HomeMy WebLinkAboutSW5210702_Plansheet - Misc. Detail_20210708 (10)\007 ___4p7� �07 `007� '1� '1� "�N\ I % \ �SSMH #8 /NV. /N (7) = 280. 05' \ /NV. OUT (9) = 279 85' \ I \ I 1 50' TAR —PAY RIPAR14N BUFFER ,F—PAY RIPAR4N / / 20' BUILDING SETBACK 00l 00l 001 001 001 001 RETAIL WAY (50' PUBLIC R/W) 00l 001 0ol 00l 001 00100l O0l 00l 001 001 0 LOD LOD LOD LOD LOD LOD LOD LOD II 8' D/P WATER #AIN II s o s s II II J72.53 LF OF 8" PVC SAN. MAIN UTILITY LEGEND (NOT TO SCALE) EX/ST/NGNOTE TYPICAL NOTE TEXT PROPOSED NOTE SAN # SANITARY LABEL SAN # eST STORM LABEL T # .S� SANITARY SEWER LATERAL SL UNDERGROUND WATER LINE E UNDERGROUND ELECTRIC LINE E UNDERGROUND GAS LINE OVERHEAD WIRE T UNDERGROUND TELEPHONE LINE T _ UNDERGROUND CABLE LINE G, STORM SEWER zz SANITARY SEWER MAIN S HYDRANT *cf SANITARY MANHOLE II \ _i STORM MANHOLE i WATER METER WATER VALVE • CURB INLET ❑® CLEAN OUT n ELEC. TRANSFORMER ON CONC. PAD TEST PIT GENERAL UTILITY NOTES. 1. ALL MATERIALS & CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH TOWN OF LOUISBURG DESIGN STANDARDS, DETAILS & SPECIFICATIONS. 2. UTILITY SEPARATION REQUIREMENTS: A. A DISTANCE OF 100' SHALL BE MAINTAINED BETWEEN SANITARY SEWER & ANY PRIVATE OR PUBLIC WATER SUPPLY SOURCE SUCH AS AN IMPOUNDED RESERVOIR USED AS A SOURCE OF DRINKING WATER. IF ADEQUATE LATERAL SEPARATION CANNOT BE ACHIEVED, FERROUS SANITARY SEWER PIPE SHALL BE SPECIFIED & INSTALLED TO WATERLINE SPECIFICATIONS. HOWEVER, THE MINIMUM SEPARATION SHALL NOT BE LESS THAN 25' FROM A PRIVATE WELL OR 50' FROM A PUBLIC WELL. B. WHEN INSTALLING WATER &/OR SEWER MAINS, THE HORIZONTAL SEPARATION BETWEEN UTILITIES SHALL BE 10'. IF THIS SEPARATION CANNOT BE MAINTAINED DUE TO EXISTING CONDITIONS, THE VARIATION ALLOWED IS THE WATER MAIN IN A SEPARATE TRENCH WITH THE ELEVATION OF THE WATER MAIN AT LEAST 18" ABOVE THE TOP OF THE SEWER & MUST BE APPROVED BY THE PUBLIC UTILITIES DIRECTOR. ALL DISTANCES ARE MEASURED FROM OUTSIDE DIAMETER TO OUTSIDE DIAMETER. C. WHERE IT IS IMPOSSIBLE TO OBTAIN PROPER SEPARATION, OR ANYTIME A SANITARY SEWER PASSES OVER A WATERMAIN, DIP MATERIALS OR STEEL ENCASEMENT EXTENDED 10' ON EACH SIDE OF CROSSING MUST BE SPECIFIED & INSTALLED TO WATERLINE SPECIFICATIONS. D. 5.0' MINIMUM HORIZONTAL SEPARATION IS REQUIRED BETWEEN ALL SANITARY SEWER & STORM SEWER FACILITIES, UNLESS DIP MATERIAL IS SPECIFIED FOR SANITARY SEWER. E. MAINTAIN 18" MIN. VERTICAL SEPARATION AT ALL WATERMAIN & RCP STORM DRAIN CROSSINGS; MAINTAIN 24" MIN. VERTICAL SEPARATION AT ALL SANITARY SEWER & RCP STORM DRAIN CROSSINGS. WHERE ADEQUATE SEPARATIONS CANNOT BE ACHIEVED, SPECIFY DIP MATERIALS & A CONCRETE CRADLE HAVING 6" MIN. CLEARANCE. F. ALL OTHER UNDERGROUND UTILITIES SHALL CROSS WATER & SEWER FACILITIES WITH 18" MIN. VERTICAL SEPARATION REQUIRED. 3. ANY NECESSARY FIELD REVISIONS ARE SUBJECT TO REVIEW & APPROVAL OF AN AMENDED PLAN &/OR PROFILE BY THE TOWN OF LOUISBURG PUBLIC UTILITIES DEPARTMENT PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL MAINTAIN CONTINUOUS WATER & SEWER SERVICE TO EXISTING RESIDENCES & BUSINESSES THROUGHOUT CONSTRUCTION OF PROJECT. ANY NECESSARY SERVICE INTERRUPTIONS SHALL BE PRECEDED BY A 24 HOUR ADVANCE NOTICE TO THE TOWN OF LOUISBURG PUBLIC UTILITIES DEPARTMENT. 5. 3.0' MINIMUM COVER IS REQUIRED ON ALL WATER MAINS & SEWER FORCEMAINS. 6. IT IS THE DEVELOPER'S RESPONSIBILITY TO ABANDON OR REMOVE EXISTING WATER & SEWER SERVICES NOT BEING USED IN REDEVELOPMENT OF A SITE UNLESS OTHERWISE DIRECTED BY THE TOWN OF LOUISBURG PUBLIC UTILITIES DEPARTMENT. 7. INSTALL 4" SDR21 PVC SEWER SERVICES @ 1.0% MINIMUM GRADE WITH CLEANOUTS LOCATED AT ROW OR EASEMENT LINE & SPACED EVERY 100 LINEAR FEET MAXIMUM. 8. ALL ENVIRONMENTAL PERMITS APPLICABLE TO THE PROJECT MUST BE OBTAINED FROM NCDEQ, USACE &/OR FEMA FOR ANY RIPARIAN BUFFER, WETLAND &/OR FLOODPLAIN IMPACTS (RESPECTIVELY) PRIOR TO CONSTRUCTION. 9. NCDOT / RAILROAD ENCROACHMENT AGREEMENTS ARE REQUIRED FOR ANY UTILITY WORK (INCLUDING MAIN EXTENSIONS & SERVICE TAPS) WITHIN STATE OR RAILROAD ROW PRIOR TO CONSTRUCTION. LEGEND NOTES. 1B PROVIDE ONE (1) 1" CONDUIT EXTENDING FROM MAIN ELECTRICAL PANEL TO MONUMENT SIGN AS INDICATED. ELECTRICAL CONTRACTOR SHALL COORDINATE FINAL ROUTING OF CONDUIT WITH ALL TRADES PRIOR TO INSTALLATION. ELECTRICAL CONTRACTOR SHALL PROVIDE PULLSTRING. ELECTRICAL CONTRACTOR SHALL STUB -UP AND CAP CONDUIT AT GRADE LEVEL FOR MONUMENT SIGN. 2B PROVIDE SERVICE FEEDERS (CONDUCTORS AND CONDUIT) EXTENDING FROM PROPOSED POWER COMPANY TRANSFORMER LOCATION TO NEW ELECTRICAL PANEL. REFER TO MEP PLANS FOR MORE INFORMATION. 3B PROVIDE ONE (1) 4" CONDUIT WITH PULLSTRINGS EXTENDING FROM MECHANICAL ROOM TO UTILITY R/W FOR TELE/DATA CABLING/WIRES. ELECTRICAL CONTRACTOR SHALL STUB -UP AND CAP CONDUIT 2' ABOVE GRADE WITHIN BUILDING AND ALONG UTILITY R/W. ELECTRICAL SHALL COORDINATE FINAL ROUTING WITH ALL TRADES AND UTILITY COMPANY PRIOR TO INSTALLATION. 4B GAS SERVICE WITH METER STUBBED WITH 5'-0" OF MECHANICAL ROOM. REFER TO MEP PLAN FOR INFORMATION. CONTRACTOR SHALL COORDINATE WITH ALL TRADES AND UTILITY COMPANY PRIOR TO INSTALLATION. 5B 1-1/4" DOMESTIC WATER SERVICE WITH METER STUBBED WIHTIN 5'-0" OF STORAGE/JANITOR'S CLOSET. CONTRACTOR SHALL COORDINATE WITH ALL TRADES AND UTILITY COMPANY PRIOR TO INSTALLATION. 0 Z W w z w �W w U Z Zz W w02WUgUa (�ZwWW>W c9!zo�cn H w Q= W z J>z0WU)0 (nQZQ O Q Q 0- z� UZ�U~20- Q �zcn0-z > J U W U) REVISIONS K wo o - �0 iN zz so o �w om x zg DRAWN BY REV I DATE COMMENT Know what's below. Call before you dig. ALWAYS CALL 811 It's fast. It's free. It's the law. IFOR REVIEW I PURPOSES ONLY THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: NCR211056 DRAWN BY: SJK CHECKED BY: CEY DATE: 7/2/2021 CAD I.D.: UTIL-0 PROJECT: SITE IMPROVEMENT PLANS FOR GFD MANAGEMENT INC.I LOUISBURG ANNEX LOUISBURG PLAZA RETAIL WAY FRANKLIN COUNTY LOUISBURG, NC 27549 BOHLER# BOHLER ENGINEERING NC, PLLC NCBELS P-1132 4130 PARKLAKE AVENUE, SUITE 130 RALEIGH, NC 27612 Phone: (919)578-9000 NC@BohlerEng.com OFESS /0�iaa ( %' SEAL - 485 NG 0 221 ooj��/ SHEET TITLE: UTILITY PLAN SHEET NUMBER: C-501 N N 0 ORG. DATE - 6/23/2021