Loading...
HomeMy WebLinkAboutSW3191203_Supplement-EZ Form_20200206SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Trinity Ridge subdivision Sect 2 2 Project Area ac 10.61 0 3 Coastal Wetland Area ac 4 Surface Water Area ac 0 5 Is this project High or Low Density? Low 6 Does this project use an off -site SCIVI? No WITH 02H .1003(4) 7 lWidth of vegetated setbacl 8 Will the vegetated setback 9 Ils BUA other that as listed in .1003 4 c d out of the setback? I NIA 10 Ils streambank stabilization proposed on this project? I NIA NUMBER AND TYPE OF SCMs: 11 Infiltration System 0 12 Bioretention Cell 0 13 Wet Pond 0 14 Stormwaler Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Bayfilter 0 26 IFilterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Kevin E. Herring PE 28 Or anization: Kevin E. Herring En ineerin 29 Street address: 16101 Silver Rd 30 City, State Zip: Oakboro NC 28129 31 Phone numbers : 980-621-0935 32 1 Email: kevin@kevinherringengineering.com Certification Statement: I certify, under penalty of law that this Supplement-FZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. CARO<i•f•, _ SEAL 20165 _ Si re of Designer � y .2azo Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so, number of drainage areas/SCMs 1 3 Is all/part of this project subject to previous rule versions? I No CLICK TO LOAD FORM DRAINAGE AREA INFORMATION Entire Site 4 Type of SCM Vegetative Swale 5 Total BUA in project (sq ft 110614 sf 6permitting) New BUA on subdivided lots (subject to s ft 79200 sf 7permitting) New BUA outside of subdivided lots (subject to s 31414 sf 8 JOfFsite -total area (sq ft 9 Offsite BUA (sq ft 10 Breakdown of new BUA outside subdivided lots: - Parking (sq ft 4160 sf -Sidewalk (sft - Roof (sq ft - Roadway s ft 27200 sf - Future (sq ft - Other, please specify in the comment box below (sq ft 54 sf 11 New infiltrating permeable pavement on subdivided lots (sq ft _ New infiltrating permeable pavement outside of subdivided lots (sq ft 12 13permitting) Exisitng BUA that will remain (not subject to s ft 14 Existing BUA that is already permitted (sq ft 15 Existina BUA that will be removed (sq ft 16 Percent BUA 23.93% 17 Design storm inches 18 IDesign volume of SCM cu ft 19 lCalculation method for design volume DITIONAL INFORMATION Please use this space to provide any additional information about the 20 drainage area(s): 54sf OTHER BUA is concrete pad used for Cluster Mailbox Driveways in R/W Vew 20' Street LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H .1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per .1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances (H:V) <_ 3:1 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 2.16 fps 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s) (%) 8 Bottom width of curb outlet swale(s) (feet) 9 Maximum side slope of curb outlet swale(s) (H:V) 10 Minimum length of curb outlet swale(s) (feet) 11 Are treatment swales used instead of curb outlet swales? 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 JAre variations to rule .1003 proposed? No ADDITIONAL INFORRMTION 15 1 Please use this space to provide any additional information about this low density project: Rooadside ditches to be utilized for required treatment conveyances. Drainage Pervious Swale BUA Q Slope Va„ow Vac[ual # Area (ac) area C (cfs) (%) (fps) (fps) Flow depth (ft) ac ac 0.37 1 0.22 Varies 0.50 0.84 1.50 4.50 1.38 2 1.09 Varies 0.50 4.24 1.00 4.50 1.78 0.76 3 1.30 Varies 1 0.50 1 5.03 1 1.50 1 4.50 1 2.16 1 0.75 4 5