HomeMy WebLinkAboutSW1210602_Plansheet - SCM Detail_20210630DocuSign Envelope ID: 61796BC1 -4762-4278-AF1 1-747CBB7384D7
0
r-i
N
N
0
Ln
N
as
3
0
0
N
0
M
U
U
c
U
'o
L
Q
w
fA
D
LL
I�
PROPOSED
FOREBAY #1
PROPOSED
EMERGENCY
SPILLWAY
PROPOSED
CI #17
ROPOSED 212C ROPOSED
PROPOSED CI #16 PROPOSED CI #15
FOREBAY #2 \ FOREBAY #3
ROPOSED
2120 CI #14 PROPOSED
FOREBAY #4 -
2110
\ 4 2100 N
-� --- --- T-� 18 LF -� T-� 3-- -- ---- --
=,,... 119 LF Y � - - _
10 LF � _10-LF 128 LF
99 LF-� 65 LF _ I -� - -� - - _ _ _ �- } _ - - - -
156 LF
♦ ♦ ., \ - 144 LF _� - - 10 LF 171 LF T
123 LF
10 LFI � 4 322 LF 43---�----
�� - - �, _ -y- - _ �_ _�,_
♦♦ 96 LF y 10 LF! 313 LF' �___-----�-• �/
• -� - 66 LF 10, LF 304 LF 4 - - _� ��
36 LF 10 LF 25 LF _�_ _� >\ >\296 LF---------�-� / o
DO 10 LF _�_ - 261 LF _ 3 x
PROPERTY__ �___�_------
BOUNDARY 3 LF � 252 LF - -�- -�-
> >
10' BERM--------------3- ----��
PROPOSED 4" PVC/SCH 40 +2100' 2100 _
CLEANOUT (TYP.) (19 TOTAL)
PROPOSED OTCB #9
(TO BE CONVERTED TO OCS) /
♦ ♦PROPOSED 4" SLOTTED PVC/SCH 40
PROPOSED/(
JB #6 + + + 4444 UNDERDRAIN (TYP.) (2,769 LF TOTAL)
�44
PROPOSED 9" d50 STONE
RIP RAP EXTENDED TO -
ELEV. 2098'
PROPOSED
CI #13.
XISTING WETLAND
•, (TYP.) (PER CEC)
PROPOSED STORM DRAIN ROPOSED RETAINING
DISCHARGE LINE JB PROPOSED ♦ WALL (TYP.)
PROPOSED OUTLET #1
PROPOSED LEVEL
SPREADER #1
CAPPED CLEAN OUT PIPE
TOP ELEV. = "B"
12" HIGH RIP -RAP ENERGY & VELOCITY (SEE BIO-CELL PLAN FOR LOCATIONS)
DISSIPATER WITH FILTER STONE WATER QUALITY
TOP ELEV. = "B" PONDING ELEV. = "B"
FILTER BLANKET TOP OF MULCH CELL
(BOTTOM OF FINISHED
RIP RAP OUTLET PROTECTION CELL) ELEV = "C"
ENERGY DISSIPATING DEVICE 12" WATE
HDPE FROM SITE (9" RIP RAP) QUALITY
INV. ELEV. _ "C" 1299 PONDING
S
......... 0............................................................................
1891'-
............................................
36 MIN. LAYER OF
•
Al Ay v > L L �. L A 1 2 L L .� L
MEDIA MIX
THE MEDIA SHOULD BE COMPOSED OF A
HOMOGENOUS MIX OF THE FOLLOWING:
a. 75-85% MEDIUM TO COURSE WASHED
SAND
b. 8-10% FINES (SILT AND CLAY); AND
c. 5-10% ORGANIC MATTER (SUCH AS PINE
BARK FINES)
MINIMUM MEDIA DEPTH
ALL CELLS WITH TREES AND SHRUBS:
36 INCHES
CELLS WITHOUT TREES AND SHRUBS:
WITH NO IWS: 24 INCHES
WITH IWS: 30 INCHES
MEDIA P-INDEX
LESS THAN 30 IN NSW WATERS
LESS THAN 50 ELSEWHERE
MEDIA MAINTENANCE
MAINTAIN MEDIA SUCH THAT INFILTRATION
RATE IS AT LEAST 1 IN/HR
CONSTRUCTION SEQUENCE:
1.) DO NOT ALLOW FLOW INTO 810-RETENTION CELL UNTIL SITE
IS STABILIZED. (PAVED / GRASS)
2.) CLEAN OUT CELL IF USED AS A SEDIMENT BASIN DURING
CONSTRUCTION.
3.) INSTALL 8" LAYER OF STONE, UNDERDRAINS.
4.) INSTALL FILTER FABRIC, 4" WASHED SAND AND SOIL MEDIA.
5.) INSTALL 4- LAYER OF TRIPLE SHREDDED HARDWOOD MULCH
IN ENTIRE CELL.
/. • PROPOSED STORMWATER
1310-RETENTION CELL '$A'$
SCALE 1 " = 40'
10yr STORM DETENTION PONDING
ELEV. = "G"
-9" OPENING
(INSTALL TRASH RACK/SCREEN
ON OPENINGS) ELEV. = "A"
TOP OF OCS #9 (OVERFLOW
STRUCTURE) W/ MANHOLE
RING AND LID PRECAST
FLUSH INTO TOP
BERM
TOP ELEV. _ "F"
10' EMERGENCY SPILLWAY
ELEV. _ "1"
III
_.._.._.._.._.._.._.._.._. III III III III III
................ III III III III III III III III III
�II� IIIIII IIII
INV. ELEV.= "E$$ PROPOSED 24" HDPE
(WTJ) STORM DRAIN TO JB
LINE 0 13.16%
IIIII III IIIII III IIIIII III IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
i�
INVERT OF OTCB 1711 III III III III III III III III III
-(INTERIOR OF BOX)
ELEV. _ "H"
it 24" I�-
" TO 12" BELOW
)ISCHARGE
9" d50 STONE (RIP RAP)
RIP RAP ENERGY & VELOCITY
DISSIPATER SECTION
NOT TO SCALE
BIO-RETENTION CELL TABLE
CELL #
ELEV. "A"
ELEV. "B"
ELEV. "C"
ELEV. "D"
ELEV. "E"
ELEV. "F"
ELEV. "G"
ELEV. "H"
ELEV. "I„
# OF
CLEANOUTS
Wq VOLUME
REQUIRED
Wq VOLUME
PROVIDED
A
2098.00
2098.00
2097.00
2096.00
2095.16
2100.00
2098.36
2093.00
2099.00
19
31,005 CF
42,730 CF
16'
PROPOSED OUTLET #8
12" HIGH RIP RAP
ENERGY &
VELOCITY W/
FILTER STONE
24' \
,(TOP OF WEIR)
PROPOSED FOREBAY #1
SCALE 1 " = 20'
PROPOSED 9" d50 STONE PROPOSED
RIP RAP EXTENDED TO �� /OUTLET #5
ELEV. 2098'_34' _ _ _ \
12" HIGH RIP RAP
ENERGY &
VELOCITY W/
FILTER STONE
PROPOSED FOREBAY #3
SCALE 1 " = 20'
AS NOTED
ON FOREBAY DETAIL
9" RIP RAP (SEE RIP RAP III,,FIIIi1I�IIi1I�IIi1I�,i1I-
ENERGY & VELOCITY DISSIPATER
SECTION FOR ADDITIONAL DETAILS)
BIO-RETENTION CELL FOREBAY WEIR SECTION
N.T.S.
9" RIP RAP (SEE I
ENERGY & VELOCITY DISSIPATER
SECTION FOR ADDITIONAL DETAILS)
BIO-RETENTION CELL EMERGENCY SPILLWAY SECTION
PROPOSED 9" d50 STONE
RIP RAP EXTENDED TO
ELEV. 2098'
29'5' PROPOSED
OUTLET #7
PROPOSED FOREBAY #2
SCALE 1" = 20'
PROPOSED 9" d50 STONE
RIP RAP EXTENDED TO
ELEV. 2098'
R711 UPI
�1►
•
i
PROPOSED FOREBAY #4
SCALE 1" = 20'
N.T.S.
NOTES:
1. OVERFLOW STRUCTURE SHALL HAVE STANDARD STEPS 16" ON CENTER PRECAST INTO BOX DIRECTLY BELOW MANHOLE ACCESS AND
NOT LOCATED ON SIDE OF BOX THAT HAS AN ORIFICE OR THE OUTLET PIPE.
2.) IN -SITU SOIL MUST NOT BE COMPACTED BY EQUIPMENT.
3.) CELL BOTTOM SHOULD BE SCARIFIED PRIOR TO CELL MATERIAL INSTALLATION TO PROMOTE INFILTRATION.
4.) THE MAXIMUM SIDE SLOPES FOR THE INSIDE OF THE BIO-RETENTION CELL SHALL BE 3: 1. (ELEVATION "F" TO ELEVATION "C")
5.) BIO-RETECTION CELL SHALL BE MULCHED AND PLANTED W/ TREES AND SHRUBS (SEE LANDSCAPING PLAN FOR PLANTINGS).
6.) HDPE PIPING LEAVING OCS SHALL HAVE WATER TIGHT JOINTS.
7.) OCS #9 SHALL BE A MIN. OF 5'x5' PRECAST CONCRETE BOX. KNOCK OUT PANELS (WAFFER BOX) SHALL NOT BE ACCEPTABLE. A
MANHOLE RING AND LID SHALL BE PRECAST FLUSH INTO TOP OF LID.
8.) SOIL MEDIA SHALL EXTEND BENEATH THE ENERGY DISSIPATING DEVICE (FOREBAY) INSIDE BIO-CELL.
9.) TRASH RACK SHALL EXTEND FROM INVERT OF OCS OPENING WEIR TO INVERT OF TOP. TRASH RACK SHALL NOT HAVE ANY
OPENINGS GREATER THAN 54" IN ANY DIRECTION AND SHALL BE MADE OUT OF A NON -CORROSIVE METAL MATERIAL W/A MIN j"0
(REBAR IS NOT ACCEPTABLE).
10.) THE BIO-RETENTION CELL MEDIA SHALL BE MAINTAINED IN A MANNER THAT RESULTS IN A DRAWDOWN OF AT LEAST ONE INCH PER
HOUR AT THE PLANTING SURFACE.
11.) IMPERMEABLE LINER SHALL BE EXTENDED TO ELEVATION "C" IN THE 810-RETENTION CELLS.
•
• •
ig
• : • • • ----=ri
6" #57 STONE -
12" WIDE J
SECTION "A"VIEW CURB FOOTER
NOT TO SCALE
FLOW
_ PATH
11= 8' _7�
12„
12" LAYER OF 12" STONE
INV. OF TOP OF STONE _
, _ 114' j
IN 20 INVERTOFCHANNEL I III -I I II M1 -
200 Ib TENSILE
STRENGTH FILTER FABRIC
SECTION "B" VIEW 12" WIDE
NOT TO SCALE CURB FOOTER
12" LAYER OF 9" STONE TOP OF CURB
(3 FT WIDE) ELEV. 2104.0'
i-I -1 1 1-- 18
I
a..
- 3 FT. WIDE STRIP 12
OF FILTER FABRIC
CONCRETE DETAIL
NCDOT CURB NOT TO SCALE
STD. 846.01
8" X 18" W/ FOOTER
12" LAYER OF
9" STONE
(3 FT WIDE)
- 3 FT. WIDE STRIP
OF FILTER FABRIC
NCDOT CURB
STD. 846.01
8- X 18" W/ FOOTER
NOTES:
1.) BOTTOM WIDTH SHALL BE 24" W/ 3:1 SIDE SLOPES.
2.) 92 LF LEVEL SPREADER LENGTH.
3.) EXTEND CONCRETE CURB LEVEL SPREADER AROUND END FOR
10' (LENGTH NOT INCLUDED IN NOTE #2).
4.) EXTEND CONCRETE CURB UP AND AROUND OUTLET #1 AS TO
DIRECT FLOW INTO LEVEL SPREADER AND OVER CONCRETE CURB
PRIOR TO BYPASSING AROUND CONNECTION TO FES.
NCDOT CURB
STD. 846.01
8" X 18" W/ FOOTER
NOT TO SCALE
PROPOSED LEVEL SPREADER #1 DETAIL
NOT TO SCALE
PIPE
END SECTION
WGLA ENGINEERING, PLLC
724 5th AVENUE WEST
HENDERSONVILLE, NC 28739
(828) 687-7177
WGLA.COM
NC LICENSE P-1342
SunCap
PROPERTY GROUP"
Suncap
Warehouse
Town of Mills River
Henderson County
North Carolina
dNt�AS A�I. �jlklt,
- 07CO3 F7 b148D... °o -
o 4990 0 =
°�°off
°,ciN°°°�°�J
//�/AM ?' 5/2021
�1111110
REVISIONS
DATE
DESCRIPTION
•
V
Know what's below.
Call before you dig.
PROJECT NUMBER: 20176
DATE: 4/21
DRAWN BY: KHC
CHECKED BY: WRB
Bio-Retention
Cell "A"
C-302
SCALE: As -Noted -On -Sheet