HomeMy WebLinkAboutSW7110312_CURRENT PERMIT_20110411STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE CURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD 7XAwi NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director . Secretary Mr. George Pitsilides, Manager Pitco 1, LLC 1956 Laskin Road Virginia Beach, VA 23454 Subject: Stormwater Permit No. SW7110312 Pitco 1, LLC — Parking Lot High Density Project Dare County Dear Mr. "Pitsilides: The Washington Regional Office received a complete Stormwater Management Permit Application for Pitco 1, LLC — Parking Lot project on March 31, 2011. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Session Law 2008-211 and Title 15A NCAC 21-1.1000. We are forwarding Permit No. SW7110312 dated April 11, 2011, for the construction of the subject project. This permit shall be effective from the date of issuance until April 11, 2021, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Samir Dumpor, or me at (252) 946-6481. Ancer ly, -L Al Ho Regional Supervisor Surface Water Protection Section AH/sd: K:\SD\Permits - Infiltration\SW7110312 cc: Michael Morway, PE, Albemarle & Associates, Ltd. Pare County Building Inspections ,/Washington Regional Office North Carolina Division of Water Quality Internet: www.newaturquality.ol 943 Washington Square Mall Phone: 252-946-6481 One t Washington, NC 27889 FAX 252-946-9215 An Equal Opportunity/Affirmative Action Employer- 50%Recycedll0%Post Consumer Naturalmer Paper Nortulralj111 lrt State Stormwater Management Systems Permit No. SW7110312 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Pitco 1, LLC Pitco 1, LLC — Parking Lot Dare County FOR THE construction, operation and maintenance of an infiltration basins, in compliance with the provisions of Session Law 2008-211 and 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until April 11, 2021, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described in Section 1.8 on page 3 of this permit. The stormwater control has been designed to handle the runoff from total of 27,981 square feet of impervious area. 3. The tract will be limited to the amount of built -upon area indicated in Section 1.7 on page 3 of this permit, and as shown on the approved plans. 4. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. 5. The runoff from all built -upon area within the permitted drainage area of this project must be directed into the permitted stormwater control system. 6. The built -upon areas associated with this project shall be located at least 50 feet landward of all surface waters. 7. The following design criteria have been permitted for the infiltration basin and must be provided and maintained at design condition: Page 2 of 7 State Stormwater Management Systems Permit No. SW7110312 INFILTRATION BASIN a. Drainage Area, ft`: 45,000 b. Total Impervious Surfaces, ft2: 27,981 C. Design Storm, inches: 1.5" d. Basin Depth, feet: 1.30 e. Bottom Elevation, FMSI : 6.10 f. Bottom Surface Area, ft : 5,607 g. Bypass Weir Elevation, FMSy 7.40 h. Permitted Storage Volume, ft : 6,966 i. Type of Soil: Corolla Duckston complex j. Expected Infiltration Rate, in/hr: 20.0 k. Seasonal High Water Table, FMSL: 4.10 I. Time to Draw Down, days: 0.04 M. Receiving Stream/River Basin: Pasquotank River Basin/Kitty Hawk Bay n. Stream Index Number: 30-19 o. Classification of Water Body: "SC" II. SCHEDULE OF COMPLIANCE The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of bypass structure, infiltration media, flow spreader, catch basins, piping and vegetated filter. g. A clear access path to the bypass structure must be available at all times. 4. Records of maintenance activities must be kept for each permitted BMP. The reports will indicate the date, activity, name of person performing the work and what actions were taken. 5. The facilities shall be constructed as shown on the approved plans. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 6. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the Page 3 of 7 State Stormwater Management Systems Permit No. SW7110312 approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. 8. Access to the stormwater facilities shall be maintained via appropriate easements at all times. 9. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area or to the drainage area. e. Further subdivision, acquisition, lease or sale of all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 10. The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction. 11. A copy of the approved plans and specifications shall be maintained on file by the Permittee at all times. 12. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. III. GENERAL CONDITIONS This permit is not transferable to any person or entity except after notice to and approval by the Director. In the event of change of ownership, or a name change, the permittee must submit a completed Name/Ownership Change form to the Division of Water Quality, signed by both parties, and accompanied by the appropriate documentation as listed on page 2 of the form. The approval of this request will be considered on its merits and may or may not be approved. 2. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. 3. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 4. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. Page 4 of 7 State Stormwater Management Systems Permit No. SW7110312 6. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 7. The permit issued shall continue in force and effect until revoked or terminated. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. 8. Unless specified elsewhere, permanent seeding requirements for the stormwater controls must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 9. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 10. The issuance of this permit does not prohibit the Director from reopening and modifying the permit, revoking and reissuing the permit, or terminating the permit as allowed by the laws, rules and regulations contained in Session Law 2008-211, Title 15A NCAC 21-1.1000, and NCGS 143-215.1 et. al. 11. The permittee shall notify the Division in writing of any name, ownership or mailing address changes at least 30 days prior to making such changes. 12. This permit shall be effective from the date of issuance until April 11, 2021. Application for permit renewal shall be submitted 180 days prior to the expiration date of this permit and must be accompanied by the processing fee. Permit issued this the 11th day of April, 2011. NO TH AROLINA ENVIRONMENTAL MANAGEMENT COMMISSION LL. for oleen H. Ilins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit No. SW7110312 Page 5 of 7 State Stormwater Management Systems Permit No. SW7110312 Pitco 1, LLC — Parking Lot Stormwater Permit No. SW7110312 Dare County Designer's Certification I, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/ weekly/ full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specification: Signature Registration Number Date SEAL Page 6 of 7 State Stormwater Management Systems Permit No. SW7110312 Certification Requirements: 1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4. All roof drains are located such that the runoff is directed into the system. 5. The bypass structure weir elevation is per the approved plan. 6. The bypass structure is located per the approved plans. 7. A Trash Rack is provided on the bypass structure. 8. All slopes are grassed with permanent vegetation. 9. Vegetated slopes are no steeper than 3:1. 10. The inlets are located per the approved plans and do not cause short- circuiting of the system. 11. The permitted amounts of surface area and/or volume have been provided. 12. All required design depths are provided. 13. All required parts of the system are provided. 14. The required system dimensions are provided per the approved plans. cc: NCDENR-DWQ Regional Office Dare County Building Inspections Page 7 of 7 II 1nW1RMMfto'D I Fee Paid cae.3t (rR n I Permit Number II II 1 $ L4-ono I is-^) -1 ( I n � tz II :able RIM: J I EWHastal SW -1995 ❑ Coastal SW - 2008 ❑ Ph 11- Post Construction all that apply)_ O Non -Coastal SW- HQW/ORW Waters ❑ Universal Stormwater Management Plan State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original I. GENERAL INFORMATION 1. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): 2. Location of Project (street address): 407 South Memorial Avenue, Kill Devil Hills, NC. 27948 City:Kill Devil Hills County:Dare Zip:27948 3. Directions to project (from nearest major intersection): From the intersection of US-158 and SR-1217 (Colington Road), proceed east along SR-12171 blocks to Memorial Drive and turn south onto Memorial Drive. Proceed 4 blocks (approx. 8001). The site is on the left including 2 vacant lots and 2 existing homes (on the south) 4. Latitude:36° W 42" N Longitude:751 39' 26" W of the main entrance to the project. II. PERMIT INFORMATION: 1.a.Specify whether project is (check one): ®New ❑Modification b.lf this application is being submitted as the result of a modification to an existing permit, list the existing permit number , its issue date (if known) , and the status of construction: ❑Not Started [-]Partially Completed* ❑ Completed* *provide a designer's certification 2. Specify the type of project (check one): ❑Low Density ®High Density ❑Drains to an Offsite Stormwater System ❑Other 3. If this application is being submitted as the result of a previously returned application or a letter from DWQ requesting a state stormwater management permit application, list the stormwater project number, if assigned, and the previous name of the project, if different than currently proposed, 4. a. Additional Project Requirements (check applicable blanks; information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748)> ❑CAMA Major ❑NPDES Industrial Stormwater ®Sedimentation/Erosion Control: 1.06 ac of Disturbed Area ❑404/401 Permit: Proposed Impacts b.If any of these permits have already been acquired please provide the Project Name, Project/Permit Number, issue date and the type of each permit: Ill. CONTACT INFORMATION 1. a. Print Applicant / Signing Official's name and title (specifically the developer, property owner, lessee, designated government official, individual, etc. who owns the 12rojectl: Applicant/Organization:Pitco 1, LLC Signing Official & Title:George Pitsilides, Manager b.Contact information for person listed in item la above: Street Address:1956 Laskin Road City:Virginia Beach State:Va Zip:23454 Mailing Address (if City: Phone: Email: State: Zip: Fax: c. Please check the appropriate box. The applicant listed above is: ❑ The property owner (Skip to Contact Information, item 3a) ❑ Lessee* (Attach a copy of the lease agreement and complete Contact Information, item 2a and 2b below) ® Purchaser* (Attach a copy of the pending sales agreement and complete Contact Information, item 2a and 2b below) ❑ Developer* (Complete Contact Information, item 2a and 2b below.) 2. a. Print Property Owner's name and title below, if you are the lessee, purchaser or developer. (This is the person who owns the property that the project is located on): Property Owner/Organization:On Trading Corp Signing Official & Title:Nicholas Nuzzi, Vice President b.Contact information for person listed in item 2a above: Street Address:100 Carlton Avenue City:Kill Devil Hills State:NC Zip:27948 Mailing Address (if applicable):PO Box 389 City:Kill Devil Hills Phone: (252 ) 480-3037 State:NC Zip:27948 Fax: ( I 3. a. (Optional) Print the name and title of another contact such as the projects construction supervisor or other person who can answer questions about the project: Other Contact Person/Organization: Signing Official & b.Contact information for person listed in item 3a above: Mailing State: Phone: ( 1 Fax: 4. Local jurisdiction for building permits: Kill Devil Hills Point of Contact:Shanda Davenport IV. PROJECT INFORMATION Phone #: (252 ) 449-5318 1. In the space provided below, briefly summarize how the stormwater runoff will be treated. Runoff from the parking lot will sheet flow into infiltration basins on either side. The basin are hydraulically linked with pipes. A drop inlet within thepipes contains a rim with elevation at the storage elevation, serving as the overflow elevation. 2. a. If claiming vested rights, identify the supporting documents provided and the date they were approved: ❑ Approval of a Site Specific Development Plan or PUD Approval Date: ❑ Valid Building Permit Issued Date: ❑ Other: Date: b.If claiming vested rights, identify the regulation(s) the project has been designed in accordance with: ❑ Coastal SW -1995 ❑ Ph II - Post Construction 3. Stormwater runoff from this project drains to the Pasquotank River basin. 4. Total Property Area:1.03 acres 5. Total Coastal Wetlands Area: 0 acres 6. Total Surface Water Area: 0 acres 7. Total Property Area (4) -Total Coastal Wetlands Area (5) -Total Surface Water Area (6) = Total Project Area':1.03 acres Total project area shall be calculated to exclude the following the normal pool of imyyou�nded structures, the area between the banks of streams and rivers, the area below the Normal Higgh� Water (NHW) line or Mean High Water (MHW) line, and coastal wetlands landward from the NHW (or MHW) line. The resultant project area is used to calculate overall percent built upon area (BUA). Non -coastal wetlands landward of the NHW (or MHW) line may be included in the total project area. 8. Project percent of impervious area: (Total Impervious Area / Total Project Area) X 100 = 6 r 2 % 9. How many drainage areas does the project have?1 (For high density, count I for each proposed engineered stormwater BMP. For low density and other projects, use I for the whole property area) 10. Complete the following information for each drainage area identified in Project Information item 9. If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. Basin Information Drainage Area 1 Drainage Area _ Drainage Area _ Drainage Area _ Receiving Stream Name Kitty Hawk Bay Stream Class * SC Stream Index Number * 30-19 Total Drainage Area (so 45,000 On -site Drainage Area (so 45,000 Off -site Drainage Area (so 0 Pro used Impervious Area** (so 27,981 % Impervious Area** total 62.2% Impervious— Surface Area Drainage Area 1 Drainage Area _ Drainage Area _ Drainage Area _ On -site Buildings/Lots (so 0 On -site Streets (so 0 On -site Parking (so 27,301 On -site Sidewalks (so 680 Other on -site (so 0 Future (so 0 Off -site (so 0 Existing BUA*** (so 0 Total (so: 27,981 * Stream Class and Index Number can be determined at: ham://portal.ncdenr.org/web/wq/ys/csu/classifications * Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. **` Report only that amount of existing BUA that will remain after development. Do not report any existing BUA that is to be removed and which will be replaced by new B UA. 11. How was the off -site impervious area listed above determined? Provide documentation. Field observation Proiects.in Union County: Contact DWQ Central Office staff to check if the project is located within a Threatened & Endangered Species watershed that may be subject to more stringent stormwater requirements as per NCAC 02B .0600. V. SUPPLEMENT AND O&M FORMS The applicable state stormwater management permit supplement and operation and maintenance (O&M) forms must be submitted for each BMP specified for this project. The latest versions of the forms can be downloaded from http://portal.ncdenr.oriz/web/wq/ws/su/bmp-manual. VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below. A detailed application instruction sheet and BMP checklists are available from http://portal.ncdenr.org/web/wg/ws/su/statesw/forms dots. The complete application package should be submitted to the appropriate DWQ Office. (The appropriate office may be found by locating project on the interactive online map at http://portal.ncdenr.org/web/wq/ws/su/maps.) Please indicate that the following required information have been provided by initialing in the space provided for each item. All original documents MUST be signed and initialed in blue ink. Download the latest versions for each submitted application package from hU://portal.ncdenr.org/web/wq/ws/su/statesw/forms does. Initials 1. Original and one copy of the Stormwater Management Permit Application Form. mo'\ 2. Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants t` j c'L Form. (if required as per Part VII below) 3. Original of the applicable Supplement Form(s) (sealed, signed and dated) and O&M KSN\ agreement(s) for each BMP. 4. Permit application processing fee of $505 payable to NCDENR. (For an Express review, refer to M5h http://www.envhelp.org/pap:es/onestopexpress.htmifor information on the Express program and the associated fees. Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required application meeting.) 5. A detailed narrative (one to two pages) describing the stormwater treatment/managementfor the project. This is required in addition to the brief summary provided in the Project Information, item 1. 6. A USGS map identifying the site location. If the receiving stream is reported as class SA or the receiving stream drains to class SA waters within 1/2 mile of the site boundary, include the mile radius on the map. tnsa^ 7. Sealed, signed and dated calculations. _ 8. Two sets of plans folded to 8.5" x 14" (sealed, signed, & dated), including: _ a. Development/Project name. b. Engineer and firm. c. Location map with named streets and NCSR numbers. d. Legend. e. North arrow. f. Scale. g. Revision number and dates. h. Identify all surface waters on the plans by delineating the normal pool elevation of impounded structures, the banks of streams and rivers, the MHW or NHW line of tidal waters, and any coastal wetlands landward of the MHW or NHW lines. • Delineate the vegetated buffer landward from the normal pool elevation of impounded structures, the banks of streams or rivers, and the MHW (or NHW) of tidal waters. i. Dimensioned property/project boundary with bearings & distances. j. Site Layout with all BUA identified and dimensioned. k. Existing contours, proposed contours, spot elevations, finished floor elevations. 1. Details of roads, drainage features, collection systems, and stormwater control measures. m. Wetlands delineated, or a note on the plans that none exist. (Must be delineated by a qualified person. Provide documentation of qualifications and identify the person who made the determination on the plans. n. Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations. o. Drainage areas delineated (included in the main set of plans, not as a separate document). p. Vegetated buffers (where required). 9. Copy of any applicable soils report with the associated SHWT elevations (Please identify _ elevations in addition to depths) as well as a map of the boring locations with the existing elevations and boring logs. Include an 8.5"x11" copy of the NRCS County Soils map with the project area clearly delineated. For projects with infiltration BMPs, the report should also include the soil type, expected infiltration rate, and the method of determining the infiltration rate, (Infiltration Devices submitted to WiRO: Schedule a site visit for DWQ to verify the SHVVf prior to submittal, 796-7378.1 10. A copy of thee most most current property deed. Deed book: 51� � Page No: 6% 11. For corporations and limited liability corporations (LLC): Provide documentation from the NC _ fA5 t"x Secretary of State or other official documentation, which supports the titles and positions held by the persons listed in Contact Information, item la, 2a, and/or 3a per NCAC 2H.1003(e). The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State, otherwise the application will be returned. h!W://www.secreta!y.state.nc.us/Corporations/CSearch.aspx VII. DEED RESTRICTIONS AND PROTECTIVE COVENANTS 1NS J1 For all subdivisions, outparcels, and future development, the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot. If lot sizes vary significantly or the proposed BUA allocations vary, a table listing each lot number, lot size, and the allowable built -upon area must be provided as an attachment to the completed and notarized deed restriction form. The appropriate deed restrictions and protective covenants forms can be downloaded from http://portal.ncdenr.orit/web/wq/ws/su/statesw/forms does. Download the latest versions for each submittal. In the instances where the applicant is different than the property owner, it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded. By the notarized signature(s) below, the permit holder(s) certify that the recorded property restrictions and protective covenants for this project, if required, shall include all the items required in the permit and listed on the forms available on the website, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DWQ and that they will be recorded prior to the sale of any lot. VIII. CONSULTANT INFORMATION AND AUTHORIZATION Applicant: Complete this section if you wish to designate authority to another individual and/or firm (such as a consulting engineer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional information). Consulting Engineer:Michael 1. Morway, PE Consulting Firm: Albemarle & Associates, Ltd. Mailing Address:PO Box 3989 City:Kill Devil Hills Phone: (252 ) 441-5480 Email:mikem@albemarleassociates.com State:NC Zip:27948 Fax: (252 ) 441-0965 IX. PROPERTY OWNER AUTHORIZATION (if Contact Information, item 2 has been filled out, complete this section) I, (print or type name of person listed in Contact Information, item 2a) Nicholas Nuzzi , certify that I own the property identified in this permit application, and thus give permission to (print or type name of person listed in Contact Information, item la) Geor-Qe Pitsilides with (print or type name of organization listed in Contact Information, item la) Pitco 1, LLC to develop the project as currently proposed. A copy of the lease agreement or pending property sales contract has been provided with the submittal, which indicates the party responsible for the operation and maintenance of the stormwater system. As the legal property owner I acknowledge, understand, and agree by my signature below, that if my designated agent (entity listed in Contact Information, item 1) dissolves their company and/or cancels or defaults on their lease agreement, or pending sale, responsibility for compliance with the DWQ Stormwater permit reverts back to me, the property owner. As the property owner, it is my responsibility to notify DWQ immediately and submit a completed Name/Ownership Change Form within 30 days; otherwise I will be operating a stormwater treatment facility without a valid permit. I understand that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statue 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $25,000 per day, pursuant to NCGS 143-215.6. Signature: Date: 3/1V�Zo�� I,',a:,a Ak . C v//�� cw a Notary Public for the State of rlK , Countyof 1 h r do hereby certify that lr las `xL h zz: personally appeared before me this I/ Aday of _lbaxcl% Jalf _, "d—ac-kRowledge the due ex e ion of the application for a stormwater permit. Witness my hand and official seal, V)�, PATRICIA M. GRAY . NOTARY PUBLIC ARE.000NTY, NC SEAL My commission expires As the legal property owner 1 acknowledge, understand, and agree by my signature below, that if my designated agent (entity listed in Contact Information, item 1) dissolves their company and/or cancels or defaults on their lease agreement, or pending sale, responsibility for compliance with the DWQ Stormwater permit reverts back to me, the property owner. As the property owner, it is my responsibility to notify DWQ immediately and submit a completed Name/Ownership Change Form within 30 days; otherwise I will be operating a stormwater treatment facility without a valid permit. I understand that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statue 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $25,000 per day, pursuant to NCGS 143-215.6. Signature: a Notary Public for the State of , County of Lie hereby certify that before me this _ day of personally appeared and acknowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, SEAL. My commission expires X. APPLICANT'S CERTIFICATION 1, (print or hype name of person listed in Contact Information, item In) George Pitsilides certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of the applicable stormwater rules under 15A NC�1C 2H .1000, SL 2006-246 (Ph. II - Post Construction) or SL 2008-211. Signature: this a stormwater permit. Date: 3 -N- / Wli , a N }ta�r�y�Public f the State of V ' M'k , County of -, do ereby certify that �� / 6 personally appeared of , an acMM eexecution of the application for Witness my hand and official seal, SISAL My commission expires 1 -✓ I - W I I Form SWU-101 Version 07Jun2010 Page 6 of 6 5VJ! 111 03 rz ` Permit NEO XPRESS MAR `31 P ®T! STORMWATER MANAGEMENT PERMIT APPLICATION FORM NC DLL WDENR 401 CERTIFICATION APPLICATION FORM INFILTRATION BASIN SUPPLEMENT This form must be filled out, printed and submitted. The Required Items Checklist (Part III) must be printed, filled out and submitted along with all of the required information. I. PROJECT INFORMATION Project Name Pitoo 1, LLC - Parking Lot Contact Person Michael J. Morway, PE Phone Number 252441-2113 Date 3-Mar-11 Drainage Area Number 1 II. DESIGN INFORMATION Site Characteristics Drainage area 45,000.00 fl= ✓ Impervious area 27,981.00 f? ✓ Percent impervious 0.62 % / Design rainfall depth 1.50 in Peak Flow Calculations 1-yr, 24-hr rainfall depth 3.40 in 1-yr, 24-hr intensity 0.14 inmr Pre -development 1-yr, 24-hr discharge 0,04 fl'/sec Post -development 1-yr, 24-hr discharge 0.10 ff'Isec Pre/Post 1-yr, 24-hr peak flow control 0.10 ff'Isec Storage Volume: Non -SA Waters Minimum design volume required 3,429.00 ft' Design volume provided 6,966.00 ft3 t/ OK for non -SA waters Storage Volume: SA Waters 1.5' runoff volume rile ft3 Pre -development 1-yr, 24-hr runoff volume n3 Post -development 1-yr, 24-hr runoff volume f(3 Minimum required volume rya Volume provided 113 Soils Report Summary Soil type CrB Infiltration rate 20.00 in/hr SHWT elevation 4.10 fmsl Basin Design Parameters Drawdown time 1.00 days OK Basin side slopes 3.00 :1 OK Basin bottom elevation 6.10 fmsl OK Storage elevation 7.10 fmsl Storage Surface Area 8,325. 00 ftz ✓ Top elevation 7.40 fmsl Basin Bottom Dimensions Basin length 376.00 It Basin width 14.00 ff Bottom Surface Area 5,607.00 ft2✓ Form SW401-Infiftration Basin-Rev.4 Parts 1. & 11. Design Summary, Page 1 of 2 Permit (to be pmdtled by DWQ) Additional Information Maximum runoff to each inlet to the basin? Length of vegetative filter for overflow Distance to structure Distance from surface waters Distance from water supply well(s) Separation from impervious soil layer Naturally occuring soil above shwt Bottom covered with 4-in of clean sand? Proposed drainage easement provided? Capures all runoff at ultimate build -out? Bypass provided for larger storms? Pretreatment device provided 1.90 ac-in 30.00 It <15 It 10.00 ft <100 It <2 ft 2.00 ft y (Y or N) n/a (Y or N) y (Y or N) n/a (Y or N) OK (-ra-cwt_ OK 5,,A Wr OK Too close to surface waters OK OK OK OK OK OK OK lE'Yr%T OQAIN Ca OrTcr , Form SW401-Infiltration Basin-Rev.4 Parts 1. & II. Design Summary, Page 2 of 2 Permit No.S-V\/ 1 (( h3 c-y (to be provided by DWQ) III. REQUIRED ITEMS CHECKLIST Please indicate the page or plan sheet numbers where the supporting documentation can be found. An incomplete submittal package will result in a request for additional information. This will delay final review and approval of the project. Initial in the space provided to indicate the following design requirements have been met. If the applicant has designated an agent, the agent may initial below. If a requirement has not been met, attach justification. Pagel Plan Initials Sheet No. i� C20 1. Plans (1" - 50' or larger) of the entire site showing: - Design at ultimate build -out, - Off -site drainage (if applicable), - Delineated drainage basins (include Rational C coefficient per basin), - Basin dimensions, - Pretreatment system, - High flow bypass system, - Maintenance access, - Proposed drainage easement and public right of way (ROW), - Overflow device, and - Boundaries of drainage easement. MS{� C2OI 2, Partial plan (1" = 30' or larger) and details for the infiltration basin showing: - Bypass structure, - Maintenance access, - Basin bottom dimensions, - Basin cross-section with benchmark for sediment deanout, - Flow distribution detail for inflow, - Vegetated filter, and - Pretreatment device. r CEO 1 3. Section view of the infiltration basin (1" = 20' or larger) showing: - Pretreatment and treatment areas, and - Inlet and outlet structures. MSr UO_ 4. A table of elevations, areas, incremental volumes & accumulated volumes to verify the volume provided. �9 5. A soils report that is based upon an actual field investigation, soil borings, and infiltration tests. The results of the soils report must be verified in the field by DWQ, by completing & submitting the soils investigation request form. County soil maps are not an acceptable source of soils information. MS{� C90 6. A construction sequence that shows how the intitirabon basin will be protected from sediment until the entire drainage area is stabilized. Kt\ - 7. The supporting calculations. t� (1 8. A copy of the signed and notarized operation and maintenance (0&M) agreement. 9. A copy of the deed restrictions (if required). Form SW401-Infiltration Basin-Rev.4 Page 1 of 1 Part III. Required Items Checklist, Page 1 of 1 Permit Number: 5 VV -I 1 l 0 3 1 "L EXPRE?4 �If����aS (to be provided by DWQ) SS Drainage Area Number: MAR 31 201Wiltration Basin Operation and Maintenance Agreement NC DEER I will keep a maintenance record on this BMP. This maintenance record will be kept in a log in a known set location. Any deficient BMP elements noted in the inspection will be corrected, repaired or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the removal efficiency of the BMP. Important maintenance procedures: — The drainage area will be carefully managed to reduce the sediment load to the infiltration basin. — Immediately after the infiltration basin is established, the vegetation will be watered twice weekly if needed until the plants become established (commonly six weeks). — No portion of the infiltration basin will be fertilized after the initial fertilization that is required to establish the vegetation. — The vegetation in and around the basin will be maintained at a height of approximately six inches. After the infiltration basin is established, it will be inspected once a quarter and within 24 hours after every storm event greater than 1.0 inches (or 1.5 inches if in a Coastal County). Records of operation and maintenance will be kept in a known set location and will be available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. BMP element: Potentialproblem: How I will remediate theproblem: The entire BMP Trash/debris is present. Remove the trash/debris. The perimeter of the Areas of bare soil and/or Regrade the soil if necessary to infiltration basin erosive gullies have formed. remove the gully, and then plant a ground cover and water until it is established. Provide lime and a one-time fertilizer application. The inlet device: pipe or The pipe is clogged (if Unclog the pipe. Dispose of the swale applicable). sediment off -site. The pipe is cracked or Replace the pipe. otherwise damaged (if applicable). Erosion is occurring in the Regrade the swale if necessary to swale (if applicable). smooth it over and provide erosion control devices such as reinforced turf matting or riprap to avoid future problems with erosion. D,.— orvnni L.C.i,....ti.... D....;.. nP.AA D,.., a BMP element: Potentialproblem: How I will remediate theproblem: The forebay Sediment has accumulated Search for the source of the and reduced the depth to 75% sediment and remedy the problem if of the original design depth. possible. Remove the sediment and dispose of it in a location where it will not cause impacts to streams or the BMP. Erosion has occurred or Provide additional erosion riprap is displaced. protection such as reinforced turf matting or riprap if needed to prevent future erosion problems. Weeds are present. Remove the weeds, preferably by hand. If pesticides are used, wipe them on the plants rather than spraying. The main treatment area A visible layer of sediment Search for the source of the has accumulated. sediment and remedy the problem if possible. Remove the sediment and dispose of it in a location where it will not cause impacts to streams or the BMP. Replace any media that was removed in the process. Revegetate disturbed areas immediately. Water is standing more than Replace the top few inches of filter 5 days after a storm event. media and see if this corrects the standing water problem. If so, revegetate immediately. If not, consult an appropriate professional for a more extensive repair. Weeds and noxious plants are Remove the plants by hand or by growing in the main wiping them with pesticide (do not treatment area. spray). The embankment Shrubs or trees have started Remove shrubs or trees to grow on the embankment. immediately. An annual inspection by an Make all needed repairs. appropriate professional shows that the embankment needs repair. The outlet device Clogging has occurred. Clean out the outlet device. Dispose of the sediment off -site. The outlet device is damaged Repair or replace the outlet device. The receiving water Erosion or other signs of Contact the NC Division of Water damage have occurred at the Quality 401 Oversight Unit at 919- outlet. 733-1786. c..—cwnni 0.-;-ll %l n,...Y n.--I—F1 Permit Number: (to be provided by DWQ) 1 acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Projecl name:Pitco 1, LLC - Parking Lot BMP drainage area number: Print name:George Pitsilides Title:Manaeer Address:1956 Laskin Road. Virginia Beach, VA, 23454 Note: The legally responsible party should not be a homeowners association unless more than 50%of the lots have been sold and a resident of the subdivision has been named the president. Public for the State of V V lvuvU — , County ol'AMM& MAW do hereby certify that��Q��t personally appeared before me this 0 D day of %a , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements. Witness my hand and official seal, My commission expires 1' �-VUt Form SW401-Infiltration Basin O&M-Rev.3 Page 3 of') /1 STORMWATER SUBMITTAL REQUIREMENTS INFILTRATION/EXFILTRATION SYSTEMS Basins and Trench Objective A. Collect all runoff from all BUA (proposed and/or existing and/or offsite) as the case may be, by any means including piping or swales, and direct it to the infiltration system. B. Check the proposed basin/ trench design to make sure it meets or exceeds the minimum design criteria for design storm, volume and drawdown. II. What makes up a complete infiltration basin / trench application package? A. Two sets of sealed, signed & dated layout & grading plans with appropriate details. B. Completed application with supplement(s), SWU-101, SW401-Infiltration Trench, SW401- Infiltration Basin, and inspection and maintenance agreements. C. Deed restriction document, if applicable. (subdivisions & projects with out parcels) D. Sealed, signed & dated calculations. E. A soils report containing information in regard to the soil type, boring locations, seasonal high water table elevation and expected infiltration rate. F. Chlorides test results must be provided if the project is within Yz mile of SR waters (Phase 11). (This is only required to test out of SR water treatment requirements) III. BIMS entry (for DWQ use only) Enter & track application acknowledged date, review date, add info requested/received dates, permit issue dates, and drainage area info. Best done after the add info letter is written and before sending permit up for signature. IV. Shell documents (for DWQ use only) Permit shells: s:\wqs\stormwater\shell\shighcominbasin S:\wqs\stormwater\shells\highcomintrench s:\wqs\stormwater\shel Is\hig hsubi n basin s:\wqs\stormwater\shells\highsubintrench Calculations: s:\wqs\stormwater\excel spread sheets\inbasin s:\wqs\stormwater\excel spread sheets\intrench V. Review Procedure- look for consistency between the various elements of the package- application, plan and calculations. A. AP,P/LICATION 1. V Original signatures are required. Photocopied signatures cannot be accepted. 2.A completed infiltration basin or infiltration trench supplement, one for each proposed system. A signed, dated and notarized Inspection and Maintenance Agreement for each proposed system with an original signature. 3. The elevations, areas and volumes reported on the supplement match up to the ✓ numbers used in the calculations and shown on the plan details. 4. ✓Built -upon areas are reported in square feet in Section 111.6. 5. Receiving stream name and classification. 6. ✓Section 111.6 is filled in -cannot be left blank. One column must be filled in for each Vproposed infiltration basin or trench. 7. If the applicant is a corporation, partnership or LLC, look it up on the Secretary of State Corporations Database. Make sure corporation is spelled correctly (capitalization and punctuation matter) and that the person signing the application is at least a vice- president in the corporation, a General Partner in the partnership, a member in a member -managed LLC, or the manager of a manager -managed LLC. Need documentation to support if the Articles of Incorporation do not list the members or managers of the LLC. If an agent signs, then a letter of authorization is needed from the 8Npresident, vice president, general partner, member or manager. ) For subdivided projects, a signed and notarized deed restriction statement must be provided. 9. Soils report with the SHWT, Soil type and expected infiltration rate. Infiltration Basin & Trench, cont. B. CALCULATIONS 1. V The basin or trench must draw down within 5 days. Spray irrigation is not acceptable as the sole means of drawdown. 2. (/ The design storm is 1.5" if the project is subject to Phase II or is sited within '/z mile of and draining to SA waters. The design storm for projects subject to Phase II sited within '/z mile of and draining to SR waters must treat the difference between the pre and post development conditions for the 1-yr 24-hr storm. Otherwise, use 1" design ✓ storm. 3. Report the bottom surface area. 4. Report the surface area at the overflow elevation. 5. v Show the calculation for the minimum required volume. 6. ✓ Provide a table of elevations, areas, incremental volumes and accumulated volumes to demonstrate that the minimum required volume has been provided. 7. V Calculations are signed, sealed & dated. 8. ✓ Report the Drainage Area and Built -upon area for each basin or trench. 9. V The seasonal high water table must be at least 24" below the proposed bottom elevation of the system. For Phase II projects, at least 12" of this must be in naturally occurring soils. 10. All runoff in excess of the design storm must bypass to a vegetated filter prior to entering the basin or trench. If the system is designed to store a larger design storm (generally 2-3 times the minimum), the requirement for an offline bypass can be waived. Please contact the Division to determine what design storm is appropriate for the project. / / / Infiltration Basin & Trench, cont. C. PLANS - Plan sheets should be kept to a minimum. For small commercial single basin projects, the plan set could consist of only 2 or 3 sheets, layout, grading and details. For larger projects, show as much information as possible on as few sheets as possible, without cluttering them up. 1. ✓ Development/Project Name 2.✓Engineer name and firm. 3.✓Legend 4. ✓North Arrow 5. ✓Location Map with nearest intersection of two major roads shown. Major road is any 1, '/2, or 3 digit NC, US or interstate highway. 6. Scale- standard engineering scale, no off-the-wall stuff. 7. Date 8. v//Revision number and date, if applicable. 9. Y Original contours, proposed contours, spot elevations, finished floor elevations, pipe ✓inverts, Swale inverts, etc. 10. Existing drainage (piping, swales, ditches, ponds, etc.), including off -site. Include a map delineating the offsite drainage areas. 11.✓Property/Project boundary lines, bearing &distances. 12.�Mean High Water Line or Normal High Water Line, if applicable. 13. Drainage easement locations shown on the plans along with their width. 14.✓Wetlands delineated, or a note on the plans that none exist. Provide a copy of the wetlands delineation map signed by the Corps of Engineers, or have the applicant include a copy of the unsigned delineation map submitted to the Corps. Infiltration systems may not be located in wetlands unless a permit to fill those wetlands has been nts. /obtained and the soils meet the SHWT and hydraulic conductivity requireme 15V Details for he roads, parking, cul-de-sacs, including sidewalk width, radii, dimensions & 16�slopes. Apartment / Condo development- provide a typical building footprint with dimensions, and note all concrete and wood deck areas. 17. The drainage area for each basin or trench is clearly delineated and numbered to match up to the calculations and supplement. Drainage area delineation is best done as a separate plan sheet. 18 ✓A basin section detail showing bottom and storage elevations, 3:1 side slopes. The side slopes of an infiltration basin are not restricted to vegetation. They may be hardened with rock, timber, concrete, decorative brick, etc. 19WA trench section detail with the perforated pipe diameter, filter fabric wrapped around 2ethe pipe and around the trench, trench height and width, rock fill type. h—Clf using a pre-fab chamber structure, provide details of the chamber, including model #, /length, width, chamber volume and number of chambers being used. 21./ A bypass structure detail is provided showing a trash rack with :56" square openings, and the necessary bypass weir or pipe elevation. Several types of bypass structure designs are acceptable. 22�./Dimensions for each line and arc formed by the bottom contour of an infiltration basin. 23. All runoff in excess of the design storm must pass through a vegetated filter prior to being discharged into the receiving stream. The filter must be 50' long for SA waters /and 30' long for non -SA waters. 24All infiltration systems must be located at least 50' from the MHW line of surface waters. 26XVegetation is specified for basin slopes not being hardened. Weeping Love Grass is not suitable as a permanent vegetated cover for side slopes. 26.✓All roof drainage must be directed to the system. Show the roof drain collection piping on the plans. This is especially necessary for projects where the buildings back up the property lines where roof drainage may leave the site prior to going through the system. 2V Monitoring wells may be required on a case -by -case basis.