Loading...
HomeMy WebLinkAboutSWA000060_(7 )Cameron Woods - Details_10/21/2019BRASS MARKER PLATE MARKED PLATE WITH ANCHOR 3/4" CHAMFER AT M EA. CORNER V CAST THE LETTERS "MV" IN ONE FACE OF THE CONCRETE 4 #3 BARS MARKER AND ORIENT TOWARD o THE ROADWAY ROTATE MARKER TO OTHER END FOR BLOW -OFF VALVE NO. 8 1zo f4" SO. PRECAST CONIC. POST (4000 P.S.I.) 25 FT. PLATE WITH VALVE NUMBER, DIRECTIONAL ARROW -POINTED TO MARKED VALVE & DISTANCE TO THE NEAREST FOOT. TYPICAL VALVE MARKER DETAIL W NO SCALE 1 NOTES: PAINT MARKER BLUE AFTER INSTALLATION THRUST BLOCKING PE PLASTIC TO PROTECT TAPPING SLEEVE f '. TAPPING VALVE WITH VALVE BOX EXISTING WATER MAIN TAPPING SLEEVE SHALL BE ROMAC BRAND MODEL SST MANUFACTURED WITH 316 STAINLESS STEEL. NEW WATER MAIN TYPICAL TAPPING SLEEVE AND VALVE ASSEMBLY DETAIL NO SCALE -D GRADE e e 2„ C BACKFILL TO EDGE � IIII—III I I �' PRECAST CONCRETE PROTECTION RING AS SHOWN PRECAST CONCRETE STEAMER z EDGE CONNECTION Q w ON PLANS PROTECTION RING o OF ROAD Q 2 1/2" HOSE CONNECTION — 6" G.V. & BACKFILL- 6" WATER C. I. BOX LINE STONE VALVE Box VALVE OPERATOR NUT (7 C.F. MIN.) TYPICAL VALVE BOX DETAIL(W NO SCALE 2 / VALVE BC 6" LOOPED BOX PIE IN BOX PLACE EMPTY VALVE BOX AT INTERVALS WHERE iACER WIRE R VALVES DO NOT OCCUR & PLACE TRACER WIRE IN BOX. NOTE: NO. 1 DRILL HOLE IN VALVE BOX PRECAST CONCRETE PROTECTION RING FOR TRAC WIR BACH t FINISHED GRADE NOTE: AT PIPE INTERSECTIONS, MULTIPLE VALVES, RUN WIRE UP AT ONLY ONE VALVE. SINGLE 12 AWG SOLID CORE WIR BOX P.V.C. PIPELINE ij//\J�—GATE VALVE TRACER WIRE TO BE LAID UNDERNEATH WATER LINE "'.' ' __MASONRY BLOCK TYPICAL TRACER WIRE INSTALLATION DETAIL NO SCALE NOTES: 1. DRILL HOLE IN VALVE BOX TO INSERT TRACER WIRE,BRING UP TO INSIDE AND ROLL UP AT LEAST 6"-8" EXCESS 2. PLACE TRACER WIRE IN VALVE BOX AT 1,000" INTERVALS OR AS NOTED ON THE PLANS, TYPICAL. 3. DO NOT SPLICE WIRE WHEN BEGINNING A NEW SPOOL. INSTEAD INSTALL A VALVE BOX AND ATTACH EACH WIRE WITH A BRASS SCREW TO THE VALVE BOX. BRICK SUPPORT ON EACH SIDE :. OF PIPE TO BE ae... e 2" aA.. e 1" a s r °° (- VALVE BOX THREADED COUPLING RE REA.."::,.TAMPED BACKFILL :;1):` VALVE NUT ONLY ECHANICAL JOINT " WITH GRIP RING BRASS PIPE NIPPLE 2" DIA RICK TO OR LONGER TO BRING PIPE SUPPORT UP TO FINISHED GRADE THREADED VALVE BOX PIPE NIPPLE MIN 18" PIPE NIPPLE 2" DIA < 4: MIN. 1/3 C.Y. AT 3000 P.S.I. . A MASONRY BLOCK END CAP WITH 2" THREADED PORT TYPICAL PERMANENT BLOW -OFF ASSEMBLY DETAIL W NO SCALE 4 NOTE: SEE TYPICAL VALVE BOX DETAIL FOR BRICK INSTALLATION I 0 w U a V) Q DO CONIC. N BLOCKING (SEE NOTE) WEEP HOLE TO 6" HYDRANT TEE 4-3/4" TIE RODS WITH BRACKETS (SEE DETAIL) NOTE: MASONRY BLOCK 1 .)TIE HYDRANT TO MAIN LINE W/TIE RODS IN LIEW OF CONC. BLOCKING IN SANDY SOIL. 2.)MECHANICAL JOINTS USED WITH GRIP RINGS TYPICAL FIRE HYDRANT INSTALLATION DETAIL NO SCALE NOTES: 1. CONCRETE SHALL BE 3,000 PSI MIN. 2. CONCRETE FOR THRUST BLOCKING SHALL BE KEI FAIRLY DRY, THUS MAKING THE CONCRETE WEDC SHAPE MORE EASILY FORMED WITH THE WIDEST PART (BLOCKING AREA) AGAINST UNDISTURBED 3. NO CONCRETE SHALL COVER ANY BOLTS OR GLA 4. ALL PIPING AND ACCESSORIES TO BE WRAPPED WITH 10 MIL. POLYETHYLENE PRIOR TO POURINC BLOCKING. 5. VOLUME OF THRUST BLOCKING SHALL BE AS SHI ON THE THRUST BLOCKING SCHEDULE. MIN.1/3 C.Y. AT 3000 P.S.I. HYDRANT TEE PLAN TEES PLAN BENDS 18" MIN. f 01 1n En J" 0 OR LESS �f 24" MIN. - 12" 0 OR LESS a��►_ll�til9�� PIPE 90' BEND 45' BEND 221/2BEND 11/4' BEND TEE PLUG SIZE A TB A B A B A B A B C D 4" 8" 12" 8» B. 6" 6" 6" 6" B" 9" 10" 16" 6" 10" 12" 8" 10" 8' 8" 8" 8" 10" 10" 12" 18" 8" 15" 13" 10" 10" 8" 8" 8" 8" 10" 12" 12" 24" 10" 16" 14" 10" 12" 6" 10"1 6" 10" 1 11" 14" 1 14" 25" 12" 20" 16" 12" 14" 18" 12" 1 8" 12" 1 14" 16" 16" 30" 14" 22" 1 18" 14" 16" 1 10" 1 14" 1 10" 1 14" 1 16" 1 18" 18" 1 34" 16" 26" 1 20" 16" 18" 1 12" 1 16" 1 12" 1 16" 1 18" 1 20" 20" 1 36" TYPICAL THRUST BLOCK DETAIL W NO SCALE A S-0" SPIDERS SUPPORT CARRIER PIPE IN CASING ENCLOS ENDS WITH B" BRICK MASONRY �2" BEVEL UNE CARRIER PIPE BOLTS CARRIER PIPE (SPIDER SIZE DETEW SIZE OF STEEL CASK INNER PIPE.) STEEL CASING PIPE J WFSLOPE TO DRAIN 2" WEEP HOLE DUTY SKIDS (4) SECTION "A" vTr.1� a ig TYPICAL BORING & JACKING DETAILKW NO SCALE 8 nLE IRONN Q F d a 12" 12" w 'I /SAW CUT IXIST. PAVEMENT N av EXIT. ` IXIST. PAVi. Op OQapp°gip R�p°p OOpp°o pppOQ r 10" STONE MEETING N.C.D.O.T. SPECIFICATIONS °oa°oao°oo°° opoQao p0°°Op i COMPACTED T00100 % MAXIMUM DRY DENSITY ( o I NOTES: 1. PAVEMENT SHALL BE CUT TO TRUE LINE AND REMOVED BEFORE TRENCH IS CUT. 2. STONE AND PAVEMENT TO BE PLACED WITH LEAST INTERFERENCE TO TRAFFIC. NEW COMPACTED BACKFILL 3. STABILIZED AGGREGATE TO BE SECURED FROM AN PIPE APPROVED QUARRY. ( 4. ALL PAVEMENT REPAIRS TO BE IN ACCORDANCE WITH N.C.D.O.T. SPECIFICATIONS. PIPE O.D. PLUS 18" FOR PIPES UNDER 33" O.D. PIPE O.D. PLUS 24" FOR PIPES OVER 33" O.D. TYPICAL TRENCH IN BITUMINOUS SURFACE AREAS DETAIL NO SCALE NOTES: 1. INSTALL METER AT R/W 2. "TWO (2)-3/4" SERVICE LINES MUST BE INSTALLED INSIDE A 2 SLEEVE. r 3. (2)-1" SERVICE LINES MUST BE INSTALLED I"TWO INSIDE A 3" SLEEVE.' w w 4. SLEEVES SHOULD BE SCHEDULE 40 PVC PIPE. EL z 5. SEE DETAIL FOR SERVICE MATERIAL AND METER 0 J SETTING a 6. SERVICE LINE SHALL BE 3' BELOW FINISHED GRADE OF DITCHES. 7. CONDUIT MUST EXTEND PAST PREPOSED SIDEWALK. 1' R/W SIDEWALK 2" PVC SLEEVE W/ 3/4" CARRIER 1� SINGLE 3/4" SERVICES METERS SHOULD BE,/} F_ INSTALLED 3' OFF w w PROPERTY LINE a J 0 CY a TYPICAL DOMESTIC WATER SERVICE INSTALLATION DETAIL NO SCALE EXISTING AS NOTED ON PLANS ROAD � ROAD SHOULDER z BACKFILL AS INDICATED z• II N� M� 1� 45' BEND NEW WATER LINE SERVICE LINE TO CORPORATION METER CONNECTION COCK—A.Y. MCDONALD OR EQUAL SERVICE SADDLE — A.Y. MCDONALD OR EQUAL STYLE HINGED 3891 FOR 3/4' SERVICE SADDLE — A.Y. MCDONALD OR EQUAL TRENCH WIDTH PIPE O.D. + 18I " FOR PIPES UNDER 33" O.D. NOTE: PPE O.D. + 24 FOR PPES OVER 33" O.D. 1. "SERVICE CONNECTION" IN PROPOSAL TO INCLUDE SERVICE SADDLE, 45- BEND, CORPORATION COCK AND ALL LABOR INVOLVED IN MAKING A COMPLETE SERVICE CONNECTION. 2. SERVICE PIPING TO BE 3/4" SDR-9 PE TUBING 3. ALL BRASS FITTINGS SHALL BE COMPRESSION TYPE TYPICAL WATER SERVICE CONNECTION USING TAPPING SADDLE DETAIL W NO SCALE 1 3 LAYI N G CONDITIONS DESCRIPTION O PIPE BEDDED IN MININUM JOB EXCAVATED MATERIAL. BACKFILL LIGHTLY CONSOLIDATED TO TOP OF PIPE. TYPE 3 PIPE BEDDED IN SAND, GRANULAR MATERIAL OR GRADED GRAVEL TO THE DEPTH OF 1/8 PIPE DIAMETER, 4" MIN. JOB EXCAVATED MATERIAL COMPACTED TO 4" ABOVE TOP OF PIPE. (APPROX. 95% STANDARD PROCTOR, AASHTO T-99) TYPE 4 TYPICAL LAYING CONDITIONS DETAIL W NO SCALE 1 1 PROJECT USE ALL DUCTILE IRON GRAVITY SEWER LINE. ALL PVC WATER LINE AND PVC FORCE MAIN. Of 1' FROM EDGE OF ROW a 0 o_ METER BOX LID, CAST IRON w 9 0 U 3/4 Inch Go to Volve Z R,q,u,d o� Cato__ ,de 3 X 18° With 12 ���ne� 01 SERVICE LINE B SS NIPPLE me Mete: eox FROM STREET A. METER SETTER CENTERED IN BOX METER -0 BE INSTALLED \IRV L,c,t,,, down 1 the c,t—o11 valve BRICK SUPPORT METER SETTER WITH DOUBLE CHECK VALVE 1. METER AND PRIVATE SERVICE LINE NOT IN CONTRACT UNLESS SPECIFIED (BACKFLOW PREVENTER) 2. INCLUDE STONE IN PRICE OF METER BOX. 3. METER SETTER SIZE AS NOTED ON PLANS. 4. ALL BRASS FITTINGS SHALL BE COMPRESSION TYPE. TYPICAL 3/4" METER SETTER INSTALLATION DETAIL NO SCALE 4 V PLAN 18 ELEVATION AO a 24"x 18" R—TA K-1 ii AD V/ ISOMETRIC 24 18" IRON + + + + + + + + + + + + + + + 11" + + + + + + +M�T�R + + ++ ++ + ++ + + + + + + + + + + 16 3/4" TYPICAL METER BOX DETAIL FOR 3/4" SERVICE NO SCALE 9/04/2019 !,5,p •.-f a� . SEAL 16941 ,fir e9�Ae ••.•• G 1 is � ••��r` C1 rW V rw^� LO rz w q4°a I O W � V CO C\2 w E rEll%llui r� V O H O V ) Ines Q �1 a C n U w W Q C~ o c1 MMw� O M v E-1 O H U w m W O 0_ K U W O I O 2 DATE: 04.01.17 SCALE: 1 "=80' DESIGNED:: SWB CHECKED. SWB DRAWN: SWJ APPROVED: IDG LLC SHEET: 7 7 of CAD FILE: CAMERON PROJECT NO: 2019.02