Loading...
HomeMy WebLinkAboutSW7951203_APPROVED PLANS_19960104STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. Sw 793 DOC TYPE ❑ CURRENT PERMIT 60 APPROVED PLANS ❑ HISTORICAL FILE DOC DATE 1pd YYYYMMDD i 'V. 20' FOOD LION I ENTRY VESTIBULE 12" HIGH 14' WALK LETTERSi NO PARKING NO PARKM PARM PICK-W PARCM PICK-W 30' 4' SOLID YELLOW OR WHITE LINE 41-me 3' LONG ARROW (TYP.) 41�- — - -♦I - -- - - - - - - - - - - - -- -2- m? PARCEL PICK-UP DETAILS NOT TO SCALE 20' HANDICAP SIGN (ONE SIDE) E ONE STD, H/C SYMBOL ON EACH kRKING SPACE W/ RAFFIC PAINT I L NJ HANDICAP SPACE TYPE "B" 90' SPACES TYPE "B" 90* HANDICAP TYPICAL 130* PARKING PETALS NOT TO SCALE 0 FA R/W �sO_l —10' DRAINAGE & UTILITY EASEMENT TRACT %� -(FUTURE DEVELOPMENT) I lhag) 5o17qb-1z-o3 LEGEND' POWER LINE 51TE OPP POWER POLE mo. TRAFFIC FLOW DIRECTION CONCRETE AREA GREENFIELD BLVD 10' "N 0 GENE,,' 4, JACK60N 5TOFRMWATER % FR0f=EfRTY 01w POWER LINE -DETENTION POND 8) BACK OF 24" C&G _T 7_ 1 T F-7 -7 7­7-f T 7 7 —1— 22' 22 spaces 15 future spaces —11110. 24' 30' 13 spaces X, 0 10' DRAINAGE & 0. UTILITY EASEMENT 15'X30' SHOPS CL DUMPSTER 400 S.F. n (n PAD 9 spaces \.600" 4 01 LD _j so - 0 —ty -_ . 16 spaces Cq RAMP 24' X 186,0" 4 I I I` \ — I <1 TRANSFORMER PAD 15 spaces 20 4 ol� 20 15 spaces SEE DETAIL .,FOR I A 64' PARCEL 10)CK—UP a 24' STRIPING/ e I 15 spaces Pp FOOD LION 7 29-95 DB 20 20 JL -L 4 .4 GENE A. J,4GK50N 9 __7TYP 15 spaces PROPERTY' PROPERTY'to 24 C• 750spaces 00 P FO 00 FUTURE EXPANSION AREA 30' 1126'1 1 120 1 1 25' U) 29' 8,400 S.F. 1 210'0" 13' Typ. d ------- 77RAMPI I SHOPS 0 20 2,400 S.F. H/C SIG N---// 60'0" (TYP.) 15 spaces 7 spaces A 40-- 10' DRAINAGE 10' DRAINAGE & 65, 20' P 24 UTILITY EASEMENT 1 UTILITY EASEMENT 0N -moo- 14 spaces 1 0' X 20' 20' M.B.L. FOOD LION —71 1 1 25' SIGN EASEMENT 25 154.00' ------- -- ------ 05v5716' BACK 161F-Z -5­ jo 77� -- — ---------- - ----- -------------- ,;a-241! --- 0&G - --------------- -0" —6— L 20' LONG X 18" WIDE 20LONG X 18" WIDE PAINTED WHITE LINE PAINTED WHITE LINE 20' LONG X 18" WIC PAINTED WHITE LINE REV.-CAS-10/09/95-GEN. REV. PER OWNERS REVIEW GREENFIELD 5OULEVARD (N.C.5.R. 114ro) 60, R/w 4­1 JL _J Sol. w 9 aois ems. X 'A. U 0 ? 2 A125 100 0 SHEET I OF 5 FIELD BOOK: DISK NAME: ACAD 256B FILENAME: GFSC-LP.DWG _7LF JOB NO.: C950404-G1747 P VCINTr SKETCH I NOT TO SCALE I TRACT DATA PHASE 1 FOOD LION 32,970 S,F- PROPOSED SHOPS 4,800 S.F. TOTAL LEASE AREA 37,770 S.F. PARKING @ 4.53/1000 S.F. 171 SPACES PHASE 2 FUTURE FOOD LION EXPANSION 8,400 S.F. SHOPS DELETED @ EXPANSION (2,400) S.F. TOTAL FUTURE LEASE AREA 43,770S.F. TOTAL FUTURE PARKING 190 SPACES STANDARD ALUMINUM SIGN MEETING REQUIREMENTS OF A.D.A. AND/OR LOCAL HANDICAPPED PARKING CODE 1" HIGH WHITE LETTERS INTERNATIONAL HANDICAPPED SYMBOL ;11Ujm;Tff4L1f(ia9C"k F INSTALL ADDITIONAL SIGN WHERE APPLICABLE 2"X2* STL. TUBE. EXTEND INTO CONC, FILLED PIPE 2*-0"- 6" DiA. STD, STL. PIPE FILLED WITH CONCRETE PAVEMENT POUT PARKING ONLY TOW -AWAY ZONE off-% MAMUM FINE s5w.00 VAN --ACCESSIBLE 11 2'-6" Ll NORTH CMaM= A 01 MAWMEW Commum DIV" 3'-0" 4- aloft 415 j I J1 1 111 A lift"E SrV 7 9S7-2 0 3 . 4 'to). 10 -C)l PY T*rF. HANDICAFFED SIGN NOT TO SCALE MASTER FLAN GREENFIELD 5HOFFING CENTER TWP. NO. 8, CRAVEN COUNTY, NORTH CAROLINA FOR: 54[LE*r 4 4560CIATES/ INC. 405 WESTERN BLVD. JACKSONVILLE, NC 28540 DATE: 09-28-95 GRAPHIC SCALE: 1"=30' 0 10 20 30 60 90 SCALE: 1 " =3 0' Parker & Associates, Inc. 1mg Horizo Consulting Engineers - Land Surveyors - Land Planners P.O. Box 976 - Jadmonville, North Carolina - 28541-0976 Phone (910) 455-2414 - Fax (910) 455-3441 '1 'r15'+ i;._ LU - - - :.1: ,:.. ?..� : s •'it, _i L h -Li.ij'? 'L r 2- DRAINAGE DATA CHART AREA 010 DIAMETER GRADE LENGTH 010 OUTLET LEGEND PIPE (ACRES) (CFS) (INCHES) (FT/FT) (LF) VELOCITY NOTES: R.C.P. - REINFORCED CONCRETE PIPE A 1.0 7.17 24 0.002 184 N/A CB#1 to C8#2 L.F. - LINEAR FEET SY - SQUARE YARDS B 1.7 11.0 24 0,0025 24 4.1 Scour Pod at Outlet PERMANENT POOL pp �. Y - CUBIC YARDS C 1.8 11.6 24 0.004 130 5.1 Scour Pod of Outlet PERELEV. 25.2 CL - CENTERLINE C&G - CURB & GUTTER 0-CIA - SCOUR PAD 110-7.17 In :k '\ $g - RIP RAP All Pipes Reinforced Concrete. ` xF2-8--.-Q PROPOSED SPOT ELEVATION x x - SILT FENCE Q TOP OF POND - SEDIMENT TRAP ELEV. 28.0 / �--- - FLOW ARROW CONTOUR TEMPORARY POOL / ELEV. 26.7 O / �C ONCRXT'E PADS M.H. - MANHOLE 66a0 / �4 TO BE REMOVED \ j - HANDICAP PARKING SPACE C.B. - CATCH BASIN A POWER LINE / STORMWATER � B4O- -BLOW-OFF / DETENTION W.S. -WATER SERVICE - o F. 4"'CMFI POND ' S.S. - SANITARY SEWER / `4 �x F.H. -FIRE HYDRANT 3.1 SWALE / 182.00' ASPHAL FLUME 00 /� a)G. V. - GATE VALVE ° 1 - 19 a OQ �g ' NN ■ W.M. - WATER METER SCOUR PA N �i / I V. i 4- RQP O o C.O. - CLEAN OUT INV. OUT / Q 4" CdcG 25.4 �� / -- V - --1- -r_ CONCRETE I- _- �7 - T -" F 7 T �-T Iq / I i � � ,•.!.--` � I I i I I . 1 � C.B. #2 � 22 spaces - - - B GIN / 2 15 spaces SCOU TOP 28.2 130 L.F. 24 RCP 00.4% /_ - PAD r 1 V. 0 (L iNV. 25.1 C&G 25.0 13 spaces BEGIN - - - f C&G --- INV. / �x aEA 15'X30' INVERTED CROWNNT �� DUMPSTER IN ASPHALTn PAD 9 spaces $H OP S 4" CONCRETE 4, WALK u F.F. ELEV. -� 184 L.F. 16 spaces I IRAMP_ x m a ± `e 24" RCP 00.2% "All - - - 10 S.Y. 6 IA. d TRANSFORMER PAD 15 spaces Q I / RIP RAP- / ASPHAL UME I 4 d a a 15 spaces .d C.B. #1 2 FOOD LION 'f 3 =2 13' is spaces T INV.6 8 7.9 25.4 TRACT #3 F.F. ELEV. 7 1 DEVELOPMENT) 32.I d d I a J rA Lo 1 9• 15 spaces ao ,�, I 4, TYP. cn o 4 2S.9 N x _ OD ao v OD Z INVERTED CROWN 15 s aces 0, p IN ASPHALT �` ^� m a x RAMP ASPHAL UME I ® " 10 S.Y. SHOPS IA. IRIP RAP ® 7 spaces F.F. ELEV, v �15 spaces EXISTING SIGN ® e® 32.7 l l TO BE REMOVED dw -- SWALE ® ® r= ® � 24" C&G 14 spaces12951 j x ® M - - 2V. OUT - OHO - - - - IN INVERT ED PAVE CROWN ® �� 0O0O0O i 56 EIF. O 0 O S 05'51'16" W COPAQ 0 Q 0 Q 0 Sr 1'29'39" W 5 79 --- ---- ------------- _ 11 - A 0� O O 30. R 25.81N SILT FENCE NV• OUT R O gyp• INV. IN INV. IN [SCOUR PAD 3 2fi.1 34 O O O R 26.3 SILT FENCE 26.3 60 L.F. 15" RCP IREMOVE EXISTING 15 PIPE Ck - fk -- 56 L.F. 15" RCP ®0.3i6 MATCH EXISTING STABILIZED MATCH EXISTING STABILIZED MATCH EXISTING PAVEMENT CONSTRUCTi PAVEMENT CONSTRUCT! PAVEMENT ELEVATION rs28.4 ENTRANCE ELEVATION fs28.7 ENTRANCE ELEVATION $328.0 \ R/W GREENFIEL.D 5OULrEVARD N.C•5.R. 1-146 cool R/W R1l' REV.-CAS-10/06/95-CHG. SPOT ELEV., C&G; ADD INVERTED CROWN }1 5 5 i i § T *i, *'�` ^^---r - >-� r• i , i 1 '� J ,C �i:$ �.� ' � i oi' h .F i r,l, r .i r. i.a.: il.��. .. a •,1 .. 1,.., .r, ., .. tl..n �a.i.1f r!.(r.. .flf. it -L t. ' ,. 1'r [ , 1 , !. , / fr.t'illil1'H v,tr f.!-J!��•.'/4lr• V 1 r,t?.t• ' f r ♦ %! r r. 1 r �.' i�r 1'ii GENERAL NOTES: 1. The Stormwater pond shall be permanently vegetated and operational prior to construction of any impervious surface. 2. Swale construction along Northern property boundary extending off -site through the property of Gene A. Jackson to the highway ditch shall be coordinated with the owner and Mr. Jackson. 3. All storm drainage piping shall be reinforced concrete pipe except pipe connecting forebay and pond and pipe exiting pond which can be corrugated aluminum or metal pipe. 4. Subgrade preparation shall be done in accordance with recommendation of Soils Engineer, Geotechnologies, Inc., in report dated May 12, 1995. Contact owner for copies of this report. 5. Boundary and topographic survey data prepared for Bailey and Associates by James C. Simmons and Associates, Registered Land Surveyors. 6, Upon recommendation of Soils Engineer, Geotechnologies, Inc., parking lot section shall consist of 2-inches type 1-2 asphalt, 6-inches coarse aggregate type base course, over compacted subgrade. Heavy paving section for primary drives and rear of center shell consist of 2-inches type 1-2 asphalt, 8-inches coarse aggregate type base course, over compacted subgrade. 7. Concrete for curb and gutter shall be 3000 psi. 8. See Master Plan for staking and other information. GENE A. JACKSON PROVE RT* ' EEPEN EXISTING SWALE AINTAIN :1 SIDE SLOPESI GENE A. JACKSON PROPERTY EXISTING-- ^-/�p`�C INV. IN 24,77 AZISIRIVTI: . r r -�p•Y"+lit 1111j1\,1�1 SHEET 2 OF E-) FIELD BOOK: DISK NAME: ACAD 256 FILENAME: GFSC_GEN.DWG JOB NO.: C950404-G1747 CAS ,�, I,1� GREENFIELD BLVD no Jo HE�'O c0 SiTE '� FERN GREENFIELD BLVD VICINiT`I' SKETCH NOT TO SCALE EROSION CONTROL PLAN NOTES: 1. Construction Sequence: a. Notify North Carolina Department of Environment, Health and Natural Resources office in Washington, North Carolina for notification of pre -construction conference prior to beginning construction. b. Install stabilized construction entrances at Greenfield Boulevard. Northernmost driveway entrance shall not be used for construction access to site. C. Install silt fence paralleling roadside ditch along Greenfield Boulevard as indicated on plan. d. Excavate area for stormwater pond. Contractor should over excavate by 1 foot to elevation 19.2 to allow for sedimentation during construction. During site grading operations all site drainage shall be diverted to pond area until permanent drainage features are installed. Suitable materials from pond excavation shall be used for building pod in accordance with recommendation from Soils Engineer, Geotechnologies, Inc. e. Rough grade project site and install storm drainage piping and catch basins. Catch basins shall be constructed with sediment barrier in accordance with plan detail. f. Install swale at rear of building along with sediment trap at entrance to Pipe "C"• g. Install water and sewer utilities. h. Install stone base course. i. Fine grade stone base course and place asphalt surface course. j. Seed, fertilize, and mulch all disturbed area within 30 days of completing grading work. 2. Seeding Specifications Apply lime and fertilizer and work into seed bed. Seed mixture shall be distributed uniformly and covered with a clean straw mulch. Where slopes exceed 4%, asphalt tack shall be applied. Material and application rates follow: MATERIAL APPLICATION RATE Lime 1000 Ibs/ac. Fertilizer (10-10--10) 800 Ibs/ac. "Rebel" Fescue 100 Ibs/ac. Common Bermuda (Unhulled Sept.1 - April 1) 25 Ibs/ac. Mulch 1.5 Tons/ac, TIE SWALE TO EXISTING ROADSIDE DITCH 024.9, DEEPEN EXISTING ROADSIDE A MAINTAIN NMIN IMUM, DITCH M 2:1 SIDE SLOPES GENERAL GRADING, DRAINAGE, AND EROSION CONTROL PLAN REENFfELD SHOPPING CENTER TWP. NO. 8, CRAVEN COUNTY, NORTH CAROLINA E3,41LE*r $ A550Ci,4TE5, INC. 405 WESTERN BLVD. JACKSONVILLE, NC 28540 DATE: 09-28-95 GRAPHIC SCALE:_-1"-30' 0 10 20 30 60 90 SCALE: 1 "=30' F Parker & Associates, Inc.Us Ror,z� Consulting Engineers - bend Surveyors - Lend Planners P.O. Box 970 - lwckeonv lle, North Carolina - 28541-0978 Phone (910) 455-2414 - Fax (910) 455-3441 LEGEND R.C.P. C� — REINFORCED CONCRETE PIPE L.F. — LINEAR FEET SY — SQUARE YARDS rY — rllRlr YARDS REV.—CAS-10/06/95—ADD GREASE INTERCEPTOR 'Df\).. 1`0 1"� *­ , FIELD BOOK: DiSK NAME: ACAD 256 FILENAME: GFSC.,.._GEN.DWG JOB NO.: C950404-G1747 V 1 CAS � err in 1oR1 viCINITI' SKETCH NOT TO SCALE WATER AND SEWER NOTES: W, 10 E� t4 tj0 1. All water and sewer construction shall be completed in accordance with the standard specifications of the City of Havelock's Public Utilities Department. 2. Contractor shall notify Utilities Engineer 48 hours in advance of beginning construction. Coordinate tie—in to all existing utilities with Utilities Engineer. 3. Location of existing water and sewer mains are approximate only and shall be field verified prior to commencing work. Any discrepancies should immediately be pointed out to the Engineer and Utilities Department. 4. As of January 1, 1986, anyone digging with mechanized equipment in highway right—of—ways, private utility easements, or public spaces will be required by North Carolina law to give notice of the proposed excavation to all existing are utilities at least 2 working days before starting to dig. The utility owner is to locate Its facilities in the area of the proposed excavation. Utility member of ULOCO can be contacted at 1-800-632-4949. 5. 4—inch through 12—inch water mains shall conform to AWWA Specifications C-900-75, Class 150. 6. Water mains shall be buried to a depth of 30 inches, unless otherwise noted. 7. Contractor shall maintain comprehensive (depth and horizontal locations) field "as--builts" for all installations and submit this to the Engineer. JD SEWER PLAN ENFIELD 5H0f=f=ENG CENTEfR TWP. NO. 8, CRAVEN COUNTY, NORTH CAROLINA E3AILE*r 4 A550GI,4TE5, iN(:;. 405 WESTERN BLVD. JACKSONVILLE, NC 28540 09 - 2 8- 9 5 GRAPHIC SCALE:, 1 "=30' 0 10 20 30 60 90 1 "= 30' FEET Parker & Associates, Inc. Consulting Engineers - Land Surveyors - Land Planners P.O. Bo: 976 - Jacksonville, North Carolina - 28541-0976 Phone (910) 455-2414 — Fax (910) 455-21"1 pi09 Horfz, i `T ]; TT. {F171 f� i�T-4i,, g5 1i4,i� i �4. -I--Ti T 4b _-�.7 _.. �. "S �.f jl.l. L�-'��_��i-.i�� -.� M� ..,.�_ _ ,..._ _ ._. ,_ 'r '� � .._l _ ._.. � 1 '��•s�_ i'-�EI.�SiJ �" SLOPE SLOPE LENGTH (FT.) <2% 100 2 TO 5% 75 5 TO 10% 50 10 TO 20% 25 >20% 15 REF: EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, D.N.R.C.D. 1988. MINIMUM 2" x 2" x 48" WOODEN POSTS OR OTHER APPROVED MATERIAL NOTE: BURLAP SHALL NOT BE USED. WELDED WIRE MESH DIRECTION OF RUN OFF FLOW WOODEN POST WELDED WIRE MESH --� BACKFILL EROSION do SILTATION CONTROL FABRIC \ GROUND LINE r 24" MIN. 12" / EXTRA DEPTH REQUIRED FOR NON -STABLE SOILS SECTION VIEW TYPICAL INSTALLATION OF SILT FENCE NOT TO SCALE EXISTING ROAD PLAN VIEW STABILIZED CONSTRUCTION ENTRANCE NOT TO SCALE Construction Specifications 1. Stone size - Use MSHA size No. 2 (2-1/2" to 1") or AASHTQ designation M43, size No. 2 ( 2-1/2" to 1-1/2"). Use crushed stone. 2. Length - As effective, but not less than 50 feet. 3. Thickness - Not less than six (6) inches. 4. Width - Not less than full width of all points of ingress or egress. Minimum of 12'. 5. Washing - When necessary, wheels shall be cleaned to remove sediment prior to entrance onto public right-of- way. When washing is required, it shall be done on an area stabilized with crushed stone which drains Into an approved sediment trap or sediment basin. All sediment shall be prevented from entering any storm drain, ditch, or watercourse through use of sandbags, gravel, boards or other approved methods. 6. Maintenance - The entrance shall be maintained in a condition which will prevent tracking or flowing of sediment onto public rights -of -way. This may require periodic top dressing with additional stone as conditions demand and repair and/or cleanout of any measures used to trap sediment. All sediment, spilled, dropped. washed or tracked onto public rights -of -way must be removed immediately. 1 3 SWALE DET61L NOT TO SCALE COMPACTED SUBSOIL J ASPHALT PAVING DETAIL NOT TO SCALE REV.-CAS-10/05/95-CHG. C&G DETAIL 1 3 TOP OF POND 28.0 36" DIA. TRASH RACK----- ACK ALUMINUM ANTI -VORTEX PLATE TO BE 4-3' ANGLES TO PROVIDED IN TRASH RACKS SUPPORT TRASH RACK TB" ALUMINUM BASE SUPPORT PLATE BOTTOM OF POND ELEV. 20.2 36" CORRUGATED ALUMINUM TRASH RACK WITH ALUMINUM GRATE TOP. GRATE TO HAVE 1" DIAMETER (MAX.) OPENINGS AND TO BE WELDED TO TRASH RACK TOP. 2" ALUMINUM PIPE WELDED TO OUTLET PIPE. INVERT OF CONNECTION TO OUTLET PIPE TO BE AT ELEV. 25.2 ANTI -SEEP PLATE 18" CORRUGATED ALUMINUM OUTLET PIPE 18" CORRUGATED ALUMINUM RISER PIPE ALUMINUM ANTI -VORTEX PLATES TO BE PROVIDED IN TRASH RACKS STORMWATER DETENTION POND OUTLET STRUCTURE DETAILS NOT TO SCALE OPEN TERRAIN HEAPED BACKFILL, NC UNPAVED AREAS SUBJECT TO TRAFFIC PAVED AREAS CRUSHED STONE OR GRAVEL ROAD SURFACE BACKFILL PAVEMENT BASE MECHANICALLY INITIAL BACKFILL COMPACTED BACKFILL, IN (HEIGHT VARIES MBEDMENT 6" LAYERS 12" WITH HAUNCHING) ,ONE HAUNCHING (HEIGHT VARIES) BEDDING VARIES (HEIGHT VARIES) FOUNDATION (IF REQUIRED, DEPTH VARIES) NOTE: SEE SPECIFICATIONS AND TABLES GEN-1, GEN-2 AND GEN-3 FOR ADDITIONAL DETAIL TYPICAL SEWER PIPE EMBEDMENT AND BACKFILL SECTION NOT To SCALE GROUND ELEV. GROUND ELEV. -�28.0 INV. 25.2 N28.0 00 0 BOTTOM OF FOREBAY 1 23.0 1 �� DRAINAGE SVYALE 3 12' 28 L.F. 27" CMP INV. IN AT FOREBAY, ELEV. 25.2 FOREBAY SECTION B-B NOT TO SCALE R CLOW F-2500, DARLING MARK 73, OR MUELLER CENTURION MODEL A 421 FIRE HYDRANT WITH 1-4 1/2" PUMPER NOZZLE AND 2-2 1/2" HOSE NOZZLES REINFORCED CONCRETE COLLAR 2"I 30" x 30" x 6" ►9 �� 7 DEWEY BROS. VBX-TE-100 �Q M vE6" VALVE BOX OR APPROVED EQUAL GATE VALVE fM.J. LOCKED HYDRANT - TEE OR TEE WI TH APPROVED PIPE j� RESTRAINT CONCRETE THRUST BLOCK PLACED AGAINST UNDISTURBED EARTH M.J. LOCKED HYDRANT ADAPTOR OR APPROVED PIPE MIN. OF 3 CUBIC FEET OF CRUSHED STONE FOR DRAINAGE TYPICAL HYDRANT SETTING (SECTION) NOT TO SCALE DEWtIEY BROS M.H.R.C.R.2001 6 ,/r 1/2' CEMENT MASTER ON EX1EMOR SURFACE AND VERTICLE SIDES OF N7 RM WALLS FOR BRICK OR BLOCK M. H. - - ---� NOTE: INCREASE WALL TO 1r BELOW �o 10 s A _ R _ S _ A _ 4 _ S`_' _ S`_' A`_' A`_' L`_ SECTION C.I. MANHOLE COVER RING MANHOLE STEPS AS SPECIFIED FIN j F10411ion . ,,,1010 • NOTES: 1. M.H. DEPTH IS MEASURED FROM TOP OF C.I. RING TO CENTERLINE INV, OF M.H. 2. M.H. DROPS ARE REQUIRED WHEREVER INV. IN IS 2,5 FEET OR MORE ABOVE INV. OUT. SANITARY SEWER STANDARD MANHOLE NOT TO SCALE TOP OF I 24" CONC. POND C&G ELEV. 28.0 OUTLET PLAN M" STRUCTURE PAVED 8' 10' DRIVE ASPHALT CURB 1 2, 3 1 2 1 2" I-2 BOTTOM OF POND 2 ELEV. 20.2 PERMANENT POOL TEMPORARY POOL v v v v v v v v v v ELEV. 25.2 ELEV. 26.7 - - - - - 8" CABC BASE SEC'nON A -A STORMWATER POND SECTION A -A ASPHALT ELUME DEI61L SCALE NOT TO NOT TO SCALE GROUT -\ FINISHED GRADE i TEMPORARY SEDIMENT STORAGE SILT 24" X 24" HEAVY DUTY FRAME AND GRATING 24' MAX. PROPOSED SUBGRADE KEY -IN MIN. 12" BARRIER PVE DIAaMERM + lr SILT BARRIER FABRIC TO REMAIN s" CONCRETE PIPE BRICK OR BLOCK_"Z I " 8" #4 REBAR AT 12" O.C. E.W. NOTES: 1. SEDIMENT STORAGE TO BE INCRESED ON AN AS NEEDED BASIS. 2. INCREASE IN SEDIMENT STORAGE SHALL NOT BE PERFORMED BY EXCAVATING ANY DEEPER THAN 24" FROM PROPOSED FINISHED GRADE FOR PLACEMENT OF PAVEMENT. 3. ALL SEDIMENT, WET MUCKY, OR YIELDING SOIL MATERIALS COMPACTED IN PLACE PRIOR TO PLACING BASE COURSE TO FINISH COMPACTED GRADE. 4. SILT BARRIER FABRIC TO BE NON -WOVEN SYNTHETIC FABRIC MEETING N.C.D.O.T. STANDARDS FOR SHOULDER DRAINS, 5. PROVIDE WEEP HOLES AT 24" ON CENTER SPACING, MINIMUM OF 30" DEPTH AT MINIMUM 6" INTERVALS. YARD INLET CATCH BASIN WITH TEMPORARY SEDIMENT TRAP NOT TO SCALE SCH. 40 STEEL 4' PAINT BOLLARD PIPE BOLLARD FILLED SAFETY YELLOW MITH CONCRETE 44 42" 4' PIPE HY1 w R FIRE HYDRANT BOLLARD DETAIL NOT TO SCALE 3000 P.S.I. CONCRETE - 6" 2" 1-2 8" CABC COMPACTED SUBGRADE 4" ABC -TER AND PAVING SEC],ON CA�� NOT TO SCALE ;:�` p��;�•,•• �y •. • 25 "-' DETAIL SHEET 1/2 D RIP RAP �1/ 1) GREENFIELD 5HOFFING CE�C"��fR SECTION VIEWS MEDIAN STONE DIAMETER - 6" 1. D = INSIDE DIAMETER OR WIDTH OF CULVERT 2. MINIMUM STONE THICKNESS TO BE TWO TIMES SPECIFIED STONE DIAMETER. RIP RAP 5�QWR PAD NOT TO 5CAU SHEET 5 OF 5 FIELD BOOK: DISK NAME: ACAD 256A FILENAME: GFSC-DET.DWG CAS JOB NO.: C950404-G1747 _ L IN CHANNEL PLAN VIEWS L 1� 12' 2 4 TWP. NO. 8, CRAVEN COUNTY, NORTH CAROLINA FOR. 5 AiLE)' 4 ,A&SOCIATE5, INC. 405 WESTERN BLVD. JACKSONVILLE, NC 28540 DATE: 09-28---95 SCALE: AS NOTED Parker & Associates, Inc. 4i1ac Horrz, Coneulting Engineers - Land Surveyors - Land Planners P.O. Box 976 - Jac1L'sonvflle, North Carolina - 28541-0976 Phone (910) 455-2414 - Fax (910) 455-3441 T1♦ �_ _ �T-. R -,y- - � !. � f- T _� ., • r. - IT � r �l--•F' -ter iT. -[,-.-. .,-