Loading...
HomeMy WebLinkAboutSW7080414_HISTORICAL FILE_20080418STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD Akpw JA NCDENR For DENR Use ONLY North Carolina Department of Environment and Reviewor: fL Ar Natural Resources Submit: Request for Express Permit Review FILL-IN all the Information below and CHECK the Permit(a) you are requesting for express review. FAX or Coordinator along with a completed DETAILED narrative, site plan (PDF file) and vicinity Mao (same items of the project location. Please include this form in the application package. • Asheville Region -Alison Davidson 828.296.4698;a11son.devldsonCDncmall.net • Fayetteville or Raleigh Region -David Lee 919-7914203; david.1900ncmail.nef • Mooresville & -Patrick Grogan 704-883-3772 or patrick.orogan(awcmail.net • Washington Region -Lyn Hardison 252-946-9215 or Ivn.hardisonCdncmall.net • Wilmington Region -Janet Russell 910-350.2004 or lanet.russeliftricmail.net NOTE. Project application received after 12 noon will be stamped in the following work day Time: � nn Confirm: �-ASty EXPRESS APR 18 20,,,, Project Name: STATE FARM INSURANCE OFFIC E County: CRAVEN �� ®��� Applicant: _ Company: COMER FAMILY, LLC Address: 107 GREENFIELD HEIGHTS BOULEVARDCity: HAVELOCK, State: NC Zip: 28532 Phone:252444-1700 Fax: Email: _ Project Drains into CEDAR CREEK waters — Water classification SC: SW, NSW (for classification see- hftp://h2o.enr.state.nc.us/bims/reporistrepoftsWB.html) Project Located in NEUSE River Basin. Is project draining to class ORW waters? N , within''/2 mile and draining to class SA waters N or within 1 mile and draining to class HOW waters? N Engineer/Consultant: JOSEPH C. AVOLIS, P.E. Company: AVOLIS ENGINEERING, RA. Address: P.O. BOX 15564 City: NEW BERN, State: NC Tip: 28561 Phone: 252-633-68 Fax::252-633.6507 Email: AVOLISENGaLPMONLINE. NET (Check all that apply) ❑ Scoping Meeting ONLY ❑ DWQ, ❑ DCM, ❑ DLR, ❑ OTHER: ❑ Stream Origin Determination: _ # of stream calls — Please attach TOPO map marking the areas in questions ® State Stormwater ❑ General ❑ SFR, ❑Bkhd & Bt Rmp, ❑ Clear & Grub, ❑ Utility ❑ Low Density ❑ Low Density -Curb & Gutter _ # Curb Outlet Swales ❑ Off -site [SW _ (Provide permit #)] ® High Density -Detention Pond 1 # Treatment Systems ❑ High Density -Infiltration _ #Treatment Systems ❑ High Density -Bio-Retention _ # Treatment Systems [:1High Density—Stonmwater Wetlands _ # Treatment Systems ElHigh Density -Other _ # Treatment Systems ❑ MODIFICATION ❑ REVISIONS SW _ (Provide permit #) ❑ Coastal Management ❑ Excavation & Fill ❑ Bridges & Culverts ❑ Structures Information ❑ Upland Development ❑ Marina Development ❑ Urban Waterfront ❑ Land Quality ❑ Erosion and Sedimentation Control Plan with _ acres to be disturbed.(CK # (for DENR use)) WETLANDS QUESTIONS MUST BE ADDRESSED BELOW ❑ Wetlands (401): Check all that apply Isolated wetland on Property ❑ Yes N No Wetlands on Site ❑ Yes N No Buffer Impacts: N No ❑ YES: acre(s) Wetlands Delineation has been completed: N Yes ❑ No Minor Variance; N No ❑ YES US ACOE Approval of Delineation completed: ❑ Yes N No Major General Variance N No ❑ YES 404 Application in Process w/ US ACOE: ❑ Yes N No 401 Application required: ❑Yes N No It YES, ❑ Regular Permit Received from US ACOE ❑ Yes N No Perennial, Blue line stream, etc on site ❑ yes N No For DENR use only I Fee SDlit for multiple permits: [Check # 1 R?�d 1 Total Fee Amount $ 4D0 0 SUBMITTAL DATES Fee SUBMITTAL DATES Fee MA $ Variance Me]; Min)$ SW HD, ❑ LD, ❑ Gen $ 4 DDD 401: $ LQS $ 1 Stream Deter,_ $ NCDENR EXPRESS January 2008 North Carolina Secretary of State http://www. secretary. state. nc. us/corporations/Corp.aspx?Pitemld=... Elaine F. Marshall Secretary CORPORATIONS Corporations Home Search By Corporate Name Search For New Corporation Search By Registered Agent Important Notice Corporations FAQ Homeowners' Association FAQ Tobacco Manufacturers Dissolution Reports Non -Profit Reports Verify Certification Online Annual Reports LINKS & LEGISLATION KBBE B2B Annual Reports SOSID Number Correction 2001 Bill Summaries 1999 Senate Bills Annual Reports 1997 Corporations 1997 Register for E-Procurement Dept. of Revenue ONLINE ORDERS Start An Order New Payment Procedures CONTACT US Corporations Division Secretary of State's web site TOOLS Secretary of State Home Secretary of State Site Map Click here to: North Carolina DEPARTMENT OF THE SECRETARY OF STATE PO Box 29622 Raleigh, INC 27626-0622 (919)607-2000 Date: 4/18/2008 View Document Filings I Sign Up for E-Notifications I nA Print apre-populated Annual Report Form I Annual Report Count 1 File an Annual Report I Corporation Names Name Name Type NC COMER Legal FAMILY, LLC Limited Liability Company Information SOSID: 1016192 Status: Current -Active Date Formed: 12/10/2007 Citizenship: Domestic State of Inc.: Duration: Registered Agent Agent Name: Registered Office Address: Registered Mailing Address: Principal Office Address: NC 12/31 /2035 Comer. Donna H. 107 Greenfield Heights Blvd. Havelock NC 28532 107 Greenfield Heights Blvd. Havelock NC 28532 107 Greenfield Fits Blvd Havelock NC 28532 1 of 2 4/18/2008 9:32 AM FROM FAX NO. Feb. 11 2002 04:25PN P3 c4 wAviTf�.g��O; Form CS-SSO Sower Overflow Reporting Form ColleetWn Sy PART I I ANSWER THE FOLLOWING QUESTIONS FOR EACH RELATED CAUSE CHECKED IN PART I OF THIS FORM AND INCLUDE THE APPROPRIATE DOCUMENTATION AS REQUIRED OR DESIRED +(` COMPLETE ONLY THOSE SECTIONS PERTAINING TOITHE CAUSE OF THE SSO AS CHECKS! N PART I In the check boxes below, NA = Not Applicable and NE = Not I=valusted A HARDCOPY OF THIS FORM SHOULD BE SUBMITTED TO THE APPROPRIATE DWQ REGIONAL OFFICE UNLESS IT HAS BEEN SUBMITTED ELECTRONICALLY THROUGH THE ONLINE REPORTING SYSTEM Severe Natural Condition hum ane tornado etc. t, Desa'ibe the "severe natural contlioon' In stall. How much advar+ce warning did you have an at eCicn9 WorB taken in prepareUan for the ont7 Comments: :r C7reas9 Documentation suG1 as cleanl ins ions enforcernen actions ast overflow re orts educational maten I and dlstnbutio data etc. should be available upon request) When wee the last time this specific line (or wet well} was Clain 7 ,dam;.,,1 Le&jV * 1 toT Va afintemaptors? LIIyeN__r Na❑NA❑NE -- Do you have an enforceable grease ordinance that requires new Or.. g .re89e P Have there been recent 09paesons and/or enforcement actions on n rby fasfeurent9 Of Other EIVJR Ne❑NA❑NE nonresidential grease Contributors? '/i • "t Vfi' Ir , Explain. rt—'l1 Have there bean othar SSOs or blockages in this a that wore olse caused by grease? Yeau No ❑NA ❑NE Whan? J7.67t/o 4 1 If yes, describe tfrem: r r SgmM+F OSGR 11�-� Hava cleaning and Imp ons ever bean increased at this location? Yent.:r No ❑NA ❑NE Explaln. CS-SSO Forth October 9, 2003 Page 2 AVOLIS ENGINEERING, P.A. L-77.3 P.O. Box 15564 • New Bern, North Carolina 28561 • (252) 633-0068 April 16, 2008 APR 18 2008 Mr. At Hodge Environmental Engineer`p�n ent�® NCDENR - Water Quality Section `t �V 943 Washington Square Mall Washington, NC 27889 RE: State Farm Insurance Office U.S. 70 Service Road/Stratford Drive, Havelock, Craven County, North Carolina AE Project No. 08009 Dear Al: Enclosed please find the following for the above -referenced project for your review and approval: • Stormwater Permit with Narrative (Original and One Copy) • Project Plans (2 Copies) • Stormwater Calculations (2 Copies) Soils Report (Two Copies) • $4,000 Permit Fee It is requested that you review the permit package at your earliest convenience. Should you have any questions relating to this matter or need any additional information, please do not hesitate to call. Sincerely, lis, P.E. Google Maps http://maps. goog le.com/maps? ie=U TF8&oe=utf-8&c I ient=firefox-a& h... Google- maps @2007 G Get Google Maps on your phone Texttheword "GMAPS"to 466453 loft 4/17/2008 3:50 PM u , u' : '.1• - z. STORMWATER SUBMITTAL REQUIREMENTS WET DETENTION POND Objective A. V Collect all runoff from all BUA (proposed and/or existing and/or offsite) as the case may be, by any means including piping or swales, and direct it to the pond. B. V Check the proposed pond design to make sure it meets or exceeds the minimum design criteria for surface area, volume and drawdown. II. What makes up a complete wet detention pond application package? A. Two sets of sealed, signed & dated layout & grading plans with appropriate details. J (Additional sets of plans may be requested for protects in certain counties) B. Completed application with supplement(s), SWU-101, SW401-Wet Pond, and inspection and maintenance agreements. C, 1 Deed restriction document, if applicable (for subdivisions & projects with out parcels) D. Sealed, signed & dated calculations. E. Estimated seasonal high water table elevation at all pond locations. F.0-Chlorides test results must be provided if the project is within''/2 mile of SR waters (Phase 11). (This is only required to test out of SR water treatment requirements) III. BIMS entry (for DWQ use only) Enter & track application acknowledged date, review date, add info requested/received dates, permit issue dates, and drainage area info. Best done after the add info letter is written and before sending permit up for signature. IV. Shell documents (for DWQ use only) Permit shells: s:\wqs\stormwater\shells\highcompond s:\wqs\stormwater\shells\highsubpond s:\wqs\stormwater\shells\HDhybrid Spreadsheet: s:\wqs\stormwater\excel spreadsheets\pond VI. Review Procedure A. APPLICATION 1. �.A An original signature is required. Photocopied signatures cannot be accepted. 2. completed wet detention pond supplement and a signed, dated and notarized wet detention pond Inspection and Maintenance Agreement with an original signature. 3. V/The numbers on the supplement match up to the numbers used in the calculations and / shown on the plan details. 4. vVV Built -upon areas are reported in square feet in Section 111.6. 5. Receiving stream name and classification. This is important because in the non -Phase II counties, a wet pond cannot be used on a project that is within'h mile of and draining /�to SA waters. For Phase I I, a wet pond is allowed within '/z mile of SA waters. 6. ✓ Section 111.6 is filled in -cannot be left blank. One column must be filled in for each / proposed wet pond. 7. t/ If the applicant is a corporation, partnership or LLC, look it up on the Secretary of State Corporations Database. Make sure corporation is spelled correctly (capitalization and punctuation matter) and that the person signing the application is at least a vice- president in the corporation, a General Partner in the partnership, a member in a member -managed LLC, or the manager of a manager -managed LLC. Need documentation to support if the Articles of Incorporation do not list the members or managers of the LLC. If an agent signs, then a letter of authorization is needed from the 8.0 president, vice president, general partner, member or manager. For subdivided projects, a signed and notarized deed restriction statement must be provided. Wet Detention Pond, cont. B. CALCULATIONS 1. ✓ The orifice is sized based on drawing down the calculated minimum volume in 2-5 days. The average head to use in the orifice equation is approximately one-third of the distance between the permanent pool elevation (PPE) and the elevation of the next available outlet above the permanent pool. The elevation of the next available outlet must be either the elevation where the minimum volume is provided, or it can be higher. The temporary pool elevation (TPE) to report on the supplement will be the elevation of the next available outlet above the PPE. The temporary pool volume (TPV) to report on the supplement is the volume between the specified PPE and the ��{{ TPE. 2.1"�kor Phase II projects that are within''/3 mile of and draining to SR waters, the difference in runoff from the predevelopment and post -development conditions for 3 u)the 1 year 24 hour storm must be controlled and treated. ,kFor Phase II projects, the discharge rate leaving the pond can be no more than the pre -development discharge rate for the 1 year 24 hour storm. For Phase II projects draining to SA water, no discharge to surface waters may occur from wet ponds. The discharge leaving the orifice must be effectively infiltrated prior to ✓reaching surface waters. 5. The average pond depth is the permanent pool volume divided by the permanent pool surface area. The result must be between 3 ft. and 7.5 ft. Parts of the pond can be deeper than 7.5 ft., but in no case can any part of the pond be less than 3 ft deep. 64/ If the 85% TSS chart is used a 30' vegetated filter must be provided at the outlet of the pond. If the 90% TSS chart is used, no filter is required. 7. ✓ Use the correct SA/DA TSS chart from the BMP Manual noting that there are different charts for different areas of the State. 8. ✓Required surface area at permanent pool. 9. ,Provided surface area at permanent pool (Based on pond dimensions) 10. Required volume calculation based on 1.5" storm for Phase II projects* and 1" storm for all others projects. *unless the project is Phase 11 and within '/z mile of and draining to SR waters then the volume calculation must be based on difference between the pre and post development conditions for the 1-yr 24-hr storm. 1'hvTable of elevations, areas, incremental volumes and accumulated volumes for overall pond and for forebay, to verify volumes provided. 12. VForebay designed to hold 20% of the permanent pool volume. (Range of 18%-22% OK.) 13V Non -erosive flow for 10 yr. storm in the vegetated filter, if using 85% TSS. 14. ✓The seasonal high water table must be at or below the proposed permanent pool elevation to assure that the necessary volume will be available above the permanent pool. 15Y Rounding numbers off during the calculation process can result in deficiencies. Do not ✓round the numbers until you get to the final result. 16. An additional one foot must be excavated below the bottom elevation of the pond. The 1 foot sediment accumulation depth is not included in the average depth calculation. Wet Detention Pond, cont. C. PLANS- Due to storage space constraints, plan sheets should be kept to a minimum. For small commercial single wet pond projects, the plan set could consist of only 2 or 3 sheets, layout, grading and details. For larger projects, show as much information as possible on as few sheets as possible, without cluttering them up. 1. y/ Development/Project Name 2. v/Engineer name and firm. 3.✓Legend 4. ✓North Arrow 5. ✓Location Map with nearest intersection of two major roads shown. Major road is any 1, 2, or 3 digit NC, US or interstate highway. 6.r/Revision Scale- standard engineering scale, no off-the-wall stuff. 7. Date 8. number and date, if applicable. 9. Original contours, proposed contours, spot elevations, finished floor elevations, pipe nverts, swale inverts, etc. 10. Existing drainage (piping, swales, ditches, ponds, etc.), including off -site. Include a map delineating the offsite drainage areas. 11. Property/Project boundary lines, bearing & distances. 1211� Mean High Water Line or Normal High Water Line, if applicable. n 13The permanent pool elevation must be above the SHWT and above the lowest elevation of adjacent wetlands. Evaluate the need for a liner and/or berm/slurry wall to prevent dewatering the wetland. 14.0 Drainage easement widths, pipe sizes and swale inverts are provided. 15� Wetlands delineated, or a note on the plans that none exist. Get a copy of the wetlands delineation map signed by the Corps of Engineers, or have the applicant include a copy of the unsigned delineation map submitted to the Corps. Wet ponds may not be located in wetlands unless a permit to fill those wetlands has been obtained. 16. �Detailsforthe roads, parking, cul-de-sacs, including sidewalk width, radii, dimensions & slopes. 17.0A, partment / Condo development- Provide a typical building footprint with dimensions and note all concrete and wood deck areas. 18. The drainage area for each wet pond is clearly delineated and numbered to match up to the calculations and supplement. Drainage area delineation is best done as a separate /plan sheet. 19. A pond section detail to include the forebay, a 10 foot wide vegetated shelf, pertinent elevations for the bottom, permanent pool, temporary pool, and SHWT, 3:1 slopes above the permanent pool, and the weir elevation between the main pond and the ✓forebay. 20. The 10 vegetated shelf extends 6" below and 6" above the permanent pool elevation. 21.�An outlet structure detail showing a trash rack with <_6" square openings, the necessary orifice invert elevation (i.e., the permanent pool), orifice size and temporary pool elevation. 22. Dimensions for each line and arc formed by the permanent pool contour. 23��here the 85% TSS chart was used, a 30 ft. vegetated filter strip is required to be shown on the plans & detailed (elevations, inverts, slopes, and flow spreader mechanism). Please note that the filter strip is not a ditch. 24.,A, forebay is provided for each inlet and located so as to prevent short-circuiting. 25. VThe pond must have a minimum 1.5:1 length to width ratio and a minimum 3:1 flow path length. Artificial "baffles" of timber, vinyl, or earth can be used to create a longer flow path. The top elevation of the baffle should be set at the temporary pool elevation or 26YA Vegetation plan is specified for the pond, including slopes. Wetlands species are listed for planting on the 10:1 shelf. Weeping Love Grass is not suitable as a permanent vegetated cover for pond slopes. 27.l�All roof drainage must be directed to the pond. Show the roof drain collection lines on the plan. This is necessary for projects where the buildings back up the property lines where roof drainage may leave the site prior to going through the pond. i , . "t, XJF� APR 1 6 2"b Stormwater & Erosion Control Calculations State Farm Insurance Office US 70 Service Road/Stratford Road Havelock, NC Prepared for: Comer Family, LLC 107 Greenfield Heights Boulevard Havelock, NC 28532 Prepared by: Avolis Engineering, PA PO Box 15564 New Bern, NC 28561 (252)633-0068 FAX (252) 633-6507 April 1, 2008 STO VALUAT'=A eALX-L4UArloA)S STF�1E FA4RM =asurz-A4C4 vFFle_ L45 -+o SE.RVIGE R.oAD/ !sr?ZATro90 RoAV E}Avet,u rrK , /JG TlilS SITE WiLt` G6 jEvEt,oPEQ "IT -I+ A- 5MIQ OFFIC91 C44rCV,. Tr+C FIF-w F-j rr-4ot)AA)r NIU. aE A STAtM FARA OFF16fE. 1-7+-6 SIrE is 1.1Zg3 Acaf�5 l� -r74FRE 15 ,vor &#u j EX15-rl-J61 pEVEWP AENY OF T?+E 517E, 11tE SIrE IS AR r�L Avr-VA6�.4— 6! OLA6V ELr--\A -TIorI 15 qq•S Bh5ED OvJ A4j AsSoAm F— 7 E.(,EVATIo U• T44- 5E.45WAL, H IS O MTER. T4451,E F�LEV✓krloA) IS '47.00. A/J ADTACX&r -pRAIn At -t DIrC1f ?R.o V l o ES A; 6,Oov 9-D R04j44M�l o U -rt.E.T W rn+ /Ary SN V W-r c-uevArlOrt1 of -46.4' A� n4-E• slrE. TIi�R� qR� ND 40+ vIZ CAVAA WETt/4A]UPs oa '"+E 15tr . -T1�ER E 1 asf ojbr AiOJ I " 5LU E L We " StKEAM 5 Of, 'R I PAR IAA BUCF--i�-R.S On) TI+E SITF_, 5(AoA/N(tR.y OF PROPo5C12 5w r-U170n) AkeA;S_ • To-rAi- s ! Te "rA = 4A i 1� Z. s>- • FRDwT ArZr-AS = a FRO✓JT S�DEWAI,K = 1,3se 5F SLI 5F: 1/ � ik)✓ • 'RE.4(L Sid�E1.J/�(.,K= �33 SF Wk D2iv,�-wAIS/FARY-AA16 = o �44 SF V/ !Dry, sM �E2V►;'o� 5 Ate- A 1zIzZia 5f DtLI>JEWA�� _ CpIJ,JECT10�5= 111 l2 5F 30, 6 13 5P' r 1- lza ss E D /BR A = (41A l qz 5 F + I;I I Z s1�, - 3 0 , (,13 5G 12 Tam- 636P /fie+ = Uu1L-r— u polJ /--R.0- 19,(0g 1 51` 30, 4913 `JF = (,0. a °% 4.q1 m?— 5F + (�I 125F ?90POC U51 ain A Wf5t pc, M 51 SMM -m M aC r T)+E 9rRrE. C%Tj 04r52 R1=LZUI?.F- M C-^)rs. WtT- -gF-aulp,F- cAr5 (Tkj, 7/2-Iu4 y�pKiuWAtE2 NIa�vKAL) 25 °I o N lv,04g o RF_,M 0 VAL, 30 1 51'DE SLOPE AP/OVE -cH<LFr NaLp � WGN VAW rAU- 4 lRAt,) -Pow,,, 0jF_FL 2-S -PA�5 3 Fr, M"imvm AfvE?- !Ae FOOL, bCfTH FaRE" I �W1RE-D (Z6O/, DF POND VOLU/KE) 6 Fr MINlmvm FIZZEgOARD ovcR ,MAX, FeND 57-AL,E — �0 Fr WIPE vIE&%ETPrTE-p 3tWGF MIM. i3F�5W LEn)GTN TO uJ,9n4 RAria M i r 1, FLO W FA'1'►4 12,AT10 = 3.1 U5E TABLF- W-3 OF Srna./ tditrEi' MAfJRAfL -Ta SIDE I �J, TJc51A1V FOR qa% T55 REDuc-i'oa 51N6E T415 51 �£ O F ?D a P W I LL 6 L50 5AiI5�F,`� I uChW C i 01= I-}/t'�'E LOCK N+ TE Jl5u,5E $A5W YEAY. PG00,.-rl") ZQVlKE7MFiJTS GE nJEgA". -PI,t,r- -D Av5I-( 6 9EPT14 REQulftEMEaTS, mu5r iW)4 ANT'° 'F?}E -PS6(Ad Dr- r+E- on» 's CALCQC rE- _8UE1zRGE PaND VEPfN zGA)bTLWG r-H-C P>EREFAa�q� TI+E MAIN POn)D i=vbvA -n-E FDRE3AM. BASED 00 AN AUERNSE }?0�)9 !?EFn4 OF +', 5Afj,4= 5,1j6D4 'Prr.5-�U vKtA)ARj Pea D 51 W-= S 3& o/o k 50, 3o4 SF ?�O-0 lAf-3�35toA1S ', (`Y,)(3-c) Zpq� 5� ', = 30 ' 3x= qo' /CE ti how �4-1-5 porJv WILL uicEcN RAWS -M BE Somme 51zLF- LARGER OVL ICJ T)+e AA ►PPZ E- -TV ,SFITls F y T41E �VERfiG-C 'pE•PT1+ RE611.tIREM�ieJTS. CAL-cuLAT-C- n+E Av,-F:PA6,s vr-pTw I� ACG49DA1�C€ Nino eoD u FJ Awh,qE?r* Sti SA C& W--; � (5A) — �-�VOL (V) \ Y i a30TThm VUI.UPA S A W-Ac-E 1 ft C4'F-rCk. H`ic- 3U'* C\0' ?P AWE,JT {Pool, f%irNE.J51D.� FIRS]. eXCAVA'fE T14e PD OV Tb — S0 Fr 'Ve fm4 1,Jn-3-E &MLAK 'P1MeA)51DYJs AAA 'L VOL- Curves vot'. 4z, o 2' *- 6 Z' 124 51 (D F+3 ® F4 3 4-5.0 (,` w G6' 3O\(0 doU ® FTI # 44,D 101 * -+o' +Do 548 .54col 45• o 14' '� �' 1,o3�r $(0 8 14110 46.0 ��' 8' I;�o 4- \zZo z•&310 46.5 Zo'+- 8n' \1000 i45I 335� q--•o 2-00a' I(400 Ig — S.4�ND9fS 5HELr, No Cl7-E-QIT DI%E—TD CLEA/J Ov1T ElE'V, AV - -Vv-?V = 41,13.E t-T = Z, ss of 2o' 90 AW, -Dcfn+ EOD5 LAP aeW� WAI 3EUtJ �,o F+ ��J1TIpnt.t} Pc55ur�E�� 5v 'PoaT� M":57 -gE Ex)&AWrOD, DER-WTLM ANei3FETL liyoATmi). 105' f?EFMA/)6 )T jOOL, —Z2'A495,f ';>Ib . GnNYu(ArL UI-MEA)SIOn1S &W & V_nc, Cua1M Vol 41.0 3' * }3' 21°, Fie 0 F+�, a7 F}3 4Z.o 71* 7-4' sag 3il cr °"r0 F43 43.0 1(' A B\' 0`11 9/15 �7/5 94. 0 15' 85' IZ7s 1005 I;+q 0 +3%0 I�` M, 1403 3291 q 0.0 Z3' q3' Z 131 1,9 IS Z5' q5' 2-31S 1,129 (,�324 ZS' �`,95' Z375 Av(, PEPrN = 7s11 Ave, p; r-rH- Zs��s' 5l%ocllef TH-.e-- flap tgVER4c,E -De?Tgl �Du "t , aEe:yJ FO CLP.,—�-D LArM l:-P) ) SA IDA W 1rr+ 7K CortCu�t;) 6O.'l °% Butq i�>f�Pu�4rLCVocf; � =,srr'R'?ozA-M 81r 3.0 4 3.5' Dc FrH ON °1U'/p 5mIS24-rA5C.E sAb� �� �0.�►�1 = �.�sd/a + o.oq(�.�s°�-lo,6s° IX , / Sv"Af,.E AefA= ((9• 90 S70,3046� = 34 /1 5F > , t-OWACs—'- A"A fcOUIoEp 'T-fv?z , 3,& qS SF V 7 3,4I1 5� // x v o W A o A ►+CRP 4 s ibc T)w- ,wig, oRagq pr�� Cw2R AVEA VoL. CLWM. VOL. +Z' 3S rD pJ 43' \ 4 s' 323 Zsq 433 4(P•5' 597 2 (0-+ �t43 4 •v' 929� - 3 1 )CN1D OtJLI r 4z.' J � 0 0 44' Is I}I 1Z40 4s' 1235 \,n-is Z345 4V isOT i411 3�s6 4&,5, l--�3 $4.3 45IV) +To' r-4 C/o F0ZF- AI vouvm6 = Ft3 = 2 i• Z°io 1S� �-Y F}3 Z1.2°% N CAtCuLATC \" 5-rnV-tA 'RUOOFF \JOL ME U5fc -p+E "51MFLr- /h�t�►��„ i�v = O,Os -t ()•°\ * TA �v = IRVIJo�-F C/o SF- F�C16A)r �A = r�FRVIo is FRAcrite) V = 0, 05 +- O, LA 0,60= 0• S"\$ V= 3 b 30 V R- * Rv tk A V= Vnl,uv^e OF RuaoFF -Cb �3E C�orYT oLLeD (Tf+ �D= 'DESlW s-cV'LrA —�LAlNFALL -pE.p-n.} (s�) y WA�9,S14 .Al A-��A VDL,= '*5D ix 0.59b 4� j, 155/'« = ZEO- - Ft3 v DETTRmitJE ?orvV sit3�iE�sronAC�� ��G�+r�a�ysNiP -rbTA-t- VOL, oa '4pfAff) 'Lvat-w+3) A30vE Pam. Pi 0' 4-4. 0 Ft, ® W o F+3 O-s 44.9 S,14S 2121Z Zz 12- I. 0' 48. o 5, &&4 2-1+0'a 4 AZ'O 2,0' 4q. 0 ('opg6 (o,l �>0 Ol t o 0 3-o' 50.E �,800 :T,Z4(6 1S1340 CALcu(.ATF— I" STDP-K F Ini 'ForiP Vo�NrrE s�vEv 6£ r� 4-7•0' 4 4f,5` C6fj7-b RS= ZzIZG Vut-. To le?f- lE5y%vCD = ZSO-� - 4z (Z. = Z�jS F13 ec;evAnolo Rim 3ETwF-Ca 2aI5- F13 0.5 2qo$ F7t3 50--c ogirle-E rdK �A'1 �(L4u7noc��J AvtPAGE t = Z E O -4 &0 ✓l"l3/HR�((oa6eC/w1rN) = 0,015 e4 3's n ©RiFicr- cau(4T►o) Q = CD A , k -D vsc A -ROE. (a -Fs) C = Gaof VjfxC4A'RGE �= ORiF1eE cRos�-S�eT,or�.4c. I (-`RAUITj (3a.� F+/5Z) h�= -pR-t v1,JA 0EA-T.;' C Ff) SOLVE FOR oR'FICr- A",4 _ 104) A f-rA ( F+Z) O. 0 I S FOIS 3 co, can SOLvE Hof. PiAMErF-R 7 A = _:/? 4 D= 4 _ -SL o•OD�2 Ff� (5 lac NES jlr.-}ES F7)E, I/ !� 5-rAtJDA J.D V)M i, 9 ) 7- SIZE ►2 �CWo r- 'MIS Gfla TAX, D�SIG,r� TR-E- Po-),)D Uu-r(,,F-T- STAUCTd()UTv A-rMAlaA-r,5 �E�Qu I u-,r— ,�n EtJ-r6 T}W- 1 0-�j E.tFL- 04- H-Daf- �ro2*1 FEP, C I"r�.l OF �VELuCr— -R rvI9,EJA5A)T-S. CA-cu(.A-rE Iv_C 12C-Vo fM6--a-r -(�u�0FT:7 Rq-7'E5 usl�J� VA-r15odf}L MF_-,T}'017 SI,jCE WET alk5t.) suppGEME�✓T /5 1 �D Tav)A72-D5 T 115 /fM£TNOP, Log 'CHIs PA-rA Tb �R-E- �EV�(.D �.•� E PVT Ca � 171 rj O r�� C= O l� DFr�SE s01Ll FcAr (Rr--F i+RM E�tti;hrfl� = O. I(n la I NIA Z-��L, Z4— than- Sroe2r�1 �FF Sf_CPPM �BGE 8.03L i0-�21Z4-ft-Du4- 57-Prz.*1 �EsrG� Fb 1z- 2-19- s-raa-m t1s, / -�I2 Nd QV2_ 0-7—A= (0,17) (0./(o l��/�/��1,/SS�c)= 0.051 �'f3/5 PuST T%EVe-LD pMgiuT CDr1T%ITfUrJS C - 10.1-+V o,4sA iFbbO T?4-RAu6i+ Pvxuv + o.qs o.41s + �•b �z3,��• (, 15S AC� 12 c9v = crf} _ �D, �6)� d. /lo i�/��ex/• /ssflc) _ o, I zz W) OF1o= CZ�= �0•(o(pxo.Zs /f/2��/,/SS/�c>= O.I�I �t3%s USE. LtJVOF(�61A1 TD Rr,�r€ S-r7r_� e 115 'n}{L0U6'% W T}if-S P6,-3 u511)G 04-S S ,6 W1E7-N0l7 5C-5 /✓►ET40-0 Lywer♦�us2G ' /f�peoc o�rL G ou? C- C f\j = CoV ilpE rz 1qI3TR10/KT1oA) 3,-4 1,-1 H '4,J6gL . Z4-RgfO-E--pex)s TME1,J-r GIP; 3.7z cry 7, 0 IAJC14 9AI Jf:f4 .. icy M61-)+0D �o14-rlh7(,j T)4Por 6H Pa�D l- VJ(L Z4- V}L fbST 1�EVFL ?M9t'jT cN= 88 Z• Z3 CF5 10 `�'-, 24- J+H vicz POST- 17EV9UpME.)7- (gyp � - Q••ql� C,�S to NpW lzbtATE Tl3g OIUE— jF—AP— 4 , ? -ffau2 PiF.5/6M 6T�R✓*15 THV-oUAH —r� DE->S,-J-riaJ po D /v-�p Ou-r(iE STevCrw�. MUST GF_-7 tPoST Ti�VEC a /�tM�NT Fo p 17a��n1 TU �/LE—SJEVEC.u�r-�E.�r C���1T(orJS• K, C T-i-E—:� Fou.00l• c, 0"rt -r ov,irice A-r fccv. o 2, 4' uo-1,06: a. q--r 5(gv = 9 (v Ff. 1. o (o c.F s Z- I. Z4 CFS — 0 K- Yi�AK 5TAGS = 1-414 P Qv,o — 3,}l JERK- srA�E = 48•Z�{- �� ?IFA lC rct (,) -,E pUGrt v,ti1 �EQ U r E M iJI'S Ake �t,3 U'-17ER 'tom M15ZT F9,E lj5OAR.D i OI�TL�� ST?,uc -Fit CC SKETCH 4 "4 Co,�C f<� � L} " o' — gg.24 fr y' w-�R- s7o 2,4 4" Pvc, 46�0 14g X �Co,�ctu of-Irlc, 45-o — -Vbp eooliaG = 44 }� --(I' x (0' F (AA)VA;io,3 — 1 12 CALCu641-)� (EQu f 2ED hrt&44o ra Cp,= 4 /Ir 4' * (48.8 1,61F4 3, 8 8 # Cori c2E,-� 1L L 144,5)(4'y-a, J�/4s'O1FY I�(,�EQ- F"Tn-riorj — or-- CAt.CYc r6. r2Eur2Z!P WAC—C. F607797-1 F�5' �•S�z(��(�45 I�irf�= Its Al- 19,�- 64,S R2lf:,i3 59 2Wx I' C4n1c6TE rwPeg- P)P4, 7W4&,<# 7Y25 C, ry o - M VEGocx- Hydrograph Summary Report Page 1 rHyd. type (origin) HydrographW6732)0 to k n) Volume (cuft) Return period (Y rs) Inflow hyd(s) Maximum elevation (ft) Maximum storage (cuft) Hydrograph description SCS Runoff2 5,424 1 — 1-YR, 24-HOUR PRE- SCS Runoff.2 15,888 10 — — 10-YR, 24-HOUR PRE 3 SCS Runoff 2.23 6 732 9,637 1 — — 1-YR, POST DEV 4 SCS Runoff 4.90 6 732 21,986 10 — -- 10-YR, POST DEV 5 Reservoir 1.06 6 750 9,438 1 3 47.87 4,232 1-YR POST DEV 6 Reservoir 3.71 6 738 21,787 10 4 48.24 6,396 10-YR POST DEV Proj. file: STATEFARM.GPW OF file: STATEFARW ADF Run date: 03-30-2008 p-f;---9E"�cLafCA&Ur r3j) bt�S 1 - SCS Runoff -1 Yr - Qp = 1.24 cfs Fl. 5 1. C1 0.5 0.0 0 5 10 15 20 25 Time (hrs) / Hyd. 1 2 - SCS Runoff -10 Yr - Qp = 3.72 cfs 4 3 CJ 2 JL 0 0 5 10 15 20 25 Time (hrs) / Hyd. 2 Y�C�� C— Tc>ti:p 3 - SCS Runoff -1 Yr - Qp = 2.23 cfs 2.5 2. 1.5 CY 1.0 0.5 0.0 0 5 10 15 20 25 Time (hrs) / Hyd. 3 D�' Teycupx6d+ av,)➢1-rtbr35 4 - SCS Runoff -10 Yr - Qp = 4.90 cfs 0 5 10 15 20 25 Time (hrs) / Hyd. 4 65r VFnELbefOE-JT 7-Reseirvoir -1 Yr - Qp = 1.06 cfs 2.5 2. u) 1.5 a 1. 0.5 0.0 0 20 40 60 80 Time (hrs) / Hyd. 3 / Hyd. 5 a �A�P 6 - Reservoir -10 Yr - Qp = 3.71 cfs 5 4 3 U 2 1 0 0 10 20 30 40 Time (hrs) / Hyd. 4 / Hyd. 6 Hydrograph Report Page 1 English Hyd. No. 1 1-YR, 24-HOUR PRE-DEV Hydrograph type = SCS Runoff Peak discharge = 1.24 cfs Storm frequency = 1 yrs - Time interval = 6 min Drainage area = 1.15 ac Curve number = 74 Basin Slope = 0.5 % Hydraulic length = 240 ft Tc method = USER Time of conc. (Tc) = 10 min Total precip. = 3.70 in Distribution = Type III Storm duration = 24 hrs Shape factor = 484 Total Volume = 5,424 cuN Hydrograph Discharge Table Time -- Outflow (min cfs) 690 0.07 780 0.22 870 0.12 960 0.08 ... End Hydrograph Report Page 1 English Hyd. No. 2 10-YR, 24-HOUR PRE-DEV Hydrograph type = SCS Runoff Peak discharge = 3.72 cfs Storm frequency = 10 yrs Time interval = 6 min Drainage area = 1.15 ac Curve number = 74 Basin Slope = 0.5 % Hydraulic length = 240 ft Tc method = USER Time of cone. (Tc) = 10 min Total precip. = 7.00 in Distribution = Type III Storm duration = 24 hrs Shape factor = 484 Total Volume = 15,888 cult Hydrograph Discharge Table Time -- Outflow (min cfs) 654 0.19 744 2.36 834 0.35 924 0.23 End Hydrograph Report Page, English Hyd. No. 3 1-YR, POST DEV Hydrograph type = SCS Runoff Peak discharge = 2.23 cfs Storm frequency = 1 yrs ' Time interval = 6 min Drainage area = 1.15 ac Curve number = 88 Basin Slope = 0.5 % Hydraulic length = 300 ft Tc method = LAG Time of conc. (Tc) = 13 min Total precip. = 3.70 in Distribution = Type III Storm duration = 24 hrs Shape factor = 484 Total Volume = 9,637 cult Hydrograph Discharge Table Time -- Outflow (min cfs) 636 0.11 726 2.03 816 0.22 906 0.14 End Hydrograph Report Page English Hyd. No. 4 10-YR, POST DEV Hydrograph type = SCS Runoff Peak discharge = 4.90 cfs Storm frequency = 10 yrs Time interval = 6 min Drainage area = 1.15 ac Curve number = 88 Basin Slope = 0.5 % Hydraulic length = 300 ft Tc method = USER Time of conc. (Tc) = 10 min Total precip. = 7.00 in Distribution = Type III Storm duration = 24 hrs Shape factor = 484 Total Volume = 21,986 cuff Hydrograph Discharge Table Time -- Outflow (min cfs) 606 0.25 696 0.74 786 0.59 876 0.32 .End Hydrograph Report Page 1 Hyd. No. 5 1-YR POST DEV Hydrograph type = Reservoir Storm frequency = 1 yrs Inflow hyd. No. = 3 Max. Elevation = 47.87 ft Slomge Indicetion method used, Peak discharge Time interval Reservoir name Max. Storage English = 1.06 cfs = 6 min = STATEFARM = 4,232 cuft Total Volume = 9,438 cuft Hydrograph Discharge Table Time Inflow Elevation Clv A Clv B Clv C Clv D Wr A Wr B Wr C Wr D Outflow (min) cfs ft cfs cfs cfs cfs cfs cfs cfs cfs cfs 810 0.23 47.72 3.79 0.03 -- -- 0.31 - - - - 0.33 900 0.14 47.67 3.48 0.03 - - 0.14 -- - - 0.17 990 0.09 47.65 3.32 0.03 -- - 0.08 - - - 0.11 1080 0.06 47.63 3.20 0.03 - - 0.05 - - - 0.08 1170 0.05 47.62 3.12 0.02 - - 0.03 - - - 0.06 End • I Reservoir Report, Page 1 Reservoir No. 1 - STATEFARM Pond Data Pond storage is based on known contour areas Stage I Storage Table Stage Elevation Contour area Incr. Storage Total storage ft ft sqft cuft cult 0.00 47.00 3,675 0 0 0.50 47.50 5,175 2,213 2,213 1.00 48.00 5,664 2,710 4,922 2.00 49.00 6,696 6,180 11,102 3.00 50.00 7,800 7,248 18,350 English Culvert 1 Orifice Structures Weir Structures [A] [B] [C] [D] [A] [B] [C] [D] Rise in = 18.0 1.1 0.0 0.0 Crest Len ft = 2.4 0.0 0.0 0.0 Span in = 18.0 1.1 0.0 0.0 Crest El. ft = 47.60 0.00 0.00 0.00 No. Barrels = 1 1 0 0 Weir Coeff. = 3.00 0.00 0.00 0.00 Invert El. ft = 46.80 47.00 0.00 0.00 Eqn. Exp. = 1.50 0.00 0.00 0.00 Length ft = 40.0 0.1 0.0 0.0 Multi -Stage = Yes No No No Slope % = 1.00 0.10 0.00 0.00 N-Value = .011 .013 .000 .000 Orif. Coeff. = 0.60 0.60 0.00 0.00 Multi -Stage = - Yes No No Tailwater Elevation = 0.00 ft Note: All otAlms have been analyzed uMe, inlet and outlet control. Stage I Storage 1 Discharge Table Stage Storage Elevation Clv A ft cuft ft cfs' 0.00 0 47.00 0.24 0.50 2,213 47.50 2.39 1.00 4,922 48.00 5.65 2.00 11,102 49.00 10.24 3.00 18,350 50.00 13.32 CIv B Clv C Clv D Wr A Wr B Wr C Wr D Discharge cfs cfs cfs cfs cfs cfs cfs cfs 0.00 - - 0.00 - - - 0.00 0.02 - - 0.00 - - - 0.02 0.03 - - 1.82 - - - 1.85 0.00 - - 11.93 - -- -- 10.24 0.00 - --- 26.77 - - - 13.32 Hydrograph Report Page 1 Hyd. No. 6 10-YR POST DEV Hydrograph type = Reservoir Storm frequency = 10 yrs Inflow hyd. No. = 4 Max. Elevation = 48.24 ft Storage Indicetion method used Peak discharge Time interval Reservoir name Max. Storage English = 3.71 cfs = 6 min = STATEFARM = 6,396 cuft Total Volume= 21,787 cuft Hydrograph Discharge Table I Time Inflow Elevation Clv A Clv B Clv C Clv D Wr A Wr B Wr C Wr D Outflow (min) cfs ft cfs cfs cfs cfs cfs cfs cfs cfs cfs 720 3.10 47.95 5.36 0.03 -- — 1.47 — -- -- 1.50 810 0.48 47.79 4.24 0.03 — — 0.61 — — — 0.63 900 0.29 47.72 3.79 0.03 — — 0.30 — -- — 0.33 990 0.18 47.68 3.58 0.03 — — 0.18 — — — 0.21 End Reservoir Report Page 1 English Reservoir No. 1 - STATEFARM Pond Data Pond storage is based on known contour areas Stage / Storage Table Stage Elevation Contour area Incr. Storage Total storage ft ft sqft cuft cuft 0.00 47.00 3,675 0 0 0.50 47.50 5,175 2,213 2,213 1.00 48.00 5,664 2,710 4,922 2.00 49.00 6,696 6,180 11,102 3.00 50.00 7,800 7,248 18,350 Culvert / Orifice Structures Weir Structures [A] [B] [C] [D] [A] [B] [C] [D] Rise in = 18.0 1.1 0.0 0.0 Crest Len ft = 2.4 0.0 0.0 0.0 Span in = 18.0 1.1 0.0 0.0 Crest El. ft = 47.60 0.00 0.00 0.00 No. Barrels = 1 1 0 0 Weir Coeff. = 3.00 0.00 0.00 0.00 Invert El. ft = 46.80 47.00 0.00 0.00 Eqn. Exp. = 1.50 0.00 0.00 0.00 Length ft = 40.0 0.1 0.0 0.0 Multi -Stage = Yes No No No Slope % = 1.00 0.10 0.00 0.00 N-Value = .011 .013 .000 .000 Orif. Coeff. = 0.60 0.60 0.00 0.00 Multi -Stage = -- Yes No No Tailwater Elevation = 0.00 ft Note. All outlaws have been analyzed under inlet and order control. Stage I Storage I Discharge Table Stage Storage Elevation Clv A Clv B Clv C Clv D Wr A Wr B Wr C Wr D Discharge ft cuft ft cfs cfs cfs cfs cfs cfs cfs cfs cfs 0.00 0 47.00 0.24 0.00 - - 0.00 - - - 0.00 0.50 2,213 47.50 2.39 0.02 - - 0.00 - - - 0.02 1.00 4,922 48.00 5.65 0.03 - - 1.82 - - - 1.85 2.00 11,102 49.00 10.24 0.00 --- - 11.93 -- - - 10.24 3.00 18,350 50.00 13.32 0.00 - - 26.77 - - - 13.32 NCDENR Stormwater BMP Manual Chanter Revised 07-02-07 Table 10-3 Surface Area to Drainage Area Ratio for Permanent Pool Sizing to Achieve 90 Percent TSS Pollutant Removal Efficiency in the Coastal Region, Adapted from Driscoll,1986 Percent Permanent Pool Average Depth (ft) Impervious Cover 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5' 10% 1.3 1.0 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 20% 2.4 2.0 1.8 1.7 1.5 1.4 1.2 1.0 0.9 0.6 30% 3.5 3.0 2.7 2.5 2.2 1.9 1.6 1.3 1.1 0.8 40% 4.5 4.0 3.5 3.1 2.8 2.5 2.1 1.8 1.4 1.1 50% 5.6 5.0 4.3 3.9 3.5 3.1 2.7 2.3 1.9 1.5 607 7.0 6.0 5.3 4.8 4.3 3.9 3.4 2.9 2.4 1.9 70% 8.1 7.0 6.0 5.5 5.0 4.5 3.9 3.4 2.9 2.3 80% 9.4 8.0 7.0 6.4 5.7 5.2 4.6 4.0 3.4 2.8 90% 10.7 9.0 7.9 7.2 6.5 5.9 5.2 4.6 3.9 3.3 100% 12 10.0 8.8 8.1 7.3 6.6 5.8 5.1 4.3 3.6 The engineering design of a wet detention basin must include a 10-foot-wide (minimum) vegetated shelf around the full perimeter of the basin. The inside edge of the shelf shall be no deeper than 6" below the permanent pool level, and the outside edge shall be 6" above the permanent pool level. For a 10' wide shelf, the resulting slope is 10:1. With half the required shelf below the water (maximum depth of 6 inches), and half the required shelf above the water, the vegetated shelf will provide a location for a diverse population of emergent;wetland vegetation that enhances biological pollutant removal, provides a habitat for wildlife, protects the shoreline from erosion, and improves sediment trap efficiency. A 10' wide shelf also provides a safety feature prior to the deeper permanent pool. Short-circuiting of the stormwater must be prevented. The most direct way of minimizing short-circuiting is to maximize the length of the flow path between the inlet and the outlet: basins with long and narrow shapes can maximize the length of the flow path. Long and narrow but irregularly shaped wet detention basins may appear more natural and therefore may have increased aesthetic value. If local site conditions prohibit a relatively long, narrow facility, baffles may be placed in the wet detention basin to lengthen the stormwater flow path as much as possible. Baffles must extend to the temporary pool elevation or higher. A minimum length -to -width ratio of 1.5:1 is required, but a flow path of at least 3:1 is recommended. Basin shape should minimize dead storage areas, and where possible the width should expand as it approaches the outlet. Although larger wet detention basins typically remove more pollutants, a threshold size seems to exist above which further improvement of water quality by sedimentation is negligible. The water treatment volume within a wet detention basin is calculated as the total volume beneath the,permanent pool water level, and above the sediment storage volume, including any such volume within the forebay. Wet Detention Basin 10-8 July 2007 Erosion Control Calculations State Farm Insurance Office US 70 Service Road/Stratford Road Havelock, NC Prepared for: Comer Family, LLC 107 Greenfield Heights Boulevard Havelock, NC 28532 Prepared by: Avolis Engineering, PA PO Box 15564 New Bern, NC 28561 (252) 633-0068 FAX (252) 633-6507 April 1, 2008 E�51o�J ASePIMEdTA-rhd C%/,rlwL CfALCWA-rlod5 4TATIE lr� S,J5 u A-A7JG6 O FF lGE RnADl5TA4rF�Av Po4v ifAuELoCK- �C �ESI�iJ OuT-LC-rj �r v p15Cj4AiLt—C—f f,Jra Iro.JD DeAI/JA&E Are- . q-,::n lz,2zl�s� + �35�d k nazi + �tiou + lwo Zs��uS 5F = O•Soi Ac— C = ©.RS , r= (o•-+o t�IF (1u yCZ-j la—AAIJ 5rroRM) G?p = Cry _ (n, qs�� �• lA-)l j+rL� o,sa AC) -9E5I6,n1 Rip RAp o r&rr P!'oT-zFcr1od 0.06VcL 56cPpm FLJI� Go�D�r�u uS 11-K6 NbT OtiJ TcQM / p�t2�a R 77/ L 14r.) yid S'I ,T��F1iJ��F S� F�G�Ir,JI r�ra o, 2A 41 615E / �f3E5rD I /1%E jNoDS FcsrR $ u FTC�IA Z'� To �-iJI}cr� � SLI FwE , Cep =,JCzH = 0.- 4 GAS \1:we'`tl = D- 84 DEPrw = D, 42 r'f — 4P46 4/ r 12 56 114P- yE5►GN Ft? me F;uTscno,) F-b R. oaaD arst-ttnwxC QP►o - 3 •7+ C'S (FRuwt 5 rp�e M ti12 Gu,,grraws) r1i� iz-E�ro Ube sRrhE RIP RAC ouTc,Er r�er��� des Ili rJ Nitrogen Calculations State Farm Insurance Office 'US 70 Service Road/Stratford Road Havelock, NC Prepared for: Comer Family, LLC 107 Greenfield Heights Boulevard Havelock, NC 28532 Prepared by: Avolis Engineering, PA PO Box 15564 New Bern, NC 28561 (252)633-0068 FAX (252) 633-6507 April 1, 2008 i oFF� CAI-CU A -re N 1-rp oGrE� T 9F_ATwtc yr FoR. C lr� or j+AtV ock 7bTAL. 51TE- A, A = SF 5,TE Alt-E-A AV�a9 6 j W- CL,)A-j Cov,)A)rc n okJS - 1,11Z 5r Tbrww A175uSrED sjrE rl�R = So,3o4 sl' IssA,-) TH-E ?9-oTEC.T' 15 VEQui9-ED TD 13E P=2 irrED Fb'R Co ^PcnA CE w ITN Tl+,6 co�}s�wt 5raRr^w tZ RF.Gucftrian�s. s i4ra>}cHEt7 cA�c��A,�u�as. TH-E Q¢u cr (,01tL 3E t./61/46 A WE-r e�ErE.vr�anl pbrJD SI:L�XD FO)P- rjo°/ 'i55• 1?I-E WEr Wlcc REr�uvE Z, �% cj= TN-E N1rRUG��. A PoRTnor1 OF r" -W, RtAR Fk9.y AAA Af'EA /SILL 4z-5o ?i2F_-' IN ✓l AgA55 Su//jLE ''R102. 'N l7�sGGH iP+�E I.JTo rj1£ JET For1D, -M/5 7�2og;grl"45.Nr /5 /uFE0E-D jCET T-W n)I-F9OCeO Evfogr VfJT6 Tb /�cC,EP rAC3c E (,EVE`s. ,5 rvtMARi U F .TM e EP V+ o uS 4WA5 e 1'RONT �ARKI+xj I172IUE �plS = �21ZZf, Sr FRDrJ"r SI91,wAt. - = I13555 5F REPYV-- !SIDEWALK = �33 sF REAR VRdUEt eilA t / P/rKKIA36 = 10331 Sr Ib 1+09-FA = 14�- 5r- -1�rW1, T/LnPe2-VjOU5 a p-s4-_ 09A1�56l✓9 ,AAA= 1%61� SF (o-4Sa Ac) TN E�Vb2r= (0•403 /kc)(21.2 WA,) }- (0.452Ac)(1.z Ib/Ac) `TN ] �PPg:r = I S. 4-5 \� i rrlPc OS TN E':XfoZ-r 9ATt= iS.gs l+ = 13 38 MAc l • Iss /3-c- ?6r,yu -ri -Ve-p�C'no-') = Zo °% =::�' T7J F1yoRr � SuGNrc rDa N IGN W1 �6-JD Odd w1-n+ � i'gA56 5�� To RaDU� T� �ycQ6iLT Fu /z�I+E(Z (A55- CIA" Cur I'j T)FE '('V"F-P� OF TNT FAKKI&)K GbT- -T t' C-C-r r 1: l lZuaoi:�"F W ro T?+l� 5U1 )� MAX VEcoC i o St l S 1-p>: SAES 51A)61,r t-4�?Jr- - /So F+/ MAX, 5upc = S°% /V�NST pA55 i f U -Ae STDR/�? l�i9FEG 'I.��� � a /.o �+ s��Ft �1-r lu �J F�e.> n� SNwr�6c.Ev. 4�•v F+> SWALE c.r AIT-r+ =, 4l 14, AV.t�-A %�kZAvJlr)l- LEdGrN OF 5WAc- E R,EQu i 2Ev Te, F.EM0 uE Zo61 7-d -T�+E 41 Ff SW�tI.E l.�i�TN CAS lkCGor�push� zo °/ !ZEMOuA-f. _ a,3 ,specs 6r516- Z r„NFS TN Flo w I,i ro s L A+.E = (o. loco Q ( ZI. Z 1 b /A� = Z. 4� `FtJ ArF-r 5 &d = I�0 So�� I, qi �� = 1, SS 4 (SEC- V-o5ie,0 CA.cuc.4-no1J5 Foil Sa 44,6 A�7—`-$-) 3f 4 _._ SM�ERVlo�tS � Ivor D k�nli J� Tv Sr.Jq[E = 30� (a 15 — 5034- D Sg :f ,etc. n T✓�) Fc- OW a -ro om _ `0, S8 �)��1, z > a (0,42A)(1.2 + 14, s7 r� TN ArrEQ- rLoO Tt-IMP4 Pe.a�= �D. �S,i� l4 S�`"y•v�= I (�.qa t —ry Fgar RATE= 1,15S�c, O fQc e o EXFwr r T4i6 HA-s 8),:!'EvJ Ti2g� p o WoJ 7a —rK LF-VF.L Wl+ P-� 6r CAr1 SE (3o r�-r �&YLd� -r✓v Bk1 Down A-(noKaT = (5.45- 3_6 115-S-A)( 577.Sb> 5.--�4&, (Dz 5W 1,70g0LI FINANCIAL RESPONSIBILITY/OWNERSHIP FORM APR 18 2008 SEDIMENTATION POLLUTION CONTROL ACT No person may initiate any larid-disturbing activity on one or more acres as covered by the AAct#befo'reyths 0 form and an acceptable erosion and sedimentation control plan have been completed and approved by the Land Quality Section, N.C. Department of Environment and Natural Resources. (Please type or print and, if the question is not applicable or the e-mail and/or fax information unavailable, place N/A in the blank.) Part A. 1. Project Name State Farm Insurance Office 1 2. Location of land -disturbing activity: County Craven City or Township Havelock Highway/Street U.S. 70 Service Road Latitude N 34°54.178' Longitude W 760 55.880' 3. Approximate date land -disturbing activity will commence: June 15, 2008 4. Purpose of development (residential, commercial, industrial, institutional, etc.): Commercial 5. Total acreage disturbed or�uncovered (including off -site borrow and waste areas): 1.2 Acres 6. Amount of fee enclosed: $ 130.00 The application fee of $65.00 per acre (rounded up to the next acre) is assessed without a ceiling amount (Example: a 9-acre application fee is $585). 7. Has an erosion and sediment control plan been filed? Yes X No Enclosed X 8. Person to contact should erosion and sediment control issues arise during land -disturbing activity: i Name Joseph C. Avolis, P'.E. E-mail Address avoliseng(g�lpmonline. net Telephone 252-633-0068 Cell# 252-671-9333 Fax # 252-633-6507 9. Landowner(s) of Record (attach accompanied page to list additional owners): Comer Family, LLC Name 107 Greenfield Heights Boulevard Current Mailing Address Havelock, NC 28532 City State Zip 252-444-1700 Telephone Current Street Address City 252-447-3596 Fax Number Zip 10, Deed Book No. 2698 Page No. 94 Provide a copy of the most current deed. Part B. Person(s) or firm(s) who are financially responsible for the land -disturbing activity Provi comprehensive list of all responsible parties on an attached sheet): V E D Comer Family, LLC E Name E-mail Address 107 Greenfield Heights Boulevard Same APR t k 2008 Current Mailing Address Current Street Address — LAND QUALITY SECTION Havelock. NC 28532 ING1ON O°GIn off.! GED City State Zip City St ip i Telephone 252-444-1700 Fax Number 252-447-3596 2. (a) If the Financially Responsible Party is not a resident of North Carolina, give name and street address of the designated North Carolina Agent: Name E-mail Address Current Mailing Address Current Street Address City State Zip City State Fax Number (b) If the Financially Responsible Party is a Partnership or other person engaging in business under an assumed name, attach a copy of the Certificate of Assumed Name. If the Financially Responsible Party is a Corporation, give name and street address of the Registered Agent: Name of Registered Agent Current Mailing Address City State Zip E-mail Address Current Street Address Telephone Fax Num State Zip The above information is true,and correct to the best of my knowledge and belief and was provided by me under oath (This form must be signed by the Financially Responsible Person if an individual or his attorney -in -fact, or if not an individual, by an officer, director, partner, or registered agent with the authority to execute instruments for the Financially Responsible Person). I agree to provide corrected information should there be any change in the information provided herein. n A... L­/R A___-.__ a Notary Public of the County of State of North Carolina, hereby certify that appeared personally before me this day and being duly sworn acknowledged that the above form was executed by him. Witness my hand and notarial seal, this LL day of -f ;' 20 (' %A'y tSIM4f6/* Notary NMRY PUBLIC My commission expires_,