Loading...
HomeMy WebLinkAboutSW6100601_Plansheets_20100625CU-M-B RLAND COUNTY, NORTH CARO INA DESIGN DOCUMENTS JUN 2010 FOR: 1 V LLLLO CK LLC DEVELOPER: FULLBLOCK,LLC 321 NORTH FRONT STREET /� T TI-� STREET WILMINGTON, NC 28401 3 / 1 NORTH F1 �-(O I \ I 1 S 1 Fl F-1 E-1 1 ATTN: WILLIAM FULLER JR. (910) 763.0380 L� FRONT l �I lJ 1W ENGINEER (CIVIL) DENR—FRO WILMINGTON, NC 28401 PARAMOUNTE ENGINEERING, INC. 5911 OLEANDER DRIVE, SUITE 201 JUN 2 8 2010 WILMINGTON, NORTH CAROLINA28403 (910) 7 6 3 _ 0 3 Q 0 ATTN: ROBERT BALLAND, P.E. (910) 791-6707 D WQ SHEET INDEX SHEET NUMBER SHEET TITLE SITE 3 ` - - C-0.0 COVER SHEET C-1.0 NOTES <P 301 (S Za� C-2.0 SITE PLAN 5i R 4 jog �J C-3.0 GRADING & DRAINAGE PLAN / C-3.OA DRAINAGE AREA MAP m C-4.0 UTILITY PLAN C-5.0 - C-5.4 DETAILS km Toly NOTICE REQUIRED ALL EXISTING UNDERGROUND UTILITIES SHALL BE PHYSICALLY LOCATED PRIOR TO THE BEGINNING OF ANY baba us e11vd1 Ct-';a / CONSTRUCTION IN THE VICINITY OF SAID UTILITIES. �SRp7�• I ey CONTRACTORS SHALL NOTIFY OPERATORS WHO MAINTAIN UNDERGROUND UTILITY LINES IN THE AREA OF (; ICup PROPOSED EXCAVATION AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN TEN WORKING DAYS PRIOR °nstrhe rill � m Caro ar is Qt• 1 I requued sto r� 'he rnw .;n r � h ar erliblIna TO COMMENCEMENT OF EXCAVATION OR DEMOLITION. ��pe 1 rules require that he 3, m d signer a a � storrrnwatel OloO , �H ,)!,h�therme CONTACT CAROLINA ONE CALL AT _6f�51&110 1-800-632 4949 `Ssyen M O C cY_%,al. U ^1C uroision of water C1uai ty Sheet # iUwe CONTACT THESE UTILITIES o � �• •••, °tee CUMBERLAND COUNTY PLANNING PUBLIC WORKS COMMISSION (WATER, SEWER, & ELECTRIC) AM: PAM SPEICHER ATTN: MR. JOHN P. ALLEN, PE Q1� l ���`j 1 �j' a PREPARED BY: PH: 91W8.7605 PH: 910.2234734 - ...... PIEDMONT NATURAL GAS BELL SOUTH Ay LOCATION MAP ': �:C Q pA�AMauNTE SCALE: 1 "=4W NOFTrH 0 • $ �i 'z PH: 910-799-7185 PH: 1A006324949 o• 4 S.�L .fir. E N G I N E E R 1 N G, EMERGENCY DIAL 911 TIME WARNER CABLE _ _ . 36235 N' PH: 910-763463a 5911 Oleander Drive, Suite 201 'c, t{I�.t-- GIN . -`- POLICE - FIRE - RESCUE Opti�Ry Wilmington, North Carolina 28403 ....,,,.<n (910) 791-6707 (0) (910) 791-6760 (F) NC License #: C-2846 PROJECT # 10137.PE FINAL DESIGN - NOT RELEASED FOR CONSTRUCTION i _ I .i T- r. PERMANENT SEEDING SCHEDULE - MIXTURE 5CP Seeding Mixture SPECIES RATE (LB/ACRE) CENTIPEDE GRASS 10.20 Seeding Dates MARCH-JUNE Soil Amendments APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 300 LB/ACRE 10-10-10 FERTILIZER Mulch DO NOT MULCH. Maintenance FERTILIZE VERY SPARINGLY-20 LB/ACRE NITROGEN IN SPRING WITH NO PHOSPHORUS. CENTIPEDE GRASS CANNOT TOLERATE HIGH PH OR EXCESS FERTILIZER. TEMPORARY SEEDING -LATE WINTER/EARLY SPRING Seeding Mixture WINTER AND EARLY SPRING SPECIES RATE (LB/ACRE) Rye (GRAIN) 120 ANNUAL LESPEDEZA (KOBE IN PIEDMONT AND COASTAL PLAIN, KOREAN IN MOUNTAINS) 50 OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE. SUMMER SPECIES RATE (LB/ACRE) GERMAN MILLET 40 FALL SPECIES RATE (LB/ACRE) RYE (GRAIN) 120 Seeding dates COASTAL PLAIN - DECA-APR. 15 - LATE WINTER AND EARLY SPRING - APRIL 15 - AUG. 15 - SUMMER AUG. 15 - DEC. 30 - FALL Soil amendments FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LBIACRE 10,10-10 FERTILIZER Mulch APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. Maintenance REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REPERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. 0 EROSION CONTROL AND SEQUENCE OF CONSTRUCTION NOTES: NOTE: THESE EROSION CONTROL AND SEQUENCE OF CONSTRUCTION NOTES ARE INTENDED FOR EACH'PHASE" OF CONSTRUCTION. THE ORDER AND STEPS TAKEN MUST BE IMPLEMENTED AS EACH PART OF THE PROJECT IS DEVELOPED; WHETHER AS A WHOLE OR IN PHASES. ANY EROSION CONTROL DEVICES/MEASURES MUST REMAIN IN PLACE UNTIL THE ENTIRE BASIN DESIGNED TO HANDLE SEDIMENTATION AND EROSION IS STABILIZED AND ALL IMPROVEMENTS WITHIN THE BASIN ARE COMPLETE. 1. ESTABLISH THE LIMITS OF DISTURBANCE, CONSTRUCT TEMPORARY GRAVEL CONSTRUCTION ENTRANCE($), AND TEMPORARY SILT FENCE. 2. CLEAR AND REMOVE FROM SITE ALL TREES (ONLY ONES TO BE REMOVED), ROOTS, ROOT MAT, ETC. FROM THE AREA WITHIN THE DESIGNATED CLEARING LIMITS. 3. INSTALL REMAINING EROSION CONTROL MEASURES AS SHOWN ON THE PLANS WITHIN THE AREA DISTURBED. 4. PLANT GRASS OVER ALL GRADED AREAS WITHIN 15 DAYS OF CEASE OF ANY GRADING ACTIVITY. 5. IMMEDIATELY UPON THE INSTALLATION OF ANY STORM DRAINAGE CATCH BASIN; DROP INLET, ETC., THE CONTRACTOR SHALL INSTALL INLET PROTECTION TO STOP ANY SEDIMENT FROM ENTERING THE DRAINAGE SYSTEM. 6. IMMEDIATELY UPON THE INSTALLATION OF ANY STORM DRAINAGE SYSTEM, THE CONTRACTOR SHALL INSTALL OUTLET PROTECTION AS SHOWN ON THE PLANS AND DETAILS. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING AND RESTORING TO PRE-CONSTRUTION CONDITIONS ANY AREAS OUTSIDE THE PROJECT LIMITS THAT MAY INADVERTENTLY BE DAMAGED DUE TO THE FAILURE OF THE EROSION CONTROL MEASURES. 8. DURING GRADING AND AFTER GRADING HAS BEEN COMPLETED, THE CONTRACTOR SHALL CONTINUE TO MAINTAIN PERMANENT AND TEMPORARY EROSION CONTROL MEASURES UNTIL FINAL INSPECTION AND APPROVAL BY NCDENR. 9. UPON RECEIVING FINAL INSPECTION AND APPROVAL BY NCDENR THE CONTRACTOR CAN REMOVE TEMPORARY EROSION CONTROL MEASURES. 10. THE CONTRACTOR SHALL CONTINUE TO WATER, FERTILIZE, MOW AND MAINTAIN SPRIGGED, SODDED, AND PLANTED AREAS UNTIL ALL CONSTRUCTION IS COMPLETE. GENERAL EROSION AND SEDIMENT CONTROL NOTES:. 1. UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONSTRUCTED AND MAINTAINED IN ACCORDANCE WITH THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL HANDBOOK. (NO SEPARATE PAYMENT). 2. THE CONTRACTOR SHALL NOTIFY PLAN APPROVING AUTHORITY ONE WEEK PRIOR TO THE PRECONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO FINAL INSPECTION. 3. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO CLEARING AND/OR LAND DISTURBANCE. 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN AND PERMIT SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. 5. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO OFF -SITE BORROW OR WASTE AREAS, STAGING OR STORAGE AREAS), THE CONTRACTOR SHALL PREPARE AND SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND TO NCDENR FOR APPROVAL. CONTRACTOR SHALL PAY ALL FEES REQUIRED AND SHALL INSTALL NECESSARY MEASURES AT NO SEPARATE PAYMENT. THE CONTRACTOR SHALL PROVIDE THE OWNER AND THE ENGINEER A COPY OF THE AMENDED PERMIT. 6. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY EITHER THE REVIEWING AGENCY OR THE ENGINEER. (NO SEPARATE PAYMENT). 7. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. 8. ALL AREAS DISTURBED BY CONSTRUCTION UNLESS OTHERWISE IMPROVED SHALL BE SODDED OR SEEDED AS INDICATED AND STABILIZED. 9. DURING DEWATERING OPERATIONS, WATER SHALL BE PUMPED INTO AN APPROVED FILTERING DEVICE PRIOR TO DISCHARGE TO RECEIVING OUTLET. 10, THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF -PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. 11. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED BY CONTRACTOR ONCE STABILIZATION OR A SUFFICIENT GROUND COVER HAS BEEN ESTABLISHED OR AS DIRECTED BY THE ENGINEER (NO SEPARATE PAYMENT). NCDENRS FINAL APPROVAL IS REQUIRED. 12. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE SHALL BE REQUIRED AT ALLCONSTRUCTION STAGING AREA ENTRANCES AND ALL CONSTRUCTION ACCESS LOCATIONS INTO NON -PAVED AREA. (NO SEPARATE PAYMENT). 13, WHEN CROSSING CREEK OR DRAINAGE -WAY, THE DIVISION OF WATER QUALITY SHALL BE CONTACTED PRIOR TO DISTURBING A CREEK. THE CONTRACTOR SHALL INSTALL RIP -RAP WITH FABRIC DISTURBED BANKS AND CHANNEL AND RESTORE SLOPES TO ORIGINAL CONTOURS, BUT NOT STEEPER THAN 2:1 MAXIMUM. DISTURBED CREEK AREA SHALL BE STABILIZED IMMEDIATELY. MAINTENANCE PLAN 1. ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY TO MAINTAIN ALL PRACTICES AS DESIGNED. 2. ALL CONSTRUCTION ENTRANCES WILL BE PERIODICALLY TOP DRESSED WITH AN ADDITIONAL 2 INCHES OF #4 STONE TO MAINTAIN PROPER DEPTH. ANY SEDIMENT THAT IS TRACKED INTO THE STREET WILL BE IMMEDIATELY REMOVED. 3. SEDIMENT WILL BE REMOVED BEHIND THE SEDIMENT FENCE WHEN IT BECOMES 0.5 FEET DEEP AT THE FENCE. THE SEDIMENT FENCE WILL BE BE REPAIRED AS NECESSARY TO MAINTAIN A BARRIER. SILT FENCE STAKES WILL BE SPACED 6 FEET APART UNLESS A WIRE BACKING IS USED WITH 8 FOOT STAKE SPACING. 4. ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED ACCORDING TO SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A VIGOROUS, DENSE VEGETATIVE COVER. 5. INLET PROTECTION - INSPECT ROCK PIPE INLET PROTECTION AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (} INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING. 5. SEDIMENT BASIN - REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN IT ACCUMULATES TO WITHIN ONE HALF OF THE DESIGN DEPTH. PLACE SEDIMENT IN AN AREA WITH SEDIMENT CONTROLS. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, PIPING, AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE RISER AND POOL AREA. 8. SKIMMER - INSPECT SKIMMER AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL TO MAKE SURE THAT THE INTAKE MECHANISM, ORIFICE, OR DISCHARGE PIPE IS. NOT CLOGGED WITH TRASH OR SEDIMENT. IF THE BASIN IS DRY, MAKE SURE THAT ANY VEGETATION GROWING ON THE BOTTOM IS NOT HOLDING THE SKIMMER DOWN. TAKE SPECIAL PRECAUTION IN WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE. COORDINATION NOTES: 1. THE CONTRACTOR IS REQUIRED TO OBTAIN ANY/ALL PERMITS REQUIRED FOR CONSTRUCTION OF THESE PLANS. 2. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH PERMITS ISSUED AND WITH THE CITY OF FAYETTEVILLE, CUMBERLAND COUNTY, PWC, AND THE STATE OF NORTH CAROLINA. 3. THE CONTRACTOR IS TO ESTABLISH AND CHECK ALL HORIZONTAL AND VERTICAL CONTROLS TO BE USED WITH THE PROJECT. IN ADDITION, THE CONTRACTOR IS TO COMPUTE THE LAYOUT OF THE ENTIRE SITE PLAN IN ADVANCE OF BEGINNING ANY WORK ASSOCIATED WITH THE SUBJECT PLANS. CONTRACTOR SHALL EMPLOY A PROFESSIONAL SURVEYOR TO PERFORM SITE IMPROVEMENT STAKEOUT(S). 4. ANYTIME WORK IS PERFORMED OFF -SITE OR WITHIN AN EXISTING EASEMENT, THE CONTRACTOR IS TO NOTIFY THE HOLDER OF SAID EASEMENT AS TO THE NATURE OF PROPOSED WORK, AND TO FOLLOW ANY GUIDELINES OR STANDARDS WHICH ARE ASSOCIATED WITH OR REFERENCED IN THE RECORDED EASEMENT. 5. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS BY OTHERS FOR ALL BUILIDNG DIMENSIONS AND DETAILS. GENERAL NOTES: 1. EXISTING CONDITIONS AND TOPOGRAPHIC SURVEY COMPLETED BY PARAMOUNTE ENGINEERING, INC. THE SURVEY SHALL BE FIELD VERIFIED BY CONTRACTOR AND ANY DISCREPANCIES REPORTED TO THE OWNER, OWNERS REPRESENTATIVE AND/OR ENGINEER IMMEDIATELY. 2. REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS. THE EXACT LOCATION OF ALL EXISTING UTILITIES IS NOT KNOWN IN ALL CASES. THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF DITCHING OPERATIONS BY OBSERVATIONS, ELECTRONIC DEVICES, HAND DIGGING AND BY PERSONAL CONTACT WITH THE UTILITY COMPANIES. IN ORDER TO LOCATE EXISTING UTILITIES IN ADVANCE OF TRENCHING OPERATIONS SO AS TO ELIMINATE OR MINIMIZE DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS RESULTING FROM ANY DAMAGE TO THE EXISTING UTILITY LINES INCLUDING LOSS OF UTILITY REVENUES. CONTRACTOR SHALL ARRANGE FOR TEMPORARY SUPPORT OF EXISTING UTILITIES, SUCH AS POLES, CONDUITS, FIBER OPTIC CABLES, TELEPHONE CABLES, WATER LINES, ETC. 3. CONTRACTOR SHALL COMPLY WITH THE LATEST REVISIONS AND INTERPRETATIONS OF THE DEPARTMENT OF LABOR SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION PROMULGATED UNDER THE OCCUPATIONAL SAFETY AND HEALTH ACT. 4. CONTRACTOR SHALL PLAN AND CONSTRUCT WORK SO AS TO CAUSE MINIMUM INCONVENIENCE TO THE OWNER AND THE PUBLIC. THE CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN AT ALL TIMES DURING THE PROGRESS OR TEMPORARY SUSPENSION OF WORK, SUITABLE BARRIERS, FENCES, SIGNS OR OTHER ADEQUATE PROTECTION, INCLUDING FLAGMEN AND WATCHMEN AS NECESSARY TO INSURE THE SAFETY OF THE PUBLIC AS WELL AS THOSE ENGAGED IN THE CONSTRUCTION WORK. CONSTRUCTION SIGNING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF "CONSTRUCTION AND MAINTENANCE OPERATIONS SUPPLEMENT TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" BY THE DOT. 5. ALL MATERIAL CLEARED OR DEMOLISHED BY THE CONTRACTOR IN ORDER TO CONSTRUCT THE WORK SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE PROPERLY DISPOSED OF OFF -SITE. 6. ALL WORK BY THE CONTRACTOR SHALL BE WARRANTEED BY THE CONTRACTOR FOR A PERIOD OF ONE YEAR AFTER THE OWNER ACCEPTS THE WORK. 7. CONTRACTOR SHALL CALL THE NORTH CAROLINA ONE -CALL CENTER AT 1 (800) 632-4949 AN ALLOW THE CENTER TO LOCATE EXISTING UTILITIES BEFORE DIGGING. SITE NOTES: 1. ANY DISCREPANCY IN THIS PLAN AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE OWNER PRIOR TO START OF CONSTRUCTION. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL SETBACKS, EASEMENTS AND DIMENSIONS SHOWN HEREON BEFORE BEGINNING CONSTRUCTION. 2. CONTRACTOR SHALL MAINTAIN THE SITE IN A MANNER SO THAT WORKMEN AND PUBLIC SHALL BE PROTECTED FROM INJURY, AND ADJOINING PROPERTY PROTECTED FROM DAMAGE. 3. ACCESS TO UTILITIES, FIRE HYDRANTS, STREET LIGHTING, ETC., SHALL REMAIN UNDISTURBED, UNLESS COORDINATED WITH THE RESPECTIVE UTILITY, 4. DO NOT SCALE THIS DRAWING AS IT IS A REPRODUCTION AND SUBJECT TO DISTORTION. 5. THE GENERAL CONTRACTOR SHALL REMOVE ALL DEBRIS FROM THE SITE UPON COMPLETION OF THE PROJECT AND AT LEAST ONCE A WEEK DURING CONSTRUCTION. 6. THE GENERAL CONTRACTOR SHALL KEEP THE AREA OUTSIDE THE "CONSTRUCTION LIMITS" BROOM CLEAN AT ALL TIMES. 7. ALL UTILITIES TO SERVICE PROPOSED STRUCTURE SHALL BE UNDERGROUND ON SITE. 8. ALL STREET SURFACES, DRIVEWAYS, CULVERTS, CURB AND GUTTERS, ROADSIDE DRAINAGE DITCHES AND OTHER STRUCTURES THAT ARE DISTURBED OR DAMAGED IN ANY MANNER AS A RESULT OF CONSTRUCTION SHALL BE REPLACED OR REPAIRED IN ACCORDANCE WITH THE SPECIFICATIONS. 9. CONTRACTOR SHALL MAINTAIN AN "AS -BUILT" SET OF DRAWINGS TO RECORD THE EXACT LOCATION OF ALL PIPING PRIOR TO CONCEALMENT. DRAWINGS SHALL BE GIVEN TO THE OWNER UPON COMPLETION OF THE PROJECT WITH A COPY OF THE TRANSMITTAL LETTER TO THE ENGINEER. 10. IF DEPARTURES FROM THE SPECIFICATIONS OR DRAWINGS ARE DEEMED NECESSARY BY THE CONTRACTOR, DETAILS OF SUCH DEPARTURES AND REASONS THEREOF SHALL BE GIVEN TO THE OWNER FOR REVIEW, NO DEPARTURES FROM THE CONTRACT DOCUMENT SHALL BE MADE WITHOUT THE PERMISSION OF THE OWNER. 11. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES. THE LOCATION OF ALL EXISTING UTILITIES ARE NOT NECESSARILY SHOWN ON PLANS AND WHERE SHOWN ARE ONLY APPROXIMATE. THE CONTRACTOR SHALL ON HIS INITIATIVE AND AT NO EXTRA COST HAVE LOCATED ALL UNDERGROUND LINES AND STRUCTURES AS NECESSARY. NO CLAIMS FOR DAMAGES OR EXTRA COMPENSATION SHALL ACCRUE TO THE CONTRACTOR FROM THE PRESENCE OF SUCH PIPE OTHER OBSTRUCTIONS OR FROM DELAY DUE TO REMOVAL OR REARRANGEMENT OF THE SAME. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO UNDERGROUND STRUCTURES. CONTACT NORTH CAROLINA ONE CALL" TOLL FREE 1-800-632-4949 AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING ALL NONSUBSCRIBING UTILITIES. 12. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL INSPECTIONS, CERTIFICATIONS, EQUIPMENT, ETC., THAT MAY BE REQUIRED. 13. THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THE CONSTRUCTION MEANS AND METHODSASSOCIATED WITH THE PROJECT AS SET FORTH IN THESE PLANS. 14. ALL LOT STRIPING AND DIRECTIONAL ARROWS TO BE YELLOW REFLECTIVE MARKINGS AND SHALL C04FORM TO NCDOT. 15. ALL PARKNG LOT DIMENSIONS ARE FROM FACE OF CURB. 16. LANDSCAFE PLANTINGS AT ENTRANCE/ EXITS WILL BE INSTALLED AND MAINTAINED SO AS NOT TO INTERFERE WITH SIGHT DISTANCE NEEDS OF DRIVERS IN THE PARKING AREA AND AT ENTRA4CE/EXIT LOCATIONS PER LOCAL STANDARDS. 17. SEEDING 10 BE INSTALLED TO LOCAL REQUIREMENTS & STANDARD PRACTICES. 18. ALL DIMENSIONS AND RADII ARE TO OUTSIDE FACE OF BUILDING OR TO FACE OF CURB UNLESS OTHERWISE NOTED. "PP o ' L."rnw , F;iT j)t3 Lt!-,2nts ConstCUacr, c c ",= dc ,ments is rIOU ed to w n I; chna rules e� 1131 .he 'I), nspec f..m 7eclgner con _ "forrrity with the has aril �a. s '1 _ r a e with the '!OF nW e5. ' A e1PjzT�/* yy*,�,� ng_s: .)f ,N'ter Quality Sheet tt_�-�. --Revision 0ate_4/Ww/z? Z 0 N w D: W O N W V U -1 v-�pZw �w P",0 0 UxF-+00 p E-I C7 °° aP4zo 0 w0�-Im LL �za� w `~ O w CT) C1% WU�o� �O ON Z N r- 7 T�1 0 to p� z yo rc La�^ W �zo �I Z -a. O (D �Z Lr)�O P-4 W U I� W �I ��z--++ °0z F_� U pQ0 I-+ U NWH Pi O z 1-4Uz mm Mmm Z 0 a Q Q 55 z F o0LL 0 H 55LU zo " U, U qg'0 W a UJ W 0zw ei z :k Ii1�L�3U D_ UdaK 00000L) SEAL 6235 J C-1 *0 PEI JOB#: 10137.PE SITE 3 1 ate• @^ 301 __j 6 LOCATION MAP SCALE:1"=400' NORTH SITE INFORMATION PROJECT NAME: LOT 2 @ AIRPORT COMMERCE PARK PROPOSED USE: OFFICENVAREHOUSE BUILDING TAX PARCEL NUMBER: 0435-14-1782 SITE ADDRESS: 115 AIRPORT ROAD LOT 2, AIRPORT COMMERCE PARK CURRENT ZONING: M(P) (PLANNED INDUSTRIAL DISTRICT) TOTAL SITE AREA: 2.14 ACRES OWNER INFORMATION: FULLBLOCK, LLC WILLIAM FULLER, JR. 321 N. FRONT STREET WILMINGTON, NC 28401 (910) 763-0380 DIMENSION REQUIREMENTS FRONT SETBACK 100, SIDE SETBACK 50' REAR SETBACK 50' MAXIMUM HEIGHT 36 BUILDING INFORMATION 1-STORY OFFICEIWAREHOUSE BUILDING - 12,000 SF TOTAL FOOTPRINT TOTAL PARKING (OFFICE/WAREHOUSE) REQUIRED: (OFFICE) 1 SPACE PER 300 SF NET FLOOR AREA REQUIRED: (WAREHOUSE) 1 SPACE PER COMPANY VEHICLE, TWO SPACES PER THREE WAREHOUSE EMPLOYEES REQUIRED: (OFFICE) 12 SPACES (3,699 SF NET) REQUIRED: (WAREHOUSE) 16 SPACES (4 COMPANY VEHICLES, 18 EMPLOYEES) TOTAL REQUIRED: 28 SPACES TOTAL PROVIDED: 28 SPACES HANDICAP PARKING REQUIRED: 2 SPACES HANDICAP PARKING PROVIDED: 2 SPACES SIGNAGE DESIGN CRITERIA: SECTION 1305 & 1306, CUMBERLAND COUNTY ZONING ORDINANCE EXISTING UTILITIES SANITARY SEWER: 8" SEWER (BRIDGEWOOD DRIVE) WATER: 8" MAIN (BRIDGEWOOD DRIVE) STORM SEWER: PUBLIC (BRIDGEWOOD DRIVE) GAS: N/A ELECTRIC: OVERHEAD (AIRPORT RD. - SOUTH SIDE) UNDERGROUND (BRIDGEWOOD RD.) TELEPHONE: UNDERGROUND (BRIDGEWOOD RD.) FIRE HYDRANT: 2-PUBLIC (1-BRIDGEWOOD DRIVE, 1-AIRPORT RD.) PROPOSED UTILITIES SANITARY SEWER: 4" SCH 40 PVC SEWER SERVICE WATER: 314" WATER SERVICE ALL UTILITIES SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST DETAILS AND TECHNICAL SPECIFICATIONS OF THE FAYETTEVILLE PUBLIC WORKS COMMISSION PWC (PWC). STREETSCAPE AIRPORT ROAD - 257LF / 5OLF = 5.1 REQUIRED PROVIDED ONE LARGE SHADE TREE PER 5OLF: 5 5 (OR) TWO SMALL ORNAMENTAL TREES PER 5OLF: 10 0 BRIDGEWOOD DRIVE - 353LF / 5OLF = 7.1 REQUIRED PROVIDED ONE LARGE SHADE TREE PER 5OLF: 7 7 (OR) TWO SMALL ORNAMENTAL TREES PER 5OLF: 14 0 YARD SPACE AIRPORT ROAD -12OLF BUILDING WIDTH REQUIRED PROVIDED ONE ORNAMENTAL TREE PER 50LF: 2 2 TWO SHRUBS PER 10LF: 24 25 BRIDGEWOOD DRIVE - 100LF BUILDING LENGTH REQUIRED PROVIDED ONE ORNAMENTAL TREE PER 5OLF: 2 2 TWO SHRUBS PER 10LF: 20 21 PARKING AREA LANDSCAPE TOTAL PARKING SPACES = 28 SPACES REQUIRED PROVIDED ONE LARGE SHADE TREE OR TWO SHADE TREES FOR EVERY 20 SPACES: 1 5 Plant list Trees & Shrubs Key Qty Common Name Size & Specs. CM 17 Natchez Crape le 8'-10' HGT. 4' LMED CLEAR MULTI -STEM GA 35 lGlossyAbelia 3 GAL. CONT ND 45 Nandina domestics Harbor dwa 3 GAL. CONT EA 35 Encore azalea 3 GAL. CONT Grasses/Sod Sod Centipede 17,701 s uare feet Contactor shall ensure that at the time of plangrgl sod adequate water shall be provided by means of irrigation and/or hand watering fora period of four months beyond the date of project corn etion and acceptance b the owner or owners representative Mulch Pinestraw 9,254 square feet rox. 185 bales PLANTING NOTES: 1.) THE SIZE OF THE TREES TO BE PLANTED SHALL BE A MINIMUM OF TWO INCH CALIPER FOR LARGE SHADE TREES AND A MINIMUM OF SIX FEET IN HEIGHT FOR SMALL ORNAMENTAL TREES. 2.) REQUIRED PLANT MATERIALS SHALL BE MAINTAINED BY THE PROPERTY OWNER, INCLUDING REPLACING DEAD OR UNHEALTHY TREES AND SHRUBS. 3.) ALL YARD AND PLANTING AREAS SHALL BE MAINTAINED IN A NEAT, ORDERLY, AND PRESENTABLE MANNER AND KEPT FREE OF WEEDS AND DEBRIS. 4.) WHEN RETENTION/DETENTION BASINS ARE REQUIRED BY THE STATE OR LOCAL ORDINANCES FOR STORMWATER, WATERSHED OR OTHER PURPOSES, THE BASINS SHALL BE SECURED WITH A MINIMUM FOUR FOOT HIGH FENCE WITH ALOCKABLE GATE. �C ROGERS & BREECE INC PIN #: 0435-15-3050 DB 4235 PG 164 I FUTURE DUMPSTER IF IT IS DESIRED TO NOT INITIALLY PAD LOCATION PAVE THE LOADING / UNLOADING (SEE DETAIL) AREA, 8 ABC STONE COMPACTED' TO 100% ASTM D698 CAN BE USED IN PLACE OF THE HEAVY DUTY PAVEMENT SECTION - • ' • ■ it - «i ���i oiT. - • ■ i ��£ N R�I,"NOI�,�OIN v, #, •t "N ♦ I o. e. FPr Fxa 7 N �!G 4121.I`I � GIGO-yGGgGI,g, `,GIeI U •'}5V' s 3 `'P�I`NOjGIs r tl OI O �A t�, L .- I1l ■ E \0 O) j <OPROPOSED < i MI`OI,��tI l 5 l r♦ ♦♦ �.�J�Y<� M <��� .�. O� N OI OI • . � „� - • ■ �R� lye .. • - • .. s�::"�•!+N. �gI��NOI ;OIpr4liO� �. �N �•I�O.•�.��i•'�o �: Cis.�Gl`��,v4I j,4i • ' • ■ �,�� cINOiO,�� �G�I`` tr•�QII • •• ►.� e + °• i — — = EXISTING PROPERTY LINE — — = EXISTING EASEMENT = PROPOSED CONCRETE SIDEWALK = PROPOSED BUILDING FOOTPRINT = PROPOSED GRAVEL �T ^! = PROPOSED SOD/GRASS AREA X= EXISTING TREE TO BE REMOVED = FUTURE ASPHALT DRIVE 4 GA 4 GA 4 EA 0— 4 EA Lu 0 m 4 GA 4 GA 3_l ROGERS & BREECE INC PIN #: 0435-14-6951 DB 4235 PG 164 PROPOSED5'CONCRETE SIDEWALK PROPOSED 2'-6" CONCRETE CURB AND GUTTER HEAVY DUTY PAVEMENT �- SECTION SHALL BE USED IN THE LOADING/UNLOADING AREA AND REAR DRIVEWAY GROVE & LIBBIE CONTRACTOR SHALL SAW CUT SERVICE, CO., LLC EXISTING CURB AND GUTTER AND REMOVE +/-74LF AS SHOWN PIN #: 0435-14-5604 DB 6376, PG 723 PROPOSED TRAFFIC ARROW (TYP.) FUTURE ASPHALT DRIVEWAY (LIGHT DUTY PAVEMENT SECTION) PROPOSED5'CONCRETE SIDEWALK PROPOSED 2'-6" CONCRETE CURB AND GUTTER CONTRACTOR SHALL SAW CUT EXISTING CURB AND GUTTER AND REMOVE +/-62LF AS SHOWN L=32.96' R=45.00' CHORD= S50.44'00"W 32.23' PROPOSED TURN DOWN SIDEWALK TO BE IN ACCORDANCE WITH CURRENT ADA ACCESSIBILITY GUIDELINES PROPOSED HANDICAP PARKING MARKINGS AND SIGNAGETO BE IN ACCORDANCE WITH CJRRENT ADA ACCESSIBILITY GUIDELINES (TYP.) DENR-FRCS JUN 2 8 2010 DWQ WINSTEAD RENTALS LIMITED PIN #: 0435-14-4419 DB 5120, PG 677 Asa. 64'. •tl "t b regw p I y t, I.0 - rents is '3 lifl3 r cC/L' e P 9�ec� �u nc 'm e Tyner V V+ n an 1 sto mwa pr � f Maker (�Ualhp GRAPHIC SCALE • 60 90 SCALE:1'=30' EL�TT W 0 a a W U it U W m U Z a o � ° N > w W W c/� N W UZZ� w w �w0(D ~' O _o Ux�oo '4 Z o W O z aZ z�- O_ w )� :3L3-f cM G� W� o� ` _ Z N N (7 � N O Z �a U e p - U� W 4)zo I� W >~ o a Q/) �1 Z O l\ 0 to ON w v W Z O 0 Z �..1 U �-_i O Q P4 U W lP4 �D O cn 1-a U Z oommm Hasa Z O 1= Q = N O la— ° ° o 35 F- Z c9 ��z�o 0 w�o¢N Z O UW W d TINT—`30 �aZL 0 o ooc=i ,,,,• ....... sea,4.v,�� CARO Fessi =n.a SEAL cf) 046235 ST •:yGINe °•.0l'HER C-200 PEI JOBM 10137.PE POND #1 OUTFALL Line ID Length Size Material Sloe Down Rim Uft in % M178.42 AInv.Rim ft ftMH-2 TO FES-1 29 18 RCP CL. 111 0.51 - 184.50 DI-3 TO MH-2 42 15 RCP CL. III 0.50 184.50 182.20 DI-4 TO DI-3 43 15 RCP CL. III 0.50 178.57 182.20 182.20 DI-5TO DW 58 15 RCP CL. III 2.50 178.57 180.30 182.20 185.40 DI-6 TO MH-2 141 15 'HDPE or RCP CL. 111 0.75 179.15 180.21 184.50 183.90 *ALL HOPE PIPE SHALL BEADS N-12 HP STORM PIPE OR APPROVED EQUAL AND SHALL BE INSTALLED TO MANUFACTURER SPECIFICATIONS. NOTES: 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH ALL CUMBERLAND COUNTY STANDARDS AND SPECIFICATIONS. 2. THE CONTRACTOR SHALL PLACE INLET PROTECTION AROUND ALL STORM DRAIN INLETS TO PROTECT THE STORM DRAIN SYSTEM FROM CLOGGING DURING CONSTRUCTION. INLET PROTECTION SHALL REMAIN IN PLACE UNTIL ALL SURFACES ARE STABILIZED. 3. THE LANDSCAPE ISLANDS IN THE FRONT PARKING LOT SHALL BE CONTAINED USING EXTRUDED CURB. THE DRIVEWAY CONNECTIONS SHALL BE STANDARD 2'-6" CONCRETE CURB AND GUTTER AS DETAILED. 4. ALL PROPOSED SPOT ELEVATIONS SHOWN IN THE PARKING LOT ARE AT PROPOSED EDGE OF PAVEMENT ELEVATIONS. 5. ALL ROOF DRAINS SHALL BE DIRECTED TO DISCHARGE TO THE STORM DRAINAGE SYSTEM. 6. ALL HDPE PIPE SHALL BE ADS N-12 HP STORM PIPE OR APPROVED EQUAL AND SHALL BE INSTALLED TO MANUFACTURER SPECIFICATIONS. WET DETENTION / SEDIMENT BASIN NOTES: 1. THE PROPOSED WET DETENTION POND SHALL BE USED DURING CONSTRUCTION AS A SEDIMENT BASIN UNTIL THE SITE IS FULLY STABILIZED. 2. THE CONTRACTOR SHALL CONSTRUCT THE SEDIMENT BASIN TO THE PROPOSED DEPTHS OF THE WET DETENTION POND AS ILLUSTRATED ON THE PLANS AND INSTALL THE PROPOSED OUTLET STRUCTURE. ONCE THE OUTLET STRUCTURE IS IN PLACE, THE CONTRACTOR SHALL IMMEDIATELY INSTALL THE SKIMMER TO THE PERMANENT POOL DRAWDOWN ORIFICE. 3. ONCE THE SITE IS STABILIZED THE CONTRACTOR SHALL REMOVE ALL SEDIMENT FROM THE BASIN AND ESTABLISH THE FINISHED GRADES OF THE PROPOSED WET DETENTION POND, INCLUDING THE VEGETATIVE SHELF. 4. REFER TO THE SEDIMENT BASIN DETAIL FOR THE REQUIRED SEDIMENT REMOVAL ELEVATIONS DURING CONSTRUCTION. � I OUTLET PROTECTION RIP RAP APRON #1 (SEE DETAIL) - 20' UTILITY EASEMENT EMERGENCY SPILLWAY'' (SEE DETAIL) 10' VEGATATIVE SHELF (SEE POND SECTION DETAIL) PROPOSED 6' CHAIN LINK SECURITY FENCE W1 LOCKABLE GATE /1 FOREBAY PROTECTION - (SEE DETAIL) OUTLET PROTECTION - RIP RAP APRON #2 (SEE DETAIL) ROGERS & BREECE INC PIN #: 0435-04-9899 D135115,PG312 1 / INLET PROTECTION - / (TYP-j /1 PG=184.19 O PG=185. i 3=184 - ' \ / FFE=186.25 I - I 1 DI-6 PG=185.42� w II/ { !tom ! �II, Y t TEMPORARY CONSTRUCTION ENTRANCE (TYP.) TP , I [SEE DETAIL] WINSTEAD RENTALS LIMITED PIN #: 005-14-4419 DB 5120, PG 677 PG=184.42-1 PG1!..'50-7 85.60 1 LPG=186.96 f 20/ t/7 i LIMITS OF DISTURBANCE (TYP.) N qtI/ AIRPORT ROAD S.I.2260 I [98,300 SF (2.56 Ac.)] (ROW VARIES) `` JOy S5 SS SS SS ----SS -SS-SS-SS-SS-SS-SS-SS-SS _SS SS SS -SS -SS -SS -SS �j SS�SS # III SS SS I 1�1 W L-w-w-w-w-w-w- ,., w-w�-w-w- w-�--w--w-w-W ---w- w--w- i I DENR--FRO JUN 2 8 2010 DWQ I I I U cry I � I O - O nP9iPa"ktli_-.`d 1 "9iYM 1 F Q �OtSi y sz - regw ed bV .: r ,i rwa roe ear 1hn he yr t<r'i rolma trsyec q , " ern fe igne; r" iam ar confo mity with the SIO -rWsr ar d t.F..e wCn the f 1 1 - � : �71 e , n �Q O_ d,eiv� l0 yy Nu an of Wale, " LEGEND: `" n`9---C' evsion'ate S� � - - 199-- EXISTING CONTOUR 199 PROPOSED CONTOUR O EG=198.90 �� EXISTING SPOT ELEVATION PG=197.90 -----. PROPOSED SPOT ELEVATION PROPOSED DRAINAGE FLOW PATH INLET PROTECTION DI = DROP INLET W MH = MANHOLE GRAPHIC SCALE 0 15 30 60 90 H SCALE: 1`=30' I , Ik \MCP � 1 I ROGERS & BREECE INC PIN #:0435-14-6951 DB 4235 PG 164 GROVE & LIBBIE SERVICE, CO., LLC PIN #:0435-14-5604 DB 6376, PG 723 WINSTEAD RENTALS LIMITED PIN #:0435-14-4419 ^.0, PG 677 1 I I I I DENR—FRCS ' JUN 2 8 2010 DWQ Z C) I UI I z C) — — Q W O7 cPri . 0V i l�[ Igvt I f 4'it. ai a r w, aqui eu c „r "w� n _!ina V J es requlCl-"'he sn s n ener i»[fwith the 0i39s all and Ge� !he `IJ '+ s.c , `ater Cualhy 3,QA _ evtsionL�ate GRAPHIC SCALE o s30so SCALE: 1"=3W z 0 xz w H W 0 U � Z d- N Zw W o w o L W az�� �~ O o o w cn w0 cl) 1;� -"=d, o a� r: 1 c p N Z y ccd 6U w w -sz° W U ! 0o Z a: O � o'S;D�z -� W U � W z O v O Icy U P4 Q (Du oommm maaa z O Q oo i O I- 53zO U U �qg� z w a ww ww ..� 0 ZW�uS wW�3QQCYi O K Z w Q U W K 2 d U(.LLK 0 p(nOOU SEAL ,,.4.�� CAF;O'°..,, SEAL 0 036235 Z • V 2 C-3*OA PEI JOB#: 10137.PE RA 1/8" RA D. • d d - . 1•< d 4" i < n. a' 1/2" JOINT Y118" RADIUS, TYP. SEALER DUMMY GROOVE EXPANSION JOINT CONTRACTION JOINT VARIES (SEE PLAN) 3,000 PSI 1/4" PER FT. CONCRETE SECTION VIEW 6" ASPHALT ° •_ a _f /_ PAVEMENT 112" EXPANSION JOINT- MAX. 50' O.C. & BETWEEN STRUCTURES GROOVED CONTRACTION-� JOINT PLAN VIEW SIDEWALK DETAIL NOT TO SCALE t'LAIV VItVY 50' MIN. 5" DIVERSION TO DIRECT RUNOFF FROM RAY - SECTION VIEW TEMPORARY CONSTRUCTION ENTRANCE NOT TO SCALE TOP OF RISER = 182.00 1" SCH. 40 PVC DRAWDOWN ORIFICE 1.0" STORAGE ELEVATION = 181.41 NORMAL POOL EL. = 180.50 i0 pAr OW --JJ Z I- J N =_jTn -I am> y H L 0 E D Z rn r- 0 M � �=Z m T- O G) K o S 31 0 Gm I..1 v 1 N' Z �oT=O mz =-1 ==DDm =000 A zj lor-R boo,, D aJ'-' I-- z MANHOLE Vn -4 _ 54 ,� FOR MANHOLE COVER 6 FRAME xq IAHS_"C"A°� PLANNNNOPTIONAL SPACED 8 BRICK MAY BE USED C. TO C. TO ADJUST FRAYS 6 COVER TO SURFACE ELEVATIOi MAX. 1'. i 1 ' OUTLET PIPE - o - E OR F Lill. A I SECTION SECTION X-X C-C OR D-D P , 4' ; S SEE B SECTION Y-Y GENERAL NOTES: CHAMFER ALL EXPOSED CORNERS 10. USE CLASS "B" CONCRETE THROUGHOUT. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS TO CONSTRUCT THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF BOX, ADD TO BASE AS SHOWN ON STANDARD NO. 840.00. PRWIDE ALL JUNCTION BOXES OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTERS IN ACCORDANCE WITH STD. NO. 840.66. ADJUST THE STEEL, CONCRETE AND BRICK MASONRY QUANTITIES TO INCLUDE THE ADDITION OF THE MAMIaE (I.E. DIAGONAL BARS SHORTENED AROUND OPENING IN TOP SLAB, ADDITIONAL VARIABLE HEIGHT BRICK MASONRY, OPENING IN TOP SLAB.) MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP ELEVATION IS 12 FEET. #4 BAR e" DOWEL - DIMENSIONS AND QUANTITIES FOR CONCRETE JUNCTION BOXES DIMENSIONS OF BOX AND PIPE REINFORCEMENT I SARS 'A" -TOP SLAB DIMENSIONS CIVIC YARDS IN BOX TOTAL WANTITIES BOX AND SLABS DEDUCTIONS FOR ONE PIPE CU.YDS. PIPE SPAN WIDTH HEIGHT D A B H NO. LENGTH E F TOP SLAB BOTTOM BLAB MU.1 Fi. OF Hf. LBS. REINF W. YDS. YIN. H" C.S. R.C. 12" 2'-0" 2'-0' 2'-3" f2 2'-9^ 3' 0", 3'-0" 0.167 0.167 0.185 22 0.750 0.015 0.024 15" 2'-3" 2'-S" 2'-8^ 12 3'-0" W-3" 3'-3" 0.196 0.196 0.204 24 0.902 0.023_ 0.036 18" 2'-0' 2'-Bn V-9" 14 3'-3" 3'-6" W-60 0.227 0.227 0.222 30 1.065 0.033 0.049 24' 3'-0.. 3'-0. 3'-3" 18 3'-9. 4'-0" 4'-0" 0.296 0.206 0.259 40 1.434 0.059 0.085 30" 3'-6. - W.G. 3'-9" 18 4'-S" V-6" 4'-6" 0.375 0.376 0.286 51 1.860 0.092 0.127 36. 4'-0" 4'-0" 4 -S" 20 4'-9" 5'-0" 8 -0" 0.463 0.463 0.333 64 2.341 0.132 0.178 -8" 4'-8" 4-9' 22 $'-9^ 5'-8" 6'-8" 0.580 0.560 O.S70 77 2.878 0. 180 0.243 48" 5'-4" 5'-4" 5' 3" 26 6'-8" 8'-L. 8'-4" 0.743 0.743 0.407 111 3.623 0.235 0.317 54" 5'-10" W-10 W-9" 28. W-7" 6'-toff 8 -10" 0.865 0,865 0.444 126 4.283 0.297 0.401 60" 6 6'-s" so x-s" 7-B" T-e" 1.042 1.a2 0.4e1 145 5.090 0.367 0,495 MAn T-1" T-1^ 8'-8" 92 7'-10" 8'-1" 8'-1". 1.210 1.210 0:518 169 5.917 0."4 0.589 A SOLID COVER SHOWN PERFORATED. PERFORATED AVAILABLE IF SPECIFIED. STATE USE OF SYSTEM ON COVER (I.E.: SEWER, STORM DRAIN, ELECTRICAL) TOP OF COVER I--*Cd AN BOTTOM OF COVER 1" R. PLAN OF COVER m Z PLAN OF FRAME m CC = -n Z 1'-11%11 1 D � m o _` ZTYPE #1 O G�7j m d' \ / /\ \ ALTERNATE SECTION A -A 1 OF 1 .54 - TYPE #2 C4 6' EL. 180.00 (TOP OF RIP -RAP) FILTER FABRIC 6" THICK CLASS'B' RIP -RAP GALVANIZED BAR GRATING 1" x 1/8" BEARING BARS. FOREBAY PROTECTION DETAIL FASTEN WITH J-CLIPS, ATTACH TO A 1 1/4" x 1 1/4" x 114" NOT TO SCALE GALVANIZED ANGLE FRAME. MORTOR FRAME TO TOP OF OUTLET STRUCTURE Fri � / / OUTLET PIPE (1) 12' RCP CLASS III / INV. UP = 180.50 INV. DOWN = 180.50 / SLOPE = 0.00% J 4'x4' REINFORCED NOTE: CONCRETE BOX 1. FOR MAINTENANCE EFFORTS OR IN CASE OF EMERGENCY, STORMWATER STORED BELOW PERMANENT POOL SHALL BE PUMPED. 2. ALL STORMWATER (INCLUDING ROOF DRAINAGE) MUST BE 6" EXTENDED BASE CONVEYED TO THE STORMWATER BMP. OUTLET STRUCTURE DETAIL NOT TO SCALE I �1 G--444" long" - SECTION B-B MINIMUM WEIGHTS - LBS. FRAME -180 COVER - 120 TOTAL - 300 SPECIFICATION CLASS 30 IRON MEETING ASTM A-48 0 as 3 ac cGO O ¢ co = Z LL ~ta.T¢00 DoHLL LLOW O�cga Z ' CL H In cc LL p LL �mLU ¢Fi�a O J to ¢Za (D cc F F 0 cj 00 V M 1J7O3 Z (� W 0 H } a•C NocV o O y = Z = Z w< U.=.} co I­ 0J�OZj I- " IL 0 LL i O z0 Jim m a oa p W a z I= g U. rn Of) J O J = z Q W Te d S 0 z <M r 11/2" 3 6" o¢ 7° o 1" DEPRESSION 158" 11/2 y{�0/8" ..r azoo� Ho��y 1' 7�S" 1'-7�8" Imo- H F o0Z=z 0 =Am=�Dy��� <��xMm �G Q< cn - N0r ON Z�DZ MQ o 0 or- LLI caZ SECTION G-G -4= H �� L4W 1'-411t F-r PLAN OF FRAME LO CAST IRON m o m PLAN OF GRATING cc "' 0D 0 2'-3%" CAST IRON 0 CD R cr = o T p -vi 1/8" 1/8" 1/ ,r 2 Q OD tl BOD Z In to to to to p w o p c 3' 33/4" 2, < 3 Q n " _ Q 1 SIB 2 p OC com O /8„ LBu j8" LBn z IL p 0 zv 00 � SECTION H-H „ 4 `-2zl� 1, 3�2 -2M 'a = J ~ D = o 1 J S 1 F~H o>� 21/8° -ITT 2/8 �dLU 3'-134 N N 2'-1344" N N W O LD au m cn o co m s 3'-6" 2, 6"cn j O U. SECTION E-E SECTION F-F HEET 1 OF 1 - SHEET R OF 1 840.16 1840.161 ALL OUTLET PIPES SHALL HAVE FLARED END SECTIONS STORM DRAIN PIPE SLOPE = 0% STORM DRAIN PIPE LENGTH RIP -RAP o APRON PLAN TAILWATER FLOW FILTER FABRIC -/ SECTION RIP -RAP SCHEDULE N.C.D.O.T. CLASS B RIPRAP, MINIMUM 18" THICK, TYPICAL UPSTREAM DOWNSTREAM PIPE DIA. (IN.) LENGTH (FT.) WIDTH (FT.) WIDTH (FT.) 1 12 6 3 7 2 18 6 45 45 NOT TO SCALE DENR-FRCS JUN 2 82010 DWO O U SUITABLE PLANTS WET DETENTION POND PLANTING F-� PICKERELWEED (PONTEDERIA CORDATA) CONTRACTOR TO INSTALL ON THE 10:1 DUCK POTATO (SAGGITARIA LATIFOLIA AND SAGGITARIA CARDINALIS) SLOPED SHELF, EQUAL NUMBERS OF EACH SWAMP ROSE (HIBISCUS MOSHEUTOS) OF THE LISTED SUITABLE PLANTS. DURING BLUE FLAG (IRIS VIRGINICA) INSTALLATION, GROUP SIMILAR SPECIES OF CARDINAL FLOWER (LOBELIA CARDINAUS) PLANTS TOGETHER. INSTALL PLANTS 24" O.C. IN ACHECKERBOARD PATTERN. SOD ALL SLOPES ABOVE PERMANENT POOL EL O 10, 10.1 SHELF 6" ABOVE & 6" BELOW ( 1 EL. 180.50 EL. 184.00 _ PERMANENT SP � OPLANTED VEGETTHH SUITABLE �•/ �10 - EL. 182.25 (TOP OF RIP -RAP) -I '- _10 ERMANEN POOL 180.50 W FILTER FABRIC 6" THICK CLASS'S' RIP -RAP I I-' I I- a 3It s 5' POND H I �-_ w EMERGENCY SPILLWAY DETAIL POND SIDE SECTION NOT TO SCALE NOT TO SCALE �-I OVERFLOW STRUCTURE TOP OF DAM EL. = 184.00 (SEE DETAIL) O ------------------------------------------------ 100YR.EL.=182.58--_____ ____ ----------------------------.-- TOP EL. FOREBAY --------------- 50 YR. EL. = 182.44 25YR.EL.=182.28---------------- -------- 182.06 ' ------------ ----------- -------------___tOYR.EL -- - ------ - 1 YR. EL. = 181.42 - ______... - 1.0"RUNOFF STORAGE EL. =181Al ----- F--1 r� PERMANENT POOL EL. (NORMAL WATER SURFACE) 180.50 1 �, FOREBAY ----- a 3 o 1� r, ., n •� a ea „ E r nt, !" MAIN POND rul" eautrc h I <-n 1 'c W . BOTTOM EL. FOREBAY = 177.00 - - 10' VEG SHELF Ins ' ui c.uri. a i Plan an:i Sr r it wigr` 1h1 A POND BOTTOM EL.=175.50 _tow t;r u sa FOREBAY IS DIVIDED FROM THE ' 1' OF POND DEPTH IS FOR SEDIMENT ACCUMILATION 10:1 SLOPE TYP. AROUND POND r s'W by ✓eater t,u3iRy MAIN POND BY EARTHEN BERM FOREBAY AND STORAGE POND SECTION PER POLICY �t '_-_�.��- _-- e it'r. �ttrS /e - NOT TO SCALE - z NTH�T OU z O N LU o! wl � 00 N U z Zw w O F- °zQ x 0 F- a z a z O Q W0 MO ?o- li p h N z ai O^Lj - 1-I � oN � H W s -(u F-i z O OIJ� z cz n ��o � W � W U W z °C)z 1-4 O P-4 U W N H Q �Uz ogmmm mZQ�¢ o� o Q oz i 00 O LL la- 8 z F- �gz0 0 ' NO O z WSow Ix zw � zz'w �a03w 0_ c°iaLL� p o0a0LL) SEAL ...... .... .. ... ... ..:.... �N CAR "'°•,,, O(i2y= OQL -Fessi' _•: % N - =n;¢ S AL r CO_ 0 2315 - SjOrr C-5.1 PEI JOB#: 10137.PE r r r r r r