HomeMy WebLinkAboutSW8001009_Current Permit_20090509��A NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director May 18, 2009 Mr. Rick Blacher, Owner Smith Creek Storage Facilities, Inc 5633 Market St. Wilmington, NC 28405 Subject: Approved Plan Revision Smith Creek Boat Storage Stormwater Project No. SW8 001009 New Hanover County Dear Mr. Blacher: Dee Freeman Secretary On April 16, 2009, the Wilmington Regional Office received a plan revision for Stormwater Management Permit Number SW8 001009. The revisions include an additional building and wash down areas that were not previously included on the January 10, 2005 approved plan. The future impervious allocation of 2,221 sf for this permit is now limited to 1,324 sf. It has been determined that a formal permit modification is not required for the proposed changes. We are forwarding you an approved copy of the revised plans for your files. Please replace the old approved plan sheet with the new one. Please be aware that all terms and conditions of the permit issued on January 10, 2005, remain in full force and effect. Please also understand that the approval of this revision to the approved plans for the subject State Stormwater Permit is done on a case -by -case basis. Any other changes to this project must be approved through this Office prior to construction. The issuance of this plan revision does not preclude the permittee from complying with all other applicable statutes, rules, regulations or ordinances which may have jurisdiction over the proposed activity, and obtaining a permit or approval prior to construction. If you have any questions concerning this matter, Georgette Scott or me at (910) 796-?215. r Sincer / David Cox Environmental Senior Specialist please do not hesitate to call GDS1dwc: S:IWQSISTORMWATERIPERMIT1001009PR.may09 cc: Charlie Cazier, P.E. New Hanover County Building Inspections David Cox Wilmington Regional Office Central Files Wilmington Regional Office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 Phone: 910-796-72151 FAX: 910-350-20041 Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer NonrthCarohna Natumllff 04/16/09 Stormwater Narrative Smith Creek Storage Facility Phase I New Hanover County, NC PN 100-014 Smith Creek Storage Facility is an existing site which received a stormwater permit modification on January 10, 2005. The site was constructed slightly different then the permitted set of plans. We have reviewed the site and have approximate current impervious area numbers based on as -built survey information from Chris Clover PLS. The Current site has 41,704 sf of Building, 67,412 sf of parking, 1,489 sf of sidewalks/concrete, and allocation for 1,524 sf of future impervious coverage. Therefore the total of 111,929 sf and 71% impervious coverage remains the same as the January lo, 2005 permit. The Smith Creek Storage Facility was permitted high density treated by a wet detention facility. The pond has been constructed and will be verified for correct installation prior to certification. Runoff from this site will ultimately reach Spring Branch Classification "C-SW". Azk*.�Q� �" APP 1. V o By �00 DWQ USE ONLY Date Received Fee Paid Permit Number State of North Carolina Department of Environment and Natural Resources Division of Water Quual t,- STORMWATER MANAGEMENT PERMIT APPLICA' N FORM This form may be photocopied for use as an original r �f� V �ry I. GENERAL INFORMATION 1. Applicants name (specify the name of the corporation, individual, etc. who owns the project): Smith Creek Storage Facilities, Inc. 2. Print Owner/Signing Official's name and title (person legally responsible for facility and compliance): Rick Blacher/ er '�rQ•,;�o,r� 3. Mailing Address for person listed in item 2 above: 5633 Market St. City:Wilmington State:NC Zip:28405 Phone: (910 791-2005 Fax: (910 ) 793-1004 Email:blacher209@aol.com 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): Smith Creek Storage Facility Phase I 5. Location of Project (street address): 5633 Market St. City:Wih m lon County:New Hanover Zip:28405 6. Directions to project (from nearest major intersection): At the intersection of NC 17 and NC 74 Travel north on 17 approximately 0.15mi and turn left on service rd. Site will be on your right 5633 Market St. Smith Creek Storage. 7. Latitude:34° 15' 00" N Longitude:77° 51' 46" W of project 8. Contact person who can answer questions about the project: Name:Charles D. Cazier Telephone Number: (910 ) 409-3567 Email:Charlie@intracoastalengmeering.com II. PERMIT INFORMATION: 1. Specify whether project is (check one): ❑New ❑Renewal NModification Fonn SWU-101 Version 03.27.08 Page 1 of 4 2. If this application is being submitted as the result of a renewal or modification to an existing permit, list the existing permit numberSW8 001009 Mod and its issue date (if known)Tanuary 10,2005 3. Specify the type of project (check one): ❑Low Density ®High Density ❑Redevelop ❑General Permit ❑Universal SMP ❑Other 4. Additional Project Requirements (check applicable blanks; information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748): ❑CAMA Major NSedimentation/Erosion Control ❑404/401 Permit ❑NPDES Stormwater III. PROJECT INFORMATION 1. In the space provided below, summarize how stormwater will be treated. Also attach a detailed narrative (one to two pages) describing stormwater management for the project. Wet Detention Pond 2. Stormwater runoff from this project drains to the Cape Fear River basin. 3. Total Property Area: 3.64 acres 4. Total Wetlands Area: NA acres 5. 100' Wide Strip of Wetland Area: NA acres (not applicable if no wetlands exist on site) 6. Total Project Area**:3.64 acres 7. Project Built Upon Area:71.0 % 8. How many drainage areas does the project have?1 9. Complete the following information for each drainage area. If there are more than two drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. For high density projects, com lete the table with one drainage area for each engineered stormwater device. Basin Information Drainage Area 1 Drainage Area 2 Receiving Stream Name Spring Branch Stream Class & Index No. C-SW Total Drainage Area (sf) 3.64 On -site Drainage Area (sf) 3.64 Off -site Drainage Area (sf) - Existing Impervious* Area (sf) Proposed Impervious*Area (sf) 111,930 sf % Impervious* Area (total) 71.0 Impervious* Surface Area Drainage Area 1 Drainage Area 2 On -site Buildings (sf) 41,704 sf On -site Streets (sf) On -site Parking (sf) 67,412 sf On -site Sidewalks (so 1,489 sf Other on -site (so r� 1,324 sf Off -site (sf) Total (so: 111,929 sf Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. **Total project area shall be calculated based on the current policy regarding inclusion of wetlands in the built upon area percentage calculation. This is the area used to calculate percent project built upon area (BUA). Form SVVU-101 Version 03.27.08 Page 2 of 4 10. How was the off -site impervious area listed above derived?NA IV. DEED RESTRICTIONS AND PROTECTIVE COVENANTS One of the following deed restrictions and protective covenants are required to be recorded for all subdivisions, outparcels and future development prior to the sale of any lot. If lot sizes vary significantly, a table listing each lot number, size and the allowable built -upon area for each lot must be provided as an attachment. Forms can be downloaded from htip://h2o.enr.state.nc.us/su/bml2 forms.htm - deed restrictions. Form DRPC-1 High Density Commercial Subdivisions Form DRPC-2 High Density Developments with Outparcels Form DRPC-3 High Density Residential Subdivisions Form DRPC4 Low Density Commercial Subdivisions Form DRPC-5 Low Density Residential Subdivisions Form DRPC-6 Low Density Residential Subdivisions with Curb Outlets By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the applicable items required in the above form, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. V. SUPPLEMENT FORMS The applicable state stormwater management permit supplement form(s) listed below must be submitted for each BMP specified for this project. Contact the Stormwater and General Permits Unit at (919) 733-5083 for the status and availability of these forms. Forms can be downloaded from http://h2o.enr.state.nc.us/su/bml2 forms.htm. Form SW401-Low Density Form SW401-Curb Outlet System Form SW401-Off-Site System Form SW401-Wet Detention Basin Form SW401-Infiltration Basin Form SW401-Infiltration Trench Form SW401-Bioretention Cell Form SW401-Level Spreader Form SW401-Wetland Form SW401-Grassed Swale Form SW401-Sand Filter Form SW401-Permeable Pavement Low Density Supplement Curb Outlet System Supplement Off -Site System Supplement Wet Detention Basin Supplement Infiltration Basin Supplement Underground Infiltration Trench Supplement Bioretention Cell Supplement Level Spreader/Filter Strip/Restored Riparian Buffer Supplement Constructed Wetland Supplement Grassed Swale Supplement Sand Filter Supplement Permeable Pavement Supplement Form SWU-101 Version 03.27.08 Page 3 of 4 VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below. The complete application package should be submitted to the appropriate DWQ Office. (Appropriate office may be found by locating project on the interactive online map at hqp://h2o.enr.state.nc.us/su/msi maps htm) 1. Please indicate that you have provided the following required information by initialing in the space provided next to each item. - - • Original and one copy of the Stormwater Management Permit Application Form • Original and one copy of the Deed Restrictions & Protective Covenants Form (if required as per Part IV above) • Original of the applicable Supplement Form(s) and O&M agreement(s) for each BMP • Permit application processing fee of $505 (Express: $4,000 for HD, $2,000 for LD) payable to NCDENR • Calculations & detailed narrative description of stormwater treatment/management • Copy of any applicable soils report • Two copies of plans and specifications (sealed, signed & dated), including: - Development/Project name - Engineer and firm - Legend - North arrow - Scale - Revision number & date - Mean high water line - Dimensioned property/project boundary - Location map with named streets or NCSR numbers Initials ccr� t�le� - Original contours, proposed contours, spot elevations, finished floor elevations - Details of roads, drainage features, collection systems, and stormwater control measures - Wetlands delineated, or a note on plans that none exist Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations Drainage areas delineated - Vegetated buffers (where required) VII. AGENT AUTHORIZATION If you wish to designate authority to another individual or firm so that they may provide information on your behalf, please complete this section. (ex. designing engineer or firm) Designated agent (individual or firm):NA Mailing Address: City: State: Zip: Phone: ( ) Fax: Email: VIII. APPLICANT'S CERTIFICATION I, (print or type name of person listed in General Information, item 2) Richard Blacher certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective coven will be recorded, and that the proposed project complies with the requirements of 15A NCAC 21-1.1000. / / f/ Signature ! �����%�� 1 Date:_ Form SWU-101 Version 03.27.08 Page 4 of 4 DWQ USE ONLY Date Received Fee Paid Permit Number State of North Carolina Department of Environment and Natural Resources Division of rWater Qualiiy STORMWATER MANAGEMENT PERMIT APPLICATIORIVI� This form may be photocopied for use as an original V 19 I. GENERAL INFORMATION 1. Applicants name (specify the name of the corporation, individual, etc. who owns the project): Smith Creek Storage Facilities Inc. 2. Print Owner/Signing Official's name and title (person legally responsible for facility and compliance): Rick Blacher/ 'Pc®,7� JgMA 3. Mailing Address for person listed in item 2 above: 5633 Market St. City: Wilmington State:NC Zip:28405 Phone: (910 791-2005 Fax: (910 ) 793-1004 Email:blacher209@aol.com 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): Smith Creek Storage Facility Phase I 5. Location of Project (street address): 5633 Market St. City:Wilmington County:New Hanover Zip:28405 6. Directions to project (from nearest major intersection): At the intersection of NC 17 and NC 74 Travel north on 17 approximately 0.15mi and turn left on service rd. Site will be on your right 5633 Market St. Smith Creek Storage. 7. Latitude:34° 15' 00" N Longitude:77° 51' 46" W of project 8. Contact person who can answer questions about the project: Name:Charles D. CaZier Telephone Number: (910 ) 409-3567 Email:Charlie®intracoastalengineering_com _ II. PERMIT INFORMATION: 1. Specify whether project is (check one): MNew []Renewal ZModification Form SWU-101 Version 03.27.08 Page 1 of 4 2. If this application is being submitted as the result of a renewal or modification to an existing permit, list the existing permit numberSW8 001009 Mod and its issue date (if known)Tanuary 10,2005 3. Specify the type of project (check one): ❑Low Density NHigh Density ❑Redevelop ❑General Permit ❑Universal SMP ❑Other 4. Additional Project Requirements (check applicable blanks; information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748): ❑CAMA Major ®Sedimentation/Erosion Control ❑404/401 Permit ❑NPDES Stormwater III. PROJECT INFORMATION 1. In the space provided below, summarize how stormwater will be treated. Also attach a detailed narrative (one to two pages) describing stormwater management for the project. Wet Detention Pond 2. Stormwater runoff from this project drains to the Cape Fear River basin. 3. Total Property Area: 3.64 acres 4. Total Wetlands Area: NA acres 5. 100' Wide Strip of Wetland Area: NA acres (not applicable if no wetlands exist on site) 6. Total Project Area**:3.64 acres 7. Project Built Upon Area:71.0 % 8. How many drainage areas does the project have?1 9. Complete the following information for each drainage area. If there are more than two drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. For high density projects, complete the table with one drainage area for each engineered stormwater device. Basin Information Drainage Area 1 Drainage Area 2 Receiving Stream Name Spring Branch Stream Class & Index No. C-SW Total Drainage Area (sf) 3.64 On -site Drainage Area (sf) 3.64 Off -site Drainage Area (sf) - Existing Impervious* Area (sf) Proposed Impervious*Area Of) 111,930 sf % Impervious* Area (total) 71.0 Impervious* Surface Area Drainage Area 1 Drainage Area 2 On -site Buildings (sf) 41,704 sf On -site Streets (sf) On -site Parking (so 67,412 sf On -site Sidewalks (sf) 1,489 sf Other on -site (sf) 1,324 sf Off -site (sf) Total (sf): 111,929 sf " Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. **Total project area shall be calculated based on the current policy regarding inclusion of wetlands in the built upon area percentage calcu!aticn. This is the area used to calculate percent project built upon area (BUA). Form SWU-101 Version 03.27.08 Page 2 of 10. How was the off -site impervious area listed above derived?NA IV. DEED RESTRICTIONS AND PROTECTIVE COVENANTS One of the following deed restrictions and protective covenants are required to be recorded for all subdivisions, outparcels and future development prior to the sale of any lot. If lot sizes vary significantly, a table listing each lot number, size and the allowable built -upon area for each lot must be provided as an attachment. Forms can be downloaded from http://h2o.enr.state.nc.us/su/bml2 forms.htm - deed restrictions. Form DRPC-1 High Density Commercial Subdivisions Form DRPC-2 High Density Developments with Outparcels Form DRPC-3 High Density Residential Subdivisions Form DRPC-4 Low Density Commercial Subdivisions Form DRPC-5 Low Density Residential Subdivisions Form DRPC-6 Low Density Residential Subdivisions with Curb Outlets By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the applicable items required in the above form, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. V. SUPPLEMENT FORMS The applicable state stormwater management permit supplement form(s) listed below must be submitted for each BMP specified for this project. Contact the Stormwater and General Permits Unit at (919) 733-5083 for the status and availability of these forms. Forms can be downloaded from http://h2o.enr.state.nc.us/su/bml2 forms.htm. Form SW401-Low Density Form SW401-Curb Outlet System Form SW401-Off-Site System Form SW401-Wet Detention Basin Form SW401-Infiltration Basin Form SW401-Infiltration Trench Form SW401-Bioretention Cell Form SW401-Level Spreader Form SW401-Wetland Form SW401-Grassed Swale Form SW401-Sand Filter Form SW401-Permeable Pavement Low Density Supplement Curb Outlet System Supplement Off -Site System Supplement Wet Detention Basin Supplement Infiltration Basin Supplement Underground Infiltration Trench Supplement Bioretention Cell Supplement Level Spreader/Filter Strip/Restored Riparian Buffer Supplement Constructed Wetland Supplement Grassed Swale Supplement Sand Filter Supplement Permeable Pavement Supplement Form SWU-101 Version 03.27.08 Page 3 of 4 VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below. The complete application package should be submitted to the appropriate DWQ Office. (Appropriate office may be found by locating project on the interactive online map at ho://h2o.enr.state.ne.us/su/msi maps htm) 1. Please indicate that you have provided the following required information by initialing in the space provided next to each item. Initials • Original and one copy of the Stormwater Management Permit Application Form DG • Original and one copy of the Deed Restrictions & Protective Covenants Form (if NA required as per Part IV above) • OriginaI of the applicable Supplement Form(s) and O&M agreement(s) for each BMP • Permit application processing fee of $505 (Express: $4,000 for HD, $2,000 for LD) payable to NCDENR 11�JL, • Calculations & detailed narrative description of stormwater treatment/management GtX� • Copy of any applicable soils report • Two copies of plans and specifications (sealed, signed & dated), including: - Development/Project name - Engineer and firm -Legend - North arrow - Scale - Revision number & date - Mean high water line - Dimensioned property/project boundary - Location map with named streets or NCSR numbers - Original contours, proposed contours, spot elevations, finished floor elevations - Details of roads, drainage features, collection systems, and stormwater control measures - Wetlands delineated, or a note on plans that none exist - Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations - Drainage areas delineated - Vegetated buffers (where required) VII. AGENT AUTHORIZATION If you wish to designate authority to another individual or firm so that they may provide information on your behalf, please complete this section. (ex. designing engineer or firm) Designated agent (individual or firm):NA Mailing Address: City: State: Zip: Phone: ( ) Fax: Email: VIII. APPLICANT'S CERTIFICATION I, (print or type name of person listed in General Information, item 2) Richard Blacher certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective coven will be recorded, and that the proposed project complies with the requirements of 15A NCAC 2H .1 0% Signature: • Date: -� Form SWU-101 Version 03.27.08 Page 4 of 4 W State Stormwater Management Systems Permit No. SW8 001009 Modification STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Richard B/acher, Smith Creek Storage Facilities, Inc. Smith Creek Storage Facility Phase / New Hanover County FOR THE construction, operation and maintenance of a wet detention pond in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until January 10, 2015, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described in Section 1.6 on page 3 of this permit. The stormwater control has been designed to handle the runoff from 111,929 square feet of impervious area. 3. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans. The built -upon area for the future development is limited to 2,221 square feet. 4. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. 5. The runoff from all built -upon area within the permitted drainage area of this project mustLba directed into the permitted stormwater control system. Page 2 of 7 State Stormwater Management Systems Permit No. SW8 001009 Modification 6. The following design criteria have been provided in the wet detention pond and must be maintained at design condition: a. DrainaArea, acres: gnsite, 3.64 ft : 158,449 Offsite, ft2: None b. Total Impervious Surfaces, ft2: 111,929 C. Design Storm, inches: 1 d. Pond Depth, feet: 6.5 e. TSS removal efficiency: 90% f. Permanent Pool Elevation, FMSL: 24.00 g. Permanent Pool Surface Area, ft2: 6,603 h. Permitted Storage Volume, ft3: 10,159 i. Temporary Storage Elevation, FMSL: 25.37 j. Controlling Orifice: 1.5"0 pipe k. Permitted Forebay Volume, ft3: 3,018 I. Receiving Stream/River Basin: Spring Branch / Cape Fear M. Stream Index Number: 18-74-63-1 n. Classification of Water Body: "C;Sw" II. SCHEDULE OF COMPLIANCE 1. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device, flow spreader, catch basins and piping. g. Access to the outlet structure must be available at all times. Page 3 of 7 State Stormwater Management Systems Permit No. SW8 001009 Modification 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. Decorative spray fountains will be allowed in the stormwater treatment system, subject to the following criteria: a. The fountain must draw its water from less than 2' below the permanent pool surface. b. Separated units, where the nozzle, pump and intake are connected by tubing, may be used only if they draw water from the surface in the deepest part of the pond. c. The falling water from the fountain must be centered in the pond, away from the shoreline. d. The maximum horsepower for a fountain in this pond is 1/8 horsepower. 6. The facilities shall be constructed as shown on the approved plans. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 7. Ripon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. 8. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 9. Access to the stormwater facilities shall be maintained via appropriate easements at all times. 10. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area or to the drainage area. e. Further subdivision, acquisition, lease or sale of all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 11. The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction. 12. A copy of the approved plans and specifications shall be maintained on file b the Permittee for a minimum of ten years from the date of the completion of construction. Page 4 of 7 State Stormwater Management Systems Permit No. SW8 001009 Modification 13. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. III. GENERAL CONDITIONS This permit is not transferable except after notice to and approval by the Director. In the event of a change of ownership, or a name change, the permittee must submit a formal permit transfer request to the Division of Water Quality, accompanied by a completed name/ownership change form, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 6. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. 7. Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sedime^t Control Planning and Design Manual. 8. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 9. The permittee shall notify the Division any name, ownership or mailing address changes within 30 days. Permit issued this the 10t" day of January, 2005. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION 4 d" � Alan Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Page 5 of 7 Michael F. Easley, Governor William G. Ross, Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality Januray 10, 2005 Rick Blacher, Owner Smith Creek Storage Facilities, Inc. 5633 Market Street Wilmington, NC 28405 Subject: Stormwater Permit No. SW8 001009 Modification Smith Creek Storage Facility Phase I High Density Project New Hanover County Dear Mr. Blacher: The Wilmington Regional Office received a complete Stormwater Management Permit Application for Smith Creek Storage Facility Phase I on December 17, 2004. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW8 001009 Modification dated January 10, 2005, for the construction of the subject project. This permit shall be effective from the date of issuance until January 10, 2015, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Rhonda Hall, or me at (910) 395-3900. Sincerely, Rick Shiver Regional Supervisor Surface Water Protection Section RSS/rbh: S:IWQSISTORMWATIPERMIT1001009mod.jan05 cc: James Honeycutt, P. E., Honeycutt Engineering Joseph Gray, III, TMC-Taylor Construction, Inc. New Hanover County Building Inspections City of Wilmington Stormwater Services Beth E. Wetherill, New Hanover County Engineering Rhonda Hall Wilmington Regional Office Central Files North Carolina Division of Water Quality 127 Cardinal Drive Extension Phone (910) 395-3900 Customer Servicel-877-623-6748 Wilmington Regional Office Wilmington, NC 28405-3845 FAX (919) 733-2496 Internet: h2o.enr.state.nc.us One NofthCarollina An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper NQ't(1+M4 State Stormwater Management Systems Permit No. SW8 001009 Modification STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Richard Blacher, Smith Creek Storage Facilities, Inc. Smith Creek Storage Facility Phase 1 New Hanover County FOR THE construction, operation and maintenance of a wet detention pond in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until January 10, 2015, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described in Section 1.6 on page 3 of this permit. The stormwater control has been designed to handle the runoff from 111,929 square feet of impervious area. 3. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans. The built -upon area for the future development is limited to 2,221 square feet. 4. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. 5. The runoff from all built -upon area within the permitted drainage area of this project must be directed into the permitted stormwater control system. Page 2 of 7 State Stormwater Management Systems Permit No. SW8 001009 Modification 6. The following design criteria have been provided in the wet detention pond and must be maintained at design condition: a. Drainage Area, 9cres: 3.64 Onsite, ft : 158,449 Offsite, ft2: None b. Total Impervious Surfaces, ft2: 111,929 C. Design Storm, inches: 1 d. Pond Depth, feet: 6.5 e. TSS removal efficiency: 90% f. Permanent Pool Elevation, FMSL: 24.00 g. Permanent Pool Surface Area, ft2: 6,603 h. Permitted Storage Volume, ft3: 10,159 I. Temporary Storage Elevation, FMSL: 25.37 j. Controlling Orifice: 1.5" 0 pipe k. Permitted Forebay Volume, ft3: 3,018 I. Receiving Stream/River Basin: Spring Branch / Cape Fear M. Stream Index Number: 18-74-63-1 n. Classification of Water Body: "C;Sw" II. SCHEDULE OF COMPLIANCE 1. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device, flow spreader, catch basins and piping. g. Access to the outlet structure must be available at all times. Page 3 of 7 State Stormwater Management Systems Permit No. SW8 001009 Modification 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. Decorative spray fountains will be allowed in the stormwater treatment system; subject to the following criteria: a. The fountain must draw its water from less than 2' below the permanent pool surface. b. Separated units, where the nozzle, pump and intake are connected by tubing, may be used only if they draw water from the surface in the deepest part of the pond. c. The falling water from the fountain must be centered in the pond, away from the shoreline. d. The maximum horsepower for a fountain in this pond is 1/8 horsepower. 6. The facilities shall be constructed as shown on the approved plans. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. 8. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 9. Access to the stormwater facilities shall be maintained via appropriate easements at all times. 10. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area or to the drainage area. e. Further subdivision, acquisition, lease or sale of all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 11. The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction. 12. A copy of the approved plans and specifications shall be maintained on file by the ermittee for a minimum of ten years from the date of the completion of construction. Page 4 of 7 State Stormwater Management Systems Permit No. SW8 001009 Modification 13. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. III. GENERAL CONDITIONS 1. This permit is not transferable except after notice to and approval by the Director. In the event of a change of ownership, or a name change, the permittee must submit a formal permit transfer request to the Division of Water Quality, accompanied by a completed name/ownership change form, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 6. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. 7. Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 8. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 9. The permittee shall notify the Division any name, ownership or mailing address changes within 30 days. Permit issued this the 10t' day of January, 2005. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Alan W. Klimek, P�., Director Division of Water Quality By Authority of the Environmental Management Commission Page 5 of 7 State Stormwater Management Systems Permit No. SW8 001009 Modification Smith Creek Storage Facility Phase I Stormwater Permit No. SW8 001009 Modification New Hanover Countv Designer's Certification 1, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/ weekly/ full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specification: Signature Registration Number Date SEAL Page 6 of 7 State Stormwater Management Systems Permit No. SW8 001009 Modification Certification Requirements: _1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4. All roof drains are located such that the runoff is directed into the system. 5. The outlet/bypass structure elevations are per the approved plan. 6. The outlet structure is located per the approved plans. 7. Trash rack is provided on the outlet/bypass structure. 8. All slopes are grassed with permanent vegetation. 9. Vegetated slopes are no steeper than 3:1. 10. The inlets are located per the approved plans and do not cause short- circuiting of the system. 11. The permitted amounts of surface area and/or volume have been provided. 12. Required drawdown devices are correctly sized per the approved plans. 13. All required design depths are provided. 14. All required parts of the system are provided, such as a vegetated shelf, and a forebay. 15. The required system dimensions are provided per the approved plans. cc: NCDBNR-DWQ Regional Office New Hanover County Building Inspections Page 7 of 7 ::.::::............:.. . . 77. Received Fee Paid Permit Number _Date State of North Carolina Department of. Environment and Natural Resources xrxwxslOri Of Watter Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original I. GENERAL INFORMATION I. Applicants name (specify the name of the corporation, individual, etc. who owns the project): Smith Creek Storage Faei1ftT-.-hqg- Vg C , \ -, r,— . 2. Print Owner/Signing Official's name and title (person legally responsible for facility and compliance): Richard Blacher, Owner 3. Mailing Address for person listed in item 2 above: 5633 Market Street City: Wilmington State: NC Zip: 28405 Telephone Number: 910-799-5433 4. Project Name (subdivision, facility, or establishment name —should be consistent with project naive on plans, specifications, letters, operation and maintenance agreements, etc.): Smith Creek Storage Facility Phase I 5. Location of Project (street address): Service Road (SR 2650) City: Wilmington County: New Hanover 6. Directions to project (from nearest major intersection): From the intersection of US Hwy 17 and Hwy 74, travel 1 block northeast, turn left on Service Road. Site is on right on Service Road. 7. Latitude : N 34' 00' 00" Longitude: W 770 00' 00" of project 8. Contact person who can answer questions about the project: Naine: Jodie Gray Telephone Number: 910-251-1181 II. PERMIT INFORMATION: 1. Specify whether project is (check one): New Renewal X Modification Form SWU-101 Version 3.99 Page 1 of 4 2. If this application is being submitted as the result of a renewal or modification to an existing permit, list The existing permit number SW8001009 MOD and its issue date (if known) 9/2/03 3. Specify the type of project (check one): _ Low Density X High Density Redevelop General Permit Other 4. Additicaal Project Requirements (check applicable blanks): CAMA Major X Sedimentation/Erosion Control 404//401 Pen -nit NPDES Stormwater Information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748. III. PROJECT INFORMATION 1. In the space provided below, stummarize how stormwater will be treated. Also attach a detailed narrative (one to two pages) describing stormwater management for the project. wet detention 2. Stormwater runoff from this project drains to the Cape Fear River basin. 3. Total Project Area: 3.64 acres 5. How many drainage basins does the project have? 1 4. Project Built Upon Area: 71.0 %. 6. Complete the following information for each drainage area. If there are more than two drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. Receiving Stream Name Sm4h€��eek 5 c-,, , Receiving Stream Class C-SW Drainage Basin Area 3.64 Existing Impervious * Area - Proposed Impervious * Area 2.57 % Impervious* Area (total) 71% On -site Buildings 40,040 sf On -site Streets On -site Parking 69,182 sf On -site Sidewalks 486 Other on -site - Future 2;2-H sf Off -site Total: E=111,929 sf E= * Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas sidewalks, gravel areas, etc. Form SWU-101 Version 3.99 Page 2 of 4 7 How was the off -site impervious area listed above derived? IV. DEED RESTRICTIONS AND PROTECTIVE COVENANTS The following italicized deed restrictions and urotective covenants are required to be recorded for all subdivisions, outparcels and future development prior to the sale of any lot. If lot sizes vary significantly, a table listing each lot number, size and the allowable built -upon area for each lot must be provided as an attachment. 1. The following covenants are intended to ensure ongoing compliance with state stormwater management permit number as issued by the Division of Water Quality. These covenants may not be changed or deleted without the consent of the State. 2. No more than square feet of any lot shall be covered by structures of impervious materials. Impervious materials include asphalt, gravel, concrete, brick stone, slate or similar material but do not include wood decking or the water surface ofswimmingpools. 3. Swales shall not be filled in, piped or altered except as necessary to provide driveway crossings. 4. Built -upon area in excess of the permitted amount requires a state stormwater management permit modification prior to construction. 5. All permitted runoff from outparcels or future development shall be directed into the permitted stormwater control system. These connections to the stormwater control system shall be performed in a manner that maintains the integrity and performance of the system as permitted By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the applicable items required above, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. V. SUPPLEMENT FORMS The applicable state storinwater management permit supplement form(s) listed below must be submitted for each BMP specified for this project. Contact the Stonnwater and General Pen -nits Unit at (910) 733-5083 for the status and availability of these forms. Form SWU-102 Form SWU-103 Form SWU-104 Form SWU-105 Form SWU-106 Form SWU-107 Form SWU-108 Form SWU-109 Wet Detention Basin Supplement Infiltration Basil Supplement Low Density Supplement Curb Outlet System Supplement Off -Site System Supplement Underground Infiltration Trench Supplement Neuse River Basin Supplement Innovative Best Management Practice Supplement Form SWU-101 Version 3.99 Page 3 of 4 VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below. The complete application package should be submitted to the appropriate DWQ Regional Office. 1. Please indicate that you have provided the following required information by initialing in the space provided next to each item. Applicant's Initials • Original and one copy of the Stormwater Management Permit Application Form • One copy of the applicable Supplement Form(s) for each BMP • Permit application processing fee of $420 (payable to NCDENR) • Detailed narrative description of stormwater treatment/management • Two copies of plans and specifications, including: - Developinent/Project name - Engineer and firm - Legend - North arrow - Scale - Revision number and date - Mean high water line - Dimensioned property/project boundary - Location map with named streets or NCSR numbers - Original contours, proposed contours, spot elevations, finished floor elevations Details of roads, drainage features, collection systems, and stornwater control measures - Wetlands delineated, or a note on plans that none exist - Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations - Drainage areas delineated - Vegetated buffers (where required) VII. AGENT AUTHORIZATION If you wish to designate authority to another individual or firm so that they may provide information on your behalf, please complete this section. Designated agent (individual or firm): Tripe Engineering, P.C. Mailing Address: 419 Chestnut Street City: Wilmin on State: NC Zip: 28401 Phone: (910) 763-5100 Fax: 910) 763-5631 VIII. APPLICANT'S CERTIFICATION I, (print or type name of person listed in General Information, item 2) Richard Blacher , certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constricted in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of 15A NCAC 2H .1000. Signature: Date: Form SWU-101 Version 3.99 Page 4 of 4 Permit No. 9,6o / D Uq/411�� (to be provided by DN Q) State of North Carolina Department of Environment and Natural Resources Division of Water Quality S T ORM)WA'I ER MANAGEMENT PERMIT APPLICATION FORM WET DETENTION BASIN SUPPLEMENT This form may be photocopied for use as an original DWQ Stormwater Management Plan Review: A complete stonnwater management plan submittal includes a wet detention basin supplement for each basin, design calculations, plans and specifications showing all basin and outlet structure details, and a signed and notarized operation and maintenance agreement. I. PROJECT INFORMATION (please complete the following information): Project Name: Smith Creek Storage Facilities Inc. Contact Person: Richard Blacher Phone Number: (910) 799-5433 For projects with multiple basins, specify which basin this worksheet applies to: 1 elevations Basin Bottom Elevation 17.50 ft. Permanent Pool Elevation 24.00 ft. Temporary Pool Elevation 25.37 ft. (floor of the basin) (elevation of the orifice) (elevation of the discharge structure overflow) areas Permanent Pool Surface Area 6603 sq.ft. (water surface area at the orifice elevation) Drainage Area 3.64 ac. (on -site and off -site drainage to the basin) Impervious Area 2.57 ac. (on -site and off -site drainage to the basin) volumes Permanent Pool Volume 14;159_ cu.ft. (combined volume of main basin and forebay) Temporary Pool Volume 10,159 cu.ft. (volume detained above the permanent pool) Forebay Volume 3,018 cu.ft. (approximately 20% of total volume) Other parameters SA/DA' .034 (surface area to drainage area ratio from DWQ table) Diameter of Orifice 1.5_ in. (2 to 5 day temporary pool draw -down required Design Rainfall 1.0 in. Design TSS Removal2 90 % (minimum 85% required) Fonn SWU-102 Rev 3.99 Page 1 of 4 Footnotes: 1. When using the Division SA/DA tables, the correct SA/DA ratio for permanent pool sizing should be computed based upon the actual impervious % and permanent pool depth. Linear interpolation should be employed to determine the correct value for non- standard table entries. 2. In the 20 coastal counties, the requirement for a vegetative filter may be waived if the wet detention basin is designed to provide 90% TSS removal. The NCDENR BNIP manual provides design tables for both 85% TSS removal and 90% TSS removal. H. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices Manual (N.C. Department of Environment, Health and Natural Resources, February 1999) and Administrative Code Section: 15 A NCAC 2H .1008. Initial in the space provided to indicate the following design requirements have been met and supporting documentation is attached. If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below. If a requirement has not been met, attach justification. Applicants Initials a. The permanent pool depth is between 3 and 7 1/2 feet (required minimum of 3 feet). b. The forebay volume is approximately equal to 20% of the total basin volume. c. The temporary pool controls runoff from the design storm event. d. The temporary pool draws down in 2 to 5 days. e. If required, a 30-foot vegetative filter is provided at the outlet (include non -erosive flow calculations). f. The basin length to width ratio is greater than 3: 1. g. The basin side slopes above the permanent pool are no steeper than 3: 1. h. A submerged and vegetated perimeter shelf with a slope of 6:1 or less (show detail). i. Vegetative cover above the permanent pool elevation is specified. j. A trash rack or similar device is provided for both the overflow and orifice. k. A recorded drainage easement is provided for each basin including access to nearest right- of-way. 1. If the basin is used for sediment and erosion control during construction, clean out of the basin is specified to be performed prior to use as a wet detention basin A mechanism is specified which will drain the basin for maintenance or an emergency. Portable pump. III. WET DETENTION BASIN OPERATION AND MAINTENANCE AGREEMENT The wet detention basin system is defined as the wet detention basin, pretreatment including forebays and the vegetated filter if one is provided. This system (check one) ❑ does X does not incorporate a vegetated filter at the outlet. This system (check one) ❑ does X does not incorporate pretreatment other than a forebay. Form SWU-102 Rev 3.99 Page 2 of 4 Maintenance activities shall be performed as follows: After every significant runoff producing rainfall event and at least monthly: a. Inspect the wet detention system for sediment accumulation, erosion, trash accumulation, vegetated cover, and general condition. b. Check and clear the orifice of any obstructions such that drawdown of the temporary pool occurs within 2 to 5 days as designed. 2. Repair eroded areas immediately, re -seed as necessary to maintain good vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash as needed. 3. Inspect and repair the collection system (i.e. catch basins, piping, swales, riprap, etc.) quarterly to maintain proper functioning. 4. Remove accumulated sediment from the wet detention basin system semi-annually or when depth is reduced to 75% of the original design depth (see diagram below). Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i.e. stockpiling near a wet detention basin or stream, etc.). The measuring device used to determine the sediment elevation shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the permanent pool depth reads _4.875 feet in the main pond, the sediment shall be removed. When the permanent pool depth reads 4.875_ feet in the forebay, the sediment shall be removed. BASIN DIAGRAM (fill in the blanks) Permanent Pool Elevation 24.0 Sediment moval El. _19.12 J75 o - - - - - - - - - - - / Sediment Removal Elevation 19.12 75% Bottom evation 17.50 % -------------------------------------------- Bottom Elevation 17.50 f 25%q FOREBAY MAIN POND 5. Remove cattails and other indigenous wetland plants when they cover 50% of the basin surface. These plants shall be encouraged to grow along the vegetated shelf and forebay berm. 6. If the basin must be drained for an emergency or to perform maintenance, the flushing of sediment through the emergency drain shall be minimized to the maximum extent possible. Form SWU-102 Rev 3.99 Page 3 of 4 7. All components of the wet detention basin system shall be maintained in good working order. I acknowledge and agree by my signature below that I am responsible for the performance of the seven maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Print name. Richard Biacher Title: Owner Address: 5633 Market Street, Wilmington NC 28405 Phone Signal Date Note: The legally responsible party should not be a homeowners association iufless more than 50% of the lots have been sold and a resident of the subdivision has been named the president. I,�QAQ �6� a Notary Public for the State of North Carolina , County of do hereby certify that Richard Blacher personally appeared before me this day of , 200 and acknowledge the due execution of the forgoing wet detention basin maintenance requirements. Witness my hand and official seal, e �,,,` �G• w�n W • r�oT a gITBLIC CS 0VER SEAL My commission expires _ \ I I i 12-005 Form SWU-102 Rev 3.99 Page 4 of 4