HomeMy WebLinkAboutSW7081111_COMPLIANCE_20171005PERMIT NO.
STORMWATER DIVISION CODING SHEET
POST -CONSTRUCTION PERMITS
SW
DOC TYPE I ❑ CURRENT PERMIT
DOC DATE
❑ APPROVED PLANS
❑ HISTORICAL FILE
COMPLIANCE EVALUATION INSPECTION
120�
YYYYMMDD
Compliance Inspection Report
Permit: SW7081111 Effective: 05/13/09 Expiration: 12/30/21
Project: River's Edge at Elizabeth Crossing
Owner: River's Edge LLC
County: Pasquolank Adress: 1026 US Hwy 17 S
Region: Washington
City/State/Zip: Elizabeth Cry NC 27909
Contact Person: Traci Dusenbury Title: Phone: 919-662-0122
Directions to Project:
From the intersect of US 17 (business) and Halstead Ave INC 344) continue South along US 17 approx 0.5 miles to the merge
w/US 17 (bypass) It will be approx 1000' on the right.
Type of Project: State Stormwater - HD - Detention Pond
Drain Areas: 1 - (Knobbs Creek) (03-01-50) ( C;Sw)
On -Site Representative(s):
Related Permits:
Inspection Date: 1010512017 Entry Time: 02:30PM
Primary Inspector: William J Moore
Secondary Inspector(s):
Reason for Inspection: Routine
Permit Inspection Type: Slate Stormwater
Facility Status: ® Compliant ❑ Not Compliant
Question Areas:
® Slate Stormwater
(See attachment summary)
0
Exit Time: 03:00PM
Phone: 252-946-6481 Ext 264
Inspection Type: Compliance Evaluation
page. 1
Permit: SW7081111 Owner - Protect Rivers Edge LLC
Inspection Date: 10/05/2017 Inspection Type Compliance Evaluation
Reason for Visa: Routine
Inspection Summary:
Rivers Edge at Elizabeth Crossing located at 1026 US Hwy 17 Elilzabeth City, NC. Residential Apartment complex with
4.72 ac bua on 11.44 ac site. Protect appears to be constructed according to plans. PE Cart submitted 09/0112010 by
Sean Robey. Wet Pond constructed with surface area 47,439 sf; storage volume provided 144,039 cf & small dla orifice
2.5-inches. Generally, O&M very good, vegetation cut 2-3 inches (too close in some areas) but no significant erosion;
some small woody vegetation around inlets.
Built Upon Area
Yes
No NA NE
Is the site BUA constructed as per the permit and approval plans?
0
❑ ❑ ❑
Is the drainage area as per the permit and approved plans?
M
❑ ❑ ❑
Is the BUA (as permitted) graded such that the runoff drains to the system?
M
❑ ❑ ❑
Comment:
SW Measures Yes No NA NE
Are the SW measures constructed as per the approved plans? 0 ❑ ❑ ❑
Are the inlets located per the approved plans? 0 ❑ ❑ ❑
Are the outlet structures located per the approved plans? ❑ ❑ ❑
Comment:
Operation and Maintenance Yes No NA NE
Are the SW measures being maintained and operated as per the permit requirements? 0 ❑ ❑ ❑
Are the SW BMP inspection and maintenance records complete and available for review or provided to ❑ ❑ ❑
DWO upon request?
Comment: