Subject: REQUEST FOR ADDITIONAL INFORMATION
Stormwater Project No. S W 8 001027
Lowe's Foods Pine Grove Drive Site
New'Hanover County
Dear Mr. Garrett:
The Wilmington Regional Office received a Stormwater Management Permit Application for Lowe's
Foods Pine Grove Drive Site on October 24, 2000. A preliminary review of that information has determined
that the application is not complete. The following information is needed to continue the stormwater review:
Delineate all wetlands on site, disturbed or undisturbed, or note on the plans that none exist
2. Is Southport Trading Company an LLC? Please indicate what kind of company it is .on the
application.
3. :Since: two�supple,ments.have•be'en"pr'ovi'ded, there must beat least.two columns filled in.on the
-application, one for the trench and.one for,the'basin. There'is no symbol in -the legend and no
note-on.the plans to indicate that.a•trench is provided, anywhere.
4. Is the flat grade piping -supposed to be the proposed trench system? The current design seems
to use the flat grade perforated piping as the primary treatment, with any overflows going into
.the basin. You;cawhave both the treneb:and the•basin, but each one must -be a separate system,
.sized individually -to accommodate it's separate drainage area. The outlet and overflow must also
be.separate. ,The,trenchesshould.overflow.to.a�vegetated filter instead of the basinAf.you'keep
,the current:setup,"the basin will.need.tobe sized for the entire drainage:area,"as'if the,trenches
-weren't there, -just`like,two ponds in series. The last system7in line has to:be sized for.everything.
I cannot verify calculations until this'is resolved.
4. Please provide an infiltration basin detail on the plans. Include the 3:1 side slopes, and note the
bottom and storage elevations.
S. Please add.a detail of the.required vegetated filter to the plans.
6. A large portion of the perimeter collection piping is:laid at a flat grade. •How .will,this work in
regards to directing runoff into the'infiltration basin for treatment? Is -this piping part of the
unlabeled proposed trench? If -so, please.label. I-wi11 consult with Raleigh -regarding the flat
grade of the proposed collection system. If you separate the trench and basin systems, the flat
grade will be OK.
127 Cardinal Dr. Ext., Wilmington, North Carolina 28405 Telephone 910-395-3901) FAX 910-350-2004
An Equal Opportunity Affirmative Action Employsr 50'% recycledl10% post -consumer paper
Mr. Garrett
December 11, 2000
Stornwater Project No. SW8 001027
7. The intersection of Oleander Drive and South College needs to be added to the vicinity map. The
rules require the nearest major intersection be shown.
Please provide existing grades at Sycamore Hollow to demonstrate that no offsite runoff from
this site enters the proposed basin. There is no existing ditch between the two properties, so the
possibility of offsite runoff does exist.
9. Based on the grading shown at Sycamore Hollow, a low area will be formed behind Units 313
and 4A, with no proposed outlet for the runoff that will accumulate. Please address.
10. Please specify the stone to be used in the trench, and provide it's specification sheet. A void ratio
of 0.55 is definitely not normal, which is around 0.4.
Please note that this request for additional information is in response to a preliminary review. The
requested information should be received by this Office prior to January 11, 2001, or the application will be
returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the
application fee.
If you need additional time to submit the information, please mail or fax your request for a time
extension to the Division at the address and fax number at the bottom of this letter. The request must indicate
the date by which you expect to submit the required information. The Division is allowed 90 days from the
receipt of a,completed.appliication to issue the permit.
The -construction of any impervious: surfaces, other.than a construction entrance under:an.approved
Sedimentation Erosion •ControlTlan, is a violation ofNCGS 143-215.1 and.is subjectao enforcement action
pursuant to NCGS -143-21.5,6A.
}Tease reference the -State assigned project number on all correspondence. Any original documents that
need to be revised have been sent to the engineer or agent. All original documents must be returned or.new
originals must be provided. ,Copies are not acceptable. -If you have any questions concerning this matter please
.feel free -to call me.at:(91.0) 395-3900.
Sincerely,
�cj,at, odw,-�
Linda Lewis
Environmental Engineer
RSS/arl: S:IWQSISTORMWATIADDINFO\001027.DEC
cc: Linda Lewis
Phil Non -is,
127 Cardinal Dr..Ext., Wilmington, North Carolina 28405 'telephone 910-395-3900 FAX 910-350-2004
An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper
A5
���
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Beverly Eaves Perdue Coleen H. Sullins
Governor Director
March 29, 2011
Mr. Nick Garrett, Jr., Managing Member
Southport Trading Company, LLC
P. O. Box 4893
Wilmington, NC 28406
Subject: Permit Extension, Session Laws 2009-406 and 2010-177
Stormwater Permit #SW8 001027
High Density — Lowe's Food — Pine Grove
New Hanover County
Dear Mr. Garrett:
Dee Freeman
Secretary
On August 5, 2009, the Governor signed Session Law 2009-406. This law impacts any
development approval issued by the Division of Water Quality under Article 21 of
Chapter 143 of the General Statutes, which is -current and valid at any point between
January 1, 2008, and December 31, 2010. The law extends the effective period of any
stormwater permit that is set to expire during this time frame to three (3) years from its
current expiration date. On August 2, 2010, the Governor signed Session Law 2010-
177 which grants an extra year for a total of four (4) years extension.
Accordingly, Stormwater Permit # SW8 001027 which has already expired on February
13, 2011, is now in effect until February 13, 2015. Please resubmit the renewal
application and fee. at least 180 days prior to February 13, 2015, which would be August
13, 2014. A copy of the Renewal Application can be obtained from the following
website: httpalportal.ncdenr.org/web/wq/ws/su/statesw/forms—docs,
If you have any questions, please contact the Division of Water Quality in the
Wilmington Regional Office at 910-796-7215.
Sincerely,
Georgette Scott
Stormwater Supervisor
Division of Water Quality
S:WQSISTORMWATERIRENEWALSISL2009-406 2010-177\001027.marl 1
cc: Wilmington Regional Office
Wilmington Regional office
127 Cardinal Drive Extension, Wilmington, North Carolina 28405 One
Phone: 910-796-72151 FAX:910-350-2t)04 4 Customer Service: 1-877.623-6748 NorthCarolina
interne[: wvuw.ncwaterquaiity.org ,/
An Equal Opportunity l Affirmative Action Employer V trtunT J
=CJPh
�
NC®ENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Beverly Eaves Perdue Coleen H. Sullins
Governor I Director
February 23, 2010
Mr. Nick Garrett, Jr., Managing Member
Southport Trading Company, LLC
P. O. Box 4893
Wilmington, NC 28406
Subject: PERMIT RENEWAL REQUEST
Stormwater Permit No. SW8 001027
Lowe's Foods -Pine Grove Drive
New Hanover County
Dear Mr, Garrett:
Dee Freeman
Secretary
The Division of Water Quality issued a Coastal Stormwater Management Permit, Number SW8 001027 to Lowe's
Foods — Pine Grove Drive for a High Density Project on February 13, 2001. This permit expires on February 13, 2011.
Per 15A NCAC 2H.1003(h) (the stormwater rules), applications for permit renewals shall be submitted 180 days prior
to the expiration of a permit and must be accompanied by a processing fee, which is currently set at $505.00. If this is
still an active project please complete and submit the enclosed renewal application prior to August 13, 2010. If this
project has not been constructed and a permit is no longer needed, please submit a request to have the permit
-escinded. If you have sold the project, or are no longer the permittee, please provide the name, mailing address and
phone number of the person or entity that is now responsible for this permit. Enclosed is a form for change of
ownership, which should be completed and submitted if the property has changed hands.
Your permit requires that upon completion of construction and prior to operation of the permitted stormwater treatment
system, a certification of completion be submitted to the Division from an.appropriate designer for the type of system
installed. This is to certify that the permitted facility has been installed in accordance with the permit, the approved
plans, specifications and supporting documentation. Please include a copy of the certification with your permit renewal
request and processing fee. Enclosed is a copy of a sample certification. Also enclosed is a new Operation and
Maintenance agreement that should be completed and submitted along with your renewal application.
You should be aware that failure to provide the Designer's Certification and the operation of a stormwater treatment
facility without a valid permit, are violations of NC General Statute 143-215.1 and may result in appropriate
enforcement action including the assessment of civil penalties of up to $10,000 per day.
If you have any questions, please feel free to contact David Cox at 910-796-7318.
Sincerely,
Georgette Scott, Stormwater Supervisor
Surface Water Protection Section
Wilmington Regional Office
Enclosures
GDSldwc S:\WQS\Stormwater\Renewal\Reques ts\2001\001027.febl0
cc: Wilmington Regional Office File
Wilmington Regional Office
127 Cardinal Drive Extension, Wilmington, North Carolina 28405 One
Phone: 910-796-72151 FAx 910-350-20041 Customer Service: 1-877-623-6746 NorthCarolina
Intemei: www.ncwaterquality.org
Ar Equal Opportunity 1 Affirmative Action Employer � ������
— Andrew & Kuske
— — = CONSULTING ENGINEERS, INC.
John R. Andrew, RE,
J. A. Kuske, P.E.
J. Phillip Norris, P.E.
902 Market St. • Wilmington, North Carolina 28401-4733 • Telephone 910/343-9653 • Fax 910/343-9604 • www.andrewandkuske.com
January 5, 2001
Ms. Linda Lewis
NCDENR1Div. of Environmental Mgmt.
127 Cardinal Drive Extension
Wilmington, NC 28405-3845
Re: Lowes Foods
Pine Grove Drive Site
SW8 001027
New Hanover County
Additional Information
A&K No. 99272
Dear Ms. Lewis:
JAN 18 2001
We are responding to your letter of December 11, 2000 and subsequent fax of January
3, 2001 as follows:
1. It has been noted on the plans that no wetlands exist on the site.
2. Southport Trading Company is a LLC.
3. As we discussed, the 1.5-inch storage will be provided entirely in the trench system.
The trench system has been classified on the plans.
4. As previously discussed, the trench system will contain the 1.5-inch storage
requirements.
4a. The infiltration basin is for City of Wilmington storage requirements only.
5. Due to the system capability to contain the 25-year, 24-hour storm, no vegetated
filter is required.
6. As previously discussed, the infiltration basin is not part of the state system.
7. The vicinity map has been modified per your request.
Ms. Linda Lewis
January 5, 2001
Page 2
8. A swale has been added to eliminate the possibility of off -site water from entering
the basin.
9. The swale noted in item 8 above will allow drainage of this area.
10. The void ratio will be 0.4 for the stone. The total trench void ratio is now 51.7%.
As indicated in your memo of January 3 we have added another baffle wall in the outlet
structure to separate the trench system from the basin system.
We are enclosing 2 sets of revised plans and calculations for your review and approval.
Please let us know if you need any additional information.
Sincerely,
ANDREW & KUSKE
CONSULTING -ENGINEERS, IN
4 !/i'
hillip rris, P.E.
Pete Avery
Enclosures
99272-1-O5-01 ftr
'4 * * * COMMUNICATION RESULT REPORT ( JAN. 3.2001 10:41AM )
P. 1
FILE MODE OPTION
T002 MEMORY TX
------------------------------------
REASON FOR ERROR
E-1) HANG UP OR LINE FAIL
E-3) NO ANSWER
State of North Carolina
Department of Environment
and Natural Resources
Wilmington Regional Office
James B. Aunt, Jr., Governor
Bill Holman, Secretary
Division of Water Quality
Wilmington Regional Office
Date: January 3, 2001
To: Phil Norris, P.E.
Company: Andrew and Kuske
FAX #: 343-9604
ADDRESS (GROUP)
9-3439604
RESULT
OK
E-2) BUSY
E-4) NO FACSIMILE CONNECTION
FAX COVER SHEET
DWQ Stormwater Project Number: SWS 001027
Project Name: Lowe's Foods Store
MESSAGE:
Dear Phil:
PAGE
P. 2/2
� Al
NCDENR
NCRTh CAROUNA 139FARTMEW of
ENVIRGNMENT AND MannAL RE5ouRCe s
Prom-, Linda Lewis
Water Quality Sect:
FA,X # 910-350-2
Phone # 9 39
- Stormwater
In order to keep the rtuioff in the trench, another baffle needs to be added to the outlet structure between the
24"pipes that enter from the trench and the 15" pipe that leads to the basin. Thds gill allow the trench system
to overflow into the basin, then overflow from the basin into the City street system. You can raise the top of the
bafF1P w711 ' rnn, P1Ptfa4';^" 'ill t^ " 1 —A ...,. '- "L -D"- - ' ' + � •• • ^ -
State of North Carolina
Department of Environment
and Natural Resources
Wilmington Regional Office
Janies It. Hunt, .1r., Governor
Bill Holman, Secretary
Division of Water Quality
Wilmington Regional Office
FAX COVER SHEET
NCDENR
NORTH CAROLINA DEPARTMENT OF
ENVIRONMENT AND NATURAL RESOURCES
Date: .January 3, 2001 No. of Pages: 2
To: Phil Norris, P.E. From: Linda Lewis
Company: Andrew and Kuske Water Quality Section - Stornnvater
FAX #: 343-9604 FAX # 910-350-2004
Phone # 910-395-3900
DWQ Stormwater Project Number: SW8 001027
Project Name: Lowe's Foods Store
M ESSAC E:
Dear Phil:
In order to keep the runoff in the trench, another baffle needs to be added to the outlet structure between the
24"pipes that enter front the trench and the 15" pipe that leads to the basin. This will allow the trench system
to overflow into the basin, then overflow front the basin into the City street system. You can raise the top of the
baffle wall front elevation 20 to 20.1 and make the top of the new baffle wall 20. Please see the attached detail.
Please report the individual lengths of perforated piping provided for each pipe diameter on the supplement.
l f the basin will not be included as part of the State approved system, the basin supplement will need to be deleted
from the application package, and you call disregard the C0111n1ent to Split LIP Section 111, ])art 6 of the application
into two columns.
The 11I'll lmum required volume to provide storage I -or, based on 1.5"of rain, is 19,805 cubic feet, using the volume
calculation method in the 13MP document. The volume available in the trench system alone is 18,389 cubic feet.
At a minimum, the system must be able to store 19,805 cubic feet, even if you demonstrate that the 25 year storm
can be handled. The storage requirement is a separate issue from the bypass requirenlcnt. If the basin will not be
used, you will need to increase the storage volume in the trench system..
Comment Numbers 1, 2, 5, 7, 8, 9 and 10 from the December 11, 2000, request for additional information letter,
are still valid requests.
Ifyou demonstrate that the 25 year, 24 hour storm call be infiltrated without discharging, then the requirenlcnt for
a vegetated filter can be waived. I"or any other storin events, a vegetated filter is required for the overflow from all
infiltration basins. (See .1008 (c) (4))
S:1WQS1S'1'ORM WA"I'IADI)INF01001027.JAN
127 Cardinal Dr. Gat., Wilmington, North Carolina 28405 Telephone 910-395-3900 FAX 910-350-2004
An Gqu:rl Opporlunity Affirmative Action Employer 50% recycled110%. post -consumer paper
PLAN
NOTE;
FR4 E AND GRATE TO BE STANDARD Cf Y
OF V&MINGTON CAST IRON FRAME AND GRATE
DEWEY BRAS. CH$N-M
V.
G vrly
5TI?slrr oavc. Coin
5156/1
BAFFLE WALL
INV, = m4.6e
Z0.1
d`r
V RCP
FOR BYPASS
To CITY
SYSTE M i
------
INV, = 1750
DROP INLET DETAIL
KS
24G PIPE f
INV. = 16.50
SECTION "A -A"
--15" PIPE
'Ta $A s ! N ��'e�l
,noV)
�I
q 24" PIPE
INV, = 16,56
(FRbM Trec-"if)
FRO 77F C
�- 2 X 2' FRAME & GRATE
TOP = 21.00
{
�I
r
. liffit #
CATCH BASIN/ovERFLO
,• Z� 4' x 6' PRECAST BOX
NOTEi 1
1
c
f
15" CCP OUTLET TO (JEASI N)
INFILTRATION AREA `
INV, = 1750
ELEV, = 16.00
6" CLASS 1 STONE
COMPACT SUBGRADE
Corporation Information
17ttp://corl).secst,ite.st,tte.nc.tis/cgi-bin/l istbycoi-p.pi
DEPARTMENT OF THE SECRETARY OF .STATE
CORPORATIONS
Data Current as of 02/01/00
Information for SOUTH PORT TRADING COMPANY, LLC
Corporation Id: 0467329 Date of Corporation: Aug 11 1998
Corporation Status: ACTIVL
................ -...
- — - ---
Duration: AUG 2048 Category: limited Liability Company
State of Incorporation: NC
—__
Country of Incorporation: UNI"I'1✓D STATES
Registered Agent Information
Registered Agent Name: I F' BLi-WIN
Address: 6314 OLFANDrR DRIVE ST1" A
City: WILMINGTON State: NC Zip: 28403
Filings
Return to exact name search
I�t',tlll'll Ifr CoI111f1e" se-m-ch
Notice: Information presented on this Web site is collected, maintained, and provided for the convenience of the
reader. While every effort is made 14) keep such information accurate and up-to-date, the Secretary of State does not
certify the authenticity of information herein that originates from third parties. The Secretary of State shall under no
circumstances be liable for any actions taken or omissions made from reliance on any information contained herein
from whatever source or any other consequences from any such reliance.
I of, 1 02/13/2001 2:39 I'M
Corporation Information
http://coi-p.ser,st,ite.state.nc.us/cgi-bin/listbycorp.pi
DEPARTMENT OF THE SECRETARY OF STATE
CORPORATIONS
Data Current as of 02/01/00
Information for SOUTHPORT TRADING COMPANY/PINE GROVE, LLC
Corporation Id: 0512467 Date of Corporation: Nov 18 1999
Corporation Status: ACTIVl;
.. .... ..
Duration: NOV 2049 Category: Limited Liability Company
FS
ate of Incorporation: NC
Country of Incorporation: UNITED S`I'AITS
Registered Agent Information
Registered Agent Name: CI-1R1ST01'I-IFIt M. CROUCH
Address: 6314 0LLANDER DRIVI
City: WILMING,fON State: NC Gip: 28403
Filings
Return to exact name search
Rclni•►► to soi►ildc.x sc,►rch
Notice: Information presented on this Web site is collected, maintained, and provided for the convenience of the
reader. While every effort is made to keep such information accurate and up-to-date, the Secretary of Slate does not
certify the authenticity of information herein that originates from third parties. The Secretary of State shall under no
circtnnslances he liable for any actions taken or omissions made from reliance on any information contained herein
from whatever source or any other consequences from any such reliance.
I of 1 02/13/2001 2:46 PM
Date
Design Andrew and Kuske
902 Market St. CONSULTING ENGINEERS. INC. Wilmi
Check Job I For
Pr A3 "L,)E D 0?- vrG
k)lC'm1"iG-C-0&D t1i 6-1
I
�Z H C
AL
1i + 1966 z
a, fttl� N
, N.C. 28401
Sheet
Job No.
4Fq 27 Z.
o/ 105101
RECEIVED
JAN 18 2001
nw
PRoa # ? c lv27
Date
Design
Andrew and Kuske
Sheet
�i} 3
�0
902 Market St. CON$UITING ENGINEERS, INC. Wilmington. N.C. 28401
pt 2
Check
Job
For (���,�� 1
Job No,
OTC,
5Tb 2n'I v�i r�fL �
Pr ��✓� r�-�J
y�j 2 Z
1 ,4 = ) %, (pLvCv 5� 0 2 4 30
�MeC-UivJ'f-� fir- 111,5) U Z-O SF ae_ 3-g02- A-e—'
22.) o 4-[i G oe.�-�-
�n
,C::l a-S T //
D 15 0/dw4C' 6 v O 1--t- 25 Ye7q-Q- -,-57r, 2�'J
PaS '7, 5 /n ��i X Y/-• ?G8 AG
x .j v - •Col Lo CAS
rocs I0 ---rj D "-) 6-'r 4.; Tom-, Tr-
o
70 2's -re_ 5 7 a 2er7 +
lr
Tit-
q I
LENcr7� a�
3t�'' Sec-T� o� : �'i)O ;7T o(opaCo ;77 Z) K �-T 3
2�" -no,J C�d Fl z - 3,0 FTz-) X
3�'� �►�� �o�P�� �i�- x loos � _ �; 1a3, � �=T;
2 P►P� 3 !wf (p �T� X jR4� = 1J LZSZ r3
V010 Pnd = 207-�Y' Fri �/� 850 i rT 2�, -7 -�74
97
Date
Design
Andrew and Kuske
SC-�
902 Market St. CONSULTING ENGINEERS. INC. Wilmington. N.C. 28401
f 2
Check
Job
For
Job No.
a�Z7
5Tmh/k-f E I ,J 0 lzl�- = �T" 3 C nJoT roc woE�
6 -sue b 2 PE-PT74 C EZ r 5 7-o f `7 5) r �✓ .5MM
ee ' X Po �� 17 Cog' fle��&-%j�
Z
Tvrn-l— 5�0,4,r c& e� ,oim-L = 21, 1:57 , 5�
2151 zl _3 , 4 �T 3
l n x (l ("0 6, 4Pzv F-Tz �- 2 �22� o4l&
21t 2�� FT Sr, -737,Fr
C,9_� _ -;; 67- %ice I nJ[ C ✓tit/9
g4S o•J �2A�e.4 m P2/�/T 6vTS �i'S1 Ear wr�-C p��G
/'VA
5o /&-) I� r' �715 Crd 2fv�
Data for 99272 LOWES FOODS REVISED Page 1
TEN YEAR 24-HOUR RAINFALL= 7.00 IN
Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC.
HydroCAD 5.01 000479 (c) 1986-1998 Applied Microcomputer Systems
SUBCATCHMENT 1 DRAINAGE AREA TO PIPE SYSTEM
PEAK= 23.61 CFS @ 12.13 HRS, VOLUME= 1.38 AF
ACRES CN SCS TR-20 METHOD
3.80 95 IMPERVIOUS SURFACE TYPE III 24-HOUR
.50 39 OPEN, SOIL GROUP A RAINFALL= 7.00 IN
4.30 88 SPAN= 11-15 HRS, dt=.02 HRS
Method Comment Tc min
DIRECT ENTRY Segment ID: 10.0
22
20
18
16
� 14
u 12
v
10
O 8
J
Li. 5
4
2
0m
SUBCATCHMENT I RUNOFF
DRAINAGE AREA TO PIPE SYSTEM
In 0 n m In
N vi M M
TIME Chours)
AREA= 4.3 AC
Tc= 10 MIN
CN= 88
SCS TR-20 METHOD
TYPE III 24-HOUR
RAINFALL= 7.00 IN
PEAK= 23.61 CFS
C' 12.13 HRS
VOLUME= 1.36 AF
m Ln w
V V In
Data for 99272 LOWES FOODS REVISED Page 2
TEN YEAR 24-HOUR RAINFALL= 7.00 IN
Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC.
HydroCAD_S.01 000479 _ (c)1986-1998 Applied Microcomputer Systems
REACH I
OUTLET TO ROADWAY
Qin = 0.00 CFS Q 0.00 HRS, VOLUME= 0.00 AF
Qout= 0.00 CFS Q 0.00 HRS, VOLUME= 0,00 AF, ATTEN= 0%, LAG= 0.0 MIN
DEPTH END
AREA
DISCH
(FT) (SO
-FT)
(CFS)
18" PIPE
0.0
0.0
0.00
.2
.1
.16
'n= .013
.3
.3
.65
LENGTH= 30 FT
.5
.4
1.45
SLOPE= .005 FT/FT
1.1
1.3
6.22
1.2
1.5
7.26
1.4
1.7
7.92
1.4
1.7
7.99
1.5
1.8
7.92
1.5
1.8
7.43
10
9
8
7
� 6
u
5
:3 4
O
-� 3
L�
2
1
0m
STOR-IND+TRANS METHOD
PEAK DEPTH= 0.00 FT
PEAK VELOCITY= 0.0 FPS
TRAVEL TIME = 0.0 M.IN
SPAN= 11-15 HRS, dt=.02 HRS
REACH I INFLOW & OUTFLOW
OUTLET TO ROADWAY
18'' PIPE
n=.013 L=30' 5=.005
STOR-IND+TRANS METHOD
VELOCITY= 0 FPS
TRAUEL= 0 MIN
Oin= 0.00 CFS
Qaut= 0.00 CFS
LAG= 0 MIN
in m in m in m Ln m
N N
TIME Chcur5)
Data for 99272 LOWES FOODS REVISED Page 3
TEN YEAR 24-HOUR RAINFALL= 7.00 IN
Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC.
HVdroCAD 5.01 000479 (c) 1986-1998 Applied_ Microcomputer Systems_
POND 1
EXFILTRATION TRENCH
Qin = 23.61 CFS @ 12.13 HRS, VOLUME= 1.38 AF
Qout= 10.33 CFS 0 12.38 HRS, VOLUME= 1.38 AF, ATTEN= 56%, LAG= 15.5 MIN
--Sb. Qpri= 0.00 CFS Q 0.00 HRS, VOLUME= 0.00 AF
Qsec= 10.33 CFS @ 12.38 HRS, VOLUME= 1.38 AF
Report reflects 52% open space
ELEVATION AREA INC.STOR CUM.STOR
(FT) _ (SF) (CF) (CF)_ _
16.0 5580 0 0
20.0 15345 21762 21762
STOR-IND METHOD
PEAK STORAGE = 15180 CF
PEAK ELEVATION= 18.8 FT
FLOOD ELEVATION= 20.0 FT
START ELEVATION= 16.0 FT
SPAN= 11-15 HRS, dt=.02 HRS
Tdet= 13.2 MIN (1-38 AF)
# ROUTE INVERT OUTLET DEVICES
1 P 19.5' 4' SHARP -CRESTED RECTANGULAR WEIR
Q=C L H-1.5 C=3.27+.4 H/4 L=Length-2(.1 H)
2 S 0.0' EXFILTRATION
V= .05 FPM over SURFACE AREA
Primary Discharge
I 1=Sharp-Crested Rectangular Weir
Secondary Discharge
I2=Exfiltration
POND 1 INFLOW & OUTFLDW
EXFILTRATION TRENCH
22 STOR-IND METHOD
20 PEAK STOR= 15180 CF
18 PEAK ELEO= 18.8 FT
r 16 Din_ 23.61 CFS
0 Gout= 10.33 CF5
u 14 0Pri= 0.20 CF5
12 Qsec= 10.33 CFS
13 10 ` LAG= 15.5 MIN
CD
LL 6 %
z
e
N N r`1 r*7 v Q N
TIME Choirs)
Data for 99272 LOWES FOODS REVISED Page 4
TEN YEAR 24-HOUR RAINFALL= 7.00 IN
Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC.
HydroCAD 5.01 000479 (c) 1986-19.98 Applied Microcomputer Systems
POND 2
OPEN EXFILTRATION POND
Qin =
0.00
CFS @
0.00
HRS,
VOLUME= 0.00
AF
Qout=
0.00
CFS @
0.00
HRS,
VOLUME= 0.00
AF,
ATTEN= 0%, LAG=
0.0 MIN
Qpri=
0.00
CFS @
0.00
HRS,
VOLUME= 0.00
AF
Qsec=
0.00
CFS @
0.00
HRS,
VOLUME= 0.00
AF
ELEVATION
AREA
INC.STOR
CUM.STOR
STOR-IND METHOD
(FT)
(SF)
(CF)
(CF)
PEAK STORAGE =
0
CF
17.5
1160
0
0
PEAK ELEVATION=
17.5
FT
18.5
1700
1430
1430
FLOOD ELEVATION=
19.5
FT
19.5
2320
2010
3440
START ELEVATION=
17.5
FT
SPAN= 11-15 HRS, dt=.02 HRS
#(_ RO_UTE INVERT OUTLET_ DEVICES
1 S 0.0' EXFILTRATION - - -
V= .05 FPM over SURFACE AREA
2 P 18.5' 12, SHARP -CRESTED RECTANGULAR WEIR
Q=C L H-1.5 C=3.27+.4 H/3 L=Length-0(.1 H)
Primary Discharge
� 2=Sharp-Crested Rectangular Weir
Secondary Discharge
� I=Exfiltration
10
9
8
6
U
5
3 q
O
� 3
2
1
0m
POND 2 INFLOW! & OUTFLOIJ
OPEN EXFILTRATION POND
STDR-IND METHOD
PEAK STDR= 0 CF
PEAK ELEV= 17.5 FT
Qin= 0.00 CF5
Oout= 0.00 CFS
Opri= 0.00 CFS
Qsec- 0.00 CFS
LAG= 0 MIN
Ln m n m Ln m Ln m
N N M P7 V V Ln
TIME (hours)
Data for 99272 LOWES FOODS REVISED Page 5
25 YEAR 24-HOUR RAINFALL= 8.00 IN
Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC.
HvdroCAD 5.01 000479 (c) 1986-1998 Applied Microcomputer Svstems
SUBCATCHMENT 1 DRAINAGE AREA TO PIPE SYSTEM
PEAK= 27.48 CFS @ 12.12 HRS, VOLUME= 1.61 AF
ACRES CN SCS TR-20 METHOD
3.80 95 IMPERVIOUS SURFACE TYPE III 24-HOUR
.50 39 OPEN, SOIL GROUP A RAINFALL= 8.00 IN
4.30 88 SPAN= 11-15 HRS, dt=.02 HRS
Method Comment _ T Tc Amin]
DIRECT ENTRY Segment ID: 10.0
26
24
22
20
kO 18
L.- 16
U
14
3 12
O 10
B
61
2
Om
SUBCATCHMENT 1 RUNOFF
DRAINAGE AREA TO PIPE SYSTEM
L, m n CD Ln
N N M M
TIME (hours)
AREA= 4.3 AC
Tc= 10 MIN
CN= 8B
SCS TR-20 METHOD
TYPE III 24-HOUR
RAINFALL= 6.03 IN
PEAK= 27.46 CF5
C 12.12 HRS
VOLUME= 1.61 AF
m L, m
V V Ln
Data for 99272 LOWES FOODS REVISED Page 6
25 YEAR 24-HOUR RAINFALL= 8.00 IN
Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC.
HydroCAD 5_.01 000479 (c)_ 1986-19.98 Applied-MicrocomputerSystems
REACH 1
OUTLET TO ROADWAY
Qin = 0.00 CFS Q 0.00 HRS, VOLUME= 0.00 AF
Qout= 0.00 CFS @ 0.00 HRS, VOLUME= 0.00 AF, ATTEN= 00, LAG= 0.0 MIN
DEPTH END
AREA
DISCH
(FT) (SQ-FT)
(CFS)_
0.0
0.0
0.00
.2
.1
.16
.3
.3
.65
.5
.4
1.45
1.1
1.3
6.22
1.2
1.5
7.26
1.4
1.7
7.92
1.4
1.7
7.99
1.5
1.8
7.92
1.5
1.8
7.43
10
9
B
7
r-,
c- 6
U
5
3 q
O
`j 3
LL-
1
0�
18" PIPE
n= .013
LENGTH= 30 FT
SLOPE= .005 FT/FT
STOR-IND+TRANS METHOD
PEAK DEPTH= 0.00 FT
PEAK VELOCITY= 0.0 FPS
TRAVEL TIME = 0.0 MIN
SPAN= 11-15 HRS, dt=.02 HRS
REACH I INFLOW & OUTFLOW
OUTLET TO ROADWAY
18'' PIPE
n=.013 L=30' 5=.005
STOR-IND+TRANS METHOD
UELOCITY= 0 FPS
TRAVEL= 0 MIN
O�n= 3 20 CFS
Gout= 0.00 CF5
LAG= 0 MIN
Ln m u, m Ln m in m
-- N N f'l r'"1 v v !n
TIME (hour5)
Data for 99272 LOWES FOODS REVISED Page 7
25 YEAR 24-HOUR RAINFALL= 8.00 IN
Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC.
HydroCAD 5.01_ 000479 (c) 1986-1998 Applied Microcomputer Systems
POND 1
EXFILTRATION TRENCH
Qin =
27.48
CFS
G
12.12
HRS, VOLUbIE=
1.61
AF
Qout=
11.71
CFS
@
12.39
HRS, VOLUZIE=
1.61
AF, ATTEN= 57%�, LAG= 15.9 MIN
Qpri=
0,00
CFS
9
0.00
HRS, VOLU1`EE=
0.00
AF
Qsec=
11.71
CFS
@
12.39
HRS, VOLUI`IE=
1.61
AF
Report
reflects
52% open space
ELEVATION AREA INC.STOR CUM.STOR
FT SF CF CF
16.0 5580 0 0
20.0 15345 21762 21762
STOR-IND METHOD
PEAK STORAGE = 18885 CF
PEAK ELEVATION= 19.5 FT
FLOOD ELEVATION= 20.0 FT
START ELEVATION= 16.0 FT
SPAN= 11-15 HRS, dt=.02 HRS
Tdet= 15.2 MIN (1.6 AF)
-4L_R_OUTE INVERT _ OUTLET DEVICES _
1 P 19.5' 4' SHARP -CRESTED RECTANGULAR WEIR
Q=C L H^1.5 C=3.27+.4 H/4 L=Length-2(.1 H)
2 S 0.0' EXFILTRATION
V= .05 FPM over SURFACE AREA
Primary Discharge
I 1=Sharp-Crested Rectangular weir
Secondary Discharge
� 2=Exfiltration
kn
U
3
0
LL
26
24
22
20
18
16
14
12
10
8
6
4
2,
6.10
POND I INFLOW & OUTFLOW
EXFILTRATION TRENCH
STOR-IND METHOD
PEAK STCR= 18685 CF
PEAK ELEV= 19.5 FT
Oin= 27.49 CFS
Ooui= 11.71 CFS
Opri= 0.03 CFS
Qsec= 11,71 CFS
LAG= 15.9 MIN
1
m in - m Ln m
TT- Lg (hours)
Data for 99272 LOWES FOODS REVISED Page 8
25 YEAR 24-HOUR RAINFALL= 8.00 IN
Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC.
HVdroCAD 5.01 000479 (c) 1986-1998 Applied Microcomputer Systems
POND 2
OPEN EXFILTRATION POND
a
Qin = 0.00
CFS fl
0.00
HRS,
VOLUME= 0.00
AF
Qout= 0.00
CFS @
0.00
HRS,
VOLUME= 0.00
AF,
ATTEN= 0%, LAG=
0.0 MIN
Qpri= 0.00
CFS @
0.00
HRS,
VOLUME= 0.00
AF
Qsec= 0.00
CFS p
0.00
HRS,
VOLUME= 0.00
AF
ELEVATION
AREA
INC.STOR
CUM.STOR
STOR-IND METHOD
(FT)
(SF)
(CF)
(CF)
PEAK STORAGE =
0
CP
17.5
1160
0
0
PEAK ELEVATION=
17.5
FT
18.5
1700
1430
1430
FLOOD ELEVATION=
19.5
FT
19.5
2320
2010
3440
START ELEVATION=
17.5
FT
SPAN= 11-15 HRS, dt=.02 HRS
# ROUTE INVERT OUTLET DEVICES
1 S 0.0' EXFILTRATION -
V= .05 FPM over SURFACE AREA
2 P 18.5' 12, SHARP -CRESTED RECTANGULAR WEIR
Q=C L H-1.5 C=3.27f.4 H/3 L=Length-0(.1 H)
Primary Discharge
12=Sharp-Crested Rectangular weir
Secondary Discharge
11=Exfiltration
POND 2 INFLOW & OUTFLOW
OPEN EXFILTRATION POND
STOR-IND METHOD
PEAK STOR= 0 CF
PEAK ELEV= 17 5 FT
Din= 0.20 CFS
Oout= 2.00 CFS
Qpr- � = 0.03 CFS
Osec= 0.02 CFS
LAG= 0 MIN
0 m cn m un m in m
N N rry r') v v in
TIME (hours)
Data for 99272 LOWES FOODS REVISED Page 9
50 YEAR 24-HOUR RAINFALL= 9.00 IN
Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC.
HydroCAD_5._01 000479_ LZ 1986-1998 Applied Microcomputer Systems_
SUBCATCHMENT 1 DRAINAGE AREA TO PIPE SYSTEM
PEAK= 31.34 CFS @ 12.12 HRS, VOLUME= 1.84 AF
ACRES CN SCS TR-20 METHOD
3.80 95 IMPERVIOUS SURFACE TYPE III 24-HOUR
.50 39 OPEN, SOIL GROUP A RAINFALL= 9.00 IN
4.30 88 SPAN= 11-15 HRS, dt=.02 HRS
Method _ _ - Comment Tc (min)
DIRECT ENTRY Segment ID: 10.0
30
28
26
24
22
20
`Y 18
16
14
0 12
J 10
LL e
6
4
2
BL
SUSCATCHMENT 1 RUNOFF
DRAINAGE AREA TO PIPE SYSTEM
Ul m N Co Ln
N N r"7 M
TIME (hours)
AREA= 4.3 AC
Tc= 10 MIN
CN= 88
SCS TR-20 METHOD
TYPE III 24-HOUR
RAINFALL= 9.B0 IN
PEAK= 31.34 CFS
2 12.12 HRS
UOLUME= 1.84 AF
m
V V Ln
Data for 99272 LOWES FOODS REVISED Page 10
50 YEAR 24-HOUR RAINFALL= 9.00 IN
Prepared by ANDREW L KUSKE CONSULTING ENGINEERS, INC.
HydroCAD 501 000479_ (c) 1986-1998 Applied Microcomputer Systems
REACH 1
OUTLET TO ROADWAY
Qin = 0.00 CFS Q 0.00 HRS, VOLUME= 0.00 AF
Qout= 0.00 CFS @ 0.00 HRS, VOLUME= 0.00 AF, ATTEN= 0%, LAG= 0.0 MIN
DEPTH END
AREA
DISCH
(FT) (SO
-FT)
(CFS)
0.0
0.0
0.00
.2
.1
.16
.3
.3
.65
.5
.4
1.45
1.1
1.3
6.22
1.2
1.5
7.26
1.4
1.7
7.92
1.4
1.7
7.99
1.5
1.8
7.92
1.5
1.8
7.43
181, PIPE
n= .013
LENGTH= 30 FT
SLOPE= .005 FT/FT
STOR-IND+TRANS METHOD
PEAK DEPTH= 0.00 FT
PEAK VELOCITY= 0.0 FPS
TRAVEL TIME = 0.0 MIN
SPAN= 11-15 HRS, dt=.02 HRS
REACH I INFLOW & OUTFLOW
OUTLET TO ROADWAY
18" PIPE
n= 213 L=30' 5=.005
STDR-IND+TRANS METHDD
VELDCITY= 0 FPS
TRAVEL= 0 MIN
Din= 0.00 CFS
Oout= 0.00 CF5
LAG= 0 MIN
Ln Ln m n co L CD
N N
TIME (hours)
Data for 99272 LOWES FOODS REVISED Page ii
50 YEAR 24-HOUR RAINFALL= 9.00 IN
Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC.
EvdroCAD 5.01 000479 (c)_1986-1998 Applied Microcomputer Systems _
POND 1
EXFILTRATION TRENCH
Qin = 31.34 CFS p 12.12 HRS, VOLUME= 1.84 AF
Qout= 16.16 CFS 9 12.32 HRS, VOLUME= 1.83 AF, ATTEN= 48%, LAG= 12.0 MIN
Qpri= 3.54 CFS @ 12.32 HRS, VOLUME= 06 AF
Qsec= 12.62 CFS @ 12.32 HRS, VOLUME= 1.77 AF
Report reflects 52% open space
ELEVATION AREA INC.STOR CUM.STOR
(FT) (SF) _ (CF) (CF)
16.0 5580 0 0
20.0 15345 21762 21762
STOR-IND METHOD
PEAK STORAGE = 21323 CF
PEAK ELEVATION= 19.9 FT
FLOOD ELEVATION= 20.0 FT
START ELEVATION= 16.0 FT
SPAN= 11-15 HRS, dt=.02 HRS
Tdet= 15.7 MIN (1.82 AF)
# ROUTE INVERT OUTLET DEVICES
1 P 19.5' 4' SHARP -CRESTED RECTANGULAR WEIR
Q=C L H-1.5 C=3.27+.4 H/4 L=Length-2(.1 H)
2 S 0.0' EXFILTRATION
V= .05 FPM over SURFACE AREA
Primary Discharge
11=Sharp-Crested Rectangular Weir
Secondary Discharge
L---2=Exfiltration
POND 1 INFLOW & OUTFLOW
EXFILTRPTION TRENCH
30
26
STOR-IND METHOD
26
PEAK STOR= 21323 CF
24
PEAK ELEV= 19.9 FT
22
OIn= 31.34 CF5
20
Oout= 16.16 CFS
18
U
Opr1= 3.54 CF5
16
r Osec= 12 62 CF5
1 2
! ` LAG= 12 MIN
fr .=
LL
B
�
\
4
2
'
0m
(n m in m in m Ln m
r) un
TIME (hours)
Data for 99272 LOWES FOODS REVISED Page 12
50 YEAR 24-HOUR RAINFALL= 9.00 IN
Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC.
H droCAD 5.01 000479 c 1986-1998 Applied Microcom user Systems
POND 2
OPEN EXFILTRATION POND
Qin = 3.54 CFS Q 12.32 HRS, VOLUME= .06 AF
Qout= 1.39 CFS @ 12.47 HRS, VOLUME= .06 AF,
Qpri= 0.00 CFS 0 0.00 HRS, VOLUME= 0.00 AF
Qsec= 1.39 CFS 9 12.47 HRS, VOLUME= 06 AF
ELEVATION AREA INC.STOR CUM.STOR
(FT) (SP) (CF) (CF)
17.5 1160 0 0
18.5 1700 1430 1430
19.5 2320 2010 3440
ATTEN= 61$, LAG= 8.7 MIN
STOR-IND METHOD
PEAK STORAGE = 1354 CF
PEAK ELEVATION= 18.4 FT
FLOOD ELEVATION= 19.5 FT
START ELEVATION= 1-1.5 FT
SPAN= 11-15 HRS, dt=.02 HRS
Tdet= 10.6 MIN (.06 AF)
# ROUTE INVERT OUTLET DEVICES
1 S 0.0' EXFILTRATION
V= .05 FPM over SURFACE AREA
2 P 18.5' 12, SHARP -CRESTED RECTANGULAR WEIR
Q=C L H^1.5 C=3.27+.4 H/3 L=Length-O(.1 H)
Primary Discharge
12=Sharp-Crested Rectangular Weir
Secondary Discharge
I I=Exfiltration
3.4
3.2
3.0
2.8
2.6
2.4
2.2
u 2.0
v I.B
1.6
(:D 1 .4
J 1.2
IL 1 .0
.8
.6
.4
.2
0.0m
POND 2 INFLOW 8 OUTFLOW
OPEN EXFILTRATION POND
STOR-IND METHOD
PEAK $TOR= 1354 CF
PEAK ELEu= 18.4 FT
4
In m N m In
TIME (hours)
Qin= 3.54 CF5-
Oout= 1,39 CF5
Opri= 0.00 CF5
Qsec= 1.39 CFS
LAG= 8.7 MIN
IT v In
Andrew &Kuske John R. Andrew, P.E,
CONSULTING ENGINEERS, INC. J.A. Kuske, P.E.
J. Phillip Norris, P.E.
902 Market St. • Wilmington, North Carolina 28401 A733 • Telephone 910/343-9653 • Fox 910/343-9604 + okengnrs®wilmington.net
October 16, 2000
Ms. Linda Lewis
NC DENR
Division of Water Quality
127 Cardinal Drive Extension
Wilmington, NC 28405-3845
Re: Lowe's Foods — Pine Grove Road
New Hanover County
State Stormwater Permit Submittal
A&K Project No. 99272
Dear Ms. Lewis:
Enclosed are two sets of plans for the subject project, one set of calculations,
the original Division of Water Quality stormwater management permit
application, and one copy, one copy of the SWU-103 and SWU-107 supplement
forms, one copy of the stormwater narrative and a $420.00 check for the
processing fee.
Please review this information for approval and contact us with any questions or
comments you may have. Thank you for your assistance on this project.
Sincerely,
ANDREW & KUSKE
CONSU ENGINEERS, I C.
illip Norris, P. E.
99272-101600swi
Enclosures
CC" Nick Garrett, Jr.
STORMWATER SYSTEM NARRATIVE
LOWE'S FOODS
PINE GROVE ROAD
NEW HANOVER COUNTY, NORTH CAROLINA
For
Southport Trading Co.
PO Box 4893
Wilmington, NC 28406
,l1111110" y
N CAR
AL
11966
• 0
''�11AIt111111ta�t
October, 2000
Prepared by:
RECEIVED
OCT 2-4 2000
DWQ
PROM # S U) FOC) k o zq
ANDREW & KUSKE CONSULTING ENGINEERS, INC.
902 Market Street
Wilmington, North Carolina 28401
910/343-9653
910/343-9604 — Fax
www.andrewandkuske.com
A & K #99272
3
NARRATIVE
STORMWATER MANAGEMENT
The project site is located in New Hanover County at the corner of Greenville
Loop Road and Pine Grove Road. Land disturbing on the site will exceed one acre,
which requires the site to comply with the Stake Regulations. The stormwater runoff
from the development will be directed to an infiltration stormwater system. The
stormwater system was designed to accommodate this site at 88.25% impervious area
lot coverage and a minimum of 1.5 inches infiltration as the site drains to SA waters.
The system is designed to allow no discharge in rainfall events up to the 25-year storm.
K