Loading...
HomeMy WebLinkAboutSW7970820_HISTORICAL FILE_20201019STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW j�(`o2P"j DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD PV'J t4'0 ROY COOPER Governor MICHAEL S. REGAN Secretary BRIAN WRENN Director NORTH CAROLINA Environmental Quality October 19. 2020 Quail Run Business Center, LLC Attention: Mr. Michael Davenport, Manager 406 W. Lake Drive Kill Devil Hills, NC 27948 Subject: Stormwater Permit No. SW7970820 Renewal Quail Run Business Center High Density Project Dare County Dear Mr. Davenport: The Washington Regional Office received a Stormwater Management Permit Application for renewal of the subject permit on September 21, 2020. Staff review of the applications have determined that the permit can be reissued. We are forwarding Permit No. SW7970820 dated October 19, 2020, for the continued operation of the subject project. This permit, upon its effective date, will replace all previous State Stormwater permits for this project. This permit shall be effective from January 27, 2021 until January 26, 2029 and shall be subject to the conditions and limitations as specified therein, and does not supersede any other agency permit that may be required. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact me at (252) 948-3923, Sincerely, t'7 Roger K. Thorpe Environmental Engineer North Carolina Department of Environmental Quality 1 Division of Energy, Mineral and Land Resources �� Washington Regional Office ':. 043 Washington Square Mall I Washington. North Carolina II889 :y STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules and Regulations PERMISSION IS HEREBY GRANTED TO Quail Run Business Center, LLC Quail Run Business Center Located at 500 Sand Dune Drive, Kitty Hawk, NC Dare County FOR THE construction, operation and maintenance of an infiltration basin in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Energy, Mineral, and Land Resources (Division) and considered a part of this permit. This permit shall be effective from January 27, 2021 until January 26, 2029, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 2 of this permit, the Project Data Sheet. 3. A maximum of 1.03 acres of built upon area is allowed. 4. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with approved plans. 5. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. PROJECT DATA Project Name: Quail Run Business Center Permit Number: SV 7970820 Location: Dare County Applicant: Quail Run Business Center, LLC Receiving Stream: UT Kitty Hawk Bay Classification of Water Body: SC Total Site Area: 1.71 ac Drainage area: 1.71 ac Total Impervious allowed: 1.03 sf Required Storage Volume: 5,615 cf Provided Storage Volume: 13,776 cf Overflow Elevation: 16.0 ft 6. No homeowner/lot owner/developer shall be allowed to fill in, alter, or pipe any vegetative practices (such as swales) shown on the approved plans as part of the stormwater management system without submitting a revision to the permit and receiving approval from the Division. 7. The following items will require a modification to the permit: a. Any revision to the approved plans, regardless of size b. Project name change C. Transfer of ownership d. Redesign or addition to the approved amount of built -upon area e. Further subdivision of the project area. In addition, the Director may determine that other revisions to the project should require a modification to the permit. 8. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. II. SCHEDULE OF COMPLIANCE 1. The permittee will comply with the following schedule for construction and maintenance of the stormwater management system. a. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surfaces except roads. b. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 2. The facilities must be properly maintained and operated at all times. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency including, but not limited to: a. Semiannual scheduled inspections (every 6 months) b. Sediment removal ./ C. Mowing and revegetation of side slopes d. Immediate repair of eroded areas e. Maintenance of side slopes in accordance with approved plans and specifications f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of the Division. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 6. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Mail the Certification to the Washington Regional Office, 943 Washington Square Mall, Washington, North Carolina, 27889, attention Division of Energy, Mineral, and Land Resources. 7. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. f II�e�: f�LLSI�l.I ]�L�I,I`9 1. This permit is not transferable. In the event there is a desire for the facilities to change ownership,.or there is a name change of the Permittee, a formal permit request must be submitted to the Division accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division, in accordance with North Carolina General Statute 143-215.6(a) to 143-215.6(c). 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. 6. This permit shall be effective from January 27, 2021 until January 26, 2029. The Permittee, at least six (6) months prior to the expiration of this permit, shall submit in writing a request for an extension along with appropriate application fee. Permit issued this the 19th day of October 2020 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION For Brian Wrenn, Director Division of Energy, Mineral and Land Resources . By Authority of the Environmental Management Commission Permit Number SW7970820 ROY COOPER Governor MICHAELS.REGAN Secretary BRIAN WRENN Director NORTH CAROLINA Environmental Quality July 23, 2020 Quail Run Business Center, LLC Attention: Michael Davenport, Managing Member 406 W. Lake Drive Kill Devil Hills, NC 27948 Subject: Stormwater Permit Renewal Stormwater Management Permit SW7970820 Quail Run Business Center Dare County Dear Mr. Davenport: A Division of Energy, Mineral, and Land Resources file review has determined that Stormwater Permit SW7970820 for a stormwater treatment system consisting of an infiltration basin serving the Quail Run Business Center located at 500 Sand Dune Drive, Kitty Hawk, NC expires on January 26, 2021. This is a reminder that permit renewal applications are due 180 days prior to expiration. We do not have a record of receiving a renewal application. Please submit a completed permit renewal application along with a $505.00 fee for permit renewal. Permit application forms for renewal can be found on our website at: https•//deq nc gov/about/divisions/energy-mineral-land-resources/energy-mineral-land- rules/stormwater-oroeram/post-construction. North Carolina General Statutes and the Coastal Stormwater rules require that this property be covered under a stormwater permit. Failure to maintain a permit subjects the owner to assessment of civil penalties If you have questions, please feel free to contact me at (252) 948-3923. 1 will be glad to discuss this by phone or meet with you. If you would like, I can e-mail you a copy of the application form. You can request a copy by e-mailing me at roger.thorpe(a)ncdenr.gov. Sincerely, Rog r K. Thorpe Environmental Engineer North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources Washington Regional Office 1 943 Washington Square Mall I Washington, North Carolina 27889 252.946.6481 ROY COOPER Governor MICHAEL S. REGAN Secretary BRIAN WRENN Director Z i m NORTH CAROLINA EhI&Vmnffl&W Qudky July 23„2020 , Quail Run Business Center, LLC Attention: Michael Davenport, Managing Member 406 W. Lake Drive Kill Devil Hills, NC 27948 Subject: Stormwater Permit Renewal Stormwater Management Permit SW7970820 Quail Run Business Center Dare County Dear Mr. Davenport: A Division of Energy,- Mineral, and Land Resources file review has determined that Stormwater Permit SV 7970820 for a stormwater treatment system consisting of an infiltration basin serving the Quail Run Business Center located at 500 Sand Dune Drive, Kitty Hawk, NC expires on January 26, 2021. This is a reminder that permit renewal applications are due 180 days prior to expiration. We do not have a record of receiving a renewal application. Please submit a completed permit renewal application along with a $505.00 fee for permit renewal. Permit application forms for renewal can be found on'our website at: https. /aeq,nc.goc/a _bout/diiisions/energy mineral land-resoutces/en _rEy-mineral_-land_ r 11 s/stormwater-program/poct-construction. North Carolina General Statutes and the Coastal Stormwater rules require that this property be covered under a stormwater permit. Failure to maintain a permit subjects the owner to assessment of civil penalties. If you have questions, please feel free to contact me at (252) 948-3923. I will be glad to discuss this by phone or meet with you. if you would like, I can e-mail you a copy of the application form. You can request a copy by e-mailing me at roger thorpe(a)ncdenr.00v. Sincerely, Rog r K. Thorpe Environmental Engineer D�FQ� North Caroline Department of Envittxanental Q"Ilty I Division of Energy, Mineral and Land Resources Washington Rcgionel Offim 1 943 Washington Squaie Mail I Washington, North Caroiima 27889 252.946.6481 V)/,-m rTF Michael F. Easley, Governor W William G. Ross Jr-, Secretary �J r North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality January 26, 2007 Mr. Michael Davenport, Member Quail Run Business Center, LLC 406 W. Lake Drive Kill Devil Hills, NC 27948 Subject: Permit No. SW7970820 Renewal Quail Run Business Center High Density Stormwater Project Dare County Dear Mr. Davenport: The Washington Regional Office received a completed Stormwater Renewal Application for the subject project on November 7, 2006. Staff review of the files and an on site inspection has determined that the project will comply with the Stormwater Regulations set forth in Title 15A NCAC 21-1.1000. We are forwarding Permit No. SW7970820 dated January 26, 2007 to Quail Run Business Center, LLC for an infiltration Basin to serve Quail Run Business Center located at 500 Sand Dune Drive in Kitty Hawk, NC. This permit shall be effective from the date of issuance until January 26, 2017 and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. The issuance of this permit does not resolve any previous violations of the stormwater rules for construction without a permit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Roger Thorpe or me at (252) 946-6481. AA er 121 la:z= o ge,`Regional Supervisor Surface Water Protection Section Washington Regional Office cc: ✓Washington Regional Office Central Files North Carolina Division of Water Quality Internet: \\,e'.ncwaterquaht% ore 943 Washington Square Mall Phone (252) 946-6481 Washington, NC 27889 Fax (252) 946-9215 Nne orthCarolina Naturally An Equal OpportunitylAffrmalve Action Employer - 50% Recycled110% Post Consumer Paper State Stormwater Management Systems Permit No. SW7970820 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations . PERMISSION IS HEREBY GRANTED TO Quail Run Business Center, LLC Quail Run Business Center Dare County . FOR THE continued, operation and maintenance of stormwater management systems in compliance with the provisions of 15A NCAC 2H.1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit for an infiltration Basin to serve the Quail Run Business Center located at 500 Sand Dune Drive in Kitty Hawk, NC. This permit shall be effective from the date of issuance until January 26, 2017 and shall be subject to the following specified conditions and limitations: DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 2 of this permit, the Project Data Sheet. 3. A maximum of 1.03 acres of built upon area is allowed. 4. All stormwater collection and .treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with approved plans. 5. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. k DIVISION OF WATER QUALITY PROJECT DATA Project Name: Quail Run Business Center Permit Number: SW7970620 Location: Dare County Applicant: Quail Run Business Center, LLC Mailing Address: 406 W. Lake Drive Kill Devil Hills, NC 27948 Application Date: 11f712006 Receiving Stream: UT Kitty Hawk Bay Classification of Water Body: SC Total Site Area: 1.71 ac Drainage area: 1.71 ac Total Impervious allowed: 1.03 sf Required Storage Volume: 5,615 cf Provided Storage Volume: 13,776 cf Overflow Elevation: 16.0 ft g 6. No homeowner/lot owner/developer shall be allowed to fill in, alter, or pipe any vegetative practices (such as swales) shown on the approved plans as part of the stormwater management system without submitting a revision to the permit and receiving approval from the Division. The following items will require a modification to the permit: a. Any revision to the approved plans, regardless of size b. Project name change c. Transfer of ownership d. Redesign or addition to the approved amount of built -upon area e. Further subdivision of the project area. In addition, the Director may determine that other revisions to the project should require a modification to the permit. 8. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. II. SCHEDULE OF COMPLIANCE The permittee will comply with the following schedule for construction and maintenance of the stormwater management system. a. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surfaces except roads. b. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 2. The facilities must be properly maintained and operated at all times. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency including, but not limited to: a. Semiannual scheduled inspections (every 6 months) b. Sediment removal C. Mowing and revegetation of side slopes d. Immediate repair of eroded areas e. Maintenance of side slopes in accordance with approved plans and specifications f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 6. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Mail the Certification to the Washington Regional Office, 943 Washington Square Mall, Washington, North Carolina, 27889, attention Division of Water Quality. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. III. GENERAL CONDITIONS 1. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143- 215.6(a) to 143-215.6(c). 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. 6. The Permittee, at least six (6) months prior to the expiration of this permit, shall submit in writing a request for an extension along with appropriate application fee. Permit issued this the 26 th day of January 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, P.E. Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number SW7970820 Michael F. Easley, Governor William G. Ross Jr., Secretary rNorth Carolina Department of Environment and Natural Resources 1 .0 Alan W. Klimek, P.E. Director Division of Water Quality October 16, 2006 Quail Run -Office Park Attn: Mr.Mike Davenport 117 Bergen Court Nags Head, NC 27959 Subject:: Stormwater Permit No. SW7970820 Quail Run Office Park Dare County Dear Mr. Davenport: The Division of Water Quality issued a Coastal Stormwater Management Permit, Number SW7970820 for Quail Run Office Park on November 7, 1997. This permit expires on November 7, 2007. Section .1003(h) of 15 A NCAC 2H..1000 (the stormwaterrules) requires that applications for permit renewals shall be submitted 180 days prior to the expiration of a permit and must be accompanied by a processing fee, which is currently set at $420.00. If this is still an active project please complete and submit the enclosed renewal application in a timely manner. If this project has not been constructed and a permit is no longer needed, please submit a request to have the permit rescinded. If you have sold the project, or are no longer the permittee, please provide the name, mailing address and phone number of the person or entity that is now responsible for this permit. Enclosed is a form for change of ownership, which should be completed and submitted if the property has changed hands. Your-permitrequiresthat upon completion of construction and prior to operation of the permitted treatment units a certification of completion be submitted to the Division from an appropriate designer for the system installed. This is to certify that the permitted facility has been installed in accordance with the permit, the approved plans, specifications and supporting documentation. Please include a copy of the certification with your permit renewal request and processing fee. Enclosed is a copy of a sample certification. Also enclosed Is a new Operation and Maintenance agreement that should be completed and submitted along with your renewal application. You should be aware that failure to provide the Designer's Certification and the operation of a stormwater treatment facility without a valid permit, are violations of NC General Statute 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $10,000 per day. If you have any questions, please feel free to contact us at 252-946-6481. i cerel , V I-- Al Hodge, glona upervisor Surface Water Protection Section Washington Regional Office Enclosures cc: Coastal Engineering & Surveying L�Washington Regional Office North Carolina Division of Water Quality Internet: wwwncwaterauality.org One..y, 1 943 Washington Square Mall Phone (252) 946-6481 N.O�^l U1Caroh a Washington, NC 27889 Fax (252) 946-9215 /\ /iitJ mil An Equal Opportunity/Affirmative Action Employer -50%Recycled110% Post Consumer Paper i'fK1v{{'iilLL �/ WATF9 l� NOV - 7 2006 SNACK 11 /tl/n� Michael F. Easley, Governor William G. Ross, Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director DWQ-WARD Division of Water Quality SURFACE WATER PROTECTION SECTION COASTAL STORMWATER PERMIT RENEWAL APPLICATION FORM I. CURRENT PERMIT INFORMATION: 1. Stormwater Management Permit Number: S W 1910 82 O 2. Permit Holder's name: QkaJ QtAn R tcSI'AESs &&Jer.0 L LC 3. Signing official's name: Title: (person legally responsible for pertnk) 4. Mailing address: 041 W. to,kc Dr. City: V111 De' I 4 lls State:f.ZipCode: 71149 Phone: 70 NNt•4)o*AX: X2 - yyt_ 1439-1 (Area Code a d Number) (Area Code a d Num¢er) 5. Project Name: ZtA,&./ /Zi, 11(,C5iVA-ss 6. Location of Project: (street address) J Ooo 1t.., Ur Je. ' 3% 7. Directions to Project (from nearest mayor mtersectlOs intersection) /$•� To PAtr it nosfi" 2. }w�� bti. .d Du,-iZ� Ur�w2 l(iewX2cT leafµ. J Pr1za Z2 P'zza-) II. PERMIT INFORMATION rr 1. Specify the type of stormwater treatment (wet pond, infiltration, etc.): 2. List any changes (from project that was originally approved, attach additional pages if needed) Do you have a copy of the original Operation and Maintenance Agreement? Yes_No_ l. Applicant's Certification: I, (print) N1��1 txaE l�tidQ+PGr� certify that the information in on this permit renewal applica leis to the best o my knowledge, correct and complete. Signature: 41 Date: /1- 6- 06 Submit thi completed form along with an application fee of $420.00 and a copy of the designer's certification to the address listed below. North CaroMa Divlslon of Water Quality 943 Washington Square Mall Phone (252) 946-Ml Customer Service 1-877-623-6748 Washington Regional Office Washington, NC 27889 FAX (252) 946.9215 Internet h2o.enr.state.nc.us One NxthCarolina An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper Qtimall Permit No# S w'?9-70 WET DETENTION BASIN OPERATION AND MAINTENANCE AGREEMENT RECEO VED Maintenance activities shall be performed as follows: NOV — % 2006 1. After every significant runoff producing rainfall event and at least monthly: DWQ-Wp RO a. Inspect the wet detention basin system for sediment accumulation, erosion, trash accumulation, vegetated cover, and general condition. b. Check and clear the orifice of any obstructions such that drawdown of the temporary pool occurs within 2 to 5 days-as'designed. 2. Repair eroded areas immediately, re -seed as necessary to maintain good vegetative cover, mow, vegetative ---cover to maintain a maximum height of six inches, and remove trash as needed. - 3. Inspect and repair the collection system (i.e. catch basins, piping, swales, riprap, etc.) quarterly to maintain proper functioning. 4. Remove accumulated sediment from the wet detention basin system semi-annually or when depth is reduced to 75% of the original design depth (see diagram below). Removed sediment shall be disposed of in an appropriate manner and shall be handled in a manner that will not adversely impact water quality (i.e. stockpiling near a wet detention basin or stream, etc.). The measuring device used to determine the sediment elevation shall be such that it will give an accurate !depth reading arid not readily penetrate into accumulated sediments. When the permanent pool depth reads feet in the main pond, the sediment shall be removed. When the permanent pool depth reads feet in the forebay, the sediment shall be removed. BASIN DIAGRAM (fill in the blanks) Permanent Pool Elevation Sc.liincni Ren ucal LI. �'�� ------------ Sediment Removal Elevation ° Bottom file :uion _ _ ?r°-� — — --� — -- — — --."— _. \ ' Bottom Elevation'--'" / FOREBAY MAIN POND 5. Remove cattails and other indigenous wetland plants when they cover 50% of the basin surface. These plants shall be encouraged to grow along the vegetated shelf and forebay berm. 6. If the basin must be drained for an emergency or to perform maintenance, the flushing of sediment through the emergency drain shall be minimized to the maximum extent practical. 7. All components of the wet detention basin system shall be maintained in good working order. 14.: Remove all trees and heavy woody vegetation from the basins and dike walls. I acknowledge and agree by my signature below that I am responsible for the performance of the eight maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the sys em or responsible party: Print name:il,%a21 Address: _ Lf O G IAA . LG. kA- 'b r . Wa 'bev, I 14 t- (,—vc. Note: The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president. I, u a Notary P blic for the State 1of County of do hereby certify t at personally appeared before me this U day of CA and acknowledge the due execution of the forgoing wet.detention basin maintenance requirements._Witness.my_hand and official seal, My commission expires �A. O-JCt zm Quail Run Commercial Site Mr. Glen D. Davenport Dare County Stormwater Permit No. SW7970820 Designer's Certification I, Carlos F.; Gomez • NOV -1 2006 DWQ-WARO , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, Quail Run Office Park Project) for Quail Run Business Center, LLC (Project Owner) hereby state that to the best of my abilities, due care and diligence was used in the observation of the project construction such that'`the construction was observed to be built within substantial compliance and }ntent of the approved plans and specifications. 1 Signature Registration Number l Y 1407 Date 7-28-1998 EM ++r - J` . �...i .��Sl��.i .i�.r ���u r5'J'.. .)Y .ix 1 :mil~ -C � �� ✓... r.J .; ��.i ! http://www.secretary.state.nc.us/corporations/Corp.aspx?P itemId=4739636 North Carolina Elaine F. Marshall DEPARTMENT OF THE Secretary SECRETARY OF STATE Corporations *Corporations Home •Important Notice •Corporations FAQ •Tobacco Manufacturers *Dissolution Reports •Non -Profit Reports •Verify Certification •Online Annual Reports •KBBE B2B Annual Reports Links *Secretary Of State Home *Register for E-Procurement *Dept. of Revenue •SOSID Number Correction Legislation 01999 Senate Bills 12001 Bill Summaries •Annual Reports 1997 •Corporations 1997 Search *By Corporate Name •For New Corporation 'By Registered Agent Online Orders •Start An Order •New Payment Procedures Contact Us •Corporations Division •Secretary of State's web site Print •Printable Page (New Window) •Printable Page (This Window) •Hide Menu PO Box 29622 Raleigh, NC 27626-0622 (919)807-2000 Date: 1/26/2007 Click here to: View Document Filings I Print apre-populated Annual Report Form I Annual Report Count I File an Annual Report I Corporation Names Name Name Type INC QUAIL RUN Legal BUSINESS CENTER, LLC Limited Liability Company Information SOSID: 0438056 Status: Current -Active Date Formed: 9/19/1997 Citizenship: Domestic State of Inc.: NC Duration: DEC 2030 Registered Agent Agent Name: Registered Office Address: Registered Mailing Address: Principal Office Address: Principal Mailing Address: Davenport, Barbara 406 West Lake Rd Kill Devil Hills NC 27948 406 West Lake Rd Kill Devil Hills NC 27948 406 West Lake Rd Kill Devil Hills NC 27948 No Address For questions or comments about the North Carolina Secretary of State's web site, please send e-mail to Webmaster. I of 1 1/26/2007 1:42 PM V., o �oF W A rFgQ Michael F. Easley, Governor �0 William G. Ross Jr., Secretary C r North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality November 2, 2006 Quail Run Business Center, LLC 406 West Lake Drive Kill Devil Hills, NC 27948 Subject:: Stormwater Permit No. SW7970820 Quail Run Office Park Dare County Dear Owner: The Division of Water Quality issued a Coastal Stormwater Management Permit, Number SW7970820 for Quail Run Office Park on November 7, 1997. This permit expires on November 7, 2007. Section .1003(h) of 15 A NCAC 2H .1000 (the stormwater rules) requires that applications for permit renewals shall be submitted 180 days prior to the expiration of a permit and must be accompanied by a processing fee, which is currently set at $420.00. If this is still an active project please complete and submit the enclosed renewal application in a timely manner. If this project has not been constructed and a permit is no longer needed, please submit a request to have the permit rescinded. If you have sold the project, or are no longer the permittee, please provide the name, mailing address and phone number of the person or entity that is now responsible for this permit. Enclosed is a form for change of ownership, which should be completed and submitted if the property has changed hands. Your permit requires that upon completion of construction and prior to operation of the permitted treatment units a certification of completion be submitted to the Division from an appropriate designer for the system installed. This is to certify that the permitted facility has been installed in accordance with the permit, the approved plans, specifications and supporting documentation. Please include a copy of the certification with your permit renewal request and processing fee. Enclosed is a copy of a sample certification. Also enclosed Is a new Operation and Maintenance agreement that should be completed and submitted along with your renewal application. You should be aware that failure to provide the Designer's Certification and the operation of a stormwater treatment facility without a valid permit, are violations of NC General Statute 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $10,000 per day. If you have any questions, please feel free to contact us at 252-946-6481. ncerely AI Hodge, egional upervisor Surface Water Protection Section Washington Regional Office Enclosures cc: Coastal Engineering & Surveying rfNashington Regional Office North Carolina Division of Water Quality Internet: www.ncwaternualitv.ora One 943 Washington Square Mall Phone (252) 946-6481 No hCarolina Washington, NC 27889 Far (252) 946-9215 Naturallrff An Equal OpportunilylAKrmafive Action Employer— 50% Recycled110% Post Consumer Paper Parcel http:Hwww. daren c. net/publi c/parcelcard. asp? Parce I=029981000+++... Parcel Number: 029981000 1 Submit County of Dare, North Carolina Owner Information: QUAIL RUN BUSINESS CENTER LLC 406 WEST LAKE DRIVE KILL DEVIL HILLS NC 27948 Parcel Information: Parcel:029981000 PIN:987618428142 District: 08 - KITTY HAWK Subdivision: FOYVEST SUBDIVISION LotBlkSect: Lot: 4 & ADJ.PARCEL Blk: Sec: Multiple Lots: - PlatCabSlide: PL: C SL: 114C Units: 1 Deed Date: 12/22/1997 BkPg: 1152/0493 Property Use: Multi Use BUILDING USE and FEATURES BUSE: Comb -Retail / Service Exterior Walls Modular Metal - N/A Interior Walls Drywall - N/A Floors Sheet Vinyl - Carpeting Roof Cover Modular Metal Roof Structure Gable or Hip Heat -Fuel Electric Heat -Type Forced Air / Duct Air Conditioning Central Air MISCELLANEOUS USE Musel: Asphalt Paving Muse2: Muse3: Muse4: Muses: LAND USE LUSE: Kitty Hawk -Comm Highway Primary Luse2: Luse3: Luse4: Luse5: Luse6: LAND AREA: 77000 Square Feet *please see notes below Print Date: 11/2/2006 500 SAND DUNE DR Building Billing Value: $692,900 Actual Year Built: 1998 Baths: 7 Bedrooms: 0 FINISHED SQ FT: *please see notes below* drawingl =6250 Mise Billing Value: $25,200 Land Billing Value: $917,400 Total Billing Value: $1,635,500 *The Finished Square Footage of the building(s) and the Land Area information is based on data in the Tax Appraisal program as of May 2006, and will be updated at least twice a year. 1 of 1 1/2/2006 2:44 PM Parcel http://www.darenc.net/public/parceicard.asp?Parcel=02998 1000+++... *Finished Square Footage indicates the area of a building that is heated or unheated and has interior finish. The finished square footage is shown for up to 3 drawings per parcel from the Tax Appraisal program. Usually each drawing denotes one building. Larger, or more involved buildings sometimes require two or more drawings in the Tax Appraisal program, and in these cases the finished square footage of these drawings will need to be added together for the total finished area. The Appraisal office can confirm whether a building involves more than one drawing. 2 of 2 1 1/2/2006 2:44 PM tt`tATF9oG O�Qrr Michael F. Easley, Governor William G. Ross Jr., Secretary rNorth Carolina Department of Environment and Natural Resources p Y Alan W. Klimek, P.E. Director _ Division or Water Quality October 25, 2006 Davco Electric Incorporated Attn: Mr. Glen D. Davenport 201 W Main Street Creswell, NC 27928 Subject:: Stormwater Permit No. SW7970820 Quail Run Office Park Dare County Dear Mr. Davenport: The Division of Water Quality issued a Coastal Stormwater Management Permit, Number SW7970820 for Quail Run Office Park on November 7, 1997. This permit expires on November 7, 2007. Section .1003(h) of 15 A NCAC 2H .1000 (the stormwaterrules) requires that applications for permit renewals shall be submitted 180 days prior to the expiration of a permit and must be accompanied by a processing fee, which is currently set at $420.00. If this is still an active project please complete and submit the enclosed renewal application in a timely manner. If this project has not been constructed and a permit is no longer needed, please submit a request to have the permit rescinded. If you have sold the project, or are no longer the permittee, please provide the name, mailing address and phone number of the person or entity that is now responsible for this permit. Enclosed is a form for change of ownership, which should be completed and submitted if the property has changed hands. Your permit requires that upon completion of construction and prior to operation of the permitted treatment units a certification of completion be submitted to the Division from an appropriate designer for the system installed. This is to certify that the permitted facility has been installed in accordance with the permit, the approved plans, specifications and supporting documentation. Please include a copy of the certification with your permit renewal request and processing fee. Enclosed is a copy of a sample certification. Also enclosed is a new Operation and Maintenance agreement that should be completed and submitted along with your renewal application. You should be aware that failure to provide the Designer's Certification and the operation of a stormwater treatment facility without a valid permit, are violations of NC General Statute 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $10,000 per day. If you have any questions, please feel free to contact us at 252-946-6481. Ancere y, Al Hodge, upervisor Surface Water Protection Section Washington Regional Office Enclosures cc: Coastal Engineering & Surveying Washington Regional Office North Carolina Division of Water Quality Internet: www.ncwaterguality.org One 1 943 Washington Square Mall Phone (252) 946-6481 - NOrffiCarOf ttta Washington, NC 27889 Fax (252) 946-9215 Naturally An Equal OpporlunitylAffirmative Action Employer- 50%Recycled110% Post Consumer Paper WaRO Michael F. Easley, Governor William G. Ross Jr., secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality October 13, 2006 Quail Run Office Park Attn: Mr. Glen D. Davenport 22242 Hwy 64 Creswell, NC 27928 Subject:: Stormwater Permit No. SW7970820 Quail Run Office Park Dare County Dear Mr. Davenport: The Division of Water Quality issued a Coastal Stormwater Management Permit, Number SW7970820 for Quail Run Office Park on November 7, 1997. This permit expires on November 7, 2007. Section .1003(h) of 15 A NCAC 2H .1000 (the stormwater rules) requires that applications for permit renewals shall be submitted 180 days prior to the expiration of a permit and must be accompanied by a processing fee, which is currently set at $420.00. If this is still an active project please complete and submit the enclosed renewal application in a timely manner. If this project has not been constructed and a permit is no longer needed, please submit a request to have the permit rescinded. If you have sold the project, or are no longer the permittee, please provide the name, mailing address and phone number of the person or entity that is now responsible for this permit. Enclosed is a form for change of ownership, which should be completed and submitted if the property has changed hands. Your permit requires that upon completion of construction and prior to operation of the permitted treatment units a certification of completion be submitted to the Division from an appropriate designer for the system installed. This is to certify that the permitted facility has been installed in accordance with the permit, the approved plans, specifications and supporting documentation. Please include a copy of the certification with your permit renewal request and processing fee. Enclosed is a copy of a sample certification. Also enclosed is a new Operation and Maintenance agreement that should be completed and submitted along with your renewal application. You should be aware that failure to provide the Designer's Certification and the operation of a stormwater treatment facility without a valid permit, are violations of NC General Statute 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $10,000 per day. If you have any questions, please feel free to contact us at 252-946-6481. /S�ncerely, ' L ,-1��Tarl S—� At Hodge,�egiohupervisor Surface Water Protection Section Washington Regional Office Enclosures cc: astal Engineering & Surveying ashington Regional Office North Carolina Division of Water Quality Internet: w %y.ncwaterqualitv.ore One 943 Washing on Square Mall Phone (252) 946-6481 NorthCarohna Washington, NC 27899 Fax (252) 946-9215 Naturally �%i/ rail// An Equal Opportunity/Affirmative Action Employer— 50%Recycled110% Post Consumer Paper �/y `K`K!{!� Y October 25, 2006 Davco Electric Incorporated Attn: Mr. Glen D. Davenport 201 W Main Street Creswell, NC 27928 Subject:: Stormwater Permit No. SV 7970820 Quail Run Office Park Dare County Dear Mr. Davenport: ►,� o Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality The Division of Water Quality issued a Coastal Stormwater Management Permit, Number SW7970820 for Quail Run Office Park on November 7, 1997. This permit expires on November 7, 2007. Section .1003(h) of 15 A NCAC 2H .1000 (the stormwater rules) requires that applications for permit renewals shall be submitted 180 days prior to the expiration of a permit and must be accompanied by a processing fee, which is currently set at $420.00. If this is still an active project please complete and submit the enclosed renewal application in a timely manner. If this project has not been constructed and a permit is no longer needed, please submit a request to have the permit rescinded. If you have sold the project, or are no longer the permittee, please provide the name, mailing address and phone number of the person or entity that is now responsible for this permit. Enclosed is a form for change of ownership, which should be completed and submitted if the property has changed hands. Your permit requires that upon completion of construction and prior to operation of the permitted treatment units a certification of completion be submitted to the Division from an appropriate designer for the system installed. This is to certify that the permitted facility has been installed in accordance with the permit, the approved plans, specifications and supporting documentation. Please include a copy of the certification with your permit renewal request and processing fee. Enclosed is a copy of a sample certification. Also enclosed is a new Operation and Maintenance agreement that should be completed and submitted along with your renewal application. You should be aware that failure to provide the Designer's Certification and the operation of a stormwater treatment facility without a valid permit, are violations of NC General Statute 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $10,006 per day. If you have any questions, please feel free to contact us at 252-946-6481. Ancere y, 7. Al Hodge, upervisor Surface Water Protection Section Washington Regional Office Enclosures cc: stal Engineering & Surveying CXshington Regional Office North Carolina Division of Water Quality Internet: www.ncwaterquality.org One 943 Washington Square Mall Phone (252) 946-6481 NorthCarolina Washington, NC 27889 Fax (252) 946-9215 Naf//�+Y An Equal Opportunity/Affirmative Action Employer-50%Recycled110% Post Consumer Paper DKL [I 00 Coas,oal ENGINEERING & SURVEYING, INC. a August 13, 1997 WASHIN TONE OFFICE Mr. William J. Moore UG 2 0 1997 NCDEHNR Division of Water Quality D. & M. 943 Washington Square Mall F t Washington, NC 27889 u RE: Quail Run Park; Kitty Hawk, NC Dear Mr. Moore: Attached for your review and approval is a Stormwater Management Permit Application and a check for $385.00. Copies of the attached plans have been submitted to the Town of Kitty Hawk for their review and approval of the erosion control measures to be employed on the project. As indicated on the plan, Quail Run Park will be constructed in two phases. The infiltration basin has been designed to accommodate both phases. The infiltration basin and storm drainage system will also be constructed during Phase 1. During July of this year, this firm conducted hand auger borings in the area of the proposed infiltration basin. Based on these borings and the existing topography we estimate the seasonal high water table to be below 8' msl. We have therefore established a bottom of basin elevation of 10' msl in order to maintain the required two foot separation between the groundwater and bottom of basin. Your time and assistance is appreciated . If you have any questions or require additional information, please do not hesitate to give us a call at 261-4151. Sincerely, 55 James M. Conners, RLA JMCrwm File: msworks4nisc.97248.1 3915 Welch Street. P.O. Box 1129 -Kitty Hawk, NC 27949 . (919) 261-4151 NGTON O WASHFFICE IN 2 0 1997 U6LM. om3csIe,►r. Im.opa::ou 1. Project Naar: a ,. $. Project Location: (County, State Read, Address) 'Te4w#4 OE 4P.-e Or.i tit DHNE CXti "07 /^, �JaVertPm�.-- ihonet.�1/eH5 3. Owner's Name:-,c��,„lf6ara 4. Mailing Addrees: Q �ztiz �v 4 //7 �q state '1,�GLip a't928_ City it ,. _..__.S• pig* Submitted.. -60 Application Datm: 12. 6. Nearest Receiving Stream: Class: 7. ProjectDeecription: 1 5'e0 rck Wes;�„� II. r9ULIT I]IIORMi1TIGIN VeV,�/ '68✓�, 1. Permit NO• (will be completed by ONQ)s 5� 7 9 7 06 Z-0 �w IM duwok 2. Permit 'types New Renewal Renewal . b/ P Moelficatior. (arl.sLiag pyr_miC 00.) `" ISS�+� LOU Dandiur High Density 1/ /-7 3. Project Type:. General larait other -. 4. other State/Federal Permits/Approvals Ragnired: (Check appropriate blanks) Ssdimont/Erosion Control CAM Major 404 Permit III. pRo.7ECT BUILT UPON ARPA classification Allowable Impervious Proposed Impervious Total Project Area % Impervious Area Drainage Drainage b A CW LOCO y4h s ><a.,w., of Imoety sous can Buildings Roads Parking other Totals f v • �- rg, SOpMWAMM TMUTMW (Describe how runoff will be treated): yy ZeV Yi-5b Yu mil! i 1 tu—T�.�'7':U�I S!/�) -r*-W ! n 9(h ED M V. r DSW RESMUCTIOmS MW PROTECTIVE COVZWUM .. Deed restrictions and protective covenants are required for all low density projects and all subdivisions prior to the sale of any lot. please one Attachment A for specific requirements. Ey your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the items required by the permit, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the covenant cannot be changed or deleted without concurrence from the State, and that they will be recorded prier to the sale of any lot. 1 r GI�� �CtU�✓�YJpr� certify that the (Please pnnL rAve clemrly) information included on this permit application form is correct, that the project will be constructed in conformance with the approved plans, that the deed restrictions will be recorded with all required permit conditions, and that to the beat of my knowledge, the proposed project complies with the requirements of ISA NCAC 29.1000. I authorize the below named person or firm to submit stormwater plans on A. Person or rl.rm Mmee gailing Address! city — _ - State Phone: Zip please submit application, foe and plans to appropriate Regional Office - (see attached map) INFILTRATION POND MAINTENANCE Project Name: QwWJJttn Responsible Party Name: Glen D & HAdamlDAYMP= Address: 22242 11ighway 64 Crgswell 1(C 27928 Phone No: (919) 7974645 After every runoff producing rainfall event, or at least monthly, whichever comes first: 1. Inspect the infilration pond(s) for erosion, trash accumulation, grass eoverage,and general condition of the facility. 2. Repair eroded areas immediately, re -seed as necessary, keep side slopes and bottom mowed, and remove trash. 3. Check any inlet piping, swales and catch basins. Repair broken piping, reseed swales, and remove trash. 4. Inspect the bypassloverflow structure for blockage and deterioration. Remove blockage and repair structure to originally approved design specifications. 5. Check the Jepth of the pond(s) every six months. IF siltation has occured to the point that only 75% of the original design depth is provided, remove the excess silt to the original depth. Do not over -excavate, as this may cause the required water table separation to be reduced, and may affect the ability of the system to perform as designed. SEE ATTACHMENT A tl I, 61 D , Q Ve of 0 l"t, agree to be responsible for performing the maintenance items as listed above for this project. 1 agree to notify NCDWQ of any problems with the system, or changes of the name of the project, name of the responsible party, or address Signaturex�=6C11 Gl 1� B LL e1�. 6� C/ Date O �' q % 1. The connection from the outparcel of future area into the stormwater system must be into the forebay such that short-circuiting of the system does not occur. 2. All built -upon area from the outparcel of future development must be directed into the permitted stormwater control. 3. Built -upon area in excess of that permitted amount will require a permit modification prior to construction. For curb outlets systems, the following statements, in addition to Nos. 1 and 2 above, must be recorded: 4. No one may pipe, fill in, or alter any designated 100' long grassed Swale used to meet the requirements ofNCAC 2H.1008(g). State of North Carolina Department of Environment and Natural Resources Washington Regional Office James B. Hunt, Jr., Governor Wayne McDevitt, Secretary DIVISION OF WATER QUALITY November 7, 1997 Mr. Glen D. Davenport 22242 Hwy 64 Creswell, NC 27928 Dear Mr. Davenport: "R/(14 ..'``5mTEa lrt/Tif '� au.M Vo''• Subject: Permit No. SW7970820 Quail Run Commercial Site Phases 1 & 2• High Density Stormwater Project Dare County The Washington Regional Office received the completed Stormwater Application for the subject project on October 1, 1997. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW7970820 dated November 7, 1997 to Mr. Glen Davenport. This permit shall be effective from the date of issuance until November 7, 2007 and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. 943 Washington Square Mall, Washington, North Carolina 27889 Telephone 919-946-6481 FAX 919-975-3716 An Equal Opportunity Affirmative Action Employer Mr. Glen Davenport November 7, 1997 Page Two If you have any questions, or need additional information concerning this matter, please contact Bill Moore at (919) 946- 6481, extension 264. Sincerely, �� . K. oger Thorpe Water Quality Supervisor Washington Regional Office cc: Coastal Engineering Dare County Inspections shington Regional Office Central Files State Stormwater Management Systems Permit No. SW7970820 STATE OF NORTH CAROLINA OF ENVIRONMENT AND NATURAL DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Mr. Glen D. Davenport Dare County FOR THE construction, operation and maintenance of stormwater management systems in compliance with the provisions of 15A NCAC 2H.1000 (hereafter referred to as the ^stormwater rules") and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit for an infiltration basin to serve the Quail Run Commercial Site, Phases 1 & 2, located at Kitty Hawk, NC. This permit shall be effective from the date of issuance until November 7, 2007 and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 4 of this permit, the Project Data Sheet. 3. Approved plans and specifications for .this 'project are incorporated by reference and are enforceable parts of the permit. 3 Ll DIVISION OF WATER QUALITY PROJECT DATA Project Name: Permit Number: Location: Applicant: Mailing Address: Application Date: Water Body Receiving Stormwater Runoff: Classification of Water Body: Pond/Basin Depth: Total Site Area: Total Imper. Surfaces Allowed: Required Surface Area: Provided Surface Area: Required Storage Volume: Provided Storage Volume: Controlling Orifice: Quail Run Commercial Site SW7970820 Dare County Mr. Glen D. Davenport 22242 Hwy 64 Creswell, NC 27928 8/20/97; original 10/01/97; complete UT - Kitty Hawk Bay Sc 6.0 feet 1.71 acres 1.03 acres N/A N/A 5615 cubic feet 13,776 cubic feet overflow spillway set at elev 16 feet 4 4. No homeowner/lot owner/developer shall be allowed to fill in, alter, or pipe any vegetative practices (such as swales) shown on the approved plans as part of the stormwater management system without submitting a revision .to the permit and receiving approval from the Division. 5. The following items will require a modification to the permit: a. Any revision to the approved plans, regardless of size b. Project name change C. Transfer of ownership d. Redesign or addition to the approved amount of built -upon area e. Further subdivision of the project area. In addition, the Director may determine that other revisions to the project should require a modification to the permit. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. II. SCHEDULE OF COMPLIANCE 1. The permittee will comply with the following schedule for construction and maintenance of the stormwater management system. a. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surfaces except roads. b. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 2. The facilities must be properly maintained and operated at all times. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency including, but not limited to: 0 a. Semiannual scheduled inspections (every 6 months) b. Sediment removal C. Mowing and revegetation of side slopes d. Immediate repair of eroded areas e. Maintenance of side slopes in accordance with approved plans and specifications f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 6. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Mail the Certification to the Washington Regional Office, 943 Washington Square Mall, Washington, North Carolina, 27889, attention Division of Water Quality. 7. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. III. GENERAL CONDITIONS 1. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by. the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6(a) to 143-215.6(c). 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 6 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. Permit issued this the 7 th day of November, 1997. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION y.-A. Pre9ton Howard, Jr., P.E., Director Division of Water Quality By Authority of the Environmental Management commission Permit Number SW7970820 7 W 'r 1 Quail Run Commercial Site Mr. Glen D. Davenport Dare County Stormwater Permit No. SW7970820 Designer's Certification I, , as a duly registered Professional Engineer in the,State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, for (Project) (Project Owner) hereby state that to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Signature Registration Number Date 0 Quail Run Park Kitty Hawk, North Carolina Stormwater Management Calculations August 14, 1997 Prepared By: Coastal Engineering & Surveying, Inc. P.O. Box 1129 Kitty Hawk, NC 27949 RCE WASH1NcEroN pFFICE AUG 2 0 1997 M. �„pseoee000,o - t••••���4 SSIQ� SE 0. • F ,•ly Signature /Iq -7 7r .. JOB ___P 41-49 QUAIL Rurj PART. COASTAL ENGINEERING SHEET NO. & SURVEYING, INC. of .1 P.O. Box 1129 CALCULATED By W DATE �� ULrUST �%IT KITTY HAWK, NC 27949 CHECKEDBY DATE Phone (919) 261-4151 Fax (919) 261-1333 1 JOB 71�-24L� COASTAL ENGINEERING SHEET NO. ;7— OF & SURVEYING, INC. P.O. Box 1129 CALCULATED BY :?Tt� DATE 04- KITTY HAWK, NC 27949 Phone (919) 261-4151 Fax (919) 261-1333 CHECKED BY DATE SCALE .. ..... ...... . .... . . ......... . ...... ..... . .... ..... ... ...... ... ........ .. 1`7 0 /1734P AiCr- .. ........ . . ... .......... .. .......... . . ........... . . .. ... ... ... ... .. . ............. . . ..... .............. . . .. - ............ ........ .. .. .. . ..... . . ..... Y is),(o, ......... . ... wl;5 Ap. ✓fDP�� 1)712 (5mo.-T..6- iqF, .. . ................... ............ . .......... (5E...... . ......... - n j .. .. . ............... . 0 1�6 . . . ... . .. ... .. /Z .. . . .... ..... .. .... . .. ..... . . ...... .... .... ... Mid 17X� 14- r 7 . ..... All- ............ . . . ....... .... . ...... ..... - .... . ...... . - - ... ... ...... .. ... .. . ....... ............ ......... ....... . . ......... . ...... . ..... ... .. .. ... ........ .... - ...... ...... . ..... . ....... ... . ...... ....... ....... ...... . . . . ........... . . .......... ... . .. . .. ... ... . ... ........ . ........ - ........... . . .... . .... L ............ . . ..... . ............. 0.1.1-1- .... ....... ............ ..... . .... . ........... .. .. ......... . • 'M- r . ........ .. . ..... ...... .......... .. . .......... . . ... .. .... .. .. . . . ...... .... .......... . ........... ....... .... ........ - -------- - -- v -- ----- -- r ...... . .... . . .. .... . . . ....... . . .... ..... . ...... MIN. �p ..... ... . .......... . . .. ... .. .. . .. ........ .... . ............ ... .. ...... .. ...... .... . L-.- , ... .. .. ... .. -an .... . ...... ... .. ... .. . . . ... /J,. . ... ... .. .. I., L .. ..... ..... ..... .. 096 0 . .......... ........... . . .... .. ... �k.S=Do9� ,, o a�N �. DI ,�.�„ A$ ... ... ... .. ......... . M;, .. ... .. ... ........... ... ....... . ....... . . . ...... . ........ ... ............ . . . .... . .......... ........ . ....... .. . .... .. ... ..... .. ......... . .. . ............. . . . . .......... ........... ............ .. .... ... . ....... ... ... ... . .. . . .. .... . .. . . ....... .. .... .. .... .... JOB fq�og COASTAL ENGINEERING SHEET NO. 3 OF & SURVEYING, INC. P.O. Box 1129 CALCULATED BYyy �J DATE ✓� ��LSI KITTY HAWK, NC 27949 CHECKED BY DATE Phone (919) 261-4151 Fax (919) 261.1333 snei F 9H �S�k 6Ne6� ASI (PYde1) JOB COASTAL ENGINEERING SHEET NO. OF & SURVEYING, INC. P.O. Box 1129 CALCULATED BY—r-lt7J DATE O'- KITTY HAWK, NC 27949 Phone (919) 261-4151 Fax (919) 261-1333 CHECKED BY DATE SCALE ...... .... . ........ ..... .. ... ........ .. . . .. .. ... ... ..... ................... .. . ........... .. ......... . ... . . .. .. . .... ............ ............. ........... ....... .. .. ........... ...... . ... .. ..... ........ - .... ........ ............ .... J i9l 4��5 ( I/P I ........ ... ............ . . . . ... .. .. - .. . ........................ .. .. ... ... . . ..... . ... ........... . ..... ....... ............ 12, 08 ............ . .. .. .. .. . ...... ............ . .. . ........ . .. . . ... . ........ ..... . .... . . . . .......... . .. ....... . 7 ..... . ........... . ..... ......... .... .......... .. .... .. ... .. . .......... • ng: -4� PIN �t' ... .. .... .. .. ........ . ... .... . ......... .. .. ... . ..... ..... a, 4 ..... .... . . . ........... .......... ....... yz.. .... q ........ .. ... ........ - . . ......... ... . ..... .... . .. .L..... . . .. .. .. . .. ... ...... ... . . ....... .. ...... . ...... ....... . ......... . . .. .. .......... . ............ .. .. ... ... ........ .. .. ... ..... . . ..... ........ ... . . ............... . ...... .... ...... .. ......... . ...... ... . ......... . ..... . ........... ..... ...... ...... . ...... ... .... ............. to 1'2. . . .............. . . ..... . ....... . ... .. . ............ ........... ......... ... . ....... ........ ............ . ............ - 41 . . .. . .. . ....... .. . . . ..... . ..... ............ .. ... ........ ............. ..... - .. .. .. .... ....... .... ....... ... ... .. ...... .. . ......... ....... .... . ........... .......... I . . . ..... . .... 0 ....... .... . ... .. . ...... . ......... . ...... - ......... - ....... ... . ..... .. ..... . .... .. .. ...... . ............ . .. . ... ......... .. .... .... .. .. ........ . ... ............. ..... ....... ........ ............. . . .. . .. ..... . .... ... .. . ............ . . ... ...... .. ... ....... .... ......... ..... .. . ........ . ......... .. Oct .. . .......... ............ . ........ .. ................. .... .. ..... .... ........ ......... . ....... .. ... .. ..... ... . .. .. ... . .......... . . ... ... . . ......... ........ ... .. . ... . .. .. . ....... . . . ......... COASTAL ENGINEERING & SURVEYING, INC. P.O. Box 1129 KITTY HAWK, NC 27949 Phone (919) 261-4151 Fax (919) 261-1333 joB F9WZ91?f QURuL _iL))J PAI;/ SHEET NO. 5 OF �� CALCULATED BY— HIN] Dq� �3 Alt,LL,o,s /914 CHECKED BY DATE Sra F COASTAL ENGINEERING & SURVEYING, INC. P.O. Box 1129 KITTY HAWK, NC 27949 Phone (919) 261-4151 Fax (919) 261-1333 SHEET NO, "%' OF CALCULATED BY"yt, DATE CHECKED BY DATE COASTAL ENGINEERING & SURVEYING, INC. P.O. Box 1129 KITTY HAWK, NC 27949 Phone (919) 261-4151 Fax (919) 261-1333 JOB 97248 SHEETNO. Afew �'InK.,.'AOF �} CALCULATED BY U /W DATE -7-9 ` CHECKED BY i'yJ new ';'( SCALE _._.._ _.... ..._..._. n sr� rr ..... of Z... o ! �MJa .. �Gb/�¢ ...._.... . vp HID 4O.olz . no ,Oooaz3. _ ofzz-324 OI ZZ% rog n=o.o�z :5„N 000095q_ oo957� oa9c9 �.P� a .� / .......... -; ..: ..... wopf :. :.......... _ r o, oit . SmW 0 O(o5.% d= 24 Z Appendices moms uuu■■�u■■■momm ■��I�uuuu■■emu■■■��►.��� 5 10 20 40 60 2 3 4 6 8 12 18 24 Minutes Hours Duration I Figure 8.03b Rainfall intensity duration curves—Wilrnington. l 5 10 20 40 60 2 3 4 6 8 12 18 24 Minutes - Hours Duration t\ Figure 8.03c Rainfall intensity duration curves —Hatteras. 8.03.5 1INC. . X.�BROWNE ASSOCIATES, W .1 M M KIQRT M f!R [0 1lWA- - . Figure 3.3 Average Velocities for Est �' me ted Travel Ti for Overland Flow Source: Urban Hydrology for Small Watersheds, 1975. 3_7 r - ' MFMTRATION BASIN ATTACHMENT 1, BUILTUPON AREA CALCULATION (See NCAC 2H.1008 (c) and (d) for applicable design crierta. In cases where more than one basin is proposed, please list each basiness information in separate columns. Basin k 1 Classification inflitnojpn Existing Built -Upon Area OSF Proposed Built•Upon Area 44 91 B sf Total Project Area 74,¢gQgsf Total Drainage Area 44.9I8sf Percent Built -Upon 60% 11. BREAKDOWN OF PROPOSED BUILT -UPON AREA Building MQ0sf _lots ra _soot Streets Parking 24.566sf Sidewalks 2 852sf included in Future Development above flizures Other N/A IIL BASIN DESIGN Basin Depth 6' Required Volume 5 615 cf Provided Volume 13,776 cf Bottom Surface Area 922 sf Storage Surface Area 3670 sf Bottom Elevations 10 0, msl Storage Elevations 16.01 Type of Soil sand_ Expected Infiltration Rate SHw T Elevation below 8, msl