Loading...
HomeMy WebLinkAboutSW8030620_CURRENT PERMIT_20080829STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW X 3 AMC DOC TYPE � CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE tis'�c�fld°� YYYYMMDD W ATF9 pG Tom Eakes, Owner Post Office Box 3373 Wilmington, NC 28405 Subject* PROJECT RETURN Stormwater Project No Tidewater Storage New Hanover County Dear Mr Eakes Michael F Easley, Governor William G Ross Jr , Secretary North Carolina Department of Environment and Natural Resources August 29, 2008 SW8 030620 Modification C0leLn H Sullins Director Division of Water Quality A review of your Stormwater Management Permit Application indicates that as of this date, information requested on June 9, 20004, has not been received in this Office within the stipulated timeframe Per the requirements of Section 1009 (c) of the Stormwater Management Rules, this Office is hereby returning the subject application as incomplete The $420 00 application fee has been forfeited and a new fee will need to be provided if you choose to resubmit this application in the future An inspection of the property will be conducted in the near future You are reminded that any construction of impervious surfaces on the property prior to receipt of a permit will constitute a violation of 15A NCAC 2H 1000 and may result in the assessment of civil penalties By copy of this letter to the local Building Inspector, this Office is requesting that they consider withholding the building permits and Certificates of Occupancy for this project pending issuance of a Stormwater Management Permit If you have any questions concerning this matter, please contact Rhonda Hall or me at (910) 796-7215 SlIgerely, r1L� Effward Beck Regional Supervisor Surface Water Protection Section ENBlrbh S1WQSISTORMWATERIRETURN1030620MOD aug08 cc Phillip G Tripp, P E, Tripp Engineering, P C New Hanover County Inspections Beth E Wetherill, New Hanover County Engineering City of Wilmington Development Services Rhonda Hall Wilmington Regional Office Central Files N 'O Carolina Naturally North Carolina Division of Water Quality 127 Cardinal Dnve Extension Wilmington, NC 28405 Phone (910) 796-7215 Customer Service Wilmington Regional Office ]ntemet www newater uallt or Fax (910) 350-2004 1 977-623-6748 An Equal OpportumtylAtfirmative Action Employer— 50% Recycled110% Post Consumer Paper F WATF Michael F Easley, Governor �aQ RQ William G Ross Jr, Secretary t' �O G North Carolina Department of Environment and Natural Resources yAlan W Klimek, P E ,Director .� Division of Water Quality Coleen H Sullins, Deputy Director Division of Water Quality June 9, 2004 Mr Tom Eakes, Owner PO Box 3373 «Vilmington, NC 28405 Subject REQUEST FOR ADDITIONAL INFORMATION Stormwater Project No SW8 030620 Mod Tidewater Storage New Hanover County Dear Mr Eakes The Wilmington Regional Office received a Stormw ater Management Permit Application for Tidewater Storage on March 19, 2004 A preliminary review of that information has determined that the application is not complete The following information is needed to continue the stormwater reNzew The narrative and application indicates that the existing tract is 1 31 acres I believe that this should be 1 34 acres versus 131 acres 2 Please verify the length of the trench on the supplement Some discrepancies exist between scaling and what is written 3 The trench drainage detail on the drawings only show a 16 foot wide trench Ho« e,. er, the drawing C-1 shows tnvo 16 foot trenches and two 20 foot trenches Please add an additional trench drainage detail to show the 20 foot trench 4 Please update site data on the drawings to correspond with the application and hydraulic calculations Please % enfy the maximum volume provided of the infiltration trench I calculate the maximum volume provided to be approximately 9,500 cubic feet versus 10,789 cubic feet My calculations are based on 426 linear feet of 8" pipe and 731 linear feet of 12" pipe (as scaled from the plans) 6 It appear that the overflow from the infiltration trench will drain into the parking lot w ith no way to be released from the parking lot Is that the intent9 Please note that this request for additional information is in response to a preliminary reN lew The requested information should be received by this Office prior to June 15, 2004, or the application will be returned as incomplete The return of a project will necessitate resubmittal of all required items, including the application fee N C Division of Water Quality 127 Cardinal Dnve Extension (910) 395-3900 Wilmington Regional Office Wilmington NC 28405 (910) 350-2004 Fax Customer 5ennce 1 800 623-7748 MIR Mr Tom Eakes Page 2 Tune 9, 2004 If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter The request must indicate the date by which you expect to submit the required information The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215 1 and is subject to enforcement action pursuant to NCGS 143-215 6A Please reference the State assigned project number on all correspondence Any original documents that need to be revised have been sent to the engineer or agent All original documents must be returned or new originals must be provided Copies are not acceptable If you have any questions concerning this matter please feel free to call me at (910) 395-3900 Sincerely, Rhonda Hall Environmental Engineer RSS/ rbh S 1WQSISTORMWATIADDINFO120041030620 jun04 cc Rhonda Hall Phillip G Tripp, P E State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original I GENERAL INFORMATION I Applicants name (specify the name of the corporation, individual, etc who owns the project) 2 Print Owner/Signing Official's name and title (person legally responsible for facility and compliance) Tom Eakes, Owner 3 Mailing Address for person listed in item 2 above P O Box 3373 City Wilmington T State NC Zip 28405 Telephone Number 763-7000 4 Project Name (subdivision, facility, or establishment name — should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc ) _ Tidewater Storage - 5 Location of Project (street address) 410 Cando Street City Wilmington County New Hanover 6 Directions to project (from nearest major intersection) At3orox 10001f south of the intersection of Hwy 132 and Martin Luther King Jr Parkway 7 Latitude N 340 15' 00" Longitude W 770 53' 00" of project 8 Contact person who can answer questions about the project Name Phillip TrippTelephone Number 910-763-5100 II PERMIT INFORMATION 1 Specify whether project is (check one) _ _ New Renewal X Modification Form SVVU-101 Version 3 99 Paget of4 2 If this application is being submitted as the result of a renewal or modification to an existing permit, list The existing permit number SW8 030620 and its issue date (if known) 1/29/04 3 Specify the type of project (check one) Low Density X High Density Redevelop General Permit Other 4 Additional Project Requirements (check applicable blanks) CAMA Major X Sedimentation/Erosion Control 404H401 Permit NPDES Stormwater Information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748 III PROJECT INFORMATION 1 In the space provided below, summarize how stormwater will be treated Also attach a detailed narrative (one to two pages) describing stormwater management for the project under round infiltrations stem 2 Stormwater runoff from this project drams to the Cape Fear River basin -)C\ 3 Total Project Area 1 31 acres 4 Project Built Upon Area--85-57 % 5 How many drainage basins does the project have9 1 6 Complete the following information for each drainage area If there are more than two drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below B'N$�. 'T }x4 asin" infor� att n 1, Yb.dc«-tyY 6_No !z a. e iS+P6i lef '� 7seT f Drama e3$asi 1 x 5 "n 3e .844?tt+`P' t� e 14^ �4 n !a�' �:�"' gY61f Drainage Bas 1 r Es r't'# 4%'°ztfs» 3 ise �rr Receiving Stream Name Smith Creek Receiving Stream Class C-SW Drainage Basin Area 1 31 ac Existing Impervious * Area - Proposed Impervious * Area 1 05 ac % Impervious* Area (total) 79% ' Impef ous * Surface'A�rea brainage Basin ° Drainage B`asmf2� �"1k On -site Buildings 23,100 sf On -site Streets - On -site Parking 22,527 sf On -site Sidewalks 130 sf Other on -site - Off -site Total E=45,757 sf E= * Impervious area is defined as the built upon area including, but not limited to buildings roads, pat king areas sidewalks, gravel areas, etc Form SWU-101 Version 3 99 Page 2 of 4 How was the off -site impervious area listed above derived? NA IV DEED RESTRICTIONS AND PROTECTIVE COVENANTS The following italicized deed restrictions and protective covenants are required to be recorded for all subdivisions, outparcels and future development prior to the sale of any lot If lot sizes vary significantly, a table listing each lot number, size and the allowable built -upon area for each lot must be provided as an attachment 1 The following covenants are intended to ensure ongoing compliance with state stormwater management permit number SW80030620 as issued by the Division of Water Quality These covenants may not be changed or deleted without the consent of the State 2 No more than square feet of any lot shall be covered by structures of impervious materials Impervious materials include asphalt, gravel, concrete, brick, stone, slate or similar material but do not include wood decking or the water surface of swimming pools 3 Swales shall not be filled in, piped or altered except as necessary to provide driveway crossings 4 Built -upon area in excess of the permitted amount requires a state stormwater management permit mod canon prior to construction S All permitted runofffrom outparcels or future development shall be directed into the permitted stormwater control system These connections to the stormwater control system shall be performed in a manner that maintains the integrity and performance of the system as permitted By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the applicable items required above, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot V SUPPLEMENT FORMS The applicable state stormwater management permit supplement form(s) listed below must be submitted for each BMP specified for this project Contact the Stormwater and General Permits Unit at (910) 733-5083 for the status and availability of these forms Form SWU-102 Wet Detention Basin Supplement Form SWU-103 Infiltration Basin Supplement Form SWU-104 Low Density Supplement Form SWU-105 Curb Outlet System Supplement Form SWU-106 Off -Site System Supplement Form SWU-107 Underground Infiltration Trench Supplement Form SWU-108 Neuse River Bann Supplement Form SWU-109 Innovative Best Management Practice Supplement Form SWU-101 Version 3 99 Page 3 of VI SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ) A complete package includes all of the items listed below The complete application package should be submitted to the appropriate DWQ Regional Office 1 Please indicate that you have provided the following required information by initialing in the space provided next to each item Applicant's Initials • Original and one copy of the Stormwater Management Permit Application Form A4:±_ • One copy of the applicable Supplement Form(s) for each BMP 4A::E • Permit application processing fee of $420 (payable to NCDENR) • Detailed narrative description of stormwater treatment/management • Two copies of plans and specifications, including /Ldfi - Development/Project name - Engineer and firm - Legend - North arrow - Scale - Revision number and date - Mean high water line - Dimensioned property/project boundary - Location map with named streets or NCSR numbers - Original contours, proposed contours, spot elevations, finished floor elevations - Details of roads, drainage features, collection systems, and stormwater control measures - Wetlands delineated, or a note on plans that none exist - Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations - Drainage areas delineated - Vegetated buffers (where required) VII. AGENT AUTHORIZATION If you wish to designate authority to another individual or firm so that they may provide information on your behalf, please complete this section Designated agent (individual or firm) Tripp Engineering, P C Mailing Address 419 Chestnut Street City _ Wilmington State NC Zip 28401 Phone 910 763-5100 VIII APPLICANT'S CERTIFICATION Fax 910 763-5631 I, (print or type name of person listed in General Information, item 2) Tom Eakes , certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constru d in conformance with the approved plans, that the required deed restrictions and protective coven 0 e recorded, and that the proposed project complies with the requirements of 15A NCAC 2H 1000 n Signature - Date 11-7 C� Form SWU-101 Version 3 99 Page 4 of 4 Permit No ���.Io��� (to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied far use ac an original DWQ Stormwater Management Plan Review A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details I PROJECT INFORMATION Project Name Tidewater Storage Contact Person Phillip TrippPhone Number 910 763-5100 For projects with multiple infiltration systems, a supplement form must be completed for each system This worksheet applies to Trench 1 in Drainage Area 1 (from plans) (from Form SWU-101) II. DESIGN INFORMATION (attach supporting calculations/documentation) Soils Report Summary (based upon an actual field invevtigation and soil boringv) Soil Type Baymeade (fine sand.. 1�) Infiltration Rate 48 (�Dor cf/hr/sf (circle appropriate units) SHWT Elevation Trench Design Parameters Design Volume Design Storm Drawdown Time Perforated Pipe Size Perforated Pipe Length No Observation Wells Stone Type (if used) Stone Void Ratio 283 fmsl {Seasonal High Water Table elevation) 7403 c f 20 inch event (1 S inch event for SA waters, 1 inch event far others) 05 _ days hours 8"/12" inch diameter 492 / 735 ft #57 crushed granite 04 Trench Elevations (in feet mean sea level) Bottom Elevation 303 finsl (may be required on a case -by -care basis) Storage/Overflow Elevation 32 3 fmsl SWU-107 Rev 3 99 Page 1 of 4 s Observation well(s) are provided (case -by -case basis) t Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans RIL_ u A benchmark for checking sediment accumulation is provided IV. UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition 2 Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth Restore depth to original design depth without over -excavating Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed 4 The water level in any monitoring wells will be recorded after a 1 inch rainfall event and at least once a month Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately 5 If DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H 1000 must be designed, approved and constructed 6 Remove accumulated sediment from the infiltration system annually or when depth in the unit is reduced to 75% of the original design depth The system shall be restored to the original design depth without over -excavating Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i e stockpiling near a stormwater treatment device or stream, etc ) A benchmark shall be established in the infiltration system The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken The measuring device used to determine the depth at the benchmark shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments When the depth at the benchmark reads 0.75 , the accumulated sediment shall be removed from the system. SWU-107 Rev 3 99 Page 3 of I acknowledge and agree by my signature below that I am responsible for maintaining the stormwater collection system in accordance with the six maintenance procedures listed above I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party Print Name and Title Tom Eakes Owner Address P 0 Box 3373 Wilmington, NC Phone Phone Signature Date 3 - l % r d Note: The legally responsible parry should not be a homeowners association unless more than 50% of the lots have been %old and a resident of the subdivision has bee named the president 1, Della C Baird , a Notary Public for the State of North Carolina , County of Pender , do hereby certify that Tom_ Eakes - personally appeared before me this k day of KAaq_6, , 2004 , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements Witness my hand and official seat, 0. 1 NOTARY E'UBL►O O %,FA COIiN\����� '00 iu11110, SEAL My commission expires October 15, 2006 SWU-107 Rev 3 99 Page 4 of VgA7zR Michael F Easley, Governor OF QG William G Ross Jr, Secretary (t North Carolina Department of Environment and Natural Resources r > y Alan W Klimek, P E ,Director Division of Water Quality January 28, 2004 Mr Tom Eakes P O Box 3373 Wilmington, NC 28405 Coleen H Sullins Deputy Director Division of Water Quality Subject Permit No SW8 030620 Tidewater Storage High Density Stormwater Project New Hanover County Dear Mr Eakes The Wilmington Regional Office received a complete Stormwater Management Permit Application for Tidewater Storage on January 28, 2004 Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H 1000 We are forwarding Permit No SW8 030620 dated January 28, 2004, for the construction of Tidewater Storage This permit shall be effective from the date of issuance until January 28, 2014, and shall be subject to the conditions and limitations as specified therein Please pay special attention to the Operation and Maintenance requirements in this permit Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit This request must be in the form df a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P O Drawer 27447, Raleigh, NC 27611-7447 Unless such demands are made this permit shall be final and binding If you have any questions, or need additional information concerning this matter, please contact Laurie Munn, or me at (910) 395-3900 Sincerely, Rick Shiver Water Quality Regional Supervisor RSS/ Ism S 1WQSISTORMWATIPERMIT1030620 jan04 cc Charles Cazier New Hanover County Building Inspections Beth E Wetherill, New Hanover County Engmeenng Laurie Munn Wilmington Regional Office Central Files N C Divtston of Water Quality 127 Cardinal Drive Extension (910) 395-3900 Customer Service SM Wilmington Regional Office Wilmington, NC 28405 (910) 350-2004 Fax 1 800 623-7748 NMENER State Stormwater Management Systems Permit No SW8 030620 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Mr Tom Eakes Tidewater Storage New Hanover County FOR THE construction, operation and maintenance of an infiltration trench in compliance with the provisions of 15A NCAC 2H 1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit + This permit shall be effective from the date of issuance until January 28, 2014, and shall be subject to the following specified conditions and limitations I. DESIGN STANDARDS 1 Tlus permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data 2 This stormwater system has been approved for the management of stormwater runoff as described on page 3 of this permit, the Project Data Sheet The stormwater control has been designed to handle the runoff from 45,978 square feet of impervious area This system must be operated with a vegetated filter 3 The tract will be limited to the amount of built -upon area indicated on page 3 of this — permit, and per approved plans 4 All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans 5 The runoff from all built -upon area within the permitted drainage area of this project must be directed into the permitted stormwater control system A permit modification must be submitted and approved prior to the construction of additional built -upon area from outside of the approved drainage area 2 State Stormwater Management Systems Permit No SW8 030620 DIVISION OF WATER QUALITY PROJECT DESIGN DATA SHEET Project Name Permit Number Location Applicant Mailing Address Application Date Receiving Stream/River Basin Stream Index Number Classification of Water Body Drainage .Area, acres Onsite, sq ft Offsite, sq ft Total Impervious Surfaces, sq ft Trench Dimensions, LxWxH, feet Piping (8" perforated piping) Piping (12" perforated piping) Trench Bottom Elevation, FMSL Permitted Storage Volume, W Temporary Storage EIevation, FMSL Type of Soil Expected Infiltration Rate SHWT Elevation, FMSL Time to draw down Tidewater Storage SW8 030620 New Hanover County Mr Tom Eakes P O Box 3373 Wilmington, NC 28405 January 28, 2004 Smith Creek / Cape Fear 18-74-63 "C Sw" 131 58,370 none 45,978 800x 15x2 375 linear feet 795*,Iinear feet 303 10,053 323 Baymeade (fine sandy loam) 48 0 in/hr 283 c 1 hour 3 State Stormwater Management Systems Permit No SW8 030620 II. SCHEDULE OF COMPLIANCE 1 The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface 2 During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately 3 The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to a Semiannual scheduled inspections (every 6 months) b Sediment removal c Mowing and revegetation of slopes and the vegetated filter d Immediate repair of eroded areas e Maintenance of all slopes in accordance with approved plans and specifications f Debris removal and unclogging of outlet structure, orifice device, flow spreader, catch basins and piping g Access to the outlet structure must be available at all times 4 Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ The records will indicate the date, activity, name of person performing the work and what actions were taken The facilities shall be constructed as shown on the approved plans This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data 6 Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system instal ed certifying that the permitted facility has been installed in accordance with this permit, t e approved plans and specifications, and other supporting documentation Any deviations from the approved plans and specifications must be noted on the Certification A modification may be required for those deviations 7 If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility 8 The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below a Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc b Project name change c Transfer of ownership d Redesign or addition to the approved amount of built -upon area or to the drainage area e Further subdivision, acquisition, or sale of all or part of the project area The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought f Filling in, altering, or piping of any vegetative conveyance shown on the approved plan 4 State Stormwater Management Systems Permit No SW8 030620 9 The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction If the proposed BUA exceeds the amount permitted under this permit, a modification to the permit must be submitted and approved prior to construction 10 A copy of the approved plans and specifications shall be maintained on file by the Permrttee for a minimum of ten years from the date of the completion of construction 11 At least 30 days prior to the sale or lease of any portion of the property, the permittee shall notify DWQ and provide the name, mailing address and phone number of the purchaser or leasee An access/maintenance easement to the stormwater facilities shall be granted in favor of the permittee if access to the stormwater facilities will be restricted by the sale or lease of any portion of the property 12 The permittee must maintain compliance with the proposed built -upon area and ensure that the runoff from all the built -upon is directed into the permitted system 13 The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made 14 The permittee must maintain the current permitted drainage area No additional runoff from outside of the permitted drainage area boundary may enter the permitted stormwater facilities without first applying for and receiving a permit modification III. GENERAL CONDITIONS This permit is not transferable except after notice to and approval by the Director In the event of a change of ownership, or a name change, the permittee must submit a formal permit transfer request to the Division of Water Quality, accompanied by a completed name/ownership change form, documentation from the parties involved, and other supporting materials as maybe appropnate The approval of this request will be considered on its merits and may or may not be approved The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request 2 Failure to abide by the conditions and limitations contained in this pennit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215 6A to 143-215 6C 3 The issuance of this permit does not preclude the Permrttee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction 4 In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement Y stormwater management systems 5 The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility 6 The permit may be modified, revoked and reissued or terminated for cause The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition 5 State Stormwater Management Systems Permit No SW8 030620 7 Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual 8 Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit 9 The permittee shall notify the Division any name, ownership or mailing address changes within 30 days Permit issued this the 28th day of January 2004 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Alan W Klimek, P E , Director (� Division of Water Quality By Authority of the Environmental Management Commission 0 State Stormwater Management Systems Permit No SW8 030620 Tidewater Storage Stormwater Permit No SW8 030620 New Hanover County Designer's Certification I, , as a duly registered in the State of North Carolina, having been authonzed to observe (periodically/weekly/full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications The checklist of items on page 2 of this form is included in the Certification Noted deviations from approved plans and specification Signature Registration Number Date + 11 SEAL 7 �A State Stormwater Management Systems Permit No SW8 030620 Certification Requirements 1 The drainage area to the system contains approximately the permitted acreage 2 The drainage area to the system contains no more than the permitted amount of built -upon area 3 All the built -upon area associated with the project is graded such that the runoff drams to the system 4 The outlet/bypass structure elevations are per the approved plan 5 The outlet structure is located per the approved plans 6 Trash rack is provided on the outlet/bypass structure 7 All slopes are grassed with permanent vegetation 8 Vegetated slopes are no steeper than 3 1 9 The inlets are located per the approved plans and do not cause short-circuiting of the system 10 The permitted amounts of surface area and/or volume have been provided 11 Required drawdown devices are correctly sized per the approved plans 12 All required design depths are provided 13 All required parts of the system are provided, such as a vegetated shelf, and a forebay 14 The overall dimensions of the system, as shown on the approved plans, are provided cc NCDENR-DWQ Regional Office New Hanover County Building Inspections E:3 , ,, f E , " I' e " ., OFFICE USEONLY 1 "s • r ih 1 ; ?q, , ,1;,4 Date Received Fee Paid Permit Number So 40 State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original I GENERAL INFORMATION Applicants name (specify the name of the corporation, individual, etc who owns the project) Tom Eakes 2 Print Owner/Signing Official's name and title (person legally responsible for facility and compliance) Tom Eakes, Owner 3 Mailing Address for person listed in item 2 above P O Box 3373 City Wilmington State NC Zip 28405 Telephone Number 763-7000 4 Project Name (subdivision, facility, or establishment name — should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc ) Tidewater Storage 5 Location of Project (street address) 410 Cando Street City Wilmington T County New Hanover 6 Directions to project (from nearest major intersection) —Apl2rox 1000 if south of the intersection of Hwy 132 and Martin Luther King Jr Parkway 7 Latitude N 340 15' 00" _ Longitude W 770 53' 00" of project S Contact person who can answer questions about the project Name Phillip-Tril2p 1. Telephone Number 910-763-5100 H. PERMIT INFORMATION- 1 Specify whether project is (check one) X New Renewal Modification Form SWU-101 Version 3 99 Page 1 of 4 2 If this application is being submitted as the result of a renewal or modification to an existing permit, list The existing permit number NA and its issue date (if known) 3 Specify the type of project (check one) Low Density X High Density Redevelop General Permit Other 4 Additional Project Requirements (check applicable blanks) CAMA Major X Sedimentation/Erosion Control 404//401 Permit NPDES Stormwater Information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748 M. PROJECT INFORMATION 1 In the space provided below, summarize how stormwater will be treated Also attach a detailed narrative (one to two pages) describing stormwater management for the project underground infiltrations stem 2 Stormwater runoff from this project drains to the Cape Fear River basin 3 Total Project Area 131 acres 4 Project Built Upon Area 8057 % 5 How many drainage basins does the project have? 1 6 Complete the following information for each drainage area If there are more than two drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below SasinInfo`rmatiom ''1 �}, ,, ��i,, i��c 5t �A3Y 3Ak:f t skwtltllP§ ifb vY]Y E�� I i i d iY� 1�'°dA f au fl r .�av i :7y� D'ramageBasmla i� 3 a!"!3l O: »f:tuu�Mi Ri" E!4 ieit uete93d3i8 i �a F%H 1 sh i { At� 3Sii3 Y8 Yide3Ni��t�Fe %PFfE ill t i 8 E P `t Ae S Y �i 3 Receiving Stream Name Smith Creek Receiving Stream Class C-SW Drainage Basin Area 1 31 ac Existing Impervious * Area - Proposed Impervious * Area 1 06 ac % Impervious* Area (total) 80 57% Impervious * Sui faceArea ` A q!E D°P3?f3nBnli {,4AT:f�89n3!l.i4xti-F u 3 t it3�iii3� �� �1'i '� ��" "' Basin 1`I Fa �� g, Dra�nag�e+ _, r d2+ i 1A'i(4iE eElMrev¢h Hf 11 a9;f'd a'1 t On -site Buildings 20,675 sf On -site Streets - On -site Parking 25,215 sf On -site Sidewalks 88 sf Other on -site - Off site - Total E=45,978 sf Z= * Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas sidewalks, gravel areas, etc Form SWU-101 Version 3 99 Paget of How was the off -site impervious area listed above derived? NA IV, DEED RESTRICTIONS AND PROTECTIVE COVENANTS I he following italicized deed restrictions and protective covenants are required to be recorded for all subdivisions, outparcels and future development prior to the sale of any lot If lot sizes vary significantly, a table listing each lot number, size and the allowable built -upon area for each lot must be provided as an attachment The following covenants are intended to ensure ongoing compliance with state stormwater management permit number cis issued by the Divivion of Water Quality These covenants may not be changed or deleted without the consent of the State 2 No more than square feet of any lot shall be covered by structures of impervious materials Impervious materials include asphalt, gravel, concrete, brick stone, slate or similar material but do not include wood decking or the water surface ofswimmtngpools 3 Swales shall not be filled in, piped or altered except as necessary to provide driveway crossings 4 Built --upon area in excess of the permitted amount requires a state stormwater management permit modification prior to constrwhon 5 All permitted runoff from outparcels or future development shall be directed into the permitted stornnaater control system These connections to the stormwater control system shall be performed in a manner that maintains the integrity and performance of the sys lem as permitted By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the applicable items required above, that the covenants will be binding on all parties and persons claumng under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot V. SUPPLEMENT FORMS the applicable state stormwater management permit supplement form(s) listed below must be submitted for each BMP specified for this project Contact the Stormwater and General Permits Unit at (910) 733-5083 for the status and availability of these forms Form SWU-102 Wet Detention Basin Supplement Form SWU-103 Infiltration Basin Supplement Form SWU-104 Low Density Supplement Form SWU-105 Curb Outlet System Supplement Form SWU-106 Off -Site System Supplement Form SWU-107 Underground Infiltration Trench Supplement Form SWU-108 Neuse River Basin Supplement Form SWU-109 Innovative Best Management Practice Supplement Form SWU-101 Version 3 99 Page 3 of VI SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ) A complete package includes all of the items listed below. The complete application package should be submitted to the appropriate DWQ Regional Office I Please indicate that you have provided the following required information by initialing in the space provided next to each item Applicant's Initials • Original and one copy of the Stormwater Management Permit Application Form Cam- _ • One copy of the applicable Supplement Form(s) for each BMP cyc • Permit application processing fee of $420 (payable to NCDENR) CAX • Detailed narrative description of stormwater treatment/management 01XI • Two copies of plans and specifications, including cpC. Development/Project name Engineer and firm Legend North arrow Scale Revision number and date Mean high water line Dimensioned property/project boundary Location map with named streets or NCSR numbers Original contours, proposed contours, spot elevations, finished floor elevations Details of roads, drainage features, collection systems, and stormwater control measures Wetlands delineated, or a note on plans that none exist Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations Drainage areas delineated Vegetated buffers (where required) V11 AGENT AUTHORIZATION If you wish to designate authority to another individual or firm so that they may provide information on your behalf, please complete this section Designated agent (individual or firm) Tnnpnn mpg, P C__ Mailing Address 419 Chestnut Street City Wilmm tg on _ State NC Zip 28401 Phone 9E0 7b3-5100 Fax (910)763-5631 Vlll APPLICANT'S CERTIFICATION I, (print or type name of person listed in General Information, item 2) Tom Eakes , certify that the information included on this permit application form is, to the best of my knowledge, correct and that the protect will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of 15A NCAC 2H 1000 Signature Date 6 "Ig 'D Form SWU-101 Version 3 99 Page 4 of 4 Permit No SWI? 0� (to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied for use as an original DWQ Stormwater Management Plan Review A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details I PROJECT INFORMATION Project Name Tidewater Storage Contact Person Phillip Tripp Phone Number 910 763-5100 t For projects with multiple infiltration systems, a supplement form must be completed for each system This worksheet applies to Trench l in Drainage Area 1 (from plans) (from Form SWU-101) II DESIGN INFORMATION (attach supporting calculations/documentation) Soils Report Summary (based upon an actual field investigation and soil borings) Soil Type Baymeade (fine sandy loam) Infiltration Rate 4$ Q�or cf/hr/sf (circle appropriate units) SHWT Elevation 28 3-- fmsl (Seasonal High Water Table elevation) Trench Design Parameters Design Volume 7578 c f Design Storm Drawdown Time Perforated Pipe Size Perforated Pipe Length No Observation Wells Stone Type (if used) Stone Void Ratio 2 0_ inch event (1 5 inch event for SA waters, 1 inch event for others) 05 days hours 891/12" inch diameter 375 / 795 ft 0 #57 crushed granite _ 04 Trench Elevations (infeet mean sea level) Bottom Elevation 303 fmsl Storage/Overflow Elevation 32 3 fmsl (may be required on a case -by -case basis) SWU-107 Rev 3 99 Page] of 4 Jan 28, 04 02: 18p Phillip Tripp 310-763-5631 P- 2 Trench Dimensions Height 2 ft Length 800 ft Width 15 ft Volume Provided _ 10 052 95_ cu ft III REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N C Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section 15 A NCAC 2H 1008 Initial in the space provided to indicate the following design requirements have been met and supporting documentation is attached If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below Attach justification if a requirement has not been met Applicants Initials a System is located 50 feet from class SA waters and 30 feet from other surface waters L.,ae b System is located at least 100 feet from water supply wells c Bottom of system is at least 2 feet above the seasonal high water table d Bottom of the system is 3 feet above any bedrock or impervious soil horizon _ NA „ _ e Off-line system, runoff is excess of the design volume bypasses the system (bypass detail provided) f System is designed to draw down the design storiage volume to the proposed bottom elevation under seasonal lugh water conditions within five days based upon infiltration through the bottom only (a hydrogeologic evaluation may be required) g Soils have a minimum hydraulic conductivity of 0 52 inches per hour [M _ h System is not sites on or in fill material or DWQ approval has been obtained i Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized I System is sized to take into account the runoff at the ultimate built -out potential from all surfaces draining to the system, including any off -site drainage k System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way 1 System captures and infiltrates the runoff from the first 10 inch of rainfall (1 5 inch event for areas draining to SA waters) C- in Drainage area for the device is less than 5 acres t [>� n A pretreatment deti ice ( filter strip, grassed swale, sediment trap, etc ) is provided o Trench bottom is covered with a layer of clean sand to an average depth of 4 inches _ p Sides of infiltration trench are lined with geotextile fabric q Rock used is free of fines (washed stone) and has large void ratio r Side to bottom ratio is less than 4 1 SWU-107 Rev 3 99 Page 2 of s Observation well(s) are provided (case -by -case basis) t Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans u A benchmark for checking sediment accumulation is provided IV UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT 1 After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition 2 Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth Restore depth to original design depth without over -excavating Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed 4 The water level in any monitoring wells will be recorded after a 1 inch rainfall event and at least once a month Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately 5 If DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H 1000 must be designed, approved and constructed 6 Remove accumulated sediment from the infiltration system annually or when depth in the unit is reduced to 75% of the original design depth The system shall be restored to the original design depth without over -excavating Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i e stockpiling near a stormwater treatment device or stream, etc ) A benchmark shall be established in the infiltration system The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken The measuring device used to determine the depth at the benchmark shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments When the depth at the benchmark reads 0.75 , the accumulated sediment shall be removed from the system. S W U-107 Rev 3 99 Page 3 of 4 t acknowledge and agree by my signature below that I am responsible for maintaining the stormwater collection system in accordance with the six maintenance procedures listed above I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party Print Name and Title Tom Eakes, Owner Address P O Box 3373 Wilmin ton NC Phone 910-763-7000 Phone Signature Date 6 / Z - o Note: The legally responsible party should not be a homeowners association unless more than 50% of the loly have been sold and a resident of the subdivi6ion has bee named the president 1, Della C Baird , a Notary Public for the State of —North Carolina_ , County of Pender , do hereby certify that Tom Eakes personally appeared before me this 2 day of j'L4W_ 2003 , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements Witness my hand and official sea], ,, e f C. NOTAO j, O US LIC � z C I ou I 0,11\\ F� SEAL My commission expires October 15, 2006 SWU-107 Rev 3 99 Page 4 of