Loading...
HomeMy WebLinkAboutSW6200403_1356-Storm Outlets_4/30/2020OUTLET PROTECTION DATE DESIGN PHASE DESIGN 04-09-20 PRELIM / / PROJECT NAME PROJECT NO CONSTR / X / Fayetteville Clinton Road Dollar General 1356 REVISION / / LOCATION BY RECORD / / Fayetteville, North Carolina CSB OTHER / / CHECKED BY (SPECIFY) 0 Storm Outlet Structure FES No.= PO-2 Q10/Qfull =0.70 Pipe Dia= 15 in V/Vfull = 1.08 Q10 =3.81 cfs V = 4.8 fps Qfull = 5.47 cfs Vfull = 4.45 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2:D50 =8 in DMAX =12 in Riprap Class = B Apron Thickness = 18 in Apron Length = 7.5 ft Apron Width @ Outlet = 3.75 ft Apron Width @ End = 8.8 ft Storm Outlet Structure FES No.= OUTLET Q10/Qfull =0.59 Pipe Dia= 10 in V/Vfull = 1.04 Q10 =1.45 cfs V = 4.7 fps Qfull = 2.47 cfs Vfull = 4.53 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2:D50 =8 in DMAX =12 in Riprap Class = B Apron Thickness = 18 in Apron Length = 5.0 ft Apron Width @ Outlet = 2.5 ft Apron Width @ End = 5.8 ft 1356-Storm Drainage.xls LATEST REVISION: 4/30/2020 7:48 AM PAGE 1 OF 2 OUTLET PROTECTION DATE DESIGN PHASE DESIGN 04-09-20 PRELIM / / PROJECT NAME PROJECT NO CONSTR / X / Fayetteville Clinton Road Dollar General 1356 REVISION / / LOCATION BY RECORD / / Fayetteville, North Carolina CSB OTHER / / CHECKED BY (SPECIFY) 0 Storm Outlet Structure FES No.= FES-4 Q10/Qfull =0.82 Pipe Dia= 18 in V/Vfull = 1.11 Q10 =7.00 cfs V = 5.3 fps Qfull = 8.52 cfs Vfull = 4.81 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2:D50 =8 in DMAX =12 in Riprap Class = B Apron Thickness = 18 in Apron Length = 9.0 ft Apron Width @ Outlet = 4.5 ft Apron Width @ End = 10.5 ft 1356-Storm Drainage.xls LATEST REVISION: 4/30/2020 7:48 AM PAGE 2 OF 2