Loading...
HomeMy WebLinkAboutNCS000330_MONITORING INFO_20191217i STORMWATER DIVISION CODING SHEET NCS PERMITS ' PERMIT NO. C oo DOC TYPE ❑ FINAL PERMIT MONITORING REPORTS ❑ APPLICATION ❑ COMPLIANCE ❑ OTHER , DOC DATE ❑ a�� 1 YYYYM MDD I I December 9, 2019 Attn: Central Files DEC � 7 ZQ�9 N.C. Division of Water Quality 1617 Mail Service Center :,FN-I-IRAL FILES Raleigh, NC 27699-1 b 17 "WR SECTION Central Files: �sATI P.O. Box 5030 2020 Ashcrali AWOUC Monroe. NC 281 t 1-5030 Phone: (704) 289-45 11 Fax: (704) 290-5 194 Finail:'I'yler.Nlcrcer@AT'Imei its.coni Attached, please find stormwater monitoring data for Permit No NCS000330. The originals and one copy are included. The monitoring data is for the following monitoring schedule: Monitorin Period Sample Number Start End Year 1-Period 2 l Jul 1 ", 2019 1 December 3 l" , 2019 Stormwater sampling for Outfall # 02(M) has been determined to be the representative outfah through prior correspondence. "! certify, under penalty of law, that this document and rill attachments were prepared raider- my direction orsupervision in accordance with a system designed to assure that qualified personnel proper-lyguther and evaluate the information submitted. Based ort my inquiry of the person or persons who manage the system, or those persons directly responsible forgathering the info rnmtion, the information submitted is, to the (lest of my knowledge and belief, true, accurate, and complete. 1 am aware that there are significant 17ena1ties for submitting false information, including the possibility of fines and irnprisonrnent for knowing violations." If you have any questions or need additional information, please contact me at 704-289-45 11. Thank you. sincerely, r Tyler Mercer EHS Manager aceAnafytical WWW.y8e1l363.t6m November 21, 2019 Tyler Mercer ATI Specialty Materials 2020 Ashcraft Avenue Monroe, NC 28110 RE: Project: SW02 Stormwater Pace Project No.: 92453311 Dear Tyler Mercer: Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Hunte•sville, NC 28078 (704)875-9092 Enclosed are the analytical results for sample(s) received by the laboratory on November 12, 2019. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNIINELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Matthew Brainard matthew.brainard@pacelabs.com (704)875-9092 Project Manager Enclosures cc: Danielle Barrack, Allvac Mr. Tommy Long, Allvac Mike McManus, ATI Specialty Metals Scott Ryan, Allvac REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 14 aceAnalytical rrriw.pacslabs.com Project: SW02 Stormwater Pace Project No.: 92453311 Pace Analytical Services, LLC 9800 KinceyAve, Suite 100 Huntersville, NC 28078 (704)875-9092 Pace Analytical Services Charlotte 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 Massachusetts Certification #: M-NCO30 North Carolina Drinking Water Certification #: 37712 CERTIFICATIONS South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 VirginiaNELAP Certification #: 460221 North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 VirginiaNELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 14 aceAnalytical ww.pacelshs.= SAMPLE ANALYTE COUNT Project: SW02 Stormwater Pace Project No.: 92453311 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 2BO78 (704)875-9092 Lab ID Sample I❑ Method Analysts Analytes Reported Laboratory 92453311001 Monroe SW02 EPA 1664B AAC1 1 PASI-C EPA 200.7 Rev 4.4 1994 SH1 5 PASI-A SM 2540D-2011 MJP 1 PASI-A SM 5210B-2011 SMK 1 PASI-A SM 5220D-2011 GC 1 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full. without the written consent of Pace Analytical Services, LLC. Page 3 of 14 f Pace Analytical Services, LLC laneMalytical' 4800 Kincey Ave. Suite 100 Huntersvilte, NC 28078078 WWW' p1tel1b2=M (704)875-9 092 ANALYTICAL RESULTS Project: SW02 Stormwater Pace Project No.: 92453311 Sample: Monroe SW02 Lab ID: 92453311001 Collected: 11/12119 08:07 Received: 11/12/19 10:09 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 1664 SGT-HEM, TPH Analytical Method: EPA 1664B Total Petroleum Hydrocarbons ND mg1L 4.8 1 11/21/19 10:39 200.7 MET ICP Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Cadmium ND ug1L 1.0 1 1111511916:23 11/16/1914:32 7440-43-9 Chromium 40.6 ug/L 5.0 1 11/15/1916:23 11/16/1914:32 7440-47-3 Lead ND ug/L 5.0 1 1111511916:23 11/16/1914:32 7439-92-1 Nickel 190 ug/L 5.0 1 11/15/1916:23 11/16/1914:32 7440-02-0 Zinc 339 ug1L 10.0 1 11115/1916:23 11/16/1914:32 7440-66-6 2540D Total Suspended Solids Analytical Method: SM 2540D-2011 Total Suspended Solids 31.3 mg1L 4.2 1 11/14/19 11:47 5210B BOD, 5 day Analyticali Method: SM 521 OB-2011 BOD, 5 day 6.8 mg/L 2.0 1 11/13/19 18:58 11/18/19 13:52 5220D COD Analytical Method: SM 5220D-2011 Preparation Method: SM 5220D-2011 Chemical Oxygen Demand 58.5 mg1L 25.0 1 11/13119 16:41 11/13/19 22:29 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11121 /2019 04:30 PM without the written consent of Pace Analytical Services, LLC. Page 4 of 14 aceAnalytical. ww,pscdaWcam QUALITY CONTROL DATA Project: SW02 Stormwater Pace Project No.: 92453311 QC Batch: 510890 Analysis Method: EPA 1664B QC Batch Method: EPA 1664E Analysis Description: 1664 SGT-HEM, TPH Associated Lab Samples: 92453311001 METHOD BLANK: 2740657 Associated Lab Samples: 92453311001 Parameter Units Total Petroleum Hydrocarbons mg1L LABORATORY CONTROL SAMPLE. 2740658 Parameter Units Total Petroleum Hydrocarbons mg1L Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 4.8 11121/191D:39 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 19.2 16.9 88 64-132 MATRIX SPIKE SAMPLE: 2740659 35510758001 Spike M5 MS % Rec Parameter Units Result Conc. Result % Rec Limits Qualifiers Total Petroleum Hydrocarbons mg1L 4.81.1 19.2 6.1 27 64-132 M1 Results presented on this page are In the units Indicated by the "Units' column except where an alternate unit is presented to the right of the result, REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11/21/2019 04:30 PM without the written consent of Pace Analytical Services, UC Page 5 of 14 aceAnalytical ttlw.psctddts.clua QUALITY CONTROL DATA Project: SW02 Stormwater Pace Project No.: 92453311 QC Batch: 509808 Analysis Method: EPA 200.7 Rev 4.4 1994 QC Batch Method: EPA200.7 Rev4.4 1994 Analysis Description: 200.7 MET Associated Lab Samples: 92453311001 METHOD BLANK: 2735837 Matrix: Water Associated Lab Samples: 92453311001 Blank Reporting Parameter Units • Result Limit Analyzed Qualifiers Cadmium ug1L ND 1.0 11116/1913:51 Chromium ug/L ND 5.0 1111611913:51 Lead ug1L ND 5.0 11/16/1913:51 Nickel ug/L ND 5.0 11/1611913:51 Zinc ug/L ND 10.0 11/16/1913:51 Pace Analytical Services, LLC 9800 Kircey Ave, Suite 100 Huntersville, NC 28078 (704)875-9092 LABORATORY CONTROL SAMPLE; 2735838 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Cadmium ug/L 500 486 97 85-115 Chromium ug1L 500 478 96 85-115 Lead ug1L 500 486 97 85-115 Nickel ug1L 500 484 97 85-145 Zinc ug1L 500 482 96 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2735839 2735840 MS MSD 92452860002 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Cadmium ug1L ND 500 50D 486 496 97 99 70-130 2 Chromium ug/L 0.0054 500 500 466 478 92 95 70-130 3 mg/L Lead ug/L 0.0077 500 500 468 477 92 94 70-130 2 mg1L Nickel ug/L 0.051 500 500 508 518 91 93 70-130 2 mg1L Zinc ug/L 5.6 500 500 5850 5870 56 59 70-130 0 M1 mg/L MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2735841 2735842 MS MSD 92453333001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Cadmium ug1L ND 500 500 499 500 100 100 70-130 0 Chromium ug1L ND 500 500 478 479 95 96 70-130 0 Lead ug/L ND 500 500 486 491 97 98 70-130 1 Nickel ug1L NO 500 500 484 486 97 97 70-130 1 Zinc ug1L 80.3 500 500 565 566 97 97 70-130 0 Results presented on this page are in the units indicaled by the "Units" column except where an alternate unit Is presented to the right of the result REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /21/2019 04:30 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 14 laneAnalyfical" www.pacHabs,can QUALITY CONTROL DATA Project: SW02 Stormwater Pace Project No.: 92453311 OC Batch: 509528 Analysis Method? SM 254OD-2011 OC Batch Method: SM 2540D-2011 Analysis Description: 2540D Total Suspended Solids Associated Lab Samples: 92453311001 METHOD BLANK: 2734380 Matrix: Water Associated Lab Samples: 92453311001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Suspended Solids mg/L ND 2,5 11/14/19 11A3 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875.9092 LABORATORY CONTROL SAMPLE: 2734301 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Suspended Solids mg1L 250 248 99 90-110 SAMPLE DUPLICATE: 2734382 92453406001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg1L 320 331 3 SAMPLE DUPLICATE: 2734383 92453262001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg1L 118 120 2 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit Is presented to the right Of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11121/2019 04:30 PM without the written consent of Pace Analytical Services. LLC. Page 7 of 14 leAnalytical wrwr.yrrcdrtet�.cotn Project: SW02 Stormwater Pace Project No.: 92453311 QC Batch: 509298 QC Batch Method: SM 5210E-2011 Associated Lab Samples: 92453311001 METHOD BLANK: 2733231 Associated Lab Samples: 92453311001 Parameter Units BOD, 5 day mg/L LABORATORY CONTROL SAMPLE: 2733232 Parameter Units BOD, 5 day mg/L 5 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Analysis Method: SM 5210E-2011 Analysis Description: 52108 BOD, 5 day Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.0 11/18/19 13:41 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 198 222 112 84.6-115 SAMPLE DUPLICATE: 2733233 92453449001 Dup Parameter Units Result Result BOD, 5 day mg1L 218 183 RPD Qualifiers 17 D6 Results presented on this page are In the units Indicated by the "Units" column except where an atternate unit is presented to the right of the result, REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11/2112019 04:30 PM without the written consent of Pace Analyticaf Services, LLC. Page 8 of 14 aceAna1j&a1 wrw.pacalmlis.= QUALITY CONTROL DATA Project: SW02 Stormwater Pace Project No.: 92453311 QC Batch: 509346 Analysis Method: SM 5220D-2011 QC Batch Method: SM 5220D-2011 Analysis Description: 5220D COD Associated Lab Samples: 92453311001 METHOD BLANK: 2733655 Associated Lab Samples: 92453311001 Parameter Units Chemical Oxygen Demand mg1L LABORATORY CONTROL SAMPLE: 2733656 Parameter Units Chemical Oxygen Demand mg/L Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers NO 25.0 11/13/19 22:22 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 750 754 101 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2733657 2733658 MS MSD 92453280001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Chemical Oxygen Demand mgtL 4490 100 100 4360 4270 -122 -215 90-110 2 M1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2733659 2733660 MS MSD 92453409003 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc, Result Result % Rec % Rec Limits RPD Qual Chemical Oxygen Demand mg1L 25.7 100 100 129 126 103 101 90-110 2 Results presented on this page are In the units Indicated by the "Units" column except where an alternate unit is presented to the right of the result, REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /21 /2019 04:30 PM without the written consent of Pace Analytical Services, LLC. Page 9 of 14 lacieAnalyficala www.pscdmbs.com QUALIFIERS Project: SW02 Stormwater Pace Project No.: 92453311 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. NO - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. Pace Analytical Services, LLC 98C0 KlnceyAve. Sulte 100 Huntersville, NC 28078 (704)875-9092 PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chtoroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis ofAcrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration, Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES PAS I -A Pace Analytical Services -Asheville PASI-C Pace Analytical Services - Charlotte ANALYTE QUALIFIERS D6 The precision between the sample and sample duplicate exceeded laboratory control limits. M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11/21/2019 04:30 PM without the written consent of Pace Analytical Services, LLC. Page 10 of 14 aceAnalytical` www,pztdsGs.tmn QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: SW02 Stormwater Pace Project No.: 92453311 Lab ID Sample ID QC Batch Method 92453311001 Monroe SW02 EPA 1664B 92453311001 Monroe SW02 EPA 200.7 Rev 4.4 1994 92453311001 Monroe SW02 SM 254OD•2011 92453311001 Monroe SW02 SM 521OB-2011 92453311001 Monroe SW02 SM 5220D-2011 Date: 11/21/2019 04:30 PM Pace Analytical Services, LLC 9800 Kincey Ave, Suite 100 Huntersville, NC 28078 (704)875-9092 Analytical QC Batch Analytical Method Batch 510890 509808 EPA 200.7 Rev 4.4 1994 509861 509528 509298 SM 521OB-2011 509346 SM 5220D-2011 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LI_C, 509381 509390 Page 11 of 14 4L to ZL abed Document Name: Document Revised: February 7, 2018 ace Analytical- Sample Condition U on Recel t(SCUR) Page 1 of 2 Document No.: Issuing Authority: F-CAR-CS-033-Rev.06 Pace Carolinas Quality Office Laboratory receiving samples: Asheville ❑ Eden❑ Greenwood ❑ Huntersvitlef Z Raleigh[] Mechanicsville(] Name: j 9245'331 1A C�c•4..! ��''� Pr®oject1, Wr Courier: ❑Fed�Ex ❑u"P5 ❑USPS dent 11 [) � 1111111 Commercial ❑Pace ❑Other;`/ 1 � 11111 1 UUU ii EEII Y Custody Seal Present? ❑Yes 2]No Sealsintact? []Yes�No Packing Material: ❑Bubble Wrap--fr'19�u ble Bags XNone ❑ Other Thermometer:/„ rypeofice; ❑i et ❑Blue �fA Gurt It): 22T }TQ, 8 Cooler Temp j'C): - 7 Correction Factor; Add/Subtract ('C) 0.0'C Cooler Temp Corrected ('C): USDA Regulated Soll I©N A, water sarrrple) Did samples originatein a quarantine zone within the United States: CA, NY, or SC (Check maps)? nYrs MNn Oato/Initlals Person EMamfnin;Carttents: t-i' - I .�OV-1 I Biological Tissue Yazen? ❑Yes ❑No �N/A ❑None Temp should be above freezing to VC []Samples out of ternp criteria. Samples on ice, cooling process has begun Did samples originate from. foreign source (internationally, Includina Hawaii and Puerto Rica)7 MYes nNn Comments/Discrepancy: Chain of Custody Present7 r es ONO ONJA 1. Samples Arrived within Hold Time? RK ON. N A 2. Short Hold Time Analysis i<72 hr.)? 124 ENO N/A 3. Rush Turn Around Time Requested Yes o ❑N/A Q. Sufficient Volume? es Na N/A 5.. _ Correct Containers Used? �� -Pace Containers Used? cs ,©Yres ONO ONO ❑N/A N A fi. T onta Ciners InlaCt? Yesw ONO N A 7. _ D€ssalved analysis: Samples Field Faltered? ❑Yes No�N/A fl. Sample Labels Match COC? -Includes Date/Time/10/Analysis Matrix: s ONO E,N/A 9. Heads ate in VOA Vials �,5-6mnr 7 Elyes 0Nn / 10. Trip Blank Present? Tri 81ank Custody Seals Present? ❑Yes Yes ❑Na QNQ )2 /A N/A 11. COMMFNTS/SAMPLE DISCREPANCY Lot ID of solit containers; CLIENT NOTIFICATION/RESOLUTION Fleld Data Required? ❑Yes []NO Per;an contacted: Date/Time: _ Project Manager SCURF Review: -„ Date: 4 ( 11. Project Manager SRF Review: _ Date: t'1, }o £6 abed Document Name: Document Revised: February 7, 2018 i aCAnalytrca! Sample Condition Upon ReceE t SCUR Page 1 of 2 Document No,: Issuing Authority: F-CAR-CS-033-Rev.06 Pace Carolinas Quality Office *Check mark top half of box If pH and/or dechlorinatlon Is verified and within the acceptance range for preservation samples, txceptlons� VOA, Collform, TOC, Oil and Grease, DRO/8015 (water) DOC, LLHg "Bottom half of box Is to list number of bottle Project t" W® : 9245331.1 _ mPM: MWB Due st;T 111/21/19 _.__. CLIENT: 92-Allvee NC Z i W Z K v V Y A N v A z C = Y v 2 V a ? vUv 2 _ 6 ? 2 \ g _ C N I = QI � 7 N p LC t I N y7 N r D=Dc C r n Y 0 L z N a Z U a j S a � Q O S OEE T Q d � ? Z U "� ry Q C ?4q C7 0. M 0 « iY' a .Y a a A Z _� a 7 E ' i a '� tc} bi { 0 _ C a a m E m a m a m m a m E a w CEA rr, a. 'rA E a a m E a a m v u -+ l7 4 •� t.7 sc E m t7 4 t7 Q EEC m tS C C9 4 E a �' as T qqE ar c7 } O } �fl t7 } E pE .ri °Wi of eeQf a m GE Q Ji E E Q e� c9 C] L 3 I✓ L A i• S y fi 7 g 9 iD 11 7. pH Adjustment Log for Preserved Samples Sample ID Type of Preservative pH upon recelrt Date preservation adjusted Time preservation adjusted Amount of Preservative added lot It Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carotin DEHNR Certification Office (i,e. Out of hold, incorrect preservative, out of temp, incorrect contalners. PkeAnaVical' rural— -,rr CHAIN -OF -CUSTODY 1 Analytical Request Document The Chain -of -Custody is a LEGAL DOCUMENT, All relevant fields must be compieted accurately. Section A Section B Section C Page: j of Requirod Client Information: Required Project Information: Invoice Infomtalion: f :Dap Report To: Attention 1� 219 2 41 G (. Gopy To: Co ay to , ]REGULATORYAGENCY rQ� d �� ���� NPDES r GROUNDWATER !r DRINKING WATER c r- UST r RCRA OTHER Email o: Purchase Order No.: race Ouoze paermroo: / _ (/ ,Mt/ O _!! Project Name: (, , j r• �(,� 4 � Q, �f Paco Prolaer r�n,uuer: Site Location STATE: - - oquested flue Date/TAT: Project Numw.. Paw Profile It Requested Analysis, Filtered (YIN) Section D Matrix Codes i- x, Raqutred Clexnt fMmtll�eon Marn�x r cony c COLLECTEf3 Preservatives Drinking Water DW r ° Water %%q Wa ste W ater WW U ay COMPOSITE ART CQ dMPOSH o u Z Product P Soillsoud SL N w l{ SAMPLE ID Oil °P ui (A-Z.0.91.-) Air AR m !- o Sample IDs MUST 9E UNIQUE Tissue TS 0 u © ro ,. U ax C Other OT x H ii w a O V LL yr © ZCo fJ c �r{� j} g N SATE rtn!E onre TIME to u ; z x z z O - Ir Pace ProjectNoJ Lab I.D. 3 'iAl I qq .II 7 g I � I SO 11 i t u ADDITIONAL COMMENTS RELINQUISHED BY 1 AFFILIATION DATE TIME ACCEPTED BY i AFFILIATION GATE TIME SAMPLE CONDITIONS - �- a� el CY C��� s. y A Y "- 6+ d x , t 7i -teen V ` SAMPLER NAME AND SIGNATURE ORIGINAL PRINT Namo of SAMPLER: ff O J4ri1Gb r�Id _ fr�lF - E ?• 4> 2i DATE Signed (� SIGNATURE of SAMPLER: %, �i� �! a ~ m Z u U i E �z �Yl'lA'I MM/06fYYJ: / i n 'Important Note, By sig" lies term you are accepting Patti s NET 30 day payraem term, and acre" to ktta charges of 1.5% per ma-ah for any invoick!Irmt paid W.,J30 days- /J J /J F-ALL-0-02Uiev.07, 15-May-2007 ATI Specialty Materials -Monroe Plant AAT1 Stormwater Monitoring Report Form Sample Date&Time:11/12/19 8:05am Stormwater Discharge Outfall #2 Sample Location: SW02 Drainage Area = 272'590sg. Ft. =6.25 acres % Impervious = 36% Person('s) Collecting Samples: Laboratory Performing Analysis: Analytical Techniques and Methods: Results of Sample Analysis: James Moser,David Ethridge,Tommy Long Pace Analytical 40 CFR Part 136 Parameter Results (mg/1) Benckmark Values (mg/1) BOD 6.8 30 COD 58.5 120 TSS 31.3 100 Cadmium ND 0.003 Chromium, total recoverable .0406 1 Lead, total recoverable ND 0.03 Nickel total recoverable .19 0.335 Zinc, total recoverable .339 0.126 Oil & Grease ND 15 H 7.3 (std units) 6-9 (std units) Storm Date: 11 /12/19 Storm Duration: 8.75 Mrs.) Inches of Rainfall: 0.75" Duration of time preceding rain event exceeding 0.1": 96 (Hrs.) . Estimated Flow Calculation: Q=CIA Q(Total)= Q(Pervious Area)+ Q(Impervious Area) Q(tot, cfs) = (.4 x inches rain/12inches/ft. x 6.25 acres x .64) + .9 x inches rain/12inches/ft. x 6.25 x .36) Q(Tota1, cfs)= .1333 X 0.75" (inches of rain) + .1688 X 0.75" (inches of rain) = 0,227 cfs STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Permit Number NCS 000330 FACILITY NAME ATI Speicalty Materials PERSON COLLECTING SAMPLE(S) Tommy Long, .lames Moser CERTIFIED LABORATORY(S) Pace Analytical Lab # 12 Lab # Part A: Specific Monitoring Requirements SAMPLES COLLECTED DURING CALENDAR YEAR: 2019 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY Union PHONE NO. 704 ) 289-4511 SIGNATURE OF PERMITTEE OR DESIGNEE REQUIRED ON PAGE 2. Outfall No. Date Sample Collected 50050 Total Flow if a Total Rainfall mo/dd/ yr MG inches SW02 1.1/12/19 0.227 0.75" Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? Oyes (F)no (if yes, complete Part B) Part B: Vehicle Maintenance Activity Monitoring Requirements Outfall No. Date Sample Collected 50050 00556 00530 00400 Total Flow (if applicable) Total Rainfall Oil & Grease (if appl.) Non -polar O&G/TPH (Method 1664 SGT-HEM), if appl. Total Suspended Solids pH New Motor Oil Usage mo/dd/vr MG inches m n mg/1 unit at/mo Form SWU-247, last revised 611212015 Page i of 2 STORM EVENT CHARACTERISTICS: Date 11/12/19 Total Event Precipitation (inches): 0.75" Event Duration (hours): 8•75 hrs. (only if applicable — see permit.) (if more than one storm event was sampled) Date Total Event Precipitation (inches): Event Duration (hours): (only if applicable — see permit.) Mail Original and one copy to: Division of Energy Mineral and Land Resources Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including thhssibili"' of fines and imprisonment for knowing violations." )a- 9-19 (Signature/¢f Permittee) /A -ot- /9 (Date) Form SWU-247, last revised 611212015 Page 2 of 2 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out thisform, please visit httl2s://deg.ne.gov/about/divisions/energy-mineral-land- resources/eneray-mineral-land-permits/stormwater-permits/nodes- industria l-sw# tab-4 Permit No.: N/C/S/0 /0 / 0/3 /3 /0 / or Certificate of Coverage No.: N/C/Gl_l—l—l-1 hl Facility Name: County: Union Inspector: David Ethridge Date of Inspection: 11/12/19 Time of Inspection: 8:18am Total Event Precipitation (inches): 0.75" Phone No. 704-289-4511 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signaturplof Permittee or Designee) 1. Outfall Description: Outfall No. SWO1 Structure (pipe, ditch, etc.): pipe Receiving Stream: Richardson Creek Describe the industrial activities that occur within the outfall drainage area: Metal Storage, Page I of 2 5WU-242, Last modified 07/28±2017 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: light gray 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy. 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stonmwater discharge, where 1 is no solids and 5 is extremely muddy: 1 2 3 4 5 7. Is there any foam in the stormwater discharge? Q Yes No. 8. Is there an oil sheen in the stormwater discharge? OYcs 0 No. _ 9. Is there evidence of erosion or deposition at the outfall? O Yes O No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may he indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 07/28/2017 T Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit https://deg.nc.gov/about/divisioiis/energy-mineral-land- resources/energy-mineral-land-Hermits/stormwater-permits/npdes-industrial-sw#tab-4 Permit No.: N/C/ S / 0 / 0 / 0 / 3 / 3 /0 / or Certificate of Coverage No.: NICIGI_I_I_l—1 /—/ Facility Name: ATI Specialty Materials - Monroe County: Union Inspector: David Ethridge Date of Inspection: Time of Inspection: 11/12/19 8:25 am Total Event Precipitation (inches): .75 Phone No. 704-289-4511 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event' is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm,event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, i certify that this report is accurate and complete to the best of my knowledge: (Signature o#Permittee or Designee) 1. Outfall Description: Outfall No. 5W02 Structure (pipe, ditch, etc.): Pipe Receiving Stream: Richardson Creek Describe the industrial activities that occur within the outfall drainage area: Metal Storage Page I of 2 5WU-242, Last modified 07/28/2017 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: light brown 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 7. 8. 9. 1 2 3 4 5 Is there any foam in the stormwater discharge? Q Yes Q No. Is there an oil sheen in the stormwater discharge? ()Yes E) No. Is there evidence of erosion or deposition at the outfall? o Yes o No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 0712812017 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please vivit htt s://de .nc. ov/about/divisions/ener -mineral-Iand- resources/energy-mineral-land-permits/stormwater-perm its/npdes-industrial-sw#tab-4 Permit No.: NIC/S/0 ,'0 / 0 /3 /3 /0 1 or Certificate of Coverage No.: NIC/GI 1_l—l—hlAl Facility Name: ATI Specialty Materials - Monroe County: Union inspector: David Ethridge Date of Inspection: 11/12/19 Time of Inspection: 8:33am Total Event Precipitation (inches): 0.75" Phone No. 704-289-4511 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event' is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signature qT Permittee or Designee) 1. Outfall Description: Outfall No. SWO_3 Structure (pipe, ditch, etc.): Pipe/Ditch Receiving Stream: Richardson Creek Describe the industrial activities that occur within the outfall drainage area: Metal Storage, Hammer Repair Dust Collection Page I of 2 sWU-242, Last modified 07l2&2017 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: light brown 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where I is no solids and 5 is extremely muddy. 1 2 3 4 5 7. Is there any foam in the stormwater discharge? () Yes No. 8. Is there an oil sheen in the stormwater discharge? ()Yes No. 9. Is there evidence of erosion or deposition at the outfall? O Yes O No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 5wU-242, Last modified 07l2812017 Kf` I r`0_ Environmentat Qualiry Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit htt s://de .nc. ov/about/divisions/eiier -mineral-land- resources/enemy-mineral-tand-permits/stormwater-permits/npdes-industrial-sw#Itab-4 Permit No.: NIC/ S /0 / 0 / 0 /3 / 3 /0 / or Certificate of Coverage No.: NIC/GI_I_l—l—l—l—1 Facility Name: ATl Specialty Materials - Monroe County: Union Inspector: David Ethridge Date of Inspection: 11 /12/19 Time of Inspection: 8:52 am Total Event Precipitation (inches): 0.75„ Phone No. 704-2894511 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event' is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: of Permittee or Designee) 1. Outfall Description: Outfall No. SW04 Structure (pipe, ditch, etc.): Pipe/Ditch Receiving Stream: Richardson Creels Describe the industrial activities that occur within the outfall drainage area: Shipping staging , turnings storage, truck loading Page I of 2 SwU-242, Last modified 07/28/2017 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: light brown 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where l is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1� 8. 9 1 2 3 4 5 Is there any foam in the stormwater discharge? Q Yes Q No. Is there an oil sheen in the stormwater discharge? ()Yes E)No. Is there evidence of erosion or deposition at the outfall? O Yes 0 No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 sWU-242, Last modified 07/28/2017 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out thus form, please visit https://deg.nc.gov/about/divisioiis/energy-mineral-land- resources/energy-mineral-land-permits/stormwater-permits/npdes-industrial-sw#tab-4 Permit No.: NIC/S/0 /0 / 0/3 /3101 or Certificate of Coverage No.: NIC/CI_I_I_I_I / 1 Facility Name: ATI Specialty Materials - Monroe County: Union Inspector: David Ethridge Date of Inspection: 11/12/19 Time of Inspection: 8:08 am Total Event Precipitation (inches): 0.75" Phone No. 704-289-4511 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR anal Office. By this signature, 1 certify that this report is accurate and complete to the best of my knowledge: (Signatur#of Permittee or Designee) 1. Outfall Description: Outfall No. 3w05_ Structure (pipe, ditch, etc.): Ditch Receiving Stream: Richardson Creek Describe the industrial activities that occur within the outfall drainage area: Metal Storage, Equipment Storage,clean empty drums, roll off containers Pagc 1 of 2 SWU-242, Last modified 07/2812017 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: light brown 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where l is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 G. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 7. S. 9. 1 2 3 4 5 Is there any foam in the stormwater discharge? Q Yes Q No. Is there an oil sheen in the stormwater discharge? ()Yes G No. Is there evidence of erosion or deposition at the outfall? O Yes O No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 5WU-242, Last modified 07/28/2017 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report Forguidance on filling out this form, please visit hitps://deg.nc.aov/about/divisions/energy-mineral-land- resourceslenergy-mineral-land-permits/stormwater-permitslnpdes-industrial-sw#tab-4 Permit No.: N/C/ S /0 / 0 / 0 /3 / 3 /0 / or Certificate of Coverage No.: N/C/GI—ITI I_I_l_l Facility Name: ATI Specialty Materials - Monroe County: Union Inspector: David Ethridge Date of Inspection: 11/12/19 Time of Inspection: 8:45arn Total Event Precipitation (inches): 0.75" Phone No. 704-289-4511 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signature ogPermittee or Designee) 1. Outfall Description: Outfall No. SW06 Structure (pipe, ditch, etc.): Ditch Receiving Stream: Richardson Creek Describe the industrial activities that occur within the outfall drainage area: parking Lot, Metal Storage, Trash Compactor Page I of 2 SWU-242, Last modified 07/28/2017 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: Very light brown 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where I is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 2 3 4 5 7. Is there any foam in the stormwater discharge? Q Yes Q No. 8. Is there an oil sheen in the stormwater discharge? ()Yes E) No. 9. Is there evidence of erosion or deposition at the outfall? O Yes O No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 5WU-242, Last modificd 07/28/2017