Loading...
HomeMy WebLinkAboutSW6100701_Add Info_20100827Av,n NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor Mr. Joe E. Godwin, Sr., PE Enoch Engineers, PA 1403 NC 50 S. Benson, NC 27504 Dear Mr. Godwin: Division of Water Quality Colee6 H. Sullins Director August 27, 2010 DENR-FRO ,IUN 16 2011 DENR--FRC AUG 3 '1 20 ttJWO Subject: Request for Additional Information Stormwater Project No. SW6100701 Traemoor Connection Cumberland County Dee Freeman Secretary The Division of Water Quality Central Office received a Stormwater Management Permit Application for the subject project on'uly 2, 2010, and additional information received August 13 & 19,.2010. A preliminary review Q.Ubat information has.determined that the application is still not complete. The following information is needed to continue the stormwater review: Review of items from the Jul 12r2010 additional information request: 1. The'deed'festriction forr n vvas submitted, but it is not completed correctly. Each outparcel needs to be'id'ert1fied with -its allot?ed BUA listed. 2. The soils report provided states that the SHWT is 2.5 feet above the PPE of the pond. This can lead to the groundwater taking up all or part of the storage volume that is supposed to be available for stormwater runoff. Please provide needed information to prove that there is enough available storage volume. Information on what needs to be provided is in 10.3.2 of the BMP Manual. 3. The drainage area provided does not appear to be correct. It is not shown following the contours correctly from around the outlet of the pond south to the duplex area around the southeast corner of the property. It appears that some of the duplexes do not drain to the pond, but drain east off of the site. Please also -provide contour labels. It is very difficult to determine what elevations are for unlabeled ccz tours that do not intersect with the existing contours, which are labeled. 4. The HT and'Iharmacy sites should be included in the deed restrictions with allotted BUAs. 5. Item resolved. . 6. Item has been pair ially addressed with site plan of parts of the site shown on S-4a. Any change to or detail finalized -site plans must.be submitted for approval by DWQ. 7. Item addressed. 8. Item has been partially addressed. There is still not sufficient detail shown or information provided that shows that all the proposed BUA will be captured and treated by the pond. Locations of roof drains or notes stating that they must be directed to the pond must be provided. 9. This item still needs to be addressed. I n Wetlands and Stormwater Branch 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX: 919-807-64941 Customer Service: 1.877-623-6748 Internet: www,ncwaterquality.org An Equal Opportunity 1 Affirmalive Action Employer L?= k�b L�3'U V l5 MAY 0 A Z011' No rtliCarolina NR - WATER 60 Nil turally etlendta & 3inanwataC Bnwwh Mr. Joe E. Godwin. Sr., PE SW6100701 — Traemoor Connection August 27, 2010 10. This item still needs to be addressed. 11. Item resolved. 12. Item submitted. 13. Item resolved. 14. Item resolved. 15. Item resolved. 16. Item resolved. 17. This item still needs to' be addressed. 18. This i.ent still needs to, be addressed. 19. Ilem resolved. 20. I1em resolved. 21. Item resole ere. 22. Item resolved. 23. Item res',)1ved. 24. This item still needs to be addressed. Additional items that need to be addressed: l . The revised plans submitted are not sealed, signed, and dated. Also, 2 copies of revised plans must be provided. All plans and calculations submitted must be sealed, signed, and dated; and include a revision date. Please note that this requc!:t for additio,:al information is in response to a preliminary review. The requested information should be received by this Office prior to September 27, 2010, or the application will be returned as incSr:j)lete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need add:!b.onal time to submit the information, please mail, fax, or email your request for a time extension to the:Division at the address and fax number at the bottom of this letter. The request must indicate the date try which'you.expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is'a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. Please reference the State assigned project number SW6100701 on all correspondence. If you have any questions concerning this matter please feel free to contact me at (919) 807-6375, or robert.patterson@ncdenr.gov. Sincerely, Robert D. Patterson, PE Environmental Engineer Stormwater Permitting Unit cc: Jackie Hairr — HCG INVESTM ENTS,- LE ,S Fayetteville Regional Office — Mike; Lawyer DWQ Central Files , s SW6100701 File ?:'� "W 2 of 2