Loading...
HomeMy WebLinkAboutSW8010507_APPROVED PLANS_20010629STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT. NO. SW DOC TYPE ❑CURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD AGENCY CONTACT LISTING GAS ELECTRIC NORTH CAROLINA NATURAL GAS CAROLINA POWER & LIGHT 347 MILITARY CUTOFF RD. WILMINGTON, N.C. 28403 404 RALEIGH ST. WILMINGTON. N,C, 28412 MS. MARY HARTSELL MR. BENNETT POTTER (800) 717-6539 (910) 350-2383 TELEPHQNE BELL SOUTH 3809 SHIPYARD BLVD. WILMINGTON, N,C. 284032 MR, KENNY SMITH (910) 392-8712 FIRE MARSHALL BRUNSWICK COUNTY EMERGENCY MANAGEMENT 3325 OLD OCEAN HWY. BOLIVIA. N.C. 28422 MR. SCOTT GARNER (910)253-4376 TRAFFIC ENGINEERING NORTH CAROLINA D.O.T. 429 MULBERRY ST. SHALLOTTE, N.C. 28470 MS. MICHELLE PODESZWA (910) 754-6527 SANITARY SEWER. D.H. INVESTORS POS 157 LELAND, N.C. 28451 MR. E. G. DALE (910) 371-6387 BUILDING, DEPARTMENT BRUNSWICK COUNTY INSPECTIONS DEPARTMENT 20 REFERENDUM DRIVE N.E, BOLIVIA, N.C. 28422 MR. DELANEY AYCOCK (910) 253-2050 PLUMBING BRUNSWICK COUNTY INSPECTIONS DEPARTMENT 20 REFERENDUM DRIVE N.E. BOLIVIA. N.C. 28422 MR. DELANEY AYCOCK (910) 253-2050 STORM DRAINAGE THE CITY OF LELAND CODE ENFORCEMENT 102 TOWN HALL DRIVE LELAND, N.C. 28451 MR. DAVID W. HEWETT (910) 371-0148 WATER NORTH BRUNSWICK SANITARY DISTRICT 516 VILLAGE RD, N.E. LELAND, N.C. 28451-1030 MS. JEAN G. SPEIGHT (910) 371-9949 PROJECT OWNER AND CONSULTANT OWNER/ APPLICANT ALPHA DEVELOPMENT GROUP 5306 SIX FORKS ROAD RALEIGH, NC 27609 (919)782-2727 ARCHITECT LITTLE & ASSOCIATES ARCHITECTS 5815 WESTPARK DRIVE CHARLOTTE, NC 28217 (704) 561-8700 MAIL ENGINEERING CONSULTANT KIMLEY—HORN AND ASSOCIATES, INC. 3001 WESTON PARKWAY CARY, NC 27513 MR. JIM BELL (919) 677-2122 SURVEYOR SHERWIN CRIBB, R.L.S. 1144 SHIPYARD BLVD. WILMINGTON, NC 28412 (91 O)791-0080 STORMWATER MANAGEMENT PLANS FOR pharmacy STORE NUMBER 5563-02 VILLAGE ROAD LELAND, NORTH CAROLINA N W E S O CLARKTON o CURRY 40 421 BOLTON O 74 CASTLE HAYNE • LELAND OWILMINGTON OSONSORO 211 MYRTL GROVE O BOILING SPRING LAKES PROJECT LOCH TION NOT TO SCALE PREPARED IN THE OFFICE OF: P.O. BOX 33068 - RALEIGH, PHONE: (919) 677-2000 N W E S SR, 14,72 4 SITE f PROJECT LOCH TION NOT TO SCALE K'Imley=Horn III and Associates, Inc. NORTH CAROLINA 27636-3068 FAX: (919) 677-2050 INDEX TO SHEETS sHee.l DESCRIPTION CS I COVER SHEET C3 I SITE PLAN C4 I GRADING, DRAINAGE AND EROSION CONTROL PLAN C9 EROSION CONTROL DETAILS e REVISIONS R=*7TEn �. a0NMEIfX _I QUALITY lwwatw Ferf lit 1, NO. DATE DESCRIPTION BY This document, together with the concepts and designs presented herein, as an instrument of services, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Horn and Associates, Inc. Copyright Kimley—Horn and Associates, Inc., 1999 DRAIMNQ 88303COO.dwg 5-17-00 3:01:04 pm EST DATE: MAY, 2001 SEAL: JOB NUMBER: 5-14-'D 012107001 4 E rS J 1 I1l �, f LLI J 0 0 0 fu 0 0 0 m L LL_ 0 U to C, 3t 6 O 1+ b C'U _ o Cn U O O GENERAL SITE NOTES A. ALL CONSTRUCTION SHALL CONFORM WITH APPLICABLE STATE AND LOCAL CONSTRUCTION STANDARDS AS IDENTIFIED IN THESE PLANS, THE CONTRACTOR SHALL MAINTAIN A CURRENT RELEASE OF THE STATE AND LOCAL LAND DEVELOPMENT STANDARDS MANUAL ON THE PROJECT SITE FOR REFERENCE DURING CONSTRUCTION OF THE PROJECT. B. ALL DIMENSIONS ARE TO EDGE OF PAVEMENT AND FACE OF CURB UNLESS OTHERWISE NOTED. C. ALL PAINT STRIPING, PAVEMENT MARKINGS, AND SIGNAGE SHALL CONFORM TO THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" OR AS OTHERWISE SPECIFIED. ALL REFERENCED SIGN STANDARDS ARE TAKEN FROM THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES". ALL NEW SIGNS SHALL BE MOUNTED ON GALVANIZED POSTS AND IN ACCORDANCE WITH STATE AND LOCAL REGULATIONS. D. THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES DURING CONSTRUCTION. AT LEAST 48 HOURS PRIOR TO ANY DEMOLITION. GRADING, OR CONSTRUCTION ACTIVITY THE CONTRACTOR SHALL NOTIFY THE NORTH BRUNSWICK SANITARY DISTRICT AT (910) 341-9949 FOR PROPER IDENTIFICATION OF EXISTING UTILITIES WITHIN THE PROJECT SITE. E. THE CONTRACTOR SHALL VERIFY DIMENSIONS AT JOBSITE, F, CONTRACTOR SHALL INSTALL ACCESSIBLE RAMPS PER TOWN OF LELAND AND ADA STANDARDS AT ALL DRIVE AND BUILDING LOCATIONS AS REQUIRED. G. CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION CONTROL DEVICES SHOWN ON THE APPROVED PLANS FOR THE DURATION OF CONSTRUCTION OR UNTIL FINAL INSPECTION. H. CONTRACTOR SHALL VERIFY LOCATION AND DEPTH OF EXISTING STORMWATER STRUCTURES. CONTRACTOR SHALL NOTIFY ENGINEER IF EXISTING CONDITIONS DO NOT MATCH INFORMATION ON PLANS. I. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF —SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS. J. NON—STANDARD ITEMS (IE: PAVERS, IRRIGATION SYSTEMS, ETC.) IN THE RIGHT—OF—WAY REQUIRE A RIGHT—OF—WAY ENCROACHMENT AGREEMENT WITH THE STATE AND LOCAL TRANSPORTATION DEPARTMENTS BEFORE INSTALLATION. MAP NOTE: ALL EXISTING BOUNDARY AND TOPOGRAPHIC INFORMATION TAKEN FROM A LAND SURVEY PREPARED BY: SHERWIN D. CRISS. ENTITLED: CVS #5563, DATED 4-4-2001. SITE AREA: BUILDING AREA: PARKING REQUIRED (1 SPACE/200 SO. FT. RETAIL - PARKING PROVIDED: ZONING: DENUDED AREA LEGEND 2.04 AC. 10,880 SO. FT 54 SPACES 74 SPACES C-2 (REGIONAL COMMERCIAL) 1.94 AC. PAINTED TRAFFIC ARROW e •� ' e CONCRETE SIDEWALK -r PROPOSED TRAFFIC SIGN PROPOSED CVS DIRECTIONAL SIGN OPROPOSED PARKING COUNT AREAS OF PROPOSED HEAVY DUTY ASPHALT PRELIMINARY NOT FOR CONSTRUCTION E. G. BALE w c} VIDEO STORE "ENTER" SIGN — DUMPSTER PAD E� POSSIBLE 12' LANE ADDITION A UTO PARTS STORE FUTURE NCDOT ROW 49- R-1641.5 f # ii [I j u J 11 II I f 1 } ! it +I !1 II Ir it i1 ++ li [I 1 ii rl 'r I it if li I I (I li fl ! I! [f } !f I WOODBRIDGE CO. I 1 I sr R-'927 36. L GRAPHIC SCALE PROPOSED TRAFFIC SIGNAL �-- _ 30 0 13 30 60 120 i ( IN FEET ) I inch = 30 ft l' Q Qz_ CD� 4D Y 0 CCU Q Q O 0 z= o� Cl] w 0 r r_ 0 0 Q 51C CZ In CONSULTANT: KIMLEY—HORN AND ASSOC. 3001 WESTON PARKWAY CARY, NC 27513-2301 TEL (919) 677-2000 FAX (919) 677-2050 SEAL: !�-'IAya I CVS/ rv--% poh&[Fgn&@y STORE NUMBER: 5563 VILLAGE RD LELAND, NC 28541 OWNER/DEVELOPER: ALPHA DEVELOPMENT GROUP 5306 SIX FORKS ROAD RALEIGH NC 27609 OFFICE: (919) 782-2727 FAX: (919) 782-2726 REVISIONS: LAYOUT COORD: JAB PLANNING MGR. JAB DRAWING BY: TLM DATE: 5— 4-01 JOB NUMBER: 012107001 TITLE: SITE PLAN SHEET NUMBER: C�3 COMMENTS: NOT FOR CONSTRUCTION GENERAL NOTES A. ASPHALT TO DRAIN AS SHOWN. B. ALL SPOT ELEVATIONS SHOWN ARE TO GUTTER ELEVATION AT FACE OF CURB OR CONCRETE ELEVATION AT FACE OF ISLAND UNLESS OTHERWISE NOTED. C. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF -SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS. D. NON-STANDARD ITEMS (IE; PAVERS, IRRIGATION SYSTEMS, ETC.) IN THE RIGHT-OF-WAY REQUIRE A RIGHT-OF-WAY ENCROACHMENT AGREEMENT WITH THE STATE AND LOCAL TRANSPORTATION DEPARTMENTS BEFORE INSTALLATION. EROSION CONTROL NOTES A. EROSION CONTROLS SHALL BE INSTALLED PRIOR TO CONSTRUCTION AND SHALL BE ADEQUATE TO MAINTAIN SEDIMENT ON SITE. B. ALL EXCAVATED SOILS NOT NEEDED ON SITE FOR BACKFILL OPERATIONS SHALL BE TAKEN OFF SITE AND LEGALLY DISPOSED OF. C. SOIL REMAINING ON SITE SHALL HAVE SILT FENCE TIGHTLY PLACED AROUND THE ENTIRE CIRCUMFERENCE OF THE PILE. D. PROVIDE EROSION CONTROLS AS NECESSARY TO PREVENT IT FROM GETTING OF SITE OR INTO EXISTING DRAINAGE STRUCTURES. E. ERECTION OF EROSION CONTROLS SHALL BE IN ACCORDANCE WITH STATE AND LOCAL EROSION CONTROL REGULATIONS. MAP_ N QTE: ALL EXISTING BOUNDARY AND TOPOGRAPHIC INFORMATION TAKEN FROM A LAND SURVEY PREPARED BY. SHERWIN D. CRIBB, ENTITLED: CVS #5563, DATED 4--4-2001. GRADING LEGEND 100 -_ - 100 ----- too,00 x100.00 -SF SF-- - TF TI =-- ww PROPOSED CONTOUR EXISTING CONTOUR PROPOSED SPOT ELEVATION EXISTING SPOT ELEVATION FLOW ARROW SILT FENCE TREE PROTECTION FENCE INLET PROTECTION CATCH BASIN RCP PIPE DRAINAGE AREA PRE DEVELOPMENT DISCHARGE FOR 25 YEAR STORM (925) AREA AC. RATIONAL RUNOFF COEFFICIENTS C INTENSITY IN R 025 CF5 TYPE OTY. BUILDING ASPHALT 0.03 0.9 *8.0 0.22 EXIST. GRASS AREA 2.25 0.40 *8.0 7.20 TOTAL 1 2.28 **7.42 * 25 YEAR RATIONAL INTENSITY VALUE FOR WILMINGTON N.C. ** 025 - TOTAL AREA (AC)* CC* INTENSITY (IN/HR) POST DEVELOPMENT DISCHARGE FOR 25 YEAR $TQRM.,(25 AREA AC. RATIONAL RUNOFF COEFFICIENTS C INTENSITY IN/HR 025 CFS TYPE OTY. DEVELOPED AREA 1.85 0.74 48.0 **11100 POND AREA 0.43 0.44 *8.0 1.51 POND DETENTION - 5.19 TOTAL 2.28 ***7.32 * 25 YEAR RATIONAL INTENSITY VALUE FOR WILMINGTON N.C. ** 025 - DRAINAGEL AREA (AC)* C * INTENSITY (tN/HR), VALUE DETERMINED USING STORMCAD CALCULATIONS (SEE REPORT) *** 025 ROUTED THRU POND PRELIMINARY NOT FOR CONSTRUCTION 1K t BASIN DIMENSIONS WET BASIN SIZE ELEV. WIDTH LENGTH AREA (SF) 0 BANK 25' 55' 182' 10,010 O PERMANENT POOL 22' 37' 164' 6,068 0 SHELF ENDING 20.5' 19' 146' 1 2,774 0 BOTTOM 18,5' 7' 134' 1 938 ZONING_ C--2 PROPOSED 1� 51 r +,, }• PROPOSED ►!;, ''; ;r' SHOPPING CENTER PARKING LOTASPHALT PAVEMENT PAVEMENT (BY OTHERS) I � I 5 ilk :'N' TNI t o I y �fr it i rrt , ,r 1 • ,I , iii ` � u 1 , / ' to , �r 5 It 4 I, WOODBRIDGE CO. rr ,� ` 1f I rl ,;1. 't, I rr y M y !,`, ,, CENTER -- _ -- - 4 _ ; ` y _ SHOPPING _ _ � / PARKING LOT ASPHALT PAVEMENTLLLLjLL (BY OTHERS)PRIVA oNSTR BE C -------------- 25 INV, OUT ■ 18.50 I i ` CB 3, NCDOT ; INDEX N0. 640.02 I T/C - 25.25 i! INV. IN - 19.25 n INV. OUT - 19.15 � 11 1 1 1 I co 6�1 I 1 Q: ZONING: C-2 � n N PAVED PARKING LOT � w 7 I I I I E. G. DALE cn w � i iol 1 INV. OUT - 20.60 1 I q° I I f; I DROP INLET 1 I I I TOP 23,61 I 1,1-1 V _ INV. 20.36 ` 1 {1 1 1 • I 15" 0 C.P.P,-- ' U RIPRAP OUTLET PROTECTION � .- 6" STONE, IS- THICK 71 91 x 10.5`W INV, 15"0 C.P.P. 19.1---- ; 4% C.M.P. INV. 2 ; WATER M�T��---� -- ;-;� << �J 24"0 EDGE 4F PAVEMENT _ -�L DROP INL' T ' TOP 23.92 5 V' INLET INV. 19':92 IN TOP 22.60 INb'. 102 OUT INV. 19,21 IN - JL 1 --- JJ 20 ' v /lye 2s.so i - PROPOSED------------------ 82'-18 RCP 0.797i ♦ ��% 10,880 SF INLET - PROTECTI �t CONNECT TO "_ '• -'` �,=," ROOF DRAINS ip 26. sslei 1 '- - , 0 RC'!r' CTI DIA. RISER�11 43-"i8" RCP � 5.50 i 1r 1, NCDOT INDEX NO 840.02 r f ! I T/C - 25.50- ,,�.'r'i'` INV. OUT 21.90 fvD, z r P L CTION ZONING: C-2 CONC TE FL ME r \ Nil I ,.a: jE I E. G. DALE if 1 SO �I� I ri '{= y 1 W INLET I / aD0 ff f PROTECTION ♦ r I 2 CONCRETE FLUME rfI /1 rf I t {+ FUTUR 60T 1 ¢rh � � -- _ - ---- - `Z I � r AUTO FARTS VIDEO STORE STORE GRAPHIC SCALE ZONING: C-2 39 o is 30 so t2o ( IN FEET ) 1 inch - 30 ft 27 ------------------------------------------- -- CB 0 2, NCDOT INDEX NO. 840.02 T/C - 25.15 INV, IN - 21.50 8"}" INV. IN - 20.65 �18 ) INV. OUT - 20.55 (18") Nm NO WETLANDS EXIST WITHIN PROJECT BOUNDARIES r Q a N C7? N � A O U z � N W � PAV_ ■ V � N try .�. CO Q Z 3: J YO L 1;rs . ■r Q Q 0- U To o Z= O rJ..rCO w Oct LyJ Z LA :�e as POO U CONSULTANT: KIMLEY-HORN AND ASSOC. 3001 WESTON PARKWAY CARY, NC 27513- 2301 TEL (919) 677-2000 FAX (919) 677-2050 SEAL: s/4-101 (pharmacy STORE NUMBER: 5563 VILLAGE RD LELAND NC 28541 OWNER/DEVELOPER: ALPHA DEVELOPMENT GROUP 5306 SIX FORKS ROAD RALEIGH NC 27609 OFFICE: (919) 782-2727 FAX: (919) 782-2726 REVISIONS_ LAYOUT COORD: JAB PLANNING MGR. JAB DRAWING BY: TLM DATE: 5-4-01 JOB NUMBER: 012107001 TI TLE: GRADING, DRAINAGE, & EROSION CONTROL SHEET NUMBER: C�4 COMMENTS: NOT FOR CONSTRUCTION V Ll CONSTRUCTION SCHEDULE J. OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM THE TOWN OF LELAND ENGINEERING DEPARTMENT. 2. SET UP AN ❑N-SITE PREC❑NSTRUCTION CONFERENCE WITH EROSION CONTROL INSPECTOR OF THE TOWN ENGINEERING DEPARTMENT (PH.910 371-0148) TO DISCUSS EROSION CONTROL MEASURES. 3. INSTALL SILT FENCE, INLET PROTECTION, SEDIMENT TRAPS, DIVERSION DITCHES, TREE PROTECTION, AND OTHER MEASURES AS SHOWN ON PLANS, CLEARING ONLY AS NECESSARY TO INSTALL THESE DEVICES. 4. CALL (910) 371-0148 FOR ON -SITE INSPECTION BY ENGINEERING INSPECTOR. WHEN APPROVED, ENGINEERING INSPECTOR ISSUES THE GRADING PERMIT. BEGIN CLEARING AND GRUBBING AFTER PERMIT ISSUANCE. 5. MAINTAIN EROSION CONTROL DEVICES AS NEEDED. 6. FOR PHASED EROSION CONTROL PLANS, CONTRACTOR SHALL MEET WITH EROSION CONTROL INSPECTOR PRIOR TO COMMENCING WITH EACH PHASE OF EROSION CONTROL MEASURES. 7. STABILIZE SITE AS AREAS ARE BROUGHT TO FINISH GRADE. 8. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, U.S. DEPT. OF AGRICULTURE, U.S. SOIL CONSERVATION SERVICE, TOWN OF LELAND EROSION CONTROL ORDINANCE, AND THE TOWN OF LELAND ENGINEERING DEPARTMENT. 9. THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES TO MINIMIZE EROSION. THE CONTRACTOR SHALL MAINTAIN CLOSE CONTACT WITH THE TOWN OF LELAND EROSION INSPECTOR SO THAT PERIODIC INSPECTIONS CAN BE PERFORMED AT APPROPRIATE STAGES OF CONSTRUCTION. SEEDING SCHEDULE (REVISED: 1-1-86) Shoulders, Side Ditches, Slopes (Max 3:1) DATE TYPE PLANTING RATE Aug 15 - Nov 1 Tall Fescue 300 Ibs/acre Nov 1 - Mar 1 Tall Fescue 30D Ibs/acre & Abruzzi Rye 25 Ibs/acre Mar 1 - Apr 15 Tall Fescue 300 Ibs/acre Apr 15 - Jun 30 Hulled Common Bermudogross 25 lbs/acre Jul 1 - Aug 15 Tall Fescue and 120 Ibs/acre ***Browntop Millet 35 Ibs/acre ***or Sorghum -Sudan Hybrids 30 Ibs/acre Slopes (3:1 to 2:1) Mar 1 - Jun 1 Sericea Lespedeza (scarified) 50 Ibs/acre & (Mar 1 - Apr 15) Add Tall Fescue 120 lbs/acre (Mar 1 - Jun 30) Or Add Weeping Lovegrass 10 Ibs/ocre (Mar 1 - Jun 30) Or Add Hulled Common Bermudograss 25 Ibs/acre Jun 1 - Sep 1 ***Toll Fescue and 120 Ibs/acre ***Browntop Millet 35 Ibs/ocre ***or Sorghum -Sudan Hybrids 30 Ibs/acre Sep 1 - Mar 1 Sericeo Lespedeza (unhulled-unscarified) 70 Ibs/acre and Tall Fescue 120 Ibs/acre (Nov 1 -- Mar 1) Add Abruzzi Rye 25 Ibs/acre Consult Conservation Engineer or Soil Conservation Service for additional information concerning other alternatives for vegetation of denuded areas. The above vegetation rates are those which do well under local conditions; other seeding rate combinations are possible. ***Temporary - Reseed according to optimum season for desired permanent vegetation. Do not allow temporary cover to grow over 12" in height before mowing, otherwise fescue may be shaded out. SEEDBED PREPARATION 1.) CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2.) RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3.) REMOVE ALL LOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4.) APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL (SEE BELOW*). 5.) CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 6.) SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTtPACK AFTER SEEDING. 7.) MULCH IMMEDIATELY AFTER SEEDING ANDANCHOR MULCH. 8.) INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE.IF STAND SHOULD BE OVER 60% DAMAGED, REESTABLISH FOLLOWING ORIGINAL LIME, FERTILIZER AND SEEDING RATES. 9.) CONSULT CONVERSATION INSPECTOR ON MAINTENANCE TREATMENT AND FERTILIZATION AFTER PERMANENT COVER IS ESTABLISHED. * APPLY; AGRICULTURAL LIMESTONE - 2 TONS/ ACRES (3 TONS/ ACRE IN CLAY SOILS) FERTILIZER - 1,000 lbs. / ACRE-10-10-10 SUPERPHOSPHATE- 500 Ibs> / ACRE -20% ANALYSIS MULCH -2 TONS / ACRE - SMALL GRAIN STRAW ANOTHER - ASPHALT EMULSION ® 300 GALS./ ACRE I 1.5' max CURB INLET WIRE MESH i•��������i Sri ���1�t�.+it������ `.�,����,_"�`�i# OVERFLOW SEDIMENT LADEN RUNOFF WIRE SCREEN __J 2' X 4" STUD BRACE CURB INLET ems: 1. TWO CONCRETE BLOCKS SHALL BE PLACED ON THEIR SIDES ABUTTING THE CURB AT THEIR SIDE OF THE INLET OPENING. A 2-X4- STUD SHALL BE CUT AND PLACED THROUGH THE OUTER HOLES OF THE SPACER BLOCKS TO BRACE THE FRONT BLOCKS. FRONT BLOCKS ARE PLACED ON THEIR SIDES ACROSS THE INLET AND ABUTTING THE SPACER BLOCKS.. 2. OUTSIEE HARDWARE HI FACE COMPARABLE OF THEEBLIOCKS rD PREVENTNFILTER STONE FSHALL BE ROM PLACED BEING WASHED THROUGH HOLES IN THE BLOCK. 3. WASHED STONE PER SATE AND LOCAL SPECIFICATIONS SHALL BE PILED AGAINST THE WIRE TO THE TOP OF THE BLOCK. 4. CHECK DEVICE AFTER EACH RAIN. REPLACE WASHED STONE IF IT CLOGS WITH SEDIMENT. 5. APPLICABLE AT CURB INLETS WHERE AN OVERFLOW CAPABILITY 15 NECESSARY TO PREVENT EXCESSIVE PONDING IN FRONT OF THE INLET. BLOCK AND GRAVEL CURB INLET SEDIMENT FILTER 2 X 4" wood frame DrOD inlet 3' min. NOT TO SCALE •ame Stake Buried Fabric Installation of fabric and supporting frame for inlet protection. NOT TO SCALE NOM 1. 6:1 VEGETATED SHELF & TOP OF BERM TO BE P ANTED WITH D NCDENR BMP B M PLANT LIST. 2. REMAINDER OF POND AND RM TO BE SEEDED WITH - i TEMPgMARY POOL EL. i PERMANENT POOL EL. -NOTES-: In spite of pre:autions, some damage to protected trees may occur. In such cases repair any damage to the crown, truck or root system immediately. - Repair rots by cutting off the damaged areas and painting them with tree paint. Spread peat moss or moist topsoil over exposed roots. - Repair damage to bark by trimming around the damaged areas as shown in Figure 6.04b, taper the cut to provide drainage, and paint with tree paint. Cut oii'-ai, damaged tree limbs above the tree Collar at the trunk or main branch. Use three separate cuts as shown in Figure 6.05c to avoid peeling bark fron healthy areas of the tree. Incorrect Correct Barrier should be installed at the drip line of tree branches (modified from NJ). EXAMPLE OF TREE PROTECTION FENCING NOT TO SCALE aWASHED STONE PER STATE AND LOCAL SPECIFICATIONS TO BE USED. PAD TO BE 501 X 20'w X 6' D AT A MINIMUM. b. TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGE TRUCKS IS TO BE PROVIDED. a. ENTRANCE(S) SHOULD BE LOCATED TO PROVIDE FOR MAXIMUM UTILITY BY ALL CONSTRUCTION VEHICLES. d. MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. PERIODIC TOPDRESSING WITH STONE SILL BE NECESSARY: KEEP SOME HANDY. e. ANY MATERIAL WHICH STILL MAKES IT ONTO THE ROAD MUST BE CLEANED UP IMMEDIATELY. _6 NOTES: APPLICABLE AT ALL POINTS OF INGRESS & EGRESS UNTIL SITE IS STABILIZED, FREQUENT CHECKS OF THE DEVICE AND TIMELY MAINTENANCE MUST BE PROVIDED. TEMPORARY CONSTRUCTION ENTRANCE CONTRACTOR TO STRAPMETAL HARDWARE CLOTH & SILT FENCE F.EIRIC AROUND ENTIRE RISER STRUCTURE DUR110 CONSTRUCTION, REMOVE CLOTH & FENC,* FOLLOWING THE COMPLETION OF CONSTUCTION, COMPACED SELECT BACKFILL TO BE PLACED IN V-8 LAYERS AND COMPACED TO 95% STANDARD - PROCTOI MAXIMUM DRY DENSITY. RM FL. 25.0 OF FORE BAY INTALL 3 - 7 3"I ORIFICE P%R PIPE WITH E141CAP, PROVIDE A OF :NDCAP. TER TO STRAY METAL HARDWARE FENCE raRIC OVER :E DURIIN CONSTRUCTION. H FOLLOVNG THE )F CONSTUCTION. 8 DETENTION POND DETALS C - 9 NOT TO SCALE NOT TO SCALE V LANDSCAPE ZONE IN MIDDLE OF BERM ALL THE WAY AROUND THE POND r-METAL GRATE/TRASH RACK 18" RCP INSTALL CMP V-O' BELOW BASIN GRADE, FILL CMP w/ CONCRETE AS ANTI -FLOATATION DEVICE r8+OCMAX -'I 1) TOTAL DRAINAGE AREA FLOWING FENCE MAY NOT EXCEED 1 ACRE. SILT FE1�E 2) SILT FENCES SHOULD NOT BE USED AT PIPE OUTLETS OR IN AREAS OF CONCENTRATED FLOW t ((/ FLOW OF WATER (CREEKS, DITCHLINES, SWALES l 1 1 ETC.) ORE Pa TO INCREASE STORAGE CAPACITY AND SEIDOEVO S, PROLONG THE LIFE OF THE SILT FENCE, IT IS GENERALLY ADVISABLE TO DIG A 1 SEDIMENT PIT IN FRONT OF YOUR LIST o FENCE WHENEVER POSSIBLE. 12 GAUGE 4"X4" OR 2N4" WELDED WIRE HOOKED ONTO PREFORMED CHANNELS ON METAL POSTS. OR FASTENED TO CEDAR OR WOOD POSTS W/ NO.8 STAPLES. • ULTRAVIOLET RESISTANT (BLACK) MIRIFI FABRIC OR EQUIVALENT SECURED TO WIRE W/ METAL CLIPS OR WIRE AT 8' OFF CENTER. • MAX. SEDIMENT STORAGE LEVEL. REMOVE ' SEDIMENT WHEN THIS LEVEL 15 REACHED OR o • a" • AS DIRECTED BY CONSERVATION INSPECTOR. • - - TRENCH, COVER W/ SOIL & TAMP BACKFILL. * - - - - - - - - SHEET DRAINAGE (ONLY) . ___________ - - - - - - - - - - - NATURAL GRADE CARRY APPROX.12' OF FABRIC INTO 1- CARRY 5" OF WIRE INTO TRENCH. METAL, CEDAR OR 4"X4` TREATED WOOD POSTS AT 10'O.C. MAX.. CEDAR & WOOD POSTS SHOULD BE 3' DEEP MIN. SILT FENCE FOR SMALL DRAINAGE 3 AREA LESS THAN ONE ACRE C - 9 NOT TO SCALE J PLAN La d NOTES! SECTION A -A Filter blanket SEE APPROPRIATE SCI EDUL E MR ONMENS10NS 1. La is the length of the riprop apron. 2. d - 1.5 times the maximum stone diameter but not less than 6" 3. In well-defined extend the apronup the channel banks to on elevation of 5" above the maximum tailwoter depth or to the top of the bank which ever is less. 4. A filter blanket or filter fabric should be installed between the riprop and soil foundation. OUTLET PROTECTION FOR DEFINED CHANNEL f 0 N i� r- L0 r C3 I`�_ N CO v► 0) a1 a OCD Q Z y0 Of Q Q O O z 0 = 1 � Cn Q 0 �z 0 r--- Co 0 of U CONSULTANT: KIMLEY-HORN AND ASSOC. 3001 WESTON PARKWAY CARY, NC 27513-2301 TEL (919) 677-2000 FAX (919) 677-2050 SEAL: 57 Ste 1 STORE NUMBER: 5563 VILLAGE RD LELAND NC 28541 OWNER/DEVELOPER: ALPHA DEVELOPMENT GROUP 5306 SIX FORKS ROAD RALEIGH NC 27609 OFFICE: (919) 782-2727 FAX: (919) 782-2726 REVISIONS: LAYOUT COORD: JAB PLANNING MGR. JAB DRAWING BY: TLM DATE: 5-4-01 JOB NUMBER: 012107001 TITLE: EROSION CONTROL DETAILS SHEET NUMBER: C-9 COMMENTS: NOT FOR CONSTRUCTION