HomeMy WebLinkAboutSW6210204_Plan (SCM Detail)_20210422(H)(W)4'-6"(8'-0" [2438])CONTECH STORMFILTER DESIGN NOTES (BASIS OF DESIGN) 3'-3" [991] INLETINLET BAY FRAME AND COVER LOCATION TRANSFER HOLE AND COVER FILTRATION BAY · ALL PARTS AND INTERNAL ASSEMBLY PROVIDED BY CONTECH UNLESS NOTED OTHERWISE CARTRIDGE SIZE (in. [mm]) RECOMMENDED HYDRAULIC DROP (H) (ft. [mm]) HEIGHT OF WEIR (W) (ft. [mm]) SPECIFIC FLOW RATE (gpm/sf [L/s/m2]) CARTRIDGE FLOW RATE (gpm [L/s]) 2 [1.36] 18 [457] 2.3 [701] 2.25 [686] 1.67* [1.13]* * 1.67 gpm/sf [1.13 L/s/m2] SPECIFIC FLOW RATE IS APPROVED WITH PHOSPHOSORB® (PSORB) MEDIA ONLY ALTERNATE PIPE LOCATION OUTLET BAY OUTLET ACCESS HATCH LOCATION PLAN (11'-0" [3353]) ® www.ContechES.com FRAME AND GRATE (24" SQUARE) (NOT TO SCALE) 1 [0.68] 15 [0.95] 12.53 [0.79] 7.5 [0.47] ACCESS HATCH (36" x 72") FRAME AND COVER CAST-IN (FLUSH MOUNTED) SEPARATION WALL ACCESS HATCH CAST-IN (FLUSH MOUNTED) FRAME AND COVER (30" ROUND) (NOT TO SCALE) PERFORMANCE SPECIFICATION INLET PIPE WEIR WALL FILTER CARTRIDGES SHALL BE MEDIA-FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL BE 7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 38 SECONDS. SPECIFIC FLOW RATE SHALL BE 2 GPM/SF (MAXIMUM). SPECIFIC FLOW RATE IS THE MEASURE OF THE FLOW (GPM) DIVIDED BY THE MEDIA SURFACE CONTACT AREA (SF). MEDIA VOLUMETRIC FLOW RATE SHALL BE 6 GPM/CF OF MEDIA (MAXIMUM). GENERAL NOTES 1. CONTECH (OR APPROVED EQUAL) TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. 2. DIMENSIONS MARKED WITH ( ) ARE REFERENCE DIMENSIONS. 3. FOR FABRICATION DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR CONTECH REPRESENTATIVE. www.ContechES.com 4. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS DRAWING. CONTRACTOR TO CONFIRM STRUCTURE MEETS REQUIREMENTS OF PROJECT. 5. STRUCTURE SHALL MEET AASHTO HS-20 LOAD RATING, ASSUMING EARTH COVER OF 0'-0", AND GROUNDWATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL MEET AASHTO M306 AND BE CAST WITH THE CONTECH LOGO. OUTLET PIPE ELEVATION FLOW KIT INSTALLATION NOTES A. ANY SUB-BASE, BACKFILL DEPTH, AND/OR ANTI-FLOTATION PROVISIONS ARE SITE-SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD. B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE. C. CONTRACTOR TO ASSEMBLE STRUCTURE. D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT PIPES. MATCH OUTLET PIPE INVERT WITH OUTLET BAY FLOOR. E. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION-RELATED EROSION RUNOFF. F. CONTRACTOR TO REMOVE THE TRANSFER HOLE COVER WHEN THE SYSTEM IS BROUGHT ONLINE. (NOT TO SCALE) 92'-0" 41'-0" 30"Ø RISER E1 35'-0" 15"Ø STUB E2 TO SFPD INLET 8'-0" 30"Ø RISER C1, D1 36"Ø BULKHEAD H1 C K A K K D K B K K INV. IN = 263.00' E K G K BAND, TYPICAL SEE DETAIL SHEET P3 H H K K K K F K K K H H J *MINIMUM REQUIRED RIM OVER SYSTEM IS 267.00' TO MAINTAIN 1' OF COVER H 15"Ø STUB J2 TO UPSTREAM CB K K K K H H 30"Ø RISER C1 30"Ø RISER D1 30"Ø RISER E1 30"Ø RISER F1 30"Ø RISER G1 267.00 267.00 267.00 267.00 267.00 RISER INFORMATION PIECE RIM ELEV. 18'-0" 30"Ø RISERS F1, G1 12"Ø STUB E2 24"Ø STUB E3 15"Ø STUB J2 263.00 263.00 263.00 263.00 263.00 263.00 STUB INFORMATION PIECE STUB INVERT SYSTEM INVERT SYSTEM INVERT 263.00 263.00 263.00 263.00 263.00 3.25' WQV WEIR @265.25' INV. OUT = 262.50' · PIPE STORAGE = 5,253 CF · MAINLINE PIPE GAGE = 14 · WALL TYPE = SOLID · DIAMETER = 36" · FINISH = ALT2 · CORRUGATION = 2 2/3x1/2 ASSEMBLY SCALE: 1" = 10' PIPE STORAGE: 5,253 CF LOADING: H20 PIPE INV. = 263.00'± NOTES · ALL RISER AND STUB DIMENSIONS ARE TO CENTERLINE. · ALL ELEVATIONS, DIMENSIONS, AND LOCATIONS OF RISERS AND INLETS, SHALL BE VERIFIED BY THE ENGINEER OF RECORD (EOR) PRIOR TO RELEASING FOR FABRICATION. · ALL FITTINGS AND REINFORCEMENT COMPLY WITH ASTM A998. · ALL RISERS AND STUBS ARE 2-2/3" x 1/2" NOTED. · RISERS TO BE FIELD TRIMMED TO GRADE AS REQUIRED, BY CONTRACTOR. · QUANTITY OF PIPE SHOWN DOES NOT PROVIDE EXTRA PIPE FOR CONNECTING THE SYSTEM TO EXISTING PIPE OR DRAINAGE STRUCTURES. OUR SYSTEM AS DETAILED PROVIDES NOMINAL INLET AND/OR OUTLET PIPE STUB FOR CONNECTION TO EXISTING DRAINAGE FACILITIES. IF ADDITIONAL PIPE IS NEEDED IT IS THE RESPONSIBILITY OF THE CONTRACTOR. · ALL ACCESS CASTINGS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE NOT SUPPLIED BY CONTECH. CORRUGATION AND 16 GAGE UNLESS OTHERWISE31'-0"5'-0"1'-0"TYP.36" UNDERGROUND DETENTION SYSTEM1 N.T.S.8' X 11' FILTER UNIT (BASIS OF DESIGN)2 N.T.S. 20 MIL PE TRENCH CONDITION IMPERMEABLE LINER OVER TOP OF PIPE (IF REQUIRED) 12" 36" TYP.TYP. LIMITS OF REQUIRED BACKFILL 6a 15" SEE TYPICAL BACKFILL DETAIL NOTES 6 TYPICAL SECTION VIEW NOT TO SCALE BEDDING FOUNDATION 5b IN SITU 5a 4 DIAMETER 3 5 2 INITIAL FILL ENVELOPE 1 1a BACKFILL REQUIREMENTS FOLLOW THE GUIDELINES OF AASHTO LRFD BRIDGE DESIGN (SEC 12) AND CONSTRUCTION (SEC 26) 1 MINIMUM TRENCH WIDTH MUST ALLOW ROOM FOR PROPER COMPACTION OF HAUNCH MATERIALS UNDER THE PIPE. THE MINIMUM TRENCH WIDTH (12.6.6.1): PIPE ≤ 12": D + 16" PIPE > 12": 1.5D + 12" 1a MINIMUM EMBANKMENT WIDTH (IN FEET) FOR INITIAL FILL ENVELOPE (12.6.6.2): PIPE < 24": 3.0D PIPE 24" - 144": D + 4'0" PIPE > 144": D + 10'0" 2'-6"2 THE FOUNDATION UNDER THE PIPE AND SIDE BACKFILL SHALL BE ADEQUATE TO SUPPORT THE LOADS ACTING UPON IT (26.5.2). 3 BEDDING MATERIAL SHALL BE A RELATIVELY LOOSE MATERIAL THAT IS ROUGHLY SHAPED TO FIT THE BOTTOM OF THE PIPE FROM SPRINGLINE OF PPE TO 4"-6" BELOW BOTTOM OF PIPE.PIPE Ø PLAN 2'-6" 4 CORRUGATED STEEL PIPE (CSP / HEL-COR). 5 HAUNCH ZONE MATERIAL SHALL BE HAND SHOVELED OR SHOVEL SLICED INTO PLACE TO ALLOW FOR PROPER COMPACTION (26.5.4). 5a GEOTEXTILE SHALL BE USED IF REQUIRED BY ENGINEER TO PREVENT SOIL MIGRATION INTO VARYING SOIL TYPES. 5b BACKFILL PLACED ABOVE SPRINGLINE TO MEET AASHTO 145, A-1, A-2 OR A-3 CLASSIFICATION, OR APPROVED EQUAL, COMPACTED TO 90% STANDARD PROCTOR (T 99). MAXIMUM PARTICLE SIZE NOT TO EXCEED 3" (12.4.1.2). ALL LIFTS PLACED IN A CONTROLLED MANNER. IT IS RECOMMENDED THAT LIFTS NOT EXCEED AN 8" UNCOMPACTED LIFT HEIGHT TO PREVENT UNEVEN LOADING, AND THE LESSER OF 1/3 THE DIAMETER OR 24" AS THE MAXIMUM DIFFERENTIAL SIDE-TO-SIDE (26.5.4). 6 INITIAL BACKFILL ABOVE PIPE MAY INCLUDE ROAD BASE MATERIAL (AND RIGID PAVEMENT IF APPLICABLE). SEE TABLE ABOVE. FRONT 48"Ø to 90"Ø FITTING REINFORCEMENT MAY BE REQUIRED BASED ON HEIGHT OF COVER AND LIVE LOAD CONDITION TYPICAL MANWAY DETAIL NOT TO SCALE 6a TOTAL HEIGHT OF COMPACTED COVER FOR CONVENTIONAL HIGHWAY LOADS IS MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TOP OF RIGID PAVEMENT (12.6.6.3). 7 FINAL BACKFILL MATERIAL SELECTION AND COMPACTION REQUIREMENTS SHALL FOLLOW THE PROJECT PLANS AND SPECIFICATIONS PER THE ENGINEER OF RECORD (26.5.4.1). NOTES: · FOR MULTIPLE BARREL INSTALLATIONS THE RECOMMENDED STANDARD SPACING BETWEEN PARALLEL PIPE RUNS SHALL BE PIPE DIA./2 BUT NO LESS THAN 12", OR 36" FOR PIPE DIAMETERS 72" AND LARGER. CONTACT YOUR CONTECH REPRESENTATIVE FOR NONSTANDARD SPACING (TABLE C12.6.7-1). 6"-10" 12"-48" 54"-96" 102"-144" MIN. COVER 12" 12" 12" D/8 CORR. PROFILE 1 1/2" x 1/4" 2 2/3" x 1/2" 3" x 1", 5" x 1" 3" x 1", 5" x 1" 7 INITIAL BACKFILL FINAL BACKFILL EMBANKMENT CONDITION PIPE ØPIPE Ø1'-0" MIN.PIPE EMBEDMENTDIAMETER (D)TYPICAL BACKFILL DETAIL3 N.T.S. NOTE: IF SALTING AGENTS FOR SNOW AND ICE REMOVAL ARE USED ON OR NEAR THE SURROUNDING ENVIRONMENT OVER A PERIOD OF TIME. PLEASE REFER TO THE GEOMEMBRANE LINER IS INTENDED TO HELP PROTECT THE SYSTEM FROM THE POTENTIAL ADVERSE EFFECTS THAT MAY RESULT FROM A CHANGE IN THE PROJECT, A GEOMEMBRANE BARRIER IS RECOMMENDED WITH THE SYSTEM. THE CORRUGATED METAL PIPE DETENTION DESIGN GUIDE FOR ADDITIONAL INFORMATION. A TEMPORARY COVER FOR CONSTRUCTION LOADS HEIGHT OF COVER FINISHED GRADE CMP PROTECTION SLAB RIM/FINISHED GRADE 36"Ø MAX., HS-25 ACCESS CASTING WITH GRADE RINGS AS REQUIRED, TO BE PROVIDED AND INSTALLED BY CONTRACTOR. MAY BE TOP MOUNTED (AS SHOWN) OR RECESSED. VARIES 24" 30" CONSTRUCTION LOADS FOR TEMPORARY CONSTRUCTION VEHICLE LOADS, AN EXTRA AMOUNT OF COMPACTED COVER MAY BE REQUIRED OVER THE TOP OF THE PIPE. THE HEIGHT-OF-COVER SHALL MEET THE MINIMUM REQUIREMENTS SHOWN IN THE TABLE BELOW. THE USE OF HEAVY CONSTRUCTION EQUIPMENT NECESSITATES GREATER PROTECTION FOR THE PIPE THAN FINISHED GRADE COVER MINIMUMS FOR NORMAL HIGHWAY TRAFFIC. PIPE SPAN, INCHES 18-50 12-42 48-72 78-120 126-144 2.0 3.0 3.0 3.5 AXLE LOADS (kips) 50-75 75-110 MINIMUM COVER (FT) 2.5 3.0 3.5 4.0 3.0 3.5 4.0 4.5 110-150 3.0 4.0 4.0 4.5 *MINIMUM COVER MAY VARY, DEPENDING ON LOCAL CONDITIONS. THE CONTRACTOR MUST PROVIDE THE ADDITIONAL COVER REQUIRED TO AVOID DAMAGE TO THE PIPE. MINIMUM COVER IS MEASURED FROM THE TOP OF THE PIPE TO THE TOP OF THE MAINTAINED CONSTRUCTION ROADWAY SURFACE. CONSTRUCTION LOADING DIAGRAM NOT TO SCALE OPENING IN PROTECTION SLAB FOR ACCESS SPECIFICATION FOR CORRUGATED STEEL PIPE-ALUMINIZED TYPE 2 STEEL SCOPE THIS SPECIFICATION COVERS THE MANUFACTURE AND INSTALLATION OF THE CORRUGATED STEEL PIPE (CSP) DETAILED IN THE PROJECT PLANS. MATERIAL THE ALUMINIZED TYPE 2 STEEL COILS SHALL CONFORM TO THE APPLICABLE REQUIREMENTS OF AASHTO M274 OR ASTM A929. PIPE THE CSP SHALL BE MANUFACTURED IN ACCORDANCE WITH THE APPLICABLE REQUIREMENTS OF AASHTO M36 OR ASTM A760. THE PIPE SIZES, GAGES AND CORRUGATIONS SHALL BE AS SHOWN ON THE PROJECT PLANS. ALL FABRICATION OF THE PRODUCT SHALL OCCUR WITHIN THE UNITED STATES. MATERIAL SPECIFICATION NOT TO SCALE SHALL BE IN ACCORDANCE WITH AASHTO STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES, SECTION 26, DIVISION II OR ASTM A798 AND IN CONFORMANCE WITH THE PROJECT PLANS AND SPECIFICATIONS. IF THERE ARE ANY INCONSISTENCIES OR CONFLICTS THE CONTRACTOR SHOULD DISCUSS AND RESOLVE WITH THE SITE ENGINEER. IT IS ALWAYS THE RESPONSIBILITY OF THE CONTRACTOR TO FOLLOW OSHA GUIDELINES FOR SAFE PRACTICES. NOTES: 1. DESIGN IN ACCORDANCE WITH AASHTO, 17th EDITION AND ACI 350. 2. DESIGN LOAD HS25. 3. EARTH COVER = 1' MAX. 4. CONCRETE STRENGTH = 4,000 psi 5. REINFORCING STEEL = ASTM A615, GRADE 60. 6. PROVIDE ADDITIONAL REINFORCING AROUND OPENINGS EQUAL TO THE BARS INTERRUPTED, HALF EACH SIDE. ADDITIONAL BARS TO BE IN THE SAME PLANE. 7. TRIM OPENING WITH DIAGONAL #4 BARS, EXTEND BARS A MINIMUM OF 12" BEYOND OPENING, BEND BARS AS REQUIRED TO MAINTAIN BAR COVER. 8. PROTECTION SLAB AND ALL MATERIALS TO BE PROVIDED AND INSTALLED BY CONTRACTOR. 9. DETAIL DESIGN BY DELTA ENGINEERS, ARCHITECTS AND LAND SURVEYORS, ENDWELL, NY. INTERRUPTED BAR REPLACEMENT, SEE NOTE 6. HANDLING AND ASSEMBLY SHALL BE IN ACCORDANCE WITH RECOMMENDATIONS OF THE NATIONAL CORRUGATED STEEL PIPE ASSOCIATION (NCSPA) INSTALLATION STANDARD REINFORCING, SEE TABLE ROUND OPTION PLAN VIEW STANDARD REINFORCING, SEE TABLE ØB SQUARE OPTION PLAN VIEW Ø CMP RISER 36" 42" ØB SECTION VIEW A B #4 DIAGONAL TRIM BAR (TYP. 4 PLACES), SEE NOTE 7. #4 DIAGONAL TRIM BAR (TYP. 4 PLACES), SEE NOTE 7. 2" COVER (TYP) 11" TYP. 48" 4'Ø 4'x4' 4'-6"Ø 4'-6" x 4'-6" 5'Ø 5' x 5' 5'-6"Ø 5'-6" x 5'-6" 6'Ø 6' x 6' 26" 32" 38" 44" 50" ** ASSUMED SOIL BEARING CAPACITY A #5 @ 10" OCEW #5 @ 10" OCEW #5 @ 10" OCEW #5 @ 9" OCEW #5 @ 9" OCEW #5 @ 8" OCEW #5 @ 8" OCEW #5 @ 8" OCEW #5 @ 7" OCEW #5 @ 7" OCEW 2,540 1,900 2,260 1,670 2,060 1,500 1,490 1,370 1,210 1,270 REINFORCING TABLE Ø CMP RISER A B Ø REINFORCING **BEARING PRESSURE (PSF) OPENING IN PROTECTION SLAB FOR ACESS INTERRUPTED BAR REPLACEMENT, SEE NOTE 6. MANHOLE CAP DETAIL NOT TO SCALE1'-0"8"1" GAP (TYP. ALLSIDES)2" COVERTYP.A2 " COVER (TYP . )2" COV E R (TYP.)2" COV E R (TYP) MANHOLE CAP DETAIL, CONSTRUCTION LOADING DIAGRAM & MATERIAL SPECIFICATION 4 N.T.S. · A 8' x 11' [2438 x 3353] PEAK DIVERSION STYLE STORMFILTER IS SHOWN WITH THE MAXIMUM NUMBER OF CARTRIDGES (18) AND IS AVAILABLE IN A LEFT INLET (AS SHOWN) OR A RIGHT INLET CONFIGURATION · STORMFILTER TREATMENT CAPACITY VARIES BY CARTRIDGE COUNT AND LOCALLY APPROVED SURFACE AREA SPECIFIC FLOW RATE. PEAK CONVEYANCE CAPACITY TO BE DETERMINED BY ENGINEER OF RECORD (16) CONTECH STORMFILTER CARTRIDGES (BASIS OF DESIGN) CONTECH STORMFILTER CARTRIDGES (BASIS OF DESIGN ) CONTECH SFPD0811-S W/ 16-18'' PERLITE CARTRIDGES (BASIS OF DESIGN) GASKET MATERIAL SUFFICIENT TO PREVENT SLAB FROM BEARING ON RISER. PIPE REQUIREMENTS: JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICEN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R 0 3 3 6 1 2N O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R S E A LN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RF R A N C I S S L I N S K Y, I I I2020-DEC-01 NCNG RAEFORD POV & MOV EXPANSION305 TEAL DRIVE RAEFORD, NORTH CAROLINA, 28376, NCNG# 3720140172 / SCO# 18-19694-01A43358 J. LEWIS F. SLINSKY F. SLINSKY PRELIMINARY PLANS FOR REVIEW ONLY DO NOT USE FOR CONSTRUCTION C5.6 SITE DETAILS