Loading...
HomeMy WebLinkAboutSW8001027_HISTORICAL FILE_20001211STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW�fIIIIDQ I DOC TYPE El CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE /;2�� YYYYMMDD State of North Carolina Department of Environment and Na-t rill Resourees Wilmington Regional Office Jarnes B. 7Tunt, Jr., Governor Bill Holman, Secretary Division ofwntcr Quality December 11, 2000 Mr. Nick Garrett, Jr., Managing Mamber Southport Trading Co. PO Box_48 i3 Wilmington, NC 28406 Subject: REQUEST FOR ADDITIONAL INFORMATION Stormwater Project No. S W 8 001027 Lowe's Foods Pine Grove Drive Site New'Hanover County Dear Mr. Garrett: The Wilmington Regional Office received a Stormwater Management Permit Application for Lowe's Foods Pine Grove Drive Site on October 24, 2000. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: Delineate all wetlands on site, disturbed or undisturbed, or note on the plans that none exist 2. Is Southport Trading Company an LLC? Please indicate what kind of company it is .on the application. 3. :Since: two�supple,ments.have•be'en"pr'ovi'ded, there must beat least.two columns filled in.on the -application, one for the trench and.one for,the'basin. There'is no symbol in -the legend and no note-on.the plans to indicate that.a•trench is provided, anywhere. 4. Is the flat grade piping -supposed to be the proposed trench system? The current design seems to use the flat grade perforated piping as the primary treatment, with any overflows going into .the basin. You;cawhave both the treneb:and the•basin, but each one must -be a separate system, .sized individually -to accommodate it's separate drainage area. The outlet and overflow must also be.separate. ,The,trenchesshould.overflow.to.a�vegetated filter instead of the basinAf.you'keep ,the current:setup,"the basin will.need.tobe sized for the entire drainage:area,"as'if the,trenches -weren't there, -just`like,two ponds in series. The last system7in line has to:be sized for.everything. I cannot verify calculations until this'is resolved. 4. Please provide an infiltration basin detail on the plans. Include the 3:1 side slopes, and note the bottom and storage elevations. S. Please add.a detail of the.required vegetated filter to the plans. 6. A large portion of the perimeter collection piping is:laid at a flat grade. •How .will,this work in regards to directing runoff into the'infiltration basin for treatment? Is -this piping part of the unlabeled proposed trench? If -so, please.label. I-wi11 consult with Raleigh -regarding the flat grade of the proposed collection system. If you separate the trench and basin systems, the flat grade will be OK. 127 Cardinal Dr. Ext., Wilmington, North Carolina 28405 Telephone 910-395-3901) FAX 910-350-2004 An Equal Opportunity Affirmative Action Employsr 50'% recycledl10% post -consumer paper Mr. Garrett December 11, 2000 Stornwater Project No. SW8 001027 7. The intersection of Oleander Drive and South College needs to be added to the vicinity map. The rules require the nearest major intersection be shown. Please provide existing grades at Sycamore Hollow to demonstrate that no offsite runoff from this site enters the proposed basin. There is no existing ditch between the two properties, so the possibility of offsite runoff does exist. 9. Based on the grading shown at Sycamore Hollow, a low area will be formed behind Units 313 and 4A, with no proposed outlet for the runoff that will accumulate. Please address. 10. Please specify the stone to be used in the trench, and provide it's specification sheet. A void ratio of 0.55 is definitely not normal, which is around 0.4. Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to January 11, 2001, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a,completed.appliication to issue the permit. The -construction of any impervious: surfaces, other.than a construction entrance under:an.approved Sedimentation Erosion •ControlTlan, is a violation ofNCGS 143-215.1 and.is subjectao enforcement action pursuant to NCGS -143-21.5,6A. }Tease reference the -State assigned project number on all correspondence. Any original documents that need to be revised have been sent to the engineer or agent. All original documents must be returned or.new originals must be provided. ,Copies are not acceptable. -If you have any questions concerning this matter please .feel free -to call me.at:(91.0) 395-3900. Sincerely, �cj,at, odw,-� Linda Lewis Environmental Engineer RSS/arl: S:IWQSISTORMWATIADDINFO\001027.DEC cc: Linda Lewis Phil Non -is, 127 Cardinal Dr..Ext., Wilmington, North Carolina 28405 'telephone 910-395-3900 FAX 910-350-2004 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper A5 ��� NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director March 29, 2011 Mr. Nick Garrett, Jr., Managing Member Southport Trading Company, LLC P. O. Box 4893 Wilmington, NC 28406 Subject: Permit Extension, Session Laws 2009-406 and 2010-177 Stormwater Permit #SW8 001027 High Density — Lowe's Food — Pine Grove New Hanover County Dear Mr. Garrett: Dee Freeman Secretary On August 5, 2009, the Governor signed Session Law 2009-406. This law impacts any development approval issued by the Division of Water Quality under Article 21 of Chapter 143 of the General Statutes, which is -current and valid at any point between January 1, 2008, and December 31, 2010. The law extends the effective period of any stormwater permit that is set to expire during this time frame to three (3) years from its current expiration date. On August 2, 2010, the Governor signed Session Law 2010- 177 which grants an extra year for a total of four (4) years extension. Accordingly, Stormwater Permit # SW8 001027 which has already expired on February 13, 2011, is now in effect until February 13, 2015. Please resubmit the renewal application and fee. at least 180 days prior to February 13, 2015, which would be August 13, 2014. A copy of the Renewal Application can be obtained from the following website: httpalportal.ncdenr.org/web/wq/ws/su/statesw/forms—docs, If you have any questions, please contact the Division of Water Quality in the Wilmington Regional Office at 910-796-7215. Sincerely, Georgette Scott Stormwater Supervisor Division of Water Quality S:WQSISTORMWATERIRENEWALSISL2009-406 2010-177\001027.marl 1 cc: Wilmington Regional Office Wilmington Regional office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 One Phone: 910-796-72151 FAX:910-350-2t)04 4 Customer Service: 1-877.623-6748 NorthCarolina interne[: wvuw.ncwaterquaiity.org ,/ An Equal Opportunity l Affirmative Action Employer V trtunT J =CJPh � NC®ENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor I Director February 23, 2010 Mr. Nick Garrett, Jr., Managing Member Southport Trading Company, LLC P. O. Box 4893 Wilmington, NC 28406 Subject: PERMIT RENEWAL REQUEST Stormwater Permit No. SW8 001027 Lowe's Foods -Pine Grove Drive New Hanover County Dear Mr, Garrett: Dee Freeman Secretary The Division of Water Quality issued a Coastal Stormwater Management Permit, Number SW8 001027 to Lowe's Foods — Pine Grove Drive for a High Density Project on February 13, 2001. This permit expires on February 13, 2011. Per 15A NCAC 2H.1003(h) (the stormwater rules), applications for permit renewals shall be submitted 180 days prior to the expiration of a permit and must be accompanied by a processing fee, which is currently set at $505.00. If this is still an active project please complete and submit the enclosed renewal application prior to August 13, 2010. If this project has not been constructed and a permit is no longer needed, please submit a request to have the permit -escinded. If you have sold the project, or are no longer the permittee, please provide the name, mailing address and phone number of the person or entity that is now responsible for this permit. Enclosed is a form for change of ownership, which should be completed and submitted if the property has changed hands. Your permit requires that upon completion of construction and prior to operation of the permitted stormwater treatment system, a certification of completion be submitted to the Division from an.appropriate designer for the type of system installed. This is to certify that the permitted facility has been installed in accordance with the permit, the approved plans, specifications and supporting documentation. Please include a copy of the certification with your permit renewal request and processing fee. Enclosed is a copy of a sample certification. Also enclosed is a new Operation and Maintenance agreement that should be completed and submitted along with your renewal application. You should be aware that failure to provide the Designer's Certification and the operation of a stormwater treatment facility without a valid permit, are violations of NC General Statute 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $10,000 per day. If you have any questions, please feel free to contact David Cox at 910-796-7318. Sincerely, Georgette Scott, Stormwater Supervisor Surface Water Protection Section Wilmington Regional Office Enclosures GDSldwc S:\WQS\Stormwater\Renewal\Reques ts\2001\001027.febl0 cc: Wilmington Regional Office File Wilmington Regional Office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 One Phone: 910-796-72151 FAx 910-350-20041 Customer Service: 1-877-623-6746 NorthCarolina Intemei: www.ncwaterquality.org Ar Equal Opportunity 1 Affirmative Action Employer � ������ — Andrew & Kuske — — = CONSULTING ENGINEERS, INC. John R. Andrew, RE, J. A. Kuske, P.E. J. Phillip Norris, P.E. 902 Market St. • Wilmington, North Carolina 28401-4733 • Telephone 910/343-9653 • Fax 910/343-9604 • www.andrewandkuske.com January 5, 2001 Ms. Linda Lewis NCDENR1Div. of Environmental Mgmt. 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Re: Lowes Foods Pine Grove Drive Site SW8 001027 New Hanover County Additional Information A&K No. 99272 Dear Ms. Lewis: JAN 18 2001 We are responding to your letter of December 11, 2000 and subsequent fax of January 3, 2001 as follows: 1. It has been noted on the plans that no wetlands exist on the site. 2. Southport Trading Company is a LLC. 3. As we discussed, the 1.5-inch storage will be provided entirely in the trench system. The trench system has been classified on the plans. 4. As previously discussed, the trench system will contain the 1.5-inch storage requirements. 4a. The infiltration basin is for City of Wilmington storage requirements only. 5. Due to the system capability to contain the 25-year, 24-hour storm, no vegetated filter is required. 6. As previously discussed, the infiltration basin is not part of the state system. 7. The vicinity map has been modified per your request. Ms. Linda Lewis January 5, 2001 Page 2 8. A swale has been added to eliminate the possibility of off -site water from entering the basin. 9. The swale noted in item 8 above will allow drainage of this area. 10. The void ratio will be 0.4 for the stone. The total trench void ratio is now 51.7%. As indicated in your memo of January 3 we have added another baffle wall in the outlet structure to separate the trench system from the basin system. We are enclosing 2 sets of revised plans and calculations for your review and approval. Please let us know if you need any additional information. Sincerely, ANDREW & KUSKE CONSULTING -ENGINEERS, IN 4 !/i' hillip rris, P.E. Pete Avery Enclosures 99272-1-O5-01 ftr '4 * * * COMMUNICATION RESULT REPORT ( JAN. 3.2001 10:41AM ) P. 1 FILE MODE OPTION T002 MEMORY TX ------------------------------------ REASON FOR ERROR E-1) HANG UP OR LINE FAIL E-3) NO ANSWER State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office James B. Aunt, Jr., Governor Bill Holman, Secretary Division of Water Quality Wilmington Regional Office Date: January 3, 2001 To: Phil Norris, P.E. Company: Andrew and Kuske FAX #: 343-9604 ADDRESS (GROUP) 9-3439604 RESULT OK E-2) BUSY E-4) NO FACSIMILE CONNECTION FAX COVER SHEET DWQ Stormwater Project Number: SWS 001027 Project Name: Lowe's Foods Store MESSAGE: Dear Phil: PAGE P. 2/2 � Al NCDENR NCRTh CAROUNA 139FARTMEW of ENVIRGNMENT AND MannAL RE5ouRCe s Prom-, Linda Lewis Water Quality Sect: FA,X # 910-350-2 Phone # 9 39 - Stormwater In order to keep the rtuioff in the trench, another baffle needs to be added to the outlet structure between the 24"pipes that enter from the trench and the 15" pipe that leads to the basin. Thds gill allow the trench system to overflow into the basin, then overflow from the basin into the City street system. You can raise the top of the bafF1P w711 ' rnn, P1Ptfa4';^" 'ill t^ " 1 —A ...,. '- "L -D"- - ' ' + � •• • ^ - State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Janies It. Hunt, .1r., Governor Bill Holman, Secretary Division of Water Quality Wilmington Regional Office FAX COVER SHEET NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Date: .January 3, 2001 No. of Pages: 2 To: Phil Norris, P.E. From: Linda Lewis Company: Andrew and Kuske Water Quality Section - Stornnvater FAX #: 343-9604 FAX # 910-350-2004 Phone # 910-395-3900 DWQ Stormwater Project Number: SW8 001027 Project Name: Lowe's Foods Store M ESSAC E: Dear Phil: In order to keep the runoff in the trench, another baffle needs to be added to the outlet structure between the 24"pipes that enter front the trench and the 15" pipe that leads to the basin. This will allow the trench system to overflow into the basin, then overflow front the basin into the City street system. You can raise the top of the baffle wall front elevation 20 to 20.1 and make the top of the new baffle wall 20. Please see the attached detail. Please report the individual lengths of perforated piping provided for each pipe diameter on the supplement. l f the basin will not be included as part of the State approved system, the basin supplement will need to be deleted from the application package, and you call disregard the C0111n1ent to Split LIP Section 111, ])art 6 of the application into two columns. The 11I'll lmum required volume to provide storage I -or, based on 1.5"of rain, is 19,805 cubic feet, using the volume calculation method in the 13MP document. The volume available in the trench system alone is 18,389 cubic feet. At a minimum, the system must be able to store 19,805 cubic feet, even if you demonstrate that the 25 year storm can be handled. The storage requirement is a separate issue from the bypass requirenlcnt. If the basin will not be used, you will need to increase the storage volume in the trench system.. Comment Numbers 1, 2, 5, 7, 8, 9 and 10 from the December 11, 2000, request for additional information letter, are still valid requests. Ifyou demonstrate that the 25 year, 24 hour storm call be infiltrated without discharging, then the requirenlcnt for a vegetated filter can be waived. I"or any other storin events, a vegetated filter is required for the overflow from all infiltration basins. (See .1008 (c) (4)) S:1WQS1S'1'ORM WA"I'IADI)INF01001027.JAN 127 Cardinal Dr. Gat., Wilmington, North Carolina 28405 Telephone 910-395-3900 FAX 910-350-2004 An Gqu:rl Opporlunity Affirmative Action Employer 50% recycled110%. post -consumer paper PLAN NOTE; FR4 E AND GRATE TO BE STANDARD Cf Y OF V&MINGTON CAST IRON FRAME AND GRATE DEWEY BRAS. CH$N-M V. G vrly 5TI?slrr oavc. Coin 5156/1 BAFFLE WALL INV, = m4.6e Z0.1 d`r V RCP FOR BYPASS To CITY SYSTE M i ------ INV, = 1750 DROP INLET DETAIL KS 24G PIPE f INV. = 16.50 SECTION "A -A" --15" PIPE 'Ta $A s ! N ��'e�l ,noV) �I q 24" PIPE INV, = 16,56 (FRbM Trec-"if) FRO 77F C �- 2 X 2' FRAME & GRATE TOP = 21.00 { �I r . liffit # CATCH BASIN/ovERFLO ,• Z� 4' x 6' PRECAST BOX NOTEi 1 1 c f 15" CCP OUTLET TO (JEASI N) INFILTRATION AREA ` INV, = 1750 ELEV, = 16.00 6" CLASS 1 STONE COMPACT SUBGRADE Corporation Information 17ttp://corl).secst,ite.st,tte.nc.tis/cgi-bin/l istbycoi-p.pi DEPARTMENT OF THE SECRETARY OF .STATE CORPORATIONS Data Current as of 02/01/00 Information for SOUTH PORT TRADING COMPANY, LLC Corporation Id: 0467329 Date of Corporation: Aug 11 1998 Corporation Status: ACTIVL ................ -... - — - --- Duration: AUG 2048 Category: limited Liability Company State of Incorporation: NC —__ Country of Incorporation: UNI"I'1✓D STATES Registered Agent Information Registered Agent Name: I F' BLi-WIN Address: 6314 OLFANDrR DRIVE ST1" A City: WILMINGTON State: NC Zip: 28403 Filings Return to exact name search I�t',tlll'll Ifr CoI111f1e" se-m-ch Notice: Information presented on this Web site is collected, maintained, and provided for the convenience of the reader. While every effort is made 14) keep such information accurate and up-to-date, the Secretary of State does not certify the authenticity of information herein that originates from third parties. The Secretary of State shall under no circumstances be liable for any actions taken or omissions made from reliance on any information contained herein from whatever source or any other consequences from any such reliance. I of, 1 02/13/2001 2:39 I'M Corporation Information http://coi-p.ser,st,ite.state.nc.us/cgi-bin/listbycorp.pi DEPARTMENT OF THE SECRETARY OF STATE CORPORATIONS Data Current as of 02/01/00 Information for SOUTHPORT TRADING COMPANY/PINE GROVE, LLC Corporation Id: 0512467 Date of Corporation: Nov 18 1999 Corporation Status: ACTIVl; .. .... .. Duration: NOV 2049 Category: Limited Liability Company FS ate of Incorporation: NC Country of Incorporation: UNITED S`I'AITS Registered Agent Information Registered Agent Name: CI-1R1ST01'I-IFIt M. CROUCH Address: 6314 0LLANDER DRIVI City: WILMING,fON State: NC Gip: 28403 Filings Return to exact name search Rclni•►► to soi►ildc.x sc,►rch Notice: Information presented on this Web site is collected, maintained, and provided for the convenience of the reader. While every effort is made to keep such information accurate and up-to-date, the Secretary of Slate does not certify the authenticity of information herein that originates from third parties. The Secretary of State shall under no circtnnslances he liable for any actions taken or omissions made from reliance on any information contained herein from whatever source or any other consequences from any such reliance. I of 1 02/13/2001 2:46 PM Date Design Andrew and Kuske 902 Market St. CONSULTING ENGINEERS. INC. Wilmi Check Job I For Pr A3 "L,)E D 0?- vrG k)lC'm1"iG-C-0&D t1i 6-1 I �Z H C AL 1i + 1966 z a, fttl� N , N.C. 28401 Sheet Job No. 4Fq 27 Z. o/ 105101 RECEIVED JAN 18 2001 nw PRoa # ? c lv27 Date Design Andrew and Kuske Sheet �i} 3 �0 902 Market St. CON$UITING ENGINEERS, INC. Wilmington. N.C. 28401 pt 2 Check Job For (���,�� 1 Job No, OTC, 5Tb 2n'I v�i r�fL � Pr ��✓� r�-�J y�j 2 Z 1 ,4 = ) %, (pLvCv 5� 0 2 4 30 �MeC-UivJ'f-� fir- 111,5) U Z-O SF ae_ 3-g02- A-e—' 22.) o 4-[i G oe.�-�- �n ,C::l a-S T // D 15 0/dw4C' 6 v O 1--t- 25 Ye7q-Q- -,-57r, 2�'J PaS '7, 5 /n ��i X Y/-• ?G8 AG x .j v - •Col Lo CAS rocs I0 ---rj D "-) 6-'r 4.; Tom-, Tr- o 70 2's -re_ 5 7 a 2er7 + lr Tit- q I LENcr7� a� 3t�'' Sec-T� o� : �'i)O ;7T o(opaCo ;77 Z) K �-T 3 2�" -no,J C�d Fl z - 3,0 FTz-) X 3�'� �►�� �o�P�� �i�- x loos � _ �; 1a3, � �=T; 2 P►P� 3 !wf (p �T� X jR4� = 1J LZSZ r3 V010 Pnd = 207-�Y' Fri �/� 850 i rT 2�, -7 -�74 97 Date Design Andrew and Kuske SC-� 902 Market St. CONSULTING ENGINEERS. INC. Wilmington. N.C. 28401 f 2 Check Job For Job No. a�Z7 5Tmh/k-f E I ,J 0 lzl�- = �T" 3 C nJoT roc woE� 6 -sue b 2 PE-PT74 C EZ r 5 7-o f `7 5) r �✓ .5MM ee ' X Po �� 17 Cog' fle��&-%j� Z Tvrn-l— 5�0,4,r c& e� ,oim-L = 21, 1:57 , 5� 2151 zl _3 , 4 �T 3 l n x (l ("0 6, 4Pzv F-Tz �- 2 �22� o4l& 21t 2�� FT Sr, -737,Fr C,9_� _ -;; 67- %ice I nJ[ C ✓tit/9 g4S o•J �2A�e.4 m P2/�/T 6vTS �i'S1 Ear wr�-C p��G /'VA 5o /&-) I� r' �715 Crd 2fv� Data for 99272 LOWES FOODS REVISED Page 1 TEN YEAR 24-HOUR RAINFALL= 7.00 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. HydroCAD 5.01 000479 (c) 1986-1998 Applied Microcomputer Systems SUBCATCHMENT 1 DRAINAGE AREA TO PIPE SYSTEM PEAK= 23.61 CFS @ 12.13 HRS, VOLUME= 1.38 AF ACRES CN SCS TR-20 METHOD 3.80 95 IMPERVIOUS SURFACE TYPE III 24-HOUR .50 39 OPEN, SOIL GROUP A RAINFALL= 7.00 IN 4.30 88 SPAN= 11-15 HRS, dt=.02 HRS Method Comment Tc min DIRECT ENTRY Segment ID: 10.0 22 20 18 16 � 14 u 12 v 10 O 8 J Li. 5 4 2 0m SUBCATCHMENT I RUNOFF DRAINAGE AREA TO PIPE SYSTEM In 0 n m In N vi M M TIME Chours) AREA= 4.3 AC Tc= 10 MIN CN= 88 SCS TR-20 METHOD TYPE III 24-HOUR RAINFALL= 7.00 IN PEAK= 23.61 CFS C' 12.13 HRS VOLUME= 1.36 AF m Ln w V V In Data for 99272 LOWES FOODS REVISED Page 2 TEN YEAR 24-HOUR RAINFALL= 7.00 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. HydroCAD_S.01 000479 _ (c)1986-1998 Applied Microcomputer Systems REACH I OUTLET TO ROADWAY Qin = 0.00 CFS Q 0.00 HRS, VOLUME= 0.00 AF Qout= 0.00 CFS Q 0.00 HRS, VOLUME= 0,00 AF, ATTEN= 0%, LAG= 0.0 MIN DEPTH END AREA DISCH (FT) (SO -FT) (CFS) 18" PIPE 0.0 0.0 0.00 .2 .1 .16 'n= .013 .3 .3 .65 LENGTH= 30 FT .5 .4 1.45 SLOPE= .005 FT/FT 1.1 1.3 6.22 1.2 1.5 7.26 1.4 1.7 7.92 1.4 1.7 7.99 1.5 1.8 7.92 1.5 1.8 7.43 10 9 8 7 � 6 u 5 :3 4 O -� 3 L� 2 1 0m STOR-IND+TRANS METHOD PEAK DEPTH= 0.00 FT PEAK VELOCITY= 0.0 FPS TRAVEL TIME = 0.0 M.IN SPAN= 11-15 HRS, dt=.02 HRS REACH I INFLOW & OUTFLOW OUTLET TO ROADWAY 18'' PIPE n=.013 L=30' 5=.005 STOR-IND+TRANS METHOD VELOCITY= 0 FPS TRAUEL= 0 MIN Oin= 0.00 CFS Qaut= 0.00 CFS LAG= 0 MIN in m in m in m Ln m N N TIME Chcur5) Data for 99272 LOWES FOODS REVISED Page 3 TEN YEAR 24-HOUR RAINFALL= 7.00 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. HVdroCAD 5.01 000479 (c) 1986-1998 Applied_ Microcomputer Systems_ POND 1 EXFILTRATION TRENCH Qin = 23.61 CFS @ 12.13 HRS, VOLUME= 1.38 AF Qout= 10.33 CFS 0 12.38 HRS, VOLUME= 1.38 AF, ATTEN= 56%, LAG= 15.5 MIN --Sb. Qpri= 0.00 CFS Q 0.00 HRS, VOLUME= 0.00 AF Qsec= 10.33 CFS @ 12.38 HRS, VOLUME= 1.38 AF Report reflects 52% open space ELEVATION AREA INC.STOR CUM.STOR (FT) _ (SF) (CF) (CF)_ _ 16.0 5580 0 0 20.0 15345 21762 21762 STOR-IND METHOD PEAK STORAGE = 15180 CF PEAK ELEVATION= 18.8 FT FLOOD ELEVATION= 20.0 FT START ELEVATION= 16.0 FT SPAN= 11-15 HRS, dt=.02 HRS Tdet= 13.2 MIN (1-38 AF) # ROUTE INVERT OUTLET DEVICES 1 P 19.5' 4' SHARP -CRESTED RECTANGULAR WEIR Q=C L H-1.5 C=3.27+.4 H/4 L=Length-2(.1 H) 2 S 0.0' EXFILTRATION V= .05 FPM over SURFACE AREA Primary Discharge I 1=Sharp-Crested Rectangular Weir Secondary Discharge I2=Exfiltration POND 1 INFLOW & OUTFLDW EXFILTRATION TRENCH 22 STOR-IND METHOD 20 PEAK STOR= 15180 CF 18 PEAK ELEO= 18.8 FT r 16 Din_ 23.61 CFS 0 Gout= 10.33 CF5 u 14 0Pri= 0.20 CF5 12 Qsec= 10.33 CFS 13 10 ` LAG= 15.5 MIN CD LL 6 % z e N N r`1 r*7 v Q N TIME Choirs) Data for 99272 LOWES FOODS REVISED Page 4 TEN YEAR 24-HOUR RAINFALL= 7.00 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. HydroCAD 5.01 000479 (c) 1986-19.98 Applied Microcomputer Systems POND 2 OPEN EXFILTRATION POND Qin = 0.00 CFS @ 0.00 HRS, VOLUME= 0.00 AF Qout= 0.00 CFS @ 0.00 HRS, VOLUME= 0.00 AF, ATTEN= 0%, LAG= 0.0 MIN Qpri= 0.00 CFS @ 0.00 HRS, VOLUME= 0.00 AF Qsec= 0.00 CFS @ 0.00 HRS, VOLUME= 0.00 AF ELEVATION AREA INC.STOR CUM.STOR STOR-IND METHOD (FT) (SF) (CF) (CF) PEAK STORAGE = 0 CF 17.5 1160 0 0 PEAK ELEVATION= 17.5 FT 18.5 1700 1430 1430 FLOOD ELEVATION= 19.5 FT 19.5 2320 2010 3440 START ELEVATION= 17.5 FT SPAN= 11-15 HRS, dt=.02 HRS #(_ RO_UTE INVERT OUTLET_ DEVICES 1 S 0.0' EXFILTRATION - - - V= .05 FPM over SURFACE AREA 2 P 18.5' 12, SHARP -CRESTED RECTANGULAR WEIR Q=C L H-1.5 C=3.27+.4 H/3 L=Length-0(.1 H) Primary Discharge � 2=Sharp-Crested Rectangular Weir Secondary Discharge � I=Exfiltration 10 9 8 6 U 5 3 q O � 3 2 1 0m POND 2 INFLOW! & OUTFLOIJ OPEN EXFILTRATION POND STDR-IND METHOD PEAK STDR= 0 CF PEAK ELEV= 17.5 FT Qin= 0.00 CF5 Oout= 0.00 CFS Opri= 0.00 CFS Qsec- 0.00 CFS LAG= 0 MIN Ln m n m Ln m Ln m N N M P7 V V Ln TIME (hours) Data for 99272 LOWES FOODS REVISED Page 5 25 YEAR 24-HOUR RAINFALL= 8.00 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. HvdroCAD 5.01 000479 (c) 1986-1998 Applied Microcomputer Svstems SUBCATCHMENT 1 DRAINAGE AREA TO PIPE SYSTEM PEAK= 27.48 CFS @ 12.12 HRS, VOLUME= 1.61 AF ACRES CN SCS TR-20 METHOD 3.80 95 IMPERVIOUS SURFACE TYPE III 24-HOUR .50 39 OPEN, SOIL GROUP A RAINFALL= 8.00 IN 4.30 88 SPAN= 11-15 HRS, dt=.02 HRS Method Comment _ T Tc Amin] DIRECT ENTRY Segment ID: 10.0 26 24 22 20 kO 18 L.- 16 U 14 3 12 O 10 B 61 2 Om SUBCATCHMENT 1 RUNOFF DRAINAGE AREA TO PIPE SYSTEM L, m n CD Ln N N M M TIME (hours) AREA= 4.3 AC Tc= 10 MIN CN= 8B SCS TR-20 METHOD TYPE III 24-HOUR RAINFALL= 6.03 IN PEAK= 27.46 CF5 C 12.12 HRS VOLUME= 1.61 AF m L, m V V Ln Data for 99272 LOWES FOODS REVISED Page 6 25 YEAR 24-HOUR RAINFALL= 8.00 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. HydroCAD 5_.01 000479 (c)_ 1986-19.98 Applied-MicrocomputerSystems REACH 1 OUTLET TO ROADWAY Qin = 0.00 CFS Q 0.00 HRS, VOLUME= 0.00 AF Qout= 0.00 CFS @ 0.00 HRS, VOLUME= 0.00 AF, ATTEN= 00, LAG= 0.0 MIN DEPTH END AREA DISCH (FT) (SQ-FT) (CFS)_ 0.0 0.0 0.00 .2 .1 .16 .3 .3 .65 .5 .4 1.45 1.1 1.3 6.22 1.2 1.5 7.26 1.4 1.7 7.92 1.4 1.7 7.99 1.5 1.8 7.92 1.5 1.8 7.43 10 9 B 7 r-, c- 6 U 5 3 q O `j 3 LL- 1 0� 18" PIPE n= .013 LENGTH= 30 FT SLOPE= .005 FT/FT STOR-IND+TRANS METHOD PEAK DEPTH= 0.00 FT PEAK VELOCITY= 0.0 FPS TRAVEL TIME = 0.0 MIN SPAN= 11-15 HRS, dt=.02 HRS REACH I INFLOW & OUTFLOW OUTLET TO ROADWAY 18'' PIPE n=.013 L=30' 5=.005 STOR-IND+TRANS METHOD UELOCITY= 0 FPS TRAVEL= 0 MIN O�n= 3 20 CFS Gout= 0.00 CF5 LAG= 0 MIN Ln m u, m Ln m in m -- N N f'l r'"1 v v !n TIME (hour5) Data for 99272 LOWES FOODS REVISED Page 7 25 YEAR 24-HOUR RAINFALL= 8.00 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. HydroCAD 5.01_ 000479 (c) 1986-1998 Applied Microcomputer Systems POND 1 EXFILTRATION TRENCH Qin = 27.48 CFS G 12.12 HRS, VOLUbIE= 1.61 AF Qout= 11.71 CFS @ 12.39 HRS, VOLUZIE= 1.61 AF, ATTEN= 57%�, LAG= 15.9 MIN Qpri= 0,00 CFS 9 0.00 HRS, VOLU1`EE= 0.00 AF Qsec= 11.71 CFS @ 12.39 HRS, VOLUI`IE= 1.61 AF Report reflects 52% open space ELEVATION AREA INC.STOR CUM.STOR FT SF CF CF 16.0 5580 0 0 20.0 15345 21762 21762 STOR-IND METHOD PEAK STORAGE = 18885 CF PEAK ELEVATION= 19.5 FT FLOOD ELEVATION= 20.0 FT START ELEVATION= 16.0 FT SPAN= 11-15 HRS, dt=.02 HRS Tdet= 15.2 MIN (1.6 AF) -4L_R_OUTE INVERT _ OUTLET DEVICES _ 1 P 19.5' 4' SHARP -CRESTED RECTANGULAR WEIR Q=C L H^1.5 C=3.27+.4 H/4 L=Length-2(.1 H) 2 S 0.0' EXFILTRATION V= .05 FPM over SURFACE AREA Primary Discharge I 1=Sharp-Crested Rectangular weir Secondary Discharge � 2=Exfiltration kn U 3 0 LL 26 24 22 20 18 16 14 12 10 8 6 4 2, 6.10 POND I INFLOW & OUTFLOW EXFILTRATION TRENCH STOR-IND METHOD PEAK STCR= 18685 CF PEAK ELEV= 19.5 FT Oin= 27.49 CFS Ooui= 11.71 CFS Opri= 0.03 CFS Qsec= 11,71 CFS LAG= 15.9 MIN 1 m in - m Ln m TT- Lg (hours) Data for 99272 LOWES FOODS REVISED Page 8 25 YEAR 24-HOUR RAINFALL= 8.00 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. HVdroCAD 5.01 000479 (c) 1986-1998 Applied Microcomputer Systems POND 2 OPEN EXFILTRATION POND a Qin = 0.00 CFS fl 0.00 HRS, VOLUME= 0.00 AF Qout= 0.00 CFS @ 0.00 HRS, VOLUME= 0.00 AF, ATTEN= 0%, LAG= 0.0 MIN Qpri= 0.00 CFS @ 0.00 HRS, VOLUME= 0.00 AF Qsec= 0.00 CFS p 0.00 HRS, VOLUME= 0.00 AF ELEVATION AREA INC.STOR CUM.STOR STOR-IND METHOD (FT) (SF) (CF) (CF) PEAK STORAGE = 0 CP 17.5 1160 0 0 PEAK ELEVATION= 17.5 FT 18.5 1700 1430 1430 FLOOD ELEVATION= 19.5 FT 19.5 2320 2010 3440 START ELEVATION= 17.5 FT SPAN= 11-15 HRS, dt=.02 HRS # ROUTE INVERT OUTLET DEVICES 1 S 0.0' EXFILTRATION - V= .05 FPM over SURFACE AREA 2 P 18.5' 12, SHARP -CRESTED RECTANGULAR WEIR Q=C L H-1.5 C=3.27f.4 H/3 L=Length-0(.1 H) Primary Discharge 12=Sharp-Crested Rectangular weir Secondary Discharge 11=Exfiltration POND 2 INFLOW & OUTFLOW OPEN EXFILTRATION POND STOR-IND METHOD PEAK STOR= 0 CF PEAK ELEV= 17 5 FT Din= 0.20 CFS Oout= 2.00 CFS Qpr- � = 0.03 CFS Osec= 0.02 CFS LAG= 0 MIN 0 m cn m un m in m N N rry r') v v in TIME (hours) Data for 99272 LOWES FOODS REVISED Page 9 50 YEAR 24-HOUR RAINFALL= 9.00 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. HydroCAD_5._01 000479_ LZ 1986-1998 Applied Microcomputer Systems_ SUBCATCHMENT 1 DRAINAGE AREA TO PIPE SYSTEM PEAK= 31.34 CFS @ 12.12 HRS, VOLUME= 1.84 AF ACRES CN SCS TR-20 METHOD 3.80 95 IMPERVIOUS SURFACE TYPE III 24-HOUR .50 39 OPEN, SOIL GROUP A RAINFALL= 9.00 IN 4.30 88 SPAN= 11-15 HRS, dt=.02 HRS Method _ _ - Comment Tc (min) DIRECT ENTRY Segment ID: 10.0 30 28 26 24 22 20 `Y 18 16 14 0 12 J 10 LL e 6 4 2 BL SUSCATCHMENT 1 RUNOFF DRAINAGE AREA TO PIPE SYSTEM Ul m N Co Ln N N r"7 M TIME (hours) AREA= 4.3 AC Tc= 10 MIN CN= 88 SCS TR-20 METHOD TYPE III 24-HOUR RAINFALL= 9.B0 IN PEAK= 31.34 CFS 2 12.12 HRS UOLUME= 1.84 AF m V V Ln Data for 99272 LOWES FOODS REVISED Page 10 50 YEAR 24-HOUR RAINFALL= 9.00 IN Prepared by ANDREW L KUSKE CONSULTING ENGINEERS, INC. HydroCAD 501 000479_ (c) 1986-1998 Applied Microcomputer Systems REACH 1 OUTLET TO ROADWAY Qin = 0.00 CFS Q 0.00 HRS, VOLUME= 0.00 AF Qout= 0.00 CFS @ 0.00 HRS, VOLUME= 0.00 AF, ATTEN= 0%, LAG= 0.0 MIN DEPTH END AREA DISCH (FT) (SO -FT) (CFS) 0.0 0.0 0.00 .2 .1 .16 .3 .3 .65 .5 .4 1.45 1.1 1.3 6.22 1.2 1.5 7.26 1.4 1.7 7.92 1.4 1.7 7.99 1.5 1.8 7.92 1.5 1.8 7.43 181, PIPE n= .013 LENGTH= 30 FT SLOPE= .005 FT/FT STOR-IND+TRANS METHOD PEAK DEPTH= 0.00 FT PEAK VELOCITY= 0.0 FPS TRAVEL TIME = 0.0 MIN SPAN= 11-15 HRS, dt=.02 HRS REACH I INFLOW & OUTFLOW OUTLET TO ROADWAY 18" PIPE n= 213 L=30' 5=.005 STDR-IND+TRANS METHDD VELDCITY= 0 FPS TRAVEL= 0 MIN Din= 0.00 CFS Oout= 0.00 CF5 LAG= 0 MIN Ln Ln m n co L CD N N TIME (hours) Data for 99272 LOWES FOODS REVISED Page ii 50 YEAR 24-HOUR RAINFALL= 9.00 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. EvdroCAD 5.01 000479 (c)_1986-1998 Applied Microcomputer Systems _ POND 1 EXFILTRATION TRENCH Qin = 31.34 CFS p 12.12 HRS, VOLUME= 1.84 AF Qout= 16.16 CFS 9 12.32 HRS, VOLUME= 1.83 AF, ATTEN= 48%, LAG= 12.0 MIN Qpri= 3.54 CFS @ 12.32 HRS, VOLUME= 06 AF Qsec= 12.62 CFS @ 12.32 HRS, VOLUME= 1.77 AF Report reflects 52% open space ELEVATION AREA INC.STOR CUM.STOR (FT) (SF) _ (CF) (CF) 16.0 5580 0 0 20.0 15345 21762 21762 STOR-IND METHOD PEAK STORAGE = 21323 CF PEAK ELEVATION= 19.9 FT FLOOD ELEVATION= 20.0 FT START ELEVATION= 16.0 FT SPAN= 11-15 HRS, dt=.02 HRS Tdet= 15.7 MIN (1.82 AF) # ROUTE INVERT OUTLET DEVICES 1 P 19.5' 4' SHARP -CRESTED RECTANGULAR WEIR Q=C L H-1.5 C=3.27+.4 H/4 L=Length-2(.1 H) 2 S 0.0' EXFILTRATION V= .05 FPM over SURFACE AREA Primary Discharge 11=Sharp-Crested Rectangular Weir Secondary Discharge L---2=Exfiltration POND 1 INFLOW & OUTFLOW EXFILTRPTION TRENCH 30 26 STOR-IND METHOD 26 PEAK STOR= 21323 CF 24 PEAK ELEV= 19.9 FT 22 OIn= 31.34 CF5 20 Oout= 16.16 CFS 18 U Opr1= 3.54 CF5 16 r Osec= 12 62 CF5 1 2 ! ` LAG= 12 MIN fr .= LL B � \ 4 2 ' 0m (n m in m in m Ln m r) un TIME (hours) Data for 99272 LOWES FOODS REVISED Page 12 50 YEAR 24-HOUR RAINFALL= 9.00 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. H droCAD 5.01 000479 c 1986-1998 Applied Microcom user Systems POND 2 OPEN EXFILTRATION POND Qin = 3.54 CFS Q 12.32 HRS, VOLUME= .06 AF Qout= 1.39 CFS @ 12.47 HRS, VOLUME= .06 AF, Qpri= 0.00 CFS 0 0.00 HRS, VOLUME= 0.00 AF Qsec= 1.39 CFS 9 12.47 HRS, VOLUME= 06 AF ELEVATION AREA INC.STOR CUM.STOR (FT) (SP) (CF) (CF) 17.5 1160 0 0 18.5 1700 1430 1430 19.5 2320 2010 3440 ATTEN= 61$, LAG= 8.7 MIN STOR-IND METHOD PEAK STORAGE = 1354 CF PEAK ELEVATION= 18.4 FT FLOOD ELEVATION= 19.5 FT START ELEVATION= 1-1.5 FT SPAN= 11-15 HRS, dt=.02 HRS Tdet= 10.6 MIN (.06 AF) # ROUTE INVERT OUTLET DEVICES 1 S 0.0' EXFILTRATION V= .05 FPM over SURFACE AREA 2 P 18.5' 12, SHARP -CRESTED RECTANGULAR WEIR Q=C L H^1.5 C=3.27+.4 H/3 L=Length-O(.1 H) Primary Discharge 12=Sharp-Crested Rectangular Weir Secondary Discharge I I=Exfiltration 3.4 3.2 3.0 2.8 2.6 2.4 2.2 u 2.0 v I.B 1.6 (:D 1 .4 J 1.2 IL 1 .0 .8 .6 .4 .2 0.0m POND 2 INFLOW 8 OUTFLOW OPEN EXFILTRATION POND STOR-IND METHOD PEAK $TOR= 1354 CF PEAK ELEu= 18.4 FT 4 In m N m In TIME (hours) Qin= 3.54 CF5- Oout= 1,39 CF5 Opri= 0.00 CF5 Qsec= 1.39 CFS LAG= 8.7 MIN IT v In Andrew &Kuske John R. Andrew, P.E, CONSULTING ENGINEERS, INC. J.A. Kuske, P.E. J. Phillip Norris, P.E. 902 Market St. • Wilmington, North Carolina 28401 A733 • Telephone 910/343-9653 • Fox 910/343-9604 + okengnrs®wilmington.net October 16, 2000 Ms. Linda Lewis NC DENR Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Re: Lowe's Foods — Pine Grove Road New Hanover County State Stormwater Permit Submittal A&K Project No. 99272 Dear Ms. Lewis: Enclosed are two sets of plans for the subject project, one set of calculations, the original Division of Water Quality stormwater management permit application, and one copy, one copy of the SWU-103 and SWU-107 supplement forms, one copy of the stormwater narrative and a $420.00 check for the processing fee. Please review this information for approval and contact us with any questions or comments you may have. Thank you for your assistance on this project. Sincerely, ANDREW & KUSKE CONSU ENGINEERS, I C. illip Norris, P. E. 99272-101600swi Enclosures CC" Nick Garrett, Jr. STORMWATER SYSTEM NARRATIVE LOWE'S FOODS PINE GROVE ROAD NEW HANOVER COUNTY, NORTH CAROLINA For Southport Trading Co. PO Box 4893 Wilmington, NC 28406 ,l1111110" y N CAR AL 11966 • 0 ''�11AIt111111ta�t October, 2000 Prepared by: RECEIVED OCT 2-4 2000 DWQ PROM # S U) FOC) k o zq ANDREW & KUSKE CONSULTING ENGINEERS, INC. 902 Market Street Wilmington, North Carolina 28401 910/343-9653 910/343-9604 — Fax www.andrewandkuske.com A & K #99272 3 NARRATIVE STORMWATER MANAGEMENT The project site is located in New Hanover County at the corner of Greenville Loop Road and Pine Grove Road. Land disturbing on the site will exceed one acre, which requires the site to comply with the Stake Regulations. The stormwater runoff from the development will be directed to an infiltration stormwater system. The stormwater system was designed to accommodate this site at 88.25% impervious area lot coverage and a minimum of 1.5 inches infiltration as the site drains to SA waters. The system is designed to allow no discharge in rainfall events up to the 25-year storm. K