HomeMy WebLinkAboutNCG030706_2022 DMR_20221007 NCDEQ Division of Energy,Mineral and Land Resources
St,-:,rmwater Discharge Monitoring Report(DMR) Form for NCG030000
Metal Fabrication
Click here for instructions
Complete,sign,scan and submit the DMR via the Stormwater NPOES Permit Data Monitoring Report(DMR)Upload form within
30 days of receiving sam piing results. Mail the original,signed hard copy of the DMR to the appropriate DEMLR Regional Office.
Certificate of Coverage No. NCGO3 0706 Person Collecting Samples: Michael Kilpatrick
Facility Name:Greenheck Fan Corporation-TAP Laboratory Name: Pace Analytical Services
Facility County: Cleveland Laboratory Cert. No.: 329
Discharge during this period-fl Yes ❑No (if no,skip to signature and date)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances?QYes 0 No
If so,which Tier(I,II,or III)? Tier I -Zinc
A copy of this DMR has been uploaded electronically via https://edocs.deq.nc,gov/Forms/SW-DMR Ekes ®No
Date Uploaded:
Analytical Monitoring Requirements for Outfalls with Industrial Activities—Benchmarks in(Red)
Parameter Parameter Outfall 002 Outfall 003 Outfall Outfall Outfall
Code
N/A Receiving Stream Class Class C Class C
N/A Date Sample Collected MM/DD/YYYY 9/10/2022 9/10/2022
II
46529 24-Hour Rainfall in inches 0.64 0.64
C0530 TSS in mg/L 00 or 50') <2.5 5.9
00400 pH in standard units(6.0-9.0 FW, 6.2 6.3
6.8-8.5 SW)
01119 Copper,totai recoverable in mg/L 0.0045 <0.0020
(0.010 FW,0 �5o Sidi
01051 Lead,total recoverable in mg/L <0.0020 <0.0020
(0.075FW,01.:SW)
01094 Zinc,total recoverable in mg/L(0.126 0.220 0.048
FW,0.095 51°.!)
00340 Chemical Oxygen Demand(COD)in <20 <20
mg/L(120)
00552 Non-Polar Oil&Grease in mg/L(15) <5.1 <5.1
* Outfalls to Outstanding Resource Waters(ORW),High Quality Waters(HQW),Trout Waters(Tr)and Primary Nursery Areas(PNA)
have a benchmark TSS limit of 5:r mg/L.All other water classifications have a benchmark of 100 mg/L
(Freshwater)Sw(Saltwater)
Notes(optional): Outfall 002 was inspected for sources of contamination and public road run-off due containing construction materials may be the source.
"I certify by my signature below,under penalty of law,that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted.Based on my
inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information,the information
submitted is,to the best of my knowledge and belief,true,accurate,and complete.I am aware that there are significant penalties for submitting
false information,includingthe possibility of fines and imprisonment for knowing violations."
11(I ..,......(
l Q -7- ZZ
Signature of Permittee oar Delegated Authorized Individual Date
derek.boyd@greenhec c.com 715.841.8366
Email Address Phone Number