0.174 75.00 0.186 0.199 0.211 0.224 0.236 100.00 0.249 0.261 0.273 0.286 0.298 125.00 0.311 0.323 0.336 0.348 0.360 150.00 0.373 0.385 0.398 0.410 0.423 175.00 0.435 0.448 0.460 0.472 0.485 200.00 0.497 0.510 0.522 0.535 0.547 225.00 0.559 0.572 0.584 0.597 0.609 250.00 0.622 0.634 0.646 0.659 0.671 275.00 0.684 0.696 0.709 0.721 0.733 300.00 0.746 0.758 0.771 0.783 0.796 325.00 0.808 0.820 0.833 0.845 0.858 350.00 0.870 0.883 0.895 0.916 0.937 375.00 0.958 0.979 1.001 1.022 1.043 400.00 1.064 1.085 1.106 1.127 1.148 425.00 1.169 1.191 1.212 1.233 1.254 450.00 1.275 1.296 1.317 1.338 1.359 475.00 1.381 1.402 1.423 1.444 1.465 500.00 1,486 1.507 1.528 1.549 1.571 525.00 1.592 1.613 1.634 1.655 1.698 550.00 1.740 1.783 1.825 1.868 1.910 575.00 1.953 1.995 2.038 2.080 2.123 600.00 2.165 2.208 2.250 2.293 2.335 625.00 2.378 2.420 2.468 2.515 2.563 650.00 2.610 2.658 2.705 2.818 2.932 675.00 3.045 3.158 3.272 3.385 3.616 700.00 3.847 4.078 4.309 4.819 5.809 Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppc 2/9/2018 9 MCADAMS Storm Data Detailed Report: U N W 17060 50yr24hr Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 725.00 6.319 6.551 6.782 7.013 7.244 750.00 7.475 7.588 7.702 7.815 7.928 775.00 8.042 8.155 8.203 8.250 8.298 800.00 8.345 8.393 8.440 8.483 8.525 825.00 8.568 8.610 8.653 8.695 8.738 850.00 8.780 8.823 8.865 8.908 8.950 875.00 8.993 9.035 9.078 9.120 9.163 900.00 9.205 9.226 9.247 9.268 9.289 925.00 9.311 9.332 9.353 9.374 9.395 950.00 9.416 9.437 9.458 9.479 9.501 975.00 9.522 9.543 9.564 9.585 9.606 1,000.00 9.627 9.648 9.669 9.691 9.712 1,025.00 9.733 9.754 9.775 9.796 9.817 1,050.00 9.838 9.859 9.881 9.902 9.923 1,075.00 9.944 9.965 9.977 9.990 10.002 1,100.00 10.015 10.027 10.040 10.052 10.064 1,125.00 10.077 10.089 10.102 10.114 10.127 1,150.00 10.139 10.151 10.164 10.176 10.189 1,175.00 10.201 10.214 10.226 10.238 10.251 1,200.00 10.263 10.276 10.288 10.301 10.313 1,225.00 10.325 10.338 10.350 10.363 10.375 1,250.00 10.388 10.400 10.413 10.425 10.437 1,275.00 10.450 10.462 10.475 10.487 10.500 1,300.00 10.512 10.524 10.537 10.549 10.562 1,325.00 10.574 10.587 10.599 10.611 10.624 1,350.00 10.636 10.649 10.661 10.674 10.686 1,375.00 10.698 10.711 10.723 10.736 10.748 1,400.00 10.761 10.773 10.785 10.798 10.810 1,425.00 10,823 10.835 10.848 10.860 (N/A) 100yr24hr Label 100yr 24hr Increment 5.00 min Return Event 100 years End Time 1,440.00 min Start Time 0.00 min Storm Event Depth Type Cumulative 100yr24hr Time Depth Depth Depth Depth Depth (min) (in) (in) (in) - (in) (in) 0.00 0.000 0.015 0.030 0.045 0.060 25.00 0.075 0.090 0.105 0.119 0.134 50.00 0.149 0.164 0.179 0.194 0.209 75.00 0.224 0.239 0.254 0.269 0.284 100.00 0.299 0.314 0.328 0.343 0.358 125.00 0.373 0.388 0.403 0.418 0.433 150.00 0.448 0.463 0.478 0.493 0.508 175.00 0.523 0.538 0.552 0.567 0.582 200.00 0.597 0.612 0.627 0.642 0.657 225.00 0.672 0.687 0.702 0.717 0.732 250.00 0.747 0.761 0.776 0.791 0.806 275.00 0.821 0.836 0.851 0.866 0.881 Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppc . 2/9/2018 'J MCADAMS Storm Data Detailed Repot, ® U N W 17060 100yr24hr Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 300.00 0.896 0.911 0.926 0.941 0.956 325.00 0.970 0.985 1.000 1.015 1.030 350.00 1.045 1.060 1.075 1.100 1.126 375.00 1.151 1.176 1.201 1.227 1.252 400.00 1:277 1.303 1.328 1.353 1.378 425.00 1.404 1.429 1.454 1.479 1.505 450.00 1.530 1.555 1.581 1.606 1.631 475.00 1.656 1.682 1.707 1.732 1.758 500.00 1.783 1.808 1.833 1.859 1.884 525.00 1.909 1.934 1.960 1.985 2.035 550.00 2.086 2.136 2.186 2.236 2.287 575.00 2.337 2.387 2.438 2.488 2.538 600.00 2.588 2.639 2.689 2.739 2.789 625.00 2.840 2.890 2.952 3.013 3.075 650.00 3.137 3.198 3.260 3.400 3.540 675.00 3.680 3.820 3.960 4.100 4.367 700.00 4.633 4.900 5.167 5.707 6.787 725.00 7.327 7.593 7.860 8.127 8.393 750.00 8.660 8.800 8.940 9.080 9.220 775.00 9.360 9.500 9.562 9.623 9.685 800.00 9.747 9.808 9.870 9.920 9.971 825.00 10.021 10.071 10.121 10.172 10.222 850.00 10.272 10.323 10.373 10.423 10.473 875.00 10.524 10.574 10.624 10.674 10.725 900.00 10.775 10.800 10.826 10.851 10.876 925.00 10.901 10.927 10.952 10.977 11.003 950.00 11.028 11.053 11.078 11.104 11.129 975.00 11.154 11.179 11.205 11.230 11.255 1,000.00 11.281 11.306 11.331 11.356 11.382 1,025.00 11.407 11.432 11.458 11.483 11.508 1,050.00 11.533 11.559 11.584 11.609 - 11.634 1,075.00 11.660 11.685 11.700 11.715 11.730 1,100.00 11.745 11.760 11.775 11.790 11.804 1,125.00 11.819 11.834 11.849 11.864 11.879 1,150.00 11.894 11,909 11.924 11.939 11.954 1,175.00 11.969 11.984 11.999 12.013 12.028 1,200.00 12.043 12.058 12.073 12.088 12.103 1,225.00 12.118 12.133 12.148 12.163 12.178 1,250.00 12.193 12.208 12.223 12.237 12.252 1,275.00 12.267 12.282 12.297 12.312 12.327 1,300.00 12.342 12.357 12.372 12.387 12.402 1,325.00 12.417 12.432 12.446 12.461 12.476 1,350.00 12.491 12.506 12.521 12.536 12.551 1,375.00 12.566 12.581 12.596 12.611 12.626 1,400.00 12.641 12.655 12.670 12.685 12.700 1,425.00 12.715 12.730 12.745 12.760 (N/A) Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppc 2/9/2018 MCADAMS Storm Data Detailed Report: UNW17060 15.000 13.750 12.500 11.250 10.000 8.750 c t 7.500 n v 6.250 5.000 3.750 2,500 1.250 0.000 -6�--- ' 0.00 144.00 288.00 432.00 576.00 720.00 864.00 1,008.00 1,152.00 1,296.00 1,440.0( Time (min) 100yr 24hr - 50yr 24hr - 25yr 24hr - 10yr 24hr - 2yr 24hr - lyr 24hr Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppt 2/9/2018 PRE -DEVELOPMENT HYDROLOGIC CALCULATIONS UNCW - HURST HAMILTON PARKING LOTS U N W-17060 UNCW HURST HAMILTON PARKING LOT PRE -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW-17060 Summary of Results 2/9/2018 (HYDROLOGY INPUT SUMMARY Onsite Area [acres] - Offsite Area [acres] Total Area Sub -basin ID Impervious Open Wooded Pond Total Impervious Open Wooded Pond Total [acres] SCS CN Tc [min] Main Pool 0.50 0.70 2.75 0.94 4.88 0.00 0.29 0.00 0.00 0.29 5.17 57 25.37 Forebay 8.73 9.54 0.00 0.45 18.72 0.02 0.48 0.00 0.00 0.50 19.22 74 23.41 Ditch6 5.05 11.39 14.71 0.00 31.15 0.00 0.11 0.78 0.00 0.89 32.04 58 32.66 Ditch7 0.09 0.47 1.50 0.00 2.06 0.11 0.37 0.00 1 0.00 0.48 2.54 46 25.43 Totals= 14.38 22.09 18.96 1.38 56.81 0.13 1.26 0.78 0.00 2.17 58.97 UNCW HURST HAMILTON PARKING LOT PRE -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW-17060 Sub t0 Moin Pool 2/9/2018 1. SCS CURVE NUMBERS Assume: HSG Impervious Open Wooded ! A 98 39 30 B 96 61 55 C 9B 74 70 D 98 80 77 H5G'A'= 62.9% HSG'B'= 37.1% HSG'C'= 0.0% HSG'D'= 0.0% Cover Condition SCS ON Comments _ Impervious 98 Open 47 Assume good condition Wooded 39 Assume good condition II. PRE -DEVELOPMENT Watershed Breakdown Contributing Area SCS ON Area Area acres Comments Onsite impervious 98 21,701 0.50 Onsite open 47 30,406 0.70 Assume good condition Onsite wooded 39 119,710 2.75 Assume good condition Onsite pond 100 40,773 0.94 Offsite im ewious 98 0 0.00 Offsite open 47 12,795 0.29 Assume good condition Offsite wooded 39 0 0.00 Assume good condition Offsite pond 100 0 0.00 Total area = Composite SCS CN = % Impervious = 5.17 acres 225,385 sq. ft. 57 9.6% UNCW HURST HAMILTON PARKING LOT PRE -DEVELOPMENT HYDROLOGY ® UNW-17060 Sub to Main Pool III. TIME OF CONCENTRATION INFORMATION Time of concentration is calculated using the SCS Segmental Approach lTR-551. Segment 1: Overland Flow Length = 100 ft Top Elev= 38.5 ft Bot Elev= 36.5 ft Height= 2 it Slope= 0.0200 ft/ft Manning's n= 0.40 wooded, dense underbrush P (2-year/24-hour) = 4.70 inches (Wilmington, INC) Segment Time= 17.72 minutes Segment 3: Pipe Flow Length = 18 ft Top Elev= 36 Bar Elev= 35.75 Height= 0.25 it Slope = 0.0139 ft/ft Manning's n= 0.013 concrete Flow Area = 0.79 sf (assume 12" RCP) Wetted Perimeter= 3.14 If (assume 12" RCP) Channel Velocity= 5.36 ft/sec Segment Time= 0.06 minutes R. STUBBS, El 2/9/2018 Segment 2: Concentrated Flow Length = 300 H Tap Elev= 36.50 ft Bot Elev= 36 ft Height= 1 it Slope= 0.0017 ft/ft Paved 7= No Velocity= 0.66 ft/sec Segment Time= 7.59 minutes Time of Concentration= 25.37 minutes SCS Lag Time= 15.22 minutes SCS Lag =0.6-Tc) Time Increment= 4.41 minutes (=0.29-SCS tag) UNCW HURST HAMILTON PARKING LOT PRE -DEVELOPMENT HYDROLOGY R. STUBBS, EI UNW-17060 Sub to Forebay 2/9/2018 I. SCS CURVE NUMBERS Assume: HSG Impervious Open Wooded A 98 39 30 B 98 61 55 C 98 74 70 D 98 80 77 HSG'A'= 43.1% H5G'B'= 56.9% HSG'C'= 0.0% H5G'D'= 0.0% Cover Condition SCS CN Comments Impervious 98 Open 52 Assume good condition Wooded 44 Assume good condition II. PRE -DEVELOPMENT Watershed Breakdown Contributing Area SCS CN Area [s_fl Area' acres Comments 1 Onsite impervious 98 380,433 8.73 Onsite open 52 415,487 9.54 Assume good condition Onsite wooded 44 0 0.00 Assume good condition Onsite pond 100 19,500 0.45 - Offsite impervious 98 816 0.02 Offsite open 52 21,105 0.48 Assume good condition Offsite wooded 44 0 0.00 Assume good condition Offsite pond 100 0 0.00 Total area = Composite SCS CN = % Impervious = 19.22 acres 837,341 sq. R. 74 45.5% UNCW HURST HAMILTON PARKING LOT PRE -DEVELOPMENT HYDROLOGY UNW-17060 Sub to Foreboy III. TIME OF CONCENTRATION INFORMATION Time of concentration is calculated using the SCS Segmental Approach (TR-55/. Segment 1: Overland Flow Segment 1: Concentrated Flow Length = 100 ft Length = 235 Top Elev= 41.0 ft Top Elev= 40.5 Bot Elev= 40.5 ft Bot Elev= 37.9 Height= 0.5 ft Height= 3 Slope= 0.0050 ft/ft Slope= 0.0111 Manning's n= 0.24 dense grass Paved ?= No P (2-year/24-hour)= 4.70 inches (Wilmington, NC) Velocity= 1.70 Segment Time= 20.50 minutes Segment Time= 2.31 Segment 3: Pipe Flow Length = 358 ft Top Elev= 37.9 Bot Elev= 34.0 Height= 3.9 ft Slope= 0.0109 ft/ft Manning's n= 0.013 concrete Flow Area = 1.77 sf (assume 18" RCP) Wetted Perimeter= 2.36 If (assume 18" RCP) Channel Velocity= 9.88 ft/sec Segment Time= 0.60 minutes rime of Concentration= 23.41 minutes SCS Lag rime = 14.05 minutes (SCS Lag = 0.6` Tc) rime Increment= 4.07 minutes (=0.29•SCS Lag) R. STUBBS, El 2/9/2018 ft ft ft ft ft/ft ft/sec minutes UNCW HURST HAMILTON PARKING LOT PRE -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW-17060 Sub to Ditch6 2/9/2018 I. SCS CURVE NUMBERS Assume: HSG Impervious Open Wooded A 98 39 30 B 98 61 55 C 98 74 70 D 98 80 77 H5G'A'= 29.8% HSG'B'= 70.2% HSG'C'= 0.0% HSG'D'= 0.0% Cover Condition SCS CN Comments Impervious 98 Open S4 Assume good condition Wooded 48 Assume good condition II. PRE -DEVELOPMENT Watershed Breakdown Contributing Area SCS ON Area [sfl Area acres Comments Onsite impervious 98 220,015 5.05 Onsite open 54 495,933 11.39 Assume good condition Onsite wooded 48 640,858 14.71 Assume good condition Onsite pond 100 0 0.00 Offsite impervious 98 39 0.00 Offsite open 54 4,867 0.11 Assume good condition Offsite wooded 48 33,968 0.78 Assume good condition Offsite pond 100 0 0.00 - Total area = Composite SCS ON = % Impervious = 32.04 acres 1,395,680 sq. ft. 58 15.8% UNCW HURST HAMILTON PARKING LOT PRE -DEVELOPMENT HYDROLOGY UNW-17060 Sub to Ditch6 Ht. TIME OF CONCENTRATION INFORMATION Time of concentration is calculated using the SCS Segmental Approach (TR-55). Segment 1: Overland Flow Segment 2: Concentrated Flow Length= 100 it Length= 762 Top Elev= 42.00 ft Top Elev= 40.00 Bat Elev= 40.00 ft Bat Elev= 36.28 Height = 2 ft Height = 4 Slope = 0.0200 ft/ft Slope = 0.0049 Manning's n= 0.40 wooded, dense underbrush Paved?= No P (2-year/24-hour) = 4.70 inches (Wilmington, NC) Velocity= 1.13 Segment Time 17.72 minutes Segment Time 11.27 Segment 3: pipe Flow Length = 677 ft Top Elev= 33.91 Bot Elev= 33.00 Height = 0.91 ft Slope = 0.0013 ft/ft Manning's n = 0.013 concrete Flow Area = 1.23 sf (assume 15" RCP) Wetted Perimeter= 1.96 If (assume 15" RCP) Channel Velocity= 3.07 ft/sec Segment Time = 3.67 minutes Time of Concentration= 32.66 minutes SCS Lag Time= 19.59 minutes (SCS Lag =0.6-Tc) Time Increment = 5.68 minutes (=0.29-SCS Lag) R. STUBBS, El 2/9/2018 ft ft ft ft ft/ft ft/sec minutes UNCW HURST HAMILTON PARKING LOT PRE -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW-17060 Sub to Ditch? 2/9/2018 1. SCS CURVE NUMBER$ Assume: HSG Impervious Open Wooded A 98 39 30 B 98 61 55 C 98 74 70 0 98 80 77 HSG'A'= 67.2% H5G'B'= 32.8% HSG'C'= 0.0% HSG'D'= 0.0% Cover Condition SCS CN Comments _ Impervious 98 - Open 46 Assume good condition Wooded 38 Assume good condition 11. PRE -DEVELOPMENT Watershed Breakdown Contributing Area SCS CN Area Area acres Comments ! Onsite impervious 98 4,044 0.09 Onsite open 46 20,610 0.47 Assume good condition Onsite wooded 38 65,131 1.50 Assume good condition Onsite pond 100 0 0.00 - OffsiteImpervious 98 4,661 0.11 Offsite open 46 16,067 0.37 Assume good condition Offsite wooded 38 0 0.00 Assume good condition Offsite pond 100 0 0.00 - Total area= 2.54 acres 110,513 sq. h. Composite SCs CN = 46 % Impervious = 7.9% UNCW HURST HAMILTON PARKING LOT PRE -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW-17060 Sub to Ditch7 2/9/2018 Ill. TIME OF CONCENTRATION INFORMATION Time oJconcentration is calculated using the SCS Segmental Approach (TR-55). Segment 1: Overland Flow Segment 2: Concentrated Flow Length= 100 it Length= 96 Top Elev= 37.25 ft Top Elev= 36.00 Bot Elev= 36.00 it Bot Elev= 35.00 Height= 1.25 ft Height= 1 Slope= 0.0125 11 Slope= 0.0104 Manning's o= 0.40 wooded, dense underbrush Paved?= No P (2-year/24-hour)= 4.70 inches (Wilmington, NC) Velocity 1.65 Segment Time= 21.38 minutes Segment Time 0.97 Segment 3: Channel Flow Segment 4: Channel Flow Length= 104 ft Length= 389 Top Elev= 35.00 Top Elev= 34.00 Bot Elev= 34.00 Bat Elev= 33.00 Height= 1 ft Height= 1 Slope= 0,0096 WIT Slope= 0.0026 Manning's n= 0.045 nautral channel Manning's n= 0.045 Flow Area= 6.00 sf(assume 2'w x Th channel( Flow Area= 50.00 Wetted Perimeter= 8.00 If (assume 2'w x Th channel( Wetted Perimeter 25.00 Channel Velocity= 2.68 ft/sec Channel Velocity= 2.66 Segment Time= 0.65 minutes Segment Time= 2.43 Time of Concentration= 25.43 minutes SCS Lag Time= 15.26 minutes (SCS Lag =0.6-Tc) Time Increment= 4.43 minutes(=0.29'SCS Lag) it It it it ft/ft ft/sec minutes it ft/ft nautral channel sf )assume 5'w x 10'h channe If (assume 5'w x 30'h channel ft/sec minutes 9 MCADAMS Scenario: Pre- Development Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppo 2/9/2018 2 MCADAMS FlexTable: Catchment Table (UNW17060.ppc) Current Time: 0.00 min Notes Label Area SCS CN Time of Concentration M) (min) Pre Sub to Ditch#6 1,395,680 58 32.66 Pre Sub to Ditch#7 110,513 46 25.43 Pre Sub to Forebay 837,341 74 23.41 Pre Sub to MainPool 225,385 57 25.37 Post Sub to Ditch#1 263,581 68 18.10 Post Sub to Ditch#2 1,016,238 58 32.56 Post Sub to Ditch#3 11,492 71 5.00 Post Sub to Ditch#4 27,400 52 5.00 Post Sub to Ditch#5 33,897 71 5.00 Post Sub to Forebay 837,646 74 23.41 Post Sub to Main Pool 381,257 82 25.37 Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppc 2/9/2018 9 MCADAMS Subsection: Master Network Summary Catchments Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (min) (ft3/s) (years) (ac-ft) Sub to Forebay Pre- lyr 24hr 1 2.399 733.50 25.42 Sub to Forebay Pre- 2yr 24hr 2 3.385 733.50 36.25 Sub to Forebay Pre- 10yr 24hr 10 6.868 733.50 64.99 Sub to Forebay Pre- 25yr 24hr 25 9.545 733.50 82.27 Sub to Forebay Pre- 50yr 24hr 50 12.020 733.50 95.73 Sub to Forebay Pre- 100yr 24hr 100 14.872 733.50 109.15 Sub to Ditch#6 Pre- lyr 24hr 1 1.607 749.00 9.79 Sub to Ditch#6 Pre- 2yr 24hr 2 2.655 744.50 18.90 Sub to Ditch#6 Pre- 10yr 24hr 10 6.925 740.25 51.51 Sub to Ditch#6 Pre- 25yr 24hr 25 10.551 740.25 74.87 Sub to Ditch#6 Pre- 50yr 24hr 50 14.063 740.25 94.69 Sub to Ditch#6 Pre- 100yr 24hr 100 18.239 740.25 115.61 Sub to MainPool Pre- lyr 24hr 1 0.242 740.75 1.58 Sub to MainPool Pre- 2yr 24hr 2 0.405 737.50 3.22 Sub to MainPool Pre- 10yr 24hr 10 1.078 734.25 9.05 Sub to MainPool Pre- 25yr 24hr 25 1.654 734.00 13.27 Sub to MainPool Pre- 50yr 24hr 50 2.214 734.00 16.82 Sub to MainPool Pre- 100yr 24hr 100 2.862 734.00 20.56 Sub to Ditch#7 Pre- Syr 24hr 1 0.037 759.50 0.11 Sub to Ditch#7 Pre- 2yr 24hr 2 0.082 756.25 0.38 Sub to Ditch#7 Pre- 10yr 24hr 10 0.308 739.00 2.12 .Sub to Ditch#7 Pre- 25yr 24hr 25 0.526 735.75 3.80 Sub to Ditch#7 Pre- 50yr 24hr 50 0.749 735.75 5.34 Sub to Ditch#7 Pre- 100yr 24hr 100 1.026 735.75 7.02 Node Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (min) (ft3/s) (years) (ac-ft) Overall POA Pre- lyr 24hr 1 0.000 0.00 0.00 Overall POA Pre- 2yr 24hr 2 0.000 0.00 0.00 Overall PICA Pre- 10yr 24hr 10 7.524 839.71 21.66 Overall POA Pre- 25yr 24hr 25 14.500 799.So 32.47 Overall POA Pre- 50yr 24hr 50 21.210 791.00 38.64 Overall POA Pre- 100yr 24hr 100 28.969 788.50 40.18 Pond Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (min) (ft3/s) (years) (ac-ft) Maximum Maximum Water Pond Storage Surface (ac-ft) Elevation (ft) Pre-Forebay Pre- Syr 24hr 1 2.399 733.50 25.42 (N/A) (N/A) (IN) Pre-Forebay Pre- lyr 24hr 1 1.026 748.75 15.52 35.70 1.901 (OUT) Pre-Forebay Pre- 2yr 24hr 2 3.385 733.50 36.25 (N/A) (N/A) (IN) Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppc 2/9/2018 9 MCADAMS Subsection: Master Network Summary Pond Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Maximum Maximum Event Volume (min) (ft3/s) Water Pond Storage (years) (ac-ft) Surface (ac-ft) Elevation (ft) Pre-Forebay Pre- 2yr 24hr 2 1.299 745.00 23.98 36.30 2.613 (OLro Pre-Forebay Pre- 10yr 24hr 10 6.868 733.50 64.99 (N/A) (N/A) (IN) Pre-Forebay Pre- 10yr 24hr 10 4.424 736.25 36.80 36.66 3.163 (Our) Pre-Forebay Pre- 25yr 24hr 25 9.545 733.50 82.27 (N/A) (N/A) (IN) Pre-Forebay Pre- 25yr 24hr 25 7.080 727.00 32.94 36.87 3.507 (OUn Pre-Forebay Pre- 50yr 24hr 50 12.020 733.50 95.73 (N/A) (N/A) (IN) Pre-Forebay Pre- 50yr 24hr 50 9.535 738.75 39.34 37.02 4.393 (Olf ) Pre-Forebay Pre- 100yr 100 14.872 733.50 109.15 (N/A) (N/A) (IN) 24hr Pre-Forebay Pre- 100yr 100 12.311 734.50 43.98 37.06 6.406 (our) 24hr Pre -Main Pool Pre- lyr 24hr 1 1.267 748.50 16.95 (N/A) (N/A) (IN) ire-MainPool Pre- lyr 24hr 1 0.000 0.00 0.00 35.70 4.292 (OUP Pre -Main Pool Pre- Syr 24hr 1 -1.052 759.50 -8.53 (N/A) (N/A) (Reverse) Pre -Main Pool Pre- 2yr 24hr 2 1.704 744.75 26.84 (N/A) (N/A) (IN) Pre-MainPool Pre- 2yr 24hr 2 0.000 0.00 0.00 36.30 5.281 (OUT) Pre-MainPool Pre- 2yr 24hr 2 -1.623 749.75 -12.85 (N/A) (N/A) (Reverse) Pre-MainPool Pre- 10yr 24hr 10 5.502 736.25 45.83 (N/A) (N/A) (IN) Pre-MainPool Pre- 10yr 24hr 10 3.130 872.00 10.13 36.64 6.014 (OUn Pre-MainPool Pre- 10yr 24hr 10 -1.410 742.50 -22.53 (N/A) (N/A) (Reverse) Pre-MainPool Pre- 25yr 24hr 25 8.734 734.25 45.78 (N/A) (N/A) (IN) Pre -Main Pool Pre- 25yr 24hr 25 5.816 768.00 19.29 36.80 6.367 (OUT) Pre-MainPool Pre- 25yr 24hr 25 -0.943 730.75 -19.40 (N/A) (N/A) (Reverse) Pre-MainPool Pre- 50yr 24hr 50 11.749 738.50 55.42 (N/A) (N/A) (IN) Pre-MainPool Pre- 50yr 24hr 50 8.888 768.00 28.91 36.92 6.638 (OUT) Pre -Main Pool Pre- 50yr 24hr 50 -1.021 718.75 -16.20 (N/A) (N/A) (Reverse) Pre -Main Pool Pre- 100yr 100 15.193 734.50 64.48 (N/A) (N/A) ;IN) 24hr Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppe 2/9/2018 DUI MCADAMS Subsection: Master Network Summary Pond Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (min) (ft3/S) (years) (ac-ft) Pre-MainPool (OUT) Pre-MamPool (Reverse) Ditch #6 (IN) Ditch #6 (OUT) Ditch #6 (IN) Ditch #6 (OUn Ditch #6 (IN) Ditch #6 (OUn Ditch #6 (IN) Ditch #6 (OUT) Ditch #6 (IN) Ditch #6 (OUT) Ditch #6 (IN) Ditch #6 (OUT) Ditch#7 (IN) Ditch#7 (Reverse) Ditch#7 (OUn Ditch#7 (IN) Ditch#7 (Reverse) Ditch#7 (OUT) Ditch#7 (IN) Ditch#7 (OUT) Ditch#7 (IN) Ditch#7 (OUT) Ditch#7 (IN) Ditch#7 (OUT) Ditch#7 (IN) Ditch#7 (OUT) Hamilton -Hurst Pai UNW17060.ppc Pre- 100yr 24hr Pre- 100yr 24hr Pre- lyr 24hr Pre- lyr 24hr Pre- 2yr 24hr Pre- 2yr 24hr Pre- 10yr 24hr Pre- 10yr 24hr Pre- 25yr 24hr Pre- 25yr 24hr Pre- 50yr 24hr Pre- 50yr 24hr Pre- 100yr 24hr Pre- 100yr 24hr Pre- lyr 24hr Pre- lyr 24hr Pre- lyr 24hr Pre- 2yr 24hr Pre- 2yr 24hr Pre- 2yr 24hr Pre- 10yr 24hr Pre- 10yr 24hr Pre- 25yr 24hr Pre- 25yr 24hr Pre- 50yr 24hr Pre- 50yr 24hr Pre- 100yr 24hr Pre- 100yr 24hr ding Lot 100 100 11 1 2 2 10 10 25 25 50 50 100 100 1 1 1 2 2 2 10 10 25 25 5o 50 100 100 12.474 749.75 31.14 -1.230 698.50 -12.94 1.607 749.00 9.79 1.365 758.75 8.94 2.655 744.50 18.90 2.233 757.25 16.44 6.925 740.25 51.51 6.398 747.25 28.39 10.551 740.25 74.87 10.012 735.50 27.70 14.063 740.25 94.69 13.514 729.25 26.19 18.239 740.25 115.61 17.662 721.25 24.06 0.337 735.25 2.80 -0.007 1,270.25 -0.50 0.000 0.00 0.00 0.691 757.50 4.16 0.000 1,257.75 -0.14 0.000 0.00 0.00 8.426 803.25 25.84 7.524 839.75 21.66 15.411 768.00 38.25 14.500 799.50 32.47 22.131 755.00 47.22 21.210 791.00 38.64 29.931 741.50 50.84 28.969 788.50 40.18 Maximum Water Surface Elevation (ft) 36.97 (N/A) (N/A) 35.72 (N/A) 36.31 (N/A) 37.01 (N/A) 37.06 (N/A) 37.12 (N/A) 37.18 (N/A) (N/A) 35.72 (N/A) (N/A) 36.30 (N/A) 36.63 (N/A) 36.78 (N/A) 36.89 (N/A) 36.93 Maximum Pond Storage (ac-ft) 6.742 (N/A) (N/A) 0.242 (N/A) 0.422 (N/A) 1.328 (N/A) 3.390 (N/A) 5.623 (N/A) 8.256 (N/A) (N/A) 0.334 (N/A) (N/A) 0.692 (N/A) 1.038 (N/A) 1.256 (N/A) 1.419 (N/A) 1.466 R. STUBBS, El 2/9/2018 0 0 0 q a m 0 a 8 0 I 2 18 14 5 6 7 8 \ , 1 z �a/ / \ \ \� �\ J // , _ - # 17-17725-01 \\\I ` r� \ I 'v-/- -////f I / I / r\ � \ \\�\`'\\\ \ //�//� =-//J/ \\ \ \ 1 / / I /-� //' / / � \ l 11A / UNCW PROPERTY LINE �,X\.-`\ ;` \ � I ' - r - / / \ / � 1 _ \ \\ \\ \� llli/�11 - - _ / // / toil \ J "\\, , ) / r 1 l // / l I \ \ I \\�\ / 111\\�_ - % f/ ) ; �') a 1 `�\\\\(, ,, \ / i // / // (/' l ,--' I - / I,_ ) \ \\ \ l //, 11\�\\ ' / /f / //' /01 _^/\,11 / , � I � - - 9 _ f \ f \-,` 1 ( l \) I //1/ // ;r f,. Jam_; \ // / /// i \ ,i ' i 1 \ \ ; r 2 /f ;u / / \ l /// / / / l / / � / /' l n - r n� - \V/i - \ \ /. -0, ` - r ( l , / !/// % J/, / ! ,_ / ram. _ \ \ lil1 `�/ IIIWj n \ ;r_ }!.-. J/!I }�-v--J ,a -:\f ? i \ y\// of/(I / �, / /.'�. /a / .•__..-1 ice/ �\,,-_ \ l / I //s!/ /�/%,< �'l'�`I ( j/ �J / _ ^C. ^r, \� \ \ 1 0 �%% ,4 /a-J/1 _ '.". _ "_ - ) \.'- / j"_Y �. / ��i I I / ( .w _ ..� c -� / / L \ 1 /I ( ) //�j /////� / f \ /'/ Ps�(� / \\�l/J - v l\ off/ ��' `` t A <,,✓ ,. I \,,,, �cs- , �._ ~.,. .`:,...'-mot-... s^- ,"l"<. /, i � � �� ,� .., .:, / >:. ) / -,,`, / / I / / //�///ice/,,�i/i�a/,. ,� / ).t%-`J ' %� ^•v` �J�,� \�)J�.n 1. \a --\ �""7 /"_�-� I / �. s-/ �' I : I 11 / /'; \, / \>"\- \ -,� --` / ////{//// _/ //f / , ' <I�?/ J , \1 o A ' / S �/ / ) / \ - t 11 �� i' 1 \ .\ \ / ` �'' i I I r ) z / / ( i / /, / ///// /, /�((( ! (( f /1 ' z l) I (-_, =., C 1 / e \ J ( -' S� � 11 11� l , ,' , / .( " \ " j ,( \y� i l 1 J / i , f / ( \ ( \ / l ( /�//// -/ , i / 1 � // % \ _ �/ c� 0. / < �` \ _ l / 1 // 9 � \ ` J` ...�,`- �{'. - ( i o / I:. .- \I /'� / ,J.,,. /I /� / / /�% ///' %/ -�,/// - C, 1V \�J, a a 'C\ i�/b� c\ ° <v'' '' uu , _. . .y' tom' n -, r a / o i / O / �, J J i ,\/ ��`' 1'1 iI 7.( / / / / r / ri//////// ♦ c LIP �\\ jJ / / n\> o �G / /fir_ t / / / - ( - / / - // / / , <L o r , oS TJO J - v J ' 11 r `, / y / �. \ ) / i\ J 1, J/ ! / / / / ///J//! / /�-/ I ( C �r r� v % °-' ti \ `, f, ,, - 1 I _t \ 1 i ") ) \ / / f;/ ////�/il 1- I / (? D��\ ` \Jg C / , \ l < \ \ J \ / ! / / / psi f , , / / ) z o 0 i( `�A /` d Q J / / ". (4_ / \�: �\ l \\c\ t \ '`"( \.__ J /\_, ter/ ,<,, i �ii/ // \ \g, �� 4l> o o/ . I -Si 1 / / / / I/ //, I -.1 .\ Z/ s -i -3 - / / r \1;1 �• \ \ \-.'=w'�•-'� (/ - a -� 1 ' ~` �,. , =� =, \.�_.1 \ \ �- I I ( / --„ \ - / r` '� l .- ,. // ., /->-///�i %`�' /. / ' / / / i -._ __ ` \ G 1 I ��) ( �) (-v v4`7 " ( �'' -„�i / / ;. \ \ / " i„ -//ice/ r / / / ` / / i --Vc p o /--� /� o\ /> 6- , 11 ✓I / � I ",,- , . \�11 \\' \ ' \ \ l )</ \ \ / /l f / ' y l -' \-Oj \~ _ ✓ o ,�-ti. q `/) - \ r.' f \ 1�1�- -,� \ \\may\ \\` \ - /. / // �. —/� / �v �S j- I( r\ -,j -, 0 -/ ' - >: / \ � a ' -' , . j-- ( - ,- t '7• �:\- � \ 11 ) 7 1 - \ / / / i / / / / f - \ 1 1) a J l C� ✓ 4 J ( of n I. '!- !�J- -:,, \ 11?\ ,, \ \\ / \\- i` -- � /�/ /-' / � -- —� \/1 %�' S \o o a J 1, ! ^` � - \ I SUB TO DITCH #6 t 1; ` /1- / z. / \ —. / n v ,- \` ., \ \ \ % -- r �_�' —i � , — / � r / f i J \ ( c O (\� li — 0 0 �� _� �� \ C ` , `- I / j4� /_/, /,: \ -ww, \ AREA - 32.04 AC ! �. - \ t i�t,rd \ �� _\"�"'>:,\�\\J �_�-\ `_;\..11 .�.��%���� //:T.. / i / // t, �^ ): \' mot: Op 7('�/Ifd ra\P n r.ln s c�� '\%^ , / > C, . ". /. I J:,:{'`.,:' .�.,, \._- �\,-� \' `` `� _:_\ t :, -_�1' "—� {��� �; i i/ r -�-.,, ) J (� l' \ ', �/, \!--')(/ `' \/'� - / t'`P �'Q � IQP' �� b \ //�/, \ n %, f .. \ \,_ .'��/ \ .;/ / % _ \ - - , l �-'\- \ �` '` \ -.,�r� .. h _ i �� '� ` \ ( \ 1' ( ) �-) / — -'- �\ ( \ i `o ,� fj '�G \ �_ i G � \� \; f -. - ,�, " \ L% / p, \ \..,.- � >;„ \ '\ = I, - / /'. / ( / r ) / / f /; \ a vti ) \� a o CI c C> > �- I / ' R-. M ��'\ '.'_ \ / ;n 1 .,,. . - _-... - `. ; _ — - / .ice \ (� J _ \-- _ ,°> +-, i G a \ F �- 1, -"> :.. I \ �,�� J ✓ �.,I 1 �► ",_G' r ,r/ / / .1 )V /C ot�- l . } % �~ V / ,.- ; i� •.,. / _ \`.. _ - ` �c - % ,�♦r > 1- - ) ) - / \ -/ \ ' `A � _ 7,� ° d i ° o D o - 7 ` __' _ i . � ;: % / ( P ` 1 � �— i � 1 / / / O / a ' i.' nog w > z / / ( \ ._. i ph 40k't I - . / / F ,+;fy/ "' t-3 r 't ./l /. I V--- 'eN�',� S �- �e`.�: / "' / / / ( / _ _ _ \ \-: \ L L / �S I / �; \ IJ �.,�� (�� \_� �/ t. / .. f .. ') l- : , ( I ..,� ,\ .,�.,- _ Y-— , -' , , ? t. \ / / / \ - \ l O °C / _ � � 1 P l 1 l ° . f !, / r;' off; \ / =� \ /,. \ / - 1. r,- / � "' % / -:, � Fi- . / i / / f ^� / \ \\\�\ a --T ,q•D <; t - . � \ - \ f / r� - .� - \- \ IF e {' n. _\ „: // I / \ / ♦ ` ..< - '/ / j \ l / l I �( f \ \ =�:. ( a \ ' v cam'' C n �,_ n ' I / ` J r / \ n- v \\ ! / j J /, 1 -4 / / " `,, ve .°, f / i I /\ \ \ S3 \ s J ) \� tj I -1 \ / t..- .' // -� /-1 - , /', / ` / `:.' ''.�,:. 'I i /�. - L`' '-.....,.n S? / f-,t.... � ;.. "' a. a. - '.,, ,.. r .r, i _ Ar -� \ `�\ \ 1� zII6/ I _, \ \ / , % \ 1 \- ./ r .., \ 2 �> ram- - _ `< ArH , - • , ^ \ _. ♦ -.,.11', \`a / / / / r t "` l,' _ \, \ l , S z\ /. 1 ,, / \ i / / , / 1 , v / / / (i \ \ t -' - " ` \ \\\ ` I-- 1 . � \T' \ , /% / �, ` \ `, / -ems I ) / w ON\ \ \ 1 _ / - f i i \ �� '.._, � -,.... \.. ?:(.,/..,/ �. _' �� I' \ � %SN a / ,". ?% 1' ' •,... r '' :.'. -- - .... \ >/ 1.% �.' ~. / \ DITCH //6 / :,\ ,% i'' /\ c ! a _- `` \ / • / Via,- \ i . S ,. \ \ \ a f :-: \ i \ \ SUB TO FOREBAY _-,' - � i -_` 7 1.; /,, � � / / / ^\ (, � \\�� � ti \ \ . t \ \ ' AREA 19.22 AC } \ , / ; \ � ♦ ( \\ . r \� ��,, s11 r. \ !\ f rI \� ,� , , - %/ // ' / / 4` f -,\ \ �\\ " y > � / / .- UNCW PROPERTY LINE �\� 'l � I I ' ` \ � / 1 // // / / c / / \ \\\ \ / �� \ �, % �� k � v - // %/ / - v v, ` l /, f-� y//��/ / / 1 ♦ / O 1.�111A ti __ - - 3. .) - .: 3- \ 1 v� ,-"f : , l / /�//// \1\ / J SUB TO MAIN POOL v \) ✓lJ ' a ,.\ � *\. !. \\\ \ � \ \,; - 1 f _�. �, "„ s � .,. �1-,-;,..r��''� S -� >,r / ///// FOREEIAY EXISTING I�.. '% \ �� ,- 1 ,/„�� �, i ,It � \ \ \ - \ I 'I l^ \ % r / // / AREA = 5.17 AC \\ \ Iti \ \' /` 1 \ 1 \" \ ✓ \ \ f / 1, \ .I ��, a /l / \\ \) /'III II /�/ '1 : - \ /- I 1-v,vv o �/�1( / F I,� -, Gb �\ \ � \\ \\ 7 T /� ' / ! `d � I -/ , / I)1\I ` / -- ,�r l /%" _ ',mil \,' ^s.\ / _i\\ '' ,. _"���\��'\\\ \ \� \ 1� /„... +x '<` UNCW PROPERTY LINE \ -1 I�� \ \ / \ \ . \ -, _ f /1 �� \-:..., ,� "�'...-1 I - ,, i _�( ) r / r tea. \�\\ -r,_ /!1 S' J_' \.\� \ \ \\\\... \� .::../ /../ � ') -' \\ _ r \ r r 4 / .,1„ \\\ \ \ \\. � \ L _..\ _ J I:, /' \ — _ ' I I (,..\.:: _....�L 4, - �' _. ti. °mil\ I f E,��'" a l/Jl / (/ / �� \ \\- - \�, \ _ \ \ � \ �\ \ (, \ ��,\ ,,,\\ , .>' ) �,- 1 // ` EXISTING \ \\ ✓ , \ \ ' �, \' ( \ \%. \` /., f ( \\\ MAIN POOL 7), / E \ F tIt ( ( \ \ \ ` 37 y % " \ \_ _ // -� \' \ \ \ ( I — 1• �, /,? (, .52, /1 - y. ./ _`\�/ /jam/�j4/4/ r St, \ — \ \ \ \ ) I \ ,ri ti o l ? \\ \ ` ///xz//♦♦ jam f,- vv \ v \ / /. 77% v Z, / . E ' �� ��` vV 11�` y //7 1 �v ♦ I' � r )�\\ v t, VA- v \ f/ Q e / / / r �/ U \ v vI'llvv _ y. / [ / �f /'1.0 ate l l v J /i � ` ..,, - \ \ \ __ 4 \ \_ \ �/r /r / 1► / , , ` % - f Q ram` S \ \\ / � ' # / I - p,� �II v v II v ��v A-, * 8 v :�v P �Q w, o" x v //' l / JO >% (o> 5 / /i II v�v-4o -, .�. \- ��s�/ // //, z \ / \_ vv . , rI f Y 1 i/ gym\ �. 1 \ \ \ i \ - - // Y ) "/ , Z z / l \ z ,IF A 0 I 1 2 2-,� .� v -- I V v_ ,,/, / / 11 v/, ei e / `� E� � J'r:za.'>4`sS : v v \.�A a c \ V -r v .f sa I _ �/ / �� / _ je \ , IAi - SUB TO DITCH 7 /i o # e`l \ \~ ,.. '// AREA = 2.54 AC r -, - v v �v , -, � , v /� � \ v v vv v - y, v v 111. �, v= v v v- �F G 1 I _ _ __ OVERALL POINT OF ANALYSIS \ _ 1��°j , -_, - 3 1 4 1 5 1 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION 6 1 7 1 8 Gl ■ m CI E7 ■ LA FI m I. I,'N ig 4 � $ to $ 3L r^ � V) mmi411� 2 A =1 4< V 6i z 0 U) 5 : FA Q O Q Cat d O OLD a 1 m O e" cw 0 aN zap a0z �--xz E O z�E �mz w O O o �:- p � I Ouz ZZo 9 w 0;1- QI 0.4 � 2 RZ o A oo C7 z 4!� H 2, 4` s F�1 O E A 0 �:)U a PROmT NO- UNW-17060 Fn.NAmE: UNW17060-PRE CHECKED BY: DAP DRAWN BY: RAS SCALE: 1" = 100' DATE: 1-10-18 SHEFT NO. PRE 'J MCADAMS POST -DEVELOPMENT HYDROLOGIC CALCULATIONS UNCW - HURST HAMILTON PARKING LOTS UN W-17060 UNCW HURST HAMILTON PARKING LOT POST -DEVELOPMENT HYDROLOGY R. STUBBS, El U N W-17060 Summary of Results 2/9/2018 HYDROLOGY INPUT SUMMARY Onsite Area [acres] Offsite Area [acres] Total Area Sub -basin ID Impervious Open Wooded Pond Total Impervious Open Wooded Pond Total [acres] SCS CN Tc [min] Main Pool 4.95 1.96 0.39 0.95 8.25 0.22 0.28 0.00 0.00 0.50 8.75 82 25.37 Forebay 8.79 9.49 0.00 0.45 18.73 0.00 0.50 0.00 0.00 0.50 19.23 74 23.41 Ditchl 2.30 3.75 0.00 0.00 6.05 0.00 0.00 0.00 0.00 0.00 6.05 68 18.10 Ditch2 2.92 7.58 11.97 0.00 22.46 0.00 0.09 0.78 0.00 0.86 23.33 58 32.56 Ditch3 0.09 0.14 0.00 0.00 0.24 0.00 0.03 0.00 0.00 0.03 0.26 71 5.00 Ditch4 0.09 0.44 0.00 0.00 0.54 0.01 0.08 0.00 0.00 0.09 0.63 52 5.00 Ditch5 0.33 0.27 0.00 0.00 0.60 0.01 0.17 0.00 0.00 0.18 0.78 71 5.00 Totals = 19.48 23.63 12.36 1.39 56.87 0.24 1.14 0.78 0.00 2.17 59.03 UNCW HURST HAMILTON PARKING LOT POST -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW-17060 Sub t0 M010 Pool 2/9/2018 I. SCS CURVE NUMBER$ Assume: HSG Impervious Open Wooded A 98 39 1 30 B 98 61 55 C 98 74 70 D 98 80 77 HSG'A' = 64.2% HSG'B'= 35.8% HSG'C' - 0.0% HSG'D'= 0.0% ' Cover Condition SCS CN Comments i Impervious 98 Open 47 Assume good condition Zen 39 Assume good condition 11. POST -DEVELOPMENT Watershed Breakdown Contributing Area SCS ON Areas Area acres Comments I Onsite impervious 98 215,633 4.95 Onsite open 47 85,372 1.96 Assume good condition Onsite wooded 39 17,112 0.39 Assume good condition Onsite pond 100 41,263 0.95 Offsite im erwous 98 9,554 0.22 Offsite open 47 12,323 0.28 Assume good condition Offsite wooded 39 0 0.00 Assume good condition Offsite pond 100 0 0.00 Total area 8.75 acres 381,257 sq. ft. Composite SCS ON = 82 % Impervious = 59.1% UNCW HURST HAMILTON PARKING LOT POST -DEVELOPMENT HYDROLOGY R. STUBBS, El UN W-17060 Sub to Main Pool 2/9/2018 Ill. TIME OF CONCENTRATION INFORMATION Time of concentration is calculated using the SCS Segmental Approach lTR.551. Segment 1: Overland Flow Segment 2: Concentrated Flow Length= 100 If Length= 300 ft Top Elev= 38.5 it Tap Elev= 36.50 It Bot Elev= 36.5 it Bot Elev= 36 ft Height= 2 ft Height= 1 ft Slope= 0.0200 ft/ft Slope= 0.0017 ft/ft Manning's n= 0.40 wooded, dense underbrush Paved?= No P (2-year/24-hour) = 4.70 inches (Wilmington, NC) Velocity= 0.66 ft/sec Segment rime= 17.72 minutes Segment lime= 7.59 minutes Segment 3: Pipe Flow Length = 18 It Top Elev= 36 Bot Elev= 35.75 Height= 0.25 ft Slope= 0.0139 ft/ft Mannings n= 0.013 concrete Flow Area= 0.79 sf(assume 12"RCP) Wetted Perimeter= 3.14 If (assume 12" RCP) Channel Velocity= 5.36 ft/sec Segment rime= 0.06 minutes Time of Concentration= 25.37 minutes SCS Lag Time= 15.22 minutes (SCS Lag =0.6-Tc) Time Increment= 4.41 minutes (=0.29-SC5 Lag) UNCW HURST HAMILTON PARKING LOT POST -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW-17060 Sub to Forebay 2/9/2018 1. SCS CURVE NUMBERS Assume: HSG Impervious Open Wooded I A 98 39 30 B 1 98 61 55 C 98 74 70 D 98 80 77 H5G'A'= 43.1% HSG'B'= 56.9% HSG'C'= 0.0% HSG'D'= 0.0% Cover Condition SCS CN Comments i Impervious 98 Open 52 Assu me good conditi on Wooded 44 Ass a me good cond iti on It. POST -DEVELOPMENT Watershed Breakdown Contributin Area SCS CN Area acres Comments 1 Onsite impervious 98 8.79 Onsite open 52 9.49 Assume good condition Onsite wooded 44 DAD Assume good condition Onsite pond 100 E1,9 0.45 Offsite impervious 98 0.00 Offsite open 52 0.50 Assume good condition Offsite wooded 44 0.00 Assume ood condition Offsite and 100 0.00 Total area= 19.23 acres 837,646 sq. k. Composite SCS CN= 74 % Impervious = 45.7% UNCW HURST HAMILTON PARKING LOT POST -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW-17060 Sub to Foreboy 2/9/2018 Ill. TIME OF CONCENTRATION INFORMATION Time oJconcentration is calculated using the SCS Segmental Approach (TR-55). Segment 1: Overland Flow Length = Top Elev = Bot Elev = Height = Slope = Manning's n = P (2-year/24-hour)= Segment Time= Segment 3: Pipe Flow Length = Top Elev = Bot Elev = Height = Slope = Manning's o = Flow Area = Wetted Perimeter= Channel Velocity= Segment rime = Segment 2: Concentrated Flow 100 it Length = 235 it 41 R Top Elev= 40.5 it 40.5 ft Bot Elev= 37.9 it 0.5 it Height= 3 it 0.0050 Wit Slope= 0.0111 Wit 0.24 dense grass Paved?= No 4.70 inches (Wilmington, NC) Velocity= 1.70 ft/sec 20.50 minutes Segment Time 2.31 minutes 358 fit 37.9 34 3.9 it 0.0109 Wit 0.013 concrete 1.77 sf (assume 18" RCP) 2.36 If (assume 18" RCP) 9.88 ft/sec 0.60 minutes Time of Concentration= 23.41 minutes SCS Lag Time= 14.05 minutes SCS Lag =0.6-Tc) Time Increment= 4.07 minutes 1=0.29'SCS Lag) UNCW HURST HAMILTON PARKING LOT POST -DEVELOPMENT HYDROLOGY R. STUB85, El UNW-17060 Sub to Ditchl 2/9/2018 1. SCS CURVE NUMBERS Assume: HSG Impervious Open Wooded ' A 98 39 30 8 98 61 55 C 98 74 70 D 98 Bo 77 HSG'A'= 48.2% HSG'B'= 51.8% H5G'C'= 0.0% HSG'D'= 0.0% Cover Condition SCS CN Comments i Impervious 98 Open 50 Assume good condition Wooded 43 Assume good condition II. POST -DEVELOPMENT Watershed Breakdown Contributing Area SCS CN Area Area acres Comments Onsite impervious 98 100,155 2.30 Onsite open 50 163,426 3.75 Assume good condition Onsite wooded 43 0 0.00 Assume good condition Onsite pond 100 0 0.00 Offsite impervious 98 0 0.00 Offsite open 50 0 0.00 Assume good condition Offsite wooded 43 0 0.00 Assume good condition Offsite pond 100 0 0.00 Total area = 6.05 acres 263,581 sq. R. Composite SCS CN = fib %Impervious= 38.0% UNCW HURST HAMILTON PARKING LOT POST -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW-17060 Sub to Ditchl 2/9/2018 III. TIME OF CONCENTRATION INFORMATION Time of concentrotion is colculoted using the SCS Segmental Approach (TR-55). Segment 1: Overland Flow Segmeat2: Conrentroted Flow Length= 100 8 Length= 513 ft Top Elev= 42.00 it Tap Elev= 39.00 ft sot Elev = 39.00 It Bot El" = 36.40 ft Height= 3 it Height= 3 ft Slope= 0.0300 ft/ft Slope= 0.0051 ft/ft Manning's a= 0.24 dense grass Paved?= No P (2-year/24-hour) = 4.70 inches (Wilmington, NC) Velocity= 1.15 ft/sec Segment Time 10.01 minutes Segment Time= 7.44 minutes Segment 3: pipe Flow Length = 164 it Top Elev= 34.37 Bot Elev= 34.04 Height= 0.33 ft Slope= 0.0020 ft/ft Manning's n= 0.013 concrete Flow Area= 1.77 sf(assume 18"RCP) Wetted Perimeter= 2.36 If (assume 18"PCP) Channel Velocity= 4.24 ft/sec Segment Time= 0.64 minutes Time of Concentration= 18.10 minutes SCS Lag Time= 10.86 minutes (SCS Lag =0.6-Tel Time Increment= 3.15 minutes 1=0.29-SCS Lag) UNCW HURST HAMILTON PARKING LOT POST -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW- 7060 Sub to Ditch2 2/9/2018 Assume: HSG Impervious Open Wooded I A 98 39 30 B 1 98 61 55 C 98 74 70 D 98 80 77 HSG'A' = 21.7% HSG'B'= 78.3% HSG'C'= 0.0% H5G'D'= 0.0% Cover Condition SCS CN Comments Impervious 98 Open 56 Assumegood con dition Wooded 50 Assume goad condition II. POST -DEVELOPMENT Watershed Breakdown Contributing Area SCS CN Area (sq Area acres Comments I Onsite impervious 98 127,154 2.92 Onsite open 56 330,098 7.58 Assume good condition Onsite wooded 50 521,308 11.97 Assume good condition Onsite pond 100 0 0.00 Offsite impervious 98 0 0.00 Offsite open 56 3,710 0.09 Assume good condition Offsite wooded 50 33,968 0.78 Assume good condition Offsite pond 100 0 0.00 - Total area= 23.33 acres 1,016,238 sq. R. Composite SCS ON = 58 % Impervious = 12.5% UNCW HURST HAMILTON PARKING LOT POST -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW-17060 Sub to Ditch2 2/9/2018 III. TIME OF CONCENTRATION INFORMATION Time of concentration is calculated using the SCS Segmental Approach ITR-55). Segment 1: Overland Flow Segment 2: Concentrated Flow Length= 100 it Length= 762 it Top Elev= 42.00 it Top Elev= 40.00 it But Elev= 40.00 it Bot Elev= 36.28 it Height= 2 it Height= 4 ft Slope= 0.0200 ft/ft Slope= 0.0049 ft/ft Manning's n= 0.40 dense grass Paved ?= No P (2-year/24-hour) = 4.70 inches (Wilmington, NC) Velocity= 1.13 ft/sec Segment Time 17.72 minutes Segment Three = 11.27 minutes Segment 3: Pipe Flow Length= 665 It Top Elev= 33.91 Bot Elev= 33.00 Height= 0.91 It Slope= 0.0014 ft/ft Manning's n= 0.013 concrete Flow Area = 1.23 sf (assume 15" RCP) Wetted Perimeter = 1.96 If (assume 15" RCP) Channel Velocity= 3.10 fit/sec Segment Time= 3.58 minutes Time of Concentration= 32.56 minutes SCS Lag Time= 19.54 minutes(SCS Lag =0.6-Tc) Time Increment= 5.67 minutes )=0.29-SCS Lag) UNCW HURST HAMILTON PARKING LOT POST -DEVELOPMENT HYDROLOGY R. STUBBS, EI UNW-17060 Sub to Oitch3 2/9/2018 I. SCS CURVE NUMBERS Assume: HSG Impervious Open Wooded A 98 39 30 B 98 61 55 C 98 1 74 70 D 98 1 so 77 HSG'A'= 21.0% HSG'B'= 79.0% HSG'C' = 0.0% H5G'D'= 0.0% Cover Condition SCS ON Comments Impervious 98 Open 56 Assume good condition Wooded 50 Assume good condition 11. POST -DEVELOPMENT Watershed Breakdown Contributing AreaM56 Areas Area acres Comments Onsite impervious4,064 0.09 - Onsite open6,233 0.14 Assume good condition Onsitewooded0 0.00 Assume good condition Onsite anda 0.00 Offsiteim ervious39 0.00 Offsiteo en1,156 0.03 Assume ood condition Offsite wooded0 0.00 Assume ood condition Offsite and0 0.00 Total area= 0.26 acres 11,492 sq. ft. Composite SCS ON = 71 % Impervious = 35.7% Time o)concentration is calculated using the SCS Segmental Approach (TR-55). Time of Concentration= 5.00 minutes SCS Lag Time= 3.00 minutes)SCS Lag =0.6•Tc) Time Increment= 0.87 minutes )=0.29-SCS Lag) UNCW HURST HAMILTON PARKING LOT POST -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW-17060 Sub t0 Ditch4 2/9/2018 1. SCS CURVE NUMBERS Assume: HSG Impervious Open Wooded A 98 39 30 B 98 61 55 C 98 74 70 D 98 80 77 H5G'A'= 79.9% HSG'B'= 20.1% HSG'C'= 0.0% HSG'D'= 0.0% Cover Condition SCS CN Comments I Impervious 98 Open 43 Assume good condition Wooded 35 Assume good condition IL POST -DEVELOPMENT Watershed Breakdown Contributing Area SCS ON Area 5 Area acres Comments Onsite impervious 98 4,010 0.09 Onsite open 43 19,383 0.44 Assume good condition Onsite wooded 35 0 0.00 Assume good condition Onsite pond 100 0 0.00 Offsite impervious 98 543 0.01 Offsite open 43 3,464 0.08 Assume good condition Offsite wooded 35 0 0.00 Assume good condition Offsite pond 100 0 0.00 - Total area= 0.63 acres 27,400 sq. ft. Composite SCS CN= 52 %Impervious= 16.6% III._ TIME OF CONCENTRATION INFORMATION Time o com entrotion is calculated using the SCS Segmental Approach (TR-55). Time of Concentration= 5.00 minutes SCS Lag Time= 3.00 minutes (SCS Lag =0.6-Tc) Time Increment= 0.87 minutes (=0.29-SCS Lag) UNCW HURST HAMILTON PARKING LOT POST -DEVELOPMENT HYDROLOGY R. STUBBS, El UNW-17060 Sub to DitchS 2/9/2018 I. SCS CURVE NUMBERS Assume: HSG Impervious Open Wooded A 98 39 30 B 1 98 61 55 C 98 74 70 D 98 80 77 H5G'A'= 47.0% HSG'B'= 53.0% HSG'C'= 0.0% HSG'D'= 0.0% Cover Condition SCS CN Comments i _ Impervious 98 Open 51 Assu me good conditi on wooded 43 Assume good condition If. POST -DEVELOPMENT Watershed Breakdown Contributing Area SCS ON Areas Area acres Comments Onsite impervious 98 14,435 0.33 Onsite open 51 11,823 0.27 Assume good condition Onsite wooded 43 0 0.00 Assume good condition Onsite pond 100 0 0.00 Offsite impervious 98 440 0.01 Offsite open 51 7,199 0.17 Assume good condition Offsite wooded 43 0 0.00 Assume good condition Offsite pond 100 0 0.00 - Total area= 0.78 acres 33,897 sq. ft. Composite SCS CN = 71 % Impervious = 43.9% III. TIME OF CONCENTRATION INFORMATION Time o)concentmtion is calculated using the SCS Segmental Approach (TR-55). Time of Concentration= 5.00 minutes SCS Lag Time= 3.00 minutes (SCS Lag =0.6-Tc) Time Increment= 0.87 minutesI=0.29-SCS La 9 MCADAMS Scenario: Post- Development Hamilton -Hurst Parking Lot R, STUBBS, El UN W 17060.ppc 2/9/2018 9 MCADAMS FlexTable: Catchment Table (UNW17060.ppc) Current Time: 0.00 min Notes Label Area SCS CN Time of Concentration W) (min) Pre Sub to Ditch#6 1,395,680 58 32.66 Pre Sub to Ditch#7 110,513 46 25.43 Pre Sub to Forebay 837,341 74 23.41 Pre Sub to MainPool 225,385 57 25.37 Post Sub to Ditch#1 263,581 68 18.10 Post Sub to Ditch#2 1,016,238 58 32.56 Post Sub to Ditch#3 11,492 71 5.00 Post Sub to Ditch#4 27,400 52 5.00 Post Sub to Ditch#5 33,897 71 5.00 Post Sub to Forebay 837,646 74 23.41 Post Sub to Main Pool 381,257 82 25.37 Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppc M12018 !UI MCADAMS Subsection: Master Network Summary Catchments Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (min) (ft3/s) (vears) (ac-ft) Sub to Forebay Post- lyr 24hr 1 2.400 733.50 25.43 Sub to Forebay Post- 2yr 24hr 2 3.386 733.50 36.26 Sub to Forebay Post- 10yr 24hr 10 6.871 733.50 65.02 Sub to Forebay Post- 25yr 24hr 25 9.548 733.50 82.30 Sub to Forebay Post- 50yr 24hr 50 12.024 733.50 95.76 Sub to Forebay Post- 100yr 24hr 100 14.877 733.50 109.19 Sub to Main Pool Post- lyr 24hr 1 1.522 734.00 15.98 Sub to Main Pool Post- 2yr 24hr 2 2.038 734.00 21.24 Sub to Main Pool Post- 10yr 24hr 10 3.776 734.00 33.99 Sub to Main Pool Post- 25yr 24hr 25 5.067 734.00 41.28 Sub to Main Pool Post- 50yr 24hr 50 6.243 734.00 46.87 Sub to Main Pool Post- 100yr 24hr 100 7.585 734.00 52.41 Sub to Ditch#1 Post- lyr 24hr 1 0.566 731.25 6.49 Sub to Ditch#1 Post- 2yr 24hr 2 0.837 731.25 9.90 Sub to Ditch#1 Post- 10yr 24hr 10 1.837 729.00 19.50 Sub to Ditch#1 Post- 25yr 24hr 25 2.631 729.00 25.62 Sub to Ditch#1 Post- 50yr 24hr 50 3.376 729.00 30.42 Sub to Ditch#1 Post- 100yr 24hr 100 4.242 729.00 35.28 Sub to Ditch#2 Post- lyr 24hr 1 1.170 746.75 7.15 Sub to Ditch#2 Post- 2yr 24hr 2 1.933 742.50 13.75 Sub to Ditch#2 Post- 10yr 24hr 10 5.043 742.25 37.44 ;ub to Ditch#2 Post- 25yr 24hr 25 7.683 738.25 54.23 Sub to Ditch#2 Post- 50yr 24hr 50 10.240 738.25 68.76 Sub to Ditch#2 Post- 100yr 24hr 100 13.281 738.00 84.13 Sub to Ditch#3 Post- lyr 24hr 1 0.029 721.50 0.56 Sub to Ditch#3 Post- 2yr 24hr 2 0.042 721.50 0.82 Sub to Ditch#3 Post- 10yr 24hr 10 0.088 721.25 1.50 Sub to Ditch#3 Post- 25yr 24hr 25 0.123 721.25 1.91 Sub to Ditch#3 Post- 50yr 24hr 50 0.157 721.25 2.21 Sub to Ditch#3 Post- 100yr 24hr 100 0.195 721.25 2.53 Sub to Ditch#4 Post- lyr 24hr 1 0.019 726.00 0.17 Sub to Ditch#4 Post- 2yr 24hr 2 0.035 722.75 0.44 Sub to Ditch#4 Post- 10yr 24hr 10 0.106 721.50 1.63 Sub to Ditch#4 Post- 25yr 24hr 25 0.170 721.25 2.50 Sub to Ditch#4 Post- 50yr 24hr 50 0.233 721.25 3.21 Sub to Ditch#4 Post- 100yr 24hr 100 0.309 721.25 4.01 Sub to Ditch#5 Post- lyr 24hr 1 0.085 721.50 1.66 Sub to Ditch#5 Post- 2yr 24hr 2 0.123 721.50 2.43 Sub to Ditch#5 Post- 10yr 24hr 10 0.258 721.25 4.43 Sub to Ditch#5 Post- 25yr 24hr 25 0.364 721.25 5.65 Sub to Ditch#5 Post- 50yr 24hr So 0.462 721.25 6.52 Sub to Ditch#5 Post- 100yr 24hr 100 0.576 721.25 7.48 Node Summary Label Scenario Jverall PDA Post- lyr 24hr Overall PDA Post- 2yr 24hr Return Hydrograph Event Volume ;years) (ac-ft) 1 1 0.000 2 1.166 Time to Peak Peak Flow (min) (ft3/s) u.UU U.UU 1,402.00 2.39 Hamilton -Hurst Parking Lot R. STUBBS, EI UNW17060.ppc 2/9/2018 9 MCADAMS Subsection: Master Network Summary Node Summary Label Scenario Return Hydrograph Event Volume (years) (ac-ft) Overall POA Post- 10yr 24hr 10 10.647 Overall POA Post- 25yr 24hr 25 18.156 Overall POA Post- 50yr 24hr 50 23.054 Overall POA Post- 100yr 24hr 100 26.952 Pond Summary Label Scenario Return Hydrograph Event Volume (years) (ac-ft) Time to Peak Peak Flow (min) (ft3/s) 798.50 25 779.2 28.3.86 19 751.00 28.92 751.50 29.67 Time to Peak Peak Flow (min) (ft3/s) Maximum Maximum Water Pond Storage Surface (ac-ft) Elevation (ft) Post-Forebay Post- lyr 24hr 1 2.400 733.50 25.43 (N/A) (N/A) (IN) Post-Forebay Post- lyr 24hr 1 0.482 742.00 13.77 36.09 2.485 (OUT) Post-Forebay Post- lyr 24hr 1 -0.038 784.75 -0.59 (N/A) (N/A) (Reverse) Post-Forebay Post- 2yr 24hr 2 3.386 733.50 36.26 (N/A) (N/A) (IN) Post-Forebay Post- 2yr 24hr 2 0.974 738.75 19.33 36.53 3.131 (our) post-Forebay Post- 2yr 24hr 2 -0.189 774.00 -2.68 (N/A) (N/A) (Reverse) Post-Forebay Post- 10yr 10 6.871 733.50 65.02 (N/A) (N/A) (IN) 24hr Post-Forebay Post- 10yr 10 4.227 726.50 19.98 36.92 3.752 (OUn 24hr Post-Forebay Post- 10yr 10 -0.006 447.00 -0.04 (N/A) (N/A) (Reverse) 24hr Post-Forebay Post-25yr 25 9,548 733.50 82.30 (N/A) (N/A) (IN) 24hr Post-Forebay Post- 25yr 25 6.860 728.75 18.87 37.04 5.411 (Our) 24hr Post-Forebay Post- 25yr 25 -0.005 382.00 -0.04 (N/A) (N/A) (Reverse) 24hr Post-Forebay Post-50yr 50 12.024 733.50 95.76 (N/A) (N/A) (IN) 24hr Post-Forebay Post- 50yr So 9.188 734.75 24.45 37.07 6.991 (OUT) 24hr Post-Forebay Post- 50yr So -0.006 320.75 -0.04 (N/A) (N/A) (Reverse) 24hr Post-Forebay Post-100yr 100 14.877 733.50 109.19 (N/A) (N/A) (IN) 24hr Post-Forebay Post- 100yr 100 11.962 725.25 20.87 37.11 8.698 (OUT) 24hr Post-Forebay Post- 100yr 100 -0.007 704.00 -0.27 (N/A) (N/A) (Reverse) 24hr Post -Main Post- 1yr 24hr 1 1.967 739.75 27.56 (N/A) (N/A) Pool (IN) lost -Main Post- lyr 24hr 1 0.000 0.00 0.00 36.09 5.381 Pool (OUT) Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppc 2/9/2018 9 MCADAMS Subsection: Master Network Summary Pond Summary Label Scenario Post -Main Post- lyr 24hr Pool (Reverse) Post -Main Post- 2yr 24hr Pool (IN) Post -Main Post- 2yr 24hr Pool (OUT) Post -Main Post- 2yr 24hr Pool (Reverse) Post -Main Post- 10yr Pool (IN) 24hr Post -Main Post- 10yr Pool (OUT) 24hr. Post -Main Post- 10yr Pool 24hr (Reverse) Post -Main Post- 25yr Pool (IN) 24hr Post -Main Post- 25yr Pool (OUT) 24hr Post -Main Post- 25yr Pool 24hr (Reverse) Post -Main Post- 50yr Pool (IN) 24hr Post -Main Post- 50yr Pool (OUT) 24hr Post -Main Post- 50yr Pool 24hr (Reverse) Post -Main Post- 100yr Pool (IN) 24hr Post -Main Post- 100yr Pool (OUT) 24hr Post -Main Post- 100yr Pool 24hr (Reverse) Ditchl (IN) Post- lyr 24hr Ditchl (OUT) Post- lyr 24hr Ditchl (IN) Post- 2yr 24hr Ditchl (OUT) Post- 2yr 24hr Ditchl (IN) Post- 10yr 24hr Ditchl (OUT) Post- 10yr 24hr Ditchl Post- 10yr (Reverse) 24hr Ditchl (IN) Post-25yr 24hr Return Hydrograph Time to Peak Peak Flow Maximum Maximum Event Volume (min) (ft3/s) Water Pond Storage (years) (ac-ft) Surface (ac-ft) Elevation (ft) 1 I -1.192 I 752.25 I -9.32 I (N/A) I (N/A) 2 2 2 10 10 10 25 25 25 50 50 50 100 100 100 1 1 2 2 10 10 10 25 2.823 0.638 1.543 7.997 5.110 -0.876 11.921 9.030 -0.905 15.425 12.653 -1.143 19.540 16.860 -1.293 0.566 0.513 0.637 0.753 1.837 1.819 -0.069 2.631 737.25 1,407.25 743.50 733.75 795.75 735.50 728.75 765.50 723.75 734.75 755.25 720.50 725.25 735.75 708.50 731.25 735.50 731.25 733.75 729.00 Pp411Ki 779.50 729.00 39.46 1.36 -13.78 51.71 15.00 -20.02 56.07 26.35 -22.72 70.95 32.88 -20.21 61.69 35.97 -13.77 6.49 5.73 9.90 8.77 19.50 10.74 -1.14 25.62 (N/A) 36.53 (N/A) (N/A) 36.88 (N/A) (N/A) 37.00 (N/A) (N/A) 37.02 (N/A) (N/A) 37.04 (N/A) (N/A) 36.11 (N/A) 36.55 (N/A) 37.10 (N/A) (N/A) (N/A) 5.943 (N/A) (N/A) 6.403 (N/A) (N/A) 6.602 (N/A) (N/A) 7.426 (N/A) (N/A) 8.496 (N/A) (N/A) 0.053 (N/A) 0.084 (N/A) 0.950 (N/A) (N/A) Hamilton -Hurst Parking Lot R. STUBBS, El UN W 17060.ppc 2/9/2018 9 MCADAMS Subsection: Master Network Summary Pond Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Maximum Maximum Event Volume (min) (ft3/5) Water Pond Storage (years) (ac-ft) Surface (ac-ft) Elevation (ft) Ditchl (OU-0 Post- 25yr 25 2.976 723.50 9.35 37.22 1.963 24hr Ditchl Post- 25yr 25 -0.438 781.25 -4.23 (N/A) (N/A) (Reverse) 24hr Ditchl (IN) Post- 50yr 50 3.376 729.00 30.42 (N/A) (N/A) 24hr Ditchl (OUT) Post- 50yr 50 3.054 717.25 6.80 37.25 2.173 24hr Ditchl Post- 50yr 50 -0.330 755.50 -5.12 (N/A) (N/A) (Reverse) 24hr Ditchl (IN) Post- 100yr 100 4.242 729.00 35.28 (N/A) (N/A) 24hr Ditchl (OUT) Post- 100yr 100 2.235 704.50 5.88 37.25 2.173 24hr Ditchl Post- 100yr 100 -0.172 743.75 -4.86 (N/A) (N/A) (Reverse) 24hr Ditchl (IN) Post- lyr 24hr 1 1.683 739.50 11.97 (N/A) (N/A) Ditchl (OUT) Post- lyr 24hr 1 1.464 751.75 9.98 36.11 0.219 Ditchl (IN) Post- 2yr 24hr 2 2.686 735.00 20.18 (N/A) (N/A) Ditchl (OUP Post- 2yr 24hr 2 2.389 750.00 17.03 36.55 0.297 Ditchl (IN) Post- 10yr 10 6.792 742.25 37.89 (N/A) (N/A) 24hr Ditchl (OUT) Post- 10yr 10 6.486 733.50 23.54 37.11 1.294 24hr Ditchl (IN) Post- 25yr 25 10.222 738.00 54.20 (N/A) (N/A) 24hr Ditchl (OUT) Post- 25yr 25 9.904 726.25 21.00 37.24 2.466 24hr Ditchl (IN) Post- 50yr 50 12.965 738.00 67.41 (N/A) (N/A) 24hr Ditchl (OUT) Post- 50yr 50 11.245 719.25 18.27 37.25 2.521 24hr Ditchl (IN) Post- 100yr 100 15.344 738.00 81.01 (N/A) (N/A) 24hr Ditchl (OUT) Post- 100yr 100 10.871 707.00 16.74 37.25 2.521 24hr Ditch3 (IN) Post- lyr 24hr 1 1.493 751.25 10.12 (N/A) (N/A) Ditch3 (OUT) Post- lyr 24hr 1 1.473 751.75 10.13 36.10 0.020 Ditch3 (IN) Post- 2yr 24hr 2 2.431 750.00 17.23 (N/A) (N/A) Ditch3 (OUT) Post- 2yr 24hr 2 2.402 749.50 17.14 36.53 0.029 Ditch3 (IN) Post- 10yr 10 6.573 733.50 23.94 (N/A) (N/A) 24hr Ditch3 (OUT) Post- 10yr 10 6.543 733.75 22.89 37.00 0.041 24hr Ditch3 (IN) Post- 25yr 25 10.027 726.25 22.22 (N/A) (N/A) 24hr Ditch3 (Otfr) Post- 25yr 25 9.996 726.50 21.17 37.09 0.402 24hr Ditch3 (IN) Post- 50yr 50 11.402 719.25 20.21 (N/A) (N/A) 24hr Hamilton -Hurst Parking Lot UN W 17O6O.ppc R. STUBBS, El 2/9/2018 1111 al McADAMS Subsection: Master Network Summary Pond Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event volume (min) (ft3/s) (years) (ac-ft) Ditch3 (OUT) Post- 50yr 50 11.365 719.50 24hr Ditch3 (IN) Post- 100yr 100 11.067 707.00 24hr Ditch3 (OUT) Post- 100yr 100 11.026 707.25 24hr Ditch4 (IN) Post- lyr 24hr 1 0.286 739.25 Ditch4 Post- lyr 24hr 1 -0.003 955.25 (Reverse) Ditch4 (OUT) Post- lyr 24hr 1 0.163 738.50 Ditch4 Post- lyr 24hr 1 0.000 725.50 (Reverse) Ditch4 (IN) Post- 2yr 24hr 2 1.533 749.00 Ditch4 Post- 2yr 24hr 2 -0.001 773.75 (Reverse) Ditch4 (OUT) Post- 2yr 24hr 2 1.367 750.50 Ditch4 Post- 2yr 24hr 2 -0.001 773.75 (Reverse) Ditch4 (IN) Past- 10yr 10 10.883 799.00 24hr Ditch4 (OUT) Post- 10yr 10 10.719 795.00 24hr Ditch4 Post- 10yr 10 -0.005 722.00 (Reverse) 24hr Ditch4 (IN) Post- 25yr 25 18.295 784.50 24hr Ditch4 Post- 25yr 25 -0.004 723.75 (Reverse) 24hr Ditch4 (OUT) Post- 25yr 25 18.131 787.50 24hr Ditch4 Past- 25yr 25 -0.012 723.75 (Reverse) 24hr Ditch4 (IN) Post- 50yr 50 23.110 755.25 24hr Ditch4 Post- 50yr 50 -0.002 629.50 (Reverse) 24hr Ditch4 (OUT) Post- 50yr 50 22.931 861.00 24hr Ditch4 Post- 50yr 50 -0.005 720.50 (Reverse) 24hr Ditch4 (IN) Post- 100yr 100 26.904 735.75 24hr Ditch4 Post- 100yr 100 -0.001 554.25 (Reverse) 24hr Ditch4 (OUT) Post- 100yr 100 26.719 911.00 24hr Ditch4 Post- 100yr 100 -0.004 558.00 (Reverse) 24hr Ditch #5 Post- lyr 24hr 1 0.248 738.50 (IN) 18.88 17.38 16.65 2.70 -0.24 2.13 -0.03 4.31 -0.51 2.86 -0.33 24.73 23.76 -0.88 34.42 -0.79 28.11 -2.21 40.96 -0.07 28.65 -1.41 42.82 -0.06 28.96 -0.10 2.53 Maximum Water Surface Elevation (ft) 37.12 (N/A) 37.14 (N/A) (N/A) 36.09 (N/A) (N/A) (N/A) 36.53 (N/A) (N/A) 36.86 (N/A) (N/A) (N/A) 36.98 (N/A) (N/A) (N/A) 37.00 (N/A) (N/A) (N/A) 37.02 (N/A) (N/A) Maximum Pond Storage (ac-ft) 0.528 (N/A) 0.609 (N/A) (N/A) 0.126 (N/A) (N/A) (N/A) 0.166 (N/A) (N/A) 0.202 (N/A) (N/A) (N/A) 0.215 (N/A) (N/A) (N/A) 0.218 (N/A) (N/A) (N/A) 0.302 (N/A) (N/A) Hamilton -Hurst Parking Lot R. STUBBS, El UNW17060.ppc 2/9/2018 !J'I MCADAMS Subsection: Master Network Summary Pond Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Maximum Maximum Event Volume (min) (ft3/s) Water Pond Storage (years) (ac-ft) Surface (ac-ft) Elevation (ft) Ditch #5 Post- lyr 24hr 1 0.000 0.50 0.00 (N/A) (N/A) (Reverse) Ditch #5 Post- lyr 24hr 1 0.000 0.00 0.00 36.09 0.248 (OU17 Ditch #5 Post- 2yr 24hr 2 1.489 750.50 3.45 (N/A) (N/A) (IN) Ditch #5 Post- 2yr 24hr 2 0.000 773.75 -0.13 (N/A) (N/A) (Reverse) Ditch #5 Post- 2yr 24hr 2 1.166 1,402.00 2.39 36.51 0.322 (OU77 Ditch #5 Post- 10yr 10 10.972 795.00 23.95 (N/A) (N/A) (IN) 24hr Ditch #5 Post- 10yr 10 0.000 0.50 0.00 (N/A) (N/A) (Reverse) 24hr Ditch #5 Post- 10yr 10 10.647 798.50 23.86 36.65 0.347 (OUT) 24hr Ditch #5 Post-25yr 25 18.483 779.00 28.69 (N/A) (N/A) (IN) 24hr Ditch #5 Post- 25yr 25 0.000 0.50 0.00 (N/A) (N/A) (Reverse) 24hr Ditch #5 Post- 25yr 25 18.156 779.25 28.19 36.71 0.356 (OUT) 24hr Ditch #5 Post- 50yr 50 23.388 753.75 29.72 (N/A) (N/A) (IN) 24hr Ditch #5 Post- 50yr 50 0.000 0.50 0.00 (N/A) (N/A) (Reverse) 24hr Ditch #5 Post- 50yr 50 23.054 751.00 28.92 36.72 0.359 (OUT) 24hr Ditch #5 Post- 100yr 100 27.291 727.50 31.10 (N/A) (N/A) (IN) 24hr Ditch #5 Post- 100yr 100 0.000 0.50 0.00 (N/A) (N/A) (Reverse) 24hr Ditch #5 Post- 100yr 100 26.952 751.50 29.67 36.74 0.361 (OUT) 24hr Hamilton -Hurst Parking Lot R. STUBBS, El UN W 17060.ppc 2/9/2018 F 1 2 3 4 5 6 7 8 c A 1 7,I..=' } \\ / UNCW PROPERTY LINE Z \ \ l // / / r l ) \ � .mom . �s/ / l /affiv /!i /i �ji �i E i,. \ e-.� '9a✓:w ?` /J / —` f 7 1 /./:. / JI J._. :(\ rrr. / \ \ ( //j/ // ./// / ( / /s-cam ✓ i / ° \ \ V� l ,�J'_✓/`.I ( l'/C,:/r`,•\i � ,J' �' I' / Il � / rl IvFri (, �` \ / - v \(` \ / i/) �� �°� /y �i°�V,- - /\f `J. \ \� '� / I )_- f- r I "\_,� l - �. ( / /////jij.., �- //-�:) 1 :I�� /� -'v •`SQL .1) " C\C' vo a-f Ii\ M p1 Ip y(/Za `lip \ r) v C /!` si � � . ( U Z f ....,;.� l///�i/J�//.//a/• j - -1 )//\J//`1 �-//'1 / < U� L )C% �.� -J �„ I. /, / f./. � /. � // L/ ✓ U / � � �' �'lV< �'-r 1' o �'_� � f \• 1 Q (/> /1. _ � /� am e r / /: •. `\`, . / Ifs .-:: I \ t_:,; 4; .,._ �� �\ � \ `='�/ � � r �' \ _ - -`� \ / � Z '/ �, t � I , v � � J . / / r> : , -.-� / / '. � / / / \ SUB —BASIN TO DITCH 2 f ! o \ C, ) may- / \ .� ,� � t � a \. • r? <_ if `-� \\ `--_.,�,fir;//'� \ ,) l J 7 , Oo °i AREA = 23.33 AC # o l o \. � 1 L •�.\ ( ( 1 .- _ `' \ � :~ _- - _ yam' ate" -�x//`� / J / +arc / � / -�2�� �- _C�,e /� �'L o' D i iti�> , �1--)', jr/ / �- � / � (, /: \ ram/ 1\ o'er, ,7� a r' Q a o u. cif `, I ��.- �t`A�� /! SUB —BASIN TO DITCH #1 AREA = 6.05 AC I( , vy� o �O J A-_- :' / l I tk P -.� (.,.- / / . J ,-. At r i J / f J \ \\ SUB —BASIN TO FOREBAY c / - Lf ass L (' _ \ AREA = 19.23 AC ♦� a v POA #1 ,. ,. - \ Ty tip' �c—?�``- \. \ - l ✓ ' \ i / ♦ � .. �1 / / � \ � � -DITCH 2 � \ — // i L / / AV /. .., - \ r/ iii /ice\j. / \ ~ tL \ I S \ j: J / // / i p ^ ' \ C / UNCW PROPERTY LINE \ ` \ �>�A ♦• / —v --- , i SUB —BASIN TO MAIN POOL �7T AREA = 8.75 AC /.POST FOREB / + ✓ rvv v v v y-� \�v )♦ 1 I I( / z //-l� 111 v 40 UNCW PROPERTY LINE ✓ �1►/��/i I �� 1 - � ' '� ♦ `� � / % 1 � � / � —, "'> � \ _ �, � -: T_ y\\v�,��-`; � \ _.\ „♦♦ \ j �� I J \ I I I \ \� \\�,=_ 7`4►.=/ I A \ �-� � bR POA #3 � \ \ \ \ \ \ \�•. L — J SUB —BASIN TO DITCH 3 \\�♦ \ l \\1 \L / POST —MAIN POOL \ ` AREA = 0.26 AC -✓ i \ \ �`♦♦ ,I . 3 gr ♦ I / �: I/ ' \ \ v. \ / 1\ / / s�.o G7 # SUB —BASIN TO DITCH #4 ///, /.�.^f.� I/ TCH4 AREA = 0.63 AC `8 vw ( • `- �,/�� V iJ �l� / - .,�t °' , /�4'' ��a >`\� ."<, SUB —BASIN TO DITCH #5 AREA = 0.78 AC OVERALL POINT OF ANALYSIS (r \J 2 3 I 4 M 7 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION Al Fm ■ cI 17 ■ EI FI co n Nco U W U �z p� �z �S V cri z 0 01 5 a a O A� Okp p„' I CJ pq O E ZQ. "" co a � zoL) �xz �E"O z a O oz O � Z Ooz w Z O w :^ 8 0104 a 5 z A r7 z a z z s O w A 1� 1 PRmcr ND. UNW-17060 MUNAKE:UNW17060-POST CHECK DY: DAP DRAWN BY: RAS SCAB' 1" = 100° DAM 1-10-18 SHM NO. POST 'J McAnaMs STORMWATER CONTROL MEASURE DESIGN CALCULATIONS UNCW - HURST HAMILTON PARKING LOTS UNW-17060 UNCW HURST HAMILTON PARKING LOT STORMWATER CONTROL MEASURE UNW-17060 SSFxn Above NP R. STUBBS, El 2/9/2018 STAGE-STOBAGE FUNCTION COMBINEO7-ABOVE NORMAL POOL ^, Average Incremental Accumulated Estimated Contour Contour Contour Contour Stage Contour Stage Area Area Volume Volume w/S-S Fxn iRrh7i�Flcl•] 3b.UU 2.70 111075 93886 93886 213279 2.63 36.50 3.20 127233 119154 59577 272856 3.21 37.00 3.70 129342 128288 64144 337000 3.81 400000 Storage vs. Stage 350000 300000 y = 64810X1.2116 R' = 0.9969 V 250000 200000 150000 w 100000 50000 0 0.00 1.00 2.00 3.00 4.00 Stage (feet( Ks = 64810 b = 1.2316 STAGE -STORAGE FUNCTION - MAIN POOL& PROPOSWFOREBAYS-,ABOVE NORMAL POOL" Average .Incremental Accumulated Estimated Contour Contour Contour Contour Stage I Contour Stage Area Area Volume Volume w/ S-S Fxn 34.30 1.00 48593 44928 44928 44928 0.74 1.70 51158 3b.5U 3.20 56813 55834 27917 160764 2.09 37.00 3.70 58922 57868 28934 189697 2.39 STAGE -STORAGE FUNCTION -EXISTING FOREBAY (Current,ConCition ) -;ABOVE NORMAL.P,OOL ;:weyY;,; •.'; 1 Average Incremental Accumulated Estimated Contour Contour Contour Contour Stage Contour Stage Area Area Volume Volume w/5-S Fxn PIKIPW 3S.00 1.70 25538 25042 17529 39552 0.67 36.00 2.70 56221 40880 40880 80432 1.19 36.50 3.20 70420 63321 31660 112092 1.56 37.00 3.70 70420 70420 35210 147302 1.9S UNCW HURSTHAM IJON PARKING LOT STORMWATER CONTROL MEASURE UNW-17060 SSFxn Main Pool R. STUBBS, El 2/9/2018 STAGE-STORAGE'FUNCTION NIAIN*POOL Contour (feet) Stage (feet) Contour Area (SF) Average Contour Area (SF) Incremental Contour Volume (CF) Accumulated Contour Volume (CF) Estimated Stage w/S-S Fxn (feet) 26.00 26.50 -0.50 0.00 20,964 21,595 Sediment Storage 28.00 1.50 23,633 22614 33921 33921 1.52 29.00 2.50 25,014 24324 24324 58245 2.48 30.00 3.50 26,414 2S714 25714 83959 3.46 31.00 4.50 27,838 27126 27126 113085 4.46 32.00 5.50 29,281 28560 28560 139644 5.49 33.00 6.50 30,782 30032 30032 169676 6.55 area and volume used for avg. depth calculation Storage vs. Stage 200000 180000 - Y = 21394X11019 160000 R2 = 0.9997 140000 U 120000 - 100000 N o e0000 N 60000 40000 20000 0 0.00 2.00 4.00 6.00 &00 Stage (feet) Ks = 21394 h = 1.1019 UNCW HURST HAMILTON PARKING LOT STORMWATER CONTROL MEASURE UNW-17060 SSFxn Existing Foreboy - Current Condition R. STUBBS, El 2/9/2018 STAGE -STORAGE FUNCTION FOREBAY Contour Contour Contour Contour Stage Contour Stage Area Area Volume Volume w/5-S Fxn (feet) (feet) (SF) (SF) (CF) (CF) (feet) 29.00 -1.25 9,132 Sediment Storage 30.25 0.00 11A72 32.00 3.00 16,021 14812 14812 24363 3.17 33.00 4.00 18,557 17289 17289 41652 3.92 33.30 4.30 19,500 19029 5709 47360 4.13 Storage vs. Stage 60000 - 50000 y = 1343.5x25132 R2 = 0.9771 u 40000 U W 30000 N O � w 20000 - 10000 0 0.00 1.00 2.00 3.00 4.00 5.00 Stage (feet) KS = 1343.5 b = 2.5132 UNCW HURST HAMILTON PARKING LOT STORMWATER CONTROL MEASURE UN W-17060 SSFxn Proposed Foreboy p1 R. STUBBS, El 2/9/2018 STAGE -STORAGE FUNCTION FOREBAY Average Incremental Accumulated Estimated Contour Contour Contour Contour Stage Contour Stage Area Area Volume 'Volume w/ S-S Fxn (feet) (feet) (SF) (SF) (CF) (CF) (feet) 27.50 -0.50 1,758 Sediment Storage 28.00 0.00 2,210 29.00 1.50 3,160 2685 2685 2685 1.50 30.00 2.50 4,181 3671 3671 6356 2.51 31.00 3.50 5,264 4723 4723 11078 3.48 32.00 4.50 6,401 5833 5833 16911 4.48 33.00 5.50 7,701 7051 7051 23962 5.51 33.30 5.80 8,081 7891 2367 26329 5.83 30000 25000 - Storage vs. Stage y = 1353.5x' �2 R' = 0.9999 u. 20000 U 15000 N O w 10000 - - 5000 0 2.00 4.00 6.00 8.00 0.00 Stage (feet) Ks = 1353.5 b = 1.6942 UNCW HURST HAMILTON PARKING LOT STORMWATER CONTROL MEASURE R. STUBBS, El UNW-17060 SSFxn Proposed Forebay R2 2/9/2018 STAGE -STORAGE FUNCTION-FOREBAY - Estimated Average Incremental Accumulated Contour Contour Contour Contour Stage Contour Stage Area Area Volume Volume w/5-S Fxn (feet) (feet) (SF) (SF) (CF) (CF) (feet) 29.00 -0.50 192 Sediment Storage 29.50 0.00 271 30.00 1.00 383 327 164 164 0.99 31.00 2.00 631 507 507 671 2.05 32.00 3.00 851 741 741 1412 3.02 33.00 4.00 33.30 4.30 Storage vs. Stage 3000 2500 y = 168.22xI 9239 W = 0.9992 2000 c U 1500 N 0 w 1000 - 500 0 0.00 1.00 2.00 3.00 4.00 5.00 Stage (feet) Ks = 168.2 b = 1.9239 Uecw HURS7 HAMILTON PARKING to STORM W ATER CONTROL MEASURE R. STUBBS, El UN W-17060 Volume Calculation 2/20/2018 (TOTAL VOLUME OF FACILITY Volume of Main Pool below Normal Pool= 178,984 cf Volume of Exiting Forebay below Normal Pool = 47,360 IT Volume of Proposed Forebay #1 below Normal Pool = 26,329 cf Volume of Pi oposed Forebay 42 below Normal Pool = 2,729 Total Volume of Forebays below Normal Pool= 76,418 cf Total Volume Below Normal Pool 255,402 cf Total Volume Above Normal Pool= 337,000 cf Total Volume of Facility = 592,401 Cf iFOREBAY PERCENTAGE OF PERMANENT POOL VOLUME —, Per NCDEQ Minimum Design Criteria, the forebay volume should equal opproxinialely 15.20% of the main pool volume. Iota] Main Pool Volume= 178,984 Cf Total Provided Forebay Volume= 76,418 cf Provided Existing Forebay Volume %= 265% Provided Proposed Forebays Volume%= 16.2% Total Provided Forebay Volume%= 42.7% tADDITIONAL FOREBAY VOLUME CALCULATIONS 20% of Main Pool Volume = 35,797 cf (forebay volume required per the NCDEQ Minimum Design Giteria) Total Drainage Area to the SCM = 1,218,903 sf Existing Forebay DA= 837,646 sf Existing Forebay DA/Tatal DA= 0.69 Forebay Volume Required for Proportion of DA= 24,500 cf Existing Foreboy Provided Volume= 47,360 cf Proposed Forebay 91 DA = 272,877 sf Proposed Forebay 01 DA/Total DA = 0.22 Forebay Volume Required for Proportion of DA= 8,014 cf Proposed Forebay#1 Provided Volume= 26,329 cf Proposed Forebay #2 DA = 51,947 sf Proposed Forebay #2 DA/Total DA= 0.04 Forebay Volume Required for Proportion of DA = 1,526 cf Proposed Foreboy 92 Proviced Volume = 2,729 rf 'AVERAGE DEPTH OF MAIN POOL Volume of Main Pool at Permanent Pool = 178,984 cf Surface Area of Main Pool at Permanent Pool = 31,275 if Average Depth= 5.72 ft FEB 2 2 '63 3 BY- UNCW HURST HAMILTON PARKING LOT STORMWATER CONTROL MEASURE UNW-17060 Surface Area Calculation R. STUBBS, El 2/9/2018 ,WET DETENTION BASIN SUMMARY Enter the drainage area characteristics =_> Total drainage area to pond = 27.98 acres Total impervious area to pond = 13.96 acres Note The basin must be sized to treat all impervious surface runoff draining into the pond, notjust the impervious surface from on -site development. Drainage area = 27.98 acres @ 49.9% impervious Estimate the surface area required at pond normal pool elevation ==> Wet Detention Basins are based on an minimum average depth of = 5.72 feet (Calculated) 5.0 5.72 6.0 Lower Boundary=> 40.0 1.83 1.39 Site % impervious => 49.9 2.35 1.97 1.83 Upper Boundary=> 50.0 2.35 1.83 Therefore, SA/DA required = 1.97 Surface area required for main pool at normal pool = 24,008 ft' = 0.55 acres Surface area provided for main pool at normal pool = 31,275 ft' Temporary Pool Elevation = 34.30 ft Temporary Pool Surface Area = 73,139 ft NCDEQ Stormwater BMP Manual Table 2: Coastal SA/DA Table (Adapted from Driscoll, 1986) 3 4 5- 6 7 8 10 0.78 0.61 0.44 0 0 0 20 1.48 1.04 0.87 0.7 0.52 0.35 30 2.18 1.65 1.39 1.13 0.87 0.7 ' 40 2.96 2.26 1.83 1.39 0.96 0.78. 50 3.65 2.87 2.35 1.83 1.31 1.96 60 4.35 3.31 2.78 2.26 1.74 1.13 70 5.22 3.92 3.22 2.52 i 1.83 1.31 80 5.92 4.52 3.65 2.78 1.91 1.57 90 6.53 5.05 4.18 2.96 2.44 1.74 100 7.13 5.92 4.87 3.83 2.78 1.83 UNCW HURST HAMILTON PARKING LOT STORMWATER CONTROL MEASURE R. STUBBS, El UN W-17060 WQV Calculation 2/9/2018 DETERMINATION OF WATER QUALITY VOLUME Proposed Development WQ v = (p)(R v)(A)/12 where, WQv=water quality volume (in acre-ft) Rv=0.05+0.009(I) where I is percent impervious cover A = area in acres P = rainfall (in inches) Input data: Total Drain Area, A = 812458 sf Total Drain Area, A = 18.65 acres Impervious area = 201844 sf Impervious area = 4.63 acres Percent impervious cover, I = 24.8 % Rainfall, P= 1.50 inches Calculated values: Rv= 0.27 WQv= 0.64 acre-ft = 27785 cf. Previously Permitted 1988-2008 WQ v = (P)(R v)(A)/12 where, WQv= water quality volume (in acre-ft) Rv= 0.05+0.009(I) where I is percent impervious cover A = area in acres P = rainfall (in inches) Input data: Total Drain Area, A = 352597 sf Total Drain Area, A= 8.09 acres Impervious area= 352597 sf Impervious area= 8.09 acres Percent impervious cover, I = 100.0 % Rainfall, P= 1.00 inches Calculated values: Rv= 0.95 WQv= 0.64 acre-ft 27914 cf. (SW8 0605301 UNCW HURST HAMILTON PARKING LOT STORMWATER CONTROL MEASURE R. STUBBS, El UN W-17060 WQV Calculation 2/9/2018 Previously Permitted 1008-2017 WQ v = (P)(R v)(A)/12 where, WQv= water quality volume (in acre-ft) Rv= 0.05+0.009(I) where I is percent impervious cover A = area in acres P = rainfall (in inches) Input data: Total Drain Area, A= 5952 sf Total Drain Area, A= 0.14 acres Impervious area= 5952 sf Impervious area= 0.14 acres Percent impervious cover, I = 100.0 % Rainfall, P= 1.50 inches Calculated values: Rv= 0.95 WQv= 0.02 acre-ft = 707 cf. Existing Impervious Not Previously Permitted Pre 1988 WQ v = (P)(R v)(A)112 where, WQv= water quality volume (in acre-ft) Rv= 0.05+0.009(I) where I is percent impervious cover A = area in acres P = rainfall (in inches) Input data: Total Drain Area, A= 14760 sf Total Drain Area, A = 0.34 acres Impervious area = 14760 sf Impervious area = 0.34 acres Percent impervious cover, I = 100.0 % Rainfall, P= 1.50 inches Calculated values: Rv= 0.95 WQv= 0.04 acre-ft = 1753 cf. /S W8 0605301 (SW80605301 UNCW HURST HAMILTON PARKING LOT STORMWATER CONTROL MEASURE U N W-17060 WQV Colculation R. STUBBS, El 2/9/2018 Other Permits 1988-1008 (1"Treated) WQ v = (P)(R v)(A)112 where, WQv= water quality volume (in acre-ft) Rv= 0.05+0.009(I) where I is percent impervious cover A = area in acres P = rainfall (in inches) Input data: Total Drain Area, A = 13154 sf Total Drain Area, A = 0.30 acres Impervious area = 13154 sf Impervious area = 0.30 acres Percent impervious cover, I = 100.0 % Rainfall, P= 1.00 inches Calculated values: Rv= 0.95 WQv= 0.02 acre-ft = 1041 cf. Other Permits 1008-1017 (1.5" Treated) WQ v = (P)(R v)(A)I12 where, WQv= water quality volume (in acre-ft) Rv= 0.05+0.009(I) where I is percent impervious cover A = area in acres P = rainfall (in inches) Input data: Total Drain Area, A = 10428 sf Total Drain Area, A = 0.24 acres Impervious area= 10428 sf Impervious area = 0.24 acres Percent impervious cover, I = 100.0 % Rainfall, P= 1.50 inches Calculated values: Rv= 0.95 WQv= 0.03 acre-ft = 1238 cf, (S W8 031039] (S W81004051 UNCW HURST HAMILTON PARKING LOT STORMWATER CONTROL MEASURE UN W-17060 WQV Calculation R. STUBBS, El 2/9/2018 Offsite (1.5" Treated) - includes ROW and Off-UNCW Property areas WQ v = (P)(R v)(A)/12 where, WQv= water quality volume (in acre-ft) Rv= 0.05+0.009(I) where I is percent impervious cover A = area in acres P = rainfall (in inches) Input data. - Total Drain Area, A = 9554 sf Total Drain Area, A = 0.22 acres Impervious area = 9554 sf Impervious area = 0.22 acres Percent impervious cover, I = 100.0 % Rainfall, P= 1.50 inches Calculated values: Rv= 0.95 WQv= 0.03 acre-ft = 1135 Cf. ASSOCIATED DEPTH IN POND WQv= 61573 cf. Stage / Storage Data: Ks = b = 64810 .232 1.232 Zo = 33.30 Total WQv= 61573 cf. Calculated values: Depth of WQv in Basin = 0.96 it = 11.51 inches Elevation = 34.26 ft UNCW HURST HAMILTON PARKING LOT STORMWATER CONTROL MEASURE UNW-17060 WQV Drawdown Calculation R. STUBBS, El 2/9/2018 DRAWDOWN WQ ORIFICE DESIGN D orifice= 4 inch p orifices = 1 Cd siphon= 0.60 Normal Pool Elevation = 33.30 feet Volume @ Normal Pool = 0 cf Orifice Invert= 33.30 feet WSEL at Water Quality Volume= 34.26 feet Water Quality Volume (Required Volume) = 61573 cf WSEL at Temp Pool (Provided) = 34.30 feet Orifice Equation: %ram NC DEQ Stormwoter Design Monual Calculations Document" Q= CDA(2"8*[Ho/3])0.5 Average driving head on orifice (Hd3) = 0.278 feet Orifice composite loss coefficient (Co) = 0.600 Cross -sectional area of siphon (A) = 0.087 sf Q= 0.2215 cfs Drawdown Time = Required Volume / Flowrate / 86400 (sec/day) Drawdown Time= 3.22 da s Hall, Christine From: Hall, Christine Sent: Friday, February 09, 2018 136 PM To: 'Perry, Daniel' Cc: Stubbs, Rebecca; Riggins, Daryl Subject: RE: lExternal] Hurst Hamilton Parking Lot (SW8 060S30) An extension until February 14' is fine with me. Thanks for the e-mail! Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources - State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct christine.hall@ncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 <> Nothing Compares - Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Perry, Daniel imailto:dperry@mcadamsco.com] Sent: Friday, February 09, 2018 1:28 PM To: Hall, Christine <Christine.Hall@ncdenr.gov> Cc: Stubbs, Rebecca <rstubbs@mcadamsco.com>; Riggins, Daryl <riggins@mcadamsco.com> Subject: RE: [External] Hurst Hamilton Parking Lot (SW8 060530) Christine, I would like to formally request an extension for the request for additional information for the Hurst Hamilton Parking Lot project (SW8 060S30). With limited resources available this past week, we need additional time to fully prepare the package for you. I would appreciate an extension to Wednesday, February 14`h. Thank you for your help with this. Thank you, Daniel Perry, PE I Project Manager, Water Resources McAdams 2905 Meridian Parkway, Durham, NC 27713 office 919. 361. 5000 x134 I direct 919. 287. 0795 1 mobile 919. 614.6212 1 dperry@mcadamsco.com www.mcadamsco.com I linkedin I twitter I instaeram I Join our team �JI MCA.DAMS creating experiences through experience From: Hall, Christine[mailto:Christine.Hall @ncdenr.eov] Sent: Friday, February 9, 2018 8:20 AM To: Perry, Daniel <dperry mcadamsco.com> Cc: Stubbs, Rebecca <rstubbs@mcadamsco.com> Subject: RE: [External] Hurst Hamilton Parking Lot (SW8 060530) Item l.b — I'm referring to the drainage area divide identified in-between those two arrows. Item 2.b —You are missing the point. The proposed forebays are oversized as well for their drainage areas. Forebays are required to be 15%to 20%of their contributing drainage area. If this can't be met, then justification for this variation must be provided. Item 3 — Please provide that calculation to demonstrate. Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct Christine. hall(a�ncdenr.gov 127 Cardinal Drive Ext. Wilmington, INC 28405 :'%'Nothing Cornpares Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Perry, Daniel [mailto:dperry@mcadamsco.com] Sent: Thursday, February 08, 2018 3:12 PM To: Hall, Christine <Christine.Hall@ncdenr.gov> Cc: Stubbs, Rebecca <rstubbs@mcadamsco.com> Subject: [External] Hurst Hamilton Parking Lot (SW8 060530) o External email:,Do. not click Links oropen attachments unlessverified. Send all suspicious emaiG.as an=attachment to" �; Re ort5 alnx •--ws`.Fl.. �, .J, u^.....= k n�.x r9 Christine, Good Afternoon! See below for questions and responses to your request for additional information. Please let me know your thoughts and we will get this one back to you for approval. Thanks for your help! 1. 15A NCAC 02H.1042(2)(g)(iv): Please provide additional proposed contours on sheets C10 and C11 to support the identified drainage areas and patterns in the following areas: a. The intersection of Hurst Drive and Hamilton Drive. McAdams Response: Contour labels have been added to clarify the drainage area in this location b. The sidewalk high point off McMillan Ave near the pump station. McAdams Response: Which location are you referring to? There is a slope call out that shows the drainage directed away from the road, as requested during the express review. Or 3 EX FIBER OP'n CABI.,E (TYP.) Ci ti / ��j:�i�•. i. •rY:S''I !. tom, a.�'j�.���tS 1i...yak:� \ y:ti,SJr''•.;xy;,!ii^ `tii:i; :r jai•!. j C`j� �:r: r r li ��:.: ii•'r•f i �r + I ' jfjj � � _ `✓T .� ii:.; � (t+" / ry'(:`;, ..v�%i: ih'� t:cr �,?ti. + ..v�:S�i°,•a'l,+r;.T,',.., q..i}:• t :+:i:;),.a-f�i- ` ''��� i � ��./� �i`.j•LT:•.trriL.::(. .1(... . rti iY S3.l..: .iy..:'aia I '�� II: �— — !p\�^�:'•.�•'ii)::<raj:.<!i �_, ..�::��^,�.tY.-i:.Iti.. �=t=:7: "r'�'� r ►����� ij111 -;i1l, HrJI : jt� Portions of this side walk that can't be drained to the parking lot will sheet flow into the SCM. c. The west parking lot access drive on McMillian Ave. McAdams Response: The drainage area will be adjusted to move the high point to the blue line represented below. All calculations will be adjusted accordingly. N 2. 15A NCAC 02H.1053(5):. a. The sum of the forebay drainage areas presented in the calculations is less than the total drainage area to the pond. Please explain the difference. McAdams Response: There are some areas within the overall drainage area to the SCM that overland flow into the Main Pool. The size of these areas has been reduced from the existing condition in the proposed 9 layout, as all concentrated discharges resulting from the proposed development are directed into one of the forebays to receive pretreatment prior to entering the main pool portion of the SCM. b. In reviewing the calculations for sizing the individual forebay volumes, it appears that each of the three forebays (existing and proposed) exceed 20% of its area weighted volume in the main pool. 15A NCAC 02H.1053(5)(a) requires the forebay volume to be 15 to 20% of the volume in the main pool. Please either reconsider the size of the three forebays or provide justification for the variations in accordance with 15A NCAC 02H.1003(6) McAdams Response: Language has been added to the narrative to discuss the matter. The forebay volume provided in the SCM is in excess of the 15-20% required volume. This is in large part due to the contribution of volume of the existing forebay, in addition to providing forebays for each of the proposed concentrated discharges into the SCM. While the total forebay volume exceeds the MDC requirement, the main pool remains significantly oversized per the surface area calculation using the SA/DA method. Therefore, this SCM is providing better treatment than the minimum requirement stated in 15A NCAC 02H .1053(5)(a). 3. 15A NCAC 02H.1003(1)(b): In Attachment A, the existing, pre-1988 built upon area is not included in the total BUA for the site. Please demonstrate that the project area used for this drainage area meets either 15A NCAC 02H.1003(1)(a) or .1003(1)(b). McAdams Response: The project area was determined using the method described in 15A NCAC 02H .1003 (1)(b). The existing, pre-1988 BUA in the low density portion of this permit was subtracted from the total BUA and the total project area within that drainage area to determine project density. Daniel Perry, PE I Project Manager, Water Resources McAdams 2905 Meridian Parkway, Durham, NC 27713 office 919. 361. 5000 x134 ) direct 919. 287. 0795 1 mobile 919. 614.6212 ( dperry@mcadamsco.com www.mcadamsco.com I linkedin I twitter I instagram (loin our team 1111 MCADAMS creating experiences through experience Energy. Mineral & Land Resources ENVIRONMENTAL QUALITY ROY COOPER Governor MICHAEL S. REGAN Secretary WILLIAM E. (TOBY) VINSON, JR. Interim Director Pebruary 2, 2018 a�ah t� UNC Wilmington Attn: Vice Chancellor for Business Affairs c/o Mark Morgan. Associate Vice Chancellor for Business Affairs -Facilities 601 S. College Rd. Wilmington, NC 28403 Subject: Bequest for Additional Information Stormwater Project No. SV1'8 060530 Hurst Iamilton parking Lots New Hanover County Dear Mr. Morgan: 'fire Wilmington Regional Office received and accepted a modified Express State Stormwater Management Permit Application for the subject project on January 16, 2018 with additional information received on January 29, 2018. A preliminary in-depth review of that information has determined that the application is not complete and that additional information is needed. To continue the review, please provide the following additional information: ✓l. 15A NCAC 021-I.1042(2)(g)(iv): Please provide additional proposed contours on sheets CIO and Cl 1 to support the identified drainage areas and patterns in the following areas: ol, a. The intersection of Hurst Drive and Hamilton Drive ,b� The sidewalk high point off McMillan Ave near the pump station. L—c' The west parking lot access drive on McMillian Ave. Recommendation: 117 the case where the contour interval on a "topographic" map is too large to adequately reflect the existing and proposed drainage patterns of a relatively flan property, spot elevations and/or a sire -specific elevation survey may he needed. 2. 15A NCAC 02I-1.1053(5): , . The sum of the forebay drainage areas presented in the calculations is less than the total drainage area to the pond. Please explain the difference. b. In reviewing the calculations for sizing the individual forebay volumes, it appears that each of the three forebays (existing and proposed) exceed 20% of its area weighted volume in the main pool. 15A NCAC 021-I.1053(5)(a) requires the forebay volume to be 15 to 20% of the volume in the main pool. Please either reconsider the sire of the three forebays or provide justification for the variations in accordance with 15A NCAC 02I-1.1003(6). Z3. 15A NCAC 021-I.1003(I)(b): In Attachment A, the existing, pre-1988 built -upon area is not included in the total BUA for the site. Please demonstrate that the project area used for this drainage area meets either 15A NCAC 021-I.1003(1)(a) or .1003(1)(b). 4. Due to the relatively minor nature of these comments, the express additional information review fee has been waived. Please remember to confirm that any revised information is presented consistently throughout the application documents including calculations, supplements, narrative, and plans. Please also remember to provide two hard copies of any updated documents per 15A NCAC 02I-1.1042(2). 51ateof North Carolina I Enviionmental Qualify I Energy. Mineral and Land Resources Wilmington Regional Office 1127 Cardinal Drive Extension I Wilmington, NC 28405 010 796 7215 State Stormwater Permit No. SW8 0605-,0 Page 2 of 2 The requested information should be received in this Office prior to February 12, 21118, or the application will be returned as incomplete. Please note that only livo letters reguesling additional information is allowed in the State Stormwater Program. If the information is not satisfactorily provided after the second regUest, the project will be returned. If the project is returned and you wish to re -submit to the Lxpress Program, you will need to reschedule the project through the Lxpress Coordinator for the next available review date and will need to resubmit all required items at that time, including the application fee. If additional time is needed to submit the requested infornunion, please email your extension request, prior to the original due data to the Division at the email address provided below. The extension request must include a justification and a date of when the requested information will be submitted to the Division, which shall be no later than 5 business days past the original due date. Please remember that extension requests delay the issuance of the final permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to \CGS 143-215.6A. Please label all packages and cover letters as "Express" and reference the State assigned project number on all correspondence. If you have any questions concerning this matter, please feel free to call me at (910) 796-7215 or email me at cliritsinc.11;ill@ilcdeiir.gov. ncdenr.gov. Sincerely, Christine Hall larvironmental Engineer GDS/cash: %Stormwater-Termits & Projects\2006\060530 I lD\2018 02 addinfo 060530 cc: Galen Jamison, PE, Project Manager, UACW Daryl Riggings, PE; McAdams Wilmington Regional Office Stormwater Pile State of North Carolina I GnviromnentaI Quality I Energy, Mineral and Land Resources Wilmington Regional Office 1127 Cardinal Drive Extension I Wilmington, NC 28405 910 796 7215 Hall, Christine From: Hall, Christine Sent: Friday, February 02, 2018 3:28 PM To: 'Riggins, Daryl'; 'jamisong@uncw.edu' Cc: Weaver, Cameron Subject: RE: 2nd request for additional info- Hurst Hamilton Parking Lots, SW8 060530 Sorry Galen, I had a typo in your e-mail. Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct christine.hali@ncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 `Nothing Compares.. Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Hall, Christine Sent: Friday, February 02, 2018 3:25 PM To:'Riggins, Daryl' <riggins@mcadamsco.com>; Galin Jamison (jaimsong@uncw.edu) <jaimsong@uncw.edu> Cc: Weaver, Cameron <cameron.weaver@ncdenr.gov> Subject: 2nd request for additional info- Hurst Hamilton Parking Lots, SW8 060530 Daryl, I have had a chance to review the revised items and there are just a few minor details that need to be addressed. A pdf of the second request for additional information is attached. Please let me know if you have any questions. Christine Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct christine. haII(cDncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 Kra ` ,Nothing Compares. Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Riggins, Daryl [maiIto: riggins@mcadamsco.com] ^ Sent: Friday, January 19, 2018 2:08 PM To: Hall, Christine <Christine.Hall@ncdenr.gov>; Galin Jamison (jaimsong(@uncw.edu) <jaimsong@uncw.edu> Cc: Weaver, Cameron <cameron.weaver@ncdenr.gov> Subject: [External] RE: request for additional info- Hurst Hamilton Parking Lots, SW8 060530 CAUTION: External email. Do not click links or open attachments unless verified. Send all suspicious email as an attachment to report.spam@nc.gov. Christine, We're reviewing the comments and requests for information at this time. Thanks, Daryl Riggins, PE i Project Manager, Institutional McAdams 2905 Meridian Parkway, Durham, NC 27713 office 919. 361. 5000 i direct 919. 287. 0872 i mobile 919. 357. 0445 i riggins@mcadamsco.com www.mcadamsco.com i linkedin i twitter ] instagram i loin our team !!J1 MCADAMS creating experiences through experience From: Hall, Christine[maiIto:Christine.Hall@ncdenr.gov] Sent: Friday, January 19, 2018 1:55 PM To: Galin Jamison (jaimsong@uncw.edu) <iaimsong@uncw.edu>; Riggins, Daryl <riggins@mcadamsco.com> Cc: Weaver, Cameron <cameron.weaver@ncdenr.gov> Subject: request for additional info- Hurst Hamilton Parking Lots, SW8 060530 Gentlemen, Attached is a pelf of the request for additional information for the modification to SW8 060530 to add the Hurst and Hamilton Parking Lots. Please let me know of any questions or concerns. Christine Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct christine. hall@ncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 3y. -;"i Nothing Compares, >f Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. 'JI MCADAMs Date: January 26, 2018 To: Ms. Christine Hall Division of Energy, Mineral and Land Resources State Stormwater Program Department of Environmental Quality 127 Cardinal Drive Ext. Wilmington, North Carolina 28405 I am sending you the following items: ❑ Drawings ❑ Letter ❑ Specifications ® Submittal ❑ Plans ❑ Prints LETTER OF TRANSMITTAL FEDERAL EXPRESS Re: University of North Carolina - Wilmington Hurst Hamilton Parking Lots Stormwater Management Plan Job#t: UNW-17060 ❑ Statement of Qualifications ❑ Other QUANTITY UNIT DESCRIPTION 1 Copy Stormwater Impact Analysis 1 Check Express Re -Review Fee $500.00 1 Set SCM O&M Form 1 Set SCM Supplement Form 1 Set I Stormwater Permit Application 1 Original & 1 Copy 2 Sets Construction Drawings 1 Copy Response to Comments'letter Transmitted as checked below: ® Forapproval ❑ For your use ❑ As requested Remarks: Copy to: ❑ For review + comment ❑ Other ❑ Other r Signature: Dart Project Manager, Water Resources creating experiences through experience 2905 Meridian Parkway, Durham, NC 277131919. 361. 5000 'J MCADAMS January 26, 2018 State of North Carolina Environmental Quality, Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 RE: Hurst Hamilton Parking Lots Response to Preliminary NCDEQ Comments McAdams Project: UNW-17060 RESPONSE TO COMMENTS > UNW-17060 OEIIVE JAM 2 9 2018 The following are the response comments for the above -mentioned project. Our response comments are in bold. NCDEQ: Christine Hall, Environmental Engineer, 910. 796. 7215 1. 15A NCAC 02H.1042(2)(a)(iv) and .1042(2)(f): Please confirm the following project information: a. In Attachment A, please provide a project area associated with the redevelopment exemption column. McAdams Response: The project area of the redevelopment exemption has been provided in Attachment A. It was assumed that the project area is equal to the impervious area that is considered the redevelopment exemption. b. The redevelopment exemption column in Attachment A should only include the proposed amount of built - upon area (BUA), not the existing too. Please remove the 14,760 sf from that column. McAdams Response: The redevelopment exemption column now only includes the proposed BUA. c. The total column in Attachment A does not include the redevelopment exemption column. Please include all areas covered under this permit. McAdams Response: The total column of Attachment A has been revised to include all areas covered under the permit. In the impervious surface area section of Attachment A, please clarify the three labels directly beneath SW8 100405 by providing a more descriptive label. The references are confusing and doesn't help to identify the source of the BUA. McAdams Response: A relative location has been added to the description of the categories of impervious surface in Attachment A mentioned above. creating experiences through experience 2905 Meridian Parkway, Durham, NC 27713 / 919. 361. 5000 M WADAMS RESPONSE TO COMMENTS > UNW-17060 e. This system was previously approved to allow 6,000 square feet of offsite runoff to be treated at the 1" design storm. Any additional offsite area captured due to the expanding drainage area must be treated at the current design storm. Please reconsider the minimum required volume for this offsite area. McAdams Response: All offsite areas draining to the SCM have been revised to be treated to the current design storm (1.5"). Pleaser refer to the WQ Volume calculations in Section 6 of this report. The sum of the drainage areas presented in the calculations to determinate the water quality volume appears to be 14,760 square feet in excess of the drainage area presented in the other application documents. Additionally, the total wet pond drainage area presented in the wet pond supplement is not consistent with the total drainage area presented in Attachment A. Please confirm the drainage area to the pond. McAdams Response: The drainage area to the pond has been revised to be consistent across all reporting forms. The total drainage area in the WQ volume calculations has been corrected. 2. 15A NCAC 02H.1042(2)(g)(iii): Please provide the boundaries of all surface waters, wetlands, regulatory flood zones, protected vegetated setbacks, and protected riparian buffers, or a note on the plans that none exist. If this note is already on the plans, please provide a citation to find it. McAdams Response: A note has been added to the Existing Conditions survey (sheet C-1). 3. 15A NCAC 02H.1042(2)(g)(iv): Please provide additional proposed contours to support the identified drainage areas and patterns. Recommendation: In the case where the contour interval on a "topographic" map is too large to adequately reflect the existing and proposed drainage patterns of a relatively flat property, spot elevations and/or a site -specific elevation survey may be needed. McAdams Response: Please cross reference sheets C-10 and C-11 for detailed spot shots to support the drainage areas delineated on the drainage area and BUA map. The scale of the DA and BUA map does not allow for clarity in adding spot shots. 4. 15A NCAC 02H.1042(2)(g)(iv) and (vii): Two vegetated islands along Hamilton Drive use concrete flumes to direct runoff, however, these islands and the concrete flumes are not included in the drainage area. Please confirm that the delineated drainage area considers all stormwater collection features proposed. McAdams Response: The drainage area to the pond has been revised to accurately reflect the drainage patterns within each of the parking lots. 5. 15A NCAC 02H.1042(2)(h): Sheet SW-2 includes cross section views of the various pond features except forebay #2. Please provide a cross-section view of forebay #2. McAdams Response: A cross-section view of Proposed Forebay #2 has been added to sheet SW-2. 6. 15A NCAC 02H.1050(4): Please provide details on the outlet protection proposed for EW-300 on sheet C-11. McAdams Response: A callout with sizing dimensions has been provided on sheet C-11. creating experiences through experience 2 of 5 u 'J MCADAMS RESPONSE TO COMMENTS > UNW-17060 15A NCAC 02H.1050(12): The provided operation and maintenance agreement does not include the information for the existing forebay. Please include the existing forebay in the operation and maintenance agreement. McAdams Response: The existing forebay information from the previously approved O&M has been added to the Operation and Maintenance Manual. 8. 15A NCAC 02H.1053(1) and (2): The main permanent pool volume and average depth presented in the supplement is not consistent with the values listed in the calculations. Please confirm. McAdams Response: The supplement has been revised to be consistent with the SCM calculations provided in Section 6 of this report. 15A NCAC 02H.1053(5): a. The narrative notes that the exiting forebay will remain unaltered. However, the design and calculations are not consistent with the originally approved forebay design. This forebay was approved during a time when the entire forebay, including the sediment storage, was used to determine the volume available in the forebay. The calculations provided in 2006 indicate that the volume of this forebay was determined using the following equation: (18,775 + 5,610) / 2 * 5 ft = 60,962 ft3. The submitted stage -storage calculations for this existing forebay do not consider the full 5-foot depth If it is desired to maintain the original design, then please re -consider the stage storage table to include the same characteristics as originally permitted. However, if it is desired to permit this forebay under the 2017 requirements, then please either ensure the forebay meets the requirements of 15A NCAC 02H.1053 or, if not all of the requirements can be met, provide justification for the variations per 15A NCAC 02H.1003(6). Depending on the elevation of the pipes connecting the existing forebay to forebay #1, another option under the 2017 rules might be to consider these two as a single, hydrologically connected forebay. McAdams Response: The narrative has been revised to state that a stage storage function was generated for the existing forebay using survey of current conditions provided by Avioimage. b. The accumulated volumes listed in the stage storage table for Forebay #2 are not consistent with the incremental volumes. Please confirm the calculation for the accumulated volume. McAdams Response: The calculation of the accumulated volumes has been corrected. c. Please provide calculations demonstrating that the forebays have been sized to handle 15%to 20% of their respective contributing drainage areas. McAdams Response: See revised calculations regarding the provided forebay volume. The total forebay volume provided exceeds the requirement per the MDCs. To ensure that each forebay was creating experiences through experience 3 of 11111 = McADAMS RESPONSE TO COMMENTS > UNW-17060 proportionally sized to handle its respective drainage area, the required forebay volume (20% of the main pool volume) was determined and then proportionally split between the forebays based on their drainage areas. For each forebay, the volume provided exceeds this calculated minimum. d. The forebay volume listed in the supplement is not consistent with the forebay volumes listed in the calculations. Please confirm. McAdams Response: The forebay volume has been corrected to be consistent on all forms. The supplement lists the depth of the forebay at the entrance and exit as being 87.6 inches or 7.3 ft and the cleanout depth as 82 inches or 6.8 ft. However, none of the proposed forebays appear to be that deep. Also, the MDC requires the entrance to be deeper than the exit. Please confirm the forebay design meets the requirements of 15A NCAC 02H.1053(5)(b) and that the information is presented consistently and accurately. McAdams Response: The supplement form has been revised to more clearly show the entrance and exit depths for each of the forebays. 10. 15A NCAC 02H.1053(6): The supplement lists the top of the vegetated shelf as being set at an elevation of 34.3 ft but Sheet SW-1 and SW-3 lists the top as 34.5 ft. Please confirm the top elevation of the vegetated shelf. McAdams Response: The callouts on SW-1 and SW-3 have been corrected to reflect 34.30 as the top of shelf elevation. 11. 15A NCAC 02H.1053(7) and .1002(10): a. The supplement, calculations, and other application documents indicate that the temporary pool elevation is set at 34.27 ft; however, the outlet structure detail on plan sheet SW-2 indicates that the next available outlet is set at 34.30 ft. The design volume of a wet pond is contained between the permanent pool elevation and the elevation of the next available outlet. This next available outlet is considered to be the temporary pool elevation. Please reconsider the elevation of the temporary pool and ensure it is presented consistently. McAdams Response: The temporary pool elevation has been updated in the calculation book and the construction drawings to be 34.30, the invert of the next overflow orifice. b. The supplement identifies the design volume as being 64,910 cf, however, calculations could not be found to support that volume. The stage -storage table demonstrates that the volume stored at an elevation of 34.3 ft is 66,951 cf. Once the temporary storage elevation is confirmed, please ensure to provide calculations to support the volume stored at that elevation. McAdams Response: The design volume has been revised in the calculations to reflect the storage volume in the pond at the temporary pool elevation (34.30). creating experiences through experience 4 of 5 iJ MCADAMS RESPONSE TO COMMENTS > UNW-17060 c. The drawdown chart starts at an elevation of 34.3 ft however the identified volume stored at this elevation, 64,810 cf, is not consistent with the storage volume presented at this elevation in the stage - storage table for above the normal pool. Please confirm the drawdown calculations are based on the provided pond design. McAdams Response: The drawdown calculations have been simplified for more clarity. 12. N.C.G.S. 143-214(c3): If the project is within 5 statute miles of a public airport, the Division cannot require the use of a BMP with a permanent pool of water. A copy of the permit will be forwarded to the airport's director who may elect to adjudicate the permit if the applicant has chosen to use a BMP with a permanent pool of water. McAdams Response: Noted. 13. Due to the insufficiency of the application, please submit a $500 fee for the additional review required for this application (in accordance with Session Law 2003-284, Section 11.4A(b)). McAdams Response: A check for the additional review fee has been provided. Consideration of this response is greatly appreciated. If you should have any questions or require additional information, please do not hesitate to contact me at 919. 361. 5000. Sincerely, MCADAMS Daniel Per , Project Manager, Water Resources DP/hc creating experiences through experience 5 of 5 Energy. Mineral & Land Resources ENVIRONMENTAL QUALITY January 19, 2018+� UNC Wilmington 2�a\ Attn: Vice Chancellor for Business Affairs c/o Mark Morgan, Associate Vice Chancellor for Business Affairs -Facilities 601 S. College Rd. Wilmington, NC 28403 Subject: Request for Additional Information Stormwater Project No. SWS 060530 Ilurst Hamilton Parking Lots New Hanover County Dear Mr. Morgan: ROY COOPER Governor MICHAEL S. REGAN Secretary TRACY DAVIS Director \ W\2i The Wilmington Regional Office received and accepted a modified Express State Stormwater Management Permit Application for the subject project on January 16, 2018. A preliminary in-depth review of that information has determined that the application is not complete and that additional information is needed. To continue the review, please provide the following additional information: 1. 15A NCAC 021-I.1042(2)(a)(iv) and .1042(2)(0: Please confirm the following project information: In Attachment A, please provide a project area associated with the redevelopment ! exemption column. ✓b. The redevelopment exemption column in Attachment A should only include the proposed amount of built -upon area (13UA), not the existing too. Please remove the 14,760 sf from that column. ,,,'c. The total column in Attachment A does not include the redevelopment exemption column. Please include all areas covered under this permit. I/d. In the impervious surface area section of Attachment A, please clarify the three labels directly beneath SW8 100405 by providing a more descriptive label. The references are confusing and doesn't help to identify the source of the BUA. ✓c. "I'his system was previously approved to allow 6,000 square feel of offsite runoff to be treated at the 1" design storm. Any additional offsite area captured due to the expanding drainage area must be treated at the current design storm. Please reconsider the / minimum required volume for this offsite area. `/f. The sum of the drainage areas presented in the calculations to determinate the water quality volume appears to be 14,760 square feet in excess of the drainage area presented in the other application documents. Additionally, the total wet pond drainage area presented in the wet pond supplement is not consistent with the total drainage area presented in Attachment A. Please confirm the drainage area to the pond. /. 15A NCAC 021-I.1042(2)(g)(iii): Please provide the boundaries of all surface waters, wetlands, regulatory flood zones, protected vegetated setbacks, and protected riparian buffers, or a note on the plans that none exist. If this note is already on the plans, please provide a citation to find it. I tiA u"LeAra^ 3. 15A NCAC 021-1.1042(2)(g)(iv): please provide additional proposed contours to support the identified drainage areas and patterns. Recommendation. In the case where the contour interval on a "topographic" map is too large to adequately reflect the existing and proposed drainage AE�:�atternS of a relatively flat property, spot elevations and/or a site -specific elevation survey may vo s, \tin. ?,v be needed. 'ica\o.. G...morn :\\c-• State of North Carolina I Environmental Quality I Energy, Mineral and Land Resources Wilmington Regional office 1127 Cardinal Drive Extension I Wilmington, NC 28405 910 796 7215 State Stormwater Permit No. SW8 060530 Page 2 of 3 t/4. 15A NCAC 0211.1042(2)(g)(iv) and (vii): Two vegetated islands along Hamilton Drive use concrete flumes to direct runoff; however, these islands and the concrete flumes are not included in the drainage area. Please confirm that the delineated drainage area considers all stormwater collection features proposed. _,,5� 15A NCAC 021-1.1042(2)(h): Sheet S\N-2 includes cross section views of the various pond features except forebay H2. Please provide a cross-section view of forebay 412. �/O. 15A NCAC 021-1.1050(4): Please provide details on the outlet protection proposed for GW-300 on sheet C-1 I. J7. 15A NCAC 0211.1050(12): -fhe provided operation and maintenance agreement does not include the information for the existing forebay. Please include the existing forebay in the operation and maintenance agreement. /8. 15A NCAC 021-1.1053(1) and (2): The main permanent pool volume and average depth presented in the supplement is not consistent with the values listed in the calculations. Please confirm. 9. 15A NCAC 021-1.1053(5): 'fhe narrative notes that the exiting forebay will remain unaltered. However, the design and calculations are not consistent with the originally approved forebay design. -]'his forebay was approved during a time when the entire forebay, including the sediment storage, was used to determine the volume available in the forebay. The calculations provided in 2006 indicate that the volume of this forebay was determined using the following equation: (18,775 + 5,610) / 2 * 5 ft= 60,962 ft'. The submitted stage -storage calculations for this existing forebay do not consider the full 5-foot depth If it is desired to maintain the original design, then please re -consider the stage storage table to include the same characteristics as originally permitted. however, if it is desired to permit this forebay under the 2017 requirements, then please either ensure the forebay meets the requirements of 15A NCAC 0211.1053 or, if not all of the requirements can be met, provide justification for the variations per 15A NCAC 021-1.1003(6). Depending on the elevation of the pipes connecting the existing forebay to forebay Nl, another option under the 2017 rules might be to consider these two as a // single, hydrologically connected forebay. I/o. The accumulated volumes listed in the stage storage table for Porebay 42 are not consistent with the incremental volumes. Please confirm the calculation for the accumulated volume. 7 c. Please provide calculations demonstrating that the forebays have been sired to handle / 15% to 20% of their respective contributing drainage areas. ✓d. The forebay volume listed in the supplement is not consistent with the forebay volumes listed in the calculations. Please confirm. The supplement lists the depth of the forebay at the entrance and exit as being 87.6 inches or 7.3 ft and the cleanout depth as 82 inches or 6.8 ft. I lowever, none of the proposed forebays appear to be that deep. Also, the MDC requires the entrance to be deeper than the exit. Please confirm the forebay design meets the requirements of 15A NCAC 021-1.1053(5)(b) and that the information is presented consistently and accurately. 10. 15A NCAC 0211.1053(6): The supplement lists the top of the vegetated shelf as being set at an elevation of 34.3 ft but Sheet SW-1 and SW-3 lists the top as 34.5 ft. Please confirm the top elevation of the vegetated shelf. 11. 15A NCAC 021-1.1053(7) and .1002(10): ✓a. The supplement, calculations, and other application documents indicate that the temporary pool elevation is set at 34.27 ft; however, the outlet structure detail on plan Sheet SW-2 indicates that the next available outlet is set at 34.30 ft. The design volume of a wet pond is contained between the permanent pool elevation and the elevation of the next available outlet. This next available outlet is considered to be the temporary pool elevation. Please reconsider the elevation of the temporary pool and ensure it is presented consistently. State of North Carolina I Environmental Quality I Energy. Mineral and Land Resources Wilmington Regional Office 1127 Cardinal Drive Extension I Wilmington, NC 28405 910 796 7215 State Stormwater Permit No. S\v8 060530 Page 3 of 3 b. The supplement identifies the design volume as being 64,910 cf; however, calculations could not be found to support that volume. The stage -storage table demonstrates that the volume stored at an elevation of 34.3 fi is 66,951 cf'. Once the temporary storage elevation is confirmed, please ensure to provide calculations to support the volume stored at that elevation. f. The drawdown chart starts at an elevation of 34.3 Ft however the identified volume stored at this elevation, 64,810 cf, is not consistent with the storage volume presented at this elevation in the stage -storage table for above the normal pool. Please confirm the drawdown calculations are based on the provided pond design. o�c­ 12. N.C.G.S. 143-214(c3): If the project is within 5 statute miles of a public airport, the Division cannot require the use of a 13NIP with a permanent pool of water. A copy of the permit will be forwarded to the airport's director who may elect to adjudicate the permit if the applicant has chosen to use a 13MP with a permanent pool of water. ✓13. Due to the insufficiency of the application, please submit a S500 fee for the additional review required for this application (in accordance with Session Law 2003-284, Section 1 1.4A(b)). Please remember to confirm that any revised information is presented consistently throughout the application documents including calculations, supplements, narrative, and plans. Please also remember to provide two hard copies of any updated documents per 15A NCAC 02I-1.1042(2). The requested information should be received in this Office prior to January 29, 2017, or the application will be returned as incomplete. If the project is returned and you wish to re -submit to the Express Program, you will need to reschedule the project through the Express Coordinator for the next available review date and will need to resubmit all required items at that time, including the application fee. If additional time is needed to submit the requested information, please email your extension request, prior to the original due dale, to the Division at the email address provided below. The extension request must include a justification and a date of when the requested information will be submitted to the Division, which shall be no later than 5 business days past the original due date. Please remember that extension requests delay the issuance of the final permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation ofNCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. Please label all packages and cover letters as "Express" and reference the State assigned project number on all correspondence. If you have any questions concerning this matter, please feel free to call me at (910) 796-7215 or email me at chritsine.hall@ncdenr.gov. Sincerely, �j_k Christine Hall Environmental Engineer GDS/canh: \\\Stormwater\Permits & Projects\2006\060530 HD\2018 01 addinfo 060530 cc: Galen Jamison, PI:, Project Manager; UNCW Daryl Riggings, PF" McAdams Wilmington Regional Office Stormwater Pile State of Nonh Carolina I Environmental Quality I Energy. Mineral and Land Resources Wilmington Regional Office 1127 Cardinal Drtve Extension I Wilmington, NC 28405 910 796 7215 Hall, Christine From: Hall, Christine Sent: Friday, January 19, 2018 1,55 PM To: Galin Jamison Oaimsong@uncw.edu), Riggins, Daryl Cc: Weaver, Cameron Subject: request for additional info- Hurst Hamilton Parking Lots, SW8 060530 Attachments: 2018 01 addinfo 060530.pdf Gentlemen, Attached is a pdf of the request for additional information for the modification to SW8 060530 to add the Hurst and Hamilton Parking Lots. Please let me know of any questions or concerns. Christine Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources - State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct christine.hall@ncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 Nothing Compares.. - Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. IJ MCADAMS Date: January 15, 2018 To: Ms. Christine Hall Division of Energy, Mineral and Land Resources State Stormwater Program Department of Environmental Quality 127 Cardinal Drive Ext. Wilmington, North Carolina 28405 I am sending you the following items: ❑ Drawings ❑ Letter ❑ Specifications ® Submittal ❑ Plans ❑ Prints LETTER OF TRANSMITTAL FEDERAL EXPRESS Re: University of North Carolina- Wilmington Hurst Hamilton Parking Lots Stormwater Management Plan Job #: UNW-17060 ❑ Statement of Qualifications ❑ Other QUANTITY UNIT DESCRIPTION 1 Copy Stormwater Impact Analysis 1 Check Express Review Fee $4,000 1 Set SCM O&M 1 Original & 1 Copy 1 Set SCM Supplement Form 1 Original & 1 Copy 1 Set Stormwater Permit Application 1 Original & 1 Copy 2 Sets Construction Drawings 1 CD Digital Copy Tn be T/hsc/ a m4441 Transmitted as checked below: ® Forapproval ❑ Foryouruse ❑ As requested Remarks: Copy to: ❑ For review + comment ❑ Other ❑ Other GE Signature: 1� Daniel Perry, PE Project Manager, Water Resources creating experiences through experience 2905 Meridian Parkway, Durham, NC 27713 / 919. 361. 5000 Hefl, Christine From: Hall, Christine Sent: Wednesday, November 29, 2017 2:13 PM To: 'Perry, Daniel' Cc: Riggins, Daryl Subject: RE: [External] UNCW Hamilton -Hurst Parking Lot Construction Access Since a pipe is proposed to be installed 1 foot off the bottom, I don't have a problem with that during construction. But you may want to check with EC to see if they have any comments. Christine Hall Environmental Engineer Division of Energy, Mineral and Land Resources — State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7335 direct christine.hall@ncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 - '>,Nothing Compares Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Perry, Daniel [mailto:dperry@mcadamsco.com] Sent: Tuesday, November 28, 2017 1:18 PM To: Hall, Christine <Christine.Hall@ncdenr.gov> Cc: Riggins, Daryl <riggins@mcadamsco.com> Subject: [External] UNCW Hamilton -Hurst Parking Lot Construction Access ICAUTION: External email. Do not click links or open attachments unless verified. Send all suspicious email as an attachment to Ireport.spam@nc.Rov. Christine, I hope you had a great thanksgiving. We are looking into an alternate construction access path for the west lot instead of using MacMillan Ave. Please see the below image which shows our use of a proposed forebay berm to provide access during the construction phase of the project from the east lot. Since we are already regrading the facility to meet current MDC rules, it is our hope that this path will be acceptable during construction. Please let me know of any concerns or rules preventing this. I'm happy to discuss via phone if that works best. Thanks for your help, Daniel Perry, PE I Project Manager, Water Resources McAdams 2905 Meridian Parkway, Durham, NC 27713 office 919. 361. 5000 x134 I direct 919. 287. 0795 1 mobile 919. 614.6212 1 dperrv@mcadamsco.com www,mcadamsco.com I linkedin I twitter I instazram I join our team 2 MCADAMs creating experiences through experience 2 For DE0 Use ONLY W Reviewer. North Carolina Department of Environmental Quality $emsit Request for Express Permit Review Tme'. coofem: _✓ FILL-IN all the information below and CHECK the Permit(s) you are requesting for express review. Call and Email the completed form to the Permit Coordinator along with a completed DETAILED narrative, site plan (PDF file) and vicinity map (same items expected in the application package of the project location. Please include this form in the application package. • Asheville Region -Alison Davidson 828-296.4698;alison.davidson(a)ncdenr.gov • Fayetteville or Raleigh Region -David Lee 919-791-4203; david.lee(aMcdenr.gov • Mooresville or Winston Salem -Marcia Allocco 704-235-2107; marcia.allocco(a)ncdenrgov • Washington Region -Lyn Hardison 252-948-3842 or Ivn.hardison@)ncdenr.gov • Wilmington Region -Cameron Weaver910-796-7303 orcameron.weaver(cimcdenri NOTE: Project application received after 12 noon will be stamped in the following work day. Project Name: HURST HAMILTON PARKING LOTS County: NEW HANOVER Applicant: GALEN JAMISON Company: UNCW Address: 601 S COLLEGE ROAD City: WILMINGTON, Slate: NC Zip: 28403 Phone: 910-962-2677. Fax: _ _ Email: jam1 isong@uncw.edu Physical Location INTERSECTION OF HAMILTON & HURST related to this Project SW 8060530 SW_ SW _ NPDES _ NPDES _ WO _ WO _ E&S _ E&S _ Other Project Drains into BURNT MILL CREEK waters — Water classification C:SW (DWR Surface Water Classifications Map) Project Located in CAPE FEAR River Basin. Is project draining to class ORW waters? NO. within X,, mile and draining to class SA waters NO or within 1 mile and draining to class HOW waters? NO Engineer/Consultant: DARYL RIGGINSCompany: MCADAMS Address: 2905 MERIDIAN PARKWAY City: DURHAM, State: NC Zip: 27713- Phone: 919-361-5000, Fax: 910-361-2269, Email: finch@mcadamsco.com PLEASE PROVIDE ESTIMATED INVESTMENT AND EXPECTED EMPLOYMENT, IF AVAILABLE S_ #_JOBS rn.1 yy SECTION ONE: REQUESTING A SCOPING MEETING ONLY ❑ Scoping Meeting ONLY ❑ DWR, ❑ DCM, ❑ DEMLR, ❑ OTHER: e./ SECTION TWO: CHECK ONLY THE PROGRAM (S) YOU ARE REQUESTING FOR EXPRESS PERMITTING ❑ 401 Unit ❑Stream Origin Determination: _ # of stream calls —Please attach TOPO map marking the areas in question's ❑ IntermittentlPerennial Determination: _ # of stream calls — Please attach TOPO map marking the areas in questions ❑ 401 Water Quality Certification ❑ Isolated Wetland (_linear it or _acres) ❑ Riparian Buffer Authorization ❑ Minor Variance ❑ Major General Variance ® State Stormwater ❑ General ❑ SFR, ❑ SFR < 1 ac. ❑ Bkhd & Bt Rmp, ❑ Clear & Grub, ❑ Utility ❑ Other ❑ Low Density ❑ Low Density -Curb & Gutter _ # Curb Outlet Swales ❑ Off -site [SW (Provide permit #)] ® High Density -Detention Pond i # Treatment Systems ❑ High Density -Infiltration _ #Treatment Systems ❑ High Density -Bio-Retention _ # Treatment Systems ❑ High Density —SW Wetlands _ # Treatment Systems ❑ High Density -Other _ # Treatment Systems / ® MOD:® Major ❑ Minor ❑ Plan Revision ❑ Redev. Exclusion SW 8060530 (Frrovide penult #) ❑ Coastal Management ❑ Excavation & Fill ❑ Bridges & Culverts ❑ Structures Information ❑ Upland Development ❑ Marina Development ❑ Urban Waterfront Quality ® Erosion and Sedimentation Control Plan with .1_10 acres to be disturbed. (CK # & Amt. (for DEO use)) I THREE — PLEASE CHECK ALL THAT IS APPLICABLE TO YOUR PROJECT (for both scoping and express meeting request) Wetlands on Site ❑ Yes ® No Wetlands Delineation has been completed: ® Yes ❑ No US ACOE Approval of Delineation completed: ® Yes ❑ No Received from US ACOE ❑ Yes ® No For DE Q use Fee SDlit for multiple vermits: (Check # ) Buffer Impacts: ® No ❑ YES: acre(s) Isolated wetland on Properly ❑ Yes ® No 404 Application in Process w/ US ACOE: ❑ Yes ® No Permit Amount SUBMITTAL DATES Fee I SUBMITTAL DATES Fee CAMA $ Variance (❑ Mal; ❑ Min) - S SW (❑ HD, ❑ Li ❑ Gen) $ 401: S LQS $ Stream Deter,_ S NCDEQ EXPRESS March 2016 UNC-WILMINGTON— HURST HAMILTO.N PARKINC LOTS A'C'DEO Egress Reyuc.cl A'arrative General Description Located at the intersection of Hurst Drive and I lamilton Drive. the Ilurst Parking Lots project will consist of hvo (2) surface parking lots providing it total of +/- 574 spaces to accommodate visitors and students. The proposed lots are anticipated to contain one entrance ofT Hurst. one exit onto Hamilton, and one two-way access to N. MacMillan Drive. The project will include the addition of hike parking stalls. a bus shelter; along with it modification to an existing. adjacent SCM (i.e. the Lot K pond). The project is located within the Cape Pear River Basin. with stormwater runoff from the proposed project draining to Burnt Mill Creek. According to the N.C. Division of Water (Quality BasinWide Information Management System (RIMS), the waterway is classified as C; Sw" at this location (Stream Index 4 18-74-63-21). Please refer to the attached conceptual layout for more information and the location of the proposed parking Tots. Discussion o/'Proposer/Stormwaler Management The proposed project will be high density and will require a major modification to the existing State Stormwwater Management Permit (S`.>F'8 060530 —attached) in this area of the UNCW campus. The addition of the surface parking lots will require an expansion to the existing SWS 060530 permit boundary. To better mimic the true drainage area to the Stormwater Control Measure (SCM). the modified permit boundary will now include existing BIJA that has been previously unaccounted for, meaning that the SCM will be designed to provide equal or better treatment for the net increase in 13L A for this modified permit boundary. The existing Lot h pond will be renovated / expanded to accommodate the proposed increase in impervious area. As it result of the increase in 1.3UA and expansion of the existing SCM, the wet pond design will be modified to meet the Minimum Design Criteria. Discussion ol'Proposed Erosion Control In advance of parking lot construction (i.e. site grading. installation of storm drainage. construction of built upon area, etc.), UNCW is proposing to move forward with clearing and grubbing of the project area as it separate project. To accomplish this work, an erosion control plan will be submitted for review and approval in advance of construction drawings for the parking lot. Erosion control on this site will consist of sediment basins, diversion ditches, slope drains, silt fence, and silt fence outlets. Any inlets, either existing or proposed will be protected with inlet protection along with other requirements necessary for compliance with an approved erosion control permit (e.g. construction entrances, temporary and permanent seeding, etc.). The proposed disturbed area is +/-9 ac. d 1. i� McADaras .0 .% g6 I � \ I t t is ��\ �iC�) 1' � i� \ s®. .�" f t� i;t� % / Q�✓ Et. may`. '2} 0 ILLUSTRATIVE MASTER PLAN FOR: r UNCW, PARKING LOT ��'��. °LY�7-2 r I I I 1 WILMINGTON, NORTH CAROLINA Hall, Christine From: Stubbs, Rebecca <rstubbs@mcadamsco.com> Sent: Thursday, November 09, 2017 4:26 PM To: Hall, Christine Cc: Perry, Daniel Subject: [External] SW8 060530 Express Request - Updated Package Attachments: 2017-11-09 UNW-17060 Request for SW Express Permit.pdf CAUTION: External email. Do not click links or open attachments unless verified. Send all suspicious email as an attachment to report.spam@nc.gov. Good Afternoon Christine, Thank you for your time yesterday to discuss the scope of the Hurst Hamilton Parking Lot project. I have attached an updated Express Request form and a revised narrative as requested for this project. If I can provide you with any additional information to set the date for the Express Review, please let me know. I hope you enjoy your Veteran's Day off! Thanks, Rebecca Stubbs, El I Designer II, Water Resources + Infrastructure r McAdams` 2905 Meridian Parkway, Durham, NC 27713 office 919. 361. 5000 x224 I direct 919. 287. 0740 1 rstubbs@mcadamsco.com www.mcadam'sco.com1 linkedin•I twitter I instazram I join our team �=J MCADAMS creating experiences through experience . 1 10 0 s j per... Fo, HO Use ONLY Reviewer. North Caro I ina Department of Env iron menta I Quality sears ) Request for Express Permit Review `y �3qqqq Time y (q lrrte FILL-IN all the information below and CHECK the Permit(s) you are requesting for express review. Call and Email the completed form to the Permit Coordinator along with a completed DETAILED narrative site plan (PDF file) and vicinity map (same items expected in the application package oftheprojectlocation. Please include this form in the application package. • Asheville Region -Alison Davidson 828.296-4698;alison.davidson(ddancdenr.gov • Fayetteville or Raleigh Region -David Lee 919-791-4203;david.lee(ancdenr.gov • Mooresville or Winston Salem -Marcia Allocco 704-235-2107; marcia.allocco(dncdenr.pov • Washington Region -Lyn Hardison 252-948-3842orlvn.hardison(dpncdenr.gov • Wilmington Region -Cameron Weaver 910-796-7303 or cameron.weaven@,ncdenr.gov NOTE: Project application received after 12 noon will be stamped in the following work day. Project Name: HURST PARKING LOTS County: NEW HANOVER Applicant RACHELPATRICK Company:UNCW Address: 601 S COLLEGE ROAD City. WILMINGTON. State: NC Zip: 28403 Phone: 910-962-7743, Fax:910-962-7140, Email. ahp ickrw@uncw.edu Ph I L ti SW 8980405 SW _ SWDE_ NPS _ NPDES_Q W wo —_ E&S _ E&S _ Other on: S #_ JOBS SECTION ONE: REQUESTING A SCOPING MEETING ONLY RECT OCT 2 4 20171 ❑ Scoping Meeting ONLY ❑ DWR, ❑ DCM, ❑ DEMLR, ❑ OTHER: SECTION TWO: CHECK ONLY THE PROGRAM (S)YOU ARE REQUESTING FOR EXPRESS PERMITTING ❑ 401 Unit ❑ Steam Origin Defarmrnaton _ # of steam calls — Please attach TOPO map marking the areas in questions ElIntermil;EntlPerennial Determination: _ # of stream calls - Please attach TOPO map marking the areas in questions ❑ 401 Water Quality Certification ❑ Isolated Wetland (_linear ff'or _acres) ❑ Riparian Butler Authorization ❑ Minor Variance ❑ Major General Variance ® StateStormwaler ISW - Scoping Only ❑ SFR < 1 ac. ElBkhd & Bt Rmp, ElClear & Grub, El Utility ElOther ❑ Low Density ow ensi - ur utter _ ,Curb Outlet Swales ❑ OtFsito [SW _ (Provide perml #)] ® High Densily-Detention Pond 1 # Treatment Systems ❑ High Density -Infiltration _ #Treatment Systems ❑ High Density -Bio-Retention _ # Treatment Systems ❑ High Density -SW Wetlands _ It Treatment Systems ® High Density -Other _ It Treatment Systems /® MOD:❑ Major ® Minor ❑ Plan Revision ❑ Redev. Exclusion SW 8060530 (Provide permiu) ❑ Coastal Management ❑ Excavation & Fill ❑ Bridges & Culverts ❑ Structures Information ❑ Upland Development ❑ Marina Development ❑ Urban Waterfront ® Land Quality ® Erosion and Sedimentation Control Plan with .al_10 acres to be disturbed. (CK # & Am (for DEO use)) SECTION THREE - PLEASE CHECK ALL THAT IS APPLICABLE TO YOUR PROJECT (for both sopping and express meeting request) Wetlands on Site ❑ Yes Z No Buffer Impact: ® No ❑ YES: —acre(s) Wetlands Delineation has been completed: ® Yes ❑ No Isolated wetland on Property ❑ Yes ® No US ACOE Approval of Delineation completed: ® Yes ❑ No 404 Application in Process wl US ACOE: ❑ Yes ® No Permit Received from US ACOE ❑ Yes ® No For I)FO use onh Fee Solitfor multiole oermils:(Check# ) Total FeeAmountS SUBMITTAL DATES Fee SUBMITTAL DATES Fee CAMA s Variance(❑ Maj;❑ Min) 5 SW (❑ HD, ❑ LD, O Gen) s 401: s Los S Stream Deter s NCDEQ EXPRESS March 2016,�rt „�, ,� .�,^[ 1/ T l� �e-�h ` ' �"ec^ \h r ✓`'`�� ZINC-W'ILMINGTON —I I URST PARKING LOTS NCDEQ Express Request Narrative General Description Located at the intersection of Hurst Drive and Hamilton Drive, the Hurst parking Lots project will consist of two (2) surface parking lots providing a total of +/- 574 spaces to accommodate visitors and students. The proposed lots are anticipated to contain one entrance off Hurst, one exit onto Hamilton. and one two-way access to N. - MacMillan Drive. The project will include the addition of bike parking stalls, a bus shelter, along with a modification to an existing, adjacent BMP (i.e. the Lot K pond). In addition, and if feasible, the project scope includes a portion of the Hurst / Hamilton Lot parking lot to be permeable pavement. The project is located within the Cape Pear River Basin, with storruwater runoff from the proposed project draining to Burnt Mill Creek. According to the N.C. Division of Water Quality BasinNide Information Management System (BIMS), the waterway is classified as C; Sw" at this location (Stream Index 9 18-74-63-2). Please refer to the attached conceptual layout for more information and the location of the proposed parking lots. Discussion of Proposed Stormwater Management The proposed project will be high density and will require a major modification to the existing State Stormwater Management Permit (SW8 060530 — attached) in this area of the lNC\V campus. The existing Lot K pond will be renovated / expanded to accommodate the proposed increase in impervious area and the parking lots will also incorporate pervious pavement to the extent possible. In addition, and in advance of submittal of formal design drawings / calculations; attached is a hydrogeologic evaluation that has been prepared as pan of the documentation that is required to relax the 24-inch separation between infiltration system and the seasonal high-water table (SI-MIT). Discussion of Proposed Erosion Control In advance of parking lot construction (i.e. site grading, installation of storm drainage, construction of built upon area, etc.), lNCW is proposing to move forward with clearing and grubbing of the project area as a separate project. To accomplish this work, an erosion control plan will be submitted for review and approval in advance of construction drawings for the parking lot. Erosion control on this site will consist of sediment basins, diversion ditches, slope drains, silt fence, and silt fence outlets. Any inlets, either existing or proposed will be protected with inlet protection along with other requirements necessary for compliance with an approved erosion control permit (e.g. construction entrances, temporary and permanent seeding, etc.). The proposed disturbed area is +/-9 ac. ECS SOUTHEAST, LLP Setting the Standard for Service --=r. Geotechnical • Construction Materials - Environmental • Facilities nG FeGrmcr, Gu,op•ss rrtm G-'0^ L;; Y?omsivrrxi @n�irrmn Fmm J"83 October 4, 2017 Mr. Brandon Finch McAdams 2905 Meridian Parkway Durham, North Carolina 27713 Reference: Report of Hydrogeologic Evaluation Green Tract Parking - UNCW Wilmington, New Hanover County, North Carolina ECS Project No. 49.5091 . Dear Mr. Finch: ECS Southeast, LLP (ECS) was requested to observe the seasonal high water table (SHWT) and to perform infiltration testing at twenty locations within the stormwater control measure (SCM) area(s) at the parcel located between Hamilton Drive and Hurst Drive on the UNCW campus in Wilmington, New Hanover County, North Carolina (Figure 1). ECS was then requested to provide a Hydrogeologic Evaluation of the site in accordance to the North Carolina Department of Environmental Quality (NCDEQ) standard for relaxing the 24-inch separation between infiltration systems and the SHWT. This letter, with attachments, is the report of our evaluation. Field Testing On August 2V, 241", and 25`', 2017, ECS conducted an exploration of the subsurface soil and groundwater conditions at twenty requested locations. These locations are shown on the attached Boring Location Plan (Figure 2). ECS located the borings by using a site plan provided by McAdams. The purpose of this exploration was to obtain subsurface information of the in - situ soils for the SCM area(s). ECS explored the subsurface soil and groundwater conditions by advancing one hand auger boring into the existing ground surface at each of the requested boring locations. ECS visually classified the subsurface soils and obtained representative samples of each soil type encountered. ECS also recorded the SHWT, based on visual observation of penetrated soils, and groundwater elevation observed at the time of the hand auger borings. The attached Infiltration Testing Form provides a summary of the subsurface conditions encountered at the hand auger boring locations. The SHWT and groundwater elevation was estimated at the boring locations below the existing grade elevation. A summary of the findings are as follows: Location SHWT Groundwater 1-1 6 inches 30 inches 1-2 6 inches 36 inches 1-3 6 inches 34 inches 1-4 6 inches 32 inches 1-5 8 inches 30 inches 1-6 10 inches 36 inches 1-7 6 inches 36 inches 1-8 20 inches 38 inches ECS Capitol Seaices. PLLC • ECS Florida. LLC - ECS Md-AtianSc. LLC • ECS ivlid=Nest LLC • EGS Southeast, LLP • ECS texas, UP w,wV.ecsll+ni ted.Con) Report of Hydrogeologic Evaluation Green Tract Parking - UNCW Wilmington, New Hanover County, North Carolina ECS Project No. 49,5091 October 4, 2017 1-9 22 inches 36 inches 1-10 6 inches 32 inches 1-11 14 inches Winches 1-12 6 inches 24 inches 1-13 6 inches 30 inches 1-14 15 inches 32 inches 1-15 20 inches 36 inches 1-16 18 inches 48 inches 1-17 16 inches 36 inches 1-18 18 inches 32 inches 1-19 18 inches 32 inches 1-20 16 inches 30 inches ECS has conducted twenty infiltration tests utilizing a compact constant head permeameter near the hand auger borings in order to estimate the infiltration rate for the subsurface soils. Infiltration tests are typically conducted at two feet above the SHWT or in the most restrictive soil horizon. Tests in clayey conditions are conducted for durations of up to 30 minutes. If a more precise hydraulic conductivity value is desired for these locations; then ECS recommends collecting samples by advancing Shelby tubes and performing laboratory permeability testing. Field Test Results Below is a summary of the infiltration test results: Location Description Depth Inches/ hour 1-1 Black silty SAND 10 inches 0.20 1-2 Black silty SAND 10 inches 0.47 1-3 Black silty SAND w/ clay lens 10 inches 0,067 1-4 Black silty SAND 10 inches 0.10 1-5 Black silty SAND 10 inches 0.11 1-6 Black/gray silty SAND 10 inches 0.22 1-7 Black silty SAND 10 inches 0,042 1-8 Gray silty SAND w/ sand lens 10 inches 0.25 1-9 Gray fine SAND w/ silt 10 inches 2.82 1-10 Black silty SAND 10 inches 0.09 1-11 Black/gray silty SAND 10 inches 0.11 1-12 Black silty SAND 10 inches 0.081 1-13 Black silty SAND 10 inches 0.12 1-14 Brown/gray silty SAND 10 inches 0.17 1-15 Black/brown silty SAND 10 inches 0.63 1-16 Gray silty SAND 10 inches 0.061 1-17 Black silty SAND w/ clay 10 inches 0.042 1-18 Gray silty SAND 10 inches 0.20 1-19 Gray silty SAND 10 inches 0.26 Report of Hydrogeologic Evaluation Green Tract Parking - UNCW Wilmington, New Hanover County, North Carolina ECS Project No. 49.5091 October 4, 2017 -20 1 Gray silty SAND 1 10 inches 1 0.22 Infiltration rates and SHWT may vary within the proposed site due to changes in elevation and subsurface conditions. Hydrogeologic Evaluation There are required components listed in the NCDEQ Stormwater Design Manual in order to reduce the 24-inch separation between infiltration systems and the SHWT. In order to evaluate thehydrogeologic conditions of an area designated for an infiltration SCM, these components are evaluated. Below are the required component descriptions for this site. • The site is located in the Coastal Plain Physiographic Province. The Coastal Plain is composed of seven terraces, each representing a former level of the Atlantic Ocean. Soils in this area generally consist of sedimentary materials transported from other areas by the ocean and rivers. These deposits vary in thickness from a thin veneer along the western edge of the region to more than 2,000 feet near the coast. The sedimentary deposits of the Coastal Plain were deposited upon consolidated rocks similar to those underlying the Piedmont and Mountain Physiographic Provinces. The groundwater flow direction is believed to be to the east towards Bradley Creek and the Atlantic Ocean. • The majority of the site was observed to be relatively flat having approximately the same elevation across the site. The site is bordered by Hamilton Drive, Hurst Drive, and MacMillan Ave. The site has a stormwater treatment SCM for the apartment complex to the northwest of the site. No abandoned wells or rock outcrops were observed. • Based on regional geology and observations made in previous geotechnical borings (B- 6) advanced by ECS in July of 2005 (see attached boring logs), the site consists of surficial deposits of sandy sediment with silt up to 35 feet in depth. No rock or confining layer was observed up to 40 feet. The marine Pee Dee Formation, which is generally comprised of sand, clayey sand, and clay that was deposited during the Cretaceous, then underlies the surficial sediment at depths greater than 40 feet. • The hydraulic conductivity of the surficial sediment was tested and resulted in a range from 0.081 to 2.82 inches per hour at the test locations. Transmissivity, which is equal to hydraulic conductivity multiplied by saturated aquifer thickness, was calculated using the low and high conductivity values from this site and saturated aquifer thickness (approximately 44 feet) was calculated based on the depth to a consolidated geologic layer encountered while drilling nearby geotechnical boring B-6 (47 feet) and depth to groundwater measurements from the site (approximately 3 feet below ground surface). Based on the range of hydraulic conductivity values measured at the site, the range of transmissivity values was determined to be between 42.8and 1,489.0 inches squared per hour, respectively. 3 Report of Hydrogeologic Evaluation Green Tract Parking - UNCW Wilmington, New Hanover County, North Carolina ECS Project No. 49.5091 October 4, 2017 • The SHWT was observed to range from 6 to 22 inches below the existing grade elevation at the locations tested. • The surficial aquifer of the site consists of silty/sandy conditions where groundwater flows without confining conditions. The site currently consists of two stand-alone structures with a parking lot and landscaped areas. Stormwater is currently being treated by an onsite infiltration system and a swale system. A proposed infiltration SCM (pervious pavement) is to be constructed in order to contain and treat the runoff of the anticipated impervious areas. • Recharge to the shallow, unconfined aquifer consists of surface infiltration of precipitation and irrigation of the vegetated portions of the site. The groundwater receptors in the area consist of stormwater ponds located to the north and east of the site. The groundwater discharge feature is Bradley Creek. The topography of the area is relatively flat and the subsurface flow media consists of silty sands and sands with silt which results in minimal surface water movement in the swales with most surface water removal by infiltration. The replacement of the impermeable parking areas with pervious pavement will reduce the surface runoff into the swales while allowing more area of the site to absorb the surface water via infiltration. The pre and post flow calculations for the site were generated by McAdams and are included in the attachments. • A mounding analysis was generated utilizing the United States Geological Survey (USGS) spread sheet solving the Hantush (1967) equation for groundwater mounding beneath an infiltration basin. The data used for calculating the mounding conditions were collected from site specific field data, design data, and soil characteristics. On the chart, (R) represents a one inch storm event over a 12 hour period. Specific yield (Sy) was estimated by referencing the USGS Compilation of Specific Yield for Various Materials by A.I. Johnson, 1963. Hydraulic conductivity (K) was determined in the field and is referenced in the text above. Basin dimensions (X and Y) were provided by McAdams (the site civil designer). There will be several sections of pervious pavement to be constructed, ECS chose the largest pervious section for this calculation. Time (T) is the 3 day period set forth by NCDEQ for an infiltration basin to function. Thickness of saturated zone HI(0) was derived by subtracting the depth to the less permeable underlying consolidated layer (approximately 47 feet) from the depth to groundwater (3 feet). This calculation uses the median hydraulic conductivity represented by the tests that were conducted. The spreadsheet is included with the attachments. 4 Report of Hydrogeologic Evaluation Green Tract Parking - UNCW Wilmington, New Hanover County, North Carolina ECS Project No. 49.5091 October 4, 2017 Closure ECS's analysis of the site has been based on our understanding of the site, the project information provided to us, and the data obtained during our exploration. If the project information provided to us is changed; please contact us so that our recommendations can be reviewed and appropriate revisions provided, if necessary. The discovery of any site or. subsurface conditions during construction which deviate from the data outlined in this exploration should be reported to us for our review, analysis and revision of our recommendations, if necessary. The assessment of site environmental conditions for the presence of pollutants in the soil and groundwater of the site is beyond the scope of this geotechnical exploration. ECS appreciates the opportunity to provide our services to you on this project. If you have any questions concerning this report or this project, please contact us at (910) 686-9114. Respectfully, ECS SOUTHEAST, LLP a K. Brooks Wall Project Manager bwall(abecslimited.com 910-686-9114 Attachments: Figure 1 — Boring Location Plan Infiltration Testing Form Geotechnical Boring Logs USGS Mounding Spreadsheet ASFE Document M ;� Michael L. Maloy, C.P.G. Principal Geologist mmaloy(a)ecslimited. com 540-785-6100 i - - ;1 .A .A.. B T l '", a i �h Y R.��- � r'.,��s1Sj€�� �tiµW r•*' �y �. ✓''} ^'`t.,y yay lU11IJ!`�l T4,c t 1 ,�•* 't f ,1 'i'�i.�t� ,l Yc{ � � t^4 r b}r� �u�- `SI/nY �^wri 1 Y'"" ` / `',,Gt`S+ rt,} %� AnyCK i t+ aCuj hr' �i '. r; !z ® APPROXIMATE BORING LOCATIONS SCALE SHOWN ABOVE Green Tract Parking Lot, UNCW. Wilmington, New Hanover County, North Carolina ECS Project # 49.5091 August 23, 24, 25, 2017 KBW N W*E s Figure 2— Boring Location Plan Provided by: Google Earth Infiltration Testing Form Green Tract Parking Wilmington, New Hanover County, North Carolina ECS Project No. 49.5091 August 23rd 24th 25th 2017 Location Depth USCS Soil Description 1-1 0-30" SM Black silty SAND Seasonal High Water Table was estimated to be at 6 inches below the existing grade elevation. Groundwater was encountered at 30 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.20 inches per hour Location Depth USCS Soil Description 1-2 0-24" SM Black silty SAND 24"-48" SW Gray fine SAND w/ silt Seasonal High Water Table was estimated to be at 6 inches below the existing grade elevation. Groundwater was encountered at 36 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.47 inches per hour Location Depth USCS Soil Description 1-3 0-36" SM Black silty SAND w/ clay lens Seasonal High Water Table was estimated to be at 6 inches below the existing grade elevation. Groundwater was encountered at 34 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.067 inches per hour Infiltration Testing Form Green Tract Parking Wilmington, New Hanover County, North Carolina ECS Project No. 49.5091 August 23rd 24tn 251n 2017 Location Depth USCS Soil Description 1-4 0-36" SM Black silty SAND Seasonal High Water Table was estimated to be at 6 inches below the existing grade elevation. Groundwater was encountered at 32 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.10 inches per hour Location Depth USCS Soil Description 1-5 0-36" SM Black silty SAND Seasonal High Water Table was estimated to be at 8 inches below the existing grade elevation. Groundwater was encountered at 30 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.11 inches per hour Location Depth USCS Soil Description 1-6 0-18" SM Black/gray silty SAND 18"-36" SW Gray fine SAND w/ silt Seasonal High Water Table was estimated to be at 10 inches below the existing grade elevation. Groundwater was encountered at 36 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.22 inches per hour Infiltration Testing Form Green Tract Parking Wilmington, New Hanover County, North Carolina ECS Project No. 49.5091 August 23rd 24th 25th 2017 Location Depth USCS Soil Description 1-7 0-36" SM Black silty SAND Seasonal High Water Table was estimated to be at 6 inches below the existing grade elevation. Groundwater was encountered at 36 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.042 inches per hour Location Depth USCS Soil Description 1-8 0-20" SW Gray silty SAND w/ sand lens 20-48" SM Black silty SAND Seasonal High Water Table was estimated to be at 20 inches below the existing grade elevation. Groundwater was encountered at 38 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.25 inches per hour Location Depth USCS Soil Description 1-9 0-14" SW Gray fine SAND w/ silt 14-36" Sc Tan fine SAND w/clay Seasonal High Water Table was estimated to be at 22 inches below the existing grade elevation. Groundwater was encountered at 32 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 2.82 inches per hour Infiltration Testing Form Green Tract Parking Wilmington, New Hanover County, North Carolina ECS Project No. 49.5091 August 23rd 24th 25th 2017 Location Depth USCS Soil Description 1-10 0-36" SM Black silty SAND Seasonal High Water Table was estimated to be at 6 inches below the existing grade elevation. Groundwater was encountered at 32 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.09 inches per hour Location Depth USCS Soil Description 1-11 0-40" SM Black/gray silty SAND Seasonal High Water Table was estimated to be at 14 inches below the existing grade elevation. Groundwater was encountered at 36 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.11 inches per hour Location Depth USCS Soil Description 1-12 0-36" SM Black silty SAND Seasonal High Water Table was estimated to be at 6 inches below the existing grade elevation. Groundwater was encountered at 36 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.081 inches per hour Infiltration Testing Form Green Tract Parking Wilmington, New Hanover County, North Carolina ECS Project No. 49.5091 August 23rd 24th 25tn 2017 Location Depth USCS Soil Description 1-13 0-36" SM Black silty SAND Seasonal High Water Table was estimated to be at 6 inches below the existing grade elevation. Groundwater was encountered at 30 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.12 inches per hour Location Depth USCS Soil Description 1-14 0-36" SM Brown/gray silty SAND Seasonal High Water Table was estimated to be at 15 inches below the existing grade elevation. Groundwater was encountered at 32 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.17 inches per hour Location Depth USCS Soil Description 1-15 0-36" SM Black/brown silty SAND Seasonal High Water Table was estimated to be at 20 inches below the existing grade elevation. Groundwater was encountered at 36 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.63 inches per hour Infiltration Testing Form Green Tract Parking Wilmington, New Hanover County, North Carolina ECS Project No. 49.5091 August 23rd 241n 251n 2017 Location Depth USCS 1-16 0-24" SM 24-48" Sc Soil Description Gray silty SAND Tan/orange clayey SAND Seasonal High Water Table was estimated to be at 18 inches below the existing grade elevation. Groundwater was encountered at 48 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.061 inches per hour Location Depth USCS Soil Description 1-17 0-36" SM Black silty SAND w/ clay Seasonal High Water Table was estimated to be at 16 inches below the existing grade elevation. Groundwater was encountered at 36 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.042 inches per hour Location Depth USCS Soil Description 1-18 0-101, SM Gray silty SAND 10-36" Sc Black silty SAND Seasonal High Water Table was estimated to be at 18 inches below the existing grade elevation. Groundwater was encountered at 32 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.20 inches per hour Infiltration Testing Form Green Tract Parking Wilmington, New Hanover County, North Carolina ECS Project No. 49.5091 August 23`d 24th 251h, 2017 Location Depth USCS Soil Description 1-19 0-36" SM Gray silty SAND Seasonal High Water Table was estimated to be at 18 inches below the existing grade elevation. Groundwater was encountered at 32 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.26 inches per hour Location Depth USCS Soil Description 1-20 0-36" SM Gray silty SAND Seasonal High Water Table was estimated to be at 16 inches below the existing grade elevation. Groundwater was encountered at 30 inches below the existing grade elevation. Test was conducted at 10 inches below existing grade elevation Infiltration Rate: 0.22 inches per hour a1ffin' ram ; Boma / RRW rn�a�¢� UNCW 11407 B-6 1 or 3 >mo.Bn T NAM Parkin Deck �fWf-EBaIlI= Laura Miller � R, = BaE Socp7lar � aeaB� Wllmin ton, North Carolina "�8+ 1 e nIBURZIoB OF NVERI L PUBr[a TAM urQ % 00121W am a----1r um e gg It Heat QUA= aSUMUME a MwWffi EIPaf� LRa18 SWAM ELWAT 0H ■ ammm ® KomlvPlP�1811 Asphalt Depth 2' 1 SS 18 IB 13 po-re} ABC Stone Depth 4' 13.8 Medium Denss, Light Brown to 2 SS 18 18 Dark Brown, Silty Fine to 5 Medium SAND, (SM) EB ao-w-10 Loose to Medium Dense, Brown to 3 SS 18 18 Tan to Croy. Fine to Medium, 241r-n-u) SAND, (SP) 1 4 SS 18 18 :•'.•: 15 ::lt L ID 5 SS 1B 18 ICY: 6 SS 18 18� 20 l�l 7 SS 18 18T: 25 N 16 ry-91) B SS 18 18 30— CON71NUED ON NEXT PAGE. nc marvswrmn LV4X xF WMa rrc APFRMWATE 7arm%ar 6s¢s Bmam wm rya s+-ata M rRABSrrM My a macaw. yn. 6'2" `e an ® BaRMa saw 6/18 OS TWAH1 iwgio B0309 COMP» 6 18 05 assa Br Ham. fir° Bm D-25 ro=Km PB ruW Mud Rotary cuiM UNCW PRO= RAW Parkin Deck ram 0 Balms / SEW 11407 B-6 2 or 3 Laura Miller • ens 10cA2 Wilmin ton, North Carolina aum . 1 B a e+ MMCRWTa1Q OF KAnW& ENGL H tAm1919 Pus= WAM law UW s cat 20. x uW % B zL e ieLs QUA= UWMUU= • 9EL7vi, RQDX 10 60 so 40 aw 3 3 4 50 55 60 Loose to Medium Dense, Brown to Tan to Gray, nne to Medium, SAND, (SP) ai ':`' - 10 ("-e) 20 02-10-M (a tt aB 37 ---=----'--' 9 SS 18 18 10 SS IB 18 11 SS is IB Dense to Very Dense, Light Gray, Cemented SAND 12 SS 18 18 NO RECOVERY Cemented Sand) - - - - - - - - - - - - -- L CONTINUED ON NEXT PAGE. TNC T MTWWATM LDQ W-NEW(T TW APFRmamTE B mmy Lum BErwax sai Tym at-aw rc Tknwrm my a smwaL VvL 6'2" ■B as ® soon agar® b 18 05 TWUM i Boom caBe'a® 6 18 05 carve ar om e TWL = D-25 qua PB meum mem Mud Rotary CLUW UNCW roe 0 11407 BOF Ma 1 B-6 3 or 3 t_c --.-. reolacr xA= Parking Deck ARCffr"=-XKGVM e Laura Miller am Iocet= Wilmin ton, North Carollna 5 -o- calms PMasmalm t e a e+ F DENEWTM aF MA79MAL sRcatax mots Flesev Tam Um Um x cw2w x um E x sea gMUM a waywim Io w so 40 eo« sonraoa alxvetton 6 7 7 85 90 NO RECOVERY (Cemented Sand) — - — — END Or BORING ® 65.0' Tx ST"Tv=T= LatS RSPIE4M nt APPFAWMTE M11 W LINOS SKTWM ML TYPES VJ-4M Ti mwT= my It mmw Y*L 692„ IM OR 0 s®e RUM 6 18 05 i•waf eolmea COMPIAMM 6 18 05 Gave .IR zam e AWL ® D-25 FwwM+ PB rwam MMW Mud Rotary This smeadsheet will calculate the neignt of a"ounel mound beneath a stmmwrime infilvation basin. More Infar-ration can be for In the Us. Geological Survey Scientific Inver:igavons Reoort 20'.0 5102 "Slnclation of gonsarr :e: numi g berm momment.1 Izi,e nwate: in.iltra:ian oasi.,". 71cuser m tsnecdy inpltrule,role (R), specific vie Io(Sy), F.Fmnta l bvorau I,r ror lvl tY(Khl losm.croensicns(x,y), d u racoon of all It: atop one.(1), and the Initial tnickness of toe saturated zone (ai(0), neigh: of :he ware: table if tee bottom of the aquifer is me datum). For a scuare oasis ^re half widen edust, the half lengtn (v = y). For a rectangular basic, if the use: wane, the wale::aole change, ace: nehcmlar to toe long side, sdeci`.y r as me soon dimension ane y as toe long dimension. conversely, If :he Lserwatts the values perpendicular to:.hesinct sic or seedily y as the ste-t cincensor,r, as the org dim ensior. A l l distances a to from the center of the dasim. users can change the distances from the center of the basin a: wFic r water :able aquifer thickness are calculated Cells In in yellow are values tnat cars he. Inanged by the usercells nighllgmed'mred are output values based be user-sheof ed inputsthe user MUS121ick the blue el e-Calmlate Now' butmp each time ANY of the user -specified inputs an! changedothervdse.necess,ey ite: cidns to cone gd oo the correct solution will at no cache aoc values shown will be Incorrect. Use cohsis:en:urisf0r all Inner values (for example, fee: ane days) In but values A R Sy K x y t blip) llllllllllll4_St563J h ream) 171— Ah(max) Ground. Distance from water center of basin Mounding, in in xdindramr, in feet feet a 20 40 50 60 70 80 90 100 Disclaimer cse eoais:en; ur.its (e.p,. (detR Gays or lnchesR hnms) Comenion Table im/hpur feet/day Recharge (infiltration) rate (feet/day) 0.67 1.33 Specific yield, Sy (dimensionless, between 0 and 1) H o ran nta l all AD l is eo ad uetivity, Kh (fad/day)` 7.00 4,00 in he noon aternsuoy,, thissprcam,er, 1/2 length of basin is, direction, in feet) (USGS se 7010 5102), vertical soil permeability 1/2 width of basin(y direction, in feet) hours days ford), red,ded to tedpomptn nmhdnIal duration of infiltration period (days) 36 150 nydr,uIh, ndoamdy(t/cl. Initial thickness of saturated zone (feet) maximum thickness of saturated zone (beneath center of basin at end of infiltration'peric d) maximum groundwater mounding (beneath center of basin at end of infiltration period) ®Re -Calculate Now I I I Groundwater Mounding, in feet t.goo 1.600 1,700 1,700 i : 000 o.zao .400 0.200 0 20 40 so eo 100 120 :40 This spreadsheet solving the Hantush (1967) equation for ground -water mounding beneath an infiltration basin is made available to the general public as a convenience for those wishing to replicate values documented in the USGS Scientific Investigations Report 2010-5102 "Groundwater mounding beneath hypothetical stormwater infiltration basins" or to calculate values based on user -specified site conditions. Any changes made to the spreadsheet (other than values identified as user -specified) after transmission from the USGS could have unintended, undesirable consequences. These consequences could include, but may not be limited to: erroneous output, numerical instabilities, and violations of underlying assumptions that are inherent in results presented in the accompanying USGS published report. The USGS assumes no responsibility for the consequences of any changes matle to the spreadsheet. If changes are made to the spreadsheet, the user is responsible for documenting the changes and justifying the results and conclusions. Geolechnical Engineering Report Geotechnical Services Are Performed for Specific Purposes, Persons, and Projects Geotechnical engineers structure their services to an, the specific needs of Cneir clients, A geoiechnical engineering study conducted for a civil engineer may not fulfill the needs of a construction contractor or even another civil engineer. Because each geotechnical engineering study is unique, each geo- technical engineering report is unique, prepared solelylor the client No one except you should rely on your geotechnical engineering report without first conferring with the geofechnlcal engineer who prepared it And no one - not even you -should apply the report for any purpose or project except the one originally contemplated. Read the Full Report Serious problems have occurred because those relying on a geotechnical engineering report did not read it all. Do not rely on an executive summary. Do not read selected elements only. A Geotechnical Engineering Report Is Based on A Unique Set of Project -Specific factors Geoiechnical engineers consider a numher of unique, project -specific factors when establishing the scope of a study. Typical lactors include: the client's goals, objectives, and risk management preferences. the general nature of the structure involved, its size, and configuration; the location of the structure on the site; acid other planned or existing site improvements, such as access roads, parking lots, and underground utilities. Unless the geotechnical engi- neer who conducted the study specifically indicates othervdise, do not rely on a oeoiechnical engineering report that was: • not prepared for you, • not prepared for your project, • not prepared for the specific site explored, or • completed before important project changes were made. Typical chances that can erode the reliability of an existing geotechnical engineering report Include those that affect: • the function of the proposed structure, as when it changed from a parking garage to an office building, or from alight industrial plant to a refrigeraied warehouse, • elevation, comicuratlon, location, orientation, or welgni of the proposed structure, • composition of the design team, or • project ownership. As a general rule, aPways inform your geotechnical enoineer of project changes - even minor ones - and request an assessment of their impact. rieotechnical engineers cannot accent responsibility or liability mrproblems that occur because their reports do not consider developments of which they were not informed. Subsurface Conditions Can Change A geotechnical engineering report is based on conditions that existed at the time the study was performed. Do not rely on a geotechnical engineering report whose adequacy may have beer, affected by: the passage of time. by man-made events, such as construction on or adjacent to the site, or by natu- ral events, such as floods, earhqua:xes, or groundwater fluctuations. Always contact the geotechnical engineer before applying the report to determine if it is still reliable. Aminor amount of additional testing or analysis could prevent major problems. Most Geotechnical Findings Are Professional Opinions Site exploration identifies subsurface conditions only at those points where subsurface tests are conducted or samples are taken. Geoiechnical engineers review field and laboratory data and then apply their professional judgment to render an opinion about subsurface conditions throughout the site. Actual subsurface conditions may diner -sometimes significantly from those indi- cated in your report. Retaining the geotechnical emineerwho developed your report to provide construction observation is the most effective method of managing the risks associated with unanticipated conditions. A Report's Recommendations Are Not Final Do not ove«ely on the construction recommendations included in your re- port Those recommendations are not final, because oeoiechnical engineers development principally from judomeni and opinion. Geotechnical engineers can finalize their recommendations only by observing actual subsurface conditions revealed during construction. The geotechnical eilm- neer who developed your report cannot assume responsibility or liability for the reports recommendations ii that engineer does not perbm construction observaton. A Geotechnical Engineering Report Is Subject to Misinterpretation Other design team members' misinterpretation of geotechnical engineer - no reports has resulted in cosily problems. Lower Ghat risk by having your geoiecbrrical engineer corder with appropriate me moats of the desla_rl ieam after subm'Itino the report. Also retain your geotechnical engineer to review peninegi elements of the design team's plans and specifications. Contractors can also misinterpret a geotechnical engineering report. Reduce that risk by having your geoiechnical engineer participate in piebid and preconsimcdoo conferences, and by providing construction observation. Do Not Redraw the Engineer's logs Geotechnical engineers prepare final boring and testing logs based upon their interpretation of field logs and laboraioiy data. To prevent errors or omissions, the loos included in a geotechnical engineering report should never be redrawn lot inclusion in architectural or other desian drawings. Only photographic of electronic feproducoon Is acceptable, not recognize that separating logs from the report can elevate risk. Give Contractors a Complete Report and Guidance Some owners arid design professionals mistakenly believe they can make contractors liable for un incipated subsurface conditions by limiting_ what they provide for old preparation. To help prevent costly problems, give con- Gaciors isle complete geoiechnical engineering report, but preface It with a clearly written letter oftrausmittal. In that letter, advise contractors that the sport was not prepared lot purposes of bid development and that the fepod's accuracy is limited, encourage them to confer vf1m the geotechnical engineer who prepared the report (a modest lee may be required) and/or to conductad- dltlonal study to obtain the specific Types of otormation they need or prefer. A pre'oid conference can also be valuable. Be sure contractors haveso'icient timelio oerlorm additional study Only then might you be in a position to give contractors the best information available to you, while requiring item to at least share some of the financial responsibilities stemming from unantici- pated conditions Read Responsibility Provisions Closely Some clients, design professionals, and contractors do not recognize that geotechnical engineering is far less exact than other engineering disciplines, This lack of understanding has created unrealistic expectations that have led to disappointments, claims, and disputes. To help reduce the risk of such outcomes, aeotechnical engineers commonly include a varieiyol explanatory provisions In their reports. Sometimes labeled "hr itatmgs" many of tress provisions indicate where geoiechnical engineers' responsibilities begin and end, to help others recognize their own responsibilities and risks. Read these orovisions closely. As:< questions. Your geotechnical engineer should respond lullyand irankly. Geoenvironmental Concerns Are Not Covered The equipment, techniques, and personnel used to periorm a geoeniriron- mental study diner significantly from those used to perform a geotechnical study. For that reason, a aeoiechgical engineering report does not usually re- late any geommonmental findings, conclusions, or recommendations. e.g , about the likelihood of encountering underground stofaae tanks or feaulaied contaminants. Unanticipated environmental problems have led to numerous project failures. If you have not yet obtained your own geoenvironmental in- formation, ask your geoiechnical consultant for risk management guidance. Do not rely on an environmental report prepared for someone else. Obtain Professional Assistance To Deal with Mold Diverse strategies can be applied during building design, construction, op- eration, and on, to prevent significant amounts of mold from orow- ing on indoorsurfaces. To be effective, all such siraieaies should be devised for the express purpose of on, prevention, integrated into a comprehensive plan, and executed with diligent oversight by a processional mold prevention consultant. Because just a small amount of water or moisture can lead b the development of severe mold infestations, a number of an, prevention strategies locus on keel building surfaces dry. While groundwraier, wa- fer infiltration, and similar issues may have been addressed as part of the geoiechnical engineering study whose findings are conveyed in-mis report, the geotechnical engineer in charge of this project is not a mold prevention consultant. none of the services performed in connection with the geotechnical engineer's study were designed or conducted for the purpose of mold prevention. Proper implementation of the recommendations conveyed in this report will not of itself he sufficient to prevent mold from growing in or on the struc- ture involved. Rely on Your ASFE-Member Geotechnical Engineer For Additional Assistance Membership in ASFE/The Best People on Earth exposes geoiechnical engi- neers to a wide array of risk management techniques that can be of Genuine benefit for everyone involved with a constmctlon project. Comer With your ASFE-member geotechnical engineer for more information. ASFE Ins Best Pe.Yle on E. IA 8811 Colesville Road/Suite G106, Silver Spring, MD 20910 Telephone:'301/565-2733 Facsimile:301/589-2017 e-mail: info@asfe.org wvvw.asie.org Copyright 2004 byASFE, Inc. Duplication, reproduction, or copying of this document, in whole or in part, by any means whalsoever, is strictly prohibited, except with ASFES specific written permission. Excerpting, quoting, or otherwise exhacling voicing from this document is permitted only with the express Ivritten permission of ASFE, and only for purposes of scholarly research or book review Only members of ASFE may use this document as a complement to or as an element cis geotechnical engineering report. Any other firm, individual, or proof entitythat so uses this document without being anASFEmember could be committing negligent or intentional (fraudulent) misrepresentation. IIGER06045.OM P v oil%11 ,/ !.. cl L.3+ Vj, '�✓- �,r "ter, �yy xf r'. t\ i .Y w� Pam 01 tl •� hr' VN aA. �(�tiit R• �' K" J� P ,,ii S ' �J •,�, . _ ft'• . t �. •� � _. s/ � � (I ��.,•- O Nan `�° �1: I , 1 A' f �'ti•�:,t�'ir ;".�� 1! {. ' tern ,�.i' i'`` ! f''i: j vi `r. • .� . "L Wiittet t ! j PSik IEEE r cs _J ... � \��_ ••rau ' J'j or �_1 •?�"l✓ram �i"r&/ i _� � f1� r. /i;. N f o (( i /�r"r�\l�/� hl�.i4V �Rt• (J mpg 1�r Vie.\ n ,1 11 t�. �k7 ` p h i .}� �/;� •� r```•,••�•,�i%1� �` f�f �' .'.'. 4� R�4 \� "'RSA h� ,.1 I 4,t. f �� � s�"'� (3jC;1� ` ��• 1)(ii/-�.�.. ��� � i �.}• /7 � (''' ,,_, _.,Copyng t02013.Nah(ina6O a hi c Soclef o- ubetl. NOTES' 1. USGS; 7.5 MINUTE, QUAD, "WILMINGTON', NORTH CAROLINA, 2016 NATIONAL GEOGRAPHIC SOCIETY 2. LAT 34.221610 N, LONG:-77.881085 W 0 1,000 2,000 ENVIRONME NTAL ASSESSMENT ®Feet Tj UNCW - PARKING LOT IMPROVEMENTS 1 inch = 2,000 feet PHASE 2 PARKING LOTS 2A213 DATE: 8/2812017 McADAMS FIGURE 1. USGS TOPOGRAPHIC VICINITY MAP JOB NO: UNW-17060 WILMINGTON, NEW HANOVER COUNTY, NORTH CAROLINA DRAWN BY buchholz X'.\Prolects\UNW\UNW-17060\Storm\Wetlantls\GIS\UNW17060_Figure 1 USGS.mxa, 8/28/201710:01'.16AM, buchholz FIGURE 4CONCEPTUAL SITE PLAN ! n� McAimms IV � „ � /re r ,\ •r6 \ 4�, t 4e C! 'low" •rvµ `JF wL ` \� Nl ILLUSTRATIVE MASTER PLAN FOR. UNCW, PARKING LOTS} WILMINGTON, NORTH CAROLINA WY, V�/ I I I- y r,n ' r `iO''L x neSv: ;3 ✓� r ',r":0 �t '.± ~*, AV r T � ri r y,,� � � f �' . t � 132 �}k+ P Lej ,Se �� s� , '; a ,• 'fir ��7 rE1+ Off' ice" v�jr r Ur �, �r�u"�' i fie r A,µ• a,`�; %{r"� x7n '' \ft, .�C y ' EA STC ;0 FV Ater h 'rdirAU{% �'� { r'' ,u�Y, � �. `'7' 5 : '; .✓.k' "r,'p, ,M ?Q +F, -r'Q. J Y f p, }Tfi.I!p.y,' "'% �d1t *} TO � Y T`� � t " y Nor "` .1t..,•+ r , ,, ✓ � ot. 1 yr��Pt1 x <' r, 4M C r,r•, rK arm v �T'., ( t 'r"}. ,p, yfYT;`T• d v "� et 'T r �'ri t { ;x G Y `v r4.,tj�Ey�J�+' �. t r r A � � 1 f z :�xr ,t f P�•y+e�l ,,'r . t 1 � 5 ,'� �'O'",v"1-tv%'�,1E' y t{"r SCg_^�'�' L, ,.3� rr J tr # vis�$� ,'�v ar + '�' s.Y�^J /�"� 7i � ... T ..-�.� }}.� f "rt fi I t .^y't r' F n tf• jjt1ayt ; t�j. s+t •lo . '; ,till •iN .'•r . �•,t 0 f : *� /n t,,.y r.> 'v it i 'rN tr .a45r -«`f f �i�' 1 1 s � > t ,�,:kn .� ems, d• d J r t ++ �,� 3 q Y� 4 e r l e �" I rVyr•x �r z`i,r {f.:�g>,,, r . yQK.'9t a .j(�. l,'-^ Alt yT'•�,ar tT,�"�"L'Y o X r 4das�'..;%t o•t « �-M o~:'"�Wy r'��"��`yy,^1� •�s`w $J�,`(rrr $ P.Fr�F tr F `#h''y '*� Rr'.y% $..e gin. �1'l."".t,F•T a� � 7y .1 ; r��kY � YA � � •... . � � � tuuP �+ Lf �tl".��./+xi'�}s Y a�.l �d „�+�� .^"'T •.Y+'.I aa�d t *•+ �j 4 ' i vlt � t � �k �a`Il�9 ar L�'�5 �r ��r,r;r ��.�.�+ � ��'�•t es�`tr.s �G �^�1 {,gr:•��� r%�?�� �r F ; '..•F'- � TO'��i vx�. !t�1 < i.,, tlge � x: ,"' ,��s'.4`i �r. � �� ix n � � w � `i 7 G;;• � C .. �.u2� s{$� ! '?. r ,, �+T•ro'� $ R4 l- e, prc.4x �a %ik C��� r➢� f� f Ct6. r 7 �+y: s ri tx} r t 1 1 . ��'� � .«r eE" 3�+ " "� i✓f.v sr �^r; f� �y I 1 "41X'i'@�}�g,fi? 5.+tuc��� \„ - rxt �,• �, J)�S�-'j t �" a ?i' :;'f fr'4'e5:S4 �'" r Lte¢^�'"?� t �;_ 1� � .. a5"w tre�v ix�r j 1Ry ,�c'C. q4' , WI►l er P rn, " i#ei..,at"x y FC.�e � p ,� t r n '° ,b, ,$�•y% ,,, °f hr, 1`�.;��+�Yf �� Jy�'ti.x2n"fi r•� (+r ��ypyR� �1 �,1gr�4y� s 9� y��� 4`* :TOen i�g u�� t h. 1 r�� }�Y f A�%�y~rt `L�td',,rt'��.. • ,.,ilt fi px.�Z e''*i 9a'}' j6 ""X,y" lku �r y, yRF;�eI .kyJ yq'.y�{4.y°jf-�.+j t +°'i s.�{� h' I ,,;�+s ja i� ��v^•'q y4 1'rM r. c •r�frk {q`_ f#} f +p,. Fill t,Ui z r• rys �p ` x +� zrk -.5+ V ..� n,w..R' tyy i x r;w7y t 4s f /"� iC 4 ° �• �+i� �ipt'��t� ,: ,,.. Y J5F 3F !�j 3 � �yry r � � ♦ i. , r,�t t.:t�r�r.. y, LYS � t Fyt���y;. � - t�. C r'. p�! ¢- r. .,... -hrf '�a1 ::� K '`'tTt$ °tr.... - < n'i3S:$ t ::'{. r.°�. .`� ,.7!!Il . "• NOTES' 1. USDA-SCS', SOIL SURVEY OF NEW HANOVER COUNTY, NORTH CAROLINA', SHEET 19 2. LAT. 34.221610 N, LONG:-77.881085 W 0 500 1,000 ENVIRONMENTAL ASSESSMENT Feet UNCW - PARKING LOT IMPROVEMENTS 1 inch= 1,000feet PHASE 2 PARKING LOTS 2A2B DATE 8/28/2017 WADAMS FIGURE 2. NRCS SOIL SURVEY JOB NO: UNW-17060 WILMINGTON, NEW HANOVER COUNTY, NORTH CAROLINA DRAWN BY: buchhclz X'.\Pmlects\UNVV\UNW-17060\Storm\Wetlanrls\GIS\UN W17060_Figure 2 Soils Map. mxd, 5128/2017 9;58'.07 AM, buchholz Yates, Kevin From: Capita, Rachel A CIV USARMY CESAW (US) <Rachel.A.Capito@usace.arrny.mil> Sent: Wednesday, October 04, 2017 8:12 AM To: Yates, Kevin Subject: RE: UNCW Parking lot improvements- site visit Hi Kevin, Sorry for they delayed response. Yes we were able to visit the site and verify your delineation. At this time the applicatior Unfortunately I have received multiple nationwide permits in the last couple of weeks that take priority over PJD and AJD out as soon as possible. Thanks, Rachel -----Original Message ----- From: Yates, Kevin [mailto:yates@mcadamsco.com) Sent: Tuesday, October 3, 2017 10:40 AM To: Capita, Rachel A CIV USARMY CESAW (US)<Rachel.A.Capito@usace.army.mil> Subject: [EXTERNAL] RE: UNCW Parking lot improvements -site visit Hey Rachel, Was wondering if you had a chance to go by this site at UNCW? Thanks, Kevin Kevin Yates I Senior Environmental Consultant, Water Resources McAdams 2905 Meridian Parkway, Durham, NC 27713 office 919. 361. 5000 x271 I direct 919. 287. 0895 1 mobile 919. 624. 6901 1 Blockedwww.mcadamsco.com I linkedin I twitter I instagram I join our team creating experiences through experience -----Original Message ----- From: Capita, Rachel A CIV USARMY CESAW (US)(mailto:Rachel.A.Capito@usace.army.mil) Sent: Tuesday, September 19, 2017 4:37 PM To: Yates, Kevin <yates@mcadamsco.com> Subject: RE: UNCW Parking lot improvements- site visit That's alright. I will have to check my calendar about next week, but it would most likely be in October. You do not need t check it out tomorrow as I have scheduled a couple of other appointments in the area. Just let me know if you would rath Thanks, Rachel -----Original Message ---- From: Yates, Kevin [mailto:yates@mcadamsco.com) Sent: Tuesday, September 19, 2017 4:33 PM To: Capita, Rachel A CIV USARMY CESAW (US)<Rachel.A.Capito@usace.army.mil> G ihiort fFYTFPAIAI I PP I IAIrAA/ Par imo Ini imnrnvo manic-6ft visit I would like to set up a time to meet onsite to verify your A1D request for the UNCW parking lot improvement project. An Wednesday September 20th around 1PM? Please let me know if this date and time will work for you and if not we will fin Thanks, Rachel Rachel Capito Regulatory Specialist U.S. Army Corps of Engineers Wilmington District Office: 910.251.4487 Cell: 910.899.6051 Weaver, Cameron From: Finch, Brandon <finch@mcadamsco.com> Sent: Friday, October 20, 2017 4:43 PM To: Weaver, Cameron Cc: Riggins, Daryl; Jamison, Galen Subject: [External] UNCW Hurst Lots - Erosion Control Express & Stormwater Scoping Meeting Request Attachments: 2017-10-20 UNW-17060 Request for Express Permit & SW Scoping Meeting.pdf; UNW17060_Figure 1 USGS.pdf; UNW17060_Figure 2 Soils Map.pdf; UNW17060_Figure 3 Existing Conditions.pdf; UNW17060 Figure 4 - Conceptual Site Plan.pdf; 2017-10-04 USACE - Rachel Capito email .pdf CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you verify that the attachment and content are safe. Send all suspicious email as an attachment to report.spam@nc.gov. Good afternoon Cameron, Thank you for taking my call earlier today. Please find attached our express request for this project, along with supporting documentation. As discussed, we would .like for the meeting to be an express review for erosion control (clearing & grubbing only) and the stormwater portion to be Scoping only. Please let me know if you have any questions or need any additional information. As always, thank you for your help! Brandon Finch j Director, Institutional McAdams 2905 Meridian Parkway, Durham, NC 27713 office 919. 361. 5000 x127'[ direct 919. 287. 0892 1 mobile 919. 210. 2912 1 finch(n)mcadamsco.com www.mcadamsco.com [ linkedin [ twitter [ instaaram [ join our team 1111 creating experiences through experience