Loading...
HomeMy WebLinkAboutNCC216307_Site Plan or Location Map_20211118I CAJJ, NIAUN & RtrvrvtUY, INU. tAF'HtJJLY HtAtHVtJ I It) UUIVIIVIUN LAW UUYYNIUM I ANU U I r1r_N I-NUF'tH I Y MUM It) IN I r'ItJt I -LAND. I r'ItJt I-LANJ AHt NU I Ill br- HtF'HU SYMBOLS AND ABBREVIATIONS ABC AGGREGATE BASE COURSE ALUM ALUMINUM AST2 ALUMINIZED STEEL - TYPE 2 B-B BACK TO BACK BOA BLOW -OFF ASSEMBLY C&G CURB AND GUTTER CFS CUBIC FEET PER SECOND CI CURB INLET CL CENTER LINE CMP CORRUGATED METAL PIPE CO CLEAN OUT COM COMMUNICATION CONC CONCRETE DCV DOUBLE CHECK VALVE DDCV DOUBLE DETECTOR CHECK VALVE DI DROP INLET DIP DUCTILE IRON PIPE EASE EASEMENT ELEC ELECTRIC EX EXISTING FES FLARED END SECTION FH FIRE HYDRANT FM FORCE MAIN FT FEET FT/SEC FEET PER SEC GALV GALVANIZED GV GATE VALVE HDPE HIGH DENSITY POLYETHYLENE L LENGTH LF LINEAR FEET MH MANHOLE PAVE PAVEMENT PE FINISHED PAD ELEVATION PP POWER POLE PVC POLYVINYL CHLORIDE R RADIUS R/W RIGHT-OF-WAY RED REDUCER RCP REINFORCED CONCRETE PIPE RPZ REDUCED PRESSURE ZONE SS SANITARY SEWER STA STATION TDD TEMPORARY DIVERSION DITCH TELE TELEPHONE TSB TEMPORARY SEDIMENT BASIN UG UNDERGROUND WCR WHEELCHAIR RAMP W/L WATER LINE WM WATER METER YI YARD INLET CONSTRUCTION NOTES M EXISTING CURB INLET ❑ EXISTING GRATE INLET/YARD INLET o EXISTING FLARED END SECTION -6- EXISTING FIRE HYDRANT oa-o EXISTING BLOW -OFF ASSEMBLY oa EXISTING GATE VALVE o EXISTING REDUCER ❑ EXISTING WATER METER OS EXISTING SAN SEWER MANHOLE o EXISTING CLEAN OUT ra EXISTING POWER POLE ❑ EXISTING TELEPHONE PEDESTAL EXISTING AREA LIGHT EXISTING SIGN NEW CURB INLET ■ NEW GRATE INLET/YARD INLET NEW FLARED END SECTION NEW FIRE HYDRANT �+ NEW BLOW -OFF ASSEMBLY H NEW GATE VALVE NEW REDUCER o NEW WATER METER 17, NEW TEE n NEW PLUG • NEW MANHOLE ® NEW CLEAN OUT T NEW SIGN o IRON PIPE BENCHMARK TEMP SILT FENCE U NANutU UN UUYItU IN ANY 1-UHIV1 UN IVIANNtH Wr1A I JUtVtH, NUN AHt I ntY Ill tit AJJIIaNCU Ill ANY INIHU I -AN I Y VVI I r1UU I NNZ) I Ub IAININU I r7t tAYHtJJtU VVHI I Ir-N F'tHIV11JJIUN ANU I:UNJtN I Ur CAJJ, NIAUN & RCNNCUY, INI:. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT TOWN OF KNIGHTDALE STANDARDS AND SPECIFICATIONS A TTENTION CONTRA CTORS The Construction Contractor responsible for the extension of water, sewer, and/or reuse, as approved in these plans, is responsible for contacting the Public Utilities Department at (919) 996-4540 at least twenty four hours prior to beginning any of their construction. Failure to notify both City Departments in advance of beginning construction, will result in the issuance of monetary fines, and require reinstallation of any water or sewer facilities not inspected as a result of this notification failure. Failure to call for Inspection, Install a Downstream Plug, have Permitted Plans on the Jobsite, or any other Violation of City of Raleigh Standards will result in a Fine and Possible Exclusion from future work in the City of Raleigh. NOTE: ALL CONSTRUCTION ACTIVITY MUST BE IN ACCORDANCE WITH THE ACCEPTED POLICIES OF THE TOWN OF KNIGHTDALE AND NCDOT EROSION CONTROL, STORMWATER AND FLOODPLAIN MANAGEMENT APPROVED EROSION CONTROL ❑ S- STORMWATER MGMT. ❑ S- FLOOD STUDY ❑ S- DATE 1PF 1PF TEMP TREE PROTECTION FENCE TPF M TEMP COMBINATION SILT/TREE PROTECTION FENCE 10 TEMP DIVERSION DITCH • • DISTURBED LIMITS .. .. STREAM - - G - - - G EXISTING GAS LINE - - coM - - - coM EXISTING COMMUNICATIONS LINE - - r - - - r EXISTING UNDERGROUND TELEPHONE - - E - - - E EXISTING UNDERGROUND ELECTRIC - - OHE - - - OHE EXISTING OVERHEAD ELECTRIC - - w - - - w EXISTING WATER LINE - - FM - - - FM EXISTING SANITARY SEWER FORCE MAIN - - ss - - - ss EXISTING SANITARY SEWER --------------- EXISTING STORM DRAINAGE NEW STORM DRAINAGE NEW WATER LINE NEW SANITARY SEWER FM NEW SANITARY SEWER FORCE MAIN FM G NEW GAS MAIN G • • • • • • • • • • • • • • • HANDICAPPED ACCESSIBLE ROUTE MUST �y014 (1L I TY X11)40, 14, _J UJ a m 7 0 BEFORE YOU DIG! CONTACT ONE -CALL CENTER 1-800-632-4949 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH APPLICABLE MUNICIPALITY STANDARDS, SPECIFICATIONS, AND DETAILS. WORK IN THIS PROJECT SHALL ALSO CONFORM TO THESE PLANS, THE LATEST EDITIONS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION (NCDOT) ROAD AND BRIDGE SPECIFICATIONS, THE ROAD AND BRIDGE STANDARDS, THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL HANDBOOK, THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL REGULATIONS, THE FINAL GEOTECHNICAL REPORT, AND GENERAL DESIGN STANDARDS. IN THE EVENT OF CONFLICT BETWEEN ANY OF THESE STANDARDS, SPECIFICATIONS, OR PLANS, THE MOST STRINGENT SHALL GOVERN. 2. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR TRENCH SAFETY DURING ALL PHASES OF CONSTRUCTION. 3. THE LOCATION AND SIZE OF EXISTING UTILITIES AS SHOWN IS APPROXIMATE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR HORIZONTALLY AND VERTICALLY LOCATING AND PROTECTING ALL PUBLIC OR PRIVATE UTILITIES WHICH LIE IN OR ADJACENT TO THE CONSTRUCTION SITE. AT LEAST 48 HOURS PRIOR TO ANY DEMOLITION, GRADING, OR CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALL NOTIFY THE NORTH CAROLINA ONE -CALL UTILITIES LOCATION SERVICE (ULOCO) AT 1-800-632-4949 FOR PROPER IDENTIFICATION OF EXISTING UTILITIES WITHIN THE SITE. 4. THE CONTRACTOR SHALL SALVAGE AND PROTECT ALL EXISTING POWER POLES, SIGNS, MANHOLES, TELEPHONE RISERS, WATER VALVES, ETC. DURING ALL CONSTRUCTION PHASES. THE CONTRACTOR SHALL REPAIR, AT HIS OWN EXPENSE, ANY EXISTING UTILITIES DAMAGED DURING CONSTRUCTION. 5. TRAFFIC CONTROL ON PUBLIC STREETS SHALL BE IN CONFORMANCE WITH THE TRAFFIC CONTROL PLAN, THE "MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES," AND AS FURTHER DIRECTED BY CITY AND STATE INSPECTORS. 6. ANY DISCREPANCIES FOUND BETWEEN THE DRAWINGS AND SPECIFICATIONS AND SITE CONDITIONS OR ANY INCONSISTENCIES OR AMBIGUITIES IN DRAWINGS OR SPECIFICATIONS SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER, IN WRITING, WHO SHALL PROMPTLY ADDRESS SUCH INCONSISTENCIES OR AMBIGUITIES. WORK DONE BY THE CONTRACTOR AFTER HIS DISCOVERY OF SUCH DISCREPANCIES, INCONSISTENCIES, OR AMBIGUITIES SHALL BE DONE AT THE CONTRACTOR'S RISK. 7. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR SHALL ARRANGE THE MEETING WITH THE CITY ENGINEERING DIVISION. 8. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL REQUIRED PERMITS AND APPROVALS PRIOR TO COMMENCING CONSTRUCTION. 9. ALL AREAS SHALL BE GRADED FOR POSITIVE DRAINAGE, AND AS SHOWN ON THESE PLANS. THE CONTRACTOR SHALL MAINTAIN ADEQUATE SITE DRAINAGE DURING ALL PHASES OF CONSTRUCTION. THE CONTRACTOR SHALL USE SILT FENCES (OR OTHER METHODS APPROVED BY THE ENGINEER AND APPLICABLE MUNICIPALITY) AS REQUIRED TO PREVENT SILT AND CONSTRUCTION DEBRIS FROM FLOWING ONTO ADJACENT PROPERTIES. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE, OR LOCAL EROSION, CONSERVATION, AND SILTATION ORDINANCES. CONTRACTOR SHALL REMOVE ALL TEMPORARY EROSION CONTROL DEVICES UPON COMPLETION OF PERMANENT DRAINAGE FACILITIES AND THE ESTABLISHMENT OF A STAND OF GRASS OR OTHER GROWTH TO PREVENT EROSION. 10. THE CONTRACTOR SHALL CLEAR AND GRUB THE SITE AND PLACE, COMPACT, AND MOISTURE CONDITION ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEER'S SPECIFICATIONS. THE FILL MATERIAL TO BE USED SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. 11. MATERIALS USED TO CONSTRUCT EMBANKMENTS FOR ANY PURPOSE, BACKFlLL AROUND DRAINAGE STRUCTURES, OR IN UTILITY TRENCHES FOR ANY OTHER DEPRESSION REQUIRING FILL OR BACKFlLL SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST AS SET OUT IN ASTM STANDARD D698. STONE BACKFlLL SHALL BE COMPACTED TO 95% MAXIMUM DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST AS SET OUT IN ASTM STANDARD D1557. THE CONTRACTOR SHALL, PRIOR TO ANY OPERATIONS INVOLVING FILLING OR BACKFILLING, SUBMIT THE RESULTS OF THE PROCTOR TEST TOGETHER WITH A CERTIFICATION THAT THE SOIL TESTED IS REPRESENTATIVE OF THE MATERIALS TO BE USED ON THE PROJECT. TESTS SHALL BE CONDUCTED BY A CERTIFIED MATERIALS TESTING LABORATORY AND THE CERTIFICATIONS MADE BY A LICENSED PROFESSIONAL ENGINEER REPRESENTING THE LABORATORY. ENVIRONMENTAL CONSULTANT SIGNATURE VILLAGE GATE S. SMITHFIELD ROAD TOWN OF KNIGHTDALE, WAKE COUNTY, NORTH CAROLINA WATER ALLOCATION POLICY BONUS POINT CHART Points Base Points - Major Residential Subdivision 15 Bonus Point Items (Additional 35 Points required) Open Space > 2 acres 2 Stormwater Wet Pond w/Fountain 4 Residential Architectural Standards 15 Outdoor Enhancement (Public Art) 4 Outdoor Deck/Patio > 1,000 sf 1 Pool Amenities (Jacuzzi/Hot Tub/Whirlpool) 2 Clubhouse (Full Kitchen & less than 4,000 sf meeting space) 9 Total Proposed Bonus Points: 37 Total Points (50 Points Required) 52 12. PROPOSED CONTOURS AND GUTTER GRADIENTS ARE APPROXIMATE. PROPOSED SPOT ELEVATIONS AND ROADWAY PROFILES/SUPERELEVATIONS ARE TO BE USED IN CASE OF DISCREPANCY. 13. THE CONTRACTOR SHALL REVIEW, VERIFY AND COORDINATE ALL DIMENSIONS SHOWN ON PLANS, INCLUDING THE HORIZONTAL AND VERTICAL LOCATION OF CURB INLETS AND GRATE INLETS AND ALL UTILITIES CROSSING THE STORM SEWER PRIOR TO STARTING PROJECT. 14. ALL CURB JOINTS SHALL EXTEND THROUGH THE CURB. MINIMUM LENGTH OF OFFSET JOINTS AT RADIUS POINTS IS 1.5 FEET. ALL JOINTS SHALL BE SEALED WITH JOINT SEALANT. 15. ALL HANDICAP RAMPING, STRIPING, AND PAVEMENT MARKINGS SHALL CONFORM TO ADA REQUIREMENTS AND THE "NORTH CAROLINA STATE BUILDING CODE, VOL. 1-C ACCESSIBILITY CODE. 16. OWNER SHALL PROVIDE FENCING AND OTHER SAFETY MEASURES NECESSARY IN AND AROUND ANY PROPOSED STORMWATER MANAGEMENT MEASURES (PONDS, WETLANDS, ETC.) OBTAINING PROPER PERMITS SHALL BE THE RESPONSIBILITY OF THE OWNER. 17. RETAINING WALLS EXCEEDING 30 INCHES IN HEIGHT SHALL INCLUDE FALL PROTECTION IN THE FORM OF A HANDRAIL OR FENCING ON THE HIGH SIDE OF THE RETAINING WALL AND WILL REQUIRE A SEPARATE BUILDING PERMIT. 18. PROPER COMPACTION OF ALL FILL SOILS PLACED ON SITE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. COMPACTION SHALL BE ADEQUATE TO SUPPORT THE PROPOSED USE OF AREAS IN WHICH FILL SOILS ARE PLACED. THE CONTRACTOR SHALL HIRE A GEOTECHNICAL ENGINEER TO TEST AND VERIFY THAT COMPACTION IS ADEQUATE FOR THE PROPOSED USE OF IN THE AREA OF FILL PLACEMENT. 19. ALL ASPECTS OF THIS PROJECT SHALL BE IN FULL COMPLIANCE WITH CURRENT ADA STANDARDS. IF THE CONTRACTOR NOTES ANY ASPECTS OF THE PROJECT WHICH ARE NOT IN COMPLIANCE, THE ENGINEER SHALL BE NOTIFIED PRIOR TO ANY FURTHER WORK BEING PERFORMED. ANY WORK PERFORMED AFTER THE CONTRACTOR NOTES SUCH A NON COMPLIANCE IS SUBJECT TO REMOVAL AND REPAIR AT THE CONTRACTOR'S EXPENSE. 20. THE CONTRACTOR OR OWNER SHALL EMPLOY A GEOTECHNICAL ENGINEER TO TEST ALL EMBANKMENTS AND FILL PLACEMENT FOR PROPER COMPACTION. PROPER COMPACTION SHALL BE PER THE GEOTECHNICAL ENGINEER'S RECOMMENDATIONS OR THESE PLANS, WHICHEVER IS MORE STRINGENT. EMBANKMENTS FOR PONDS SHALL BE PLACED IN 6 INCH LOOSE LAYERS AND SHALL BE COMPACTED TO A DENSITY OF NO LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DENSITY AT A MOISTURE CONTENT OF + OR - TWO PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM D698. THE CONTRACTOR SHALL TAKE PHOTOGRAPHS OF THE OUTLET STRUCTURE AT ALL AT ALL PHASES OF INSTALLATION AND SHALL RETAIN WITH GEOTECHNICAL TESTING DATA. THE CONTRACTOR SHALL ALSO RETAIN ALL SHIPPING RECORDS AND SPECIFICATIONS FOR THE OUTLET STRUCTURE MATERIALS AND STRUCTURES. ALL OF THE ABOVE DATA MAY BE REQUIRED AS PART OF THE MUNICIPALITY AS -BUILT PROCESS AND SHALL BE MADE AVAILABLE TO THE ENGINEER UPON REQUEST. THE CONTRACTOR AND OWNER SHALL HAVE DOCUMENTATION OF THESE TESTS AVAILABLE UPON REQUEST. 21. RETAINING WALLS SHOWN HEREIN SHALL BE DESIGNED BY A QUALIFIED PROFESSIONAL ENGINEER WITH EXPERIENCE DESIGNING RETAINING WALLS. AT LEAST 14 DAYS PRIOR TO BEGINNING CONSTRUCTION OF RETAINING WALLS, THE CONTRACTOR SHALL CONTACT THE OWNER'S GEOTECHNICAL ENGINEER TO SCHEDULE AND COORDINATE ALL APPROPRIATE INSPECTIONS, TESTING, AND VERIFICATION NECESSARY DURING RETAINING WALL CONSTRUCTION. THE GEOTECHNICAL ENGINEER SHALL PROVIDE CONTINUOUS INSPECTION TESTING AND VERIFICATION FOR THE DURATION OF RETAINING WALL CONSTRUCTION. PROPER SCHEDULING, EXECUTION, AND RECORD KEEPING FOR ALL REQUIRED INSPECTIONS, TESTING, AND VERIFICATION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. SUCH RECORDS SHALL BE RETAINED AND SHALL BE PROVIDED TO THE OWNER AND BASS, NIXON & KENNEDY, INC. ALL MONITORING, TESTING, AND VERIFICATION SHALL CONFORM TO THE MOST RECENT VERSION OF THE NC BUILDING CODE CHAPTER 18, SECTION 1806 OR THE WALL DESIGN ENGINEER'S SPECIFICATIONS, WHICHEVER IS MORE STRINGENT. EROSION CONTROL SUBMITTAL TOWN OF KNIGHTDALE PUD CASE NO. ZMA=1=21 OWNER: VILLAGE GATE AT KNIGHTDALE, LLC 8480 HONEYCUTT RD. STE 200 RALEIGH, NC 27615 GIOVANNI MORTARINA TRUSTEE 2830 CHARLEMAGNE DR. VIRGINIA BEACH, VA 23451-1358 BILLY B. ROBERSON 1213 INDIAN TRAIL DR. RALEIGH NC 27609-5439 ENGINELYR: 0� DEVELOPER: KDM DEVELOPMENT CORPORATION 1080 PITTFORD VICTOR RD P I TTS FO R D, NC 14534 CONTACT: KENYON BURNHAM PHONE: (585) 465-0099 EMAIL: kburnha@u.rochester.edu HCA 4 V_ FE ss/ / Q- Q SEA Y D g\ va BASS, NIXON & KENNEDY, INC. 11/05/21 CONSULTING ENGINEERS 6310 CHAPEL HILL ROAD, SUITE 250 RALEIGH, NORTH CAROLINA 27607 TELEPHONE: (919) 851-4422 FAX: (919) 851-8968 CERTIFICATION NUMBERS: NCBELS (C-0110) NCBOLA C-0267 CONTACT: MARTY D. BIZZELL, PE, CPESC EMAIL: Marty.Bizzell@BNKinc.com SITE DATA SHEET INDEX PROJECT NAME: VILLAGE GATE COVER CO.2 OVERALL EXISTING CONDITIONS PLAN PIN / REAL ID NUMBER (LOT 1): 1753-67-6372 / 0483732 Co.3 ENLARGED DEMOLITION PLAN - WEST PIN / REAL ID NUMBER (LOT 2): 1753-77-8199 / 0010040 CO.4 ENLARGED DEMOLITION PLAN - NORTHWEST PIN / REAL ID NUMBER (LOT 3): 1753-87-9748 / 0282557 CO.5 ENLARGED DEMOLITION PLAN - SOUTHWEST CO.6 ENLARGED DEMOLITION PLAN - NORTHEAST ADDRESS (LOT 1): 0 S SMITH FIELD ROAD CO.7 ENLARGED DEMOLITION PLAN - SOUTHEAST KNIGHTDALE, NORTH CAROLINA C1.0 OVERALL SITE PLAN C1.1 ENLARGED SITE PLAN - WEST ADDRESS (LOTS 2 & 3): 0 MAILMAN ROAD C1.2 ENLARGED SITE PLAN - NORTHWEST KNIGHTDALE, NORTH CAROLINA C1.3 ENLARGED SITE PLAN - SOUTHWEST ZONING: C1.4 ENLARGED SITE PLAN - NORTHEAST EXISTING: RT C1.5 ENLARGED SITE PLAN - SOUTHEAST PROPOSED: PUD C6.0 OVERALL STAGE 1 EROSION CONTROL PLAN C6.1 ENLARGED STAGE 1 EROSION CONTROL PLAN - WEST USE: C6.2 ENLARGED STAGE 1 EROSION CONTROL PLAN - NORTHWEST EXISTING: VACANT C6.3 ENLARGED STAGE 1 EROSION CONTROL PLAN - SOUTHWEST PROPOSED: VACANT C6.4 ENLARGED STAGE 1 EROSION CONTROL PLAN - NORTHEAST C6.5 ENLARGED STAGE 1 EROSION CONTROL PLAN - SOUTHEAST SITE AREA (GROSS): (RECOMBINATION REQ'D) C6.6 OVERALL STAGE 2 EROSION CONTROL PLAN 1753-67-3147 (LOT 1): 24.28 AC (1,057,690 SF) C6.7 ENLARGED STAGE 2 EROSION CONTROL PLAN - WEST 1753-77-8199 (LOT 2): 36.02 AC (1,568,983 SF) 1753-87-9748 3): 15.56 AC SF) C6.8 ENLARGED STAGE 2 EROSION CONTROL PLAN - NORTHWEST (LOT TOTAL: (677,684 75.86 AC (3,304,357 SF) C6.9 ENLARGED STAGE 2 EROSION CONTROL PLAN -SOUTHWEST C6.10 ENLARGED STAGE 2 EROSION CONTROL PLAN - NORTHEAST DEDICATED R/W AREA (ONSITE): C6.11 ENLARGED STAGE 2 EROSION CONTROL PLAN - SOUTHEAST S. SMITHFIELD ROAD: 0.35 AC (15,414 SF) C6.12 NCGO1 PLAN MAILMAN ROAD: 0.40 AC (17,537 SF) C6.13 EROSION CONTROL DETAILS TOTAL ONSITE: 0.76 AC (32,951 SF) C6.14 EROSION CONTROL DETAILS NET SITE AREA: 75.10 AC (3,271,406 SF) SITE PERMITTING APPROVAL Water and Sewer Permits (if applicable) The Cityof Raleigh consents to the connection and extension of the City's Public Sewer System as shown on this Ian. The g th+ Y P material and Construction methods used forthis project shall conform tothe standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit# The City of Raleigh consents to the connection and extension of the City's Public Water System as shown on this plan. The material and Construction methods used forthis project shall conform tothe standards and specifcationsof the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # - The City of Raleigh consents to the connection to its public sewer system and extension of the private sewer collection system as shown on this plan. The material and constructions methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # - - CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Electronic Approval: This approval is being issued electronically. This approval is valid only upon the signature of a City of Raleigh Review Officer below. The City will retain a copy of the approved plans. Any work authorized by this approval must proceed in accordance with the plans kept on file with the City. This electronic approval may not be edited once issued. Any modification to this approval once issued will invalidate this approval. City of Raleigh Development Approval Raleigh Water Review Officer a. Town Certification. This design has been reviewed by the Engineer for the Town of Knightdale, and to the best of my knowledge and belief, it conforms to the requirements established in the Standard Specifications of the Town of Knightdale. By: Date: Town Engineer These plans are approved by the Town of Knightdale and serve as construction plans for this project. p p 1 By: Date: Administrator a. Town Approved Standards Shall Control. In the event of a conflict or inconsistency between these construction drawings and the Town of Knightdale's Approved Standards for this project, the Approved Standards shall control. Town of Knightdale Approved Standards shall mean all development documents necessary for approval for the Property including, but not limited to, any special use permit, subdivision plan, site plan, subdivision plat(s), phasing schedule, Development Agreement, Utility Allocation Agreement, Annexation Agreement, the Town of Knightdale Standard Specification and Details Manual and applicable provisions of the North Carolina State Building Code. b. Professional Design Engineer Certification. These improvements shall be constructed in accordance with the following drawings and with the Standard Specifications of the Town of Knightdale. I PE, certifythat the Standard Specifications of the I' Town of Knightdale have been thoroughly checked and found to be applicable to this project. All exceptions to the applicable Town standards have been previously approved by the Town of Knightdale and said exceptions are shown on Sheet(s) of these drawings. Seal By: , PE Date: T N T 1 CQ G N 0 Z W Q U a O Z F_ U LU a W J Q 0 F_ 0 Z LL O Z O F_ U Z 0 W Z Z W Y Ca Z O X Z Cl) Q m z cc 0 Z O cc H Z U W H Q 0 W 0Q J J_ ti O O O N 6 0