Loading...
HomeMy WebLinkAboutSW8160216_Approved Plans_20160310COORDINATION NOTES 1. THE CONTRACTOR IS REQUIRED TO OBTAIN ANYIALL PERMITS REQUIRED FOR CONSTRUCTION OF THESE PLANS. 2. ALL WORK IS TO BE IN ACCORDANCE WITH NEW HANOVER COUNTY, AND THE STATE OF NORTH CAROLINA. 3. THE CONTRACTOR IS TO ESTABLISH AND CHECK ALL HORIZONTAL AND VERTICAL CONTROLS TO BE USED WITH THE PROJECT. IN ADDITION, THE CONTRACTOR IS TO COMPUTE THE LAYOUT OF THE ENTIRE SITE PLAN IN ADVANCE OF BEGINNING ANY WORK ASSOCIATED WITH THE SUBJECT PLANS. CONTRACTOR SHALL EMPLOY A PROFESSIONAL SURVEYOR TO PERFORM SITE IMPROVEMENT STAKEOUT(S). 4. ANYTIME WORK IS PERFORMED OFF -SITE OR WITHIN AN EXISTING EASEMENT, THE CONTRACTOR IS TO NOTIFY THE HOLDER OF SAID EASEMENT AS TO THE NATURE OF PROPOSED WORK, AND TO FOLLOW ANY GUIDELINES OR STANDARDS WHICH RE ASSOCIATED WITH OR REFERENCED IN THE RECORDED EASEMENT. GENERAL NOTES 1, EXISTING CONDITIONS WERE TAKEN FROM A SURVEY COMPLETED BY C.I. GLOVER COMPANY, PC, THE SURVEY SHALL BE FIELD VERIFIED BY CONTRACTOR AND ANY DISCREPANCIES REPORTED TO THE OWNER, OWNERS REPRESENTATIVE, AND/OR ENGINEER IMMEDIATELY. 2. REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS. THE EXACT LOCATION OF ALL EXISTING UTILITIES IS NOT KNOWN IN ALL CASES, THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF DITCHING OPERATIONS BY OBSERVATION, ELECTRONIC DEVICES, HAND DIGGING, AND BY PERSONAL CONTACT WITH THE UTILITY COMPANIES, IN ORDER TO LOCATE EXISTING UTILITIES IN ADVANCE OF TRENCHING OPERATIONS SO AS TO ELIMINATE OR MINIMIZE DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS RESULTING FROM ANY DAMAGE TO THE EXISTING UTILITY LINES INCLUDING LOSS OF UTILITY REVENUES. CONTRACTOR SHALL ARRANGE FOR TEMPORARY SUPPORT OF EXISTING UTILITIES, SUCH AS POLES, CONDUITS, FIBER OPTIC CABLES, TELEPHONE CABLES, WATER LINES, ETC.., 3. CONTRACTOR SHALL COMPLY WITH THE LATEST REVISIONS AND INTERPRETATIONS OF THE DEPARTMENT OF LABOR SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION PROMULGATED UNDER THE OCCUPATIONAL SAFETY AND HEALTH ACT. 4. CONTRACTOR SHALL PLAN AND CONSTRUCT WORK SO AS TO CAUSE MINIMUM INCONVENIENCE TO THE OWNER AND THE PUBLIC. THE CONTRACTOR SHALL PROVIDE, ERECT, AND MAINTAIN AT ALL TIMES DURING THE PROGRESS OR TEMPORARY SUSPENSION OF WORK, SUITABLE BARRIERS, FENCES, SIGNS OR OTHER ADEQUATE PROTECTION, INCLUDING FLAGMEN AND WATCHMEN AS NECESSARY TO INSURE THE SAFETY OF THE PUBLIC AS WELL AS THOSE ENGAGED IN THE CONSTRUCTION WORK. CONSTRUCTION SIGNING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF "CONSTRUCTION AND MAINTENANCE OPERATIONS SUPPLEMENT TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" BY THE DOT. S. ALL MATERIAL.... CLEARED OR DEMOLISHED BY THE CONTRACTOR IN ORDER TO CONSTRUCT THE WORK SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE PROPERTY DISPOSED OF OFF -SITE. 6. ALL WORK BY THE CONTRACTOR SHALL BE WARRANTEED BY THE CONTRACTOR FOR A PERIOD OF ONE YEAR AFTER THE OWNER ACCEPTS THE WORK. 7. CONTRACTOR SHALL CALL THE NORTH CAROLINA ONE -CALL CENTER AT 1 (800) 632-4949 AND ALLOW THE CENTER TO LOCATE EXISTING UTILITIES BEFORE DIGGING. EXISTING UTILITY NOTES 1. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THE ACTUAL LOCATION ANt AVAILABILITY OF ALL EXISTING AND PROPOSED UTILITIES IN THE FIELD PRIOR TO GROUND BREAKING. SITE NOTES: 1. ANY DISCREPANCY IN THIS PLAN AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE OWNER PRIOR TO START OF CONSTRUCTION. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL SETBACKS, EASEMENTS AND DIMENSIONS SHOWN HEREON BEFORE BEGINNING CONSTRUCTION. 2. THE GENERAL CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, UTILITIES AND R.O.W.'S PUBLIC OR PRIVATE, PRIOR TO WORKING IN THESE AREAS. 3. CONTRACTOR SHALL MAINTAIN THE SITE IN A MANNER SO THAT WORKMEN AND PUBLIC SHALL BV PROTECTED FROM INJURY, AND ADJOINING PROPERTY PROTECTED FROM DAMAGE. 4. ACCESS TO UTILITIES, FIRE HYDRANTS, STREET LIGHTING, ETC., SHALT. REMAIN UNDISTURBED, UNLESS COORDINATED WITH THE RESPECTIVE UTILITY, 5. DO NOT SCALE THIS DRAWING AS IT IS A REPRODUCTION AND SUBJECT TO DISTORTION. 6. THE GENERAL CONTRACTOR SHALL REMOVE ALL DEBRIS FROM THE SITE UPON COMPLETION OF THE PROJECT AND AT LEAST ONCE A WEEK DURING CONSTRUCTION. 7. THE GENERAL CONTRACTOR SHALL KEEP THE AREA OUTSIDE THE "CONSTRUCTION LIMITS" BROOM CLEAN AT ALL TIMES. 8. ALL STREET SURFACES, DRIVEWAYS, CULVERTS, CURB AND GUTTERS, ROADSIDE DRAINAGE DITCHES AND OTHER STRUCTURES THAT ARE DISTURBED OR DAMAGED IN ANY MANNER AS A RESULT OF CONSTRUCTION SHALL BE REPLACED OR REPAIRED IN ACCORDANCE WITH THE SPECIFICATIONS. 9. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES. THE LOCATION OF ALL EXISTING UTILITIES ARE NOT NECESSARILY SHOWN ON PLANS AND WHERE SHOWN ARE ONLY APPROXIMATE. THE CONTRACTOR SHALL ON HIS INITIATIVE AND AT NO EXTRA COST HAVE LOCATED ALL UNDERGROUND LINES AND STRUCTURES AS NECESSARY. NO CLAIMS FOR DAMAGES OR EXTRA COMPENSATION SHALL ACCRUE TO THE CONTRACTOR FROM THE PRESENCE OF SUCH PIPE OTHER OBSTRUCTIONS OR FROM DELAY DUE TO REMOVAL OR REARRANGEMENT OF THE SAME. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO UNDERGROUND STRUCTURES. CONTACT NORTH CAROLINA ONE CALL" TOLL FREE 1-800-632-4949 AT LEAST 48 HOURS PRIOR TO CONSTRUCTION, THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING ALL NONSUBSCRIBING UTILITIES. 10. ALL PERMITS RELATIVE TO PROJECT MUST BE OBTAINED, PRIOR TO CONSTRUCTION. 11. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH PERMITS ISSUED AND APPLICABLE FEDERAL, STATE, COUNTY, AND LOCAL CODES. 12, THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL INSPECTIONS, CERTIFICATIONS, EQUIPMENT, ETC., THAT MAY BE REQUIRED. 13. THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THE CONSTRUCTION MEANS AND METHODS ASSOCIATED WITH THE PROJECT AS SET FORTH IN THESE PLANS._ ..... , s. 'Y. . ,',v. .'•j ,..f���� y y � N I > p 4 X WET IP1= IRI+ CMF C.] `..„.; TR ...._._,._ v,+ -- 6lv----Vi-.....w.... W..._._.,.__ y,w,_,.... . _-._...._;;S_...___ C.q._..T...._. 86,__.._ 35_-_..._ - w Ili{✓ OHE EXISTING PROPERTY LINE EXISTING EASEMENT PROPOSED CONCRETE SIDEWALK w PROPOSED BUILDING FOOTPRINT PROPOSED BUFFER AREAS PROPOSED LANDSCAPE ISLANDS = EXISTING TREE TO BE REMOVED WETLAND LINE IRON PIPE FOUND IRON ROD FOUND CONCRETE MONUMENT TELEPHONE PEDESTAL TRANSFORMER PEDESTAL (PAD) EXISTING WATER MAIN EXISTING SANITARY SEWER MAIN w EXISTING OVERHEAD ELECTRIC 29 29 EG-25. --�,� P =25.0 _- _ � TW=2s.o �� TC--25,05 ---,_� LOD EROSION CONTROL AND SEQUENCE OF CONSTRUCTION NOTES: NOTE: THESE EROSION CONTROL AND SEQUENCE OF CONSTRUCTION NOTES ARE INTENDED FOR EACH "PHASE" OF CONSTRUCTION. THE ORDER AND STEPS TAKEN MUST BE IMPLEMENTED AS EACH PART OF THE PROJECT IS DEVELOPED; WHETHER AS A WHOLE OR IN PHASES. ANY EROSION CONTROL DEVICES/MEASURES MUST REMAIN IN PLACE UNTIL THE ENTIRE BASIN DESIGNED TO HANDLE SEDIMENTATION AND EROSION IS STABILIZED AND ALL IMPROVEMENTS WITHIN THE BASIN ARE COMPLETE. 1. PRIOR TO ANY GRADING ACTIVITY, CONTRACTOR SHALL CONSTRUCT TEMPORARY GRAVEL CONSTRUCTION ENTRANCE(S), ESTABLISH THE LIMITS OF DISTURBANCE, AND TEMPORARY SILT FENCE. 2. CLEAR AND REMOVE FROM SITE ALL TREES (ONLY ONES TO BE REMOVED), ROOTS, ROOT MAT, ETC. FROM THE AREA WITHIN THE DESIGNATED CLEARING LIMITS. 3. INSTALL REMAINING EROSION CONTROL MEASURES AS SHOWN ON THE PLANS WITHIN THE AREA DISTURBED. ALL EROSION CONTROL MEASURES MUST BE INSTALLED BEFORE COMMENCING CONSTRUCTION. 4, WITHIN 90 DAYS FROM COMMENCEMENT OF CONSTRUCTION, CONTRACTOR SHALL INSTALL STORM DRAINAGE COLLECTION SYSTEM AND IMMEDIATELY UPON THE INSTALLATION OF ANY STORM DRAINAGE CATCH BASIN, DROP INLET, ETC., THE CONTRACTOR SHALL INSTALL INLET PROTECTION TO STOP ANY SEDIMENT FROM ENTERING THE DRAINAGE SYSTEM. S. IMMEDIATELY UPON THE INSTALLATION OF ANY STORM DRAINAGE SYSTEM, THE CONTRACTOR SHALL INSTALL INLET/OUTLET PROTECTION AS SHOWN ON THE PLANS AND DETAILS. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING AND RESTORING TO PRE-CONSTRUTION CONDITIONS ANY AREAS OUTSIDE THE PROJECT LIMITS THAT MAY INADVERTENTLY BE DAMAGED DUE TO THE FAILURE OF THE EROSION CONTROL MEASURES. 7. PLANT GRASS OVER ALL GRADED AREAS WITHIN 14 WORKING DAYS FOR FLATAREAS AND 7 CALENDAR DAYS FOR ALL SLOPES OF CEASE OF ANY GRADING ACTIVITY. 8. DURING GRADING AND AFTER GRADING HAS BEEN COMPLETED, THE CONTRACTOR SHALL CONTINUE TO MAINTAIN PERMANENT AND TEMPORARY EROSION CONTROL MEASURES UNTIL FINAL INSPECTION AND APPROVAL BY NCDENR. 9. UPON RECEIVING FINAL INSPECTION AND APPROVAL BY NCDENR, THE CONTRACTOR CAN REMOVE TEMPORARY EROSION CONTROL MEASURES. 10, THE CONTRACTOR SHALL CONTINUE TO WATER, FERTILIZE, MOW AND MAINTAIN SPRIGGED, SODDED, AND PLANTED AREAS UNTIL ALL CONSTRUCTION IS COMPLETE. GENERAL EROSION AND SEDIMENT CONTROL NOTES: 1. THE EROSION CONTROL PLAN SHALL INCLUDE PROVISIONS FOR GROUNDCOVER ON ALL EXPOSED PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES, ALL SLOPES STEEPER THAN 3:1, AND ALL DISTURBED AREAS WITHIN THE HQW LNE WITHIN 7 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY. GROUND COVER SHALL BE PROVIDED ON ALL OTHER DISTURBED AREAS WITHIN 14 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY. 2. UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONSTRUCTED AND MAINTAINED IN ACCORDANCE WITH THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL HANDBOOK, (NO SEPARATE PAYMENT). 3. THE CONTRACTOR SHALL NOTIFY PLAN APPROVING AUTHORITY ONE WEEK PRIOR TO THE PRECONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO FINAL INSPECTION. 4. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO CLEARING AND/OR LAND DISTURBANCE. THE TEMPORARY CONSTRUCTION ENTRANCE SHOULD BE THE FIRST MEASURE INSTALLED. 5. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN AND PERMIT SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. 6. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO OFF -SITE BORROW OR WASTE AREAS, STAGING OR STORAGE AREAS), THE CONTRACTOR SHALL PREPARE AND SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND TO NEW HANOVER COUNTY FOR APPROVAL. CONTRACTOR SHALL PAY ALL FEES REQUIRED AND SHALL INSTALL NECESSARY MEASURES AT NO SEPARATE PAYMENT. THE CONTRACTOR SHALL PROVIDE THE OWNER AND THE ENGINEER A COPY OF THE AMENDED PERMIT. 7. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTRC MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY EITHER THE REVIEWING AGENCY OR THE ENGINEER. (NO SEPARATE PAYMEENT). 8. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. 9. ALL AREAS DISTURBED BY CONSTRUCTION UNLESS OTHERWISE IMPROVED SHALL BE SODDED OR SEEDED AS INDICATED AND STABILIZED. 10. DURING DEWATERING OPERATIONS, WATER SHALL BE PUMPED INTO AN APPROVED FILTERING DEVICE PRIOR TO DISCHARGE TO RECEIVING OUTLET. 11. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF -PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. 12. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED BY CONTRACTOR ONCE STABILIZATION OR A SUFFICIENT GROUND COVER HAS BEEN ESTABLISHED OR AS DIRECTED BY THE ENGINEER. (NO SEPARATE PAYMENT). NCDENR FINAL APPROVAL IS REQUIRED. 13. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE SHALL BE REQUIRED AT ALL CONSTRUCTION STAGING AREA ENTRANCES AND ALL CONSTRUCTION ACCESS LOCATIONS INTO NON PAVED AREA. (NO SEPARATE PAYMENT). 14. WHEN CROSSING CREEK -OR DRAINAGE -WAY, THE DIVISION OF WATER QUALITY SHALL BE CONTACTED PRIOR TO DISTURBING A CREEK. THE CONTRACTOR SHALL INSTALL RIP -RAP WITH FABRIC ALONG DISTURBED BANKS AND CHANNEL AND RESTORE SLOPES TO ORIGINAL CONTOURS, BUT NOT STEEPER THAN 2:1 MAXIMUM. DISTURBED CREEK AREA SHALL BE STABILIZED IMMEDIATELY. EXISTING CONTOUR PROPOSED CONTOUR EXISTING SPOT ELEVATION PROPOSED EDGE OF PAVEMENT PROPOSED SIDEWALK ELEVATION PROPOSED TOP OF CURB ELEVATION INLET PROTECTION LIMITS OF DISTURBANCE SILT FENCE DRAINAGE FLOW PATH DRAINAGE INLET LABEL CURB INLET / DROP INLET (AS NOTED) PERMANENT SEEDING SCHEDULE .. MIXTURE 5CP Seeding Mixture SPECIES RATE (LB/ACRE) CENTIPEDE GRASS 10-20 Seeding Dates MARCH-JUNE Soil Amendments APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 300 LB/ACRE 10-10-10 FERTILIZER, Mulch DO NOT MULCH. Maintenance FERTILIZE VERY SPARINGLY--20 LB/ACRE NITROGEN IN SPRING WITH NO PHOSPHORUS. CENTIPEDE GRASS CANNOT TOLERATE HIGH PH OR EXCESS FERTILIZER. TEMPORARY SEEDING --LATE WINTER/EARLY SPRING Seeding Mixture WINTER AND EARLY SPRING SPECIES RATE (LB)ACRE) RYE (GRAIN) 120 ANNUAL LESPEDEZA (KOBE IN PIEDMONT AND COASTAL PLAIN, KOREAN IN MOUNTAINS) 50 OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE. SUMMER SPECIES RATE (LB/ACRE) GERMAN MILLET 40 FALL SPECIES RATE (LB)ACRE) RYE (GRAIN) 120 Seeding dates COASTAL PLAIN - DECA-APR. 15 - LATE WINTER AND EARLY SPRING APRIL 15 - AUG. 15 - SUMMER AUG. 15 - DEC. 30 - FALL Soil amendments FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LBIACRE GROUND AGRICULTURAL LIMESTONE AND 760 LBIACRE 10-10-10 FERTILIZER. Mulch APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. Maintenance REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE, RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. MAINTENANCE PLAN 1. ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY TO MAINTAIN ALL. PRACTICES AS DESIGNED. 2. ALL CONSTRUCTION ENTRANCES WILL BE PERIODICALLY TOP DRESSED WITH AN ADDITIONAL 2 INCHES OF #4 STONE TO MAINTAIN PROPER DEPTH. ANY SEDIMENT THAT IS TRACKED INTO THE STREET WILL BE IMMEDIATELY REMOVED. 3. SEDIMENT FENCE - SEDIMENT WILL BE REMOVED BEHIND THE SEDIMENT FENCE WHEN IT BECOMES 0.5 FEET DEEP AT THE FENCE. THE SEDIMENT FENCE WILL BE BE REPAIRED AS NECESSARY TO MAINTAIN A BARRIER, SILT FENCE STAKES WILL BE SPACED 6 FEET APART UNLESS A WIRE BACKING IS USED WITH 8 FOOT STAKE SPACING. 4. ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED ACCORDING TO SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A VIGOROUS, DENSE VEGETATIVE COVER. 5. INLET PROTECTION - INSPECT ROCK PIPE INLET PROTECTION AT LEAST ONCE A WEEK AND AFTER EACH SIGNIFICANT 4 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING. 6. SEDIMENT TRAPS / BASINS - REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN IT ACCUMULATES TO WITHIN ONE HALF OF THE DESIGN DEPTH. THE ROCK WILL BE CLEANED OR REPLACED WHEN THE SEDIMENT POOL NO LONGER DRAINS OR WHEN THE ROCK IS DISLODGED. BAFFLES WILL BE REPAIRED OR REPLACED PROMPTLY IF THEY COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE. SEDIMENT WILL BE REMOVED FROM BAFFLES WHEN DEPOSITS REACH HALF THE HEIGHT OF THE 1ST BAFFLE. FLOATING SKIMMERS WILL BE INSPECTED WEEKLY AND WILL BE KEPT CLEAN. PLACE SEDIMENT IN AN AREA WITH SEDIMENT CONTROLS. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, PIPING, AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE RISER AND POOL AREA. 7. OUTLET PROTECTION - INSPECT RIP RAP OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (4 INCH OR GREATER) RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE RIP RAP HAS TAKEN PLACE, OR IF STONES HAVE BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. 8. EMERGENCY SPILLWAY / FOREBAY PROTECTION - AFTER EVERY HIGH-WATER EVENT INSPECT THE INTEGRITY OF THE LINED SPILLWAY AND THE ADJACENT EARTHEN BANKS. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. REPAIR ANY VOIDS IN THE RIP RAP LINED APRONS, RE-ESTABLISH ANY LOOSE STONES, AND FIX GAPS IN THE ADJACENT VEGETATIVE COVER. 9. SKIMMER - INSPECT SKIMMER AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL TO MAKE SURE THAT THE INTAKE MECHANISM, ORIFICE, OR DISCHARGE PIPE IS NOT CLOGGED WITH TRASH OR SEDIMENT. IF THE BASIN IS DRY, MAKE SURE THAT ANY VEGETATION GROWING ON THE BOTTOM IS NOT HOLDING THE SKIMMER DOWN. TAKE SPECIAL PRECAUTION IN WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE, NC ACCESSIBILITY NOTES: GENERAL NOTES: 1. SPECIAL ATTENTION SHALL BE GIVEN TO COMPLIANCE WITH AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NORTH CAROLINA BUILDING CODE/ANSI A117.1, AND APPLICABLE LOCAL LAWS & REGULATIONS. 2. IT IS ESSENTIAL THAT CONTRACTORS ARE AWARE OF THE SITE ACCESSIBILITY REQUIREMENTS. PARAMOUNTE ENGINEERING, INC. (PEI) HAS DEVELOPED THESE NOTES AND DETAILS TO ASSURE THAT CONTRACTORS ARE AWARE OF THE REQUIREMENTS AT THE POINT IN TIME WHEN THEYARE BIDDING THE PROJECT. IN ADDITION, PEI HAS MADE A POINT IN THESE NOTES AND DETAILS, AS WELL AS IN OUR DRAWINGS, TO PROVIDE SLOPES / GRADES AND DIMENSIONS THAT COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NORTH CAROLINA BUILDING CODE/ANSI A117.1 AND APPLICABLE LOCAL LAWS & REGULATIONS. IF THESE SLOPES / GRADES AND DIMENSIONS ARE NOT ACHIEVABLE, THE CONTRACTOR IS REQUIRED TO CONTACT THE OWNER IMMEDIATELY AND BEFORE MOVING FORWARD WITH THE WORK. 3. THE CONTRACTOR SHALL NOTIFY PEI IMMEDIATELY OF ANY CONFLICT BETWEEN THESE NOTES AND DETAILS AND OTHER PROJECT DRAWINGS, WHETHER BY PEI OR OTHERS. THE CONTRACTOR SHALL NOT PROCEED WITH THE WORK FOR WHICH THE ALLEGED CONFLICT HAS BEEN DISCOVERED UNTIL SUCH ALLEGED CONFLICT HAS BEEN RESOLVED. NO CLAIM SHALL BE MADE BY THE CONTRACTOR FOR DELAY OR DAMAGES AS A RESULT OF RESOLUTION OF ANY SUCH CONFLICT(S), 4. THESE ACCESSIBILITY NOTES AND DETAILS ARE INTENDED TO DEPICT SLOPE AND DIMENSIONAL REQUIREMENTS ONLY. REFER TO SIDEWALK, CURBING, AND PAVEMENT DETAILS FOR ADDITIONAL INFORMATION. ACCESSIBLE ROUTE NOTES' 1. AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED WITHIN THE SITE FROM ACCESSIBLE PARKING SPACES AND ACCESSIBLE PASSENGER LOADING ZONES; PUBLIC STREETS OR SIDEWALKS; AND PUBLIC TRANSPORTATION STOPS TO THE ACCESSIBLE BUILDING OR FACILITY ENTRANCE THEY SERVE. 2. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, AND ACCESSIBLE SPACES THAT ARE ON THE SAME SITE. 3. WALKING SURFACES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL HAVE A MAXIMUM RUNNING SLOPE OF 5.0% AND A MAXIMUM CROSS SLOPE OF 2.0%. 4. ANY WALKING SURFACE THAT IS PART OF AN ACCESSIBLE ROUTE WITH A RUNNING SLOPE GREATER THAN 5.0% IS A RAMP AND SHALL COMPLY WITH THE GUIDELINES FOR RAMPS OR CURB RAMPS. 5. TRANSITIONS BETWEEN RAMPS, WALKS, LANDINGS, GUTTERS OR STREETS SHALL BE FLUSHAND FREE OF ABRUPT VERTICAL CHANGES (1/4 INCH MAXIMUM VERTICAL CHANGE IN LEVEL PERMITTED). 6. FLOOR SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT. 7. THE MINIMUM CLEAR WIDTH OF EXTERIOR ACCESSIBLE ROUTES SHALL BE FOURTY-EIGHT (48) INCHES MINIMUM MEASURED BETWEEN HANDRAILS WHERE HANDRAILS ARE PROVIDED (NG BUILDING CODE 1104.1 & 1104.2). 8. WHERE AN ACCESSIBLE ROUTE MAKES A 180 DEGREE TURN AROUND AN OBJECT THAT IS LESS THAN FORTY-EIGHT (48) INCHES IN WIDTH, CLEAR WIDTH SHALL BE FORTY-TWO (42) INCHES MINIMUM APPROACHING THE TURN, FORTY-EIGHT (48) INCHES MINIMUM DURING THE TURN, AND FORTY-TWO (42) INCHES MINIMUM LEAVING THE TURN. THE CLEAR WIDTH APPROACHING AND LEAVING THE TURN MAY BE THIRTY-SIX (36) INCHES MINIMUM WHEN THE CLEAR WIDTH AT THE TURN IS SIXTY (60) INCHES MINIMUM.. SEE NOTE 7 ABOVE FOR NC CLEAR WIDTH OF EXTERIOR ACCESSIBLE ROUTES" 9. AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN SIXTY (60) INCHES SHALLPROVIDE PASSING SPACES AT INTERVALS OF TWO HUNDRED (200) FEET MAXIMUM. PASSING SPACES SHALL BE EITHER SIXTY (60) INCH MINIMUM BY SIXTY (60) INCH MINIMUM SPACE; OR AN INTERSECTION OF TWO (2) WALKING SURFACES THAT PROVIDE A COMPLIANT T-SHAPED TURNING SPACE, PROVIDED THE BASE AND ARMS OF THE T-SHAPED SPACE EXTEND FORTY-EIGHT (48) INCHES MINIMUM BEYOND THE INTERSECTION. 10. DOORS, DOORWAYS AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NORTH CAROLINA BUILDING CODE/ ANSI A117.1, AND APPLICABLE LOCAL LAWS & REGULATIONS. 11. DIRECTIONAL SIGNAGE INDICATING THE ROUTE TO THE NEAREST ACCESSIBLE BUILDING ENTRANCE SHALL BE PROVIDED AT INACCESSIBLE BUILDING ENTRANCES.- 12. WHERE POSSIBLE, DRAINAGE IN SHALL NOT BE LOCATED ON AN ACCESSIBLE ROUTE. IN THE EVENT THAT A DRAINAGE INLET MUST BE LOCATED ON AN ACCESSIBLE ROUTE, THE GRATE SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), A117.1, THE NC BUILDING CODE, AND APPLICABLE LOCAL LAWS & REGULATIONS RAMP NOTES: 1. ANY PART OF AN ACCESSIBLE ROUTE WITH A RUNNING SLOPE GREATER THAN 5% SHALL BE CONSIDERED A RAMP. 2. THE MAXIMUM RUNNING SLOPE FOR A RAMP SHALL BE 8.33% AND THE MAXIMUM CROSS SLOPE SHALL BE 2.0%. 3. THE CLEAR WIDTH OF AN EXTERIOR RAMP RUN SHALL BE FORTY EIGHT INCHES (NC BUILDING CODE 1104.1). WHERE HANDRAILS ARE PROVIDED ON THE RAMP RUN, THE CLEAR WIDTH SHALL BE MEASURED BETWEEN THE HANDRAILS. 4. THE RISE FOR ANY RAMP RUN SHALL BE THIRTY (30) INCHES MAXIMUM. 5. LANDINGS SHALL BE PROVIDED AT THE TOP AND BOTTOM OF RAMPS. LANDINGS SHALL HAVE A SLOPE NOT STEEPER THAN 2.0% IN ANY DIRECTION. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE WIDEST RAMP RUN LEADING TO THE LANDING. THE LANDING CLEAR LENGTH SHALL.. BE SIXTY (60) INCHES LONG MINIMUM. RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR LANDING OF SIXTY (60) INCHES BY SIXTY (60) INCHES MINIMUM. 6. RAMP RUNS WITH A RISE GREATER THAN SIX (6) INCHES SHALL HAVE HANDRAILS ON BOTH SIDES COMPLYING WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NC BUILDING CODEIANSI A117.1, AND APPLICABLE LOCAL LAWS & REGULATIONS. 7 .FLOOR SURFACES OF RAMPS AND LANDINGS SHALL BE STABLE, FIRM AND SLIP RESISTANT. 8. EDGE PROTECTION COMPLYING WITH AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NC BUILDING CODEIANSI A117.1, AND APPLICABLE LOCAL LAWS & REGULATIONS SHALL BE PROVIDED ON EACH SIDE OF RAMP RUNS AND ON EACH SIDE OF RAMP LANDINGS. 9. WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS), THE NC BUILDING CODE/ANSI A117.1 SHALL BE PERMITTED TO OVERLAP THE REQUIRED LANDING AREA. WHERE DOORS THAT ARE SUBJECT TO LOCKING ARE ADJACENT TO A RAMP LANDING, LANDINGS SHALL BE SIZED TO PROVIDE A COMPLIANT TURNING SPACE. NPDES WATER QUALITY STABILIZATION TIME FRAMES SITE AREA DESCRIPTION STABILIZATION TIMEFRAME EXCEPTIONS PERIMETER DIKES, SWALES, DITCHES AND SLOPES 7 DAYS NONE HIGH QUALITY WATER (HQW) ZONES 7 DAYS NONE SLOPES STEEPER THAN 3:1 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED SLOPES 3:1 OR FLATTER 14 DAYS 7 DAYS FOR SLOPES GREATER THAN 50' IN LENGTH ALL OTHER AREAS WITH SLOPES FLATTER THAN 4:1 14 DAYS NONE, EXCEPT FOR PERIMETERS AND HQW ZONES NC ACCESSIBILITY NOTES CONT. CURB RAMP NOTES: 1. THE MAXIMUM RUNNING SLOPE OF A CURB RAMP SHALL BE 8.33% AND THE MAXIMUM CROSS SLOPE SHALL BE 2.0%. 2. COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO THE CURB RAMP SHALL NOT BE STEEPER THAN 5%. THE ADJACENT SURFACES AT TRANSITIONS AT CURB RAMPS TO WALKS, GUTTERS AND STREETS SHALL BE AT THE SAME LEVEL. 3. THE CLEAR WIDTH OF A CURB RAMP SHALL BE 36 INCHES (36) MINIMUM, EXCLUSIVE OF FLARED SIDES, IF PROVIDED. "NOTE NC BUILDING CODE REQUIRES EXTERIOR ACCESSIBLE ROUTES TO BE 48 INCHES MINIMUM WIDE (1104.1 & 1104.2).'' 4. LANDINGS SHALL BE PROVIDED AT THE TOP OF CURB RAMPS, THE CLEAR LENGTH OF THE LANDING SHALL BE THIRTY-SIX (36) INCHES MINIMUM, THE CLEAR WIDTH OF THE LANDING SHALL BE AT LEAST AS WIDE AS THE CURB RAMP, EXCLUDING FLARED SIDES, LEADING TO THE LANDING. LANDINGS SHALL HAVE A SLOPE NOT STEEPER THAN 2% IN ANY DIRECTION. 6. IF A CURB RAMP IS LOCATED WHERE PEDESTRIANS MUST WALK ACROSS THE RAMP, OR WHERE IT IS NOT PROTECTED BY HANDRAILS OR GUARDRAILS, IT SHALL HAVE FLARED SIDES. 6. WHERE PROVIDED, CURB RAMP FLARES SHALL NOT EXCEED 10%. 7. CURB RAMPS AND THE FLARED SIDES OF CURB RAMPS SHALL. BE LOCATED SO THAT THEY DO NOT PROJECT INTO VEHICULAR TRAFFIC LANES, PARKING SPACES OR PARKING ACCESS AISLES. CURBS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARED SIDES, 8. CURB RAMPS SHALL BE LOCATED OR PROTECTED TO PREVENT THEIR OBSTRUCTION BY PARKED VEHICLES. 9. IT IS RECOMMENDED TO PROVIDE CURB RAMPS WITH A TWENTY-FOUR (24) INCH DEEP DETECTABLE WARNING COMPLYING WITH 406.12 A117.1, EXTENDING THE FULL WIDTH OF THE RAMP. REFERTO DETECTABLE WARNING DETAILS AND NOTES FOR PLACEMENT, ORIENTATION AND NOTES. THE NC BUILDING CODE DOES NOT CURRENTLY REQUIRE DETECTABLE WARNINGS AT CURB RAMPS, NOR DO THE 2010 ADA STANDARDS - HOWEVER US DOT ADA REGULATIONS DO REQUIRE THESE, 10. FLOOR SURFACES OF CURB RAMPS SHALL BE DEEP GROOVED, Y2 INCH WIDE BY �/a INCH DEEP, ONE (1) INCH CENTERS TRANSVERSE TO THE RAMP, 11. WHERE PROVIDED, STOP LINES SHALL BE LOCATED IN ADVANCE OF CURB RAMP, 12. WHERE PROVIDED, PEDESTRIAN ACTIVATED SIGNALS SHALL BE LOCATED ADJACENT TO THE SIDEWALK AND NOT ON THE SIDEWALK. 13. WHERE PROVIDED, DRAINAGE INLETS SHALL BE LOCATED UPSTREAM OF CURB RAMPS AND NOT IN THE RAMP AREA. 14. CURB RAMP TYPE AND LOCATION ARE PER PLAN. PARKING SPACE NOTES: 1. ACCESSIBLE PARKING SPACES SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTES OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE BUILDING ENTRANCE. 2. ACCESSIBLE PARKING SPACES SHALL BE AT LEAST NINETY-SIX (96) INCHES WIDE. ACCESS AISLES SHALL BE 60 INCHES WIDE. ONE OF SIX ACCESSIBLE SPACES SHOULD PROVIDE A VAN ACCESSIBLE AISLE. THE AISLE SHOULD BE 96 INCHES WIDE (OR AND ACCESSIBLE SPACEIS 11 FEET.ACCESS AISLE IS FIVE FEET), WHERE PARKING SPACES AND ACCESS AISLES ARE MARKED WITH LINES, THE WIDTH MEASUREMENTS SHALL BE MADE FROM CENTERLINE OF THE MARKINGS. WHERE PARKING SPACES OR ACCESS AISLES ARE NOT ADJACENT TO ANOTHER PARKING SPACE. OR ACCESS AISLES MEASUREMENTS SHALL BE PERMITTED TO INCLUDE THE FULL WIDTH OF THE LINE DEFINING THE PARKING SPACE OR ACCESS AISLE. 3. PARKING ACCESS AISLES SHALL BE PART OF AN ACCESSIBLE ROUTE TO THE BUILDING OR FACILITY ENTRANCE AND SHALL COMPLY WITH PROVISIONS FORACCESSIBLE ROUTES. MARKED CROSSINGS SHALL BE PROVIDED WHERE THE ACCESSIBLE ROUTE MUST CROSS VEHICULAR TRAFFIC LANES. WHERE POSSIBLE, IT IS PREFERABLE THAT THE ACCESSIBLE ROUTE NOT PASS BEHIND PARKED VEHICLES. 4. TWO (2) ACCESSIBLE PARKING SPACES MAY SHARE A COMMON ACCESS AISLE. 5. ACCESS AISLES SHALL EXTEND THE FULL LENGTH OF THE PARKING SPACE THEY SERVE. 6. ACCESS AISLES SHALL BE MARKED SO AS TO DISCOURAGE PARKING IN THEM. 7. ACCESS AISLES SHALL NOT OVERLAP THE VEHICULAR WAY, ACCESS AISLES SHALL BE PERMITTED TO BE PLACED ON EITHER SIDE OF THE PARKING SPACE EXCEPTFOR ANGLED VAN PARKING SPACES WHICH SHALL HAVE ACCESS AISLES LOCATED ON THE PASSENGER SIDE OF THE PARKING SPACES. 8. FLOOR SURFACES OF PARKING SPACES AND ACCESS AISLES SERVING THEM SHALL BE STABLE, FIRM AND SLIP RESISTANT, ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACES THEY SERVE, CHANGES IN LEVEL ARE NOT PERMITTED. 9. PARKING SPACES AND ACCESS AISLES SHALL BE LEVEL WITH SURFACE SLOPES NOT EXCEEDING 2.0% IN ALL DIRECTIONS. 10. PARKED VEHICLE OVERHANGS SHALL NOT REDUCE THE REQUIRED CLEAR WIDTH OF AN ACCESSIBLE ROUTE. 11. PARKING SPACES FOR VANS AND ACCESS AISLES AND VEHICULAR ROUTES SERVING THEM SHALL PROVIDE A VERTICAL CLEARANCE OF NINETY-EIGHT (98) INCHES MINIMUM. SIGNS SMALL BE PROVIDED AT ENTRANCES TO PARKING. FACILITIES INFORMING DRIVERS OF CLEARANCES AND THE LOCATION OF VAN ACCESSIBLE PARKING SPACES. 12. EACH ACCESSIBLE PARKING SPACE SHALL BE PROVIDED WITH SIGNAGE DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. SIGNS SHALL BE INSTALLED AT A MINIMUM CLEAR HEIGHT OF SIXTY (60) INCHES ABOVE GRADE AND SHALL NOT INTERFERE WITH AN ACCESSIBLE ROUTE FROM AN ACCESS AISLE. SIGNS LOCATED WHERE THEY MAY BE HIT BY VEHICLES BEING PARKED SHALL BE INSTALLED/ WITH BOLLARD PROTECTION, 13. SIGNAGE AT ACCESSIBLE PARKING SPACES REQUIRED BY THE NC BUILDING CODE SECTION 1106.1 SHALL COMPLY WITH THE REQUIREMENTS OF NORTH CAROLINA GENERAL STATUTE 20-37.6 AND 136-30 AND THE NCDOT UNIFORM MANUAL ON TRAFFIC CONTROL DEVICES. A SEPARATE SIGN IS REQUIRED FOR EACH SPACE. SIGNS TO INDICATE THE MAXIMUM PENALTY MUST BE PROVIDED AT EACH ACCESSIBLE SPACE. 14. ACCESSIBLE PARKING SPACE, ACCESS AISLE STRIPING, AND INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE PAINTED BLUE (OR ANOTHER COLOR THAT CAN BE DISTINGUISHED FROM PAVEMENT), PASSENGER. LOADING ZONE NOTES: 1. PASSENGER LOADING ZONES SHALL PROVIDE VEHICULAR PULL-UP SPACE NINETY-SIX (96) INCHES WIDE MINIMUM AND TWENTY (20) FEET LONG MINIMUM. 2. PASSENGER LOADING ZONES SHALL PROVIDE A CLEARLY MARKED ACCESS AISLE THAT IS SIXTY (60) INCHES WIDE MINIMUM AND EXTENDS THE FULL LENGTH OF THE VEHICLE PULL-UP SPACE THEY SERVE, 3. ACCESS AISLE SHALL ADJOIN AN ACCESSIBLE ROUTE AND NOT OVERLAP THE VEHICULAR WAY. 4, VEHICLE PULL-UP SPACES AND ACCESS AISLES SERVING THEM SHALL BE LEVEL WITH SURFACE SLOPES NOT EXCEEDING 2.0% IN ALL DIRECTIONS. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE VEHICLE PULL-UP SPACE THEY SERVE. CHANGES IN LEVEL ARE NOT PERMITTED. 5. FLOOR SURFACES OF VEHICLE PULL-UP SPACES AND ACCESS AISLES SERVING THEM SHALL BE STABLE, FIRM AND SLIP RESISTANT. 6.VEHICLE PULL-UP SPACES, ACCESS AISLES SERVING THEM AND A VEHICULAR ROUTE FROM AN ENTRANCE TO THE PASSENGER LOADING ZONE, AND FROM THE PASSENGER LOADING ZONE TO A VEHICULAR EXIT SERVING THEM, SHALL PROVIDE A VERTICAL CLEARANCE OF ONE HUNDRED FOURTEEN (1 14) INCHES MINIMUM. ACCESSIBLE ENTRANCE NOTES: 1. ACCESSIBLE ENTRANCES SHALL BE PROVIDED AS REQUIRED BY THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS) AND THE NORTH CAROLINA BUILDING CODE, AND APPLICABLE LOCAL LAWS & REGULATIONS. 2. ENTRANCE DOORS, DOORWAYS AND GATES SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (2010 ADA STANDARDS) THE NC BUILDING CODE/ANSI A117.1 AND SHALL BE ON AN ACCESSIBLE ROUTE, -0 0ro Y__ z 0 H x F-1 0 x 0 w Q w <11 W a F-4 0 z z Q5 q X w 6l ------------ 0 W C� U X M Z N r) 6-4 9 ..4 P4 z I'-4 (/) w P4 0 h -i A 2 � C 0� , O (/) U. (/� I-_ W I4 _j U U U 44 �� rr) , Z � 't � 0 "-O 7 CIA N t`�'- � \0 4.J cis ,,I- ,�...4 G� 00 � 6n Q t.-- Cq Z Q.U6 � 0�= � U ,- ; 4 ('�'' 4.) id X M ', N L�- 2 z 04< � t ', , O t__ 94 1 �-e Z � $ c.;, 91� �, C U P4 r �' { I.-4 � (D 0 ZI4 0 Uz Z, In<w:�jv < ), [- Z N O r . < z C U_ F-- O p O w 3� ..a U €�(9p Z O ��{ ^Q' �j � E 9 � **0 \" "'W"""., SE 4\a L �i >> ' K 4>. , /11 �•> ' i ` _ . w °�• cr3 35 tih � � ` * lt� gam" '> AZE_ > 1t1111111111tlllSlti%%%%%%\ MOM 1 C ISO PEI ,LOB#: 15255.PE . ... ................. CURB UNDERDRAIN NOTE: (FINAL DESIGN BY OTHERS *THE CONTRACTOR/DEVELOPER SHALL DIRECTLY CONSULW/ THE GEOTECH. ENGINEER OF RECORD FOR FINAL GUIDANCE, DETAILS, AND SPECIFICATIONS PRIOR TO CONSTRUCTION. ACCORDING TO THE GEOTECH. LETTER (DATED 10/26/15), ECS CAROLINAS RECOMMENDS CURB UNDERDRAINS BE INSTALLED, AS FOLLOWS: THE UNDERDRAINS SHALL CONSIST OF 8" DIA. . ... . . ..... SLOTTED PIPE BEDDED IN #57 STONE WITH AT LEAST 4 INCHES OF COVER ON ALL SIDES. THE STONE SHALL BE WRAPPED WITH A NON -WOVEN GEOTEXTILE MATERIAL. THE CURB UNDERDRAINS SHALL BE INSTALLED 1 FOOT BELOW THE BobTTOM OF THE CURB SECTION AND SHALL EXTEND A MIN. OF 50 LF ON BOTH SIDES OF THE STORMWATER CATCH BASINS. THE CONTRACTOR SHALL TIE THE CURB UNDERDRAINS TO THE STORMWATER CATCH BASINS. . . ..... 7 __-42 42 PAD=42.00 PAD=42.10 PAD=42.10 PAD=42.00 PAD=42,20 FIAD=42.70 PAD=42,80 PAD=43.60 CURB UNDERDRAIN (TYP) [DESIGNED BY OTHER�] SEE NOTE DRAINAGE EASEMENT [HATCHED AREA] (TYP. Samti ROAD 0 41 (45PRIVATEROK9 - PAD=42.10 PAD=42.00 PAD=4210 PAD=42.10 PAD=42.00 PAD=42.40 ­-42 MWAWAW"j MAN WA WA WWWAN NWA DRAINAGE EASEMENT [HATCHED ARE ] (TYP.) fi i. ar NAP ,Z ..... ..... WETLANDS R41 PAD=42,10 PAD=42-40 FlAD=42AV- PAD=43.60 PAD=43.30 PAD=42,80 42 PAD=42.00 (2) 18" RCP (CL.111) W/ FES PAD=42.30 PAD=41-90 PAD=4'1 -80 PAD=41.90 45 LF @ 0.2% INV.DWN(S)=39.08 1-140 CD SS, / T muRRA YVILLE RD CROOKED PINE RD c� ow j VICINITY MAP (NOT TO SCALE) w . .. .... .. 42-:-- DCE3-14 wl. ...... imilli0IIIIIIIIII LEGEND: IN w..... ... ......... . . ___-... W sf W­_ W­­ ............. - ---- - MH-13 . . . . . . ROAD C 41__ C 3A ........ . . ... 6 B. EXISTING CONTOUR (45'PRIVATE ROM Sc -29 K PROPOSED CONTOUR 4; s CB - PROPOSED EASEMENT 4 43 RIP RAP APRON PAD-42,30 PAD=42,30 PAD=42,10 PAD----42,00 404 WETLANDS PAD=42.10 PAD=42,50 PAD42.10 PAD=42.00 -641 ce) PROPOSED STORM DRAIN STRUCTURE CB-28 PROPOSED STORM SEWER A DRAINAGE NOTES 1 DRAINAGE EASEMENT AND STORMWATER SYSTEM MAINTENANCE IS THE RESPONSIBILITY OF THE f DEVELOPER OR HOA, INCLUDING PONDS, PIPES, DCB-27 CB-26 AND INFILTRATION BASINS AND TRENCHES, 2. ALL IMPERVIOUS MUST DRAIN TO THE DESIGNED STORMWATER SYSTEM, PER THE APPROVED PAD=42.30 PAD-42.40 PAD=42.00 PAD=42-00 EGAD PAD=42.00 PAD=42.00 PLANS. 3. NO OBSTRUCTIONS ARE ALLOWED IN DRAINAGE EASEMENTS, INCLUDING FENCES, UTILITY EASE NT {TYP.) A cy) SITE DATA TABLE TOTAL SITE AREA, 48.4 AC (2,108,304 SI JPOSED DISTURBED AREA: 39.0 AC (1,698,840 SI ......... . . w 7- CB-30 ........... B . . . . . . . ........ r PROPOSED IMPERVIOUS: V_ MH-29 - ------ ...... w LOTS (120 @ 4,000 SF): 480,000 SF (11.02 AC ROAD B W ROADS: 147,600 SF (339 AC) J clj ......... (45PRIVATE ROM 41: . ......... _.�=Zl=.=.'.�l ..... .... . ....... OTHER: 42Z450 SF (0,97 AC r LLI TOTAL: 670,050 SF (15.38 AC C13-31 .......... J - - - ------- 4' 71 1: EXISTING SOIL TYPES: SEAGATE & MURVILI C-) 0 < PAD-12.30 PAD;z42,30 PAD=42.00 PAD=42.00 PAD=4220 PAD=42.00 PAD=42,00 ID-42.20 OUTLET #1 CL DETAIL) D, CB-10 10' WIDE A(;(;tbZ5 t3ftKM•15- (TyP.) 1 CL CL PA PAD;r42-10 PAP=-42-00 PAD=42-00 PAD=t2.20 F�IAD=42-00 PAD-12.00 PAII-42,20 •' � •• '-.�• ,""-^•. ,- . 1 `>^..h . "� • � Y1' ",,, ,_ Y @pn Y44. rYt y 4r ..f'j r ` 1 �MJ•^ l2 ; ; ( I' `� � "� � �' YI ( ( t ,l � ( ( i #YMMM� Nr o RIP RAP --//' APRON #7 CL (SEE DETAIL) >-=--42 'k 6 CB-60 CB-58 C13_5 .............. "i j­,­-­ ­j -. � 2-­1 ­­11 � _ ___�r?,o s ....... .. ... ... 41, EMERGENCY 41, ROAD A 41,_____ (45'PRIVATE ROM SPILLWAY #1 Balm 1 (SEE DETAIL) 5 m ( CB,55 aB -9 -42 CB-57 .... CI3-61 .......... C/) PAD=42.50 PAD-­42.40 PAD=42.40/ PAD=42.40 PADzA42.40 PAD=42.40 PADr-42,40 PAD'�zQ.40 Z J'A EXISTING 18 CULVERT TO 1.59EP 41.64EP RIP RAP REMAIN APRON #8 OUTLET (SEE DETAIL) i STRUCTUREQ 41.64EP (SEE DETAIL) J 41.6 EP 4 _L_ A _4 41 9EP . ...... ..... 37 S4 B(;) (41,42 _,I 41.64EP' EXISTING 24" RCP CULVERT TO BE REPLACED W/ (2) 41X8 0 1 %11 Iff 1.4UME1 WET BOX CULVERTS (WI HEADWALLS) PLACED 16 (41.52BC) DETENTION BELOW OW PAnr 0 - 13911 OPEN} POND#2 [75 LF @ 0.20% DITCH INV.UP(E)=3 7:4 'J, 5 DITCH INV.DWN(W)=37 30 P PIPE INV.UP(E)=3612IPE INV.DWN=35.97] EMERGENCY SPILLWAY #2 (SEE DETAIL) t---q C ECEIVE FE-11--j", 2� 4!5120163' BY: GRAPHIC SCALE 0 25 60 100 200 I..,I mw SCALE: 111=50' tfi co 2 zi tz 0 w X z Z 0 <11 I u P-4 �4 0 u 0 2 0 LL V) z V) C) z ui P4 U z 0 AC;-\ 00 z o I- t. -4 0 w o� U z o I� P; U Ell 0 z 0 U) 2 0 w 0 z LL z 00 F- (��(o Q z a, W w w W:Ezz 0 W uI�t�v z UT 0 CL 0 CL u- a cl W a 0 0 SEAL v\ �0 0 EAl_ r co 036236 C-300 PEE JOBM 15255.PE CN 0 w O w Z fL 0 0 LLJ Q) w z z W) cox Z 0 z C� 0 V) zLL C) z CO to z le's w �z P-4 P4 0 P4 z co 11 C-) z 0 U) D � oz U- O>*-' >O'-' z 5� I-- Q) 0 z w Zww ui 0 0 Z W -j 9 z mj;� ul w 9 (1) W OWKW �O<UJaH 0. 0 0- U� W C) (A 0 0 SEAL rr C-301 PEI JOBM 15255.PE z 0 LLf ou 7D 0 0 LL z z w z C) C) < �7 Cq CN QUO D z ot-- tr 4-J 00 z w g) z _4 c;,T__4 z 9 , 4 z w PL� 1 z �D C U z 0 P4 z <� u Z c) Uzz Lo 00 z 0 U) 0 0 ZO U_ co z 69 z cw) Z LU CL U'l bu, ") W!�i �e z zz -4 _u1j, 0 0 Z CL 0 0. E w SEAL C, A -5z) C-300A PSI JOBS: 15255.PE z 0 Lil 00(,) cN 0 z U. z w ON 00 r-- c 0 C) Z p z C) 0 V-4. t�c Lr) z PL� U rT L) C) cc:) I,- UU 0 0 00 z8 LL z w (9toL (D w Z'ti3Q z w Uj Z Z 0 ct. z 0 uj n uj 0 w z CL 0 D- W md Gl W 0 w 00 0 SEAL 0 C-3*OB PEI JOB#: 15265,PE 70'-1 30'R b 30'R SIGHT—/ Ir- SIGHT TRIANGLE TRIANGLE TYPICAL STREET INTERSECTION I 1 1.5 . 5 . 41 .11, NOT TO SCALE 45 FT R/W 221 SLOPES= 3:1 11- 111 1/4" PER FT 1/4" PER FT ........................ 1­1 10.51 1/2" PER FT SIDEWALK ---/ /_ 2"-SF9.5B SURFACE L MODIFIED VALLEY CURB 6111-1325.013 BASE 6" STONE UNDER CURBING TYPICAL LOCAL ROAD CROSS SECTION NOT TO SCALE ' SF9.5B SURFACE COURSE ' NCDOT CRUSHED STONE AGGREGATE SSE COURSE 100% ASTM D698 COMPACTED SUBGRADE* 100% ASTM D698 TO 12" DEPTH PAVEMENT SECTION NOT TO SCALE SLOPES= 3:1 10'SKIP LINES It TtLLVVV UK Wril I t: GORE LINE CCN N 10, WHITE 30 DIAGONAL LINE 4v EDGE LINE z 'x 2'MINI-SKIP LINES YELLOW OR WHITE YELLOW OR WHITE YELLOW OR WHITE CROSSWALK LINE TURN LANE LINE WHITE 15! WHITE STOP OR TRANSVERSE BAR *NOTE, WERE TWO WIDTHS ARE INDICATED, THE FIRST oo WIDTH APPLIES FOR A "NORMAL." WIDTH LINE. THE SECOND CENTER LINE WIDTH APPLIES FOR A "WIDE" LINE. VDEm LINES ARE REQUIRED WHEN DESIGNATED IN THE PLANS, OR WHEN IDIRECTED BY THE ENGINEER. YELLOW WHITE PAVEMENT MARKINGS LINE TYPES NOT TO SCALE MODIFIED VALLEY CURB NOT TO SCALE 6" AGGREGATE BASE COURSE UNDER CURB. A Intl ,D. 1/2" JOINT 1/8" RADIUS, TYP. SEALER DUMMY GROOVE EXPANSION JOINT CONTRACTION JOINT VARIES 3000 PSI CONCRETE 1/4" PER FT. 4 . 4. 4. SECTION VIEW f% )I 1/2" EXPANSION JOINT— MAX. 50'O.C. & BETWEEN STRUCTURES GROOVED CONTRACTION JOINT PLAN VIEW ON -SITE SIDEWALK DETAIL NOT TO SCALE In r% r-% A I A I I :NT 6 P-0)) VARIES 6 �_O)) FLUSH W/ ASPHALT I I SLOPE 4 4 4 4 4 14 HANDICAP RAMP NOT TO SCALE 51 -fi SIDEWALK N CURB 12:1 MAX, PAVEMENT SECTION A -A A WHEELCHAIR RAMP DROP CURB) NOT TO SCALE STAKEOUT POINT CURB INLET (STD. 840.03) FORM GUTTER TO MOD. VALLEY MATCH HOOD CURB & GUTTER 21 241 ---k--TRANSITION FROM MOD, CONTRACTOR SHALL VALLEY CURB & GUTTER TO MAINTAIN EOP & TRANSITION MATCH CURB INLET THE GUTTER LINE FOR CURB INSTALLATION INLET INSTALLATION CURB TRANSITION DETAIL NOT TO SCALE 0 uj Z (D (D 0 u 0 U- z I— C) z w P4 u 0 Z c) 4-) 00 va z 0 ItZ u w od c! t-- U Z w z �D (D wux Z 0 L__j 0 zz Z 0 cr_ 8 0 D 00 z U- z o z b 0 z UJ P u6i wo wci "A w Z Z y LLJ. 0 0 n:� �s 0� Z UJ z _j u3j: CL U tc tK CJ V1 c) 0 0 SE x 4, 036121 3 '13 ­4 C-6,oO SEED/ SOD ALL SLOPES ABOVE PERMANENT POOL EL. 6:1 SHELF BELOW PERMANENT POOL PLANTED WITH SUITABLE WETLAND SPECIES OR VEGETATION. 3 6 PERMANENT POOL EL 37.00 1211 3 T POND 1 SECTION NOT TO SCALE FILTER FABRIC SUITABLE PLANTS PICKERELWEED (PONTEDERIA CORDATA) DUCK POTATO (SAGGITARIA LATIFOLIA AND SAGGITARIA CARDINALIS) SWAMP ROSE (HIBISCUS MOSHEUTOS) BLUE FLAG (IRIS VIRGINICA) CARDINAL FLOWER (LOBELIA CARDINALIS) WET DETENTION POND PLANTING CONTRACTOR TO INSTALL ON THE 6:1 SLOPED SHELF, EQUAL NUMBERS OF EACH OF THE LISTED SUITABLE PLANTS. DURING INSTALLATION, GROUP SIMILAR SPECIES OF PLANTS TOGETHER. INSTALL PLANTS 24" O.C. IN A CHECKERBOARD PATTERN. 20 - 6" -FHIGK C;LAbb'tJ'KIV-KAV BASE BID EMERGENCY #1 SPILLWAY DETAIL NOT TO SCALE FILTER FABRIC EL. 41.00 (2) 36" RCP PIPE INSIDE AIS SPEC PRIMARY SPILLWAY - TOP OF RISER = 37.60 Q'XT GRATE OPENING) 4" SCH. 40 PVC - DRAWDOWN ORIFICE NORMAL POOL EL. = 37,00 YZI PLAN VIEW GALVANIZED BAR GRATING 1"x 1/8"BEARING BARS. FASTEN WITH J-CLIPS, ATTACH TO A I 114"x 11/4" x 1/4" GALVANIZED ANGLE FRAME. MORTOR FRAME TO TOP OF OUTLET STRUCTURE-- ' SEED/ SOD ALL SLOPES ABOVE PERMANENT POOL EL. 6:1 SHELF BELOW PERMANENT POOL PLANTED WITH SUITABLE WETLAND SPECIES OR VEGETATION. 61 PRECAST CONCRETE STRUCTURE. PERMANENT POOL EL 38.00 CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ENGINEER PRIOR TO 1211 ORDERING STRUCTURE POND SECTION NOT TO SCALE SUITABLE PLANTS PICKERELWEED (PONTEDERIA CORDATA) DUCK POTATO (SAGGITARIA LATIFOLIA AND SAGGITARIA CARDINALIS) SWAMP ROSE (HIBISCUS MOSHEUTOS) BLUE FLAG (IRIS VIRGINICA) CARDINAL FLOWER (LOBELIA CARDINALIS) WET DETENTION POND PLANTING CONTRACTOR TO INSTALL ON THE 6:1 SLOPED SHELF, EQUAL NUMBERS OF EACH OF THE LISTED SUITABLE PLANTS. DURING INSTALLATION, GROUP SIMILAR SPECIES OF PLANTS TOGETHER. INSTALL PLANTS 24" O.C. IN A CHECKERBOARD PATTERN. \1 (2) 36" CULVERT -/ OUTLET PIPE (2) 36- RCP (CL.111) INV. UP = 37.00 INV. DOWN = 37.00 SLOPE = 0 00% LENGTH=40 LF PROVIDE WIRE MESH OVER BOTHi", ENDS OF PIPE TO PREVENT REINFORCED CONCRETE BOX ORIFICE CLOGGING WITH DEBRIS. (CONTRACTOR SHALL SIZE FOR 610 TXT TOP GRATE OPENING) 6" EXTENDED BASE (AS REQ'D.) NOTES: SECTION A -A 1. FOR MAINTENANCE EFFORTS OR IN CASE OF EMERGENCY, STORMWATER STORED BELOW PERMANENT POOL SHALL BE PUMPED. OUTLET STRUCTURE #1 2. ALL STORMWATER (INCLUDING ROOF DRAINAGE) MUST BE CONVEYED TO THE STORMWATER BMP. NOT TO SCALE TOP EL. FOREBAY BERM 36,50 10' WIDE TOP OF BERM 1.5'RUNOFF STORAGE EL. = 37.56 PERMANENT POOL EL. (NORMAL WATER SURFACE) 37.00 a. I A 3 3 3 FOREI 1 FOREBAY POND SEDIMENT REMOVAL EL. = 31.00 SEDIMENT REMOVAL EL. = 31.00 1' OF POND DEPTH IS FOR BOTTOM EL. FOREBAY = 30.00 POND BOTTOM EL. = 30.00 SEDIMENT ACCUMULATION FOREBAY IS DIVIDED FROM THE PER DWQ POLICY MAIN POND BY AN EARTHEN & RIP RAP BERM POND 1 - FOREBAY AND STORAGE POND SECTION NOT To SCALE POND 1 DETAILS 20' 6" THICK UI_AZiZ5'b'KII`-KAV BASE BID EL. 42.00 GALVANIZED BAR GRATING T' x 1/6'BEARING BARS. FASTEN WITH J-CLIPS, ATTACH TO A I 1/4"x I 1/4"x 1/4" GALVANIZED ANGLE FRAME. MORTOR FRAME TO TOP OF OVERFLOW STRUCTURE (SEE DETAIL) VEG SHELF 6' J SLOPE TYP. AROUND POND PRIMARY SPILLWAY OUTLET STRUCTURE,,,, - TOP OF RISER = 39.75 (4'X4' GRATE OPENING) 3" SCH. 40 PVC OUTLET PIPE DRAWDOWN ORIFICE (1) 36- CULVERT (1) 36- RCP (CL.111) INV. UP = 38.00 NORMAL POOL EL. = 38.00 INV. DOWN = 38-00 SLOPE = 0.00% LENGTH=1372 LF EMERGENCY #3 SPILLWAY DETAIL PROVIDE WIRE MESH OVER BOTH-",., ENDS OF PIPE TO PREVENT REINFORCED CONCRETE BOX NOT TO SCALE ORIFICE CLOGGING WITH DEBRIS. (CONTRACTOR SHALL SIZE FOR 6tv I 4'x4' TOP GRATE OPENING) om/ 0 6" EXTENDED BASE (AS REaD.) SECTION A -A OUTLET STRUCTURE #3 NOT TO SCALE OFF -SITE BYPASS SYSTEM DETAILS FILTER FABRIC 6" THICK CLASS WRIP-RAP BASE BID EMERGENCY SPILLWAY #2 DETAIL NOT TO SCALE EL. 41.00 (2) 36- RCP PIPE MORTERED INSIDE AND OUT PER SPECIFICATIONS PLAN VIEW PRECAST CONCRETE STRUCTURE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ENGINEER PRIOR TO ORDERING STRUCTURE GALVANIZED BAR GRATING I" x I/8"BEARING BARS. FASTEN WITH J-CLIPS, ATTACH TO A 1 1/4" x 11/411 x 1/4" GALVANIZED ANGLE FRAME. MORTOR FRAME TO TOP OF PRIMARY SPILLWAY OUTLET STRUCTURE/ - TOP OF RISER = 38-95 (TXT GRATE OPENING) 3" SCH. 40 PVC OUTLET PIPE DRAWDOWN ORIFICE (2) 36" CULVERT -/ (2) 36" RCP (CL.111) INV. UP = 38.00 NORMAL POOL EL. = 38.00 INV. DOWN = 38,00 �_7 SLOPE = A AM - LENGTH=38 LF PROVIDE WIRE MESH OVER BOTH ENDS OF PIPE TO PREVENT REINFORCED CONCRETE BOX ORIFICE CLOGGING WITH DEBRIS. (CONTRACTOR SHALL SIZE FOR 611 7'xTTOP GRATE OPENING) '4kt 6" EXTENDED BASE Aga (AS REQ'D.) NOTES: SECTION A -A 1, FOR MAINTENANCE EFFORTS OR IN CASE OF EMERGENCY, STORMWATER STORED BELOW PERMANENT POOL SHALL BE PUMPED. OUTLET STRUCTURE #2 2. ALL STORMWATER (INCLUDING ROOF DRAINAGE) MUST BE NOT TO SCALE CONVEYED TO THE STORMWATER BMP. TOP EL, FOREBAY BERM 37.60 01 WIDE TOP OF BERM 1.5" RUNOFF STORAGE EL. = 38.92 7 PERMANENT POOL EL. (NORMAL WATER SURFACE) 38.00 3 3 3 w W w FOREBAY 1 1MAIN POND taSEDIMENT REMOVAL EL. = 32.00 SEDIMENT REMOVAL EL. = 32.00 VOF POND DEPTH IS FOR BOTTOM EL. FOREBAY = 31.00 POND BOTTOM EL. = 31.00 SEDIMENT ACCUMULATION FOREBAY IS DIVIDED FROM THE PER DWQ POLICY MAIN POND BY AN EARTHEN & RIP RAP BERM POND 2 - FOREBAY AND STORAGE POND SECTION NOT TO SCALE POND 2 DETAILS UP - Nude DWN Node Material Diameter (in) Length (ft) UP I twert (ft) DV' N I nve rt (ft) Slope UP Rim Elev (ft) DV%fNRim E1ev((k) CB 7 CB 6 *HDPE f RCP CL. III is 22 37.50 37.25 1.14 40.74 4R74 CB, 6 CB 5 *HDPE f RCP CL.111 24 140 36.30 34.40 1.36 40.74 _.4176 CB 5 CB 4 *HDPE f RCP CL.111 54 54 $1.90 31.70 0.37 41.76 41,40 CB, 4 DCB, 3 *HDPE f RCP CL. It 1 54 126 31.70 31.30 0.32 41.40 40.72 DCB 3 CB 2 *HDPE f RCP CL. 111 54 22 31.30 31.20 OAS 40.72 40.72 CB 2 FES I *HDPE f RCP CL.Ill 54 62 $1.20 31.00 0.32 40.72 31.00 CB, 9 CB 8 *HDPE f RCP CL.111 15 22 37.70 37.50 0.91 40.72 40.72 CB 8 CB 6 *HDPE f RCP CL.111 18 193 37.25 36.30 0.49 40.72 40.74 CB 11 CB 10 *HDPE f RCP CL.111 15 22 $7.25 37.00 1.14 40.72 40.72 CB 10 DCB 3 *HDPE f RCP CL.111 18 248 36.75 34.30 0.99 40.72 40,72 CB 12 CB 10 *HDPE f RCP CL.111 15 61 37.75 37.00 1.22 41.03 40,72 CB 22 CB 21 *HDPE f RCP CL.111 18 22 37.50 37.25 1.14 42.30 42.30 CB 21 CB 20 *HDPE f RCP CL. III is 7 1,4 A 35,75 35.10 0.37 42,30 41.22 CB 20 CB 18 *HDPE f RCP CL.111 36 75 35.10 34.85 0.33 41.22 40.86 CB 3.8 DCB 16 *HDPE f RCP CL.111 48 252 34,85 34.05 0.32 40.86 40.72 DCB 16 DCB 14 *HDPE f RCP CL.111 48 195 34-05 33.45 0.81 40.72 40.71. DCB 14 CB 13A *HDPE f RCP CL.111 48 143 33.45 33.00 0.31 40.71 41.47 CB 13A MH 13 *HDPE f RCP CL.111 48 32 33.00 32.90 0.31 41.47 41.78 MH 13 CB 5 *HDPE f RCP CL.111 48 331 32.90 31.90 0.30 41.78 41-76 CB 25 CB 24 *HDPE f RCP CL.111 15 22 37.35 37-13 1.00 40.711 40.71 ------ CB 24 CB 23 *HDPE f RCP CL.111 24 83 37.13 36.30 0.99 40.71 41.13 CD 28 CB 20 *HDPE f RCP CL.111 36 60 36.30 36.00 0.50 41-13---l- 41.22 CB 28 DCB, 27 *HDPE f RCP_ CL.111 15 61 36.50 35.45 112 41.02 40.72 - DCB 27 CB 26 *HDPE f RCP CL.111 18 22 35.20 34.95 1.14 40.72 40.72 - CB 26 MH 13 *HDPE f RCP CL.111 48 163 33.45 32.90 0.34 40.72 41.78 CB 31 CB 30 *HDPE f RCP CL.111 15 22 37.50 37.25 1.14 41,12 41.12 cB, so MH 29 *HDPE f RCP CL.111 48 34 34.00 33.80 0.57 41.12 41.47 MH # 29 CB 26 *HDPE f RCP CL.111 48 118 33.80 33.45 1 0,30 41.47 40.721 CB 37 CB 36 *HDPE /_RCP CL. III is 1 22 37.50 37.39 0.50 140.7fi 40.76 OVERFLOW STRUCTURE (SEE DETAIL) VEG SHELF 6:1 SLOPE TYP. AROUND POND CB 36 DCB 34 *HDPE f RCP CL.111 24 190 36.80 36.20 0.32 40.76 40.72 DCB 34 DCB 32 *HDPE f RCP CL.111 36 192 36.20 34.55 0.86 40.72 40.72 DCB 32 CB 30 *HDPE f RCP CL.111 26 183 34.55 34.00 0,30 40.72 41.12 CB 54 CB 53 *HDPE f RCP CL. III is 22 37,50 37.25 1.14 40.82 40.82 CB 53 MH 52 *HDPE f RCP CL. If 1 30 88 32,00 31.65 0.40 40.82 41.83 MH 52 MH 51 *HDPE f RCP CL.111 48 138 31.65 31.20 0.33 41,83 42.02 MH 51 FES 50 *HDPE f RCP CL.111 48 51 31.20 31,00 0.39 42.02 31.00 CB 56 CB 55 *HDPE f RCP CL. If 1 15 22 37.70 37.50 0.91 40.72 40.72 CB 55 CB 53 *HDPE f RCP CL.111 30 131 32.50 32.00 0.38 40.72 40.82 CB 58 CB 57 *HDPE f RCP CL.111 15 22 37.50 37.25 1.14 40.72 40.72 CB 57 CB, 55 *HDPE f RCP CL.111 1 24 188 33.20 32.50 0.37 40.72 40.72 CB 60 CB 59 *HDPE f RCP CL.111 15 22 37.50 37.25 1.14 40, 70 40.70 CB 59 CB 57 *HDPE f RCP CL.111 24 185 34.00 33.20 0.43 40.70 40,72 CB 62 CB 61 *HDPE f RCP CL. III is 22 37.50 37.25 1.13 40.73 40.73 CB 61 CB 59 *HDPE f RCP CL.111 15 40 34,25 34.00 0.63 40.73 40.70 CB 65 CB 64 *HDPE f RCP CL.111 15 22 37.50 37.25 1.14 40.95 40.95 CB 64 MH 63 *HDPE f RCP CL. 111 42 166 32.45 31.95 0.30 40.95 42.76 MH 63 MH 52 *HDPE f RCP CL.111 42 91 31.95 31.65 0.33 42.76 41.83 CB 68 CB 67 *HDPE f RCP CL.111 15 22 37,50 37.25 1.14 41.55 41.55 CB 67 rvIH 66 *HDPE f RCP CL.111 36 31 32.90 32.80 0.32 41.55 41,84 MH 66 CB 64 *HDPE f RCP CL.111 36 115 32,80 32.45 0.30 41.84 40.95 CB 70 CB 69 *HDPE f RCP CL.111 15 22 37-70 37.50 0.93 4115 41.14 CB 69 CB 67 *HDPE f RCP CL.111 24 315 33.85 32.90 0.30 4114 41.55 DCB 15 DCB 14 *HDPE f RCP CL.111 15 22 37.50 37,25 1.14 40.71 40.71 M 17 DCB 16 *HDPE f RCP CL.111 15 22 37.50 37.25 1.14 40.72 40.72 DCB 19 CB 18 *HDPE f RCP CL. If 1 15 22 37.50 37.25 1.14 40.86 40-86 DCB 33 DCB 32 *HDPE RCP CL.111 15 22 37,50 37.25 1.14 40.72 40.72 DCB 35 DCB 34 *HDPE f RCP CL.111 15 22 37.50 37.25 1,14 40.72 40.72 DCB 39 CB 38 *HDPE f RCP CL.111 18 22 37-50 37.00 2.27 40.72 40,72 CB 38 MH 29 *HDPE f RCP CL.111 18 130 37.00 35.30 1.30 40,72 41.47 DCB 72 CB 71 *HDPE f RCP CL.111 15 22 1 37.50 1 37.25 1 1,14 1 40.81 40.81 CB 71 CB 69 *HDPE f RCP CL.111 1 18 65 1 35.00 1 3410 1.38 40.81 41.14 ALL HDPE PIPE SHALL BE ADS N-12 HP STORM PIPE OR APPROVED EQUAL AND SHALL BE INSTALLED TO MANUFACTURER SPECIFICATIONS STORM SEWER SCHEDULE 6� z 0 u z 1_­I z 0 Y_ 0 0 U 0 U- z i:: (D z w P4 u 410 z z 0 A> V4 w Lu 03 z, (1) or- z 0 Z w 1T*) ti u -eel u r z x (0 Z:5: C) 0V z 04 0 U) 0 0 I. 00 0 uz- z 0 w 0 LL0 Lu @ a 0 z 0 tla w w (3- 0 (Lu �� a 0) ru z w SEAL sP \A UA i:) 0-4 W N NiA C-6,w3 PEI JOBM 15255.PE AND 4311 NOTE: USE TYPE "E"s 'OF" "0" GRATE UNLESS OTHERWISE NOTED. FRAME,GRATE, & HOOD ASS'Y AA > -- --- -- LAW ALIGN FRAME WITH INSIDE EDGE OF WALL TO ALLOW FOR VERTICAL ADJUSTMENT WALL SECTION UPTION 8B INSIDE ALLOW L T:0HAL1 OW UST MT ME Mu L M FOW PLAN if- 6"1 2'-0" 14% 2# - 111,42 R dO HOOD ELEVATION T Jf T-1 , 11., TA WCIION r. LL _F $E .0 PP z 0 3A p Pta W<bnE 0 00 2 " I.- " lm�_ 3: Z UJ N Wf­uo_j cco" V.Q I 10 0, - is Q) z CL a W 0 INCIZON .N z x 1�- 0 C? N cc cr. _,11 to z !MC mom - i W anj 31, R z f— UJ cc _T OR V- -4 4W SHEET I Of 2 SECTION - N 840,03 N C14 om < DETAIL SHOWING TYPES OF GRATES Z hit vs 0 USE ACCORDING TO WATER FLOW. om 0, > " "Wo r- on u__j&"z M= :Z-i oocoa: -i > no LA U_ ;_q m TYPE "E" PE 'IF" A Teal) Pogois A < is "tt (000 MIN X z x E 19 1 *.j"u r_ m 2 0 cc u- c'o WATER FLOW SAG -4 WATER FLOW I z " > uu rA. > < - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - lit t_: it UJ In CI z B 1 1`2f - - .................. - - - - - - - - - - - - - - - - - - - 11/211 ft SECTION B-8 ------------------------------------ z _n gn " =21/4 it L 0 co WATER FLOW SAG WATER FLOW 9 SECTION A -A 0 3: z m m ga 0 3: "it I""I-ff PE E #_4 z TYPE FTYPE ETYPEa, I-- ca RAISED FLOW ARROW 1z It Z--X16 HIGH in - - RAISED FLOW ARROW 24.4 CC m it HIGH 01 < ca 0 co > I 1W (b 11/2 14 Lu Lu X in 0 CD =3 -n 11 11/21? z to It /2"R 1/2 1% t--- , z 21-1134".. .1b. J 1/2 1-1 j 11 u u j -.I jiff k\\\ It SECTION A -A YL 3�,o SHEET 2 OF 2 840.03 SECTIONA-A SHEET 2 OF 2 03 TYPE G CT m= x > 0030m -n > xo)c)o Z "m r-"n 0 ;73 >> z 1c, SHEET i OF 2 840.02 BACK OF CURB -0— x - -Ir v_* X WC-T 1-9 t L _Y_ Y RISER "T. VARIES WHERE 30" TO 30" PIPE 18 USED RISER HT. VARIES --A WHERE 42" TO 64" PIPE IS USED DETAIL HfWNING METHOD E j R C STF bV_1ff6ER C NSTRUCTION SECTION X-X RENERAL NOTES* USE CLASS 'IS" CONCRETE THROUGHOUT. PROVIDE ALL CATCH BASIN$ OVER W-O" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WtUCH COMPLY WjTfj $TO. DRAWING 840.66. OPTIONAL CONSTRUCTION - NONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT IV CENTERS As DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB As SHOWN ON STD. NO. 040.00. USE TYPE "E", -F- AND "W CRATES UNLESS OTHERWISE INDICATED. FOR 8'-0" IN HEIGHT OR LESS USE 8" WALLS AND BOTTOM SLAB. OVER 8'.011 TO 16'-0" IN HEIGHT USE all WAL0 AND BOTTOM SLAB. ADJUST QUANTITIES ACCORDINGLY. CONSTRUCT WITH PIPE CROWS MATCHING. Qf0fER ALL EXPOSED CORNERS I". DRAWING NOT TO SCALE. 6" O Ll _j WHERE 30" TO 36- PIPE 18 USED SEE NOTE p 1_ SECTION_ m-m WHERE 42" TO 04" PIPE 18 USED m m A I :-A PLAN AC 0 LL z ui CL CL cc 4c U) A0, cc z < C-4 v- C) z uj 840.k2j two 611 6## 6r 6" L M FOW PLAN if- 6"1 2'-0" 14% 2# - 111,42 R dO HOOD ELEVATION T Jf T-1 , 11., TA WCIION r. LL _F $E .0 PP z 0 3A p Pta W<bnE 0 00 2 " I.- " lm�_ 3: Z UJ N Wf­uo_j cco" V.Q I 10 0, - is Q) z CL a W 0 INCIZON .N z x 1�- 0 C? N cc cr. _,11 to z !MC mom - i W anj 31, R z f— UJ cc _T OR V- -4 4W SHEET I Of 2 SECTION - N 840,03 N C14 om < DETAIL SHOWING TYPES OF GRATES Z hit vs 0 USE ACCORDING TO WATER FLOW. om 0, > " "Wo r- on u__j&"z M= :Z-i oocoa: -i > no LA U_ ;_q m TYPE "E" PE 'IF" A Teal) Pogois A < is "tt (000 MIN X z x E 19 1 *.j"u r_ m 2 0 cc u- c'o WATER FLOW SAG -4 WATER FLOW I z " > uu rA. > < - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - lit t_: it UJ In CI z B 1 1`2f - - .................. - - - - - - - - - - - - - - - - - - - 11/211 ft SECTION B-8 ------------------------------------ z _n gn " =21/4 it L 0 co WATER FLOW SAG WATER FLOW 9 SECTION A -A 0 3: z m m ga 0 3: "it I""I-ff PE E #_4 z TYPE FTYPE ETYPEa, I-- ca RAISED FLOW ARROW 1z It Z--X16 HIGH in - - RAISED FLOW ARROW 24.4 CC m it HIGH 01 < ca 0 co > I 1W (b 11/2 14 Lu Lu X in 0 CD =3 -n 11 11/21? z to It /2"R 1/2 1% t--- , z 21-1134".. .1b. J 1/2 1-1 j 11 u u j -.I jiff k\\\ It SECTION A -A YL 3�,o SHEET 2 OF 2 840.03 SECTIONA-A SHEET 2 OF 2 03 TYPE G CT m= x > 0030m -n > xo)c)o Z "m r-"n 0 ;73 >> z 1c, SHEET i OF 2 840.02 BACK OF CURB -0— x - -Ir v_* X WC-T 1-9 t L _Y_ Y RISER "T. VARIES WHERE 30" TO 30" PIPE 18 USED RISER HT. VARIES --A WHERE 42" TO 64" PIPE IS USED DETAIL HfWNING METHOD E j R C STF bV_1ff6ER C NSTRUCTION SECTION X-X RENERAL NOTES* USE CLASS 'IS" CONCRETE THROUGHOUT. PROVIDE ALL CATCH BASIN$ OVER W-O" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WtUCH COMPLY WjTfj $TO. DRAWING 840.66. OPTIONAL CONSTRUCTION - NONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT IV CENTERS As DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB As SHOWN ON STD. NO. 040.00. USE TYPE "E", -F- AND "W CRATES UNLESS OTHERWISE INDICATED. FOR 8'-0" IN HEIGHT OR LESS USE 8" WALLS AND BOTTOM SLAB. OVER 8'.011 TO 16'-0" IN HEIGHT USE all WAL0 AND BOTTOM SLAB. ADJUST QUANTITIES ACCORDINGLY. CONSTRUCT WITH PIPE CROWS MATCHING. Qf0fER ALL EXPOSED CORNERS I". DRAWING NOT TO SCALE. 6" O Ll _j WHERE 30" TO 36- PIPE 18 USED SEE NOTE p 1_ SECTION_ m-m WHERE 42" TO 04" PIPE 18 USED m m A I :-A PLAN AC 0 LL z ui CL CL cc 4c U) A0, cc z < C-4 v- C) z uj 840.k2j two 611 6## 6r 6" X WC-T 1-9 t L _Y_ Y RISER "T. VARIES WHERE 30" TO 30" PIPE 18 USED RISER HT. VARIES --A WHERE 42" TO 64" PIPE IS USED DETAIL HfWNING METHOD E j R C STF bV_1ff6ER C NSTRUCTION SECTION X-X RENERAL NOTES* USE CLASS 'IS" CONCRETE THROUGHOUT. PROVIDE ALL CATCH BASIN$ OVER W-O" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WtUCH COMPLY WjTfj $TO. DRAWING 840.66. OPTIONAL CONSTRUCTION - NONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT IV CENTERS As DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB As SHOWN ON STD. NO. 040.00. USE TYPE "E", -F- AND "W CRATES UNLESS OTHERWISE INDICATED. FOR 8'-0" IN HEIGHT OR LESS USE 8" WALLS AND BOTTOM SLAB. OVER 8'.011 TO 16'-0" IN HEIGHT USE all WAL0 AND BOTTOM SLAB. ADJUST QUANTITIES ACCORDINGLY. CONSTRUCT WITH PIPE CROWS MATCHING. Qf0fER ALL EXPOSED CORNERS I". DRAWING NOT TO SCALE. 6" O Ll _j WHERE 30" TO 36- PIPE 18 USED SEE NOTE p 1_ SECTION_ m-m WHERE 42" TO 04" PIPE 18 USED m m A I :-A PLAN AC 0 LL z ui CL CL cc 4c U) A0, cc z < C-4 v- C) z uj 840.k2j two 611 6## 6r 6" CLR. TYP o ... 8 #4 REBARS - ---------- - IUU _j 0 io 13" 1 > 31' 06 REBARS 12" J� z SECTION 'A -A' cc _j 0 'Ll + 11-011 - B 7 R, A A #4 RIBARS X7. 7 C- J WAFFLE WALL PLAN VIEW m z c Col-10 r_ o -T1 m z v o o 3: -n 2': M m Z w xo -0 r_ _n o 004-4 > > co ,#4 REBARS- uj 0 I , THE PATTERN OF THE (o KNOCK -OUT 1 PANELS ARE SHOWN FOR ILLUSTRATIVE I :.1 > PURPOSES ONLY. 1t ).3"15REBAR 2"CENTER SECTION 'B-B' io D -oo C* 1 MIN. 'cr_ -c—Ln(T--Y-01 4x4 W4xW4 WWF (LAP wwr 6" ON- TO REBARS} NOTE: Lu V` MIN, NO WAFFLE BOXES WILL BE ALLOWED IN HTE CITY (Typ) RIGHT-OF-WAY OR EASEMENTS UNDER ANY cc 0 10" c CIRCUMSTANCES. ALL STRUCTURES UNDER TRAFFIC SHALL LL 0 BE TRAFFIC BEARING. THIS INCLUDES DRAINAGE 3 CC STRUCTURES IN PARKING S AND DRIVEWAYS. R z ,/-#S REBARS Ca 12' CENTERS (HORIZ. W & VERT.) (USE WITH WITH- a W 9 4' X 4' & LARGER 4' STRUCTURES TYPICAL) La p. I� D "m 2 z SOLID WALL PLAN VIEW m T> 6" 611 IWI 611, 61t v - i -I- .. I -F X co 1. 0 7 -1" MIN. CLR. 0 -n 1 MIN. CLR. 0 4x4 W4xW4 z U .... M $ III - e uj us -4x4 W4xW4- WWF (LAP —) . It, , P - . .�. . 0. . .�, . % , �": WWF 6" ON- WWF (LAP WWF iD CL M 6" ONTO REBARS)6 !� TO REBARS) #6 REBARS 2 6 REBARS 12' S CENTERS (TYP.) N" CENTERTYPICAL) SHEET I Of 0M 77Y 7 OF 2 840.45 2.9, .t: 1 5 SECTION C'. 0 SHEET 1 SECTION 'D-D' 1 SOLID WALL ISOMETRIC VIEW 840,45 CER11FICATION NOTE: CONTRACTOR SHALL PROVIDE CERTIFICATION FROM A LICENSED NORTH CAROLINA STRUCTURAL ENGINEER THAT PRECAST STRUCTURES PROVIDED MEET REQUIREMENTS FOR H2O LOADING GENERAL NOTES: --04 m * THIS PRECAST BOX MAY BE USED FOR THE FOLLOWING _r STANDARDS: 840.01, 840.02, 840.04, 840.05, 840.11, co,5 1-4 $40.12, 840.140 840.15, 840.17, 840.18, 840.19, C) m z 3: --1 840.26, 640.27, 840.28, 840.31, 840.32 AND 840.41. " -q > G) INSTALL PRECAST DRAINAGE STRUCTURES AND PAY FOR IN ACCORDANCE WITH SPECIFICATION SECTION 840. OPENING SHALL BE 'L' OR 'W' + V-O" - co 1­1 0 >_ LOCATED AS REQUIRED < 2 -to cr #4 REBARS 6" CENTERS < t-Im Z. CC3:0 IN 0 LL _J Z #5 BARS ui LL� Ir ��0 @ OPENING < m STEPS �_ " Xc000 3: Z W Z.-O m DO NOT PLACE PRECAST DRAINAGE STRUCTURES SECTION 'C-C' to- F- U I- _O_j G)O" rr 0 UNDER TRAFFIC OR WHERE TRAFFIC WILL BE DETOURED. #6 BAR 0- 40 C Z USE 4000 PSI CONCRETE. 0 OPENING c > 4 [ PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 FOR C:) W = GRADE 60 AND WELDED WIRE FABRIC CONFORMING TO ASTM A185. - - - - - - - -- LIMIT MAXIMUM DEPTH TO TOP OF BOTTOM SLAB FOR WAFFLE WALL STRUCTURE TO 10'-0"; LIMIT SOLID WALL STRUCTURE To 151-011. 'l ' PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH L16 OSHA STANDARD 1926.704. PLAN TOP SLAB WCUT OR FORM OPENINGS FOR PIPE TO PROVIDE cc L'. -, - f m m REQUIRED SIZE AND LOCATION. ORIENT WAFFLE WALL STRUCTURES 5 6 �,-, , '. $ cr_ c*Az $0 THAT PIPES ENTER THROUGH THE 6) z LL m > 0 ­. " (a r, KNOCKOUT/WAFFLE PANELS ONLY. PIPES MAY INTER THROUGH z CORNER CUT DETAIL 6jr OF z W. m -4 co THE CORNERS OF SOLID WALL BOXES IF A MINIMUM OF ISOLID WA F-4 II.. 3: WALL IS PROVIDED ABOVE THE HOLE. . q * 611 6)1 0 0) * ALL ELEMENTS PRECAST TO MEET ASTM 0913. 'Ll OR 'Wf r Ir. z -4 © W z #4 REBARS < o FRAME AND GRATE HEIGHT MAY BE ADJUSTE.'-"""'TH CONCRETE 4 M OR BRICK IN ACCORDANCE WITH STANDARD 840-25. - 1„ CL8 1j, 6" CENTERS co ir m > PROVIDE PRECAST STRUCTURES OVER 4'-0" IN DEPTH WITH #4 REBARS < 7g-. W > if co I ci A . . - - jE < z z M WELDED WIRE FABRIC MAY BE SUBSTITUTED FORREBARAS LONG 11._ I STEPS AS DIRECTED BY THE ENGINEER. 6" CENTERS a: 0 ­11 - - AS THE SAME AREA OF STEEL IS PROVIDED. i�LR co jo _j 0 (A SEAL JOINTS WITH A FLEXIBLE BUTYL RUBE' M w PRECAST RISER PLAN PRECAST RISER DETAIL X z BASE CONFORMING TO FEDERAL SPECIFICATION SS-S-21A, z I(= G) _j AASHTO M-1980 TYPE B - BUTYL RUBBER. W Cris0 -n LIMIT MAXIMUM STRUCTURE SIZE TO INSIDE CLEAR 0 W DIMENSIONS OF 5 x W16:91 1: cc THE OUTSIDE PIPE DIAMETER PLUS 2" OR THE OPENING 1 M REQUIRED FOR FRAME AND GRATE IS THE MINIMUM STRUCTURE 9L SIZE WHICHEVER IS GREATER. 6" 6lt USE MANHOLE FRAME AND COVER AS INDICATED ON THE PLANS. REINFORCE OPENING AS SHOWN ON THIS SHEET, SECTION VIEW SECTION VIEW SHEET 2 Of 2 OPTIONAL JOINT DETAILS SHEET 2 OF 2 840.45 840.45 DROP INLET DETAIL NOT TO SCALE 121 ■ I6111�I�II�II�IIiI It I I - IIIIIIIIIIIIII 1 34 air 41 1/2 23 3/4—. 1 1/2 - _� 6 3/4 I H_ i 4 T 22 24- 29 1/4 1 6 9/16 23 22 /4 24 29 1/2 — -Ir Ad I- VATERIAL-., ASTV-A48 A 30a GRAY moN. 2- F A165L8S APP, VE 3- GRATE VT.-� 210 LDS APP. U U.S. FOUNDRY & WFQ. ODRP. 'zii, mwm, mmoA -- ---- USF 4139 FRAVE & 6429 GRATE 23 3/4 22 2. 4 29 1/4 1 5/16 N_ QM$ I- MATFRIAL: ASTM-A48 CLASS 35B GRAY IRON. 2- FRAME WT: 125 I.BS. APP. 3-- GRAI'E W-1. 115 LBS. APP. DROP INLET FrNI-NIVIE & Gt_xf_I%TE DETAILS NOT TO SCALE O 0 c) 0 0 0 U- z (D z W u Z CD co 4-J A C�\ 0 z 0 (j * o o 1­11 r, u p o z z W U x xu 0 z i: 3: Z IN 00 0 > U) I-- 0 00 LL Q) z 0 0 0 u- z W W :2 0 (o < 6 C) uj uj w 1") Lu Ci 0 z _Ij WCL W 0 < 6 2 � SEAL GAA� 0 oA g, c % - 03 2 3 Ili : % C-6os4 PEE JOB#: 15255,PE