Loading...
HomeMy WebLinkAboutSW7120701_APPROVED PLANS_20120822STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW ���_0 70Z DOC TYPE El CURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE DOC DATE YYYYMMDD A OWNER: EASTERN PRIDE, INC. 2405-F NASH STREET WILSON, NC GENERAL CONTRACTOR - STOCKS AND TAYLOR CONSTRUCTION, INC WASHINGTON. NC SUMMARY OF SITE: GENERALBUILDINGINFORMATION BUILDING USE: COMMERCIAL — RETAIL BUILDING SIZE: 7995 SF LOT SI ZE 0.913 AC.. ZONING INFORMATION: ZONING: HB SETBACKS:? MINIMUM BUILDING SETBACKS (UNLESS NOTED) FRON T: N /A SIDE: NA REAR: NA FEET UTILITIES: WATER LINE — TOWN OF BELHAVEN WASTEWATER — TOWN OF BELHAVEN ELECTRIC — TOWN OF BELHAVEN WASTEWATER SERVICE: 4"SEWER WATER SERVICE: 3/4" WATER SERVICE: NEED FOR DIFFERENTIAL PRESSURE REDUCING DEVICE ELECTRIC SERVICE-- UNDERGROUND NATURAL GAS -- N/A, ALL NEW SERVICES SHALL MEET ALL NC BUILDING CODE REQUIREMENTS ALL EXISTING UTILITIES ARE SHOWN BASED ON FIELD EVIDENCE AND PREVIOUSt PLANS: PRIOR TO ANY DIGGING NC ONE CALL SHALL BE CALLED AND CONFIRM LOCATION AND SIZE OF ALL EXISTING UTILITIES. PARKING REQUIREMENTS PARKING SPACES TO BE TYPICAL. (9 FEET X; 18 FEET) UNLESS OTHERWISE NOTED PARKING SPACES REQUIRED. N/A PARKING BUILDING CODE REQUIREMENTS: N/A PARKING PROVIDED TOTAL — 30 HANDICAPPED ACCESSIBLY — 2 HANDICAPPED ACCESSIBLE PARKING TO BE (2 EQUAL SPACES) PER LOCAL CODE — THE PROPERTY IS SHOWN ON FLOOD INSURANCE RATE MAP 3720760600J, DATED MAY 15, 2003 AND A PORTION OF THE PROPERTY IS LOCATED UN A SPECIAL FLOOD HAZARD AREA (LOCATED IN SHADED ZONE AE EL 8); r V[CINITY MAP v Toa� COUZYR d re ` 4� " SITE "Al FINAL PLANS FOR REVIEW ONLY NOT FOR CONSTRUCTION _--i �„ .i �---- SS ----- ss 2" SURFACE COURSE 8" ABC STONE COMPACTED SUBGRADE 1 TYPICAL PAVEMENT SECTION Scale: Not Ta Scale: �P.RPH 4t�� 0 . n G)_5jE_P� LINDA K. POUNDS D..B. 1127, PG. 606 TRACT 1 p,C, F,: SLtDE 351-7 DITCH TO BE RELOCATED TO PROPERTY LINE SS —� W --i • EXISTING OPEN TOP IRON PIPE ® EXISTING NCGS HORIZONTAL STATION EXISTING POWER POLE ■ EXISTING 6"1 CONC. MON. © EXISTING NCDOT R/W MON. --um— vW----aA+— OVERHEAD ELECTRICAL LINE EI TELEPHONE PEDESTAL 20 0 2G 40 60 GRAPHIIC SCALE — FEET SAND FILTER DA 1 DITCH I I A"N. .J--. MITER STOP T tv w _j 24- MM. FROM THE - 14 ACN} HOUSE SCRV1Cf: J HOUSE BOTTOM' OF DITCH OTHERS SERVICE TUBaJD L[NOiNIA4 REOV —ry KEEP LINE SLAOK J 'NETER BM TO BE FURNISHED AND P METALLED BY UTILIFr ty CONTRACTOR, SERVICE SADDLES SHALL BE: USED ON ALL WATER LINES a" ANp SMALLER. SERVICE SADDLES SHALL ALSO BE USED ON, 4" AND LA=R PVC WATER MANS WHICH -DO NOT ME[T THE R[OINREMENTS RNCE_$ADDLE OF AWWA C-400, CLASS ISO. i NMVM LONER OVER SERVICE LINE SHALL BE 241 WIETER Bit SHALL. NOT EE INSTALLED IN SLOPE OF !ITCH. ATE* MAIN Z 3/4" - 1" WATER SERVICE DETAIL ScalL-: Not To Scale: 3 RPZ/BFP DETAIL Si Not To Scale: VARES (SEE MANUFAC-RIRER) MUMPLE ASSEMBLY SS 1 OR CLASS 2 E: 1060 94.411AIM 17HERPROOF CONCRETE OR APPROV0 DRAIN PORT - PROWZ POSITIVE DRAKM E OUT OF ENCI.fl6UiE 7K (Z&AZ II �I7 a I I l I,I .1 . /. OR Esi 11%wmwa2r II �: • P. I III. a� � I Ii P' 4" 3PS CON=WLJ 000 ihlmulm E• ANNULAR AREA BLAB. ONUFACr S PER ER OPEN" SP ►1IINS Y FLJDW AO* , NOTES. 1) REDUCED PRESSURE PRINCIPLE BACKFLOW, #?REVELATION ASSEMBLY SHALL COMPLY APPROVED WITH ASSE 1013 & AWWA C511. NORTH CAROUNA EIWIaRO�: -, ~L "NIT 2) DOUBLE CHECK BACKFLOW' PREVENTION VANAGEMENT COMMISS;ON ASSEMBLY SHALL COMPLY WITH ASSE 1015 & AWWA C510, 0-VISION OF WATER QUALITY 3) BACKFLOW PREVENTION ASSEMBLY SHALL Date 2-2— 20 LZ SE INSTALLED WITHIN 5-FT OF THE METER BOX, BACKFLOW PREVENTION ASSEMBLY SHALL 5#ormwater Permit No.. Sir t Z 0-7-PI SE CENTERED ON CONCRETE OR APPROVED FIBERGLASS MOUNTING PAD AND CENTERED WITHIN ENCLOSURE, 5) MINIMUM INSULATED CLASS I OR CLASS II, ASSE 1060 WEATHERPROOF ENCLOSURE (REQUIRED (HEATING OPTIONAL 6) OPTIONAL 120V GFCI ELECTRICAL G`j`\M/ (RECEPTACLE TO BE INSTALLED IN RECEIVED � ACCORDANCE WITH THE NC ELECTRICAL CODE FOR OUTDOOR OPERATION, 7) PIPE MATERIAL SHALL BE PVC ��;� - � Lu'IL (SCH. 80 OR BETTER), COPPER (TYPE K) OR BRASS (ASTM B43). $) INSTALLATION SHALL BE IN i A / e R O COMPLIANCE WITH ALL APPLICABLE TOWN DWQ �� �jl�i � ORDINANCES AND SPECIFICATIONS IN ADDITION TO THE NC PLUMBING CODE. 9) PROPERTY OWNER SHALL BE RESPONSIBLE FOR MAINTENANCE AND OPERATION OF BACKFLOW ASSEMBLY, AND COMPLIANCE WITH REPORTING AND TESTING REQUIREMENTS. I IL CL •v Z_ = c a a v W -a al z 4 J 0. H J N W I- ra 4, pole mz .w SEAL 20212 s z= M �i �PHtsE 2 "AN UCO ENGINEERI SERVICES, fPLLC LICENSE NO. P-0530 pjwM- 4a) . 4 I E g necrinz I V4CS PAMLICO ENGINEERING SERVICES 128 Abbey Lane Washington, NG 27889` 252-945-2983 pespllc@embarqmall.com R�Fes. - 12017 Scale: lit_ 20' Sheet No. C-001 fY)a,� a svir »a��o � OWNER: EASTERN PRIDE, INC. 2405-F NASH STREET WILSON, NC GENERAL CONTRACTOR -- STOCKS AND TAYLOR CONSTRUCTION, INC WASHINGTON, NC SAND FILTER DIM. NOTE; AVG DIMENSIONS SHOWN FOR EL. 6.5 AND 5.0' ACTUAL AREAS FOR DESIGN WERE TAKEN FROM ACAD GENERATED CONTOURS AS +AF = TOTAL SURFACE AREA 378 + 428.5 = 806 SF 70*21 /2 = 735 SF �. 1 c 70.3 SAND FILTER 1 AS +AF = TOTAL SURFACE AREA 383 + 399 = 782 SF 66*24/2 = 792 SF 66.0 I SAND FI LTE R 2 PR POSED QV RFLOW STRUCTURE SEI, DETAIL, RIM = 6.5 w /WEIR EL. 6.4 Q // FOR EARTHEN l Al I RF H0140GENEOUS AND CLASS CL 1, CL--2 OR CH 2:1 SI E SLOPE (TYP) I I F STABILE E DITCH BANK�� WITH M TTING EIE SANb FILTER MEDIA TO M ET ASTM C 33 T EL. 6.5 N R 3:1 SI SLOPE A/ 8" ROOF INV 6.74 INV OUT AND FILTER 2 DA 2 VOL 575 CF STRUCTURE SEE DETAIL RIM = 6.5 5" RCP OUTLET PIPE W/ FE AND ANTI SEEP COLLAR OUTLET PROTECTION WITH CLASS B RIP RAP WITH FILTER FABRIC =5' INV IN = 3.0 CMVa ��0H SEQUENCE 1. OBTAIN AND POST COPY OF CERTIFICATE OF EPOS40N CONTROL PLAN APPROVAL. 2, CLEAR SITE ONLY AS NECESSARY TO INSTALL EROSION CONTROL DEVICES AS INDICATED ON THE DRAWINGS OR SPECIFIED IN THE SPECIFICATIONS, 3. ONCE EROSION CONTROL DEVICES ARE INSTALLED, BEGIN CONSTRUCTION OPERATIONS. 4, MAINTAIN EROSION CONTROL DEVICES AS NECESSARY DURING CONSTRUCTION, INSPECT DEVICE AFTER EVERY RAINFALL EVENT AND CLEAN OUT TRAPS AND /OR CHECK DAMS WHEN HALF FULL, z EX. DITCH TO BE RELOCATED 5. AS CONSTRUCTION PROGRESSES, INSTALL ADDITIONAL EROSION CONTROL DEVICES AS INDICATED ON THE DRAWINGS, CALLED FOR IN THE a, �. a Q INSIDE PROPERTY LINE AS SHOWN SPECIFICATIONS. OR AS NEEDED OR OIRECTED BY ENGINEER, Z B. SEED AND MULCH DISTURBED AREAS AS STATED BELOW BASED ON WORKING DAYS; FILL EXISTING DITCH WITH A. UPON COMPLETION OF ANY PHASE OF CONSTRUCTION IL SUITABLE FILL MATERIAL B. WEN WORK WILL NOT PROCEED IN AN AREA WITHIN THE ABOVE TIME MAME. 7 AFTER SITE IS STABILIZED REQUEST AN INSPECTION BY THE ENGNEER UPON APPROVAL OF SITE STABILIZATION REMOVE TEMPORARY Q EROSION DEVICES, DRESS OUT AREA AND SEED AND MUCH, PERMANENT EROSION CONTROL DEVICES SHALL BE INSTALLED AND c a APPROVED BY ENGINEER, c „ CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 4 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF APPLICABLE, RIP THE ENTIRE AREA TO 6 INCHES DEPTH, REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE j---- PROP, SWALE TO DIVERT SITE REASONABLY SMOOTH AND UNIFORM, WATER INTO BMP 1 y APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL, IL CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM, REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. SEED ON FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EOUIPMENT OR CULTIPACK AFTER SEEDING, WEIR TO BE USED AS A FLOW SPLITTER DEVICE MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH, A DURING STORM EVENTS GREATER 7'94 THAN 1 YR 24 EVENTS EVENT THE INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDING WITHIN SWALE WILL OVERFLOW TO AVOID THE PLANTING SEASON, IF POSSIBLE. IF STAND SHOULD BE OVER 50 DAMAGED, ADDITIONAL DRAINAGE INTO THE REESTABLISHED FOLLOWING ORIGINAL LIME, FERTILIZER AND SEEDING RATES. SAND FILTER,USE SOD TO ESTABLISH GROUND COVER AND PREVENT EROSION NOTE' 0 OF THE BANK. CONTRACTOR SHALL PROVIDE A PERMANENT SEED COVER ON ALL AREAS DISTURBED WEIR EL. = K.6.DURING CONSTRUCTION OPERATIONS, INCLUDING ANY DISTURBANCE TO THOSE AREAS THAT WERE SEEDED DURING PREVIOUS WORK, 10 0 z ALL. SPOT ELEVATIONS ARE TOP OF ASPHALT UNLESS OTHERWISE NOTED � 2 TOB CONTOURS ARE SHOWN IN 1' INCREMENTS 0 W THE PROPERTY IS SHOWN ON FLOOD INSURANCE RATE J U 6' MAP 3720760600J, DATED MAY 15, 2003 AND THE PROPERTY IS LOCATED !N A SPECIAL FLOOD k� 2 HAZARD AREA (LOCATED IN SHADED ZONE AE EL 8); (� fJ W sw a m 6.6 =EEC G PLAN 1. TEMPORARY SEEDING un 1 sw PLANING DATES GRAB'S TYPE POUNDS/ACRE. 6.50 DEC. 1 - APR. 15 RYE (GRAIN) 120 1 KOBE LESPEDEZA 50 APR, 15 - AUG. 15 GERMAN MILLET 40 AUG. 15 - DEC, 1 RYE (GRAIN) 120 LIME 3,000 1 SEDIMENT BASIN FERTILZER 10-10-10 800 1 VOLUME 756 CF MULCH STRAIN 4,000 =5' INV OUT =2.5 7.80 -��' VOLUME 798 CF �`` �. TA � i DEPTH = 2 -18,. DEPTH = 2' 7.$O t 2. PERMANENT SEEDING SW [ 1 PLANING DATES GRASS TYPE P_OUt�fACRE 10 =2.55 CFS ,�arjrrurr 10=4.01 FPS 5 TA TA SAND FILTER 1 SEPT. 1 - OCT. 3 TALL FESCUE 200 A =0.38 AC 7 n3i TA DA 1 ROBE LESPEDEZA 50 �.`` Lo / 8-' ROOF DRAIN INV 7.1 AT 0,4% INV OUT 6.6 l \ ,mi Q'a PROP, SWALE TO DIVERT SITE 1 7.44 ` 90 LIME 4,oDo� WATER INTO BMP 2 VOL = 643 CF RYE (GRAIN) 25 TA TA FER nUZER 10-10-10 1,000 = ' EAR. l ` ]] \ MULCH STRAW 4,000 y 1 1 7 38 7.75 1. i 7.15 / 15" RCP OUTLET PIPE W/ FES w� rr�20212 �.; AND ANTI SEEP COLLAR �.,'Qj•.N��N>��• TOP OF BANK , 1 TA �- sw OUTLET PROTECTION '�'•.,C/MPt-1>La``'� PROP. SWALE TO 6, 75 � CLASS B RIP RAP gT�+e1Ua 1,aaa EL 6.95 6 S2 DIVERT SITE WITH FILTER FABRIC e WATER INTO BMP 1 L=5' INV IN = 3.0 7.25 W=5' INV OUT =2.5 Z w� TA w D=18" �T 6.7 6.85 TA 6.90 010 = 2, 81 CFS PAMLICO LEiCENSEERING P-0530ES, PLLC S MA TA V10= 4.14 FPS 6 g5 FTW-j IAI DA =0.53 AC PAVEMENT .-r.�• - ". - • ► ummmillow b'1Oil � m--1 ! �I SHwT EL. 2' BELQ EX• ! - 7 CLEAN TON S DEEP ETWEEN SAND AND�STGNE 3 SAND FILTER 2 NTS EL. 6. 3:1 SIDE SLOPE (TYP) GROUND SHWT EL. 2' BELOW EX. P: EP 6.52 x EP 6. 2 6.55 u 264 CONSTRI ICTION 13 ENTRANCE 100' ROW , V- REGRADE EXISTING DITCH 18" RCP OUTLET PIPE W/ FES ROPOSED OVERFLOW E USED AS TO PROVIDE 2:1 FRONT SLOPE WITH STO PARKING LOT STRUCTURE SEE DETAIL AEFLOW IR TO BPLITTER DEVICE OUTLET L PROTECTION ASS RIP AP RIM = 6.5 DURING STORM EVENTS GREATER WITH FILTER FABRIC x THAN 1 YR 24 HR EVENT THE L=5' INV IN = 0.63 TOB 6.9' SWALE WILL OVERFLOW TO AVOID W=5' INV OUT =0.52 ADDITIONAL DRAINAGE INTO THE D_18" SAND FILTER. USE SOD TO ESTABLISH Q10 = CFS GROUND COVER AND PREVENT EROSION V10= FPS II OF THE BANK. DA = 3 AC + /- 1 SAND FILTER I 1" m20 H 1" -2' V 2:1 SIDE SLOPE (TYP) WEIR EL. 6,75 STABILIZE DITCH BANK USING SOD ALONG 6.9 a TOB 7.0 AREA OF THE SAND FILTER TEMPORARY CHECK DAM e - WEIR OVER SAND FILTER MEDIA INV 6.52 FLOW EL 6.7 -- SILT FENCE TO MEET ASTM C 33 010 = 6,72 EX, GROUND - ARC CHECK DAM 11 `~ -- - f OUTLET PROTECTION I- - SELECT FILL MATERIAL FOR EARTHEN 1 2:1 SIDE EMBANKMENT SHALL BE t I SLOPE (TYP) WATER SURFACE ELEV. HOMOGENEOUS AND Q\o = 2,07' CLASS CL 1. CL-2 OR CH ow = 7.0 CFS ~ ',I DA =1.27 10 AC + SWALE 2 NTS ICTURE SEE DETAIL = 6.5 SITE DRAINAGE DATA TOTAL. IMPERVIOUS AREA 0,5700 TOTAL DRAINAGE AREA 0.9130 SAND FILTER SCHEDULE AREA NUMBER 1 2 DISTURBED AREA AC 0,53 0.38 IMPERVIOUS AREA 0.27 0.3 TOTAL DRAINAGE AREA 0.53 0.38 WATER QUALITY VOLUME ADJ 1125 1200 VOLUME PROVIDED 1399 1373 PAMLICO ENGINEERING SERVICES 128 Abbey Lane Washington, NC 278891 252-945 2983 pespllc@embargmail.com ......... 12017 Scale: in ; 20' Sheet No. CIre 002 - � _ ' � i �--r-r �s^ter-�--•- - ' r • � :` � , ,. • I : � r . 'S ' .` j ' . - - 3 &A Ekl 7W 701 F3 s LINE WEIR WITH RIP -RAP CLASS B OR SOD ACROSS THE TOP TO THE BOTTOM OF THE SLOPE FILTER FABRIC TO �� ��xx TOP OF BERM EL SEE PLANS BE KEYED INTO TOP OF SLOPE AND USED IN AREAS WHERE A PERMANENT STAND OF GRASS HITCH AND BURY FILTER FABRIC EDGE IS NOT ACQUIRED. FILTER FABRIC WEIR LENGTH -10' EL SEE PLANS (MIN' 12" OF FABRIC) 6MINIMUM 12-1/2 GAUGE ` 2' MIN. INTERMEDIATE WIRES MIN. OVERFLOW WEIR DETAIL MINIMUM '°GAUGE 1 LINE WIRES a"cale: Not To Scale: 8'-0" MAXIMUM STEEL POST Y TRASH RACK W/ #6 BARS @ 6" O/C BOTH DIRECTIONS STEPS ALONG A VERTICAL WALL OVER THE EFFLUENT PIPE AND VERTICALLY ALIGNED BASE UNIT ti PERFORATED- PIPE FROM SAND FILTER 6" CARRY RIP RAP UP BANK fM'� v VO U� 1 FREEBOARd VARIABLE A5 DIRECTED B THE ENGINEER WOVEN WIRE FABRIC �i�� D L (MIN.) FT SILT FENCE FABRIC 41 N0. 5 WASHED STit�l£4�W---�` �.r`..�., ". eROO �SILT FENCE FABR 3'-0" 4 FILL SLOPE '°:•a k-9i &91�r 1 dEPTH OF INSTALLED TO ECOND Xwx 26*41.131TCH n ` )- GRADEII_ u RNST COVER NATURAL GRADE OVEKIRINE ICLASS 8 RIP RAP 2-0 WITH FILTER FABRIC ANCHOR SKIRT AS DIRECTED 1 &` MIN. VARIES - BY ENGINEER • Ef30NT ZEW SIDE VIEW �s N T Check Dam Detail USE SILT FENCE ONLY WHEN DRAINAGE AREA DOES NOT EXCEED 1/4 ACRE AND NEVER IN Scale. Not To Scale: SILT FENCE AREAS OF CONCENTRATED FLOW, Scale: Nat To Scale: �--- MAY BE PRECAST OR 8" BLOCK STRUCTURE ��-- ALL LIFT HOLES WHICH COMPLETELY PENETRATE THE MANHOLE SHALL BE FILLED WITH NON -SHRINKING GROUT ALL EXTERNAL JOINTS SHALL BE SEALED WITH AN APPROVED JOINT SEALING MATERIAL 5« 12" BEDDING (#57 STONE) 6 STANDARD OUTLET STRUCTURE Scale; Not To Scale: now now 3' r • L • FLUSH TYPE CLEANWT CAP TO BE INSTALLi CLEANOUT to BE SET - V-S ABOVE FIN. GRADE s n5 gz USE DIP ` COMBINATION WYE AND 1/8 SEND �tY< �a `�,N EX, 3" PVC 22-1/2P"REND ° WELDSOLCAP ' . - STUB OUT T' PAST WYE SCH 80 PVC " SCN. 40 PVC DWV SEWER •'� n ADAPTOR COURNG .'p SERVICE PIPE AT 1% MIN, GRADE.(ASTN 0-2665, 0-17951 P .. p •27-1/2" $EE CWRT MAIN TYPE CONNECTION COMMENTS ASS TRUSS TAPPING IN ACCORDANCE WITH THE MANUFACTURERS SADDLE RECOMMENDATIONS. MNNUM 4" OF JI557 STORE REWIRED UNDER ALL PIP04G, PVC TRUSS GASKETE0 IRI ACCORDANCE V41W THE MANUFACTURERS WYE CpNMENDATIONS. MUMMUM 4" OF #57 STORE REOUIPED UNDER ALL NPING, PVC SOR 3� CASKETED N ACCORDANCE WITH THE MANUFACTURERS WYEC NDATION$. MIMMUM 4' CF 157 STONE REGURED UNDER ALL PIPIRIG. PVC SANITARY SEWER SERVICE DETAIL FOR AREA 1MTH CVR$ AND CUTTER FOR MAINS WITH A MAXIMUM DEPTH OF 12' UNDER'STONE IC SE PIPEINSTALLEDSTANDARD SEWER SERVICE SE DER Rv10E PE 9 Stale: Nat Ta Scale: —STOP POST PER. PLAN J- I O O 7'_61, Q 1 � FENCE TO MEET TOWN STANDARDS 0 I1 04 , DOUBLE GATE W/ WHEEL SUPPORTS W/ WWF —6" REINFORCED �D CONCRETE PAD - 3000 P,S,I, A,A ,° P • 4 D A ASPHALT PAVEMENT PI AN NOTE: 6X6/6-6 STEEL MESH . i� ( #6 BAR 1 ORIFICE OPENING IS • 2 2" 8„ SECTION A --A DUMPSTER PAD DETAIL 73 Scale: Not To Scale: PLAN VIEW STOP POST AND FRONT BOLLARDS SHALL 6" STEEL PIPE, CONCRETE FILLED, THE EXPOSED LENGTH SHALL BE 4' ABOVE GROUND WITH A BURY J�DEPTH OF 3'. POSTS SHALL BE "oVERTICALLY LEVEL. IN AN 18 DIAMETER HOLE BACK FILLED WITH 300 1 PSI CONCRETE. CLASS "I' RIP - PERMANENT SEEDING ON ALL SLOPES 4 TYP. SLOPE DETAIL Scale: Not To Scale: INSTALLATION OF NETTING AND MATTING PRODUCTS DESIGNED TO CONTROL EROSION SHOULD BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, ANY MAT OR BLANKETTYPE PRODUCT USED AS PROTECTIVE MULCH SHOULD PROVIDE COVER OF AT LEAST 30% OF THE SURFACE WHERE IT IS APPLIED, INSTALLATION IS ILLUSTRATED BELOW, 1. APPLY LIME, FERTILIZER AND SEED BEFORE LAYING THE NET OR MAT, IF OPEN WEAVENETTING IS USED, LIME MAY BE INCORPORATED BEFORE INSTALLING THE NET AND FERTILIZER AND SEED SPRAYED ON AFTERWARD, 2. START LAYING THE NET FROM THE TOP OF THE CHANNEL OR SLOPE AND UNROLL IT DOWN THE GRADE. ALLOW NETTING TO LAY LOOSELY ON THE SOIL BUT WITHOUT WRINKLES --DO NOT STRETCH, 3. TO SECURE THE NET, BURY THE UPSLOPE END IN A SLOT OR TRENCH NO LESS THAN 6 INCHES DEEP, COVER WITH SOIL, AND TAMP FIRMLY. STAPLE THE NET EVERY 12 INCHES ACROSS THE TOP END AND EVERY 3 FT AROUND THE EDGES AND BOTTOM. WHERE 2 STRIPS OF NET ARE LAID SIDE BY SIDE, THE ADJACENT EDGES SHOULD BE OVERLAPPED 3 INCHES AND STAPLED TOGETHER, EACH STRIP OF NETTING SHOULD ALSO BE STAPLED DOWN THE CENTER, EVERY 3 FT, DO NOT STRETCH E�iil THE NET WHEN APPLYING STAPLES, 4, TO JOIN TWO STRIPS, CUT A TRENCH TO ANCHOR THE END OF THE NEW NET. OVERLAP THE END OF THE PREVIOUS ROLL 13 INCHES, AND SAMPLE EVERY 12 INCHES JUST BELOW THE ANCHOR SLOT, MAINTENANCE INSPECT ALL MULCHES PERIODICALLY, AND AFTER RAINSTORMS TO CHECK FOR RILL EROSION, DISLOCATION, OR FAILURE. WHERE EROSION IS OBSERVED, APPLY ADDITIONAL MULCH. IF WASHOUT OCCURS, REPAIR THE SLOPE GRADE, RESEED, AND REINSTALL MULCH. CONTINUE INSPECTIONS UNTIL VEGETATION IS FIRMLY ESTABLISHED. r - ---------- -- 15' RCP I 18" I 1 r I I r I I 1 --1—CLASS CLASS B CONCRETE 1 I 1 I I I f I TRENCH« WIDTH L SECTION CONCRETE CIFICATIONS 35 MIN. 15' MIN. NEW CONSTRUCTION EXISTING ROADWAY PLAN 12" MIN, 11 ANTI -SEEP COLLAR 6« MIN, 25' OR WIDTH OF Scale: Not To ScaIQ: PROPOSED STREET, WHICHEVER IS ' GREATER. FABRIC UNDER STONE NOTES: 1. PUT SILT FENCE OR TREE PROTECTION FENCE UP TO ENSURE CROSS SECTION CONSTRUCTION ENTRANCE 15 USED, STANDARD CONSTRUCTION ENTRANCE 2 IF c ON THE SITES ARE SUCH THAT THE MUD 10 IS NOTOT REMOVED BY THE VEHICLE TRAVELING OVER THE STONE, THEN THE TIRES OF THE VEHICLES MUST BE WASHED Scale: Not To Scale: BEFORE ENTERING THE PUBLIC ROAD. PIPE OUTLET TO FLAT AREA NO WELL DEFINED CHANNEL PLAN PLAN VIEW AREA TO BE DISTURBED 1' 2' MOON ARC FILTER 0. 5 WASHED STONE R NO. 57 STONE ROADWAY SHOULDER CULVERT NTS W Lu Z IJ a W 0 IN CHANNELS, ROLL OUT STRIPS OF NETTING PARALLEL TO THE DIRECTION OF FLOW AND OVER THE PROCTECTIVE MULCH, I 18' ANCHOR NETTING IN A OVERLAP PROFESSIONAL SEAL 6-INCH TRENCH, JOIN STRIPS BY ANCHORING AND OVERLAPPING. N.%.t\Wqz ���{{1```'�.� �Q4o. Ess�N SEAL TEMP. DITCH LINER = _., 20212 S Scale; Not To Stale: • �FNG F.' ., ! � ,. tv, PIPE OUTLET TO WELL- DEFINED CHANNEL RIPRAP MIN CLASS DEPTH (d) PLAN A 8 1' - 6" La 1 2' - 2" 1-0 2 3' -0" La o , SECTION THRU PIPE SECTION THRU PIPE NOTES: 1, Lo IS THE LENGTH OF THE RIP -RAP APRON. 2. do IS THE NOMINAL SIZE OF THE OUTLET PIPE, ,3, IN A WELL-DEFINED CHANNEL EXTEND THE APRON UP THE CHANNEL BANKS TO AN ELEVATION OF 6" ABOVE THE MAXIMUM TAILWATER DEPTH OR TO THE TOP OF THE BANK, WHICHEVER IS LESS. WIDEN CHANNEL A5 NECESSARY TO ACHIEVE REQUIRED WIDTH AT DISTANCE Lv FROM OUTLET, RIPRAP ENTIRE DISTURBED PORTION OF THE CHANNEL. 4, A FILTER BLANKET OR FILTER FABRIC SHOULD BE INSTALLED BETWEEN THE RIP -RAP AND SOIL FOUNDATION, Z OUTLET PROTECTION DETAIL Stale: Not To Scale: HLO •�. PAMLICO ENGINEERING SERVICES, PI LICENSE NO, P-0530 m1.0 a2 PAMLICO ENGINEERING SERVICE 128 Abbey Lane Washington, NC 27889 252-945-2983 pespllc@embargmail.com 12017 NTS sheet No. C Inn 0 0 ti f