Loading...
HomeMy WebLinkAboutSW3210101_300-SIA Report_20210111r-t.!:wMb-4& aw: IF r ,74 d A _1 THE GLENNS Stormwater Impact Analysis and Final Design of Stormwater Control Measure '1 WADAMS 4A 400000 NO THE GLENNS The Town of Wingate, North Carolina Stormwater Impact Analysis & Design of Stormwater Control Measure Project Number: TRU-19030 Designed By: Michael Duval, PE Date: December 2020 �J MCADAMS 3430 Toringdon Way, Suite 110 Charlotte, North Carolina 28277 NC Lic. # C-0293 9 MCADAMS STORMWATER IMPACT ANALYSIS GENERAL DESCRIPTION Located east of Ansonville Rd and north of Monroe Expressway in the Town of Wingate in Union County, North Carolina, is the proposed development known as The Glenns. The existing site consists of areas of woods and trails. Proposed development on this site will consist of the construction of single-family homes, along with associated roads, sidewalks, utility improvements and one stormwater control measure. The proposed development is located within the Yadkin River basin with stormwater runoff from the proposed development draining into the Meadow Branch & Austin Branch in the Richardson Creek Watershed. Per Town of Wingate regulations, stormwater management on this site shall meet the stormwater management performance standards for development set forth in the Town of Wingate Code of Land Ordinances & NCDEQ MDC. These are as follows: 6.5 Stormwater Management for the Town of Wingate, NC. All developments shall be constructed and maintained so that adjacent properties are not unreasonably burdened with surface waters as a result of such developments. A. No development may be constructed or maintained so that such development impedes the natural flow of water from higher adjacent properties across such development, thereby causing damage to such higher adjacent properties; and B. No development may be constructed or maintained so that surface waters from such development are collected and channeled onto lower adjacent properties at such locations or at such volumes as to cause damage to lower adjacent properties. 15A NCAC 02H.1003 NCDEQ Requirements that apply to all projects. DESIGN REQUIREMENTS FOR HIGH DENSITY PROJECTS. High density projects are projects that do not conform to Item (2) of this Rule. High density projects shall meet the following minimum design criteria: (a) TREATMENT REQUIREMENTS. SCMs shall be designed, constructed, and maintained so that the project achieves either "runoff treatment" or "runoff volume match" as those terms are defined in Rule .1002 of this Section. (b) OFF -SITE STORMWATER. Stormwater runoff from off -site areas and existing development shall not be required to be treated in the SCM. Runoff from off -site areas or existing development that is not bypassed shall be included in the sizing of on -site SCMs at its full built -out potential. (c) OFF -SITE SCM. A project that controls runoff through an off -site SCM shall be allowed on a case -by - case basis as determined by the permitting authority if the off -site SCM meets the provisions of Rules .1050 through .1061 of this Section. (d) EXPANSION OR REPLACEMENT OF EXISTING DEVELOPMENT. When new built -upon area is added to existing development or existing development is replaced with new built -upon area, only the area of net increase shall be subject to this Section. creating experiences through experience 3430 Toringdon Way, Suite 110, Charlotte, NC 28277 / 704. 527. 0800