HomeMy WebLinkAboutSW6210906_Design Calculations (Riprap)_20211014 OUTLET PROTECTION DATEDESIGN PHASE DESIGN 7-21-21PRELIM/ / PROJECT NAMEPROJECT NOCONSTR/ X / Brooke Valley Subdivision1781REVISION/ / LOCATIONBYRECORD/ / Hoke County, North CarolinaCEKOTHER/ / CHECKED BY(SPECIFY) CSB Storm Outlet Structure 10/Qfull = FES No.=FES-2Q0.71 Pipe Dia=18 inV/Vfull = 1.08 Q 10=4.37 cfsV =3.8fps Qfull =6.16 cfs Vfull = 3.48 fps From Fig. 8.06.b.1:Zone=2 D 50 From Fig. 8.06.b.2:=8 in D MAX =12 in Riprap Class=B Apron Thickness=18 in Apron Length=9.0 ft Apron Width @ Outlet=4.5 ft Apron Width @ End=10.5 ft Storm Outlet Structure FES No.=FES-4Q 10/Qfull =0.30 Pipe Dia=18 inV/Vfull = 0.87 Q 10=4.24 cfsV =6.9fps Qfull =13.90 cfs Vfull =7.85 fps From Fig. 8.06.b.1:Zone=2 From Fig. 8.06.b.2:D 50=8 in D MAX=12 in Riprap Class=B Apron Thickness=18 in Apron Length=9.0 ft Apron Width @ Outlet=4.5 ft Apron Width @ End=10.5 ft 1781-Storm Drainage for Spread.xlsLATEST REVISION: 10/14/2021 1:28 PMPAGE 1 OF 3 OUTLET PROTECTION DATEDESIGN PHASE DESIGN 7-21-21PRELIM/ / PROJECT NAMEPROJECT NOCONSTR/ X / Brooke Valley Subdivision1781REVISION/ / LOCATIONBYRECORD/ / Hoke County, North CarolinaCEKOTHER/ / CHECKED BY(SPECIFY) CSB Storm Outlet Structure Q 10/Qfull =0.62 FES No.=FES-6 Pipe Dia=18 inV/Vfull = 1.05 Q 10=7.56 cfsV =7.2fps Qfull =12.18 cfs Vfull = 6.88 fps From Fig. 8.06.b.1:Zone=2 From Fig. 8.06.b.2:D 50=8 in D MAX=12 in Riprap Class=B Apron Thickness=18 in Apron Length=9.0 ft Apron Width @ Outlet=4.5 ft Apron Width @ End=10.5 ft Storm Outlet Structure 10/Qfull = FES No.=FES-8Q0.26 Pipe Dia=18 inV/Vfull = 0.83 Q 10= 7.93 cfsV =14.5fps Qfull =30.90 cfs Vfull =17.46 fps From Fig. 8.06.b.1:Zone=2 50 From Fig. 8.06.b.2:D=8 in D MAX =12 in Riprap Class=B Apron Thickness=18 in Apron Length=9.0 ft Apron Width @ Outlet=4.5 ft Apron Width @ End=10.5 ft 1781-Storm Drainage for Spread.xlsLATEST REVISION: 10/14/2021 1:28 PMPAGE 2 OF 3 OUTLET PROTECTION DATEDESIGN PHASE DESIGN 7-21-21PRELIM/ / PROJECT NAMEPROJECT NOCONSTR/ X / Brooke Valley Subdivision1781REVISION/ / LOCATIONBYRECORD/ / Hoke County, North CarolinaCEKOTHER/ / CHECKED BY(SPECIFY) CSB Storm Outlet Structure FES No.=SKIMMERQ 10/Qfull =1.00 Pipe Dia=2 inV/Vfull = 1.14 Q 10=0.07 cfsV =3.7fps Qfull =0.07 cfs Vfull = 3.21 fps From Fig. 8.06.b.1:Zone=1 From Fig. 8.06.b.2:D 50=4 in D MAX=6 in Riprap Class=A Apron Thickness=9 in Apron Length=0.7 ft Apron Width @ Outlet=0.5 ft Apron Width @ End=0.8 ft 1781-Storm Drainage for Spread.xlsLATEST REVISION: 10/14/2021 1:28 PMPAGE 3 OF 3