HomeMy WebLinkAboutSW6210303_Ez Supplement Form 2_20210329SUPPLEMENT-EZ COVER PAGE
I FORMS LOADED
PROJECT INFORMA11ION
1
1 Project Name
Watson Ridge
2
Project A a (ac)
39.625
3
Coastal Welland Area (ac)
4
Surface Water Area (ac)
0.429
5
1 Is this project High or Low Density?
High
6
� Does this project use an off -site SCIVI?
No
COMPUANCE VkqTH 02H.IWX4)
7 Width of veget 3!
30
8 lWill the vegetated setback remain vegetated?
Yes
- ----
9 If BILIA is proposed in the setback, does it meet NCAC 021-110�4 c,1E_
No
lo Its strearnbank stabilization proposed on this project?
No
NUMBER AND TYPE OF SCMs:
11
Infiltration System
2
12
Bioretention Celi
0
13
Wet Pond
1
14
Stormwater Wetiand
a
16
Permeable Pavement
0
16
Sand Filter
0
17
Rainwater Harvesting (RWH)
0
18
Green Roof
0
19
Level Spreader -Filter Strip (LS-FS)
0
20
Disconnected ImperviousSurfage (Dlq�__
0
21
Treatment Swale
0
22
ond
0
-D
23
StormFilter
0
24
Silva Cell
0
25
Bayfilter
0
26
Filterra
0
I FORMS LOADED
0WOMRCERTWWATION
27
�Narne and Title:
Matt Lowder, PE
28
lOrganization:
Triangle Site sign, PILLC
29
Street address-
4DO4 Barrett Drive, Suite 101
30
!City, S ate, Zip:
Raleigh, NC 27609
31
1 Phone number(s):
91"53-6570
32
1 Email:
mlowder@triangles4odesign.com
10411fication stmernall
I oertify, under penalty of law that ibis Supplemeryt-EZ form and all supporting i. ifon. were prepared under rny direction or supervision; VW the
lnforma*)n provided in the form is, to the beM of my knowledge and boW trus, aocurale, and complete; and tat the engineering plans,
sp�fions. operation and maintenar4s, agreements and other suppoiAng Information are consistanit with the information provided have.
%
Seal
Signalure of Designer
Date
DRAINAGE AREAS
I
Is this a high density project?
Yes
2
If so, number of drainage areas/SCMs
3
3
Does this project have low density areas?
No
4
if so, number of low density drainage areas
—0
5
Is allipart of this project subject to previous rule
versions?
No
I FORMS LOADED
DRAINAGE AREA INFORKATON
EnUre Sift
1
2
3
4
Type of SCM
-
Infiltration Basin
Infiltration Basin
Wet Pond
5
Total drainage area (sq ft)
1010204
262994
425090
322120
6
Onsite drainage area (sq ft)
987169
239959
425090
322120
7
Oftite drainage area (sq ft)
23035
23035
8
Total BOA in project (sq ft)
230951
73115 sf
99538 sf
58298 sf
9
New BUA on subdivided lots (subject to permitting)
(sq ft)
10
New BUA not on subdivided lots (subject to
permitting) (sf)i
11
Offsite BUA (sq ft)
7686
76M sf
12
Breakdown of new BUA not on subdivided lots:
Parking (sq It)
Sidewalk (sq ft)
Roof (sq ft)
168000
48000 Sf
72000 sf
48000 sf
Roadway (sq ft)
55265
17429 sf
27538 sf
10298 sf
Future (sq ft)
Other, please specify in the comment box
below (sq ft)
13
New infiltrating permeable pavement on
subdivided lots (sq ft)
14
New infiltrating permeable pavement not on
subdivided �ots (sq ft)
15
Existing BUA that will remain (not subject to
permitting) (sq ft)
16
1 Existing BUA that is already permitted (sq ft)
17
Existing BUA that will be removed (sq ft)
18
Percent BUA
28%
23%
18%
19
�s
Design storm Ciqq�e
1.0 in
1.0 in
1.0 in
20
Design volume of SCIVI (cu ft)
6579 cf
9237 ef
5715 ef
21
Calculation method for design volume
Simple Method
Simple Method
Simple Method
ADDrrK)NAL INFORMATION
I
22
IPlease use this space to provide any additional information about the
drainage area(s)�
Inilittration Basin #11 - there is oftite drainage area from the Lee County
portion of the overall development.
I
INFILTRATION SYSTEM
Drainage area number 1 2
2 1 Minimum required treatment volume (cu ft) 6579 Ct 9237 ef
3 1
Is the SCM sized to treat the SW from all Surfaces at build -out?
yes
Yes
4
Is the SCM located away from contaminated soils?
Yes
Yes
What are the side slope$ of the SCM (H:V or enter "Vertical" for
5
trenches)?
3A
3:1
6
Does the SCM have retaining walls. gabion walls or other engineered
side slopes?
No
No
7
Are the inlets, outlets, and receiving stream protected from erosion
(1 0-yea r storm)?
Yes
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
design volume?
Yes
Yes
9
What is the method for dewatering the SCM for maintenance?
Pump (preferred)
Pump (preferred)
10
If applicable, will the SCM be cleaned out after construction?
Yes
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
Yes
13
If the SCM is on a single family lot, does (411?) the plat comply with
General MDC (10)?
NIA
N/A
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
Yes
15
Is there an O&M Plan that complies Wth General MDC (12)?
Yes
Yes
16
1 Does the SCIM follow the device specific MDC?
Yes
Yes
17
lWas the SCM desioned bv an NC licensed professional?
Yes
yes
18 Proposed slope of the subgrade surface(%)
19 Are terraces or battles provided? No No
20 ITyp_e_of pretreatment: Forebay Forebay
C.ilk 1110.
21
Was the soil investigated in the footprint and at the elevation of the
infiltration system?
Yes
Yes
22
SHWT elevation (fmsl)
365.50
332.00
23
Depth to SHWT per soils report (in)
72.00
56.00
24
Ground elevation at boring in soils report (fmsl)
371,50
336.60
25
tio 7
Is a detailed hydrogeologic study attached if the separa n is
between 1 and 2 feet?
Yes
Yes
26
Soil infiltration rate (in/hr)
9.00
10.0
27
Factor of safety (FS) (2 is reGommended)�
2.00
7 =_00
1j=1A%wjftVnnC
29
Bottom elevation (fmsi)
371 ft
336 ft
3o
Storage elevation (fmsl)
372� ft
337. ft
31
Bypass elevation (frnsl)
373.2 fl
338.8 ft
34
Length (fl)
35
............
Width (ft)
36
Perforated pipe diame ter, if applicable (inches)
37
Number of laterals
38
Total length of perforated piping
39
Stone type, if applicable
40
Stone porosily (%)
I - -
1
41
is stone free of fines?
42
Is the stone wrapped in geotextile fabric?
43
Has at least one inspection port been provided?
VolmimatDiawdolm
44 IDesign volume ofSCM (cu ft) 6579 af 9237 cf
45 1 Time to draw down (hours) 72 hrS 72 hrs
46 Please use this space to provide any additional information about the
linfiltration syslem(s): I
Infiltration 2:35 PM 3/4/2021