Loading...
HomeMy WebLinkAboutSW6210506_Design Calculations Pond 2_20210528DESIGN REQUIREMIENTS: A. Contain the I inch storm Drainage Area, (DA) - 2.24 acres Intensity, (1) - 0.13 inches/hr Composite Runoff Coefficient, (C) 0.30 Maximum Release Rate, (Qj) => 0.09 CIS Drainage Area, (DA) - 2.24 acres Intensity, (1) - 0.13 inches/hr Composite Runoff Coefficient, (C) 0.58 Peak Release Rate, (Qj) - 0. 17 efs Contour Contour Iner. Accum. Stage Elev. Area Storage Storage (S) (Z) 00 (sf) (cf) (cf) 00 In (S) In (Z) Z est 289.5 - - - - - 290.0 3,685 921 921 0.50 6.83 -0.69 0.48 290.5 4,177 1,966 2,887 1.00 ........................ 7.97 ........................... 0.00 1.04 291.0 4,691 2,217 5,104 1.50 8.54 0.41 1.54 291.5 5,226 2,479 7,583 2.00 8.93 0.69 2.02 292.0 5,782 2,752 10,335 2.50 9.24 0.92 2.49 292.5 6,354 3,034 13,369 3.00 9.50 1.10 2.97 293.0 6,940 3,324 16,693 3.50 9.72 1.25 3.46 293.5 7,540 3,620 20,313 4.00 9.92 1.39 3.95 - - fifififififififi fifififififififi -289.50 #NUM! #NUM! #NUM! Regression Output: b- 1.47 (X Variable Coeff) Ks- 2,708 (e Y-iriter-pt ) Stage - Storage Equation is of the form: S - (Ks)(Z) b printed: 5/20/2021 8 51 AM Page 1 of 3 Barrel Number of Barrels — Dia. of Barrel — Area of Barrel, (Ab) — Pipe Length, (L) — Friction Coeff., (Kp) — Inv. of Barrel — Riser Elev. of Riser Crest Rectangul Length Weir— 36 inches Total Weir Length Area of Riser — Orifice in Riser Dia. of Orifice — Number of Orifices — Area of Orifice, (Ab) — Orifice Coefficient (Cd) — Inv. of Orifice — Length of weir — Top of weir — Weir Coefficient (Cw)— Width of Spillway (Approx.) — Weir Coefficient — Crest Elevation — Maximum Release Rate, (Qj) — Release Rate, (Qj) — Normal Water Surface Elev. — 1 15 inches 1.23 sf 50 feet 0.01980 289.50 feet 292.25 feet Width Weir— 48 inches 14.00 feet 12.00 sq. ft. 1.25 inches I 0.01 sf 0.60 289.50 feet 1.00 feet 291.10 feet 3.00 10 feet 3.3 292.50 feet 0.09 efs 0.05 efs 289.50 feet Water Surface Elev. @ Outlet (Qj) — 291.09 feet printed: 5/20/2021 8 51 AM Page 2 of 3 Peak Inflow, (Qp) => Time to Peak Calculation: CN Q*— vol— Time to Peak, (Tp) (SCS TR-55) 0.17 efs 80 p— 2.96 in. 1.22 in. (depth of runoff) 9,921 ef (vol. of runoff) 704.3 minutes S— 2.50 in. printed: 5/20/2021 8 51 AM Page 3 of 3 Cotswold Pond 42 Antiflotation Calculation Input Data Safety Factor: 1.50 Top Width of Riser (ft) 3.00 Top Length of Riser (ft) 4.00 Thickness of Riser (ft) 0.50 Thickness of Bottom of Riser (ft) 0.50 Top of Riser (ft) 292.25 Invert of Riser (ft) 289.50 Volume of Riser (cf) 22.50 Unit Weight Of Concrete (lb/cf) 150.00 Unit Weight of Water (lb/cf) 62.40 Block Height (ft) 0.00 Block Width (ft) 0.00 Block Length (ft), 0.00 Output Fw (Uplift Force, lb) 2059.20 Fc (Weight of Concrete,lb) 3375.00 Design Volume (cf), 22.50 Design Safety Factorl 1.64 Volume OK 1728-POND 2 Antiflotation.xls 5/20/2021 Cotswold Pond #2 Drawdown Time Temporary storage volume — Orifice #I diameter= Area of orifice Orifice #2 diameter Area of orifice Orifice Coefficient (Cd) Orifice elevation -- Water elevation --- Driving head (H) = Discharge (Q) — Drawdown time = 5,356 cf 1.25 in 1 0.0085 sf 0 in 0 0.0000 sf 0.60 289.50 ft 291.09 ft 0.53 ft 0.0299 cfs 179269 s 49.8 hr 2.1 days 1728-Drawdown.xlsx Printed 5/20/2021 Cotswold Pond N2 Storm Water Control SCS curve number Hydraulic Soil Group: B Area SCS CN Building (sf) 25,350 98 50,295 Driveways (sf) 6,669 98 Pavement (sf) 10,736 98 Pond (sf) 7,540 98 Open space (sf) 47,467 61 Offsite -open space (sf) 0 61 Offsite -impervious (sf) 0 98 Total (sf) 97762 80 Total (ac) 2.24 Rational Coefficient Predevelopme Postdevelopme Area C Area C Impervious (sf) 0 0.95 Building (sf) 25,350 0.95 Open space (sf) 619,528 0.30 Driveways (sf) 6,669 0.95 Pavement (sf) 10,736 0.95 Pond (sf) 7,540 0.30 Open space (sf) 47,467 0.30 Offsite -open space (sf) 0 0.3 Offsite -impervious (sf) 0 0.95 Total (ac) 619528 0.30 Total (ac) 97762 0.58 Total (ac) 14.22 Total (ac) 2.24 1728-Runoff coefficient calcs.xls Printed 5/20/2021 Cotswold Pond #2 Required Storm Volume Wet Pond Drainage Area: 2.24 acres Impervious Area: 50,295 sf (1.15 ac) % Impervious: 51.4% 1 inch Storm Event: Rv = 0.05+0.009 1 Rv = runoff coefficient I= percent impervious Rv=0.05+0.009*51.4% = 0.5126 For volume that must be controlled: Volume=3,630*Rd*Rv*A Volume = 3,630*(l inch)*(0.5126)*2.24 acres = 4,168 cf Temporary volume stored = 5,356 cf SA/DA ratio is 1.83 for a depth of 3.0 feet Required surface area = 2.24 ac * (0.0183) = 0.0410 ac or 1,786 sf Surface area provided (main permanent pool) = 2,779 s 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 1910-426-6777 fax 1910-426-5777 license number I C-2354 On time, every time. I www.4Dsitesolutions.com