Loading...
HomeMy WebLinkAboutNCG030572_COMPLETE FILE - HISTORICAL_20121204NORTH CAROLINA .� Department of Environmental W6 STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO./V u(j D 3�6� DOC TYPE HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE 0 YYYYMMDD NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Wakild, P. E- Governor Director December 4, 2012 Jeff Scott Continental Automotive Systems Inc One Quality Way Fletcher, NC 28732 Dee Freeman Secretary Subject: NPDES Stormwater Permit Coverage Renewal Continental Automotive Systems, Inc. CDC Number NCG030572 Henderson County Dear Permittee: In response to your renewal application for continued coverage under stormwater General Permit NCG030000 the Division of Water Quality (DWQ) is forwarding herewith the reissued General Permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-21S.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated October 15, 2007 (or as subsequently amended). The following information is included with your permit package: • A new Certificate of Coverage (CDC) • A copy of General Permit NCG030000 • A copy of the Technical Bulletin for the General Permit • Two copies of the Discharge Monitoring Report (DMR) Form • Two copies of the Qualitative Monitoring Report Form The General Permit authorizes discharges of stormwater, and it specifies your obligations for discharge controls, management, monitoring, and record keeping. Please -review the new permit to familiarize yourself with all the changes in the reissued permit. Your facility has six (6) months from the time of receipt of the permit to update your current SPPP to reflect all new permit requirements. The first sample period of your permit begins January 1, 2013. Your facility must sample a "measureable storm event" beginning during the periods beginning January 1 and July 1 of every year (or, if applicable, report "No Flow," as outlined in Part III, Section E). Also, please note that Tier 3 Actions in Part II of your permit are triggered by benchmark exceedances on four occasions beginning on the effective date of this permit and do not count prior exceedances. The more significant changes in the General Permit since your last CDC was issued are noted either in the Draft Permit Fact Sheet that accompanied the public notice (http://portal.ncdenr.org/webLwg/wslsu/current- notices), or in the Response to Comments / Summary of Changes and Technical Bulletin documents that are posted on the Stormwater Permitting Unit's website with the new General Permit. Please visit http:/Iportal.ncdenr.orp/web/wq/ws/su/npdessw (click on 'General Permits' tab) to review that information for your specific General Permit carefully. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St Raleigh, North Carolina 27604 ''hone:91U07-63004FAY 91M07-6492 Internet www.nmaterouali', orq -! Equal Grportunity 1 Affirmnt;m , lion i mplcyer One North Carolina Awlfl'L���l, J Jeff Scott # December 4, 2012 Page 2 of 2 Some of the changes include: Part II: • Section A: The Stormwater Pollution Prevention Plan (SPPP) section, if applicable, has been updated to the most current language of our permits. Additional conditions for specific industry sectors have been added to the SPPP requirements in some cases. • Sections B, C: Failure to perform analytical stormwater monitoring may result in the Division requiring that the permittee begin a monthly sampling scheme. • Sections B, C: A lower TS5 benchmark of 50 mg/I for HQW, ORW, PNA and Tr Waters applies to these more sensitive waters. • Sections 8, C: The monitoring parameter Oil & Grease (Q&G) has been replaced by the parameter Total Petroleum Hydrocarbons (TPH) for vehicle maintenance areas, and in some cases, other analytical monitoring requirements. • Sections B, C, D: Inability to sample due to adverse weather must be recorded in the SPPP, or in separate on -site records if your General Permit does not require an SPPP. Adverse weather is defined in the "Definitions" section of the permit. • Sections B, C: The term "Representative Storm Event" has been replaced by "Measurable Storm Event." A measurable storm event is defined in the permit. • Section D: If the permittee fails to respond effectively to problems identified by qualitative monitoring, DWQ may require the permittee to perform corrective action. Please review Parts III and IV to understand the Standard Conditions of your new NPDES General Permit, including Compliance and Liability, Reporting, Monitoring and Records requirements; Operation and Maintenance obligations; and Definitions. Please note that all samples analyzed in accordance with the terms of this permit must be submitted to the Division on Discharge Monitoring Report (DMR) forms available on the Stormwater Permitting Unit's website above. DMR forms must be delivered to the Division no later than 30 days from the date the facility receives the sampling results from the laboratory. Also note that existing permittees do not need to submit a renewal request prior to expiration unless directed by the Division. Your coverage under the General Permit is transferable only through the specific action of DWQ. This permit does not affect the legal requirements to obtain other permits which may be required by DENR, nor does it relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package, please contact the Division's Stormwater Permitting Unit at (919) 807-6300. Sincerely, for Charles Wakild, P.E. cc: DWQ Central Files Stormwater Permitting Unit Files Asheville Regional Office STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG030000 CERTIFICATE OF COVERAGE No. NCG030572 STORMWATER NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Continental Automotive Systems Inc is hereby authorized to discharge stormwater from a facility located at: Continental Automotive Systems, Inc. One Quality Way Fletcher Henderson County to receiving waters designated as FRENCH BROAD RIVER, a class B waterbody in the French Broad River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, and IV of General Permit No. NCG030000 as attached. This certificate of coverage shall become effective December 4, 2012. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this 41h day of December, 2012. for Charles Wakild, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission HCDE R North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary April 30, 2010 Robert G. Nelson Continental Automotive Systems, Inc - I Quality Way Fletcher, NC 28732 Subject: NPDES General Permit NCG030000 Certi ficate' of Coverage NCG030572 Continental Automotive Systems Formerly Continental Teves, Inc. Henderson County Dear Mr. Nelson: On February 1, 2010, Division personnel received your request to revise your stortnwater pemlit Certificate of Coverage to accurately include you new company name. Please find enclosed the revised Certificate of Coverage. The terms and conditions contained in the General Permit remain unchanged and in full effect. 'I'lills revised Certificate of Coverage is issued under the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency. If you have any questions, please contact the Stormwater Permitting Unit at 919-807-6300. Sincerely, oRiGINAL SIGNED GN KEN PICKLE Coleen H. Sullins cc: DWQ Central Files Asheville Regional Office Stormwater Permitting Unit Wetlands and Stormwater Branch 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N, Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807.63001 FAX: 919-807-64941 Customer Service: 1-877.623-6748 Internet, www.nmaterquality.org An Equal opportunity IAifirmaVye Action Employer NorthCarolina Natul"allif t _ 9. STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCE'S DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG030000 CERTIFICATE OF COVERAGE No. NCG030572 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Continental Automotive Systems, Inc. is hereby authorized to discharge storntwater from a facility located at Continental Automotive Systems, Inc. I Quality Way Fletcher Henderson County to receiving waters designated as a' UT of the French Broad River, a class B water, in the French Broad River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, 11, III, 1V, V and VI of General Permit No. NCG030000 as attached. This certificate of coverage shall become effective April 30, 2010. This Certificate of Coverage shall remain in effect for the duration of the Gcneral Permit. Signed this day April, 30, 2010. Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission & WArE� Michael F. [Easley, Governor C1� QG State of North Carolina William G. Ross, Jr., Secretary Department of'Environment and Natural Resources pColeen H. Sullins., Director ._. Division of Water Quality November 21, 2008 Lisa Foster -Morrow Continental Automotive Systems One Quality Way Fletcher, NC 28732 Subject: Representative Outfall Status Request N11DES Stormwater Permit Permit No: NCG030572 Continental -Henderson Plant Henderson County Dear Ms. Foster -Morrow: Asheville Regional Office staff have reviewed your Representative Outfall Status Request dated November 20, 2008 for stormwater discharges related to NPDES NCG030572 held by Continental Automotive Systems facility at 1 Quality Way, Fletcher, NC. Based onthe information provided and the site visit and evaluation conducted on November 20, 2008, your request is approved. In accordance with 40 CFR § 122.21(g)(7), you are authorized to sample stormwater discharge outfall (SDO) numbers 1 and 4 as representative of facility stormwater discharges. This approval is effective with the next sampling event. We also want to remind you that the permit still requires Qualitative Monitoring be performed at all SDOs, regardless of representative status. Please remember that any actions you initiate in response to benchmark exceedances as directed in the tiered response provisions of your permit must address all drainage areas represented by SDO 1 and 4, as appropriate. Please append this letter to your Storniwater Pollution Prevention Plant (SPPP) or permit to document that representative otltfall status has been approved. If changes in drainage areas, structures, processes, storage practices, or other activities occur that significantly alter the basis of this approval, representative outfall status may no longer be valid. You should either resume sampling at all SDOs, or reapply to this office for representative outfall status based on updated information. If you have any questions or comments concerning this letter, please contact Chuck Cranford at (828) 296-4500 or at eliuck,cranford @ncmail.net. Sincerely, 1 Roger Edwards Regional Supervisor Surface Water Protection cc: ARO files Central OfficelStormwater Permitting Unit Central files No thCarolina ,ntrrrally North Carolina Division of Water Quality 2090 U.S. I Fghway 70 Swannanoa, NC 28778 Plione (828) 296-4500 Customer Service lnlernel www.ncwat®rquality.org FAX (828)299-7043 1-977.623-67,18 An Equal Opportunity/AttirmaGve Action Employer-5D%a Recycled110%Po5l Consumer Paper G:IWPDATAtiDEMWQIHendersonlStonnwaler Fabricaled Metal NCG031ContinentalTeves—ROS—Letter_11-20-06.doc Compliance Inspection Report Permit: NCO030572 Effective: 06/06/08 Expiration: 10/31/12 Owner: Continental SOC: Effective: Expiration: Facility: Continental -Henderson Plant County: Henderson One Quality Way Region: Asheville Fletcher NC 28732 Contact Person: Lisa Foster Title: Phone: 828-654-2240 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Dale: 11120/2008 Primary Inspector: Chuck Cranford Secondary inspector(s): Certification: Phone: Entry Time: 12:30 PM Exit Time: 01:30 PM Phone: Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Metal Fabrication Stormwater Discharge COC Facility Status: ® Compliant ❑ Not Compliant Question Areas: IM Storm Water (See attachment summary) Page: 1 Permit: NCGO30572 Owner -Facility: Continental Inspection Date: 11120/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: DWQ staff was met on site by Lisa Foster -Morrow. A tour was conducted of the exterior of the facility, where stormwater conveyances and outfalls and site conditions were observed. During the visit, the SPPP manual was reviewed, operational activities and existing stormwater exposures were discussed. Permit requirements were also reviewed as pertaining to the most recent permit version. At the time of the inspection the site was found to be in comptiance with the permit. The inspector noted that the facility appears to maintain good housekeeping practices and records were found to be in good order. The site is a good candidate for a No Exposure Certification, if areas of pallet, dumpster and equipment storage were roofed. The permittee has applied for representative outfall status. The inspector supports the monitoring change. Upon evaluating the facility's stormwater drainage areas and conveyances, it was determined that Outfalls I and 4 suffuciently represent the stormwater discharges of the site_ Page: 2 Permit: NCGO30572 Owner - Facility: Continental Inspection Date: 11120/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ■ ❑ Cl ❑ # Does the Plan include a General Location (USGS) map? ■ ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ■ ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ■ ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ■ ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ■ ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ■ ❑ ❑ ❑ # Does the Plan include a BMP summary? ■ ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ ❑ ❑ ❑ # Does the facility provide and document Employee Training? ■ ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ■ ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ■ ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ■ ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ■ ❑ ❑ ❑ Comment: Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ ■ ❑ ❑ Comment: New permit as of June 2008. Permittee within grace period for sampling. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? - ❑ ■ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ■ ❑ ❑ Comment: New permit as of June 2008. Permittee within grace period for sampling. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ■ ❑ ❑ ❑ # Were all outfalls observed during the inspection? ■ ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ■ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ■ ❑ ❑ ❑ Comment: Facility has applied for repsresentative outfall status. The inspector supports such a change. Page: 3 wA r69Q� 1 JI► r� r -tz„ ire>. .tune 6, 2008 Ms. Lisa Foster -Morrow Continental One Quality Way Fletcher, NC 28732 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Colleen H. Sullins, Director Division of Water Quality Subject: General Permit No. NCG030000 Continental Henderson Plant COC NCG030572 Henderson County Dear Ms. Morrow: In accordance with your application for a discharge permit received on May 22, 2008, we are forwarding herewith the subject certificate of coverage to discharge under the subject state — NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143- 215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please take notice that this certificate of coverage is not transferable except after notice to the Division of Water Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other federal or local governmental permit that may be required. If you have any questions concerning this permit, please contact Robert Patterson at telephone number (919) 733-5083 ext. 360. Sincerely, ORIGINAL SIGNED BY KEN PICKLE for Coleen H. Sullins cc: Asheville Regional Office, Starr Silvis, P.E. Central Files Stormwater Permitting Unit Files ore la,c:��r�lin:, North Corolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-5083 Customer 5ervicd Internet: w+.�w.ncwa er�aLtv.ore Location: 512 N. Salisbury St, Raleigh, NC 27604 Fax (919) 733-9612 1-877-623.6748 An Equal Opportunity/Affirmative Action Employer — 50% Recyded110% Post Consumer Paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCGO30000 CERTIFICATE OF COVERAGE No. NCGO30572 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Continental is hereby authorized to discharge stormwater from a facility located at Continental Henderson Plant One Quality Way Fletcher Henderson County to receiving waters designated as a UT of the French Broad River, a class B water in the French Broad River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I,1I, III, IV, V, and VI of General Permit No. NCG030000 as attached. This certificate of coverage shall become effective June 6, 2008. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this 6`h day of June, 2008. ORIGINAL SIGNED BY KEN PICKLE for Coleen H. Sullins., Director Division of Water Quality By the Authority of the Environmental Management Commission r, . i f• 3 � yS•• J fill TolA ALLEREG AIR 1° n �'• � 65 � /(��� ``•� � "U • 7 '' `+� ' LG f ^ �'IJ:o r \ : a �' `^y,,5.; - k 7L .,r ��`✓J' ¢.s N\ ��'il 1/ t; _�,.. �'�- �' Vie• lye'' Continental Henderson Plant _ l� � � �,-� f t 4�..:�} �'�`� � '�j `�;s•�•;y-'` g 1 �.�i�`� `'-�' � "tiO5fl�,._ it •tea � \ �_ �„_�—'j ^ f . Fe zZ� �� r Jou F.° �� ���` o• I �n `7. �j r' J r f •`x ` � B � ' L �r f't �s 'c\• ` \,b � _ ti ,�t1If-+lil`d•�,,ac.,A3:• a �'- 20 •4�� �j VV { �1� �'i",.- •%/� �- a.s�'� 'I'y `JJ'_�l• �V'/ ++ ROAD ��pe ' r1i jr w U 29 »i f 'i ,1a%r ,�/ `1kL` f� I A _ a 0 �� +! Buller Bridge 0 �y ��r � ; �•�,� ' - , ' a `'��.^,�,�r ,•;� - a j f�., + ( 7. '�, b � `� �.y 0 � ! ` '�. c.: ".. _ ;� �n. i �t x+►'= 'mow JFtiF' �1 % �. . ■er •' 4'311�� `� 1 ���' � !_� p � � Q .'li�.�� �• R NCG030572 N w E .S. MapScale1 : 24, 000 Continental Continental Henderson Plant Latitude: 350 25' 04" N Longitude: 820 32' 42" W County: Henderson Receiving Stream: LT of French Broad River Stream Class: B Sub -basin: 04-03-02 (French Broad River Basin) Facility Location Rc: NCG030572 - Continental Henderson Plant, Henderson County Subject: Re: NCGO30572 - Continental Henderson Plant, Henderson County From: Starr Silvis <Starr.Silvis@ncmail.net> Date: Wed, 04 Jun 2008 11:09:05 -0400 To: Robert Patterson <Robert.Patterson@ncmail.net> CC: Chuck Cranford <chuck.cranford@ncmail.net> I do not have any concerns, but am not familiar with the site. Unless you think a site visit is warranted, I say go ahead and issue the permit and we will inspect later. Thanks! Robert Patterson wrote: Starr, Please see NOl attached. We have received an application for coverage of an existing facility under NCG 03 from Continental Automotive Systems for their Henderson Plant. The facility drains to a UT of the French Broad River (class B) in Fletcher (Henderson County). They do not have vehicle maintenance. They are a large quantity generator. Their operation includes machining, assembly, and plating. Does the ARO have any concerns about issuing this facility a COC for this general permit? Thanks! Starr Silvis, P.R. - Starr.Sil.vis@ncmail.net Environmental Engineer Forth Carolina Dept. of Environment and Natural Resources Asheville Regional Office Division of water Quality -- Surface water Protection Section 2090 U.S. 70 Highway Swannanoa, NC 26778 Tel: 828-296-4500 Fax: 828-299-7043 "If there is magic on this planet, it is contained in water." Loren Eiseley Starr Silvis, P.E. <Starr.Silvis a,ncmail.net> NC DENR - Asheville Regional Office Division of Water Quality - Surface Water Protection Section iI of 1 6/4/2008 1 1:14 AM 1 ` 4tMACTEC engineering and constructing a better tomorrow February 6, 2008 Mr. Bradley Bennett Stormwater Permitting Unit Division of Water Quality 1617 Mail Service Center Ralei- , North Carolina 27699-1617 Subject: Notice of Intent for NPDES Coverage, NCG030000 Continental Henderson Plant Fletcher, North Carolina MACTEC Project 6686-08-1739 Dear Mr. Bennett: MACTEC Engineering and Consulting, Inc. (MACTEC), on behalf of Continental Automotive Systems, is pleased to submit this Notice of Intent (NOI) to obtain coverage under North Carolina General Permit NCG030000, in accordance with the National Pollutant Discharge Elimination System (NPDES), for the Continental Henderson Plant located at One Quality Way in Fletcher, North Carolina. The NCG030000 offers coverage under the NPDES to facilities that have stormwater discharges associated with activities classified as Transportation Equipment (SIC 37). Included with this submittal is the NOI application with a site location map (Figure 1) and approximate property boundary map (Figure 2). The Continental Henderson Plant is an approximate 250,000 square -foot facility located on an approximate 40-acre site in Fletcher, North Carolina. The facility was originally constructed in 1997 and several renovations and additions have been completed since that time. Currently, automotive brake calipers are manufactured at the facility and operations include machining and assembly. Continental plans to launch a plating line in"March 2008. MACTEC is submitting three copies of the NOI as well as associated attachments as requested within the NOI application. If you have questions concerning this NOI, please contact Kerry Reed at (704) 357-8600. Sincerely, MACTEC ENGINEERING AND CONSULTING, INC. Vrry'ATRWeE. �.Matthew E. Wallace, P.E. Project Engineer for � � bi-d Principal Engineer with permission Attachments: NOI Application Figure 1: Site Location Map Figure 2: Approximate Property Boundary Map MACTEC Engineering and Consulting, Inc. 1308 Palton Avenue • Asheville, NC 28806 • Phone: 828.252 8130 0 Fox: 828.251 9690 www.mociec.com Division of Water Quality ( Water Quality Section !rational Pollutant Discharge Elimination Systern NCG030000 NOTICE OF INTENT FOR AGIIM-Y USE; ONIA Batt Iirccwcd 1'c;u i (wll Um O enili: slOs I' Cnrrnu� ]l Q Check F% .` flltlul 1 Penni€ As"NUe1I It' rSn� National Pollutant Discharge Elimination System application for coverage under General Permit NCGO30€ 00: STORIViWATER DISCHARGES associated with activities classified as: SIC 335 Rolling. Drawing: and Extruding of Nonferrous Metals SIC 3398 Heat Treating of Metal SIC 34 Fabrication of Metal Products SIC 35 Industrial and Commercial Machinery SIC 36 Electronic Equipment SIC 37 'Transportation Egbiprnent SIC 38 Measuring and Anaiyzing Instruments ' Standard Industrial,ClasslficatiDn Cade (Please print or type) 1) Mailing address of owner/operator: Name Street Address O►N C. Q v -A i A-v_ Way _ _ _- City Fief ctir:r_ _ State N c- Zip Code Z B73Z. Telephone No. g L 8 65` - Zovo Fax: 52 B _�S`i - 2.a50 2) Location of facility producing discharge: Facility Name (- ti VN Vi n 0,, 'A- a Facility Contact Street Address City County Telephone No. Address to which all permit correspondence will be mailed MS . U 4n Pe) r - Ntorm..� S:*�,.: yr tr H C O r c Qu -.k,+V Wow Ft CAc.h c-,r State t,� L ^ ZIP Code . 2$?32 %2 S ioSLk - LZ-4'oFax: 52$ fv5` - ZZ"i 3 3) Physical Location Information: Please provide a narrative description of how to get to the facility (use street names, state road numbers. and distance and direction from a roadway intersection). (Fro,r 1Z lc.:,��) Tc+kt =-r4o +ta 5-2.6E-= �Akt � l,� 40 t-VW&IrAS �K"e1�l,i4t ee-4-A e7"n l 400rrk /AvAr— " 'ii;r._ 1 &7 So to copy of a county map or USGS quad sheet with faC+lily clearly located on the mep is feQuired to be submitled with this applica!ion) (�vc+1.C. W-.Y a�Z }ilne (:,o..�r+..Gv>�-s.l nc�[rs... P1oX.,F Oker cn f-.-11hi 4) This NPDES Permit Application applies to which of the following : u New or Proposed Facility X, Existing Bate operation is to begin Page 1 of 3 SW u-2 t 8-083002 NCG030000 N.O.I. 5) Standard Industrial Classification: Provide the 4 digit Standard tnduslrial Classification Cade (SIC Code) that describes the primary industrial activity at this facility SIC Code: 3 T 6) Provide a brief narrative description of the types of industrial activities and products. manufactured at this'faciiity: T%'se 'AV4 (�«L59+1� P~$�Gel4 SIMG�w SriY �Au 1nr r�lr �-'.r - fir Carr-tz Zr 7) Discharge points / Receiving waters: How many discharge points (ditches, pipes: channels. etc,( convey stormwater from the property? 6 What is the na€rie of the bodv or bodies of water (creek, stream, river; lake, etc.) that the facility stormwater discharges end up in?y�_3Plr+_m� rtica�,t at L4_ of r-r"1" C"� ; vim✓ If the site stormwater discharges to a separate storm sewer system. name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). t�/ k -- 8) Does this facility have any other NPDES permits? No ❑ Yes If yes, list the permit numbers for al! current NPD-S permits for this facility: 9) Does this facility have any Non -Discharge permits (ex.. recycle permits)? No Yes if yes, list the permit numbers for all current Non -Discharge permits for this facility: 10) Does this tacility employ any best management practices for stormwater control? C No ER, Yes If yes,. please briefly describe: _ "� '^ 11) Does'this facility have a Stormwater Pollution Prevention Plana? C No (-'o \o,- ae-v1:\-Pe4� ❑ Yes If yes, when was it implemented? 12) Are vehicle maintenance activities occurring at this facility? W No ❑ Yes 13) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment: Storage, or Disposal Facility? & No ❑ Yes b) Is this facility a Srnati Quantity Generator (less than 1000 kg. of hazardous waste generated per month; of hazardous waste? ® No ❑ Yes Page 2of3 SWU-21 n-c43002 NCG030000 N.O.L c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of hazardous waste? ❑ No CK Yes d) If you answered yes to questions b. or c., please provide the following information: 1 Type(s) of waste: dsE� F�� -CAS �5o1, _ _Dt1_ W-3,Ga� C� ,12�w►�, 1 .n w�� � 1 How is material stared: 2,5_S., l -ivFta b, 55 t d,r,,, 'k: Where is material stored: ��.O' How many disposal shipments.per year: rox. 1Z Name of transport 1 disposal vendor: �. � ,]a�.;v —' I L a. ~ rn`lr ? Vendor address: f 10 14) Certification: C\"CZ 04V\*C " T v-1 3 `fit Gin �Arin � , V A 214 53 i North Carolina General Statute 143-215.6 b (i) provides that: Any person who knowingly makes any false staternerl, representation. or certification in any application, rocurd, report. plan or other document filed or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsities, tampers with or knowingly renders inaccurate any recording or monitoring device or metnod required to be operated or maintained under Article 21 or regutations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a line not to exceed $10,000, or by imprisorrnent not to exceed six 'nonths, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $10.000 or imprisonment not more than 5 years. or both. for a similar offense.) I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I certily that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: OtOe.r Title: (Signature o(Applicant) _z /"J'� - (D to igned) A check or money order must accompany notice of intent for.$100.00 made payable to: NCDENR Final Checklist This,appli cation will be returned as incomplete unless all of the following items have been included: LCheck for $100 made payable to NCDENR This completed application and ail supporting documents V Copy of county map or USGS quad sheet with location of facility clearly marked on map Mail the entire package to: Stormwater Permitting Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Note The submission of this document does not guarantee the issuance of an NPDES permit. Page 3 of 3 swk�u-21£i-oa�a©� x • �EG1L�1A �. SyCkShoils Al E ,;.Ir •�ylr 1. � 4 - i • 00 ' fY l.�f�r I IL 5-q\\ IMATE CATION f . I li r t• i t [� -r`f� 4l 1 ,yam' • ,•ti. �- w' EXPLANATION 0 APPROXIMATE LOCATION OF PROJECT SITE BOUNDARY 2" loan o 2" APPROXIMATE LOCATION OF INTERPROLATED HWY 280 APPROXIMATE SCE IN FEET ouAonANME LOGITION 21 REF.: U.S.G.S, 7.5 MINUTE TOPOGRAPHIC MAP OF SKYLANO, N.G. QUADRANGLE, DATED 1965; PHOTOREWSED 1991. A MACTEC CONTINEENN E HENDERSON PLANT EK04EERMC & f&k TINC. INC ONE QUALITY WAY CHARLOTTE, NORTH CAROUNA FLETCHER. NORTH CAROLINA RFPARED y DATE SlZb1D6 CHECKED,,�X DATE Z ��o� roe NO. 6b86-08-5739 FIGURE 1 d l f •1 i f 1r, I E E c v Y N 0 s OWL c s 0 EXPLANATION APPROXIMATE LOCATION OF SITE BOUNDARY s 0 N N 0 W REF.: AERIAL PHOTOGRAPH OF BUNCOMBE COUNTY, NC CIS (GEOGRAPFNC INFORMATION SYSTEM) ON-LINE SERVICES. 'JI l APPROXIMATE PROPERTY BOUNDARY MAP ` �J M AC T1-(` CONTINENTAL HENDERSON PLANT 0 ENGIMER'NG & COHSCx.11K. WC ONE QUALITY WAY CHARLOTTE. NORTH CAROLINA FLETCHER, NORTH CAROLINA %i REPAIRED DATE CHECKED DATE JOB NO. fClf7E a Y mo 1) z41al, oAW..a 2j1�o6 6685-081739 MACTEC Engineering and Consulting, Inc. I Patton Avenue Asheville,4rMACTEC North Carolina 28806 Phone: (828) 252-8130 Fax: (828) 251-9690 LETTER OF TRANSMITTAL TO: Mr. Bradley Bennett DATE: 5/19/08 z `� Stormwater Permitting Unit PROJECT NO.: 6686-08-1739 m Division of Water Quality PROD. NAME: Continental Automotive 1617 Mail Service Center SUBJECT: Notice of Intent for NPDES. Coverage :- n Raleigh, North Carolina 27699-1617 WE TRANSMIT TO YOU: N HEREWITH El UNDER SEPARATE COVERT u D � SUBJECT: ACTION: SENT BY: ❑DRAWINGS ❑FOR YOUR INFORMATION ®MAIL; ❑SPECIFICATIONS ®FOR YOUR COMMENT OR APPROVAL ❑CERTIFIED MAIL ❑CALCULATIONS ❑RETURNED FOR CORRECTION: RESUBMIT ❑EXPRESS ❑REPORT ❑APPROVED AS NOTED ❑COURIER ❑COST ESTIMATE OAS REQUESTED [—]RAND DELIVERED ®AS NOTED ❑FACSIMILE: tlot. iuunig uanannuai ancct/ COPIES DATE DESCRIPTION 2 2/6/08 Notice of Intent for NPDES Coverage. NCG030000 — Continental Automotive, Fletcher. North Carolina REMARKS: Mr. Bennett, Enclosed are two copies of a NO] for the Continental Automotive facility in Fletcher, North Carolina, along with the S100 fee. Please do not hesitate to call if there are any questions. Thank you. Matt CC: File By: Matthew E. Wallace KVJ— Ms. Lisa Foster -Morrow. Continental Automotive (w/o enc.) Phone: 828-252-8130 File (1) CONFIDENTIALITY NOTICE: This message is intended only for the use of the individual or entity to which it is addressed. and may contain information that is privileged, confidential, and exempt from disclosure under applicable law, Irthc reader of this message is not the intended recipient, or the employee or agent responsible for delivering the message to the intended recipient, you are hereby notified that any dissemination, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please notify us immediately by telephone and return the original message to us at the above address via the U.S. Postal Service. Thank you. If transmission is not received in good order, please call (828) 252-8130 1)(XVft ems Nffm Hevixed l aIM 0: