Loading...
HomeMy WebLinkAboutSW8051217_HISTORICAL FILE_20070403STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 O15 1 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS L�l HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE 200-1 CUyo3 YYYYMMDD a IA TA [ J{or as � April 3, 2007 Eddie Anderson, Director of Facilities New Hanover County Schools 6410 Carolina Beach Road Wilmington, NC 28412 Subject: Approved Plan Revision Odgen Elementary School Stormwater Project No. SW8 051217 New Hanover County Dear Mr. Anderson: M ichacl F. Easley, Govemor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.G. Director Division of Water Quality On March 26, 2007, the Wilmington Regional Office received a plan revision for Stormwater Management Permit Number SW8 051217. The revisions include changes to the roof drain collection system. The changes do not affect the permitted drainage areas. It has been determined that a formal permit modification is not required for the proposed changes. We are forwarding you an approved copy of the revised plans for your files. Please replace the old approved plan sheet with the new one. Please be aware that all terms and conditions of the permit issued on February 13, 2006, remain in full force and effect. Please also understand that the approval of this revision to the approved plans for the subject State Stormwater Permit is done on a case -by -case basis. Any other changes to this project must be approved through this Office prior to construction. The issuance of this plan revision does not preclude the permittee from complying with all other applicable statutes, rules, regulations or ordinances which may have jurisdiction over the proposed activity, and obtaining a permit or approval prior to construction. If you have any questions concerning this matter, please do not hesitate to call me at (910) 796-7335. Sincerely, Linda Lewis Environmental Engineer III ENB\arl: S:\WQS\STORMWATER\PERMIT\051217PR.apr07 cc: Glenn Medlin, CLH Design Beth Wetherill, New Hanover County Engineering Tony Roberts, New Hanover County Building Inspections Linda Lewis CWilmington-Regional=Office Central Files N''ott���hCarolina Yalturnt/y North Carolina Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Phone (910) 796-7215 Customer Service Wilmington Regional Office IntemeC www.ncwateraualilv.ore Fax (910)350-2004 I-877-623-6748 An Equal Opportunity/Affirmative Action Employer — 50% Recycledl70% Post Consumer Paper CLH design, p.a. MeeGregor Perk, 125 Edinburgh South, Suite 310 Cmy, North Cet olive 27511 Phone: (919) 319-6716 Fex: (919) 319-7,516 Ezneib clhdesigaoclhdeslgnpe.com LETTER OF TRANSMITTAL 23-Mar-07 To: Linda Lewis- Application No. SW8 051217 Company: NCDENR Water Quality Section Address: 127 Cardinal Drive City, State Zip: Wilmington, NC 28405 Phone: (910) 796-7404 Fax: (910)350-2004 Method: UPS Ground Subject: Ogden Elementary School CLH Project Number: 1217 ® Prints ❑ Originals ❑ Specifications ❑ Applications ❑ Reports ❑ Copy of Letter ❑ Submittals ❑ Other: We are sending you the following items No. of Copies Date Description • 2 Revised courtyard area - full size Additional Remarks: Linda, Enclosed are the additional sheets as requested. FMAR Please call me at (919) 319-6716 if you have any questions. 2 6 2007 Thank you, i Signed J. Glenn Medlin cc: File 1217-Permit CLIP design, p.a. Mac6regor Farb; 125 Edinburgh South, Suite 310 Carx, North Carolina 27511 (hone: (919) 319-6716 Fax: (919) 319-7516 Email• clhdesignoclhdesignpa.com LETTER OF TRANSMITTAL To: Linda Lewis- Application No. SW8 051217 Company: NCDENR Water Quality Section Address: 127 Cardinal Drive City, State Zip: Wilmington, NC 28405 Phone: (910) 796-7404 Fax: (910)350-2004 22-Jan-07 Method: UPS Ground Subject: Ogden Elementary School CLH Project Number: 1217 E Prints ❑ Originals ❑ Specifications ❑ Applications ❑ Reports ❑ Copy of Letter ❑ Submittals ❑ Other: We are sending you the following items: No. of Copies Date Description 0 2 Revised courtyard area - full size 0 0 • • • Additional Remarks: Linda, Enclosed are the additional sheets as requested. There are no other sheets affected by these revisions. Please call me at (919) 319-6716 if you have any questions. Thank you, Signed �4 N rL- J. Glenn Medlin cc: File 1217-CAI RECEIVED JAN 2 3 2007 DWQ Re: Ogden ES Roof Drain Revision Status Subject: Re: Ogden ES Roof Drain Revision Status From: Linda Lewis <linda.lewis@ncmail.net> 0 1 v Date: Mon, 22 Jan 2007 08:26:23 -0500 To: Glenn Medlin <gmedlin@clhdesignpa.com> Glenn: Yes, I received the revised plan, and it appears that this is not a permit modification, but will require a plan revision. Please submit another copy of sheet C3.1 and two copies of any other plan sheets affected by these changes. The Division will review them and issue a "Plan Revision Approval Letter". Linda Glenn Medlin wrote: Linda, Good afternoon. I was on -site Monday and the Contractor was asking me about the status of the.roof drain revisions at Ogden ES. Did you receive the full size plan sheets? Where do we stand on that issue? Thank you again for your assistance with this matter questions, please feel free to call. Glenn Medlin **CLH Design P.A.** 125 Edinburgh South - Suite 310 Cary, NC 27511 Phone: 919.319.6716 Fax: 919.319.7516 If there are any gmedlin®clhdesignpa.com<mailto:gmedlin@clhdesignpa.com> I of 1 1/22/2007 8:26 AM Re: Ogden ES Stormwater Revisions e .-% Subject: Re: Ogden ES Stormwater Revisions From: Linda Lewis <linda.lewis@ncmail.net> Date: Thu, 04 Jan 2007 12:29:48 -0500 To: Glenn Medlin <gmedlin@clhdesignpa.com> Glenn: It's not so much the changes in the piping that are of concern, but 'rather, where all the runoff ends up. The stormwater permit requires all of that runoff to be directed into one of the permitted infiltration basins. If the proposed changes to the piping will alter the drainage areas for the infiltration basins, (i.e., how does the re-routing of the proposed drain leaders to daylight outside of the courtyard area affect their ultimate destination?) you will need to submit a permit modification. Please keep in mind that no runoff can bypass the permitted systems. I am unable to tell from the plan submitted if this is occurring or not. To be safe, please submit a full size drawing for comparison to the permitted plans so that I can make a more informed decision regarding the need for a modification or a plan revision. Linda Glenn Medlin wrote: Linda, I am working with Renee Scott on the Ogden ES project. The attached sketch shows potential revisions to the roof drain leaders and culvert pipe in the courtyard area. The original plans showed a larger culvert pipe and a few more roof drain outlets daylighting into the courtyard. This project is currently under construction and while the final grades are not achieved, yet, there have been some occurrances of standing water against the building in the courtyard area after heavy rainfalls. The Owner and Architect are concerned of the possibility of flooding the building during heavy rainfalls. In the proposed solution, we re-routed some roof drain leaders to daylight outside of the courtyard. This decreased the amount of water draining to the courtyard and allowed us to reduce the size of the culvert pipe. The reduction in pipe size allowed us to lower the grades above the pipe, which lowered the surface 'outlet' of the area, and hopefully will allow for better drainage away from the building. I understand that no storm pipes were permitted during the original design and that the culvert in question was discussed several times. Please review the proposed solution. If approved, we will issue bulletin drawing to the Contractor. Thank you for your assitance with this matter. If there are any questions, please feel free to call. Glenn Medlin *CLH Design P.A.* 125 Edinburgh South - Suite 310 Cary, NC 27511 Phone: 919.319.6716 Fax: 919.319.7516 gmedlin@clhdesignpa.com<mailto:gmedlin@clhdesignpa.com> 1 of 1 1/4/2007 12:38 PM 4\ FLUME 24 — 000 (2) 4'Lx3'Wxl2" 'A' STONE, SEE Fit v� for;Ilk 3� 1 - OUTLET PROTECTIO >: 4'Lx3'Wx12" CLASS 'A' STONE. SEE DE T 0.- / - ❑ SHEET C7. 1. 3 0 PROPOSED BUILDING FFE= 33.60' DRAINAGE STRUCTURE SCHEDULE STRUCTURE NO PIPE PIPE PIPE PIPE UPPER LONER UPSTREAM STRUCTURE DATA NOTES UP STRM ON SIRM SLOPE DIA MG_ MATRL INV. INV, TOP ELEV. DEPTH TYPE (SEE BELON) (IN) IF (ET) (TT) (PT) (I) (ET) A7 A2 0.3 UZI 30 ApVCO 31.10 37.00 - - FES B1 B2 0.667 18 736 Ap VCO 29.10 28.20 - - FES C1 C2 7.407 18 114 RCP 26.00 24.40 - - FES D1 02 0.709 15 86 A20C 27.60 27.00 _ 30.50 2.90 REVISE ROOF DRAIN CONNECTIONS AND GRADES AS INDICATED. SCALE 1"=40' Ogden Elementary School Replacement 3637 Meddl. SU RUC DEC St. X POST BID aAROC n W SLOPE AND BERM GRADE REVISION