Loading...
HomeMy WebLinkAboutSW3191204_Plan (Set)_20200106PLAN REFERENCES AND CONTACTS REFERENCES 3Oill]019LlW-ra-4Ito] Ii1e3:L1W:116 SURVEY: BOHLER ENGINEERING "BOUNDARY AND TOPOGRAPHIC SURVEY FOR SAVS GROUP" CONTACT:CARY WATTS 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 DATED: 11 /14/ 19 PHONE: 980-272-3400 ♦GEOTECHNICAL INVESTIGATION REPORT: CESI CONTACT: JAMES G. EAVES III 45 SPRING STREET, SW P.O.BOX 268 CONCORD, NC 28026-0268 DATED: 11 /14/2019 PHONE: 704-786-5404 *ARCHITECTURAL PLAN: PROGRESS DESIGN STUDIO CONTACT: MICHAEL HAYNES 5403 DITCHLEY ROAD RICHMOND, VA 23226 PHONE: (704) 692-9587 GOVERNING AGENCIES *UNION COUNT PLANNING & ZONING CONTACT: RICHARD BLACK - DIVISION DIRECTOR, PLANNING 500 N. MAIN ST. STE 70 MONROE, NC 28112 PHONE: (704) 292-2580 EMAIL: rblack@unioncountync.gov *NORTH CAROLINA DEPARTMENT OF TRANSPORTATION (NCDOT) DISTRICT 3 CONTACT: LEE AINSWORTH,III, PE 130 S. SUTHERLAND AVE MONROE, NC 28112 _ PHONE: (704) 218^6100 r^r ♦WATER/SANITARY SEWER UNION COUNTY PUBLIC WORKS ENGINEERING DEPARTMENT SOON. MAIN STREET CHARLOTTE, NC 28112 PHONE: (704) 296-4210 DEPARTMENT COMPANY NAME CONTACT: JOHNNY BLYTHE - FIRE CONTACT - POSITION CHIEF ADDRESS 6628 MILLGROVE RD. INDIAN TRAIL, NC 28079 CITY, STATE XXXXX PHONE: (704) 882-2100 PHONE: (XXX) XXX-XXXX ♦ N C D E Q FAX: (XXX) XXX-XXXX CONTACT: ZAHID KHAN - ENGINEERING SUPERVISOR *GAS 610 EAST CENTER AVENUE - STE 301 MOORESVILLE, NC 28155 COMPANY NAME PHONE: (704) 663-1699 CONTACT - POSITION UTILITIES ADDRESS *ELECTRIC CITY, STATE XXXXX CONTACT: KEITH HELMS PHONE: (XXX) XXX-XXXX UNION POWER CORPORATIVE FAX: (XXX) XXX-XXXX P.M. BOX 5014 MONROE, NC 28110 PHONE: (704) 289-3145 THE ABOVE REFERENCED DOCUMENTS ARE INCORPORATED BY REFERENCE AS PART OF THESE PLANS, HOWEVER, BOHLER ENGINEERING DOES NOT CERTIFY THE ACCURACY OF THE WORK REFERENCED OR DERIVED FROM THESE DOCUMENTS, BY OTHERS. GENERAL NOTE: IT IS THE RESPONSIBILITY OF THE CONTRACTORTO REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THIS PROJECT VORK SCOPE PRIORTO THE INITIATION OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND A CONFLICT WITH THE DOCUMENTS RELATIVE T THE SPECIFICATIONS OR APPLICABLE CODES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFYTHE PROJECT ENGINEER OF RECORD IN WRITING PRIORTO THE START OF CONSTRUCTION. FAILURE BYTHE CONTRACTORTO NOTIFY THE PROJECT ENGINEER SHALL CONSTITUTE kCCEPTANCE OF FULL RESPONSIBILITY BYTHE CONTRACTORTO COMPLETE THE SCOPE OF THE WORKAS DEFINED BY THE DRAWINGS AND I FULL CONFORMANCE WITH LOCAL REGULATIONS AND CODES. A.R..KA 1 IEI..(- .R..KA I 1�1 ­1 Ss A LOCATION OF SITE ace 4610 OLD CHARLOTTE HIGHWAY, MONROE TOWNSHIP 9 al PARCEL NO. 09366020 UNION COUNTY, NORTH CAROLINA Q1 S T W n H ir°w l ��\ 49 'Ppoose Greek 51 � Matthews 51A 5 j 52� �` p. Hem_y Bridge 5 Lake PaFk— s Po .IndianTrail SR 1362 Ra F.... t SITE o � G t woad _ B k \ r- \ :\ 7� I D% 00 A 11 k. .,Rme Re CI bvle A \\ l Crestview Acre �r Fox Run S "�\ Kimberly Courts SR Hillsdale h 84 Berit He Shts N Monroe Sh cad F t 8< 1 LOCATION MAP DELORME STREET ATLAS 2004 PLUS USA SCALE: N.T.S. OWNER/DEVELOPER BARNETTE STORE, LLC 231 POST OFFICE DRIVE, SUITE B-8 INDIAN TRAIL, NC 28079 PREPARED BY TM 000���� V ESV In deS�Jil��IIIn ll��JAS�II �Ld NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@BohlerEng.com CONTACT: STEVE FARMARTINO Sheet List Table Sheet Number Sheet Title C-101 Cover Sheet C-102 General Notes C-103 General Notes C-104 Survey C-201 Existing Conditions & Demolition Plan C-301 Site Plan C-302 Site Details C-401 Overall Grading Plan C-402 Stormwater Details C-403 Pond Details C-404 Pond Details C-501 Overall Utility Plan C-502 Utility Plan C-503 Utility Details C-504 Utility Details C-505 Utility Details C-601 E&SC Plan Phase I C-602 E&SC Plan Phase II C-604 Erosion and sediment details C-605 Erosion and sediment details C-606 Erosion and sediment details C-607 Erosion and sediment details C-701 Landscape Plan C-702 Wet Pond Planting Plan C-703 Mitigation Plan C-704 Landscaping Details C-801 Striping and Signage Plan C-802 Pavement Plan C-803 Sight Distance Profile C-804 Sight Distance Profile C-805 Arka Heights Cross Sections C-806 Arka Heights Cross Sections C-807 NCDOT Details C-808 NCDOT Details ISSUED FOR CONSTRUCTION SIGNATURE DATE SIGNATURE DATE SIGNATURE DATE THIS DOCUMENT IS NOT ISSUED BY BOHLER ENGINEERING FOR CONSTRUCTION WITHOUT (3) SIGNATURES PROJECT # REVISION DATE: LTJ a Pq (^1 ® U 6 IN REVISIONS REV DATE COMMENT BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: CAD I.D.: NCC182110SD0 rPROJECT ARKA HEIGHTS FOR A]E KA HEIGHTS, LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY r TO) 0 0 La TLTEHR�. ENGHM EIERING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)30hierEng.com rSHEET TITLE: COVERSHEET SHEET NUMBER: C - 10 1 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211OSDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:54 PM LAST SAVED BY: MMOORE GaEN ERAL NOTES (Rev. 1 /2019) 1. THESE PLANS ARE SOLELY BASED ON INFORMATION THE OWNER AND OTHERS PROVIDED TO BOHLER ENGINEERING NC, PLLC (HEREIN "BOHLER ENGINEERING") PRIOR TO THE DATE ON WHICH ENGINEER PREPARED THESE PLANS. THE CONTRACTOR MUST FIELD VERIFY ALL EXISTING CONDITIONS AND IMMEDIATELY NOTIFY BOHLER ENGINEERING, IN WRITING, IF ANY ACTUAL SITE CONDITIONS DIFFER FROM THOSE SHOWN ON THESE PLANS, OR IF THE PROPOSED WORK CONFLICTS WITH ANY OTHER SITE FEATURES. 2. THE CONTRACTOR MUST STRICTLY COMPLY WITH THESE NOTES AND ALL SPECIFICATIONS/REPORTS CONTAINED HEREIN. THE CONTRACTOR MUST ENSURE THAT ALL SUBCONTRACTORS FULLY AND COMPLETELY CONFORM TO AND COMPLY WITH THESE REQUIREMENTS THESE NOTES AND THE REQUIREMENTS ARTICULATED IN THE NOTES CONTAINED IN ALL THE OTHER DRAWINGS THAT COMPRISE THE PLAN SET OF DRAWINGS. ADDITIONAL NOTES AND SPECIFIC PLAN NOTES MAY BE FOUND ON THE INDIVIDUAL PLANS. THESE GENERAL NOTES APPLY TO THIS ENTIRE DOCUMENT PACKAGE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL CONSTRUCTION CONTRACT DOCUMENTS INCLUDING BUT NOT LIMITED TO ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THE PROJECT WORK SCOPE, PRIOR TO THE INITIATION AND COMMENCEMENT OF CONSTRUCTION. 3. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST CONFIRM WITH THE ENGINEER OF RECORD THAT THE LATEST EDITION OF THE DOCUMENTS AND/OR REPORTS REFERENCED WITHIN THE PLAN REFERENCES ARE BEING USED FOR CONSTRUCTION. THIS IS THE CONTRACTOR'S SOLE AND COMPLETE RESPONSIBILITY. 4. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION THE CONTRACTOR MUST ENSURE THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEEN OBTAINED. NO CONSTRUCTION OR FABRICATION IS TO BEGIN UNTIL THE CONTRACTOR HAS RECEIVED AND THOROUGHLY REVIEWED THE CONDITIONS OF APPROVAL TO ALL PLANS AND OTHER DOCUMENTS REVIEWED AND APPROVED BY THE PERMITTING AUTHORITIES AND HAS ALSO CONFIRMED THAT ALL NECESSARY AND REQUIRED PERMITS HAVE BEEN OBTAINED. THE CONTRACTOR MUST HAVE COPIES OF ALL PERMITS AND APPROVALS ON SITE AT ALL TIMES. 5. THE CONTRACTOR MUST ENSURE THAT ALL WORK IS PERFORMED IN ACCORDANCE WITH THESE PLANS SPECIFICATIONS/REPORTS AND CONDITIONS OF APPROVAL AND ALL APPLICABLE REQUIREMENTS RULES REGULATIONS STATUTORY REQUIREMENTS CODES LAWS AND STANDARDS OF ALL GOVERNMENTAL ENTITIES WITH JURISDICTION OVER THIS PROJECT, AND ALL PROVISIONS IN AND CONDITIONS OF THE CONSTRUCTION CONTRACT WITH THE OWNER/DEVELOPER INCLUDING ALL EXHIBITS, ATTACHMENTS AND ADDENDA TO SAME. 6. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR MUST COORDINATE THE BUILDING LAYOUT BY CAREFULLY REVIEWING THE MOST CURRENT ARCHITECTURAL, CIVIL AND STRUCTURAL CONSTRUCTION DOCUMENTS (INCLUDING, BUT NOT LIMITED TO, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION PLANS,[] WHERE APPLICABLE). THE CONTRACTOR MUST IMMEDIATELY NOTIFY OWNER, ARCHITECT AND ENGINEER OF RECORD, IN WRITING, OF ANY CONFLICTS, DISCREPANCIES OR AMBIGUITIES WHICH EXIST BETWEEN THESE PLANS AND ANY OTHER PLANS THAT COMPRISE THE CONSTRUCTION DOCUMENTS. 7. CONTRACTOR MUST REFER TO AND ENSURE COMPLIANCE WITH THE APPROVED ARCHITECTURAL/BUILDING PLANS OF RECORD FOR EXACT LOCATIONS AND DIMENSIONS OF ENTRY/EXIT POINTS, ELEVATIONS, PRECISE BUILDING DIMENSIONS, AND EXACT BUILDING UTILITY LOCATIONS. 8. THE CONTRACTOR MUST FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS SHOWN ON THESE PLANS, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. THE CONTRACTOR MUST IMMEDIATELY NOTIFY ENGINEER OF RECORD, IN WRITING, IF ANY CONFLICTS, DISCREPANCIES, OR AMBIGUITIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION. NO EXTRA COMPENSATION WILL BE PAID TO THE CONTRACTOR FOR WORK WHICH HAS TO BE RE -DONE OR REPAIRED DUE TO DIMENSIONS, MEASUREMENTS OR GRADES SHOWN INCORRECTLY ON THESE PLANS PRIOR TO BOTH (A) THE CONTRACTOR GIVING ENGINEER OF RECORD WRITTEN NOTIFICATION OF SAME AND (B) ENGINEER OF RECORD, THEREAFTER, PROVIDING THE CONTRACTOR WITH WRITTEN AUTHORIZATION TO PROCEED WITH SUCH ADDITIONAL WORK. 9. THE CONTRACTOR MUST VERIFY ALL DIMENSIONS AND MEASUREMENTS INCLUDED ON DESIGN DOCUMENTS HEREIN AND MUST NOT SCALE OFF THE DRAWINGS DUE TO POTENTIAL PRINTING INACCURACIES. ALL DIMENSIONS AND MEASUREMENTS ARE TO BE CHECKED AND CONFIRMED BY THE GENERAL CONTRACTOR PRIOR TO PREPARATION OF SHOP DRAWINGS, FABRICATION/ORDERING OF PARTS AND MATERIALS AND COMMENCEMENT OF SITE WORK. SITE PLAN DRAWINGS ARE NOT INTENDED AS SURVEY DOCUMENTS. DIMENSIONS SUPERSEDE GRAPHICAL REPRESENTATIONS. THE CONTRACTOR MUST MAKE CONTRACTOR'S OWN MEASUREMENTS FOR LAYOUT OF IMPROVEMENTS. 10. THE OWNER AND CONTRACTOR MUST BE FAMILIAR WITH, AND RESPONSIBLE FOR THE PROCUREMENT OF ANY AND ALL CERTIFICATIONS REQUIRED FOR THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 11. WHEN INCLUDED AS ONE OF THE REFERENCED DOCUMENTS, THE GEOTECHNICAL REPORT, SPECIFICATIONS AND RECOMMENDATIONS SET FORTH THEREIN ARE A PART OF THE REQUIRED CONSTRUCTION DOCUMENTS AND, IN CASE OF CONFLICT, DISCREPANCY OR AMBIGUITY, THE MORE STRINGENT REQUIREMENTS AND/OR RECOMMENDATIONS CONTAINED IN: (A) THE PLANS; AND (B) THE GEOTECHNICAL REPORT AND RECOMMENDATIONS, MUST TAKE PRECEDENCE UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLANS. THE CONTRACTOR MUST NOTIFY THE ENGINEER OF RECORD, IN WRITING, OF ANY SUCH CONFLICT, DISCREPANCY OR AMBIGUITY BETWEEN THE GEOTECHNICAL REPORT AND PLANS AND SPECIFICATIONS, PRIOR TO PROCEEDING WITH ANY FURTHER WORK.[] IF A GEOTECHNICAL REPORT WAS NOT CREATED, THEN THE CONTRACTOR MUST FOLLOW AND COMPLY WITH ALL OF THE REQUIREMENTS OF ANY AND ALL MUNICIPAL, COUNTY, STATE, AND FEDERAL LAWS AND APPLICABLE SPECIFICATIONS WHICH HAVE JURISDICTION OVER THIS PROJECT. 12. ENGINEER OF RECORD IS NEITHER LIABLE NOR RESPONSIBLE FOR ANY SUBSURFACE CONDITIONS AND FURTHER, HAS NO LIABILITY FOR ANY HAZARDOUS MATERIALS, HAZARDOUS SUBSTANCES, OR POLLUTANTS ON, ABOUT OR UNDER THE PROPERTY. 13. THE CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING WHEN AND WHERE SHORING IS REQUIRED AND FOR INSTALLING ALL SHORING REQUIRED DURING EXCAVATION (TO BE PERFORMED IN ACCORDANCE WITH CURRENT OSHA STANDARDS) AND ANY ADDITIONAL PRECAUTIONS TO BE TAKEN TO ASSURE THE STABILITY OF ADJACENT, NEARBY AND CONTIGUOUS STRUCTURES AND PROPERTIES. ALL OF THIS WORK IS TO BE PERFORMED AT CONTRACTOR'S SOLE COST AND EXPENSE. 14. THE CONTRACTOR MUST EXERCISE EXTREME CAUTION WHEN PERFORMING ANY WORK ACTIVITIES ADJACENT TO PAVEMENT, STRUCTURES, ETC. WHICH ARE TO REMAIN EITHER FOR AN INITIAL PHASE OF THE PROJECT OR AS PART OF THE FINAL CONDITION. THE CONTRACTOR IS RESPONSIBLE FOR TAKING ALL APPROPRIATE MEASURES REQUIRED TO ENSURE THE STRUCTURAL STABILITY OF SIDEWALKS AND PAVEMENT, UTILITIES, BUILDINGS, AND INFRASTRUCTURE WHICH ARE TO REMAIN, AND TO PROVIDE A SAFE WORK AREA FOR THIRD PARTIES, PEDESTRIANS AND ANYONE INVOLVED WITH THE PROJECT. 15. DEBRIS MUST NOT BE BURIED ON THE SUBJECT SITE. ALL DEMOLITION AND CONSTRUCTION WASTES, UNSUITABLE EXCAVATED MATERIAL, EXCESS SOIL AND DEBRIS (SOLID WASTE) MUST BE DISPOSED OF IN ACCORDANCE WITH THE REQUIREMENTS OF ANY AND ALL MUNICIPAL, COUNTY, STATE, AND FEDERAL LAWS AND APPLICABLE CODES WHICH HAVE JURISDICTION OVER THIS PROJECT OR OVER THE CONTRACTOR. 16. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO MAINTAIN RECORDS TO DEMONSTRATE PROPER AND FULLY COMPLIANT DISPOSAL ACTIVITIES, TO BE PROMPTLY PROVIDED TO THE OWNER UPON REQUEST. 17. THE CONTRACTOR MUST REPAIR, AT CONTRACTOR'S SOLE COST, ALL DAMAGE DONE TO ANY NEW OR EXISTING CONSTRUCTION OR PROPERTY DURING THE COURSE OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO DRAINAGE, UTILITIES, PAVEMENT, STRIPING, CURB, ETC. AND MUST BEAR ALL COSTS ASSOCIATED WITH SAME TO INCLUDE, BUT NOT BE LIMITED TO, REDESIGN, RE -SURVEY, RE -PERMITTING AND CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR AND MUST REPLACE ALL SIGNAL INTERCONNECTION CABLE, WIRING CONDUITS, AND ANY UNDERGROUND ACCESSORY EQUIPMENT DAMAGED DURING CONSTRUCTION AND MUST BEAR ALL COSTS ASSOCIATED WITH SAME. THE REPAIR OF ANY SUCH NEW OR EXISTING CONSTRUCTION OR PROPERTY MUST RESTORE SUCH CONSTRUCTION OR PROPERTY TO A CONDITION EQUIVALENT TO OR BETTER THAN THE CONDITIONS PRIOR TO COMMENCEMENT OF THE CONSTRUCTION, AND IN CONFORMANCE WITH APPLICABLE CODES, LAWS, RULES, REGULATIONS, STATUTORY REQUIREMENTS AND STATUTES. THE CONTRACTOR MUST BEAR ALL COSTS ASSOCIATED WITH SAME. THE CONTRACTOR MUST, PROMPTLY, DOCUMENT ALL EXISTING DAMAGE AND NOTIFY, IN WRITING, THE OWNER AND THE CONSTRUCTION MANAGER PRIOR TO THE START OF CONSTRUCTION. 18. THE ENGINEER OF RECORD AND BOHLER ENGINEERING ARE NOT RESPONSIBLE FOR AND HAVE NO CONTRACTUAL, LEGAL OR OTHER RESPONSIBILITIES FOR JOB SITE SAFETY JOB SITE SUPERVISION, OR ANYTHING RELATED TO SAME. THE ENGINEER OF RECORD AND BOHLER ENGINEERING HAVE NOT BEEN RETAINED TO PERFORM OR TO BE RESPONSIBLE FOR JOB SITE SAFETY, SAME BEING WHOLLY OUTSIDE OF ENGINEER OF RECORD'S AND BOHLER ENGINEERING SERVICES AS RELATED TO THE PROJECT. THE ENGINEER OF RECORD AND BOHLER ENGINEERING ARE NOT RESPONSIBLE TO IDENTIFY OR REPORT ANY JOB SITE SAFETY ISSUES OR ANY JOB SITE CONDITIONS, AT ANY TIME. 19. THE CONTRACTOR MUST IMMEDIATELY IDENTIFY IN WRITING, TO THE ENGINEER OF RECORD AND BOHLER ENGINEERING, ANY DISCREPANCIES THAT MAY OR COULD AFFECT THE PUBLIC SAFETY, HEALTH OR GENERAL WELFARE, OR PROJECT COST. IF THE CONTRACTOR PROCEEDS WITH CONSTRUCTION WITHOUT PROVIDING PROPER WRITTEN NOTIFICATION AS DESCRIBED ABOVE, IT WILL BE AT THE CONTRACTOR'S OWN RISKAND, FURTHER, THE CONTRACTOR MUST INDEMNIFY, DEFEND AND HOLD HARMLESS THE ENGINEER OF RECORD AND BOHLER ENGINEERING FOR ANY AND ALL DAMAGES, COSTS, INJURIES, ATTORNEY'S FEES AND THE LIKE WHICH RESULT FROM OR ARE IN ANY WAY RELATED TO SAME INCLUDING, BUT NOT LIMITED TO, ANY THIRD PARTY AND FIRST PARTY CLAIMS. 20. THE ENGINEER OF RECORD AND BOHLER ENGINEERING ARE NOT RESPONSIBLE FOR ANY INJURY OR DAMAGES RESULTING FROM THE CONTRACTOR'S FAILURE TO BUILD OR CONSTRUCT IN STRICT ACCORDANCE WITH THE APPROVED PLANS, AND CURRENT CODES, RULES, STATUTES AND THE LIKE. IF THE CONTRACTOR AND/OR OWNER FAIL TO BUILD OR CONSTRUCT IN STRICT ACCORDANCE WITH APPROVED PLANS, RULES, STATUTES, CODES AND THE LIKE, THE CONTRACTOR AND/OR OWNER AGREE TO AND MUST JOINTLY, INDEPENDENTLY, SEPARATELY, AND SEVERALLY INDEMNIFY AND HOLD THE ENGINEER OF RECORD AND BOHLER ENGINEERING HARMLESS FOR AND FROM ALL INJURIES, CLAIMS AND DAMAGES THAT ENGINEER AND BOHLER ENGINEERING SUFFER AND ANY AND ALL COSTS THAT ENGINEER AND BOHLER ENGINEERING INCUR AS RELATED TO SAME. 21. ALL CONTRACTORS MUST CARRY AT LEAST THE MINIMUM AMOUNT OF THE SPECIFIED AND COMMERCIALLY REASONABLE STATUTORY WORKER'S COMPENSATION INSURANCE, EMPLOYER'S LIABILITY INSURANCE AND COMMERCIAL GENERAL LIABILITY INSURANCE (CGL) INCLUDING ALSO ALL UMBRELLA COVERAGES. ALL CONTRACTORS MUST HAVE THEIR CGL POLICIES ENDORSED TO NAME BOHLER ENGINEERING, AND ITS PAST, PRESENT AND FUTURE OWNERS, OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS, SERVANTS, EMPLOYEES, AFFILIATES, SUBSIDIARIES, AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS AS ADDITIONAL NAMED INSUREDS AND TO PROVIDE CONTRACTUAL LIABILITY COVERAGE SUFFICIENT TO INSURE THE (DEFEND, IF APPLICABLE) AND HOLD HARMLESS AND INDEMNITY OBLIGATIONS ASSUMED AND AGREED TO BY THE CONTRACTOR HEREIN. ALL CONTRACTORS MUST FURNISH BOHLER ENGINEERING WITH CERTIFICATIONS OF INSURANCE OR CERTIFICATES OF INSURANCE AS EVIDENCE OF THE REQUIRED INSURANCE COVERAGES PRIOR TO COMMENCING ANY WORK AND UPON RENEWAL OF EACH POLICY DURING THE ENTIRE PERIOD OF CONSTRUCTION AND FOR TWO YEARS AFTER THE COMPLETION OF CONSTRUCTION AND AFTER ALL PERMITS ARE ISSUED, WHICHEVER DATE IS LATER. IN ADDITION, ALL CONTRACTORS AGREE THAT THEY WILL, TO THE FULLEST EXTENT PERMITTED UNDER THE LAW, INDEMNIFY, DEFEND AND HOLD HARMLESS BOHLER ENGINEERING AND ITS PAST, PRESENT AND FUTURE OWNERS, OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS, AGENTS, SERVANTS, EMPLOYEES, AFFILIATES, SUBSIDIARIES, AND RELATED ENTITIES, AND ITS SUBCONTRACTORS AND SUBCONSULTANTS FROM AND AGAINST ANY DAMAGES, INJURIES, CLAIMS, ACTIONS, PENALTIES, EXPENSES, PUNITIVE DAMAGES, TORT DAMAGES, STATUTORY CLAIMS, STATUTORY CAUSES OF ACTION, LOSSES, CAUSES OF ACTION, LIABILITIES OR COSTS, INCLUDING, BUT NOT LIMITED TO, REASONABLE ATTORNEYS' FEES AND DEFENSE COSTS, ARISING OUT OF OR IN ANY WAY CONNECTED WITH OR TO THE PROJECT, INCLUDING ALL CLAIMS BY EMPLOYEES OF THE CONTRACTOR(S), ALL CLAIMS BY THIRD PARTIES AND ALL CLAIMS RELATED TO THE PROJECT. THE CONTRACTOR MUST NOTIFY ENGINEER, IN WRITING, AT LEAST THIRTY (30) DAYS PRIOR TO ANY TERMINATION, SUSPENSION OR CHANGE OF ITS INSURANCE HEREUNDER. 22. THE ENGINEER OF RECORD AND BOHLER ENGINEERING ARE NOT RESPONSIBLE FOR CONSTRUCTION METHODS, MEANS, TECHNIQUES OR PROCEDURES GENERALLY OR FOR THE CONSTRUCTION MEANS METHODS TECHNIQUES OR PROCEDURES FOR COMPLETION OF THE WORK DEPICTED BOTH ON THESE PLANS, AND FOR ANY CONFLICTS IN SCOPE AND REVISIONS THAT RESULT FROM SAME. THE CONTRACTOR IS FULLY AND SOLELY RESPONSIBLE FOR DETERMINING THE MEANS AND METHODS FOR COMPLETION OF THE WORK, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 23. NEITHER THE PROFESSIONAL ACTIVITIES OF: BOHLER ENGINEERING, NOR THE PRESENCE OF BOHLER ENGINEERING AND/OR ITS PAST, PRESENT AND FUTURE OWNERS, OFFICERS, DIRECTORS, PARTNERS, SHAREHOLDERS, MEMBERS, PRINCIPALS, COMMISSIONERS AGENTS SERVANTS EMPLOYEES AFFILIATES SUBSIDIARIES AND RELATED ENTITIES AND ITS SUBCONTRACTORS AND SUBCONSULTANTS AT A CONSTRUCTION/PROJECT SITE (HEREIN "BOHLER ENGINEERING PARTIES"), RELIEVES OR WILL RELIEVE THE CONTRACTOR OF AND FROM ITS OBLIGATIONS, DUTIES AND RESPONSIBILITIES INCLUDING BUT NOT LIMITED TO CONSTRUCTION MEANS METHODS SEQUENCE TECHNIQUES OR PROCEDURES NECESSARY FOR PERFORMING, OVERSEEING, SUPERINTENDING AND COORDINATING THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND COMPLIANCE WITH ALL HEALTH AND SAFETY PRECAUTIONS REQUIRED BY ANY REGULATORY AGENCIES WITH JURISDICTION OVER THE PROJECT AND/OR PROPERTY. BOHLER ENGINEERING AND ITS EMPLOYEES, PERSONNEL, AGENTS, SUBCONTRACTORS AND SUBCONSULTANTS HAVE NO AUTHORITY TO EXERCISE ANY CONTROL OVER (OR ANY RESPONSIBILITY FOR) ANY CONSTRUCTION, THE CONTRACTOR OR ITS EMPLOYEES RELATING TO THEIR WORK AND ANY AND ALL HEALTH AND SAFETY PROGRAMS OR PROCEDURES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR JOB SITE SAFETY. THE CONTRACTOR MUST INDEMNIFY, DEFEND, PROTECT AND HOLD HARMLESS BOHLER ENGINEERING FOR AND FROM ANY LIABILITY TO BOHLER ENGINEERING RESULTING FROM THE CONTRACTOR'S WORK, SERVICES AND/OR VIOLATIONS OF THIS NOTE, THESE NOTES OR ANY NOTES IN THE PLAN SET AND, FURTHER, THE CONTRACTOR MUST NAME BOHLER ENGINEERING AS AN ADDITIONAL INSURED UNDER THE GENERAL CONTRACTOR'S POLICIES OF GENERAL LIABILITY INSURANCE AS DESCRIBED ABOVE. 24. WHEN IT IS CLEARLY AND SPECIFICALLY WITHIN BOHLER ENGINEERING'S SCOPE OF SERVICES CONTRACT WITH THE OWNER/DEVELOPER, BOHLER ENGINEERING WILL REVIEW OR TAKE OTHER APPROPRIATE ACTION ON THE CONTRACTOR SUBMITTALS, SUCH AS SHOP DRAWINGS, PRODUCT DATA, SAMPLES, AND OTHER DATA, WHICH THE CONTRACTOR IS REQUIRED TO SUBMIT, BUT ONLY FOR THE LIMITED PURPOSE OF EVALUATING CONFORMANCE WITH THE DESIGN INTENT AND THE INFORMATION SHOWN IN THE CONSTRUCTION CONTRACT DOCUMENTS. CONSTRUCTION MEANS AND METHODS AND/OR TECHNIQUES OR PROCEDURES, COORDINATION OF THE WORK WITH OTHER TRADES, AND CONSTRUCTION SAFETY PRECAUTIONS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND BOHLER ENGINEERING HAS NO RESPONSIBILITY OR LIABILITY FOR SAME. BOHLER ENGINEERING WILL PERFORM ITS SHOP DRAWING REVIEW WITH REASONABLE PROMPTNESS, AS CONDITIONS PERMIT. ANY DOCUMENT, DOCUMENTING BOHLER ENGINEERING'S REVIEW OF A SPECIFIC ITEM OR LIMITED SCOPE, MUST NOT INDICATE THAT BOHLER ENGINEERING HAS REVIEWED THE ENTIRE ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. BOHLER ENGINEERING IS NOT RESPONSIBLE FOR ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR MUST, IN WRITING, PROMPTLY AND IMMEDIATELY BRING ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS TO BOHLER ENGINEERING'S ATTENTION. BOHLER ENGINEERING IS NOT REQUIRED TO REVIEW PARTIAL SUBMISSIONS OR THOSE FOR WHICH SUBMISSIONS OF CORRELATED ITEMS HAVE NOT BEEN RECEIVED. 25. IF THE CONTRACTOR DEVIATES FROM THESE PLANS AND/OR SPECIFICATIONS, INCLUDING THE NOTES CONTAINED HEREIN, WITHOUT FIRST OBTAINING THE PRIOR WRITTEN AUTHORIZATION OF THE ENGINEER OF RECORD AND/OR BOHLER ENGINEERING FOR ALL DEVIATIONS WITHIN ENGINEER'S SCOPE, THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE PAYMENT OF ALL COSTS INCURRED IN CORRECTING ANY WORK PERFORMED WHICH DEVIATES FROM THE PLANS, ALL FINES AND/OR PENALTIES ASSESSED WITH RESPECT THERETO AND ALL COMPENSATORY OR PUNITIVE DAMAGES RESULTING THEREFROM AND, FURTHER, MUST DEFEND, INDEMNIFY, PROTECT, AND HOLD HARMLESS THE ENGINEER OF RECORD AND BOHLER ENGINEERING PARTIES TO THE FULLEST EXTENT PERMITTED UNDER THE LAW, FOR AND FROM ALL FEES, ATTORNEYS' FEES, DAMAGES, COSTS, JUDGMENTS CLAIMS INJURIES PENALTIES AND THE LIKE RELATED TO SAME. 26. THE CONTRACTOR IS RESPONSIBLE FOR A MAINTAINING AND PROTECTING THE TRAFFIC CONTROL PLAN AND ELEMENTS IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS, FOR ALL WORK THAT AFFECTS PUBLIC TRAVEL EITHER IN THE RIGHT OF WAY OR ON SITE. THE COST FOR THIS ITEM MUST BE INCLUDED IN THE CONTRACTOR'S PRICE AND IS THE CONTRACTOR'S SOLE RESPONSIBILITY. 27. OWNER MUST MAINTAIN AND PRESERVE ALL PHYSICAL SITE FEATURES AND DESIGN FEATURES DEPICTED ON THE PLANS AND RELATED DOCUMENTS IN STRICT ACCORDANCE WITH THE APPROVED PLAN(S) AND DESIGN; AND, FURTHER, THE ENGINEER OF RECORD AND/OR BOHLER ENGINEERING ARE NOT RESPONSIBLE FOR ANY FAILURE TO SO MAINTAIN OR PRESERVE SITE AND/OR DESIGN FEATURES. IF OWNER FAILS TO MAINTAIN AND/OR PRESERVE ALL PHYSICAL SITE FEATURES AND/OR DESIGN FEATURES DEPICTED ON THE PLANS AND RELATED DOCUMENTS, OWNER AGREES TO INDEMNIFY AND HOLD THE ENGINEER OF RECORD AND BOHLER ENGINEERING PARTIES, HARMLESS FOR ALL INJURIES, DAMAGES AND COSTS THAT ENGINEER OF RECORD AND/OR BOHLER ENGINEERING INCUR AS A RESULT OF SAID FAILURE OR FAILURE TO PRESERVE. 28. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ENSURING THAT ALL CONSTRUCTION ACTIVITIES AND MATERIALS COMPLY WITH AND CONFORM TO APPLICABLE FEDERAL STATE AND LOCAL RULES AND REGULATIONS LAWS ORDINANCES AND CODES AND ALL APPLICABLE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 29 U.S.C. 651 ET SEQ. AS AMENDED AND ANY MODIFICATIONS, AMENDMENTS OR REVISIONS TO SAME. 29. THE CONTRACTOR MUST STRICTLY COMPLY WITH THE LATEST AND CURRENT OSHA STANDARDS AND REGULATIONS, AND/OR ANY OTHER AGENCY WITH JURISDICTION OVER EXCAVATION AND TRENCHING PROCEDURES. ENGINEER OF RECORD AND BOHLER ENGINEERING HAS NO RESPONSIBILITY FOR OR AS RELATED TO EXCAVATION AND TRENCHING PROCEDURES AND WORK. 30. THE CONTRACTOR AND THE OWNER MUST INSTALL ALL ELEMENTS AND COMPONENTS IN STRICT COMPLIANCE WITH AND IN ACCORDANCE WITH MANUFACTURER'S STANDARDS AND RECOMMENDED INSTALLATION CRITERIAAND SPECIFICATIONS. IF THE CONTRACTOR AND/OR OWNER FAIL TO DO SO, THEY AGREE TO JOINTLY, INDEPENDENTLY, SEPARATELY, COLLECTIVELY, AND SEVERALLY INDEMNIFY, DEFEND, PROTECT AND HOLD ENGINEER OF RECORD AND/OR BOHLER ENGINEERING PARTIES HARMLESS FOR ALL INJURIES AND DAMAGES THAT ENGINEER SUFFERS AND COSTS THAT ENGINEER INCURS AS A RESULT OF SAID FAILURE. 31. THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN AN ON -SITE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) IN COMPLIANCE WITH THE ENVIRONMENTAL PROTECTION AGENCY (EPA) REQUIREMENTS OR LOCAL GOVERNING AGENCY FOR SITES WHERE ONE (1) ACRE OR MORE IS DISTURBED BY CONSTRUCTION ACTIVITIES (UNLESS THE LOCAL JURISDICTION REQUIRES A DIFFERENT THRESHOLD). THE CONTRACTOR MUST ENSURE THAT ALL ACTIVITIES, INCLUDING THOSE OF ALL SUBCONTRACTORS, ARE IN COMPLIANCE WITH THE SWPPP, INCLUDING BUT NOT LIMITED TO LOGGING ACTIVITIES (MINIMUM ONCE PER WEEK AND AFTER RAINFALL EVENTS) AND CORRECTIVE MEASURES, AS APPROPRIATE AND FURTHER, THE CONTRACTOR IS SOLELY AND COMPLETELY RESPONSIBLE FOR FAILING TO DO SO. 32. AS CONTAINED IN THESE DRAWINGS AND ASSOCIATED DOCUMENTS PREPARED BY THE SIGNATORY PROFESSIONAL ENGINEER OF RECORD, THE USE OF THE WORDS'CERTIFY' OR'CERTIFICATION' CONSTITUTE(S) AN EXPRESSION ONLY OF PROFESSIONAL OPINION REGARDING THE INFORMATION WHICH IS THE SUBJECT OF THE ENGINEER OF RECORD'S KNOWLEDGE OR BELIEF AND IN ACCORDANCE WITH COMMON AND ACCEPTED PROCEDURE CONSISTENT WITH THE APPLICABLE STANDARDS OF PRACTICE, AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE OF ANY NATURE OR TYPE, EITHER EXPRESSED OR IMPLIED, UNDER ANY CIRCUMSTANCES. (Rev. 1 /2019) 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 2. PRIOR TO THE COMMENCEMENT OF GENERAL CONSTRUCTION, THE CONTRACTOR MUST INSTALL SOIL EROSION CONTROL AND ANY STORMWATER POLLUTION PREVENTION PLAN (SWPPP) MEASURES NECESSARY, AS INDICATED ON THE APPROVED SOIL EROSION AND SEDIMENT CONTROL PLAN AND IN ACCORDANCE WITH APPLICABLE AND/OR APPROPRIATE AGENCIES' GUIDELINES TO PREVENT SEDIMENT AND/OR LOOSE DEBRIS FROM WASHING ONTO ADJACENT PROPERTIES OR THE RIGHT OF WAY. 3. ALL DIRECTIONAUTRAFFIC SIGNING AND PAVEMENT STRIPING MUST CONFORM TO THE LATEST STANDARDS OF THE MANUAL ON UNIFORM TRAFFIC CONTROL (MUTCD) AND ANY APPLICABLE STATE OR LOCALLY APPROVED SUPPLEMENTS, GUIDELINES, RULES, REGULATIONS, STANDARDS AND THE LIKE. 4. THE LOCATIONS OF PROPOSED UTILITY POLES AND TRAFFIC SIGNS SHOWN ON THE PLANS ARE SCHEMATIC AND PRELIMINARY. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR FIELD -VERIFYING THEIR LOCATION. THE CONTRACTOR MUST COORDINATE THE RELOCATION OF TRAFFIC SIGNS WITH THE ENTITY WITH JURISDICTION OVER THE PROJECT. 5. ALL DIMENSIONS SHOWN ARE TO BOTTOM FACE OF CURB, EDGE OF PAVEMENT, OR EDGE OF BUILDING, EXCEPT WHEN DIMENSION IS TO A PROPERTY LINE, STAKE OUT OF LOCATIONS OF INLETS, LIGHT POLES, ETC. MUST BE PERFORMED IN STRICT ACCORDANCE WITH THE DETAILS, UNLESS NOTED CLEARLY OTHERWISE. GRADING NOTES (Rev.1/2019) 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 2. SITE GRADING MUST BE PERFORMED IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS AND THE RECOMMENDATIONS SET FORTH IN THE GEOTECHNICAL REPORT AS REFERENCED IN THIS PLAN SET. IF NO GEOTECHNICAL REPORT HAS BEEN REFERENCED, THE CONTRACTOR MUST HAVE A GEOTECHNICAL ENGINEER PROVIDE WRITTEN SPECIFICATIONS AND RECOMMENDATIONS PRIOR TO THE CONTRACTOR COMMENCING THE GRADING WORK. THE CONTRACTOR MUST FOLLOW THE REQUIREMENTS OF ALL MUNICIPAL, COUNTY, STATE, AND FEDERAL LAWS, WHICH HAVE JURISDICTION OVER THIS PROJECT. 3. THE CONTRACTOR IS REQUIRED TO SECURE ALL NECESSARY AND/OR REQUIRED PERMITS AND APPROVALS FOR ALL OFF -SITE MATERIAL SOURCES AND DISPOSAL FACILITIES. THE CONTRACTOR MUST SUPPLY A COPY OF APPROVALS TO THE ENGINEER OF RECORD AND THE OWNER PRIOR TO THE CONTRACTOR COMMENCING ANY WORK. 4. THE CONTRACTOR IS FULLY RESPONSIBLE FOR VERIFYING EXISTING TOPOGRAPHIC INFORMATION AND UTILITY INVERT ELEVATIONS PRIOR TO COMMENCING ANY CONSTRUCTION. SHOULD DISCREPANCIES BETWEEN THE PLANS AND INFORMATION OBTAINED THROUGH FIELD VERIFICATIONS BE IDENTIFIED OR EXIST, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN WRITING. 5. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING AND REPLACING ALL UNSUITABLE MATERIALS WITH SUITABLE MATERIALS AS SPECIFIED IN THE GEOTECHNICAL REPORT. THE CONTRACTOR MUST COMPACT ALL EXCAVATED OR FILLED AREAS IN STRICT ACCORDANCE WITH THE GEOTECHNICAL REPORT'S GUIDANCE. MOISTURE CONTENT AT TIME OF PLACEMENT MUST BE SUBMITTED IN A COMPACTION REPORT PREPARED BY A QUALIFIED GEOTECHNICAL ENGINEER, REGISTERED WITH THE STATE WHERE THE WORK IS PERFORMED. THIS REPORT MUST VERIFY THAT ALL FILLED AREAS AND SUBGRADE AREAS WITHIN THE BUILDING PAD AREA AND AREAS TO BE PAVED HAVE BEEN COMPACTED IN ACCORDANCE WITH THESE PLANS, SPECIFICATIONS AND THE RECOMMENDATIONS SET FORTH IN THE GEOTECHNICAL REPORT AND ALL APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES WHICH ARE IN EFFECT AND WHICH ARE APPLICABLE TO THE PROJECT. SUBBASE MATERIAL FOR SIDEWALKS, CURB, OR ASPHALT MUST BE FREE OF ORGANICS AND OTHER UNSUITABLE MATERIALS. SHOULD SUBBASE BE DEEMED UNSUITABLE BY OWNER/DEVELOPER, OR OWNER/DEVELOPER'S REPRESENTATIVE, SUBBASE MUST BE REMOVED AND FILLED WITH APPROVED FILL MATERIAL, COMPACTED AS THE GEOTECHNICAL REPORT DIRECTS. EARTHWORK ACTIVITIES INCLUDING, BUT NOT LIMITED TO, EXCAVATION, BACKFILL, AND COMPACTING MUST COMPLY WITH THE RECOMMENDATIONS IN THE GEOTECHNICAL REPORT AND ALL APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES. EARTHWORK ACTIVITIES MUST COMPLY WITH THE STANDARD STATE DOT SPECIFICATIONS FOR ROADWAY CONSTRUCTION (LATEST EDITION) AND ANY AMENDMENTS OR REVISIONS THERETO. 6. THE TOPS OF EXISTING MANHOLES, INLET STRUCTURES, AND SANITARY CLEANOUT TOPS MUST BE ADJUSTED, AS NECESSARY, TO MATCH PROPOSED FINISHED GRADES WITH NO TRIPPING OR SAFETY HAZARD IN ACCORDANCE WITH ALL APPLICABLE STANDARDS, REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES. 7. IN THE EVENT OF A DISCREPANCY(IES) AND/OR A CONFLICT(S) BETWEEN PLANS, OR RELATIVE TO OTHER PLANS, THE GRADING PLAN TAKES PRECEDENCE AND CONTROLS. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN WRITING, OF ANY DISCREPANCY(IES) AND/OR CONFLICT(S). 8. THE CONTRACTOR IS RESPONSIBLE TO IMPORT FILL OR EXPORT EXCESS MATERIAL AS NECESSARY TO CONFORM TO THE PROPOSED GRADING, AND TO BACKFILL EXCAVATIO�NS7FOR THE INSTALLATION OF UNDERGROUND IMPROVEMENTS. ACC ESSIBI]IoITY DESIGN GUID ELINE� (Rev.1/2019) 1. ALL ACCESSIBLE (A.K.A. ADA) COMPONENTS AND ACCESSIBLE ROUTES MUST BE CONSTRUCTED TO MEET, AT A MINIMUM, THE MORE STRINGENT OF: (A) THE REQUIREMENTS OF THE "AMERICANS WITH DISABILITIES ACT" (ADA) CODE (42 U.S.C. § 12101 ET SEC. AND 42 U.S.C. § 4151 ET SEQ.); AND (B) ANY APPLICABLE LOCAL AND STATE GUIDELINES, AND ANY AND ALL AMENDMENTS TO BOTH, WHICH ARE IN EFFECT WHEN THESE PLANS WERE COMPLETED. 2. THE CONTRACTOR MUST REVIEW ALL DOCUMENTS REFERENCED IN THESE NOTES FOR ACCURACY, COMPLIANCE AND CONSISTENCY WITH INDUSTRY GUIDELINES. 3. THE CONTRACTOR MUST EXERCISE APPROPRIATE CARE AND PRECISION IN CONSTRUCTION OF ACCESSIBLE (ADA) COMPONENTS AND ACCESSIBLE ROUTES FOR THE SITE. FINISHED SURFACES ALONG THE ACCESSIBLE ROUTE OF TRAVEL FROM PARKING SPACES, PUBLIC TRANSPORTATION, PEDESTRIAN ACCESS, AND INTER -BUILDING ACCESS, TO POINTS OF ACCESSIBLE BUILDING ENTRANCE/EXIT, MUST COMPLY WITH THE ACCESSIBLE GUIDELINES AND REQUIREMENTS WHICH INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: A. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SLOPES MUST NOT EXCEED 1:50 (2.0%) IN ANY DIRECTION. B. PATH OF TRAVEL ALONG ACCESSIBLE ROUTE MUST PROVIDE A 36-INCHES MINIMUM WIDTH (48-INCHES PREFERRED), OR AS SPECIFIED BY THE GOVERNING AGENCY. UNOBSTRUCTED WIDTH OF TRAVEL (CAR OVERHANGS AND/OR HANDRAILS) MUST NOT REDUCE THIS MINIMUM WIDTH. THE SLOPE MUST NOT EXCEED 1:20 (5.0%) IN THE DIRECTION OF TRAVEL AND MUST NOT EXCEED 1:50 (2.0%) IN CROSS SLOPE. WHERE ACCESSIBLE PATH OF TRAVEL IS GREATER THAN 1:20 (5.0%), AN ACCESSIBLE RAMP MUST BE PROVIDED. ALONG THE ACCESSIBLE PATH OF TRAVEL, OPENINGS MUST NOT EXCEED 1/2-INCH IN WIDTH. VERTICAL CHANGES OF UP TO 1/2-INCH ARE PERMITTED ONLY IF THEY INCLUDES A 1/4-INCH BEVEL AT A SLOPE NOT STEEPER THAN 1:2. NO VERTICAL CHANGES OVER 1/4-INCH ARE PERMITTED. C. ACCESSIBLE RAMPS MUST NOT EXCEED A SLOPE OF 1:12 (8.3%) AND A RISE OF 30-INCHES. LEVEL LANDINGS MUST BE PROVIDED AT EACH END OF ACCESSIBLE RAMPS. LANDING MUST PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURES, AND MUST NOT EXCEED 1:50 (2.0%) SLOPE IN ANY DIRECTION. RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS MUST HAVE A CLEAR LANDING OF A MINIMUM OF 60-INCHES BY 60-INCHES. HAND RAILS ON BOTH SIDES OF THE RAMP MUST BE PROVIDED ON AN ACCESSIBLE RAMP WITH A RISE GREATER THAN 6-INCHES. D. ACCESSIBLE CURB RAMPS MUST NOT EXCEED A SLOPE OF 1:12 8.3 /o .WHERE FLARED SIDES ARE PROVIDED THEY MUST NOT EXCEED 1:10 (10%) SLOPE. LEVEL LANDING MUST BE PROVIDED AT RAMPS TOP AT A MINIMUM OF 36-INCHES LONG (48-INCHES PREFERRED). IN ALTERATIONS, WHEN THERE IS NO LANDING AT THE TOP, FLARE SIDES SLOPES MUST NOT EXCEED A SLOPE OF 1:12 (8.3%). E. DOORWAY LANDINGS AREAS MUST BE PROVIDED ON THE EXTERIOR SIDE OF ANY DOOR LEADING TO AN ACCESSIBLE PATH OF TRAVEL. THIS LANDING MUST BE SLOPED AWAY FROM THE DOOR NO MORE THAN 1:50 (2.0%) FOR POSITIVE DRAINAGE. THIS LANDING AREA MUST BE NO FEWER THAN 60-INCHES (5 FEET) LONG, EXCEPT WHERE OTHERWISE CLEARLY PERMITTED BY ACCESSIBLE STANDARDS FOR ALTERNATIVE DOORWAY OPENING CONDITIONS. (SEE ICC/ANSI A117.1-2009 AND OTHER REFERENCES INCORPORATED BY CODE). F. WHEN THE PROPOSED CONSTRUCTION INVOLVES RECONSTRUCTION, MODIFICATION, REVISION OR EXTENSION OF OR TO ACCESSIBLE COMPONENTS FROM EXISTING DOORWAYS OR SURFACES, THE CONTRACTOR MUST VERIFY ALL EXISTING ELEVATIONS SHOWN ON THE PLAN. NOTE THAT TABLE 405.2 OF THE DEPARTMENT OF JUSTICE'S ADA STANDARDS FOR ACCESSIBLE DESIGN ALLOWS FOR STEEPER RAMP SLOPES, IN RARE CIRCUMSTANCES. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN WRITING, OF ANY DISCREPANCIES AND/OR FIELD CONDITIONS THAT DIFFER IN ANY WAY OR IN ANY RESPECT FROM WHAT IS SHOWN ON THE PLANS BEFORE COMMENCING ANY WORK. CONSTRUCTED IMPROVEMENTS MUST FALL WITHIN THE MAXIMUM AND MINIMUM LIMITATIONS IMPOSED BY THE BARRIER FREE REGULATIONS AND THE ACCESSIBLE GUIDELINES. G. THE CONTRACTOR MUST VERIFY ALL OF THE SLOPES OF THE CONTRACTOR'S FORMS PRIOR TO POURING CONCRETE. IF ANY NON-CONFORMANCE EXISTS OR IS OBSERVED OR DISCOVERED, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN WRITING, PRIOR TO POURING CONCRETE. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL COSTS TO REMOVE, REPAIR AND/OR REPLACE NON -CONFORMING CONCRETE AND/OR PAVEMENT SURFACES. 4. IT IS STRONGLY RECOMMENDED THAT THE CONTRACTOR REVIEW THE INTENDED CONSTRUCTION TO ENSURE SAME IS CONSISTENT WITH THE LOCAL BUILDING CODE PRIOR TO COMMENCING CONSTRUCTION. (Rev. 1 /2019) 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 2. THE CONTRACTOR MUST CONDUCT DEMOLITION/REMOVALS ACTIVITIES IN SUCH A MANNER AS TO ENSURE MINIMUM INTERFERENCE WITH ROADS STREETS SIDEWALKS WALKWAYS AND ALL OTHER ADJACENT FACILITIES. THE CONTRACTOR MUST OBTAIN ALL APPLICABLE PERMITS FROM THE APPROPRIATE GOVERNMENTAL AUTHORITY IES PRIOR TO THE COMMENCEMENT OF ANY ROAD OPENING OR DEMOLITION ACTIVITIES IN OR ADJACENT TO THE RIGHT-OF-WAY. 3. WHEN DEMOLITION -RELATED ACTIVITIES IMPACT ROADWAYS AND/OR ROADWAY RIGHT-OF-WAY THE CONTRACTOR MUST PROVIDE TRAFFIC CONTROL AND GENERALLY ACCEPTED SAFE PRACTICES IN CONFORMANCE WITH THE CURRENT FEDERAL HIGHWAY ADMINISTRATION "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" MUTCD AND THE FEDERAL STATE AND LOCAL REGULATIONS. 4. THE DEMOLITION AND/OR REMOVALS PLAN IS INTENDED TO PROVIDE GENERAL INFORMATION AND TO IDENTIFY ONLY CONDITIONS REGARDING ITEMS TO BE DEMOLISHED, REMOVED, AND/OR TO REMAIN. A. THE CONTRACTOR MUST ALSO REVIEW ALL CONSTRUCTION DOCUMENTS AND INCLUDE WITHIN THE DEMOLITION ACTIVITIES ALL INCIDENTAL WORK NECESSARY FOR THE CONSTRUCTION OF THE NEW SITE IMPROVEMENTS. B. THIS PLAN IS NOT INTENDED TO AND DOES NOT PROVIDE DIRECTION REGARDING THE MEANS METHODS SEQUENCING TECHNIQUES AND PROCEDURES TO BE EMPLOYED TO ACCOMPLISH THE WORK. ALL MEANS, METHODS, SEQUENCING, TECHNIQUES AND PROCEDURES TO BE USED MUST BE IN STRICT ACCORDANCE AND CONFORMANCE WITH ALL STATE, FEDERAL, LOCAL, AND JURISDICTIONAL REQUIREMENTS. THE CONTRACTOR MUST COMPLY WITH ALL OSHA AND OTHER SAFETY PRECAUTIONS NECESSARY TO PROVIDE A SAFE WORK SITE FOR THE CONTRACTOR AND THE PUBLIC. 5. THE CONTRACTOR MUST PROVIDE ALL "METHODS AND MEANS" NECESSARY TO PREVENT MOVEMENT SETTLEMENT OR COLLAPSE OF EXISTING STRUCTURES AND ANY OTHER IMPROVEMENTS THAT ARE REMAINING ON OR OFF SITE. THE CONTRACTOR AT THE CONTRACTOR'S SOLE COST MUST REPAIR ALL DAMAGE TO ALL ITEMS AND FEATURES THAT ARE TO REMAIN. CONTRACTOR MUST USE NEW MATERIAL FOR ALL REPAIRS. CONTRACTOR'S REPAIRS MUST INCLUDE THE RESTORATION OF ALL ITEMS AND FEATURES REPAIRED TO THEIR PRE -DEMOLITION CONDITION, OR BETTER. CONTRACTOR MUST PERFORM ALL REPAIRS AT THE CONTRACTOR'S SOLE EXPENSE. 6. ENGINEER OF RECORD AND/OR BOHLER ENGINEERING ARE NOT RESPONSIBLE FOR JOB SITE SAFETY OR SUPERVISION. THE CONTRACTOR MUST PROCEED WITH THE DEMOLITION IN A SYSTEMATIC AND SAFE MANNER, COMPLYING WITH ALL OSHA REQUIREMENTS, TO ENSURE PUBLIC AND CONTRACTOR SAFETY AND SAFETY TO ALL PROPERTY ON THE SITE OR ADJACENT OR NEAR TO THE SAME. 7. THE CONTRACTOR IS RESPONSIBLE FOR JOB SITE SAFETY, WHICH MUST INCLUDE, BUT IS NOT LIMITED TO, THE INSTALLATION AND MAINTENANCE OF BARRIERS, FENCING, OTHER APPROPRIATE AND/OR NECESSARY SAFETY FEATURES AND ITEMS NECESSARY TO PROTECT THE PUBLIC FROM AREAS OF CONSTRUCTION AND CONSTRUCTION ACTIVITIES. THE CONTRACTOR MUST SAFEGUARD THE SITE AS NECESSARY TO PERFORM THE DEMOLITION IN SUCH A MANNER AS TO PREVENT THE ENTRY OF ALL UNAUTHORIZED PERSONS AT ANY TIME, TO OR NEAR THE DEMOLITION AREA. 8. PRIOR TO THE COMMENCEMENT OF ANY SITE ACTIVITY AND ANY DEMOLITION ACTIVITY, THE CONTRACTOR MUST, IN WRITING, RAISE ANY QUESTIONS CONCERNING THE ACCURACY OR INTENT OF THESE PLANS AND/OR SPECIFICATIONS, ALL CONCERNS OR QUESTIONS REGARDING THE APPLICABLE SAFETY STANDARDS, AND/OR THE SAFETY OF THE CONTRACTOR AND/OR THIRD PARTIES IN PERFORMING THE WORK ON THIS PROJECT. ANY SUCH CONCERNS MUST BE CONVEYED TO THE ENGINEER OF RECORD AND/OR BOHLER ENGINEERING, IN WRITING AND MUST ADDRESS ALL ISSUES AND ITEMS RESPONDED TO, BY THE ENGINEER OF RECORD AND/OR BY BOHLER ENGINEERING, IN WRITING. ALL DEMOLITION ACTIVITIES MUST BE PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS AND SPECIFICATIONS AND ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS, RULES, REQUIREMENTS, STATUTES, ORDINANCES AND CODES. 9. THE CONTRACTOR MUST BECOME FAMILIAR WITH THE APPLICABLE UTILITY SERVICE PROVIDER REQUIREMENTS AND IS RESPONSIBLE FOR ALL COORDINATION REGARDING UTILITY DEMOLITION AND/OR DISCONNECTION AS IDENTIFIED OR REQUIRED FOR THE PROJECT. THE CONTRACTOR MUST PROVIDE THE OWNER WITH WRITTEN NOTIFICATION THAT THE EXISTING UTILITIES AND SERVICES HAVE BEEN TERMINATED, REMOVED AND/OR ABANDONED IN ACCORDANCE WITH THE JURISDICTION AND UTILITY COMPANY REQUIREMENTS AND ALL OTHER APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES. 10. PRIOR TO COMMENCING ANY DEMOLITION, THE CONTRACTOR MUST: A. OBTAIN ALL REQUIRED PERMITS AND MAINTAIN THE SAME ON SITE FOR REVIEW BY THE ENGINEER AND ALL PUBLIC AGENCIES WITH JURISDICTION THROUGHOUT THE DURATION OF THE PROJECT, SITE WORK, AND DEMOLITION WORK. B. NOTIFY, AT A MINIMUM, THE MUNICIPAL ENGINEER, DESIGN ENGINEER, AND LOCAL SOIL CONSERVATION JURISDICTION, AT LEAST 72 BUSINESS HOURS PRIOR TO THE COMMENCEMENT OF WORK. C. INSTALL THE REQUIRED SOIL EROSION AND SEDIMENT CONTROL MEASURES PRIOR TO SITE DISTURBANCE, AND MAINTAIN SAID CONTROLS UNTIL SITE IS STABILIZED D. IN ACCORDANCE WITH STATE LAW, THE CONTRACTOR MUST CALL THE STATE ONE -CALL DAMAGE PROTECTION SYSTEM FOR UTILITY MARK OUT, IN ADVANCE OF ANY EXCAVATION. E. LOCATE AND PROTECT ALL UTILITIES AND SERVICES, INCLUDING BUT NOT LIMITED TO GAS, WATER, ELECTRIC, SANITARY AND STORM SEWER, TELEPHONE, CABLE, FIBER OPTIC CABLE, ETC. WITHIN AND ADJACENT TO THE LIMITS OF PROJECT ACTIVITIES. THE CONTRACTOR MUST USE AND COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE UTILITY NOTIFICATION SYSTEM TO LOCATE ALL UNDERGROUND UTILITIES. F. PROTECT AND MAINTAIN IN OPERATION, ALL ACTIVE UTILITIES AND SYSTEMS THAT ARE NOT BEING REMOVED DURING ANY DEMOLITION ACTIVITIES. G. ARRANGE FOR AND COORDINATE WITH THE APPLICABLE UTILITY SERVICE PROVIDER(S) FOR THE TEMPORARY OR PERMANENT TERMINATION OF SERVICE REQUIRED BY THE PROJECT PLANS AND SPECIFICATIONS REGARDING THE METHODS AND MEANS TO CONSTRUCT SAME. THESE ARE NOT THE ENGINEER OF RECORD'S RESPONSIBILITY. IN THE EVENT OF ABANDONMENT, THE CONTRACTOR MUST PROVIDE THE UTILITY ENGINEER AND OWNER WITH IMMEDIATE WRITTEN NOTIFICATION THAT THE EXISTING UTILITIES AND SERVICES HAVE BEEN TERMINATED AND ABANDONED IN ACCORDANCE WITH JURISDICTIONAL AND UTILITY COMPANY REQUIREMENTS. H. ARRANGE FOR AND COORDINATE WITH THE APPLICABLE UTILITY SERVICE PROVIDER(S) REGARDING WORKING "OFF-PEAK" HOURS OR ON WEEKENDS AS NECESSARY OR AS REQUIRED TO MINIMIZE THE IMPACT ON, OF AND TO THE AFFECTED PARTIES. WORK REQUIRED TO BE PERFORMED "OFF-PEAK" IS TO BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. I. IN THE EVENT THE CONTRACTOR DISCOVERS ANY HAZARDOUS MATERIAL, THE REMOVAL OF WHICH IS NOT ADDRESSED IN THE PROJECT PLANS AND SPECIFICATIONS, OR THE CONTRACT WITH THE OWNER/DEVELOPER, THE CONTRACTOR MUST IMMEDIATELY CEASE ALL WORK IN THE AREA OF DISCOVERY, AND IMMEDIATELY NOTIFY, IN WRITING AND VERBALLY, THE OWNER AND ENGINEER OF RECORD AND BOHLER ENGINEERING, THE DISCOVERY OF SUCH MATERIALS TO PURSUE PROPER AND COMPLIANT REMOVAL OF SAME. 11. THE CONTRACTOR MUST ENSURE THAT ANY EXISTING ASBESTOS -CONTAINING MATERIALS ENCOUNTERED ARE PROPERLY REMOVED FROM THE SUBJECT PREMISES AND ARE DISPOSED OF IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS, PRIOR TO THE COMMENCEMENT OF DEMOLITION ON SITE AND MUST PERFORM ALL AGENCY NOTIFICATIONS AS REQUIRED, AT THE CONTRACTOR'S SOLE EXPENSE. 12. THE CONTRACTOR MUST NOT PERFORM ANY EARTH MOVEMENT ACTIVITIES, DEMOLITION OR REMOVAL OF FOUNDATION WALLS, FOOTINGS, OR OTHER MATERIALS WITHIN THE LIMITS OF DISTURBANCE, UNLESS SAME IS IN STRICT ACCORDANCE AND CONFORMANCE WITH THE PROJECT PLANS AND SPECIFICATIONS, OR PURSUANT TO THE WRITTEN DIRECTION OF THE OWNER'S STRUCTURAL OR GEOTECHNICAL ENGINEER. 13. DEMOLITION ACTIVITIES AND EQUIPMENT MUST NOT USE OR INCLUDE AREAS OUTSIDE THE DEFINED PROJECT LIMIT LINE, WITHOUT SPECIFIC WRITTEN PERMISSION AND AUTHORITY OF AND FROM THE OWNER AND ALL GOVERNMENTAL AGENCIES WITH JURISDICTION. 14. THE CONTRACTOR MUST BACKFILL ALL EXCAVATION RESULTING FROM, OR INCIDENTAL TO, DEMOLITION ACTIVITIES. BACKFILL MUST BE ACCOMPLISHED WITH APPROVED BACKFILL MATERIALS AND MUST BE SUFFICIENTLY COMPACTED TO SUPPORT ALL NEW IMPROVEMENTS AND MUST BE PERFORMED IN COMPLIANCE WITH THE RECOMMENDATIONS AND GUIDANCE ARTICULATED IN THE GEOTECHNICAL REPORT. BACKFILLING MUST OCCUR IMMEDIATELY AFTER DEMOLITION ACTIVITIES AND MUST BE PERFORMED SO AS TO PREVENT WATER ENTERING THE EXCAVATION. FINISHED SURFACES MUST BE GRADED TO PROMOTE POSITIVE DRAINAGE. THE CONTRACTOR IS RESPONSIBLE FOR COMPACTION TESTING AND MUST SUBMIT SUCH REPORTS AND RESULTS TO THE ENGINEER OF RECORD AND THE OWNER. 15. EXPLOSIVES MUST NOT BE USED WITHOUT PRIOR WRITTEN CONSENT FROM BOTH THE OWNER AND ALL APPLICABLE, NECESSARY AND REQUIRED GOVERNMENTAL AUTHORITIES. PRIOR TO COMMENCING ANY EXPLOSIVE PROGRAM AND/OR ANY DEMOLITION ACTIVITIES, THE CONTRACTOR MUST ENSURE AND OVERSEE THE INSTALLATION OF ALL OF THE REQUIRED PERMIT AND EXPLOSIVE CONTROL MEASURES THAT THE FEDERAL, STATE, AND LOCAL GOVERNMENTS REQUIRE. THE CONTRACTOR IS ALSO RESPONSIBLE TO CONDUCT AND PERFORM ALL INSPECTION AND SEISMIC VIBRATION TESTING THAT IS REQUIRED TO MONITOR THE EFFECTS ON ALL LOCAL STRUCTURES AND THE LIKE. 16. IN ACCORDANCE WITH FEDERAL, STATE, AND/OR LOCAL STANDARDS, THE CONTRACTOR MUST USE DUST CONTROL MEASURES TO LIMIT AIRBORNE DUST AND DIRT RISING AND SCATTERING IN THE AIR. AFTER THE DEMOLITION IS COMPLETE, THE CONTRACTOR MUST CLEAN ALL ADJACENT STRUCTURES AND IMPROVEMENTS TO REMOVE ALL DUST AND DEBRIS WHICH THE DEMOLITION OPERATIONS CAUSE. THE CONTRACTOR IS RESPONSIBLE FOR RETURNING ALL ADJACENT AREAS TO THEIR "PRE -DEMOLITION" CONDITION AT CONTRACTOR'S SOLE COST. 17. PAVEMENT MUST BE SAW CUT IN STRAIGHT LINES, AND EXCEPT FOR EDGE OF BUTT JOINTS, MUST EXTEND TO THE FULL DEPTH OF THE EXISTING PAVEMENT. ALL DEBRIS FROM REMOVAL OPERATIONS MUST BE REMOVED FROM THE SITE AT THE TIME OF EXCAVATION. STOCKPILING OF DEBRIS OUTSIDE OF APPROVED AREAS WILL NOT BE PERMITTED, INCLUDING BUT NOT LIMITED TO, THE PUBLIC RIGHT-OF-WAY. 18. THE CONTRACTOR MUST MAINTAIN A RECORD SET OF PLANS UPON WHICH IS INDICATED THE LOCATION OF EXISTING UTILITIES THAT ARE CAPPED, ABANDONED IN PLACE, OR RELOCATED DUE TO DEMOLITION ACTIVITIES. THIS RECORD DOCUMENT MUST BE PREPARED IN A NEAT AND WORKMAN -LIKE MANNER AND TURNED OVER TO THE OWNER/DEVELOPER UPON COMPLETION OF THE WORK, ALL OF WHICH IS AT THE CONTRACTOR'S SOLE COST. 19. THE CONTRACTOR MUST EMPTY, CLEAN AND REMOVE FROM THE SITE ALL UNDERGROUND STORAGE TANKS, IF ENCOUNTERED, IN ACCORDANCE WITH FEDERAL, STATE, COUNTY AND LOCAL REQUIREMENTS, PRIOR TO CONTINUING CONSTRUCTION IN THE AREA AROUND THE TANK WHICH EMPTYING, CLEANING AND REMOVAL ARE AT THE CONTRACTOR'S SOLE COST. LIG]HITING NOTES (Rev.1/2019) 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 2. THE LIGHTING CONTRACTOR MUST COMPLY WITH ALL APPLICABLE CONTRACTOR REQUIREMENTS INDICATED IN THE PLANS, INCLUDING BUT NOT LIMITED TO GENERAL NOTES, GRADING AND UTILITY NOTES, SITE SAFETY, AND ALL AGENCY AND GOVERNMENTAL REGULATIONS. 3. THIS LIGHTING PLAN DEPICTS PROPOSED SUSTAINED ILLUMINATION LEVELS CALCULATED USING DATA PROVIDED BY THE NOTED MANUFACTURER. ACTUAL SUSTAINED SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINAIRES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS, THE SERVICE LIFE OF EQUIPMENT AND LUMINAIRES AND OTHER RELATED VARIABLE FIELD CONDITIONS. 4. THE LIGHTING VALUES AND CALCULATION POINTS DEPICTED ON THIS PLAN ARE ALL ANALYZED ON A HORIZONTAL GEOMETRIC PLANE AT ELEVATION ZERO (GROUND LEVEL) UNLESS OTHERWISE NOTED. ILLUMINATION LEVELS ARE SHOWN IN FOOT-CANDLES. 5. THE LUMINAIRES, LAMPS AND LENSES MUST BE REGULARLY MAINTAINED TO ENSURE THAT THEY FUNCTION PROPERLY. THIS WORK MAY INCLUDE, BUT IS NOT LIMITED TO, VISUAL OBSERVATION, CLEANING OF LENSES, AND RE-LAMPING (IF NECESSARY) AT LEAST ONCE EVERY SIX (6) MONTHS. UPON COMPLETION AND OWNER'S ACCEPTANCE OF THE WORK ALL OF THE ABOVE OUTLINED AND DESCRIBED RESPONSIBILITIES SHALL BECOME SOLELY THE OWNER'S. 6. WHERE APPLICABLE, THE EXISTING CONDITION LIGHT LEVELS ILLUSTRATED ARE REPRESENTATIVE OF AN APPROXIMATION UTILIZING LABORATORY DATA FOR SIMILAR FIXTURES, UNLESS ACTUAL FIELD MEASUREMENTS ARE TAKEN WITH A LIGHT METER. DUE TO FACTORS SUCH AS FIXTURE MAINTENANCE, EQUIPMENT TOLERANCES, WEATHER CONDITIONS, ETC., ACTUAL LIGHT LEVELS MAY DIFFER. EXISTING LIGHT LEVELS DEPICTED ON THIS PLAN ARE TO BE CONSIDERED APPROXIMATE. 7. THIS LIGHTING PLAN IS INTENDED TO SHOW THE LOCATIONS AND TYPE OF LUMINAIRES. POWER SYSTEM, CONDUITS, WIRING AND OTHER ELECTRICAL COMPONENTS ARE SOLELY THE ARCHITECT'S, MECHANICAL ENGINEER'S AND/OR LIGHTING CONTRACTOR'S RESPONSIBILITY, AS INDICATED IN THE CONSTRUCTION CONTRACT DOCUMENTS. THESE ITEMS MUST BE INSTALLED AS REQUIRED BY STATE AND LOCAL REGULATIONS. CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF LIGHTING FIXTURES AND APPURTENANCES IN ACCORDANCE WITH ALL APPLICABLE BUILDING AND ELECTRICAL CODES. 8. THE CONTRACTOR MUST BRING IMMEDIATELY, IN WRITING, ANY LIGHT LOCATIONS THAT CONFLICT WITH DRAINAGE, UTILITIES, OR OTHER STRUCTURE(S) TO THE ENGINEER OF RECORD'S ATTENTION, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 9. THE LIGHTING CONTRACTOR MUST COORDINATE WITH THE PROJECT ARCHITECT REGARDING ANY AND ALL POWERS SOURCE FROM WITHIN THE BUILDING, AND TIMING DEVICES NECESSARY TO MEET THE DESIGN INTENT. 10. THE CONTRACTOR IS RESPONSIBLE TO ENSURE THAT SHIELDING AND OR ROTATED OPTICS ARE INSTALLED AS INDICATED ON THE PLAN IN ORDER TO ACHIEVE THE LIGHTING LEVELS THE REVIEWING AGENCY APPROVED. SOIL JEROSION & SEDIA�JLJENT CONTROL PLAN NOTES (Rev.1/2019) 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 2. EROSION CONTROL MEASURES MUST CONFORM TO THE NORTH CAROLINA GUIDELINES FOR URBAN EROSION AND SEDIMENT CONTROL UNLESS OTHERWISE NOTED, OR UNLESS ENGINEER CLEARLY AND SPECIFICALLY, IN WRITING, DIRECTS OTHERWISE. INSTALLATION OF EROSION CONTROL, CLEARING, AND SITE WORK MUST BE PERFORMED EXACTLY AS INDICATED IN THE EROSION CONTROL CONSTRUCTION NOTES. 3. THE DISTURBED LAND AREA OF THIS SITE IS APPROXIMATELY 1 � d ACRES. 4. THE FOLLOWING EROSION CONTROL MEASURES ARE PROPOSED FOR THIS SITE: A. STABILIZED CONSTRUCTION ENTRANCE/ EXIT - A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE/EXIT IS TO BE INSTALLED AT THE DESIGNATED LOCATION SHOWN ON THE PLAN. THIS AREA MUST BE GRADED SO THAT RUNOFF WATER WILL BE RETAINED ON -SITE. B. SEDIMENT FENCE - INSTALL SILT FENCE(S) AND/OR SILT SOCK AROUND ALL OF THE DOWNSLOPE PERIMETERS OF THE SITE, TEMPORARY FILL AND SOIL STOCKPILES. C. INSTALL FILTER FABRIC DROP INLET PROTECTION AROUND EACH DRAINAGE INLET AS DRAINAGE STRUCTURES ARE INSTALLED TO REDUCE THE QUANTITY OF SEDIMENT. INSTALL TEMPORARY INLET PROTECTION ON INLETS DOWNSLOPE FROM DISTURBANCE, WHICH MAY BE BEYOND THE LIMITS OF DISTURBED AREA. 5. INSTALLATION OF EROSION CONTROL DEVICES MUST BE IN ACCORDANCE WITH ALL OF THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR MUST INSPECT EROSION CONTROL MEASURES WEEKLY. THE CONTRACTOR MUST REMOVE ANY SILT DEPOSITS GREATER THAN 6" COLLECTED ON THE FILTER FABRIC AND/OR SILT SOCK BARRIERS AND EXCAVATE AND REMOVE ANY SILT FROM DROP INLET PROTECTION. 7. THE CONTRACTOR MUST APPLY TEMPORARY SEED AND MULCH TO ALL DISTURBED AREAS THAT WILL NOT BE BROUGHT TO FINISHED GRADE AND VEGETATED WITHIN 7 DAYS. WHEN AREAS ARE DISTURBED AFTER THE GROWING SEASON, THE CONTRACTOR MUST STABILIZE SAME WITH GEOTEXTILE FABRIC AND MAINTAIN SAME IN STRICT ACCORDANCE WITH BEST MANAGEMENT PRACTICES. 8. THE CONTRACTOR MUST INSTALL ADDITIONAL EROSION CONTROL MEASURES IF ENGINEER SO REQUIRES, TO PREVENT ANY, INCLUDING THE INCIDENTAL, DISCHARGE OF SILT -LADEN RUNOFF FROM EXITING THE SITE. 9. THE CONTRACTOR MUST BE RESPONSIBLE FOR INSPECTING AND MAINTAINING ALL EROSION CONTROL MEASURES ON THE SITE UNTIL PERMANENT PAVING AND TURF/LANDSCAPING IS ESTABLISHED. THE COSTS OF INSTALLING AND MAINTAINING THE EROSION CONTROL MEASURES MUST BE INCLUDED IN THE BID PRICE FOR THE SITE WORK AND THE CONTRACTOR IS RESPONSIBLE FOR ALL SUCH COSTS. 10. THE CONTRACTOR MUST CONTINUE TO MAINTAIN ALL EROSION CONTROL MEASURES UNTIL THE COMPLETION OF CONSTRUCTION AND THE ESTABLISHMENT OF VEGETATION. 11. THE CONTRACTOR MUST REMOVE EROSION CONTROL MEASURES, SILT AND DEBRIS AFTER ESTABLISHING PERMANENT VEGETATION COVER OR OTHER INSTALLING A DIFFERENT, SPECIFIED METHOD OF STABILIZATION. 12. THIS PLAN REPRESENTS THE MINIMUM LEVEL OF IMPLEMENTATION OF TEMPORARY EROSION AND SEDIMENTATION CONTROL FACILITIES, MEASURES AND STRUCTURES. ADDITIONAL FACILITIES, MEASURES AND STRUCTURES MUST BE INSTALLED WHERE NECESSARY TO COMPLY WITH ALL APPLICABLE CODES AND STANDARDS AND/OR TO PREVENT ANY, INCLUDING THE INCIDENTAL DISCHARGE OF SILT -LADEN RUNOFF FROM EXITING THE SITE. 13. THE CONTRACTOR MUST PROTECT ALL EXISTING TREES AND SHRUBS. THE CONTRACTOR MUST REFER TO THE LANDSCAPE AND/OR DEMOLITION PLAN(S) FOR TREE PROTECTION, FENCE LOCATIONS AND DETAILS. 14. THE CONTRACTOR MUST REFER TO GRADING PLANS FOR ADDITIONAL INFORMATION. 15. THE CONTRACTOR MUST CLEAN EXISTING AND PROPOSED DRAINAGE STRUCTURES AND INTERCONNECTING PIPES ON OR OFF -SITE AS THE JURISDICTIONAL AGENCY REQUIRES, BOTH AT THE TIME OF SITE STABILIZATION AND AT END OF PROJECT. 16. SOIL EROSION CONTROL MEASURES MUST BE ADJUSTED OR RELOCATED BY THE CONTRACTOR AS IDENTIFIED DURING SITE OBSERVATION IN ORDER TO MAINTAIN THE COMPLETE EFFECTIVENESS OF ALL CONTROL MEASURES. 17. THE CONTRACTOR MUST IDENTIFY, ON THE PLAN, THE LOCATION OF WASTE CONTAINERS, FUEL STORAGE TANKS, CONCRETE WASHOUT AREAS AND ANY OTHER LOCATIONS WHERE HAZARDOUS MATERIALS ARE STORED. DRAINAGaE AND lLOI`I]IoITY NOTES (Rev.1/2019) 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 2. LOCATIONS OF ALL EXISTING AND PROPOSED SERVICES ARE APPROXIMATE, AND THE CONTRACTOR MUST INDEPENDENTLY VERIFY AND CONFIRM THOSE LOCATIONS AND SERVICES WITH LOCAL UTILITY COMPANIES PRIOR TO COMMENCING ANY CONSTRUCTION OR EXCAVATION. THE CONTRACTOR MUST INDEPENDENTLY VERIFY AND CONFIRM ALL SANITARY CONNECTION POINTS AND ALL OTHER UTILITY SERVICE CONNECTION POINTS IN THE FIELD, PRIOR TO COMMENCING NY CONSTRUCTION. THE CONTRACTOR MUST REPORT ALL DISCREPANCIES, ERRORS AND OMISSIONS IN WRITING, TO THE ENGINEER OF RECORD. 3. THE CONTRACTOR MUST VERTICALLY AND HORIZONTALLY LOCATE ALL UTILITIES AND SERVICES INCLUDING, BUT NOT LIMITED TO, GAS, WATER, ELECTRIC, SANITARY AND STORM, TELEPHONE, CABLE, FIBER OPTIC CABLE, ETC. WITHIN THE LIMITS OF DISTURBANCE OR WORK SPACE, WHICHEVER IS GREATER. THE CONTRACTOR MUST USE, REFER TO, AND COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE UTILITY NOTIFICATION SYSTEM TO LOCATE ALL OF THE UNDERGROUND UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ALL DAMAGE TO ANY EXISTING UTILITIES WHICH OCCUR DURING CONSTRUCTION, AT NO COST TO THE OWNER AND AT CONTRACTOR'S SOLE COST AND EXPENSE. THE CONTRACTOR MUST BEAR ALL COSTS ASSOCIATED WITH DAMAGE TO ANY EXISTING UTILITIES WHICH OCCURS DURING CONSTRUCTION. 4. THE CONTRACTOR MUST FIELD VERIFY THE PROPOSED INTERFACE POINTS (CROSSINGS) WITH EXISTING UNDERGROUND UTILITIES BY USING A TEST PIT TO CONFIRM EXACT DEPTH, PRIOR TO COMMENCEMENT OF CONSTRUCTION. 5. STORMWATER ROOF DRAIN LOCATIONS ARE BASED ON ARCHITECTURAL PLANS. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING LOCATIONS OF SAME BASED UPON FINAL ARCHITECTURAL PLANS.E 6. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING SITE PLAN DOCUMENTS AND ARCHITECTURAL PLANS FOR EXACT BUILDING UTILITY CONNECTION LOCATIONS, GREASE TRAP REQUIREMENTS AND DETAILS, DOOR ACCESS, AND EXTERIOR GRADING. THE ARCHITECT WILL DETERMINE THE UTILITY SERVICE SIZES. THE CONTRACTOR MUST COORDINATE INSTALLATION OF UTILITY SERVICES WITH THE INDIVIDUAL COMPANIES, TO AVOID CONFLICTS AND TO ENSURE THAT PROPER DEPTHS ARE ACHIEVED. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT INSTALLATION OF ALL IMPROVEMENTS COMPLIES WITH ALL UTILITY REQUIREMENTS OF THE APPLICABLE JURISDICTION AND REGULATORY AGENCIES AND ALL OTHER APPLICABLE REQUIREMENTS, RULES, STATUTES, LAWS, ORDINANCES AND CODES AND, FURTHER, IS RESPONSIBLE FOR COORDINATING THE UTILITY TIE-INS/CONNECTIONS PRIOR TO CONNECTING TO THE EXISTING UTILITY/SERVICE. WHERE A CONFLICT(S) EXISTS BETWEEN THESE DOCUMENTS AND THE ARCHITECTURAL PLANS, OR WHERE ARCHITECTURAL PLAN UTILITY CONNECTION POINTS DIFFER, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IN WRITING, AND PRIOR TO CONSTRUCTION, MUST RESOLVE SAME. 7. ALL FILL, COMPACTION, AND BACKFILL MATERIALS REQUIRED FOR UTILITY INSTALLATION MUST BE EXACTLY AS PER THE RECOMMENDATIONS PROVIDED IN THE GEOTECHNICAL REPORT AND THE CONTRACTOR MUST COORDINATE SAME WITH THE APPLICABLE UTILITY COMPANY SPECIFICATIONS. WHEN THE PROJECT DOES NOT HAVE GEOTECHNICAL RECOMMENDATIONS, FILL AND COMPACTION MUST, AT A MINIMUM, COMPLY WITH THE STATE DOT REQUIREMENTS AND SPECIFICATIONS AND CONSULTANT HAS NO LIABILITY OR RESPONSIBILITY FOR OR AS RELATED TO FILL, COMPACTION AND BACKFILL. 8. DURING THE INSTALLATION OF SANITARY, STORM, AND ALL UTILITIES, THE CONTRACTOR MUST MAINTAIN A CONTEMPORANEOUS AND THOROUGH RECORD OF CONSTRUCTION TO IDENTIFY THE AS -INSTALLED LOCATIONS OF ALL UNDERGROUND INFRASTRUCTURE. THE CONTRACTOR MUST CAREFULLY NOTE ANY INSTALLATIONS THAT DEVIATE, IN ANY RESPECT, FROM THE INFORMATION CONTAINED IN THESE PLANS. THIS RECORD MUST BE KEPT ON A CLEAN COPY OF THE SITE PLAN, WHICH THE CONTRACTOR MUST PROMPTLY PROVIDE TO THE OWNER IMMEDIATELY UPON THE COMPLETION OF WORK. 9. THE CONTRACTOR MUST ENSURE THAT ALL UTILITY TRENCHES LOCATED IN EXISTING PAVED ROADWAYS INCLUDING SANITARY, WATER AND STORM SYSTEMS, ARE REPAIRED IN ACCORDANCE WITH REFERENCED MUNICIPAL, COUNTY AND OR STATE DOT DETAILS AS APPLICABLE. THE CONTRACTOR MUST COORDINATE INSPECTION AND APPROVAL OF COMPLETED WORK WITH THE AGENCY WITH JURISDICTION OVER SAME. 10. FINAL LOCATIONS OF PROPOSED UTILITY POLES, AND/ OR POLES TO BE RELOCATED ARE AT THE SOLE DISCRETION OF THE RESPECTIVE UTILITY COMPANY, REGARDLESS OF WHAT THIS PLAN DEPICTS. 11. WATER SERVICE MATERIALS, BURIAL DEPTH, AND COVER REQUIREMENTS MUST BE SPECIFIED BY THE LOCAL UTILITY COMPANY. THE CONTRACTOR MUST CONTACT THE APPLICABLE MUNICIPALITY TO CONFIRM THE PROPER WATER METER AND VAULT, PRIOR TO COMMENCING CONSTRUCTION. REV DATE COMMENT BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: CAD I.D.: NCC18211OSDO PROJECT: ARKA H EIGHTS I'� ARKA �H[�EIGHTS, L� LOCATION O]F SIT E 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY Op D �M D O O ]EkY�IIIY]EIEIk�IIiY� 13C, ]�ILILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC )30hlerEng.com � 0 -� o000000 i o° °o � o oFESS /�°°,° o° °o o �` o o ® - ��oo�tiGINE�o .�� i °oo oo° ✓� 00000 ///i��� o F� \ \ \ �2 �9 �� SHEET TITLE: SHEET NUMBER: C-1®2 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211OSDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:54 PM LAST SAVED BY: MMOORE H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110SDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:54 PM LAST SAVED BY: MMOORE 0 47jr.. 1-- N-1 1) TOTAL AREA: 10.400 ACRES 2) AREAS COMPUTED BY COORDINATE METHOD. PROPERTY LINE 3) PROPERTY SHOWN HEREON IS SUBJECT TO ALL RIGHTS -OF -WAY, EASEMENTS AND RESTRICTIONS OF RECORD. 4) ALL DISTANCES SHOWN ON SURVEY ARE HORIZONTAL GROUND DISTANCES UNLESS OTHERWISE NOTED. -- ADJOINER LINE 5) ALL PROPERTY CORNERS WERE FOUND TO BE MONUMENTED AS NOTED __..._._.__.__ _.____._—_,___ RIGHT-OF-WAY LINE 6) THIS SURVEY DOES NOT REPRESENT A TITLE SEARCH BY THIS FIRM. `, _ _ — _ _ _ TIE LINE 7) RIGHTS -OF -WAY INFORMATION IS APPROXIMATED BY DEEDS AND PLATS OF RECORDS. 8) NO NORTH CAROLINA GEODETIC SURVEY MONUMENT WAS FOUND TO EXIST WITHIN 2000' OF THE SUBJECT TRACT. TREE LINE N.C. GRID COORDINATES SHOWN ARE REFERENCED TO NC GRID NAD'83-NSRS 2011, AND ESTABLISHED VIA THE IRON ROD SET NORTH CAROLINA VIRTUAL REFERENCE SYSTEM. O FOUND MONUMENT (AS DESCRIBED) 9) BASIS OF BEARING SHOWN HEREON IS A BOUNDARY SURVEY PREPARED BY S.M. SANDY SURVEYING, DATED 3/26/17. 10) THE PROPERTY SHOWN HEREON IS LOCATED IN FLOOD ZONE "ZONE X", AREA OF MINIMAL FLOODING, PER FLOOD '2� 0 �� COMPUTED POINT INSURANCE RATE MAP 3710541700J, PANEL 5417, EFFECTIVE DATE OCTOBER 16, 2008. UTILITY POLE 11) THE PROPERTY IS ZONED R-4 CZ BY THE CITY OF MONROE. �sp'o0. FIRE HYDRANT 12) PARCEL IDENTIFICATION NUMBERS AND ZONING INFORMATION SHOW UNION COUNTY GIS. (�so, 0 WATER METER 13) WETLANDS AND TOPOGRAPHIC FEATURES ARE NOT ADDRESSED ON THIS PLAT. 14) FIELD EVIDENCE SHOWN HEREON WAS TAKEN FROM AN ACTUAL FIELD SURVEY CONDUCTED ON JULY BENCHMARK 22, 2019 AND REFLECTS THE VISIBLE CONDITIONS EXISTING AT THAT TIME ONLY. DB 4223, PG 248 DB 7288, PG 554 BOUNDARY SURVEY PREPARED BY S.M. SANDY SURVEYING, DATED 3/26/17 Ix I Jr- __-_-------------.--- .__"-_------_`\ / _ --___ \ - - - - - - N/F BOREN CLAY PRODUCTS, CO. TAX 1D.' 09-363-024 DB. 2072, PG. 309 CONCRETE N53013'22"W MONUMENT 208.43' (tie) (BROKEN) I I N/F DA 40 P. HUDSON G/NA L. HUDSON TAX /0.• 09-366-020A DB. 2072 PG. 309 N/F BOREN CLAY PRODUCTS, CO. TAX /D.• 09-363-024 DB. 2072, PG. 309 N/F I SOREN CLAY I PRODUCTS, CO. 1 TAX 1D.• 09-366-001 QQ 2072, PG. 309 rr ---------- N53°1124 W 919.83' ____..__. - J co ----74.07' (tie) ----------------- / •'H. --`---- -_ --- (SR-1009 — 60 PUBLIC R/rY� �� �- PKfvL -------- -' I IN ------ ---------------- - J- - C�.S _ _ 1 INV.- ____ --- — ____ ---- --� • � �_ ,- _ --- INV.- 4 - 3 MARKER- NIF N/F ! 1 ® TAX /D.• 09-366-154 TAX lD.• 09-366-02OF RIM-663.35 RIM=656.65 I DI INV. INDI656.87 INV. OUT=660.79 INV. =661.INV. OUT=656.66 I i I t� o-�o--� k� 1 1 CAlRpl - SEAL - L-4202 °941 SURN�yo°° �� I lit SURVEYOR CERTIFICATION I CERTIFY THAT THIS MAP WAS DRAWN UNDER MY SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION (DEED DESCRIPTION RECORDED IN BOOK 7288 PAGE 554; THAT THE BOUNDARIES NOT SURVEYED ARE INDICATED AS DRAWN FROM RECORDED INFORMATION AS NOTED; THAT THE RATIO OF PRECISION OR POSITIONAL ACCURACY IS +1:10,000; AND THAT THIS MAP MEETS THE REQUIREMENTS OF THE STANDARDS OF PRACTICE FOR LAND SURVEYING IN NORTH CAROLINA (21 NCAC 56. 1600). THIS 11th DAY OF DECEMBER, 2019. LOCATION MAP NOT TO SCALE N/F BOREN CLAY PRODUCTS, CO. TAX ID.- 09-363-001 DB. 2072, PG. 309 50' 25' 0' 50' 1"=50' CARY H.WATTS I NCPLS L-4202--/ cwatts@bohlereng.com AZ-'/l•Iq DATE 20" CDR 15" DAK 16" OAK 430 15" OAK NIF 13" OAK BOREN CLAY PRODUCTS, CO. 433 TAX 10.• 09-363-024 20" CDR D8. 2072, PG. 309 434- 15" OAK 19" CDR 436 19" OAK 20" OAK 438 20" CDR N53°13'22"W M 208.43' (tie) 15" MAPLE EX. WELD I I , I , I , I , I , 443 20" OAK (TBR) I ' I r` N/F 442 DAWD P. HUDSON 18'" OAK (TBR) GINA L. HUDSON I i` TAX 1D.• 09-366-020A ¢¢¢ I �� DB. 2072, PG. 309 42" OAK (TBR) 454 ;I r 15" OAK (TBR) 455 28" OAK 456, 18"' PINE INV.=666.73 _ INV= 667.14� 1 ; `418 15" OAK / �419 N/F BOREN CLAY PRODUCTS, CO. TAX 1D.• 09-363-024 DB. 2072, PG. 309 403 404 32 "' OAK I 15" OAK _ 424 422 18" OAK 18"'C0R 19DAK ` \ 32" OAK 402 -660-�K-- `` " � ,- l � ,_ , — \ �` — 660� ' 20" OAK \ 401 - 1¢'OAK \ TOWN OF INDAN TRAIL C6\400 ` _ 18" PINE CONCRETE S52°16'20"E 956.78' ` - 01 (Zr - \ 0 00� Oat 00� 0 00 `�' '� 0 1 \ ` MONUMENT pOl . OOl �1 OOl OOI� 00 � _ \ , �\ \ OOI� 00 66 OOIT—OOl 0 OOl 397 10'BUFFER '-_- ,T-------��--- - >- - - - - \20"CDR — — — — —\ — — — — T — — — — — — — — — — — — — — ' ` I 'N'O25 REAR — — — — — — — i , 13K OAK i �V` I \` ` \ ■ ■ ■ % ■ ■ ■ ■ �`---------------- _-,-,__,- ' PINE 415 414 �� • • \ • • ♦ `\ ■ I 394 12" MAPLE TBR) 13 , • , , • ♦ / `. . 18" OAK(TBR) - • , ■ • ♦ ` 664-------- I 15" CDR 20" MAPLE fTBR)'' �'� • • _ , ■ ■ `� % I I 398 I`\ I ■ /, �� \`` ��■■�■■�• \ �14"OAK oI \ i \ , \ \ ■ I I /,i GUM I �� I ■ 1 \ I ,V N/F I `� ` ■ ; ; \ \ ; \ 80REN CLAY I ' ` ' ' �s ■ / I I PRODUCTS" CO. �`\ ; 1 I /� ma`s■ — _ _ _ I I o TAX 1D.• 09-366-001 DB. 2072, PG. 309 \ I \ , 662 I I ,� I \ ~, I ■ 1 3 C�mB 12 DA16" 6A ` ` ■ o392 / RARXETTESTflRE, X J.Z-_�----------- 18» CDR I J TA� 09 366 `-- 020j `666------------- l 25" OAK DR 7288, PC 554,- 389 .' � I \ 66h flTA,' 10 404CRES■ / , 18" OAK q \ \ _ ♦ -LESS RIGI7T ' FTVA Y 0 633 ACRES RES l 194 OAK 1 G-sB I�` `\ • • _ ■ • `---`--------------------- / S 1` 22 ` \\ / � 22" OAK � y� I I \1 ■■0000 I 16"OAK I V ■ ----- 87 601 OAK TBR - 666 ---'--------- - --- - Y 14" Ql 14 OAK I 386 ' \ It \ _ _ — / 602 \IN \ \ I \�\ \` ■ 22" OAK P \ t \ 28" DAK (TBR) S� 983 41 \ / \\ \ 13" OAK I 382 `�` o ♦ 42" OAK(TBR) / ; �\ ` 1 16" OAK 45 49 \ / / x30" I \ \\ -'\1\ ROO I I 380 \♦ 12" OAK()FR) 18" OAK(TBR) / ; ; R4GE 41 `� \J` 9" OAK (TBR) 377 CI 21 " OAK 47 / i i UILD C�(TBR S SSA o, 18" OAK(TBR) I 381 `��` --ice • \ \ \ ` 17" OAK(TBR)��� ✓ i �\ �5/ \ I _ / \ I " 25" OAK ` 46 �\ 48 - i -S �\r CI o 378 t`. \v+\\ 16" DAK „ OAK(TBR) I '01 `.6� 6� �- .\ l`,� I 14" OAK \ I F54736" y9`\, � 1 379 I I EX. POLE (TBR) 1 STORY �\� i ;g-,� .7 22" OAK I I 15" OAK 421 423 16" MAPLE 21 " MAPLE 417 416 420 412 426 425 22" OAK 17" OAK 21 " OAK 18" OAK 13" CDR 13" CDR 411 -3R ON All---- --- -------EY_POL�` ---- �l 24 RCP- `------- -------''"EX. WV . i \ EX. EDGE OF PAVEMENT 410 409 14" OAK 25" OAK 408 22" OAK 407 18" OAK 406 � FRAME I \ �� i N I EX �;A �o� RESIDENCE 40" OAK()BR) (TBR) / I L NES 5�0 5 9�S / / \ \ ✓ 665 I I 51 I I (TBR); �\ x` ' 38 i9 OAK TBR I I �j CO/YCRE7F a, 42" OAK(BR) , � .. \'a. � 20" MAPLE (TBR) \ I . • \•.. • ► •'` -S .fb I I I PROP. RAN VINE . _ --- /` •, .•'.' , t p _ 0 SETBACK' I 30'x40' `� I 20' SETF-$ -�- -------------------------- ---, T-STORE---I--�,-•s- - - . ------------------------- . ;r. �• ��• fib v� STORAGE-�I �I -I ---1ST9R�--_I l°+�•-:ti, f4,:'... ►':• �1, —` 2, �T�: y i��,\ :.,�<►. Sb�----�--I ------- ---- - - `-\-----/-\- -�----- ----------LXOLBUILDING�UDlG 452 -----664 ------ (T80 INV=662.60(TBR) 42"OAK(TBREXFH I -EXW tPOLE W,J Jo E. POLE \ EX.�..---R;,.__g_� ___.�J►_-r�-�'__- _ - - - _ _0 _ ' OH E D, �vp TE PHON7'666 � µ/ 0 µ/ µ/ W - - �7'- --�- - �.�=�� ��� _ ___ � �� - LOD W ' �� .., ''�•� .••.�..►, • w _ . �.►' '••' 'i G - - n/nwe /nrii/rn o" •n •rrn," / WW ---- _ _ -----667 _ FERMi4fA 7-=-�e�'Bif- --- WC��----�_==_�' : .. , .- :' _ - 664 — I I EX._IELE----- ---'`- --OLD CHARLOTTE V V o —'1- ---- 66� - �l _ 919.83' - a�€M€aEOD LOD LOD _-LF}D' I�t LOD -" N53p44'24" 4-----____ --- (SR-1009 — 60 PUBLIC R/W) ' --------- ------ -- II --------- -------------1 _ ------------ ---------------------- --- ------------ 666 ------------ -- - - -_- _ I 1 _ — I _-- 65 - - - i-- 665--�` SEX. POLE EX. EDGE OF 66 1. 69 665 N/F PAVEMENT TAX 1D.• 09-366-020F FUTURE 8'" WATER MAIN (BY OTHERS, SEE PLANS PREPARED BY KENNEY DESIGN GROUP, P.A. TITLED HARKEY CREEK PHASE 2" I I I I I � I I I DEMOLITION LEGEND EXISTING NOTE TYPICAL NOTE TEXT DEMOLITION NOTE EASEMENT LINE - - CONCRETE CURB & GUTTER - FENCE -X----X----X---- UTILITY POLE PPca.) LPCQ> LIGHT POLE LPC_Q) ry UNDERGROUND WATER LINE —w ---- _G UNDERGROUND GAS LINE -G----G-- —OH— OVERHEAD WIRE --GW----GW-- ® TELEPHONE BOX R - STORM SEWER _ SANITARY SEWER MAIN HYDRANT SANITARY MANHOLE G ® STORM MANHOLE 0 ® STORM INLET t HEADWALL WELL LOCATION L 1 ® M WATER METER ®WM E© ELECTRIC METER r GAS METER WOODS \ - N/F RIM=663.35 TAX ID.- 09-366-154 /NV 1N=661.12 DI lNV OUT=660.79 R1M=656.65 s lNV 1N=656.87 \ lNV OUT=656.66 \s Sv-vn/Y(/V/YLV V � W W 07'05�€------------------------- ``-- -"-- --- ----74 0Z' (tigj----------------------------------- I PK NAIL ---- — ---- --------------------------------------------- ------ FUT1/R 6""HAATER MAIN ---------, CONCRETE 'BY OTHERS; 5E£ PLANS -------------------------------- MONUMENT WRE-13�BY KENNEY DESIGN N.•472, 698.127 GROUP, P.A. TITLED "HARKEY E.•1,5123,72.804 CREEK PHASE 2" EX. CIL CURRENTLY EX. PROPERTY LINE ACTING AS PROPERTY I LINE. SEE SITE PLAN I FOR ROW DEDICATION DETAILS I 1 DEMO NOTES. 1. EXISTING RESIDENCE, WELL AND ON -SITE 1 WASTEWATER DISPOSAL SYSTEM IS TO BE 1 DEMOLISHED/ABANDONED PRIOR TO SITE DEVELOPMENT. ANY ADDITIONAL WELLS OR ON -SITE WASTEWATER DISPOSAL SYSTEMS DISCOVERED DURING CONSTRUCTION WILL BE ABANDONED IN ACCORDANCE WITH APPLICABLE NC LAWS AND RULES AFTER CONTACTING UNION COUNTY I ENVIRONMENTAL HEALTH TO OBTAIN I NECESSARY PERMITS. 2. SEE LANDSCAPE PLANS FOR TREE PRESERVATION CALCULATIONS LEGEND TREE PROTECTION FENCING LIMITS OF DISTURBANCE LOD LOD 40 20 10 0 40 1 "= 40' 01 REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=40' CAD I.D.: NCC18211OSSO PROJECT: ARKA HEIGHTS FOR ARKA HEIGHTS, LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)3ohlerEng.com SHEET TITLE: EXISTING CONDITIONS & DEMOLITION PLAN SHEET NUMBER H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110SS0.DWG PRINTED BY: MMOORE 12.16.19 @ 5:55 PM LAST SAVED BY: MMOORE H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110SSO.DWG PRINTED BY: SFARMARTINO 12.17.19 @ 8:18 AM LAST SAVED BY: MMOORE 2" ASPHALT SURFACE COURSE (S 9.513) 0 1.5" ASPHALT SURFACE COURSE (S 9.5B) TRUNCATED DOME PATTERN 1.5" ASPHALT BINDER COURSE (S 9.5B) EDGE OF CURB MAX 2% IN ANY DIRECTION d AT LANDING a e " COMPACTED STONE BASE e ° d " e d ' 8" COMPACTED STONE BASE ° d' n < ° ° n < ° n SLOPE �QA e .1 2:1 MAX:, a d . .a 12:1 MAX..*. a n. AX ° d b �T4 44 (� 4 0000000000000000 e 00$$$$$$°000 °. d n° a, . ' ' $LO 2 n e° a w ° 00000000 000000000 e° � 00000000 00000000o n' !��'d d 4 ® m —1 1=III=III=III=III=III=III=III=III=III=III=III=III=III=III=III=III=III I-1 1=III=III=III=III=III=III=III=III=III=III=III=III=III=III=III=III=III TRUNCATED MAX o -I I �—III—� I I=1 I I=III III=III=� I I=1 11— 11—I I I-1 I I-III=III=III=III=1 I I—� -I I �—III—� I I=1 I I-1 I �=III=III=� I I=1 11—I I I —I I I-1 I I-III=III=III=III=1 I I—� DOME PATTERN ®� g z w m ;m III—III—III=1 �'- 1:12 SLOPE C� � � � � ® � N COMPACTED SUBGRADE COMPACTED SUBGRADE FLUSH CURB ® g o (PER GEOTECHNICAL REPORT) (PER GEOTECHNICAL REPORT) 5'-0'I SEE SITE PLAN a FOR DIMENSION NOTE. MIN. P F� NOTE. NOTE. 44 44 o z 1. SECTION SHOWN PER GEOTECHNICAL REPORT PREPARED BY CESI, ENTITLED SUPPLEMENTAL GEOTECHNICAL ENGINEERING EVALUATION, DATED 11/14/2019 ADA ACCESSIBLE RAMP CONSTRUCTION SHALL CONFORM TO CURRENT ADA 1. ADA ACCESSIBLE RAMP CONSTRUCTION SHALL CONFORM TO CURRENT g (PROJECT #190512.000). FINAL DESIGN TO BE PROVIDED ONCE FINAL CBR'S ARE ACCESSIBLE GUIDELINES. ADA ACCESSIBLE GUIDELINES. AVAILABLE ON COMPACTED SUB -BASE. N o 0 HEAVY DUTY ASPHALT PAVEMENT SECTION STANDARD DUTY ASPHALT PAVEMENT SECTION ADA ACCESSIBLE RAMP DETAIL ADA ACCESSIBLE RAMP DETAIL NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE REVISIONS REV DATE COMMENT BY PAVEMENT DIMENSIONS ON PLAN VIEW PAVEMENT DIMENSIONS ON PLAN REFER TO FACE OF CURB VIEW REFER TO FACE OF CURB 12" Z-O" Z-O" REFLECTIVE ALUMINUM CONCRETE PAVEMENT SECTION LEGEND AND BORDER - GREEN 6" 1" 6" RESERVED WHITE SYMBOL ON BLUE BACKGROUND PARKING BACKGROUND - WHITE TYPICAL AT ALL ADA SPACES PAVEMENT SURFACE TACK COAT (SEE PAVEMENT DETAIL) (APPLIED AT A RATE OF 0.2 GALLONS/S.Y.) r 1-1/2"R 1-1/2"R THIS SIGN TYPICAL AT ALL "VAN ACCESSIBLE" PARKING SPACES A a; .. .: ... ;fir+. :.�.:�.. ��«.. '• .j•� .1.�., •?. ACCESSIBLE PENALTY SIGN WITH WORDING AS SPILL CURB & GUTTER COLLECTOR CURB & GUTTER REQUIRED BY STATE OR LOCAL LAW NOTES. 1. CONCRETE FOR CURBING SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 P.S.I. @ 28 DAYS. 2. CONSTRUCTION STAKING FOR CURB INSTALLATION SHALL BE REFERENCED (CUT OR FILL) TO THE TOP OF CURB. 3. AT CONTRACTOR'S OPTION, THE GUTTER THICKNESS MAY BE INCREASED AT THE EDGE OF PAVEMENT TO MAKE BOTTOM OF GUTTER CONTIGUOUS WITH BOTTOM OF ASPHALT PAVEMENT. GALVANIZED "U" CHANNEL POST KNOW WHAT'S BELOW 4. CONTRACTION JOINTS SHALL BE PLACED @ 10'-0" O.C. TOOLED 1/4" (t1/16") WIDE, 1" DEEP. EXPANSION JOINTS SHALL BE PLACED @ 40'-0" INTERVALS, MAXIMUM, AND ALL P.C.'S. ALWAYS CALL 811 5. GUTTER PAN SLOPE TO BE ADJUSTED WITHIN ACCESSIBLE PARKING SPACES TO MATCH SLOPE BETWEEN SPOT ELEVATIONS. LL 2 � 4" DIA. SCH. 40 GALVANIZED STEEL PIPE BEFORE YOU DIG o BOLLARD PAINTED OSHA YELLOW FILLED It's fast. It's free. It's the law. 00, I WITH CONCRETE CONCRETE -TO -ASP -ASPHALT DETAIL CONCRETE CURB & �GlL7�I`T ER D E�I`AIL o � l NOT APPROVED FOR NOT TO SCALE NOT TO SCALE o CONSTRUCTION o w m P PAINT CONCRETE BLACK AFTER r� 0 CURING AT ASPHALT LOCATIONS PROJECT No.: NCC182110 2' MIN. CLEAR ZONE I DRAWN BY: SOM (TYP., LT. & RT.) 6 CHECKED BY: SRF 6666 4000 PSI CONCRETE DATE: 12/11/2019 j SCALE: 1 "=60' U CAD I.D.: NCC18211OSDO EX. CONC. PROP. CONC. VARIES PAVEMENT PAVEMENT 6" CONCRETE 4" COMPACTED STONE BASE °• D PROJECT: ° 2% MAX. CROSS SLOPE i' ARKA P EPDXY DOWEL @ 18ATED 0 C. 6x6 WWM (10 GA.) °V ° HEIGHTS P—III=III=III :.,.: � :'.:: ;t: �' - ::':':::.j:-<.:•::.'::.::..:,::'.:<.::. +.: ,.:'�:;..'., �'::'. I I=III=III= .....-....: .. ............... .. _, .......; ....:.....: :.:.... , ..,...::.::.., .. _ _ _ _— — — — — — — — — = o .�. _III —III —III —I III —III —III— I — — — —' EXPANSION JOINT MATERIAL :'t. ;-;.:•,<:,••::.,:;;..-'' :,.. ,, :...... ,, f :..,.......::. ...:, .. — — — — — — _ _ _ _ _ _ _ __ I—III—III=III I I—III—III-1 GROUT -I 11=1 11=1 11 -1 1=III=III=III=III=III—III=III=III=III III IIII—III r ,:: III=III=III=III=III ° III=III=III=III=III=III=III=III=III ARKA HEIGHTS _-_ =' ' ` r� ' ' �` ` ' III III III III III III —III —III —III —III —III —I I I� III —III —III —III —III —_III , _ 4" CLASS A CONCRETE —III—III-III—III III III —III -III —I I —III—III— LL(� —1 I -- .. I I, ; I I 1=I 1 I=I 1 I=I 1 I, ;III III —III —III —III —III I I 1=1 11=1 11=1 11=1 11=1 11=1 11=1 I I 111-111—III_ II=1II—III—III—III—I ° p __— COMPACTED SUBGRADE (PER (300o P.S.I. @ z8 DAYS) — — — — — — — — — — — — — — — — — —_ _ =I I I —I I I —I I I —I I 4" -11II I _ I11=1 11=1 1,I11I COMPACTED SUBGRADE I—II—=III=III= III_=III 1IIIII— GEOTECHNICAL REPORT) THICK, COMPACTED (PER GEOTECHNICAL REPORT) III I I =II=III II_=1IIIII_=1IIIII_=1IIIII_=1IIIII_=1IIIII_=1IIIII_— 1II 11=1 I i STONE BASE (TYPE 2a) I I=III—I I —III —III —III —III —I I —I I I —I I I —I I I—III—III=III LOCATION OF SITE NOTE. =III III —III —III —III —III III—III—III—III=III= —I I=1 I1=1 I1=1 I1=1 I1=1 I =1 I1=1 I1=1 I I— 4610 OLD CHARLOTTE HIGHWAY NOTE. 1. SECTION SHOWN PER GEOTECHNICAL REPORT PREPARED BY CESI, ENTITLED MONROE, NC 28110 NOTE. 1. CONTRACTOR TO BLOWOUT DUST FROM DRILLED HOLES PRIOR TO APPLYING SUPPLEMENTAL GEOTECHNICAL ENGINEERING EVALUATION, DATED 11/14/2019 1'-6" 1. EXPANSION JOINTS 1/2" WIDE PREMOLDED BIT. MATERIAL SHALL BE INSTALLED GROUT. (PROJECT #190512.000). FINAL DESIGN TO BE PROVIDED ONCE FINAL CBR'S ARE UNION COUNTY AVAILABLE ON COMPACTED SUB -BASE. AT 30' INTERVALS, CRACK CONTROL JOINTS TO BE SPACED AT INTERVALS EQUAL®��° TO SIDEWALK WIDTH. ONE AT EACH ADA SPACE. WHERE ADA SPACES FACE EACH OTHER WITHOUT WALKWAY, THERE SHALL BE ONE POST WITH SIGNS MOUNTED BOTH SIDES 0 00 � ��� CONCRETE SIDEWALK DETAIL CONCRETE DOWELING DETAIL STANDARD DUTY CONCRETE SECTION BOLLARD MOUNTED ADA PARKING SIGN DETAIL ENGINEERING NC, PLLC NCBELS P-1132 NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 CONCRETE FILL TO BE ROUNDED Fax: (980) 272-3401 FOR PROPER RUN OFF NC@BohlerEng.com PAVED SURFACE/ CONC. PAD--,,,. 6" CONCRETE 8" COMPACTED STONE BASE 3' TAPER _45 ' CURB 3' TAPER 4" DIAMETER STEEL PIPE FILLED �\\\ �y BREAK W/ CONCRETE PAINTED TRAFFIC `�\ oFESS /�° [-6x6 WWM (10 GA.) YELLOW AND EMBEDDED IN _ ° ° '�y°° CONCRETE BASE - v = o - - GUTTER PANo 'g' ,a 0 ;., FULL HEIGHT CURB P OF ASPHALT OR 1" RADIUS CONCRETE SLAB L °°°NG I NE�o ° 3' RIP -RAP PAD �° FN __ _____ ___ __ 2 I=I I I=I I I=I I I=I I I=1 I I=1 I I=1 I I=1 I I=1 11=III=III=III=1 11=III=III=III=III=III= ���� i=I I=I I=I I t I I=I I=ITI- I �� II I I, ;III-1 I I-1 I I, ;III ;IIII ; ,III-1 I —III—III—III IIII-11III111III11 (IIII I I-1 STD. CURB (PER SITE PLAN) 3000 P.S.I. CONCRETE I I —III —III —I III —III= _— I I=III f,' I I —III —I SHEET TITLE: � I —I-- '. III —_III: COMPACTED SUBGRADE _ _ o 1" RADIUS (PER GEOTECHNICAL REPORT)T —III — III —I I ` I I —III— - PAVEMENT SURFACE III—III—_ III —I : ;;' ..° III—_ I � II M I —I I I —I I I —I I I. ': I I —I I I= I —III —I I I —I I I" x°: > I I —I I I 3' TAPER BREAK 3' TAPER =III —III —III —I ". s' . III= ���� ������� —I I I —I I I —I I I _ III=1 I -I I = I., I I I I I I-1 I I-1 I I 1 JEL EVATION NOT Ev 1. SEE SITE PLAN FOR LOCATION(S). SHEET NUMBER:MIN. C-302 HEAVY DUTY CONCRETE SECTION CURB ]BREAK DETAIL CURB TAPER DETAIL BOLLARD DETAIL NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211OSDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:55 PM LAST SAVED BY: MMOORE H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110GPO.DWG PRINTED BY: MMOO RE 12.16.19 @ 5:56 PM LAST SAVED BY: MMOO RE v v ra H � 1G7 ' Z 7D 000 �Om:0cn mz =� =mODDm Z rn Z ='60m H r 0 0 H nD>> r 0 ` O z SHEET 1 OF 2 840.03 43" NOTE: USE TYPE "E", "F" AND "G" GRATE UNLESS OTHERWISE NOTED. PLAN FRAME,GRATE, & HOOD ASS'Y SECTION - AA 1�6 11 rr p� rr --IF-- .syl1- - Lx 31/2 6 3' 0„ 6rr 3rr SECTION - KK ALIGN FRAME"EN EDGE OF WAL FOR VERTICA SECTION - BB � rnnnlc r�r4n 3' - 0?'8" R c� NT T r� 2h" II SECTION - LL T SECTION - PP I Err 2r-0" Err O J��"" _ 2'-111/2" R HOOD ELEVATION z 00 H- Q PI P z�=ci H " 0=02 I LL H- C. 21) J L.�" N- N H2r ZW (n H- LL 0 SECTION - NWI O Q Z 11Q d IJJ T T SECTION - NN 4" \I t�_ Ji- IN; n O Q CO _ = 0 = i rr 1Z1 Q U H 01 Q U c\ N 0= W U Q ~ z Q SECTION - JJ ft O 5�/8" SW _ J fn C7 3rr R z LL LL v 1/2 SECTION - RR SHEET 1 OF 2 840.03 1L MANHOLE E D F <- ,- ` D ¢�H AID CZ,ma ).54 Ci FOR MANHOLE COVER & FRAME P LANOPTIONAL SPACED 6" C. TO C. BRICK MAY BE USED TO ADJUST FRAME & COVER TO SURFACE ELEVATION MAX. 1' OUTLET PIPE E OR F 1%2" T A 1 INLET PIPE SECTION C-C OR D-D SECTION X-X �c 6" 1j" X 6" EXP. JOINT 9" 6" a i - B 3 B. 6 SEE NOTE 3 DOWEL SECTION Y-Y Y PLAN WITH GRATE & FRAME REMOVED SECTION X-X GENERAL NOTES: CHAMFER ALL EXPOSED CORNERS 1" USE CLASS "B" CONCRETE THROUGHOUT. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS TO CONSTRUCT THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF BOX, ADD TO BASE AS SHOWN ON STANDARD NO. 840.00. PROVIDE ALL JUNCTION BOXES OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTERS IN ACCORDANCE WITH STD. NO. 840.66. ADJUST THE STEEL, CONCRETE AND BRICK MASONRY QUANTITIES TO INCLUDE THE ADDITION OF THE MANHOLE (I.E. DIAGONAL BARS SHORTENED AROUND OPENING IN TOP SLAB, ADDITIONAL VARIABLE HEIGHT BRICK MASONRY, OPENING IN TOP SLAB.) MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP ELEVATION IS 12 FEET. T #4 BAR NIT DOWEL DIMENSIONS AND QUANTITIES FOR CONCRETE JUNCTION BOXES DIMENSIONS OF BOX AND PIPE REINFORCEMENT BARS "A" TOP SLAB DIMENSIONS CUBIC YARDS IN BOX TOTAL QUANTITIES BOX AND SLABS DEDUCTIONS FOR ONE PIPE CU. PIPE SPAN WIDTH HEIGHT D A B H N0. LENGTH E F TOP SLAB BOTTOM SLAB WALL/ FT, OF HT. LBS. REIN'F CU. YDS. MIN. "H" C.S. R. C. 12" 2'-0" 2'-0" 2'-3" 12 2'-9" T-0" T-0" 0.167 0.167 0.185 22 0.750 0.015 0.024 1.5 2'-3" 2'-3" 2'-6" 12 3' 0" 3'-3" 3'-3" 0.196 0.196 0.204 24 0.902 0.023 0.036 18" 2'-6" 2'-6" 2'-9" 14 3'-3" 3'-6" 3'-6" 0.227 0.227 0.222 1 30 1.065 1 0.033 0.049 24" 3'-0" 3'-0" 3'-3" 16 3'-9" 4'-0" 4'-0" 0.296 0.296 0.259 40 1.434 0.059 0.085 30" 3'-6" 3'-6" 3'-9" 18 4'-3" 4'-6" 4'-6" 0.375 0.375 0.296 51 1.860 0.092 0.127 36" 4'-0" 4'-0" 4'-3" 20 4'-9" 5'-0" 5'-0" 0.463 0.463 0.333 64 2.341 0.132 0.178 42" 4'-6" 4'-6" 4'-9" 22 5'-3" 5'-6" 5'-6" 0.560 0.560 0.370 77 2.878 0.180 0.243 48" 5'-4" 5'-4" 5'-3" 26 6'-3" 6'-4" 6'-4" 0.743 0.743 0.407 111 3.623 0.235 0.317 54" 5'-10" 5'-10" 5'-9" 28 W-7" 6'-10" 6'-10" 0.865 0.B65 0.444 126 4.283 0.297 0.401 60" 6'-6" 6'-6" 6'-3" 30 7'-3" 7'-6" 7'-6" 1.042 1.042 0.481 145 5.090 0.367 0.495 66" 7'-1" 7'-1" 6'-9" 32 7'-10" 8'-1" 8'-1" 1.210 1.210 O'5111 169 5.917 0.444 0.589 WEEP HOLES GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL DROP INLETS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR 2" KEYWAY OR #4 BAR DOWELS AT X 12" CENTERS AS DIRECTED BY THE ENGINEER. - USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. CONSTRUCT WITH PIPE CROWNS MATCHING. SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES NOT SHOWN. INSTALL 2" WEEPHOLES AS DIRECTED BY THE ENGINEER. INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF NO. 78M STONE IN A POROUS FABRIC BAG OR WRAP, AT EACH WEEP HOLE OR AS DIRECTED BY THE ENGINEER CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. .Vr 1IVU I IIAU1U[IN 1HL) )P ELEVATION 840.16 FRAME - RATE (SEE NOTE) MAX. PIPE THIS SIDE SECTION Y-Y DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX & PIPE CUBIC YARDS CONC. IN BOX DEDUCTIONS FOR ONE PIPE PIPE SPAN WIDTH MIN. HEIGHT D A B H BOTTOM SLAB WALL PER FT. HT. cONGRiE -MINIMUM HEIGHT, H C.M. R. C. 12" 3'-0" 2'-0" 2'-0" 0.222 0.222 0.592 0.015 0.026 15" 2'-3" 0.648 0.023 0.036 181, 2'-6" 0.703 0.033 0.049 24" 3'-0" 0.814 0.059 0.085 30" 3'-0" 2'-0" 3'-6" 0.222 0.222 0.925 0.092 0.127 #4 BAR N s" DOWEL z 00 <Q Q Fz-1 LL J0H O O x Z W QZLLx Q 0 = O H H- U) LL 0 _j o ocf)a Z jr, H 1 W 0 o X LL O - 0 CO LLI O z H Q I..I < d o Q _ Q J (0 = z Q (o z o O CC < W o U) LLJ r jy H p z Q O V cr 840.31 Z 00 �Q Q FZ-I CC 0 . ILL J 0 _L o Cn x LL1Q Z ULx QU�01�- H- (/)HLLOJ oo�Q Z FH 1 �~ Win O LL W (D J H Z W EL H o_ a o 0 co < C Qcr � 0 z W x � H (n W _ y cc N � z T �O O c> 840.14 GENERAL NOTES 2'-0D W T As z o� �� �> < � USE 4000 PSI MINIMUM COMPRESSIVE STRENGTH CONCRETE. INTERNAL MIN. MIN. MIN. CIRCUMFERENTIAL F- < 1 Z CONCENTRIC Q Q F- Cn O FABRICATE, ASSEMBLE AND DESIGN PRECAST MANHOLE COMPONENTS DIAMETER WALL TOP/BOTTOM AREA OF STEEL Q D H O CONE SECTION I- U) ACCORDANCE WITH AASHTO M199. (FT.) THICKNESS SLAB THICKNESS PER VERTICAL FT. FZ-I CC C-) H Z = D ASSEMBLE RISER AND GRADE RINGS WITH THE STEPS SPACED 12" (IN.) (IN.) (SO. IN.) WO 0 = Z = O m n m FROM THE TOP TO THE BOTTOM OF THE MANHOLE. W Q Z LL ^ m O WHERE THE MANHOLE IS EXPOSED TO ROAD TRAFFIC, CONSTRUCT 4 4 6 0.12 Q U O N Z x -0 O m THE TOP OF THE MANHOLE FLUSH WITH THE GROUND AND A MINIMUM 5 5 8 0.15 H = Z W 0 0 �r-I OF 9" ABOVE THE GROUND AT OTHER LOCATIONS. 6 6 8 0.18 Cn ~ U O J [[ H n = � Z LIMIT DEPTH OF FILL TO 30'-0" FROM FINISH GRADE TO TOP OF 0 O CD CC D BOTTOM SLAB. D Z Cn H r THE IN. SLAB THICKNESS 'T' IS THE DIMENSION OF THE r IL 0 Z THINNEST PORTION OF THE TOP/BOTTOM SLAB. ALTERNATE CONE SECTION 2�- ` W N GRADE RING �� T 0 * TOP MAT OF REINFORCEMENT MAY BE NEGLECTED IF TOP SLAB HAS MIN. AREA OF STEEL A DISTINGUISHABLE TOP AND BOTTOM. ° IS 0.07 in.2 ECCENTRIC CONE m'D'+2'W' W C7 ADDITIONAL 6" MAX. SPACING L u 1" MIN. OF CIRCUM. R/F D CLR. #4 REBAR LOCATE WALL REINFORCEMENT CO IN MIDDLE THIRD OF WALL o m .•.;,. n .• ;;.: e: 2 Q Z 1" MIN. O Be O CLR. USE MIN. AREA OF STEEL IN TOP n• LL r SLAB OF #4'S @ B" CTS. STEP STD. _ Z 0 EACHWAY/EACH FACE *. NO. 840.66 Z N 0 x FLAT TOP SLAB As (CIRCUMFERENTIAL ~' G O- r Z cn FRAME AND GRATES BTD. NO. REINFORCEMENT) Q H m TRAFFIC BEARING 840.37 a = Z ADDITIONAL #4 EACH LONGITUDINAL -Phv SIDE OF OPENING (1" NONTRAFFIC BEARING: 840.22 ADDITIONAL #4 EACH REINFORCEMENT O LL) co C D CLEAR OF BOTTOM FACE 140.24 SIDE OF OPENING (1" RISER *' PLACE BARS DIAGONAL 640. 00 CLEAR OF BOTTOM FACE) "_ OD O TO CORNERS (TYP. ) 640.29 Z v 840.33 = DD - - - rWr 'DI 'W' J ~ FRAME & GRATE i ` O m _ SEE STD. 840.54 = = r Z 7 _ _ _ _ _ X r i �X FOR MANHOLE BASE RING AND COVER z J O I- - JL =-II I l 1 � . r c J _IL _ ;I I ; t k]e)�j �� REINFORCED CONC. W \ �--JL--11 r 1 1 �(� - e, e, ...e,. -FIG. (SEE STD. `-y r 7 .:io• ..•y':s'w :•: ;s':rr :•.•r;:io'':.•c 1525.01 IF N m X \ , _ - r I USE MIN. AREA OF STEEL REQUIRED) Q I \ ♦ 7 - I IN BASE SLAB OF Lu m `` ir' ``� ice' ILu ------FOOT EACH12 in PER LINEAR - - - - - - , _ d TYPICAL MANHOLE SECTION SHEET 1 of 1 GRATED INLET OPTION MANHOLE OPTION SHEET 1 of 1 840.52 840.52 .. 1" MIN. CLR.(TYP) ; •' •v 4x4 W4xW4 :q WWF (LAP WWF 6" ON- TO FABRIC) o• v GENERAL NOTES: Z O THIS PRECAST BOX MAY BE USED FOR THE FOLLOWING STANDARDS: H �f �r"•4� =6- �f �� 840.04, 840.05, 840.14, 840.15, 840.31, 840.32, 840.34, 840.35, 840.36 AND 840.41. QQ Z < 1" MIN. {•�=a V * INSTALL AND PAY FOR PRECAST DRAINAGE STRUCTURES IN ACCORDANCE H 0 C3 CLR. TYP ( ) SECTION VIEWS WITH NCDOT STANDARD SPECIFICATION SECTION 840. WO _J a = z * USE 4000 PSI MINIMUM COMPRESSIVE STRENGTH CONCRETE. 2 Z OPTIONAL JOINT DETAILS * USE ASTM A615 GRADE 60 REINFORCING STEEL. USE ASTM A185 U WELDED WIRE FABRIC (WWF). O Q #5 REBARS @ 12" * LIMIT MAXIMUM DEPTH TO TOP OF BOTTOM SLAB TO 15'-0". F- F_W CENTERS (HORIZ. & VERT.) * PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH OSHA STANDARD 1926.704. cr LLC,1--1 Q O Coo) cr (USE WITH * ORIENT STRUCTURES SO THAT CORNERS WILL NOT BE CUT OR MODIFIED Z • j 4' X 4' & LARGER UNLESS ALLOWED BY DETAIL IN PLANS. N (L H DRAINAGE STRUCTURES * PRECAST ALL ELEMENTS TO MEET ASTM C913. T W 0 TYPICAL) - 'L' BARS WITH * FRAME AND GRATE HEIGHT MAY BE ADJUSTED WITH CONCRETE 1'-6" LEGS OR BRICK IN ACCORDANCE WITH STANDARD 840.25. PLAN VIEW OF BASE UNIT * PROVIDE PRECAST STRUCTURES OVER 4'-0" IN DEPTH WITH STEPS 12" ON CENTERS IN ACCORDANCE WITH STD. NO. 840.66. 6" L' OR 'W' fi" * WELDED WIRE FABRIC MAY BE SUBSTITUTED FOR REBAR IF MIN. MIN. THE SAME MIN. AREA OF STEEL IS PROVIDED. * SEAL JOINTS WITH AN APPROVED SEALANT (SEE SECTION 840 OF NGDOT i co* STANDARD SPECIFICATIONS. #4 REBARS @ LIMIT MAXIMUM STRUCTURE SIZE INSIDE CLEAR DIMENSIONS #4 REBARS @ 6" CENTERS m TO 6'-0" X 6'-0". :i) EACHWAYITE '°: EACH WAY * THE OUTSIDE PIPE DIAMETER PLUS 2" IS THE MINIMUM STRUCTURE LL a W IN SIZE OR THE OPENING REQUIRED FOR GRATE AND FRAME WHICHEVER 0 'o CENTEROTHIRD TYPICAL PRECAST IS GREATER. W OF WALL ROUND MANHOLE MAY BE USED IN LIEU OF SQUARE PROVIDED 2 EXTRA ,Zy RISER SECTION #5'S ARE PLACED ON EVERY SIDE NOT ADJACENT TO A WALL. SEE STD. 3 d DWG. 840.34 FOR MANHOLE INSTALLATION. c 0 m > y PRECAST RISER PLANcc N y m v 2 #5 BARS EACH SIDE O Q z OF OPENING FULL SPAN _ .Z4 6" L' 6" Z W W Cv 1" MIN. CLEAR 'O MIN. MIN. H m Q O m cn I L' OR 'W' + 2 WALLS " S N a z o, 1 MIN. CLR. O C m I 64 CENTERS W_ �,,, .�. H LL O STEPS m m I¢ REBAR ro 4x4 W4xW4 J o v' .o' „ c7 a 0 a O I 3 o WWF ( LAP WWF CO D' O' D' Z 6" ONTO FABRIC) C H CID D ' .. •.Q. Q: 0 ' W I- R - - - - - - - - - OPENING1 "@ #5 REBARS 12" CLEAR (SEE NOTES) CENTERS LOCATE OPENING Z TYPICAL SECTION •' :_°' �/°' AS REQUIRED m (SEE NOTES) TOP SLAB Z of 1 6" 'L' 6" TYPICAL SECTION .46 MI"' PLAN TOP SLAB MIN. OF BASE UNIT v m H Z D H o DETAIL SHOWING TYPES OF GRATES USE ACCORDING TO WATER FLOW. 2` 113/" 2 rr 1 1/22 "� z 0 Cn >` Q Q Z < U mZm=� B CD �JIL OOmC-) = m z m0 n rr n r rr TYPE G TYPE E TYPE F A A 1 rr� I 9/8" O O O S WQZW ^ F_ U m o H Z o m \v cT ��LL0 J v z D y D �- WATER FLOW -� �- SAG WATER FLOW -•- T T I9 Z IEEEH H 2E 1 B �2 1 4 rr CL ' 0 - - - - - - - - - - - - - - - - - - - - - - - H ih rrrr ���"� SECTION B-B O-n ----------------------------•------ 1 rr 21/4" I m z WATER FLOW SAG �- WATER FLOW �- 1�- G~ O O Q LL cn r SECTION A -A = m r"mc~n z = TYPE "F11 TYPE "E,, TYPE "G" TYPE - E z = Z cn A Z Q Q Q 9 RAISED FLOW ARROW D z y Q. RAISED FLOW ARROW 2 3" 1s HIGH 2�'1 Imo- Q N a N vv %s" HIGH -� QD Q W 0 0 � z v� O Q O 1 rr Q =cn � > Z 1 rr _m \ I z O v Z = 0 D TO 1 it O '//] a ♦✓ T 1 ig rr CRC 13/" Y cl) W W C��S O Q' 1Y2 rr 1�rr 1�2rrR f01 z 11/2n 1n l 2'-113/4r 11/2rr 11/2''1f /grr T 2'-113/41r �grr 1�2n W 0 LL SECTION A -A =LL81%2"13/4 SECTION A A SHEET 2 OF 2 SHEET 2 OF 2 840.03 840.03 v v m H � 1 1' Z 70000 r O TIRO 1_4 --Am:D =0Zym =Cn00 O m �DDD In 0 o Z � m 0 Z O 0 z H j OCD = N m =mZ c C) D � -1v D F•-I cL _v W H m N z O H m z p BACK OF CURB - r-m► X PLAN X SECTION Y-Y RISER HT. VARIES A _ - 0 6" 0 'o WHERE 30" TO 36" PIPE IS USED RISER HT. VARIES - - - - PA 0 WHERE 42" TO 54" PIPE IS USED DETAIL SHOWING METHOD OF RISER CONSTRUCTION Y SECTION X-X GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL CATCH BASINS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. USE TYPE "E", "F" AND "G" GRATES UNLESS OTHERWISE INDICATED. FOR 8'-0" IN HEIGHT OR LESS USE 6" WALLS AND BOTTOM SLAB. OVER 8'-0' TO 16'-0" IN HEIGHT USE B" WALLS AND BOTTOM SLAB. ADJUST QUANTITIES ACCORDINGLY. CONSTRUCT WITH PIPE CROWNS MATCHING. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. 6„ 6" D vb EC " T SECTIONv J-J WHERE 30" TO 36" PIPE IS USED SEE NOTE L PLAN WHERE 42" TO 54" PIPE IS USED J A A a, of o PLAN Z 00 Q Q H2=C.) LL J a 1 Z o0Ux ccLu Z H-0cc0 H ►-1 c)HLLOJ 0OCDQ Z 1 ,1­4 9� �0 Q o Z LL m 0 CA Z CC M c = 0- 0 z cr o LO Qcc W = H-H� In UJ N U) r H z J O 0 V Z W 0 [� f o0 Q OLT 44 O 44 �o cQ - `w Pf) o 44 g � m 44 oz u" a w pp w P4 U - PH �oC -- �LL o o REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD 1. D.: NCC182110GPO PROJECT: AKA HEIGHTS FOR ARKA HEIGHTS LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY 0 00 L �TE I 11INGIIN EEKING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)3ohlerEng.com rSHEET TITLE: S7["ORMWA7["E1I� DETAILS SHEET NUMBER: C-402 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110GPO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:56 PM LAST SAVED BY: MMOORE TRENCH WIDTH _ I I TRENCH III WIDTH _ -III -I GRADE 111� _ I _ -III I I III7 M I II -I1 I- I= -I I I -I I z FF I I� -ICI w W �18 -III III IIIII IIII O IIIII 0 �I-IIII �J a III _-III 6' I I I III a e a a 12" -III I 1 I -I a '��°. O-RING a . . 6" 24°. " RCP I ' e =III I II -I ° I 116 -III ANTI -SEEP -I I III n I II ° a ° ° II I I COLLAR I D_' I I d: 'a .. I I d da d ° 12" -III I I ANTI -SEEP COLLAR. I= CLASS B CONCRETE OR III- I i COMPACTED CLAY WITH I- INFILTRATION RATE OF 0.01 INCHES PER HOUR OR LESS. SECTION A -A ANTI -SEEP COLLAR NTS SCREW TYPE PLUG 6" 4" PVC PIPE AND TEE 'PERMANENT POOL 61 BOHLER ENGINEERING DETAIL PVC CAP WITH 2.0" HOLE DRILLED PER WATER QUALITY ORIFICE SIZE LISTED FOR WET POND NOTES: 1. DRAW DOWN ASSEMBLY SHALL NOT BE INSTALLED UNTIL WET DETENTION BASIN IS STABILIZED. DRAWDOWN ASSEMBLY NOT TO SCALE BOHLER ENGINEERING DETAIL TEMPORARY SEDIMENT CLEANOUT ELEV. = 659.00' INFLOW �i BOTTOM OF TEMPORARY SKIMMER BASIN = 658.00' (SEE EROSION CONTROL PLANS) 3:1 SIDE SLOPES SEDIMENT CLEANOUT ELEV. 657.00'--/ BOTTOM OF POND ELEV. 656 - L 100-YEAR STORM EVENT @ ELEVATION 662.79' V 25-YEAR STORM EVENT @ ELEVATION 662.34' L 2-YEAR STORM EVENT @ ELEVATION 661.11' TEMPORARY POOL (1" WQV) @ ELEVATION 659.47' L PERMANENT POOL @ ELEVATION 659.00' CLASS 1, 15" THICK RIP -RAP BERM CREST ELEV. = 658.50' PUMP TO DRAIN IF NECESSARY FOR POND MAINTENANCE MENT CLEANOUT ELEV. 657.00' BOTTOM OF POND ELEV. 656.00' GENERAL NOTES: WHET POND I (WEST) CIROSS 1. SEE WET POND PLANTING PLAN FOR LANDSCAPING REQUIREMENTS SECTION 2. POND TO BE LINED WITH COMPACTED CLAY WITH INFILTRATION RATE OF 0.01 INCHES PER HOUR OR LESS NTS (10:1 VERTICAL EXAGGERATION) FABRICATED ALUMINUM BAR C GRATE TRASH RACK WITH TOP OF POND ELEV. 664.00' 5"X5"OPENINGS - - - - - - - - - - TOP OF RISER ELEV.661.50' 24"X12" RECTANGULAR WEIR ELEV. 659.75' 24"X12" RECTANGULAR WEIR ELEV. 659.75 4' X 4' BOX STRUCTURE (INTERNAL DIMS) 24" OUTLET CULVERT ELEV. 659.00' PERMANENT POOL ELEV. 659.00' 2" ORIFICE CONNECTED TO ----NOTES: o 1 � 1 l� 1 ' 1 1 g 1, 1 DRAWDOWN ASSEMBLY SEE NCDOT STANDARDS FOR 24" OUTLET CULVERT ELEV.659.00' OUTLET STRUCTURE BOX, GRATE, ELEV. 659.00' REINFORCING, ETC. 2"ORIFICE CONNECTED TO 5'X5'X1.5' CONCRETE BALLAST PAID -,"""" AD ALL CONCRETE TO BE 3,600 PSI DRAWDOWN ASSEMBLY ' (INCLUDING PRECAST BOX WALLS COMPRESSIVE STRENGTH. ELEV. 659.00' ' X AND BOTTOM SLAB, FILL BOTTOM i O OF STRUCTURE TO 1.5' BELOW OUTLET CULVERT WITH CONCRETE AND PROVIDE SMOOTH FINISH AT INVERT OF STRUCTURE) / 1 WHET POND I RISER STRUCTURE NTS Tnn nr I-1nAIr% rl r\ / P-PT A nnI WET POND I SPILLWAY DETAIL NTS TOP OF POND ELEV. 664.00' 40' WIDE CIPOLETTI SPILLWAY ELEV. LINED WITH 18" THICK CLASS 1 R MAX 3:1 SLOPES FOR TEMPO DRAWDOWN PIPE 3:1 SLOPES UNDER PERMANENT POOL A-EP G 664.30 0 X ` TC 665.88 BC 665.38 L ���-- co co I il TC 666.09 664.97 TC 666.47 BC 665.97 70 o� OUTFLOW / `t-ANTI-SEEP COLLARS �6' WIDE, 6:1 VEGETATED SHELF AFTER STABILIZATION BUT PRIOR TO PAVING, POND TO BE DREDGED AND CONVERTED FROM SKIMMER SEDIMENT BASIN TO PERMANENT WET POND. CONTRACTOR TO PUMP/DREDGE BASIN ONLY IF TOP OF SEDIMENT STORAGE ELEVATION IS ABOVE 660.00'. ---------- T -T L -L -L -L -L i LP 664.87 101 REVISIONS REV DATE T COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. A-1.1 111.70'- 2 4" RCP @ 0.60% NOT APPROVED FOR P HCONSTRUCTION EQUILIBRIUM PIPE CONNECTION POND 1 AND POND 2 PROJECT No.: NCC182110 I I 348.14' DRAWN BY: SOM /�?n-7 I-18" RCP @ 0.00% CHECKED BY: SRF lim DATE: 12/11 /2019 SCALE: 1..=60' CAD I.D.: NCC18211OGPO D TC 666.53 D D TC 666.2 ` BC 666.03 1 BC 665.7 TC 665.90 e BC 665.40 D ° TC 666. � BC 666. e D F F D G 666.50 1M eD LL 5. T -1D - D O� LTEH TC 665.ENGINEERING NC, P LILC e BC 665.24 4 NCBELS P-1132 TC 665.74�J��OP� BC 665.24 66A' ° G 666.01 gg5 G 665.14 ; a; G 665.57 I oo� I o°I G 665.36 � Ga � G 666.28 z r ±'F 666.50 ®R (2) 30 15 7.5 0 30 1..= 30' 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)3ohlerEng.com SHEET TITLE: BOND DETAILS SHEET NUMBER: C-403 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110GPO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:56 PM LAST SAVED BY: MMOORE H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110GPO.DWG PRINTED BY: MMOO RE 12.16.19 @ 5:56 PM LAST SAVED BY: MMOO RE N/F BOREN CLAY PRODUCTS, CO. TAX 10- 09-363-024 DB. 2072, PG. 309 N53°13'22"W 208.43' (tie) N/F DAWD P. HUDSON GINA L. HUDSON TAX ID.• 09-366-020A DB. 2072, PG. 309 INV.=666.73 INV= 667.14 MONUMENT EX. POLES 24" RCP W W W I PROR TRASH ENCLOSURE (BY OTHERS) 1 1 0 1 i PROP. DRAINAGE--/ FLUME PRIVATE 6" PVC FIRE LINE M , O K 00 N � I v ? z 0 r I ' PROP. DRAINAGE) FLUME \ CmB 90° BE RCP u_ N/F BOREN CLAY PRODUCTS, CO. TAX 1D.• 09-363-024 DB. 2072, PG. 309 TOWN OF INDIAN TRAIL �! • 16f ■ PROR TRASH ENCLOSURE (BY OTHERS) 18" RCP rmn /011 .l•b• APPROX. ADA • r NIT LOCATION APPROX. ADA BUILDING BUILDING 3 .4. UNIT LOCATION +/-16,300 +I 16,300 SF 44 UNITS* ADA) 45 UNITS (3 ADA) , F PRIVATE 4" PVC 69 DS APPROX. ADA 69 BEDS DOMESTIC LINE FF f67.17 UNIT LOCATION FFE: 667.17 y .'. PROP. SAN CLEANOUT (TYP.) I F `I U r PRIVATE 6" g0° BEND II BATH PVC FIRE LINE F PROP. FDC �cA CONNECTION GSB PROP. SAN II 45' BEND (TYP.) CLEANOUT (TYP.) PRIVATE 4" PVC DOMESTIC LINE CLUBHOUSE 110 +/-6 000 SF b. 18" RCP `o,• • �� III � � rT a N �• a I b PRIVATE 4" PVC DOMESTIC LINE PROP. SAN BUILDING 4 CLEANOUT (TYP.) +/-15,800 SF 44 UNITS (2 ADA) APPROX. ADA 64 BEDS UNIT LOCATION FFE: 666.17 f: }i 0 \�^- 7■ ■ ♦♦ I ■ I ■ ■ I ■ PROP. DRAINAGE ■ FLUME win_ I ': ; . ' : i.:" FFE. 667.5 ` PROP. 4"4" TEE.' - $ •: °'::. .:.: y.. 6 t " .. . b . . T A. APPROX.ADA ' 18" RCP I UNIT LOCATION P" 45° BEND I. 24 RCP PRIVATE 8 PVC FIRE LIE - r PROP. 6"X6" TEE 24" RCP ♦ SAN + . SAN qAKI 18" RCP - 3 MH8 MH7 MH4 M 3 MH2 -- �� . 85.23 - 8" S S 35 @ 1.00% 85.23 - 8" SAN SDR-35 @ 0.50% 85.16 - E " SA SDR-35 @ 0.50% , 90' BEND J II .' b IS ' - }. • 18+ .29 18+0 o G9 .' O\o '� 0 13+50 13+0 2+50' O r 4. b S' �� J L L a U O b sO�3s 0 � o o ♦ '�.. BUILDING 1 „5Q o .�... ♦ ! +/-15,700SF b'. -- .4. •' ` s, :' �o 45' BEND �� �a �. b. __ +. •�RRE 4•. b.• _ b.. 39 UNITS ADA) ( ) > x o �fv1Hs SAN ca.. � -. o b t' 66 BEDS s T 20 SDR-35 @ 0.50% MH5 ♦ , FFE: PROP.FIRE , b..' HYDRANTLOCATION.:. o ♦ HYDRANT LOCATION 16+50 16+0 15+50 15+00 PRIVATE 6" ; .. APPROX. ADA M APPROX. ADA o o t, APPROKADA � PVC FIRE LINE UNIT LOCATION UNIT LOCATION ao U N I LOCATION ♦ ♦ s: 18" RCP 181 nR� 18"RCP ...:.. PRIVATE 4" PVC BUILDING 5 ' PROP. FDIC BUILDING 6 PROP. 4"X4" TEE ': • DOME STIC L N E I +I-10,000 SF ` CONNECTION CONN +/ g 800 SF - - rn W L W L b. :.: . , PROP. 6 X6" TEE.:'.. • ,.: :;b. '• - '• _ .. b i... b ..: PROP. FDC 24 UNITS (1 ADA) 45 BEDS (TYP.)E 24 UNITS (1 ADA) APPROX. ADA F F r CONNECTION b 42 BEDS �* UNIT LOCATION M M M M M ' M FFE: 668.17 AT FFE:667.17 0 4.1 INSET F F F F F b; 45° BEND PUBLIC UTILITY IMPROVMENTS PROPOSED MA HOLE LI r� o 1 o PROP. RIW LINE INCLUDE 6" PVT LATERAL 0 6, -� 10 b FUTURE 8" WATER e S N W PROP. PU LIC 20' SEWER EASEMENT LINE BY OTHERS :. O'X10 15.2' BORE PI b T EX. ELE BOX 4, .. . . .. :: :. .. ..... . .. .... , .. .. ULL .b . . #F ND EX. POLE 6NV w Ex E WV EX. WM PROP PROPERTY LIN EX. POLE INV.=662.60 N EX. EDGE OF PAVEMENT SEX. POLE INV = EX. EDGE OF 661.69 TAX ID.• 09/366-020F PAVEMENT �8" WdT (BY nr�SEE Pi GAS I PREPARED BY KENNEY DESIGN GROUP, P.A. TITLED HARKEY CREEK PHASE 2" INSET PROP. PRIVATE 8" PVC FIRE LINE PROP. PRIVATE 4" PVC DOMESTIC LINE PROP. FIRE VAULT D D U- D. A PROP. 2" IRRIGATION I POOL SERVICE LINE PROP. 4" DOMESTIC METER (TO BE INSTALLED AFTER FIRST BUILDING PERMIT IS PULLED) 90° BEND LL PROP. 4"X2" TEE --- - -PROP. 4"X8" TEE - OH-OH- Of - OH � 8" WATER LINE BY OTHERS W -W W W W 8" TEE; CONTRACTOR TO REPLACE 8" WATERLINE TO MANUFACTURE JOINTS 10 5 2.5 0 10 1"=10' H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110UPO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:57 PM LAST SAVED BY: RBRELAND I I 1 I I 1 I I I I I I I I I I I UTILITY SERVICE INFORMATION ESTIMATED WATER CONSUMPTION (DWELLING): 400 GAUDAY PER DWELLING UNIT MIN. 400 GAUDAY PER UNIT x 211 MAX UNITS = 84,400 GAL/DAY MAX NUMBER AND SIZE OF METERS: 1 - 3" DOMESTIC METER (360 GPM) 1 - 2" POOL & IRRIGATION METER IRRIGATION: ASSUMED 16,000 GAUDAY FOR TOTAL SITE DURING SUMMER MONTHS SWIMMING POOL: MIN. 10 GAUDAY PER PERSON X 300 PERSONS = 3,000 GAUDAY. FIRE FLOW: ASSUMED 1000 GPM FOR HYDRANT (3 PROPOSED). WASTWATER FLOW RATES: 140 GAL/DAY x (69) 1 BEDROOM UNITS = 9,660 GAL/DAY 140 GAL/DAY x (132) 2 BEDROOM UNITS = 18,480 GAUDAY 210 GAUDAY x (10) 3 BEDROOM UNITS = 2,100 GAL/DAY EX. POLE E _0 OH �y;; W W 18" LOD W W Wo^AB 8"ACWWATE Owl- W W- _ _ OLD CHARLOTTE HWY, N53°1124"W 919.83' OD LOD `-"LOD (SR-1009 - 60 PUBLIC R/W) o So 10'X10 X I3.T ECEIVINtiT PROP. ±50 LF JACK AND BORE FOR SAN. MAIN TO ADJACENT "HARKEY CREEK SUBDIVISION" (SEE SHEET C-501) EX. 111� ,,, FUTURE 8" WATER MAIN PAVEMENT N (BY OTHERS; SEE PLANS 6 1 DI DREPARED BY KENNEY DESIGN R1M=663.35 N/F GROUP, P.A. TITLED "HARKEY TAX ID.- 09-366-154 INV /N=661.12 Dl CREEK PHASE 2" INV DUT=660. RIM=656.65 EX. C/L CURRENTLY INV IN=656.87 ACTING AS PROPERTY 1 INV OUT=656.66 LINE. SEE SITE PLAN l ��so FOR ROW DEDICATION UTILITY NOTES. SEE SHEET C-502 �sq�so DETAILS 1. WATER LINES SHALL BE BURIED AS SPECIFIED IN UNION COUNTY STANDARD SPECIFICATIONS AND DETAILS FOR ROADS, STRUCTURES AND UTILITIES S@o (LATEST EDITION). WATER MAINS SHALL NOT BE PLACED UNDER BUILDINGS OR STRUCTURES EXCEPT TO SUPPLY A SPRINKLER SYSTEM. THE 440 MINIMUM COVER FOR WATER MAINS WITH AN 8" DIAMETER OR LESS IS 30 INCHES. IF THE MAIN EXCEEDS A 12 INCH DIAMETER, THE REQUIRED COVER / IS 36 INCHES. ALL WATER LINES TO BE DUCTILE IRON PIPE. / 2. WATER MAINS SHALL BE PLACED NO CLOSER THAN 4 FEET FROM THE BACK OF CURB TOWARD THE STREET. (4' PROPOSED) SAN 3. WATER MAINS SHALL BE LOCATED AT LEAST 10 FEET LATERALLY FROM EXISTING AND PROPOSED SANITARY SEWERS. 4 4. WHERE IT IS NECESSARY FOR WATER MAINS TO CROSS OVER SEWER MAINS, VERTICAL 18" CLEARANCE IS REQUIRED. 5. EXISTING WATER SERVICES THAT WILL NOT BE UTILIZED MUST BE TERMINATED AT THE MAIN AND REMOVED AT CORP. STOP. 6. VALVES SHALL BE INSTALLED ON ALL BRANCHES FROM FEEDER MAINS AND BETWEEN MAINS AND HYDRANTS AS FOLLOWS: 6.1. TWO (2) VALVE AT TEE INTERSECTIONS, 7. PRIVATE WATER SYSTEMS MUST HAVE SUFFICIENT VALVE PLACEMENT AND NUMBER SO THE PRIVATE SYSTEM CAN BE ISOLATED FROM A PUBLIC 1 WATER SYSTEM. 1 8. CONTACT THE ENGINEERING SERVICES DEPARTMENT, CONSTRUCTION INSPECTION DIVISION AT 864-596-2838 FOR ALL WATER AND SEWER MAIN CONSTRUCTION. ALSO ALL WATER AND SEWER SERVICE TAPS, DRIVEWAY AND SIDEWALK INSPECTIONS, STORM DRAINAGE AND ROADWAY IMPROVEMENTS. 9. QUALITY OF WASTE TO BE DELIVERED TO UCPW'S SYSTEM FOR TREATMENT DOMESTIC 10. SEWER MAIN DESIGN MUST BE LESS THAN 14' DEEP (MAX COVER) 11. FIRE HYDRANT SHALL BE PLACED A MINIMUM DISTANCE OF 6 FEET BACK OF CURB AND HAVE A CLEAR SPACE OF 3 FEET FROM ANY PERMANENT STRUCTURES. / 12. METERS WILL NOT BE SET IF WATER METER BOXES, SEWER CLEANOUTS, VALVE BOXES OR THEIR APPURTENANCES ARE DAMAGED OR IMPROPERLY POSITIONED. 13. REFER TO UNION COUNTY SPECIFICATIONS, UNION COUNTY WATER AND SEWER EXTENSION POLICY AND TO UNION COUNTY WATER SEWER MATERIAL LIST EXTENSION ORDINANCES. 14. DEWATERING: THE CONTRACTOR AT ALL TIMES SHALL PROVIDE AND MAINTAIN AMPLE MEANS AND EQUIPMENT WITH WHICH TO REMOVE AND WATER SYSTEM PROPERLY DISPOSE OF ANY AND ALL WATER ENTERING THE EXCAVATION OR OTHER PARTS OF THE WORK AND KEEP ALL EXCAVATION UNTIL SUCH g PVC PIPE (SDR 18) = 29 ± LF (PUBLIC) TINE THAT THE PIPE LAYING AND GRADING IS COMPLETED AND STRUCTURES TO BE BUILT THEREIN ARE COMPLETED. NO WATER SHALL BE ALLOWED 4" PVC PIPE (SDR 18) = 16 ± LF (PUBLIC) TO RISE AROUND THE PIPE UNTIL BACKFILL TRENCHES NOR SHALL IT BE ALLOWED TO RISE OVER MASONRY UNTIL CONCRETE OR MORTAR HAS SET 2" PVC PIPE (SDR 18) = 16 ± LF (PUBLIC) (MINIMUM OF 24 HOURS). ALL WATER PUMPED OR DRAINED FROM THE WORK SHALL BE DISPOSED OF IN SUCH A MANNER AS TO PREVENT SITUATION IRRIGATION METER VAULT = 1 AND EROSION TO ADJACENT PROPERTY OR OTHER CONSTRUCTION. DOMESTIC METER VAULT = 2 15. VERIFICATION HAS BEEN MADE BY BOHLER ENGINEERING THAT EACH MULTI -UNIT BUILDING IS CAPABLE OF HAVING GRAVITY SEWER SERVICE TO THE FIRE LINE METER VAULT = 1 IRRIGATION METER PROPOSED SEWER MAIN. 3" DOMESTIC METER = 1 16. FOR PARCELS WITH EXISTING STRUCTURES, CLEARLY IDENTIFY PREVIOUS AND EXISTING WATER AND SEWER SERVICES (WELL, SEPTIC, OR COUNTY 8" FIRE BFP = 1 WATER/SEWER) ON PLANS. IF WATER ANR/OR SEPTIC ARE EXISTING, THEN COPY TRACI COLLEY(TRACICOLLEY@UNIONCOUNTYNC.GOV) ON PLAN/REDLINES TO NOTIFY. MAKE NOTE THAT THE ENGINEER IS TO DIRECTLY CONTACT TRACI COLLEY (704-283-3717) WITH ENVIRONMENTAL HEALTH SEWER SYSTEM FOR THEIR SEQUENCE OF EVENTS AND OTHER PERTINENT INFORMATION. 17. THE WATERMAIN WILL BE RESTRAINT JOINT DIP 40 FEET BEFORE AND AFTER TO EACH FITTING. 6" PVC = 22 ± LF STUB (PUBLIC) 18. NO RECORDS OF EXISTING ON -SITE WASTEWATER DISPOSAL SYSTEMS OR WELLS ON SITE. ANY SYSTEMS FOUND TO BE ABANDONED WITH THIS 8" PVC = 11 ± LF STUB (PUBLIC) 8" DIP = 115 ± LF (PUBLIC) DEVELOPMENT IN ACCORDANCE WITH APPLICABLE NORTH CAROLINA LAWS AND RULES AFTER CONTACTING UNION COUNTY ENVIRONMENTAL 16" STEEL CASING = 50 ± LF (PUBLIC) HEALTH TO OBTAIN NECESSARY PERMITS. 48" SEWER MANHOLES (TYPE II) = 1 (PUBLIC) I I 1 1 1 CONCRETE I MONUMENT F N/F BOREN CLAY PRODUCTS, CO. TAX ID.• 09-366-001 DB. 2072, PG. 309 ;P. ASH I V SURE OTHERS) I POLE S53°07'05"E 74.07' (tie) PK /LD CHARLOTTE CONCRETE MONUMENT N.•472, 698.127 E.•1,5123,72.804 ( PROPERTY LINE ■ 40 20 10 0 40 1 "= 40' REVISIONS REV DATE 7 COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=40' CAD I.D.: NCC182110UPO PROJECT: ARKA HEIGHTS ]F0113 ARKA HEIGHTS, LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY Lj DD 0 TEIT La )1, TE� ]ENGINEERING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)30hierEng.com o oFESS /C°° o ° oo o , o 0 o °°o�NGINE�e,°° °°° °° F9 SHEET TITLE: OVERALL UTILITY PLAN SHEET NUMBER H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110UPO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:57 PM LAST SAVED BY: RBRELAND 14 GAUGE STRANDED BLUE COATED COPPER TRACER WIRE SADDLE UNION COUNTY PUBLIC WORKS DEPARTMENT UNION COUNTY, N.C. COPPER SERVICE TUBING CONNECTOR CORPORATION APPROVED SERVICE HARDWARE 2"PVC MUELLER FORD H-13420 S70 SADDLE UP TO 8" SEE NOTE FC 101 BALL CORPORATION B-25008 FB1000G YOKE H-5020 Y 502 ANGLE BALL VALVE B-24273 BA94-323WG CHECK VALVE H-14247—A HHS91-323 CONNECTORS I COPPER STYLE 110 GRIP JOINT EXPANSION CONNECTION EC 23 NOTE: ROMAC 101N SHALL REPLACE MUELLER FOR PIPE DIAMETER UP TO 8" SMITH BLAIR 317, FORD FIE 202 OR ROMAC 202N SHALL REPLACE MUELLER FOR PIPE DIA. 12" AND UP STANDARD DETAIL SERVICE CONNECT ON SCALE: N.T.S. DATE: 10-4-11 VEMEMENEX CONCRETE 4" 1/2 OF PIPE DIA. STONE CLASS A CLASS B NOTES: ALL CONCRETE = 3000 PSI ALL STONE = N.C.D.O.T. NO. 67 UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL Q SCALE UNION COUNTY, N.C. PIPE BEDDING N.T.S. U DATE: 11-17-06 WATER MAIN CR❑SSING UNDER STORM DRAIN DETAIL ONLY APPLICABLE IF MAXIMUM DEPTH OF BURY FOR WATER MAIN IS LESS THAN 6' AT CR❑SSING, PROPOSED GRADE IIIIiIIIIIIIIIIIII— IIII� I�'�1IIIIIi��IIIiIIIII, ���iII� 6,0' DEPTH (MAX.) 3.0' COVER (MIN.) STORM DRAIN 45 DEGREE 45 DEGREE I REAIhC I E3END� 12' (MIND 54' RESTRAINT J❑INT DIP RESTRAINT JOINT DIP WATER MAIN I 20' RESTRAINT J❑INT DIP 54' RESTRAINT J❑INT DIP RESTRAINT JOINT DIP UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE: UNION COUNTY, N.C. WATER MAIN UNDER STORM DRAIN CROSSING N.T.S. DATE: 31 08-31-16 NOTES: MINIMUM COVER IS 36" 2" PVC SDR 21 (200 PSI) V-8" PVC SDR 18 12" OR LARGER DIP NO STONES LARGER THAN # 67 STONE SHALL BE USED IN SELECT BACKFILL UNION COUNTY PUBLIC WORKS DEPARTMENT UNION COUNTY, N.C, TAMP IN 6" — 12" LIFT CAREFULLY COMPACTED SELECT BACK FILL 1 FT. ABOVE TOP OF PIPE HAND TAMP EARTH LJIV vv 1 I VI\ IJLLL STANDARD DETAIL WATER TRENCH NOTE: 1, MAXIMUM GROUND SLOPE OF 5' TO 1' IN ANY DIRECTI❑N INSIDE WATER/SEWER EASEMENTS, 2, SLOPE GREATER THAN 5' TO 1' MUST HAVE PRI❑R APPROVAL FROM UNI❑N COUNTY PUBLIC WORKS, FINISHED GRADE 1' VARIABLE R/W WATER OR SEWER MAIN SCALE: N.T.S. DATE: 1-14-10 NOTES: FOR PVC -- USE SDR 35 FOR 10 FT OR LESS USE SDR 26 FOR 10 FT. OR MORE. USE DUCTILE IRON - IF UNDER 3 FT DEEP OR OVER 18 FT DEEP. x NO STONES LARGER THAN # 67 STONE SHALL BE USED IN SELECT BACKFILL PVC C900 SDR 18 (200 PSII OR DUCTILE IRON CL/ WITH PROTECTEC I L —4 GRAVITY SEWER - BEDDING DETAIE CLASS C FORCE MAIN AREFULLY COMPACTED ELECT BACK FILL 1 FT. BOVE TOP OF PIPE #67STONE AMP IN -12" LIFTS :CAREFULLY COMPACTED SELECT BACK FILL 1 FT. ABOVE TOP OF PIPE HAND TAMP EARTH UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE. UNION COUNTY, N C. SEWER BEDNE DATE. BA 12-16-13 O O VITA O �0 SF vv �os"ICE PE�M\� 113mml 1 1/4' RAISED LETTERING (RECESSED FLUSH) (2) 1' (25mm) DIA. HOLES C4) 1' (25mm) DIA HOLES ON 29 3/4' (756mm) BOLT CIRCLE, 3/4' (19mm) LETTERS (RECESSED FLUSH) NOTES: 1. ALL CASTINGS TO BE FREE FROM SAND HOLES. NO PLUGGING ALLOWED. 2. MACHINE ALL CONTACT SURFACES BETWEEN RING AND COVER. 3. PROVIDE TWO VENT HOLES IN COVER, 1" DIA. TAPERED TO 1-1/8" ON REVERSE SIDE, 4. MINIMUM WEIGHTS: COVER — 120 LBS. RING — 190 LBS, S. ALL MANHOLE RINGS OUT OF ROAD RIGHT OF WAY SHALL BE BOLTED INTO MANHOLE WITH 5/8" DIAMETER KWIK BOLT STUD ANCHOR SYSTEM HILT] BRAND OR APPROVED EQUAL. BOTTOM VIEW 2' — 1 1/4" 1'— 113/4" 1'— 111/2" I 2 1/8" 4 3/8" I-- Z' — 0 1/2" 2' — 91/4" (U.S. FOUNDRY — 669, VULCAN — 1384 OR EQUAL) STANDARD DETAIL UNION COUNTY PUBLIC WORKS DEPARTMENT SCALE: UNION COUNTY, N.C. RING & COVER DATE: 9-9-11 UNION COUNTY PUBLIC WORKS DEPARTMENT MAXIMUM SLOPE ACROSS WATER/ SEWER EASEMENT SCALE: UNION COUNTY, N.C. 32 5:1 SLOPE DATE: 03/02/18 UNDISTURBED EARTH 12" L i CONCRETE _ / DITCH BANKS PLAN 45° BENDS ALSO 90°. 22 1/2°. 11 1/2° DITCH BANK H CONCRETE DITCH BOTTOM H/2 UNDISTURBED EARTH ELEVATION AT FITTINGS DITCH L BANKS MAX 45° CONCRETE UNDISTURBED EARTH DITCH BANKS PLAN TEE CONTRACTOR SHALL USE TIE RODS TO SHIM AS NECESSARY SECURE VERTICAL BENDS DITCH BOTTOM MIN. 1 1/2 CU. YD UNDISTURBED EARTH OF CONCRETE VIER I ILAL BEND UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE: UNION COUNTY, N.C. THRUST BLOCK DATE: 16 11-17-06 wa pl� a �' REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD I.D.: NCC18211OSD0 PROJECT: ARKA HEIGHTS FOR ARKA HEIGHTS, ��� LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY r D O� ��� ZNGIIN E1ERIPTG NC, P L1LC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)3ohlerEng.com �o °° oo °°° °° o oFESS /0°° 'Ly o° o , c ° o o ° o °oo �; 'L °°o�NGIN-- 000��: °°° °° FN rSHEET TITLE: UTILITY DETAILS SHEET NUMBER: C-503 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211OSDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:57 PM LAST SAVED BY: MMOORE O 1 1/4' RAISED LETTERING (RECESSED FLUSH) �,.� (2) CAM LOCKS Q� CUlAvq SEE DETAIL f J� e, I TA C38MM] _ (4) 1' (25r1r7) DIA vy ~�J "if �pv HOLES ON 29 3/4' O ® C756MM) BOLT CIRCLE. WEQ' �dJ SpACE P�-R�`��� (2) CLOSED PICKHOLES 1/2• 3/4' (19MM) LETTERS (2) CAM LOCKS 113MM3 ® (RECESSED FLUSH) BOTTOM VIEW 2'-11/4" 1' - 11 3/4" 5/8'-11 X 3 1/4' LG. 1' - 11 1/2" 1 1/2" SS PENT BOLT (2 REQ'D) 1 7/8' 5/8' SS C48MM] FLAT WASHER F3/ 7 1/2" 5/8' RUBBER WASHER 2 1/8"" 43 4' jjj 1' 10 1/4" --2' - 01/2" — 1ao'� 4 3/8" 15MM] 2' - 9 1/4" r.240' (U.S. FOUNDRY - 669, VULCAN -1384 OR EQUAL} 5/8' HEX ZNHERNYLOCK NUTUG (SHORT)NOTES: 5/8' HEX ZN1. ALL CASTINGS TO BE FREE FROM SAND HOLES. NO PLUGGING ALLOWED. JAM NUT C6MM] 2. MACHINE ALL CONTACT SURFACES BETWEEN RING AND COVER. CAM & GASKET GROOVE 3. PROVIDE 2 CLOSED PICKHOLES DETAIL 4. MINIMUM WEIGHTS: COVER - 95 LBS. RING -190 LBS. S. ALL MANHOLE RINGS OUT OF ROAD RIGHT OF WAY SHALL BE BOLTED INTO MANHOLE WITH 5/8 DIAMETER KWIK BOLT STUD ANCHOR SYSTEM, HILTI BRAND OR APPROVED EQUAL. UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE: UNION COUNTY, N.C. RING & COVER FOR SEALED MANHOLES DATE: 9A 9-2S-12 ANCHORAGE SCHEDULE 11 1/40- BEND 1 22 1/2- BEND 452 BEND 900- BEND TEE TEST PRESSURE PIPE SIZE L H L H L H L H L H (P.S.I.) 6„ 1'3" 1'0" 23" 1101, 2'6" 1'6„ 2'9" V6„ TO" 1'6" 200 V6" 1'3" 23" If' 3'0" 1'6" 4'0" 1'6" 3'0" 1'6" 300 1'6" T6„ 2'6" 1191, 3'0" TO 3'9" TO 2'6" 2'0" 200 8„ 2'0" T6" TO" 2'0" 3'9" 2'3" 4'6" 2'6" 3'6" 23" 300 2'6„ T9„ 4'0" 23 4'3" TO 5'0" 3'3" 4'0" 3'0" 200 12 3'6" 2'0" 5,3" 2,6," 6'0" 33" TO" 3'6" 5101, 3'6" 300 3'0" TO 4'0" 3'0" 4'6" 3,9„ 6'0" 3'9" 4'6" 3'6" 200 14" 4'0" 2'6" 5'3" 3'6" 6'0" 4'3" 6'6" 5'0" 5'0" 5'0" 300 16 3'0" 2'9" 4'6" 3'6" 510" 4'6" 7'0" 4'3" 510" 4'0" 200 WO" 3'0" 63" 3,9" 6'5" 53„ 8'0" 53" 7,6„ 4'0" 300 THRUST BLOCK DIMENSIONS BASED ON SOIL BEARING CAPACITY OF 2000 P.S.F. AND A WATER TEST PRESSURE OF 150 P.S.I. SIZES OF THRUST BLOCKS MAY BE REVISED BY THE ENGINEER WHERE BEARING CAPACITY OF SOIL VARIES, PROVIDE TAR PAPER JOINT BETWEEN CONCRETE THRUST BLOCK AND PORTION OF PIPE BEING ANCHORED. ALL CONCRETE THRUST BLOCKS SHALL BE 2500 P.S.I. CONCRETE, MAXIMUM VERTICAL DEFLECTION SHALL BE 22 1/2°. JOINTS SHALL REMAIN FREE OF CONCRETE FOR INSPECTION, REPAIR OR REPLACEMENT OF JOINTS. UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE: UNION COUNTY, N.C. THRUST BLOCK SPEC F CAT 0NS DATE: 11-17-06 GENERAL NOTES: 11 METER BOX LID TO HAVE AMR LOCATOR (ALLIANCE 1200 OR EQUAL FOR 50W ERT, STANDARD LID FOR 60W ERTI 21 BUILDER/PROPERTY OWNER TO INSTALL NIPPLE, VALVE AND VALVE BOX BEFORE METER WILL BE SET. 3) METER AND ERT BY UNION COUNTY P PREVAILING RATE 14 GAUGE STRANDED 8" to 10" BLUE COATED COPPER TRACER WIRE ANGLE VALVE (WITH LOCK WINGS) EXPANSION CONNECTOR 1 1/2" CLEARANCE 1, TUBING CONNECTOR ELECTRONIC RADIO TRANSMITTER VALVE BOX BY BUILDER/PROPERTY OWNER F---1 LI L I I � I I AMR METER 14 I a g iui IGI Epp � I �dh — — — — — — — —I HZmxlrL CHECK VALVE VALVE BY BUILDER/PROPERTY OWNER YOKE BRASS NIPPLE BY BUILDER/PROPERTY OWNER UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE N.T.S N.T.S. UNION COUNTY, N.C. METER INSTALLATION FOR AMR METERS 1AT146 -24"— �4 18" MAX. THREE COURSES OF GRADE RINGS MAXIMUM _ STRAIGHT WALL OF M.H. TO BE LOCATED OVER INLET �9 5' - 0" FOR PIPES _ OVER 18" 4' - 0" FOR PIPES 1R" R CMAI I FP PRECAST INVERTS ONLY 5" SCH 40 STEEL PIPE WITH EPDXY COATING RUST-OLEUM 9335 ABOVE GRADE 9578 BELOW GRADE - 9373 PRIMER T 60' 1ESH SCREEN 2" STAINLESS STEEL STAPS O.C. FROM BASE " x 3" S.S. ANCHOR PER STRAP ETE ANCHOR GENERAL NOTES: (1) 1 ROLL OF MASTIC AND A 6" EXTERNAL JOINT/SEAM WRAP INSTALLED ON EACH MANHOLE SECTION (2) MANHOLE VACUUM TESTING - AFTER EACH MANHOLE IS INSTALLED AND ALL PIPES ARE CONNECTED, BUT BEFORE BACKFILLING, THE MANHOLE SHALL BE VACUUM TESTED. ALL PIPES ENTERING THE MANHOLE SHALL BE PLUGGED AND BRACED. THE CONTRACTOR SHALL FURNISH ALL MATERALS, LABOR AND EQUIPMENT NECESSARY TO PERFORM THE TESTING. A VACUUM OF 10 INCHES OF MERCURY SHALL BE CREATED ON THE INSIDE OF THE MANHOLE. AT THE VACUUM OF 10 INCHES OF MERCURY, THE PUMP SHALL BE STOPPED AND THE TIME SHALL BE MEASURED FOR THE VACUUM TO DROP TO 9 INCHES. FAILURE OF THE TEST SHALL BE ANY AMOUNT OF TIME LESS THAN THE FOLLOWING. 4 FT. . DIAMETER MANHOLE = 60 SECONDS 5 FT. DIAMETER MANHOLE = 75 SECONDS 6 FT. DIAMETER MANHOLE = 90 SECONDS 7 FT. DIAMETER MANHOLE = 105 SECONDS 8 FT, DIAMETER MANHOLE = 120 SECONDS 10 FT. DIAMETER MANHOLE = 150 SECONDS UPON TEST FAILURE, THE CONTRACTOR SHALL REPAIR ALL LEAKS AND RETEST THE MANHOLE UNTIL THE TEST HAS PASSED. STANDARD DETAIL UNION COUNTY PUBLIC WORKS DEPARTMENT SCALE: UNION COUNTY, N.C. MANHOLE DATE:— 10 7-31-14 CONCIRETIi PAD UNION COUNTY PUBLIC WORKS DEPARTMENT UNION COUNTY, NC. VALVF BOXINSTALLATION a 1 nay n aV V41 n14 SCALE 144�11 CONCRETE RING 14 GAUGE STRANDED BLUE COATED COPPER TRACER WIRE 2" WATER MAIN J GROUND LEVEL y'\ TERMINATE 1' BELOW GROUND LEVEL VALVE BOX 2" COUPLING —VALVE BOX _2" GALVANIZED PIPE 2' LONG .a 2' GALVANIZED PIPE 3' LONG 2" - 900 BEND 2" GATE VALVE - MECHANICAL JOINT CONCRETE BLOCKING 6" PVC PIPE RESTING ON BRICK UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE: UNION COUNTY, N.C. 2" / BLOW -OFF DATE: 2 10-4-11 NOTE: A 27" DIAMETER PRE -CAST RING SHALL BE PLACED 8 3f4" AROUND EACH VALVE BOX. 7 rra' F- 2,, TOP UNION COUNTY PUBLIC WORKS DEPARTMENT UNION COUNTY, N.C. 112" 7.. �7112 BOTTOM (SCREW TYPEI STANDARD DETAIL V ALV F BOX 1/4" 1/2" 3f4" 11/2" 1" 5f16" 4" �43f4 51f2" 6 3/4" 1 1r2" COVER PAINT COLORS BODY ...... ..... ...FIRE HYDRANT RED - RUST-OLEUM ENAMEL # 1210 FIRE HYDRANT RED BONNET ........... HIGH GLOSS WHITE - RUST-OLEUM ENAMEL # 2766 CAPS.................HIGH GLOSS WHITE - RUST-OLEUM ENAMEL # 2766 HYDRANTS TO BE SET AT BURY LINE- EDGE OF R/W AT PROPERTY TO BE SET AT CORNERS EXIST GRADE LEVEL 6" MECHANICAL JOINT _ 6" DUCTILE IRON GATE VALVf BURY LEADER WITH MEGALUGS - - 14 GA. STRANDED BLUE COATED / COPPER TRACER WIRE a o N0.67 MECHANICAL JOINT WASHED rfl I "LOCKED' STONE HYDRANT TEE gti 18" x 18''6" A MINIMUM OF 6" OF CONCRETE WILL BE PLACED UNDER THE BASE STANDARD DETAIL UNION COUNTY PUBLIC WORKS DEPARTMENT ;GALE: UNION COUNTY, N.C. FRL HYDRANT INSTALLATION -a�E: CONCRETE RING �y CONCRETE RING VALVE BOX 14 GAUGE STRANDED BLUE} 2" BRASS NIPPLE - COATED COPPER TRACER WIRE 6" PVC PIPE RESTING ON BRICK WATER MAIN (SIZE VARIES) STUB LENGTH VARIES) {SEE TABLE) [SEE TABLEI GATE VALVE - MECHANICAL JOINT MJ PLUG [SIZE VARIES UPON WATERMA[N SIZE) TABLE SIZE OF PIPE LENGTH OF PIPE 6,, 40, 8" 40` 12" AND LARGER BY ENGINEER GROUND LEVEL } VALVE BOX TERMINATE T SELOW GROUND LEVEL 2" GALVANIZED 2" COUPLING - VALVE BOX PIPE 2' LONG 6" PVC PIPE RESTING ON BMCK '- 2' GALVANIZED PIPE 3` LONG 2" - 90° BEND 2" GATE VALVE - MECHANICAL JOINT CONCRETE BLOCKING UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE;. UNION COUNTY, N.C. MAINLINE FUTURE EXTFNSION WITH BLOW -OFF N.T.S. DATE: 2 A 10-4-11 wa a z C� 'T U o 4 �T4 pT4 u-) 44 (� P g a cf) P z REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1..=60' CAD I.D.: NCC18211OSDO PROJECT: ARKA HEIGHTS FOR ARKA HEIGHTS, LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY r D 0TL7 ��� ZNGIIN E1ERIPTG NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)3ohlerEng.com o°O! °o l o°o O!_ GSS /Q°Ooo o' C 'o o o ° o °�; '/L• o�NG I NEB 000 °oOoo o° >FN �2 �9 SHEET TITLE: UTILITY DETAILS SHEET NUMBER: C-504 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211OSDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:57 PM LAST SAVED BY: MMOORE NOTES: 1. NO PIPE SHALL BE SUPPORTED BY BELL. 2. END SECTIONS LESS THAN 4' MAY BE UNSUPPORTED. 3. WALL THICKNESS AS PER TABLE UNLESS OTHERWISE SHOWN ON PLAN.. 4. MASONRY SEAL AT ENDS -- 2" x 4" WEEP HOLE AT LOW END S. ALL PRESSURE PIPES TO HAVE TRACING WIRE IN ALL CASING BORES. rTrci cnirecr�ENT PIPE SPIDER SUPPORT AND SPACER AVAILABLE FROM SPIDER MANUFACTURING, INC. INSTALL PER UNION COUNTY INSPECTOR AND PER MANUFACTURERS SPECIFICATIONS. CONTRACTOR RESPONSIBLE FOR INSPECTING MATERIALS AND WELDS TO INSURE ALL SPIDERS WILL FUNCTION PROPERLY. ;PRIER PIPE CASING PIPE I.D. WALL THICKNESS „ 8" 0.188' 6" 12" 0.188" 16" 0.250" 1 " 16" 0.2j[5y0„ „ 20" 0.281 „ 1 6yp 24" 0.344" „ 30" 0.406" 30 42" 0.500" 48" 0.500" UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE: W A S E� E T N.T.S. UNION COUNTY, N.C. PIPE E DATE: 14 11-17-06 GENERAL NOTES: (1) RPDVA SHALL BE INSTALLED FOR CUSTOMER APPLICATIONS APPROVED BY UNION COUNTY PUBLIC WORKS. (2) REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION ASSEMBLY SHALL COMPLY WITH ASSE 1047 & AWWA C511(1) FEBCO 826YD, (2) WILKINS MODEL 375ADA, (3) AMES SERIES 5000 CIV. OR EQUAL (3) OWNER SHALL PROVIDE WRITTEN CERTIFICATION TO THE COUNTY THAT THE RPDVA HAS BEEN TESTED BY A CERTIFIED BACKFLOW PREVENTION TECHNICIAN AFTER INSTALLATION. (4) COUNTY APPROVED 3"-10" RPDVA INCLUDES SHUTOFF VALVES AS PART OF THE ASSEMBLY. SHUT OFF VALVES SHALL BE OS&Y RESILIENT SEAT GATE VALVES WITH HANDWHEEL OPERATORS AND SHALL CONFORM TO AWWA C500 LATEST EDITION. RPDVA SHALL BE SUPPORTED AT CENTER WITH A MASONRY PEDESTAL ADEQUATE TO MAINTAIN THE WEIGHT OF THE STRUCTURE AND PLUS AN ADDITIONAL 1,000 POUND LOAD. (5) REDUCED PRESSURE DETECTOR ASSEMBLY SHALL BE ABOVE GROUND ONLY. (6) BACKFLOW PREVENTION ASSEMBLY SHALL BE INSTALLED OUTSIDE OF THE RIGHT OF WAY, MAXIMUM OF 5 FEET. REDUCED PRESSURE PRINCIPLE BACKFLOW (7) PROPERTY OWNER SHALL BE RESPONSIBLE FOR MAINTENANCE AND OPERATION OF VARIES (SEE MANUFACT BACKFLOW ASSEMBLY AND COMPLIANCE WITH REPORTING AND TESTING REQUIREMENTS. FF (8) 3/V BYPASS DETECTOR AMR METER, ER. A »^ VOLT GFCI �RECEPTACLE� INSULATED WEATHERPROOF ENCLOSURE-------- CLASS 350 ANCHORED TO CONCRETE OR APPROVED DIP FLANG FIBERGLASS MOUNTING PAD FITTING CLEAR ADJUSTABLE PROVIDE DRAIN PORT FOR POSITIVE­--_O PIPE DRAINAGE OUT OF ENCLOSURE SUPPORT (MINIMUM TWICE THE SIZE OF RPZ) H II II III - =W— "I- 63000 PSI CONCRETE SLAB. =III GENERAL NOTES (1) RPZ SHALL BE INSTALLED FOR CUSTOMER APPLICATI❑NS APPROVED BY UNI❑N COUNTY PUBLIC WORKS. (2) REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTI❑N ASSEMBLY SHALL COMPLY WITH ASSE 1013 & AWWA C511 (FEBC❑ 825Y, WILKINS MODEL 975XL, HERSEY MODEL FRPII OR EQUAL), (3) OWNER SHALL PR❑VIDE WRITTEN CERTIFICATION TO THE COUNTY THAT THE RPZ HAS BEEN TESTED BY A CERTIFIED BACKFLOW PREVENTI❑N TECHNICIAN AFTER INSTALLATI❑N. (4) BACKFLOW PREVENTI❑N ASSEMBLY SHALL BE REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTI❑N ASSEMBLY CENTERED ON CONCRETE OR APPROVED FIBERGLASS VARIES M❑UNTING PAD AND CENTERED WITHIN ENCLOSURE, (SEE MANUFACTURER) CLASS 1 ❑R CLASS 2, ASSE �1060 INSULATED WEATHERPROOF (5) REDUCER PRESSURE ZONE ASSEMBLY SHALL BE ABOVE ENCLOSURE ANCHORED TO GROUND ONLY, CONCRETE OR APPROVED (6) BACKFLOW PREVENTI❑N ASSEMBLY SHALL BE INSTALLED A FIBERGLASS M❑UNTING PAD ❑UTSIDE OF THE RIGHT OF WAY, MAXIMUM OF 5 FEET, (7) PIPE MATERIAL SHALL BE BRASS (ASTM B43), w (8) INSTALLATI❑N SHALL BE IN C❑MPLIANCE WITH ALL APPLICABLE COUNTY ❑RDINANCES AND SPECIFICATI❑NS IN ADDITI❑N TO THE N,C, PLUMBING CODE, a 6' MIN. (9) PROPERTY OWNER SHALL BE RESP❑NSIBLE FOR z MAINTENANCE AND ❑PERATI❑N OF BACKFLOW f ASSEMBLY AND C❑MPLIANCE WITH REPORTING AND w TESTING REQUIREMENTS. LA 1' CL z Do BRASS TO METER CE THREADED UNI❑N 1'-0' MINIMUM -BALL VALVE _"� �I-77 IMINIMUMIIIII-IU I— _ I OPENING e 6' MIN 120 VOLT GFCI ELECTRICAL RECEPTACLE DRAIN PORT - PROVIDE P❑SITIVE DRAINAGE OUT OF ENCLOSURE (MINIMUM TWICE THE SIZE OF RPZ) •.�IIIII-II �III-11�1i _III 4' 3000 PSI CONCRETE IIII =IITI—IIIII—IIIII_ SLAB, DIMENSI❑NS PER BOX MANUFACTURER fl SPECIFICATI❑NS MINIMUM 2' ANNULAR AREA MINIMUM 2 •=IIIII-IIIII-_~ BRASS FR❑M EELB W 7�► FLET OF ❑W ''' i l 11 1=IIIII=nil 1=11 STANDARD DETAIL UNION COUNTY PUBLIC WORKS DEPARTMENT REDUCED PRESSURE Z 0 N E ASSEMBLY SCALE: UNION COUNTY, N.C. 24A N.T.S. (3/411 _ 211 DATE: I 12-13-13 ASSEMBLY 4' MIN. CLEARANCE F-WITH VALVE OPEN OS & Y GATE VALVE COL ¢ Li w z F- wa ¢i w a Z -- - aL >1< 2'-0' w wn "CLEAR CLEAR DIMENSIONS PER ENCLOSURE MAINTAIN 2' ANNULAR MANUFACTURER SPECIFICATION AREA AROUND DIP AND / COMPACTED> ELECTRICAL CUNDUIT-- JU„UKHLL— APPROVED CLASS 350 DIP RESTRAINED DIP, MJ FITTING "FLOW FLOW APPROVED CLASS 350 DIP, RESTRAINED WEDGE ACTION -11,II Il III, lli =' RETAINER GLAND DETAILSTANDARD REDUCED PRESSURE DETECTOR ASSEMBLY SN.TS. UNION COUNTY PUBLIC WORKS DEPARTMENT 2 4 B UNION COUNTY, N.C. DATE: 1-2-14 EXISTING WATER MAIN THRUST BLOCKING DIP TAPPING SLEEVE & VALVE ENCASEMENT CD CD OPTION "A" TIE IN — DUCTILE IRON DETAIL NOTE: OPTION "A" OR "B" WILL BE REQUIRED, DEPENDING ON THE AMOUNT OF SPACE AVAILABLE, TO BE FIELD VERIFIED EXISTING WATER MAIN THRUST BLO KING RESTRAINT JOINT PIPE FROM VALVE TO 54' PAST CASING TAPPING SLEEVE & VALVE — 54' DIP DIP WATER MAIN w w ENCASEMENT OPTION "B" TIE IN — DI, RESTRAINT JOINT DETAIL UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SCALE: UNION COUNTY, N.C. TAPPING SLEEVE N.T.S. DATE: 11-17-06 NOTES: ESMT/R/W LINE 4" CLEAN OUT EXTENSION 1. THE CLEAN -OUT SHALL BE ADJUSTED TO GRADE TO BE LOWERED AFTER CONNECTION TO BUILDING PLUMBING AND THE POST REMOVED BY THE PLUMBER UPON CONNECTION TO THE TAP. 4"x4"x8' (MIN) POST TO BE 2. PLUMBER SHALL HAVE THE OPTION TO INSTALL A ONE I I I REMOVED AFTER CONNECTION PIECE 4" SCH. 40 COMBINATION WYE TO MINIMIZE 24" CONCRETE I 1 TO BUILDING PLUMBING TRENCH DEPTH OR INSTALL THE SEWER SERVICE MIN PROTECTOR LATERAL FROM THE 4" STUB OUT. RING MIN (SEE NOTE 1) I I FINISHED GRADE 3. ALL CONSTRUCTION BY THE PLUMBER, EITHER OPTION 1 I I OR OPTION 2, SHALL BE INSPECTED AND APPROVED // // BY UNION COUNTY PLUMBING INSPECTOR UNDER A VALID PLUMBING PERMIT. 4. CONTRACTOR OR UNION COUNTY PUBLIC WORKS 4" PVC FEMALE PERSONNEL MAY ADJUST SERVICE LATERAL ELEVATION ADAPTOR W/SHC. 3.0 WITH FITTINGS IF ADEQUATE GRADE EXISTS. 40 PLUG MIN 5. LATERAL CONNECTIONS TO MANHOLES MUST BE CORED AND BOOT INSTALLED. 4" SCH. 40 PVC 4" SCH. 40 - 1/8 BEND OPTIONAL 4" SCH. 40 COMBINATION SOLVENT WELD CONNECTION (TYP) WYE TO BE INSTALLED BY BUILDER'S PLUMBER. '' /��—------� TO BUILDING 4" SCH. 40 PVC NIPPLE. IF BY GRADE EXISTS BY PLUMBER LENGTH VARIES DEPENDING ON TO BUILDING'S FLOOR OPTION 2 DEPTH OF SEWER MAIN TO ELEVATION (SEE NOTE 2) TO BUILDING (SEE NOTE 3) MINIMIZE ADDITIONAL BENDS. BY PLUMBER 4" SCH. 40 COMBINATION WYE OPTION 1 1 DISTANCE VARIES i (SEE NOTE 3) SDR 35 PVC 8x8x4 WYE INSTALL ROTATED 45' FROM THE SPRING LINE SPRING LINE 1% MIN. SLOPE 12" -45' \4" SCH. 40 GRAVITY SEWER MAIN PVC CAP ON (SEE SPECIFICATIONS) 4" STUB OUT wa LT a kzg pq REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD I.D.: NCC18211OSDO PROJECT: ARKA HEIGHTS FOR ARKA HEIGHTS, LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY o 0TL7 ��� ZNGIIN E1ERIPTG NC, PILILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, INC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)30hierEng.com rSHEET TITLE: UTILITY DETAILS SHEET NUMBER: C-505 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211OSDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:57 PM LAST SAVED BY: MMOORE UNION COUNTY PUBLIC WORKS DEPARTMENT STANDARD DETAIL SEWER ATERA SCALE: N.T.S. UNION COUNTY, N.C. DATE: 2/19-14 TEMPORARY SKIMMER BASIN TO BE FILLED ONCE ONSITE STORMWATER SYSTEM IS FULLY STABILIZED N/F BOREN CLAY PRODUCTS, CO. TAX ID.- 09-363-024 DB. 2072, PG 309 TEMPORARY SILT DITCH/BERM CONTRACTOR TO FILL ONCE ON SITE STORMWATER SYSTEM IS STABILIZED MIN. LONGITUDINAL SLOPE OF 1-20/o MIN. V DEPTH MAX. 2:1 SIDE SLOPES RIP RAP & WASHED STONE FILTER BERM (TYP.) \ 660 -^�`\r - �' , 6'-_ 664 \ TOWN OF INDIAN TRAIL 66g' , ----- �\ i �\ S52°16'20"E 956.78' _ O ----------- ---- \\ - / I ♦ - -� ���TFE�--� ---- -- -zLof T- PROP. 4' PERFORATED RISER - 6 WITH \ `, S -�`--------='�-------------- - 5' TRASH RACK - REAR�� Cam_ -PROP. T• CREST ELEV. = 661.50' 25' EMP ROCK . ♦ - CHECK DAM (TYP.) "--TEMPORARY SLOPE DRAIN � a, #LF 13"0 FLEXIBLE PIPE AT • \ ' MIN 0.5% PROP. FAIRCLOTH SKIMMER ' - \> • ■ ' _ INV IN = 664.0' INVERT:659.00' i i �\\ I \ ,�- • _ 1 _� ■ or' \`\ I \`�� INV OUT = 659.0' I1 \ RIP RAP &WASHED STONE � , \ ♦ i O\ I \`\\ FILTER BERM (TYP.) . i '� `♦♦ ' , \ TEMPORARY SLOPE DRAIN 1 424LF 24"0 FLEXIBLE PIPE ) I INV IN = 661.4`'---------- \ \ INV OUT = 659.0' _ _ \ \ N 1 1 \ `TEIVPM*� STOCKPILE TO COMPACT DURING J \\ PLACEMENT. CLEAR ADDITIONAL AREA AS NEEDEDco I \\ I \ TO PLACE/COMPACT DIRT, EXPANDING SILT FENCE \ co Q' TO CONTROL WORK AREA AS REQUIRED. =tr ` \ 724 09 / / '\ SKIMMER BASIN #1 / DRAINAGE AREA: 7.13 AC. DISTURBED AREA: 7.13 AC. LENGTH: +/- 205 FT �` , � `� PROP. , ' WIDTH: +/- 90 FT TEMPORARY / I •I SURFACE AREA PROVIDED: 13733 SF STOCKPILE FOR I ri 559 558 ��0 3L RFACE AREA REQUIRED: 8,888 SF / \ \ TOPSOIL ± CF 661 VOLUME PROVIDED: 47,709 CF 120.000 ♦ MAX. HEIR 662 VOLUME REQUIRED: 12,834 CF '♦ \ / / / 663 TOP OF BERM: 664'`. �\ BOTTOM OF BASIN: 658' \ TOP OF EMERGENCY SPILLWAY: 662.5' \ \ WEIR LENGTH: 40' \ \ SKIMMER PIPE DIA: 1.5" ` SKIMMER ORIFICE DIA: 2.25" A TEMPORARY SLOPED RAIN SKIMMER ORIFICE ELEV: 659' ` #24LF 24"0 FLEXIBLE PIPE DEWATERING TIME: 3.10 DAYS \ INV IN = 664.0' DRAINAGE AREA 1 I f INV OUT = 659.0' AREA = 7.13 ACRES oNUMENr DRAINAGE AREA TO DRAIN TO SKI.M9ER -�� \ ♦ BASIN 1ROUGH -D � ESIO' t-14IANNELS `I \ i ♦ THI V L. ROI ' ��'♦r`\ \�\ \`r\ / \ \ THEN 10 EXISTING STREAM CHANNELS SKIMMER BASIN #1 I I DRAINAGE AREA: 2.30 AC. DISTURBED AREA: 2.30 AC. LENGTH: 210 FT WIDTH:160 FT SURFACE AREA PROVIDED: 33,600 SF SURFACE AREA REQUIRED: 2,867 SF VOLUME PROVIDED: 94,284 CF I -VOLUME REQUIRED: 4,140 CF / TOP OF BERM: 664' BOTTOM OF BASIN: 658' TOP OF EMERGENCY SPILLWAY: 663.5 WEIR LENGTH: 30.0' SKIMMER PIPE DIA: 1.5" SKIMMER ORIFICE DIA: 1.25" SKIMMER ORIFICE ELEV: 659' I DEWATERING TIMEI&Z DAYS j ��'66� -- PROP.4'PERFORATE -WITH 5' TRASH RACK MONUMENT CREST ELEV. = 661.50 664 �S _ _ _ / `♦ • 6° 663 g62 661 ,' I PROP. FPIRCLOTH SKIMI 66 rn INVERT: 659,00' \ � I • I � \ I N/F / I 80REN CLAY / PRODUCTS, CO. _ TAX ID.• 09-366-001 I F�q 658 ) DB. 2072, PG. 309 TEMPORARY SLOPE DRAIN- 7� #LF 13"0 FLEXIBLE PIPE AT � k MIN 0.5% INV IN = 664.0' INV OUT = 659.0' RIP RAP & WASHED STONE FILTER BERM (TYP.) TEMPORARY SILT DITCH/BERM CONTRACTOR TO FILL ONCE ON SITE STORMWATER SYSTEM IS STABILIZED MIN. LONGITUDINAL SLOPE OF 1-2% MIN. V DEPTH MAX. 2:1 SIDE SLOPES DRAINAGE AREA 2 \ AREA = 2.30 ACRES ;� \A\ lot DRAINAGE AREA TO DRAIN TO SKIMMER BASIN 2 THROUGH DIVERSION CHANNELS, ` tq THEN TO EXISTIN TEMPORARY SILT GITCH/BERM G STREAM CHANNELS o ♦ CONTRACTOR TO FILL ONCE I I i I ♦�\ ON SITE STORMWATER SYSTEM IS STABILIZED I \ I '\ I ♦ \ \ MIN. LONGITUDINAL SLOPE Or=♦1-2% I / I♦ I I � I , I� I M� I I I LL l O I � I `Y' II it oL co / I ` / / / " 4 UN D ND ; wv 24" RCP- \`��---------------- EX - MIN. I DEPTH MAX. 2:1 SIDE SLOPES ' / \ S PROP. 10'X18'�\ c\\ �� ` CONCRETE AND TIRE WASH (\ o ' I I `\ kX. CONCRETE / D �.\ f . I\\ �\ / ..4 \. DRIVE TBR a �--s- < > DRAINAGE AREA 3 CmB 0 SETS-� - I -- \\ - 20' S£T�C - -� "-s- r� -'------� co\ ------------------------------- �- ,- -�- ,-- -� b� -��� AREA ACRES i 0.97 bBUFF / `\ o /''b'.: ; 7 `SUS ER /:rb. j� �.. r. / \\ �\ / ----� �-- _ - - - - - - - - ----------------;- 1 - �,------------'�--- - �" { -- � ------------------------J rn f Igor TfL -7 �� =. �; S_5 / I I f,:.';.k 1 % SEX. 197t1 EX. POLE --_------- �S �_ INV.= EX. FH ; J ;' o EX. WM b•... ,'' SEX. POLE ,. ...:\\ �) �� I ,' / EK POLE �3 _�S� / I , F3 >n , , EX. WV' EX. WV -� `6'. b' \ I �\ INV.=662.60 \ \ \ 5 �• OH POLE - - - ..%-:----- - .PRO PR_OPFRTr LINE He _ ' \�•''�, '-9H Op E OH- LOp it _ H� ---- .- ..... _ ------ :T b �� --- -- � --- ----- ------ �- � ----------- - ONED 8 - _ W ' LU IELE----- --- w rub ' - - -� � - ---- ---- OLD CCJHiAR LO �E �H WY' , --- � P1 ------ IP1 '----PED -- - -----57'05 €---------------------- c� OD LOD LOD _.LOpl_= � LOD - 7A 07' (tied T �'� n t(�'----- - - -- ----------- ,.- o--____-, �� �ciauL, / P!I JLeJUI � �"� "166 ------Ald ,, _-------- --------------- ---- ---'' -- - - - -------- --- - _ - - - ------------------- CONS7Rt'66j N ----------------------------------- ---- ENTRANCE- _ --- - ---- --- - --- _ - -- a EDGE OF-1 - - - - - - F_ _ _ EX. EDGE OF _ ' CONCRETE �'T1/� �""INTER �11N---'-----� PAVEMENT EX. POLE - _ `` ' _------_ PAVEMENT - (BY OTHERS,• ,5E£ PLANS MONL;"SENT lNV = I l % N.472, 698.127 p/IE-PAR£ BY KENNEY DESIGN NOTES SEQUENCE OF CONSTRUCTION - PHASE I EROSION AND SEDIMENT • ALL DEMOLITION AND ONSITE HAULING TO BEAN APPROVED LOCATION CONTROL PLAN NARRATIVE: 1. EROSION CONTROL PLAN IS APPROVED BY THE NCDEQ EROSION CONTROL PROGRAM. • TOTAL ON -SITE DISTURBANCE AREA = 9.38 ACRES • CONTRACTOR TO ENSURE ALL DRAINAGE ON -SITE TO DRAIN AWAY FROM ADJACENT PROPERTIES THROUGH 2. PRIOR TO ANY CLEARING, INSTALLATION OF SEDIMENT CONTROL MEASURES, OR GRADING, A PRE -CONSTRUCTION MEETING MUST EXISTING AND PROPOSED DITCHES. BE CONDUCTED ON -SITE WITH THE SEDIMENTATION AND EROSION CONTROL INSPECTOR, UNION COUNTY ENGINEERING DIVISION, • TEMPORARY ON -SITE SKIMMER BASINS TO BE BUILT TO FINAL WET POND BASIN DESIGN DEPTHS. CONTRACTOR TO AND UNION COUNTY PUBLIC SERVICES TO DISCUSS EROSION CONTROL MEASURES. (48 HOURS MINIMUM NOTICE) EXCAVATE SKIMMER BASINS A MINIMUM OF 1' LOWER THAN FINAL BUILD OUT DEPTH TO ALLOW FOR SEDIMENT CLEANOUT. (SEE PERMANENT POND DETAIL SHEET) 3. CONTRACTOR MUST NOTIFY THE NCDEQ SEDIMENTATION AND EROSION CONTROL INSPECTOR 48 HOURS PRIOR TO THE START OF • WHERE SILT FENCE IS NOT PROVIDED, ORANGE MESH SAFETY FENCE IS TO BE PROVIDED TO DELINEATE SITE WORK EARTH DISTURBANCE. AREA. • ANY STONE REQUIRED AT TOE OF SLOPES TO BE FIELD COORDINATED AND PROVIDE AS NEEDED. 4. THE LIMITS OF DISTURBANCE MUST BE FIELD MARKED PRIOR TO INSTALLATION OF SEDIMENT CONTROL MEASURES, DEMOLITION • REFER TO PERMANENT DIVERSIONS (CLEAN WATER DITCH) SPECIFICATIONS IN SECTION 6.21 OF NCDEMLR EROSION OR OTHER LAND DISTURBING ACTIVITIES. AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL (REV. 5/2013) • CONTRACTOR TO REFER TO UNION COUNTY DEVELOPMENT ORDINANCE SECTION 70.030-C "BUFFER VEGETATION 5. INSTALL SEDIMENT AND EROSION CONTROL MEASURES, INCLUDING SILT FENCE, TREE PROTECTION FENCE, (2) SKIMMER BASIN, AND USE" FOR PROPER RIPARIAN BUFFER PROTECTION DURING CONSTRUCTION. DIVERSION DITCHES AND STABILIZED CONSTRUCTION ENTRANCE/EXIT. PRIOR TO BRINGING SKIMMER BASINS ONLINE, • "STREAMSIDE ZONE" OF INTERMITTENT STREAM BUFFER ALLOWED/NOT ALLOWED USES: CONTRACTOR TO INSTALL ASSOCIATED BMP OUTFLOW PIPES TO ENSURE PROPER DRAINAGE TO EXISTING OFFSITE STORMWATER CUTTING OR CLEARING NOT ALLOWED NETWORK. ALSO, AREAS MARKED ON PLANS INDICATING FILLING/CUTTING EXISTING SOIL TO PROMOTE POSITIVE DRAINAGE TO PERPENDICULAR UTILITY CROSSINGS ALLOWED DIVERSION DITCHES SHALL BE COMPLETE PRIOR TO BRINGING BASINS/TRAP ONLINE. NEW PARALLEL SANITARY SEWER LINES ARE ALLOWED AS LONG AS NO "PRACTICABLE ALTERNATIVE" EXISTS AND MITIGATION IS PERFORMED FOR THE IMPACTS PERIMETER CONTROLS SHOULD BE CHECKED DAILY AND ADJUSTED AND/OR REPAIRED TO FULLY CONTAIN AND CONTROL - FENCES PROVIDED INSTALLATION DOES NOT RESULT IN THE REMOVAL OF TREES WITH A 6" DIAMATER AT SEDIMENTATION ON THIS SITE BY CONTRACTOR. PERIMETER CONTROLS ARE TO REMAIN FUNCTIONING FOR THE DURATION OF BREAST HEIGHT OR LARGER THE PROJECT. THE MONITORING AND INSPECTING OF EROSION CONTROL MEASURES SHOULD FOLLOW THE GUIDELINES OF THE - WETLAND/STREAM/BUFFER RESTORATION AND MITIGATION APPROVED BY STATE/FEDERAL AGENCIES NPDES PERMIT (GENERAL PERMIT NCG 010000). NOTE TO GENERAL CONTRACTOR: PRIOR TO CONSTRUCTION, GC MUST CLEARLY DELINEATE AND MARK OFF AREAS IDENTIFIED IN THE SWPPP OR IN THE FIELD, TO BE PROTECTED (SUCH AS NATURAL BUFFERS, TREES, HABITATS OF ENDANGERED/THREATENED SPECIES, HISTORIC PROPERTIES, ETC.). CONTRACTOR IS RESPONSIBLE FOR SITE SECURITY PER CONTRACT. OFF -SITE BORROW AND WASTE: ANY OFF -SITE BORROW OR WASTE REQUIRED FOR THIS PROJECT MUST COME FROM A SITE WITH AN APPROVED EROSION CONTROL PLAN, A SITE REGULATED UNDER THE MINING ACT OF 1971, OR A LANDFILL REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT. TRASH/DEBRIS FROM DEMOLITION ACTIVITIES OR GENERATED BY ANY ACTIVITIES ON SITE MUST BE DISPOSED OF AT A FACILITY REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT, OR PER DIVISION OF SOLID WASTE MANAGEMENT OR DIVISION OF WATER RESOURCES RULES AND REGULATIONS. TEMPORARY SEEDING: THE CONTRACTOR SHALL APPLY TEMPORARY SEEDING AS NEEDED/REQUIRED THROUGHOUT CONSTRUCTION WHENEVER DISTURBED AREA IS TO REMAIN FOR 7 OR MORE DAYS. • "MANAGED USE ZONE" OF INTERMITTENT STREAM BUFFER ALLOWED/NOT ALLOWED USES: ALL USES ALLOWED IN STREAMSIDE ZONE 6. CONTACT SEDIMENTATION AND EROSION CONTROL INSPECTOR UPON COMPLETION OF INSTALLATION OF ALL PERIMETER EROSION OVERHEAD/UNDERGROUND UTILITIES AND SEDIMENT CONTROLS PRIOR TO PROCEEDING WITH ANY OTHER EARTH DISTURBANCE OR GRADING. STORMWATER BMP PER UNION COUNTY STORMWATER DEPARTMENT (6/29/18), GRADING AND FILLING IS ALLOWED IN MANAGED 7. UPON APPROVAL FROM SEDIMENTATION AND EROSION CONTROL INSPECTOR, COMPLETE DEMOLITION OF ANY SITE FEATURES USE ZONE, WHEN ASSOCIATED WITH UNDERGROUND UTILITY CONSTRUCTION (APPROVED USE) AND SHEET (PAVEMENT, CURB, ETC.), CLEARING AND GRUBBING, AND STRIP SITE OF TOP SOIL. FLOW IS MAINTAINED THROUGH THE BUFFER AREA ALL DEMOLISHED MATERIAL IS TO BE DISPOSED IN ACCORDANCE WITH APPLICABLE NORTH CAROLINA REGULATIONS. CONTRACTOR TO ENSURE ALL APPLICABLE DEMOLITION PERMITS HAVE BEEN ISSUED AND HAVE ORIGINALS OF THE SAME PRIOR TO COMMENCING DEMOLITION ACTIVITIES. 8. CONTACT SEDIMENTATION AND EROSION CONTROL INSPECTOR UPON COMPLETION OF STRIPPING, THE STOCKPILING OF TOPSOIL, THE CONSTRUCTION OF TEMPORARY SEDIMENT AND EROSION CONTROL FACILITIES, DISPOSAL OF ALL WASTE MATERIAL, AND PREPARATION OF THE GROUND. LEGEND SITE FEATURES BOUNDARY LINE mimmmiLODimmimmi PROPOSED LIMITS OF DISTURBANCE --,Y,Y,y - EXISTING CONTOUR ELEVATIONS PROPOSED CONTOUR ELEVATIONS EXISTING STORM DRAIN ® PROPOSED STORM DRAIN IXISTING SLOPE ARROW EROSION DETAILS CE CONSTRUCTION EXIT ®F IM%Tt1R&%T FENCE RIP -RAP APRON RPI ROCK PIPE INLET PROTECTION IP1 BLOCK AND GRAVEL INLET PROTECTION IP2 SILT SACK INLET PROTECTION CW CEMENT AND CONCRETE WASHOUT ® $P TEMPORARY STOCKPILE ® $P PERMANENT TOPSOIL STOCKPILE DIVERSION IV RSIONROL CHANNEL WITH EROSION ABRIC CONT$ r]E ORARY SEEDING OR STABILIZATION (SEE NOTE THIS SHEET) ® CD ROCK CHECK DAM B Tg TEMPORARY BAFFLE FAIRCLOTH SKIMMER SB SEDIMENT BASIN -1(- gq 'ORANGE' SAFETY FENCE gq TRAFFIC BARRICADE DRAINAGE AREA 7D 7 DAY STABILIZATION TREE PROTECTION FENCE x- POTENTIAL TREE PROTECTION �F SILT FENCE Xx HIGH HAZARD SILT FENCE SOILS LEGEND CID CHANNERY SILT LOAM (1 TO 5% SLOPES) GOLDSTON-BADIN COMPLEX �S� (2 TO 8% SLOPES) TARRUS GRAVELLY SILT LOAM (2 TO 8% SLOPES) THE SITE WILL BE DEVELOPED IN TWO PHASES. THE PHASING IS BASED ON DEMOLITION OF THE EXISTING SITE FEATURES AND THE CONSTRUCTION OF THE PROPOSED BUILDING AND SITE FEATURES. THE IMPROVEMENTS INCLUDE THE CONSTRUCTION OF EXISTING UTILITIES, LANDSCAPED AREAS, AND ROADWAY WIDENING ALONG OLD CHARLOTTE HIGHWAY. THE DEVELOPMENT IS LOCATED ON A VACANT LOT WITH MAJORITY EXISTING PERVIOUS CONDITIONS INCLUDING FIELDS AND WOODED AREAS. THEREFORE, THE SITE IS NOT EXEMPT FROM STORMWATER MANAGEMENT PRACTICES AND WILL NEED TO OBTAIN APPROPRIATE PERMITS FROM THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY. SILT FENCING IS PROPOSED AROUND THE PERIMETER OF THE PROPERTY TO PROTECT LOCAL RESOURCES AND TO RETAIN SEDIMENT FROM EXITING THE SITE. FENCING IS TO BE REGULARLY INSPECTED FOR DEFICIENCIES AND REQUIRED MAINTENANCE. THE ENTRANCE TO THE CONSTRUCTION SITE WILL INCLUDE THE INSTALLATION OF A STABILIZED CONSTRUCTION ENTRANCES TO REMOVE DEBRIS FROM TRAFFIC ENTERING AND LEAVING THE EXISTING SITE. OFFSITE BORROW SOIL MUST BE APPROVED BY GEOTECHNICAL ENGINEER. (2) TEMPORARY SKIMMER BASIN WILL BE UTILIZED DURING THE TWO PHASES IN ORDER TO PREVENT UNNECESSARY OFFSITE SEDIMENTATION. DIVERSION DITCHES AND CHECK DAMS ARE TO BE USED THROUGHOUT THE SITE TO DIVERT NATURAL FLOW PATTERS TO THE SKIMMER BASIN. 0 40 20 10 0 40 1 "= 40' 01 REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=40' CAD I.D.: NCC182110OP0 PROJECT: ARKA HEIGHTS FOR ARKA HEIGHTS, LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY E2 TM 0 0 J ��� ]ENGHN E]EKING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)30hierEng.com rSHEET TITLE: E&SC PLAN PHASE I SHEET NUMBER: C-601 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION D0CUMENTS\NCC1821100P0.DWG PRINTED BY: MMOORE 12.16.19 @ 5:57 PM LAST SAVED BY: RBRELAND 660 14 - �-- STM _ --- ---� - A-1.1 N/F BOREN CLAY PRODUCTS, CO. TAX 1D.• 09-363-024 DB. 2072, PG 309 \ ♦ '' \\ I TOWN OF lNDIAN TRAIL I , ' \`\ S52°16'20"E 956.78' \ O\ 77M K7F / ---------------------------- �_ _,`" ,,,-''" STM 658 657 656 655 B-EP TM STM ----------- O \ •2.2 B-2.1 / • -- � 6+ STM \ \ 1 Pz z : 4•' B-z \ \ BOREN CLAY APPROX. ADA PRODUCTS, CO. UNIT LOCATION r• . ; TAX 0- 09-366-001 b STM DB. 2072, PG. 309 k `.16 ` I , STM • �� B-1.1 O f , co / r\ � ♦ coo i `♦ i -- BUILDING 4 / +/-15,800 SF / / / 44 UNITS (2 ADA) \ ; APPROX. ADA 64 BEDS O ` FFE: 666.17LL \ \\ LL ------ �' -----' '--------- / � STM 5. '� ' STM ST 6 b, STM STM CLUBHOUSE ' b ' '^' +/ 6 00 SF 1 ... .., . _ -b,. -_ _-________ - - - C E 0 / 1 .. :..' c ` :6. �. ... / . :�:? `'::' :.4 . .. ba : -- -----�-'_'. '-' y`T,` ... STM It „.. ..;:, - FFE.667.5 �• _.::"_ -- _ - - ------ ------------ ---- I APPROX. ADA ... -- b ea ` B 1.5 ... , .. B-1.4 CONCRETE i •'` _ ,- f V � B 1.3 ` I UNIT LOCATION \ STM MONUMENT 1 ro i V ' STM-----------------1.3.1 11 A-2.2 - - - � i � _, '''" �Y' 665 Y�Y • Y • tt IP2 S • \` '> ;N II `II O .. V ` % S ::-• � :. , y..., -- -- t 5------------- � LLi \ 666 IP2 • `` I I BUILDING 1 \` `,` d \ / 666.: it l� \\� II cU- I I " `♦ +/-15,700 SF }'' -- .b. S 5 __ ,�. \ I 4•. b'. :'' -- b.. , ., I / \ 39 UNITS (3 ADA) '. • STM ' 66 BEDS FFE: 667.17 S SA , 6 .8 ' S S S 6 \ / STM ' ,. • UNIT LOCATION \\ UNITLOCATICN \ APPROX.ADA ` aAPPOKADA A ROX. ADA b. \ o / LINI LOCATION STM ` I oN ; y ° i i j. i A-2.6 '', 1\\\ BUILDING 5 ) 'I i11 IP2 BUILDING 6 I i I /:• '...` __ �; ` \+/-10,000 SF I / +/-9,800SF Iu.l i i �''' �" -: ,' : 'b. r'• • e � b: � o F� / WL WL P2 . t b ' u b ' l' / i 45 BEDS I >b' 24 UNITS -('I ADA) \ APPROX. ADA F F I T / i / 42 BEDS d i ty' 'UNIT LOCATION / b `l M M M M ' M I FFE: 668.17 i / f FFE: 667.17 \ F F F I F Pz F (\ \\ I I i i PROP RIW OEM A I \ \ / _ rn . LO o co \ _ is Na _ • .S 'fib 1 s . b 5. - I V. APPROX.ADA • ''�- NIT LOCATION 1 AV FD) - AP"rROX. ADA BUILDING 2 BUILDING BUILDING 3 I '' ` UNIT LOCATION +/-16,300 SF SF 44 UNITS (2 ADA) 45 UNITS (3 ADA) s F 69 BEDS APPROX. ADA 69 BEDS I FFE: 667.17 UNIT LOCATION FFE: 667.17 , J / ♦` co ------ - /' ' ' BATH .' ' •> b, 667 / r - ♦ ♦ I I I I I I I 1 1 / i/ I / / / .b , . . .. .. .. .. .. ... i. / .. .b...b • '%4 ON STM ee TM ::•' o � - -'.\, --- , ND PR PROPFRFYLINE ' STM I STM ♦\♦ ` ' ----- = LO / C_z C-1 nH 4H 9H-9H OH- ----- LOD - - - - - - - - - 1/ _ - S \\`-------W �_iY------ ------ --- ------ ---- _ _ - --- _------------ --- W --- ---------- LOD II L1---------W UCHARLOTTE HWY. W M'24"W 919.83' "" OD LOD LOD LOD 11�01DLOD = _EX 6- _ I I - - -- -_- ---4 ----- T IC�n R L Svv,1 UU r-UDLIL, n/ ✓1) ,'666 PH 1-o k_1 ------------- II ----- -------------------------- ---------- ---------- ---- ---- --- _----------------------- ----------- EX EXEDGE OF EX. EDGE OF �� _ --- -" CONCRETE PAVEMENT \ PAVEMENT \ ` MONO,"SENT I ' / b �' N.•472,698.127 SWPPP UPDATES AND AMENDMENTS SEQUENCE OF CONSTRUCTION - PHASE 11 NOTES • ALL DEMOLITION AND ONSITE HAULING TO BE AN APPROVED LOCATION. THE GC MUST UPDATE THE SWPPP, INCLUDING THE JOBSITE BINDER AND SITE MAPS, TO REFLECT THE PROGRESS OF CONSTRUCTION ACTIVITIES AND 1. CONTACT SEDIMENTATION AND EROSION CONTROL INSPECTOR FOR APPROVAL TO PROCEED. 0 TOTAL ON -SITE DISTURBANCE AREA = 9.38 ACRES GENERAL CHANGES TO THE PROJECT SITE. UPDATES SHALL BE MADE DAILY TO TRACK PROGRESS WHEN ANY OF THE FOLLOWING ACTIVITIES OCCUR: 0 CONTRACTOR TO ENSURE ALL DRAINAGE ON -SITE TO DRAIN AWAY FROM ADJACENT PROPERTIES THROUGH BMP INSTALLATION, MODIFICATION OR REMOVAL, CONSTRUCTION ACTIVITIES (E.G., PAVING, STORM SEWER INSTALLATION, FOOTING INSTALLATION, 2. TEMPORARILY STABILIZE GRADED AREAS (NON -STEEP SLOPES) AS REQUIRED. EXISTING AND PROPOSED DITCHES. ETC.), CLEARING, GRUBBING OR GRADING, OR TEMPORARY OR PERMANENT STABILIZATION. 0 TEMPORARY ON -SITE SKIMMER BASIN TO BE BUILT TO FINAL WET POND BASIN DESIGN DEPTHS. CONTRACTOR TO 3. COMPLETE ROUGH GRADING. COMPLETE THE INSTALLATION OF STORMWATER SYSTEM, TEMPORARY SKIMMER BASIN, SITE UTILITIES, AND EXCAVATE SKIMMER BASINS A MINIMUM OF 1' LOWER THAN FINAL BUILD OUT DEPTH TO ALLOW FOR SEDIMENT IMPORTANT: ALL PERMANENT SOIL SLOPES AS MARKED ON PLANS. CONTRACTOR TO PROVIDE OVERLAND DRAINAGE TOWARD SEDIMENT BASIN UNTIL CLEANOUT. (SEE PERMANENT POND DETAIL SHEET) THE GENERAL CONTRACTOR MUST SUBMIT A REQUEST FOR INFORMATION (RFI) TO THE CIVIL ENGINEERING CONSULTANT (CEC) AND OBTAIN WRITTEN STORM PIPES COMPLETELY INSTALLED, THEN DIVERT TO INLETS. 0 REFER TO PERMANENT DIVERSIONS (CLEAN WATER DITCH) SPECIFICATIONS IN SECTION 6.21 OF NCDEMLR EROSION CEC APPROVAL BEFORE DOING ANY OF THE FOLLOWING: AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL (REV. 5/2013) 4. CONTACT SEDIMENTATION AND EROSION CONTROL INSPECTOR UPON COMPLETION OF ROUGH GRADING, BUT PRIOR TO PLACING TOPSOIL, 0 CONTRACTOR TO REFER TO UNION COUNTY DEVELOPMENT ORDINANCE SECTION 70.030-C "BUFFER VEGETATION 1. MODIFYING EROSION OR SEDIMENT CONTROL BMPS (SUBSTITUTIONS ARE TYPICALLY ONLY APPROVED IF SPECIFIED MATERIALS ARE NOT PERMANENT DRAINAGE, OR OTHER SITE DEVELOPMENT IMPROVEMENTS AND GROUND COVERS. AND USE" FOR PROPER RIPARIAN BUFFER PROTECTION DURING CONSTRUCTION. AVAILABLE OR THERE IS A VALID REASON THE SPECIFIED BMP WILL NOT WORK) • SEE LANDSCAPE PLAN FOR PERMANENT SODDING AND MULCHING. ONCE AREA IS BROUGHT TO GRADE, AREA IS TO 2. ADDING/DELETING EROSION OR SEDIMENT CONTROL BMPS; 5. TEMPORARY SEDIMENT TRAP TO BE FILLED ONCE ONSITE STORMWATER SYSTEM IS STABILIZED. INSTALL CURB ALONG THE PERIMETER OF BE STABILIZED WITHIN 7 DAYS. FOR ANY UNSTABLIZED AREA THAT WILL NOT BE DISTURBED WITHIN 14 DAYS, AREA IS 3. MODIFYING THE SWPPP IMPLEMENTATION SEQUENCE; OR THE SITE TO AID IN THE PROTECTION OF THE EXISTING ADJACENT PROPERTIES AND THE ADJACENT ROADWAYS. TO BE SEEDED WITHIN 7 DAYS OF DISTURBANCE. 4. PERFORMING ANY ACTIONS OR IN ANY MANNER THAT IS CONTRARY TO THE SWPPP. 6. CONTACT SEDIMENTATION AND EROSION CONTROL INSPECTOR PRIOR TO CONVERSION OF BASINS. TEMPORARY BASINS ARE ALLOWED TO 0 PERMANENT GROUNDCOVER WILL BE PROVIDED FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR NO MORE THE CONTRACTOR MAY MODIFY OR ADD ADDITIONAL BMPS, WITHOUT CEC APPROVAL, IN AN EMERGENCY SITUATION TO PREVENT SEDIMENT BE CONVERTED TO PERMANENT BASINS UPON 80% STABILIZATION OF THE CORRESPONDING DRAINAGE AREA. ONCE INSPECTION THAN 90 CALENDAR DAYS (WHICHEVER IS SHORTER). DISCHARGE OR PROTECT WATER QUALITY; HOWEVER, GC MUST NOTIFY THE CEC AS SOON AS PRACTICAL AS TO THEIR ACTIONS TO DISCUSS THE APPROVAL IS RECEIVED, CONVERT SKIMMER BASIN TO STORMWATER PONDS. NEED FOR ADDITIONAL OR SUPPLEMENTAL MEASURES AND TO OBTAIN THE REQUIRED APPROVALS. THE CONTRACTOR IS ULTIMATELY RESPONSIBLE • SEE PERMANENT POND DETAIL SHEET FOR DETAILED POND NOTES. TO ENSURE COMPLIANCE WITH THE PERMIT AND PROTECTION OF DOWNSTREAM WATER QUALITY. 7. KEEP INLET PROTECTION BLOCKED WITH STONE UNTIL STORMWATER SYSTEM IS COMPLETELY INSTALLED. KEEP ROAD WATER DIVERSIONS (WATERBAR, SAND BAG, EROSION EEL, ASPHALT BERM, ETC) UP UNTIL STORMWATER SYSTEM IS 0 WHERE SILT FENCE IS NOT PROVIDED, ORANGE MESH SAFETY FENCE TO BE PROVIDED TO DELINEATE SITE WORK AMENDING THE SWPPP DOES NOT MEAN THAT IT HAS TO BE REPRINTED. IT IS ACCEPTABLE TO ADD ADDENDA SKETCHES NEW SECTIONS DETAILS COMPLETELY INSTALLED AND SEDIMENT BASIN IS CONVERTED TO POST -CONSTRUCTION STORMWATER SCM. AREA. AND/OR REVISED DRAWINGS THAT HAVE THE CEC NAME IN PRINT, ARE STAMPED, SIGNED, DATED, AND ARE ACCOMPANIED BY WRITTEN COPY OF THE ASSOCIATED RFI AND ITS RESPONSE FROM CEC. ENGINEERED ITEMS MUST BE SIGNED AND STAMPED BY THE CEC OF RECORD FOR THE PROJECT. 8. FINE GRADE AND INITIATE FINAL PAVING. PERMANENTLY STABILIZE ANY REMAINING AREAS IN ACCORDANCE WITH THE PERMANENT 0 ANY STONE REQUIRED AT TOE OF SLOPES TO BE FIELD COORDINATED AND PROVIDED AS NEEDED. SODDING SCHEDULE AND NOTES. INSTALL FINAL SITE LANDSCAPING. • TOTAL IMPERVIOUS SURFACE COVERAGE AT BUILT OUT CONDITION (NOT TO INCLUDE STREETS TO BE ACCEPTED BY 9. REQUEST FINAL APPROVAL FROM THE SEDIMENTATION AND EROSION CONTROL INSPECTOR PRIOR TO REMOVING ANY REMAINING NCDOT.). CALCULATIONS ARE AN APPROXIMATION OF TOTAL COVERAGES. SEDIMENT CONTROL MEASURES AND UPON COMPLETION OF FINAL GRADING, PERMANENT DRAINAGE, AND EROSION CONTROL FACILITIES, PERVIOUS COVER = 93,181 SF INCLUDING ESTABLISHED GROUND COVERS AND PLANTING, AND ALL OTHER WORK OF THE BUILDING PERMITS. IMPERVIOUS COVER = 179,587 SF (63% OF TOTAL) • "STREAMSIDE ZONE" OF INTERMITTENT STREAM BUFFER ALLOWED/NOT ALLOWED USES: CUTTING OR CLEARING NOT ALLOWED PERPENDICULAR UTILITY CROSSINGS ALLOWED NEW PARALLEL SANITARY SEWER LINES ARE ALLOWED AS LONG AS NO "PRACTICABLE ALTERNATIVE" EXISTS AND MITIGATION IS PERFORMED FOR THE IMPACTS - FENCES PROVIDED INSTALLATION DOES NOT RESULT IN THE REMOVAL OF TREES WITH A 6" DIAMATER AT BREAST HEIGHT OR LARGER - WETLAND/STREAM/BUFFER RESTORATION AND MITIGATION APPROVED BY STATE/FEDERAL AGENCIES • "MANAGED USE ZONE" OF INTERMITTENT STREAM BUFFER ALLOWED/NOT ALLOWED USES: ALL USES ALLOWED IN STREAMSIDE ZONE OVERHEAD/UNDERGROUND UTILITIES STORMWATER BMP PER UNION COUNTY STORMWATER DEPARTMENT (6/29/18), GRADING AND FILLIING IS ALLOWED IN MANAGED USE ZONE, WHEN ASSOCIATED WITH UNDERGROUND UTILITY CONSTRUCTION (APPROVED USE) AND SHEET FLOW IS MAINTAINED THROUGH THE BUFFER AREA 0 LEGEND SITE FEATURES BOUNDARY LINE �LOD� PROPOSED LIMITS OF DISTURBANCE - -XXX- - EXISTING CONTOUR ELEVATIONS PROPOSED CONTOUR ELEVATIONS EXISTING STORM DRAIN ® PROPOSED STORM DRAIN EXISTING SLOPE ARROW EROSION DETAILS CE CONSTRUCTION EXIT ®F IM%Tt-R&%T FENCE RIP -RAP APRON RPI ROCK PIPE INLET PROTECTION IPl BLOCK AND GRAVEL INLET PROTECTION IP2 O SILT SACK INLET PROTECTION CW CEMENT AND CONCRETE WASHOUT ® $P TEMPORARY STOCKPILE ® $P PERMANENT TOPSOIL STOCKPILE DIVERSION IV RSIONROL CHAN EL WITH EROSION ARIC CONT$ r]E ORARY SEEDING OR STABILIZATION (SEE NOTE THIS SHEET) ® CD ROCK CHECK DAM B TB TEMPORARY BAFFLE FAIRCLOTH SKIMMER SB SEDIMENT BASIN -1(- gq 'ORANGE' SAFETY FENCE gq TRAFFIC BARRICADE DRAINAGE AREA 7D 7 DAY STABILIZATION �W_ TREE PROTECTION FENCE x- POTENTIAL TREE PROTECTION SF SILT FENCE ) X HIGH HAZARD SILT FENCE SOILS LEGEND CID CHANNERY SILT LOAM (1 TO 5% SLOPES) GOLDSTON-BADIN COMPLEX G8B (2 TO 8% SLOPES) TARRUS GRAVELLY SILT LOAM (2 TO 8% SLOPES) 40 20 10 0 40 1 "= 40' 0 o0 LTJa o0 �w m =44 � 4 oQ U44 `az ® m owe CZ '7 44 om � - 13b, p, - - 44 o� e� ow �o r oLL o 01 REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=40' CAD I.D.: NCC1821100P0 PROJECT: ARKA HEIGHTS FOR ARKA HEIGHTS, LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY E2 TM 0 0 J ��� ]ENGHN E]EKING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)3ohlerEng.com SHEET TITLE: E&SCE PLAN P11ASE 11 SHEET NUMBER: cr-1-602 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION D0CUMENTS\NCC1821100P0.DVVG PRINTED BY: MMOORE 12.16.19 @ 5:57 PM LAST SAVED BY: RBRELAND MAINTAIN STOCK PILE SURFACE IN ACCORDANCE WITH TEMPORARY r11\\/UIVV VL/VVIVI IILL JI L.1L VI STOCKPILE TEMPORARY STOCKPILE SOURCE BOX N. T. S. BOHLER LAST REVISED: DETAIL DECEMBER 2014 K :46 OQO om < I ­__I Z 7Dcfj00 r- T, X CD liz--­1=D = O D n m ;Z Do Do = O O O z H U -n o 11 nD> Cn I 1 0 z !7 < m mz r� H Cad to O = Z Cn N D z C D n o N o O � Z > mz Z 0 0 D� Z 0 m 1607.01 ISTING ASPHALT PLAN VIEW EMBANKMENT SHOULD BE MACHINE COMPACTED AND STABILIZATION MATTING PLACED ON SLOPES. SKIMMER 1� ARM BASIN BOTTOM ELEVATION (BE) FLEXIBLE HOSE TEMP. STUB TOP OF EMBANKMENT ELEVATION (ETE) TOP OF EMERGENCY WEIR JEW) Z2 �1 BARREL OUTLET (BOE) BASIN NO. Z1 (FT) Z2 (FT) TOP E. WEIR El TEW (FT) EMBANKMENT CLEAN OUT ELEV COE (FT) BOTTOM ELEV BE (FT) TOP ELEV ETE (FT) 3 3 1 630.45 624.50 618.50 617.50 SKIMMER BASIN NO. DIA Dr (IN) ORIFICE DIA (IN) MAT'L 1 2.5 2.25 PVC NOTES: 1. SEE AND PLACE MATTING FOR EROSION CONTROL ON INTERIOR AND EXTERIOR SIDESLOPES. 2. INSTALL A MINIMUM OF 3 COIR FIVER BAFFLES IN ACCORDANCE WITH PRACTICE STANDARD 6.65. 3. INSTALL SKIMMER AND COUPLING DIRECTLY INTO EMBANKMENT 1 FT. FROM BOTTOM OF BASIN. 4. THE ARM PIPE SHALL HAVE A MINIMUM LENGTH OF 6 FT. BETWEEN THE SKIMMER AND COUPLING. MAINTENANCE NOTES: 1. SKIMMER SEDIMENT BASINS MUST BE INSPECTED AND MUST BE CLEANED WHEN THE ORIGINAL CAPACITY HAS BEEN REDUCED BY 50 PERCENT OR LESS, AS REQUIRED BY THE GOVERNING AGENCY. 2. ALL MATERIAL EXCAVATED FROM BEHIND SEDIMENT BARRIERS OR FROM TRAPS SHALL BE INCORPORATED INTO ON -SITE SOILS OR SPREAD OUT ON AN UPLAND PORTION OF THE SITE AND STABILIZED. 3. VERIFY THAT NO EROSION IS OCCURRING AT DISCHARGE POINTS TO AND FROM IMPOUNDMENTS AND VERIFY THAT TRAP SIDE SLOPES ARE STABILIZED AND SHOW NO SIGNS OF EROSION. SOURCE BOX O TAEL LAST REVISED:CS B SKIMMER BASIN D N.T.S. z 0 O l < < NOTES 0 �z-I0CDDU 0 1. PROVIDE TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGE Q C/) cc z 0 LL 0 H TRUCKS. i _ z w 2. LOCATE ENTRANCES TO PROVIDE FOR UTILIZATION 1LL.0 J BY ALL CONSTRUCTION VEHICLES. 0 c~n Cr 3. MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. r o PERIODIC TOPDRESSING WITH STONE WILL BE NECESSARY. r LU 4. ANY MATERIAL TRACKED ONTO THE ROADWAY MUST BE r CLEANED UP IMMEDIATELY. 5. LOCATE GRAVEL CONSTRUCTION ENTRANCE AT ALL POINTS OF INGRESS AND EGRESS UNTIL SITE IS STABILIZED. PROVIDE FREQUENT CHECKS OF THE DEVICE AND TIMELY MAINTENANCE. 6. NUMBER AND LOCATION OF CONSTRUCTION ENTRANCES TO W BE DETERMINED BY THE ENGINEER. V 7. USE CLASS 'A' STONE OR OTHER COARSE AGGREGATE APPROVED o Z BY THE ENGINEER. 8. INSTALL CONSTRUCTION ENTRANCES IN A WAY TO PREVENT VEHICLES LL FROM BYPASSING CONSTRUCTION ENTRANCE LEAVING PROJECT SITE. z Z W H < Z = O o IH H cc t) < n � z < I -- I- Vi U) Z = O Cn 0 I --I -1 J 0 W w < NOTE: PLACE FILTRATION GEOTEXTILE BENEATH STONE cc 0 1607.01 NOTE TO GC: THE GOAL OF A CONSTRUCTION EXIT AND ASSOCIATED WHEEL WASH AREAS IS TO ELIMINATE TRACK OUT. SIMPLY MANAGING TRACK OUT THROUGH DESIGNATED OR CONTINUAL STREET SWEEPING IS NOT AN ACCEPTABLE PRACTICE. WHILE STREET SWEEPING IS AN ACCEPTABLE PRACTICE FOR REMOVING DUST AND MINIMAL AMOUNTS OF FINE SEDIMENT, OBSERVABLE TRACK OUT FROM THE PROJECT SHOULD TRIGGER THE USE OF ADDITIONAL MEASURES (WHEEL WASH), CONSIDERATION OF ALTERNATE EXITS, OR DISCONTINUING VEHICLE TRAFFIC UNTIL CONDITIONS ON -SITE HAVE IMPROVED. TRACK OUT IS A SEDIMENT RELEASE. ALL SEDIMENT RELEASES MUST BE REPORTED TO THE SWCT VIA THE ONLINE CRITICAL INCIDENT REPORT. WA OUT AREA SOURCE BOX ^off LAST REVISED: STANDARD DETAIL FEBRUARY 2017 SEE SITE MAP FOR LOCATION. SLOPE TO DRAIN N. SOURCE BOX CE CONSTRUCTION EXIT LAST REVISED: STANDARD N.T.S. DETAIL FEBRUARY 2017 Table 0.1 Us Temporary Seeding Recommendations for Late Winter and Early Spring Table 6.1Ob Temporary Seeding Recommendations for Summer Seeding mixture Species Rate (Iblacre) Rye (grain) 120 Annual lespedeza (Kobe in Piedmont and Coastal Plain, Korean in Mountains) 50 Omit annual lespedeza when duration of temporary cover isnot to extend beyond June. Seeding dates Mountains -Above 2500 feet Feb. 15 - May 15 Below 2500 feet: Feh.. II - May 1 Piedmont -Jan. t - May 1 Coastal Plain -Dec. II -Apr. 15 Soil amendments Follow recommendations of soil tests or apply 2,000 Iblacre ground agricultural limestone and 75C lWacre 10-10-10 fertilizer. Mulch Apply 4,00011 straw. Andlor straw by tacking with asphalt, netting, or a mulch anchoring tool. A disk with blades set nearly straight can be used as a mulch anchoring tool. Maintenance Refertilize it growth is not fully adequate. Reseed, refertilize and mulch immedlalely following erosion or other damage. Seeding mixture Species Rate (Iblacre) German millet 40 In the Piedmont and Mau nlairs, a small -stemmed Sudangrass may be suhstioted at a rate of 50 Iblacre- Seeding dates Mountains -May 15-Aug. 15 Piedmont -May 1 -Aug. 15 Coastal Plairr-Apr. 15 -Aug. 15 Sail amendments Follow remmmendat8ons of ..it tests or apply 2,000 Ibd- ground agricu0ural limestone and 750 lWacre 10-10-10 fertilizer. Mulch Apply 4,000lb/acre straw. Anchor straw by tacking with asphalt, netting, or a mulch anchoring tool. A disk with blades set nearly straight can be used as a mulch anchoring tool Maintenance Refertilize if growth is not fully adequate. Reseed, refertilize and mulch immediately following emsion or other damage. Table 6.10c Temporary Seeding Recommendations for Fall Seeding mixture Species Rate (Iblacre) Rye (grain} 120 Seeding dates Noun tains-Aug. 15 - Dec. 15 Coastal Plain and Piedmont -Aug. 15 - Dec. 30 Sold amendments Follow soil tests or apply 2,000 Iblacre ground agricultural limestone and 1,0001bbacre 10-10-10 fertilizer. Mulch Apply 410001biacm straw. Anchor straw by tacking with asphalt, netting, or a mulch anchoring tool. A disk with blades set nearly straight can be used as a mulch anchoring tool. Maintenance Repair and refertilize damaged areas immediately. Topdress with 50 Iblacre of nitrogen. in March. If it is necessary to extent temporary cover beyond June 15, overaeed with 50 Iblacre Kobe (Piedmont and Coastal Plain) or Korean (Mountains) lespedeza in late February or early March. PLANT SELECTION Select an appropriate species or species mixture from Table 6.I0a For seeding in late winter and early spring, Table 6-10b for summer, and Table it For fall. In the Mountains, December and January medings have poor chances of success. When it is necessary to plant at these times, use recommendations for fall art a redly lacked mulch. SEEDING Evenly apply scdd using a cyclone seeder( broadcast), drill, culfipacker seeder, or hydroseeder. Use seeding rates given in Tables 6.10a.-6.10a Broadcast -ruling and hydrosceding are apprapriale for steep slopes where equipment cannot be drixcn. Hand broadcasting is not recommended because of the difficulty in achieving a aDiform distribudu0. Small grains should be planted no more than I inch deep, emit grasses and legumes no more Than F2 inch. Broadcast seed must be covered by raking or chain dragging, and then lightly fumed with a roller or cultipacker. Hyd-sodded mixtures should include a woad filer (cellulose) mulch. SOURCE BOX TEMPORARY SEEDING SPECIFICATION LAST REVISED: NCDEQ TS N.T.S. STANDARD MAY 2013 DETAIL Drape baffle material overwire strand and securewith plastic ties at posts and on wire every 12" 915augeMinHigh -/~ T Tension Wire Strand 3' M1IN Shall Be Secured To Post To Support Baffle Material 31PIPIPipipi !EIMIPIPIP Baffle Material ' If the temporary sediment basin will be converted to a permanent stormwater basin of greater depth, the baffle height should be based on the pool depth during use as a temporary sediment basin. Note: Install three (3) coirfiber baffles in basins at drainage outlets with a spacing of 1 /4 the basin length. Two (2) coir fiber baffles can be installed in the basins less than 20 ft. in length with a spacing of 1/3 the basin length. Extend 9 gauge wireto basin side or install T-post to anchor baffle to side of basin and secure to vertical post 4' Max. --oid , Variable Depth Secure bottom of baffle to ground With 2'staples at 12" maximum spacing. I I i Steel Post 2'-0"Depth Baffle Material should be secured to the bottom Figure 6.65b Coir Fiber Baffle Detail Cross section of a porous baffle in a sediment basin. SOURCE C LAST REVISED: TEMPORARY BAFFLE EQ DETAIL N.T.S. MAY 2013 MAINTENANCE NOTES: 1. SILT SACK SHOULD BE INSPECTED AFTER EVERY MAJOR RAIN EVENT. Silt Sack - Type B 2. IF NO MAJOR RAIN EVENTS, SILT SACK SHOULD BE INSPECTED EVERY Silt Sack - Type A (Without Curb Opening) 2 WEEKS. 3. YELLOW RESTRAINT CORD SHOULD BE VISIBLE AT ALL TIMES. IF CORD IS COVERED WITH SEDIMENT, SILT SACK SHOULD BE EMPTIED. Curb Opening Optional Overflow SIZE 36" X 2411 X to,, GILT CAC C SOURCE BOX LAST REVISED: MANUFACTURER DETAIL FEBRUARY 2014 N.T.S. Curb Deflector Insert 1" Rebar For /--Bag Removal From Inlet (Rebar Not Included) ilt Sack Dump Loops (Rebar Not Included) - W Expansion Restraint GF 0.atwrwFowasd, {e..mom.,ay C[.r+rarred ,I�c i h l �0c C, I1 I c, E`34 F: EIS FE HEI T�LCEI TENSAR - NORTH AMERICAN GREEN SC150 LONGEVITY 24 MO. APPLICATIONS MEDIUM FLOW CHANNELS 2:1-1:1 SLOPES DESIGN UNVEGETATED PERMISSIBLE 2.00(96) SHEAR STRESS Ii (Pa) DESIGN UNVEGETATED PERMISSIBLE 8,00(2.44) VELOCITY ft/s (m/s) TOP NET HEAVYWEIGHT UV -STABILIZED POLYPROPYLENE 2.9 Ibs/1000 ft2 (1.47 1 Trill APPROX WT CENTER NET N/A FIBER MATRIX STRAW/COCONUT MATRIX 70% STRAW 0.35 Il (0.19 1 mi 30% Coconut 0.15 Il (0.08 1 BOTTOM NET LIGHTWEIGHT PHOTODEGRADABLE POLYPROPYLENE 1.50 Ibs/1000 ft2 (0.73 1 Trill APPROX WT THREAD I DEGRADABLE C EROSION CONTROL FABRIC N.T.S. SOURCE BOX BOHLER LAST REVISED: DETAIL DECEMBER 2014 MAINTENANCE NOTES: 1. INSPECT CHECK DAMS AND CHANNELS AT LEAST WEEKLY AND AFTER EACH MAJOR RAINFALL EVENT AND REPAIR IMMEDIATELY. CLEAN OUT SEDIMENT, STRAW, LIMBS, OR OTHER DEBRIS THAT COULD CLOG CHANNEL WHEN NEEDED. 2. ANTICIPATE SUBMERGENCE AND DEPOSITION ABOVE CHECK DAM AND EROSION FROM HIGH FLOWS AROUND EDGES OF THE DAM. CORRECT ALL DAMAGE IMMEDIATELY. 3. REMOVE SEDIMENT ACCUMULATED BEHIND THE DAMS AS NEEDED TO PREVENT DAMAGE TO CHANNEL VEGETATION, ALLOW CHANNEL TO DRAIN THROUGH CHECK DAM, AND NOTES: PREVENT LARGE FLOWS FROM CARRYING SEDIMENT OVER 1. CHECK DAM MAY BE USED IN SLOPING DITCHES OR THE DAM. ADD STONES AS NEEDED TO MAINTAIN DESIGN CHANNELS TO SLOW VELOCITY OR TO CREATE HEIGHT AND CROSS SECTION. SEDIMENT TRAPS. 2. ENSURE THAT MAXIMUM SPACING BETWEEN DAMS PLACES THE TOE OF THE UPSTREAM DAM AT THE SAME ELEVATIONS AS THE DOWNSTREAM DAM. CLASS B EROSION CONTROL STONE L=THE DISTANCE SUCH THAT POINTS A AND B ARE OF EQUAL ELEVATION #57 WASHED STONE �. A B 4TO 6' CROSS SECTION 9" MIN. PROFILE VIEW / 1.5' M IN. FILTER CLOTH PLAN VIEW SOURCE BOX ROCK CHECK DAM BOHLER LAST REVISED: DETAIL CD TEMPORARY AND PERMANENT DECEMBER 2014 N.T.S. PVC VENT PIPE FOR DEWATERI& CONTACT. J.W.FAIRCLOTH & SON TIME TO DEWATE : _ TO _ DA (919) 732-1244 (PHONE/FAX) INLET END. ORIFICE INSIDE PATENT # 5,820,751 SCREEN AND ACCESSIBLE X THROUGH DOOR WATER ENTRY UNIT NOTE: SKIMMER MAY VARY SLIGHTLY FROM ILLUSTRATION PVC ELBOW (TYP.) PVC END CAPS / - A FLOAT - "C" _ ENCLOSURE OUTLET END; ATTACHES TO A SCHEDULE 40 PVC PIPE, WHICH SHALL BE CONNECTED TO TEMPORARY ORIFICE PLATE IN OUTLET STRUCTURE BARREL PIPE LONGER THAN SHOWN NOT INCLUDED WITH SKIMMER, SUPPLIED BY USER. FLEXIBLE HOSE PERSPECTIVE VIEW PVC VENT PIPE (FOR DEWATERING) SCHEDULE 40 PVC PIPE WATER SURFACE ELEVATION n C ORIFICE PLATE FLEXIBLE HOSE E��� PVC TEE SCH 2"x4" PLYWOOD GUIDE ROD (2 TYP.) CLASS B STONE PAD (4' X 4' X 1' MIN.) BOTTOM SURFACE FRONT VIEW IgOS 1.) T MU BE 47 OR IESS MEN N VA10 SURFACE IS a N W Mn1 POOL RM" - N IH MOR a 1IE 2 CFs/ACFE 05131010E 1) ell ItoPE Axe salil ell eE lisaute FmA gun wAD re 10P of sim BEAM. Guet It11PE sou at a See or I-crN t0 am swel WAD FIFE moos nom cIFM our asia M, 70 MP W RE 2 CFS/AC DMIANX 111307011. MAINTENANCE NOTES, 1. INSPECT SKIMMER BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE M ORIGINAL DIMENSIONS WHEN SEDIMENT ACCUMULATES TO HALF THE HEIGHT OF THE FIRST BAFFLE. PULL THE SKIMMER TO THE SIDE SO THAT THE SEDIMENT UNDERNEATH CAN BE EXCAVATED. EXCAVATE SEDIMENT FROM THE ENTIRE BASIN, NOT JUST AROUND SKIMMER OR FIRST CELL MAKE SURE VEGETATION GROWING IN THE BOTTOM OF THE BASIN DOES NOT HOLD DOWN -THE SKIMMER. 2. IF SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, USUALLY JERKING ON THE ROPE WILL MAKE THE SKIMMER BOB UP AND DOWN AND DISLODGE THE DEBRIS AND RESTORE FLOW. IF THIS DOES NOT WORK, PULL THE SKIMMER OVER M THE SIDE OF THE BASIN AND REMOVE THE DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER TO SEE IF IT IS CLOGGED; IF SO, REMOVE DEBRIS. 3. IF THE SKIMMER ARM OR BARREL PIPE IS CLOGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITH A PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. BE SURE AND REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. 4. FREEZING WEATHER CAN RESULT IN ICE FORMING IN THE BASIN. SOME SPECIAL PRECAUTIONS SHOULD BE TAKEN IN THE WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE. )URGE BOX BOHLER LAST REVISED: FAI RCLOTH SKIMMER DETAIL N.T.S. DECEMBER 2014 REVISIONS REV DATE COMMENT BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. ll NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD I.D.: NCC18211OSD0 PROJECT: ARKA HEIGHTS FOR A]E KA HEIGHTS LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY r O o 0 � ��� E `NGH `NIEIEIf$IIFdG 13CP P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@BohlerEng.com SHEET TITLE: EROSION AND SEDIMENT DETAILS SHEET NUMBER 1 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211OSDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:58 PM LAST SAVED BY: MMOORE 12" min. of NCDOT #5 �-- Cross-Section 5, n or #57 washed stone .-- t-\ --�:9,~r,�i{ y �� ------ -�------------------------ 3 3600 cu ft/acre I 5' max 1 .5 •1 'Iter 1• in fi m fabric Design settled 21' Overfill 6" for top min. settlement Plan View � ,•fir `,- *�►_ ., 15 Emergency by 4' 2 y�oQ F pass 6" below ----------- ------ 5----------- min. p max �` settled top of fill 1 - { r+ \ate dam 2' to 3.5' �• ,� , , ti1��+ ---------------- Natural 3 Ground filter fabric min. TEMPORARY SEDIMENT TRAP URCE BOX NCDEQ LAST REVISED: N.T.S. DETAIL JUNE 2006 SILT FENCE FABRIC TO BE FASTENED SECURELY TO WOVEN OR WELDED WIRE FENCE WITH THREE TIES HORIZONTALLY SPACED AT 30" ON CENTER (TYP.) COMPACTED BACKFILL F�°w i Ilii A SECURELY FASTEN OVERLAPPING ENDS OF SILT FENCE FABRIC TO ADJACENT STAKES WITH THREE WIRE TIES OR OTHER FASTENERS WOVEN OR WELDED WIRE FENCE WITH SILT FENCE FABRIC COVER WOODEN SLAT TIED TO STAKE -' TAKE TIE BACKS (TYP.) WITH TWO ADDITIONAL TIES AT INSIDE CORNERS ONLY _ z N COMPACTED FINISHED GRADE BACKFILL UNDISTURBED'/�\\��\\`//`/ GROUND z \� 0 N �IIIII ��il!I �IIIIMIIII��llil � V • FINISHED GRADE 48" MIN. STEEL POSTS (60" MIN. ON SLOPES 3H:1V OR GREATER), DRIVEN MIN. 20" INTO GROUND (MIN. 30" ON SLOPES 3H:1V OR GREATER). WOVEN OR WELDED WIRE FENCE ADJUST POST SPACING SUCH THAT A VERTICAL WIRE IS AT POST USE SINGLE ROLL OF 6.5' WIDE MAT IN TYPICAL DITCH 30" \ - .. f)' - 18" l 0 A \ \ B \ 1 6 C 111 O \ .\ \ CRITICAL POINTS 1 A. OVERLAPS AND SEAMS A B. PROJECTED WATER LINE C. CHANNEL BOTTOM SIDE C SLOPE VERTICES Y O 1. PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. NOTE WHEN USING CELL-G-SEED DO NOT SEED PREPARED AREA CELL-0-SEED MUST BE INSTALLED WITH PAPER SIDE DOWN. 2. BEGIN AT THE TOP OF THE CHANNEL BY ANCHORING THE BLANKET IN A 6" (15om) DEEP X 6" (15cm) WIDE TRENCH WITH APPROXIMATELY 12" (30cm) OF BLANKET EXTENDED BEYOND THE UP -SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED To COMPACTED SOIL AND FOLD REMAINING 12" (30cm) PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30cm) APART ACROSS THE WIDTH OF THE BLANKET. 3. ROLL CENTER BLANKET IN DIRECTION OF WATER FLOW IN BOTTOM OF CHANNEL BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING OPTIONAL DOT SYSTEM, STAPLES/STAKES SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING To THE APPROPRIATE STAPLE PATTERN. 4. PLACE CONSECUTIVE BLANKETS END OVER END (SHINGLE STYLE) WITH A 4"-6" (10cm-15cm) OVERLAP. USE A DOUBLE ROW OF STAPLES STAGGERED 4" (10cm) APART AND 4" (10cm) ON CENTER TO SECURE BLANKETS. 5. FULL LENGTH EDGE OF BLANKETS AT TOP OF SIDE SLOPES MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" 30cm APART IN A 6" 15cm DEEP X 6" 15cm WIDE TRENCH. BACKFILL AND / ( ) ( ) ( ) COMPACT THE TRENCH AFTER STAPLING. 6. ADJACENT BLANKETS MUST BE OVERLAPPED APPROXIMATELY 2"-5" 5cm-12.5cm) AND STAPLED. TO ENSURE PROPER SEAM ALIGNMENT PLACE THE EDGE OF THE OVERLAPPING BLANKET EVEN WITH THE COLORED SEAM STITCH ( ON THE BLANKET BEING OVERLAPPED. 7. IN HIGH FLOW CHANNEL APPLICATIONS, A STAPLE CHECK SLOT IS RECOMMENDED AT 30 TO 40 FOOT (9m-12m) INTERVALS USE A DOUBLE ROW OF STAPLES STAGGERED 4" (10cm) APART AND 4" (10cm) ON CENTER OVER ENTIRE WIDTH OF THE CHANNEL 8. THE TERMINAL END OF THE BLANKETS MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN A 6" (15cm) DEEP X 6" (15cm) WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING MAINTENANCE NOTES: 1. INSPECT AT LEAST WEEKLY AND AFTER EACH MAJOR RAINFALL EVENT. REPAIR IMMEDIATELY. 2. GOOD CONTACT WITH GROUND MUST BE MAINTAINED, AND EROSION MUST NOT OCCUR BENEATH BLANKET. 3. ANY AREAS THAT ARE DAMAGED OR NOT IN CLOSE CONTACT WITH GROUND SHALL BE REPAIRED AND STAPLED. 4. IF EROSION OCCURS DUE TO POORLY CONTROLLED DRAINAGE, THE PROBLEM SHALL BE FIXED AND PROTECTED. 5. MONITOR AND REPAIR AS NECESSARY UNTIL GROUND COVER IS ESTABLISHED. EROSION CONTROL FABRIC SOURCE BOX IN DITCHES BOHLER LAST REVISED: C N.T.S. DETAIL DECEMBER 2014 POSTS: STEEL T OR U TYPE. FENCE: WOVEN OR WELDED WIRE, 14 GA., 6"X6" MAX. MESH OPENING 0 TI-TIE BACKS (TYP.) z 6" X 6" TRENCH COMPACTED BACKFILL 6" X 6" TRENCH EXTEND WOVEN OR WELDED WIRE A MIN. OF 6" INTO TRENCH EXTEND WOVEN OR WELDED WIRE A MIN. OF 6" INTO TRENCH GROUND UNDISTURBED \\\ \� I.: \ '�/.�� L, . I/.� /.� . EMBEDDED SILT FENCE FABRIC MIN. jj\r;x ///xj/i\j/i\j/' 6" INTO GROUND W/ 6" LAID ALONG z ,\\yl /\ BOTTOM OF TRENCH. SOIL SLICING IN j\�I r ACCORDANCE WITH ASTM D 6462 EMBEDDED SILT FENCE FABRIC MIN. 8.2.2 IS ALSO ACCEPTABLE. o j 6" INTO GROUND W/ 6" LAID ALONG BOTTOM OF TRENCH. SOIL SLICING IN ACCORDANCE WITH ASTM D 6462 8.2.2 IS ALSO ACCEPTABLE. A -A -SECTION (FOR SLOPES LESS THAN 3:1) SILT FENCE SILT FENCE TYPE (WIRE SECTION DRAINAGE AVERAGE SECTION BACK OR LENGTH AREA SLOPE OF PHASE SLICED) (FT) (ACRES) AREA 1(TYP.) WIRE BACK 100 0.25 2% 1,2 A -A -SECTION (FOR SLOPES 3:1 AND GREATER) TIE BACK SPECIFICATIONS FOR SILT FENCE INSTALLATION STEEL POST 1. MATERIALS AND INSTALLATION SHALL COMPLY WITH ASTM D 6462 LATEST WIRE FENCE EDITION. 2. INSTALL SILT FENCE AT A FAIRLY LEVEL GRADE ALONG THE CONTOUR WITH THE ENDS CURVED UPHILL TO PROVIDE SUFFICIENT UPSTREAM STORAGE VOLUME FOR THE ANTICIPATED RUNOFF. WOODEN SLAT 3. ATTACH THE GEOTEXTILE OR FABRIC TO THE WOVEN OR WELDED WIRE SILT FENCE FABRIC FENCE WITH THREE WIRE TIES OR OTHER FASTENERS (HORIZONTALLY SPACED EVERY 30"), ALL SPACED WITHIN THE TOP 8" OF THE FABRIC. INSIDE CORNER -PLAN VIEW ATTACH EACH TIE DIAGONALLY 45 DEGREES THROUGH THE FABRIC, WITH EACH PUNCTURE AT LEAST 1" VERTICALLY APART. AT EACH POST, ATTACH THE GEOTEXTILE OR FABRIC AND THE WOVEN OR WELDED WIRE FENCE TO THE POST AS PREVIOUSLY STATED. IN ADDITION, EACH TIE PLACED ON A POST SHOULD BE POSITIONED TO HANG ON A POST NIPPLE WHEN TIGHTENED TO PREVENT SAGGING. 4. WHEN TWO SECTIONS OF SILT FENCE FABRIC ADJOIN EACH OTHER, THEY SHALL BE OVERLAPPED A MINIMUM OF 60" ACROSS TWO POSTS, AS SHOWN. 5. ALL SILT FENCE SHALL INCLUDE WIRE SUPPORT UNLESS THE STATIC SLICING EQUIPMENT IS UTILIZED TO INSTALL THE FENCE PER DETAIL, "SILT FENCE INSTALLATION (SLICING METHOD)". 6. WRAP APPROXIMATELY 6" OF FABRIC AROUND THE END POSTS AND SECURE WITH 3 TIES. 7. COMPACT THE SOIL IMMEDIATELY NEXT TO THE SILT FENCE FABRIC WITH THE FRONT WHEEL OF THE TRACTOR, SKID STEER, OR ROLLER EXERTING AT LEAST 60 POUNDS PER SQ. INCH. COMPACT THE UPSTREAM SIDE FIRST. TABLE 1 Temporary Silt Fence Material Property Requirements COMPACT EACH SIDE TWICE FOR A TOTAL OF FOUR TRIPS. Supported Unsupported Type of Test Method Units Silt Fence Silt Fence Value Grab Strength ASTM D 4632 N (Ibs) Machine Direction 400 550 MARV (90) (90) X-Machine Direction 400 450 MARV (90) (90) Permittivitys ASTM D 4491 sec-1 0.05 0.05 MARV Apparent Opening Sizes ASTM D 4751 mm 0.60 0.60 Max. ARVG (US Sieve #) (30) (30) % 70% after 70% after Typical Ultraviolet Stability ASTM D 4355 Retained 500 h of 500 h of Strength ex osure exposure 8. ADD POST CAPS AS NEEDED BASED ON SITE CONDITIONS AND APPLICABLE AGENCY REQUIREMENTS. MAINTENANCE NOTES 1. SILT FENCES SHALL BE INSPECTED ALONG ITS ENTIRETY AND MUST BE CLEANED WHEN SEDIMENT HAS ACCUMULATED TO ONE-THIRD THE HEIGHT OF THE SILT FENCE. MAINTENANCE CLEANOUT MUST BE CONDUCTED REGULARLY TO PREVENT ACCUMULATED SEDIMENTS FROM REACHING ON -THIRD THE HEIGHT OF THE SILT FENCE. 2. ALL MATERIAL EXCAVATED FROM BEHIND SILT FENCE SHALL BE STOCKPILED ON AN UPLAND PORTION OF THE SITE IF SUITABLE FOR REUSE. 3. SPECIAL ATTENTION SHOULD BE PAID TO ENSURE THAT NO UNDERMINING OF SILT FENCE HAS OCCURRED AND THAT NO BYPASS IS OCCURRING AT JOINING SECTIONS. 4. IF EXCESS SEDIMENT IS ACCUMULATING IN ANY SECTION OF SILT FENCE, THE CONTRACTOR SHOULD IMPLEMENT ADDITIONAL UPSTREAM STABILIZATION MEASURES OR ADDITIONAL BMPS (PENDING CEC APPROVAL) TO PREVENT 12" MIN. FREEBOARD o=�� W� NOTE 2 3 DESIGN FLOW DEPTH 1 - � - \//\\//\\//\\//\\//\\//\\//\\//\\//\\//\\//\ NOTE 1 CHANNEL LINED TO PREVENT EROSION (SEE TABLE IN THIS DETAIL) TYPICAL TRAPEZOIDAL DIVERSION 12" MIN. FREEBOARD �W� NOTE 2 ............................ 3 DESIGN FLOW DEPTHS 1 \-N OTE 1 CHANNEL LINED TO PREVENT EROSION (SEE TABLE IN THIS DETAIL) TYPICAL PARABOLIC DIVERSION 12" MIN. FREEBOARD �W� NOTE 2 3 DESIGN FLOW DEPTH 1 ............................................. /\\\\ //\/�/\\��\\�\\�\\�\\� NOTE 1 CHANNEL LINED TO PREVENT EROSION (SEE TABLE IN THIS DETAIL) NOTES: TYPICAL VEE-SHAPED DIVERSION 1. REMOVE ANY EXISTING VEGETATION AND SCARIFY OR BENCH ADJACENT SOILS PRIOR TO PLACING BERM. 2. BERM MATERIALS MUST BE ADEQUATELY COMPACTED AND IMMEDIATELY STABILIZED. 3. DIVERSION CHANNELS/BERMS MUST BE IMMEDIATELY STABILIZED TO PREVENT EROSION AND TRANSPORT OF SEDIMENT. 4. FOLLOW 02300 EARTHWORK SPECIFICATION. DIVERSION CHANNELS AND BERMS DIVERSION NAME AND SEGMENT LENGTH (FT.) LONGITUDINAL SLOPE DESIGN FLOW DEPTH (IN.) SHAPE (BOTTOM WIDTH, IN.) EROSION PROTECTION TYPE (I.E., MATTING, BLANKET, ETC.) DC1 1110' 1-2% 12" TRIANGLE (-) STRAW WITH NET MATTING DC2 425' 1-2% 12" TRIANGLE (-) STRAW WITH NET MATTING DC3 257' 1-2% 12" TRIANGLE (-) STRAW WITH NET MATTING Silt fence support shall consist of 14 gage steel wire with a mesh spacing of 150 mm (6 in.) or prefabricated polymer mesh of equivalent EXCESSIVE BUILDUP ON SILT FENCE. strength. These default values are based on empirical evidence with a variety of sediments. For environmentally sensitive areas, a review of previous 5. SILT FENCES SHALL BE REPAIRED TO THEIR ORIGINAL CONDITIONS IF experience and/or site or regionally specific geotextile tests in accordance with Test Method D 5141 should be performed by the agency to DAMAGED. confirm suitability of these requirements. As measured in accordance with Test Method D 4632.TABLE 1 TAKEN FROM ASTM D SEDIMENTATION/SILT FENCE SO RC BOX LAST REVISED: SF WITH WIRE BACKING LAST REVISED: STANDARD N.T.S. JUNE 2012 DETAIL JUNE 2012 DC DIVERSION CHANNEL WITH _C ROSION CONTROL FABRIC N.T.S. SECTION - W - PLAN VIEW <0% SLOPE> d � GEOTEXTILE SECTION Y-Y D -� <0% SLOPE> L SECTION Z-Z GEOTEXTILE OUTLET NO. PIPE DIA Pd (IN) RIP RAP APRON SIZE (60) THICK. d (IN) LENGTH L (FT) INITIAL WIDTH Wi (FT) TERMINAL WIDTH W (FT) A2 24 1 0.4 1 9 1 13 1 6 1 15.0 A2.1 18 0.3 9 10 4.5 1 11.5 B1 18 0.4 9 13 1 6 1 15.0 B2 18 0.3 9 10 1 4.5 1 11.5 SOURCE BOX LAST REVISED: BOHLER DETAIL MARCH 2O13 RI PRAP APRON N.T.S. *SEE GRADING PLAN FOR OUTLET INFORMATION* PLAN VIEW OF ROOT ZONE { N0, I DATE I DESCRIPTION I FOR PRUNING SEE NATIONAL ARBORIST ASSOCIATION SPECS. DEAD TREES AND SCRUB OR GROWTH SHALL BE CUT FLUS ADJACENT GRADE. NO GRUB( ALLOWED UNDER DRIP LINE. 2x4" STANDARDS + 1 x4" RAI OR ORANGE SAFETY FENCING MAY BE USED. CONSTRUCTION SPECIFICATIONS 1. LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE ON ITS SIDE IN THE BOTTOM ROW TO ALLOW POOL DRAINAGE. THE FOUNDATION SHOULD BE EXCAVATED AT LEAST 2 INCHES BELOW THE CREST OF THE STORM DRAIN. PLACE THE BOTTOM ROW OF BLOCKS AGAINST THE EDGE OF THE STORM DRAIN FOR LATERAL SUPPORT AND TO AVOID WASHOUTS WHEN OVERFLOW OCCURS. IF NEEDED, GIVE LATERAL SUPPORT TO SUBSEQUENT ROWS BY PLACING 2 X 4 WOOD STUDS THROUGH BLOCK OPENINGS. 2. CAREFULLY FIT HARDWARE CLOTH OR COMPARABLE WIRE MESH WITH 1/2-INCH OPENINGS OVER ALL BLOCK OPENINGS TO HOLD GRAVEL IN PLACE. 3. USE CLEAN GRAVEL, 3/4- TO 1/2-INCH IN DIAMETER, PLACED 2 INCHES BELOW THE TOP OF THE BLOCK ON A 2:1 SLOPE OR FLATTER AND SMOOTH IT TO AN EVEN GRADE. DOT #57 WASHED STONE IS RECOMMENDED. 4. KEEP THE DRAINAGE AREA NO GREATER THAN 1 ACRE. 5. SHALL BE ACCORDANCE WITH THE NCDEQ "EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL" STANDARD # 6.52. MAINTENANCE NOTES: 1. INSPECT BARRIER AT LEAST WEEKLY AND AFTER EVERY MAJOR RAIN EVENT AND MAKE REPAIRS AS NEEDED. 2. REMOVE SEDIMENT AS NECESSARY TO PROVIDE ADEQUATE STORAGE. 3. WHEN CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ALL MATERIALS AND UNSTABLE SOIL. BRING DISTURBED AREA TO PROPER GRADE. STABILIZE ALL BARE AREAS AROUND INLET. SOURCE BOX BOHLER LAST REVISED: DETAIL DECEMBER 2014 45° 4'-0" NOTES: TYPE III BARRICADE - FRONT VIEW 1. THE 9" MIN. x 48% OR 12" MAX. x 48" BARRICADE RAILS SHALL BE FABRICATED FROM 0.125" MAX. PLASTIC SHEETING AND SHALL BE ATTACHED, 4 PER RAIL, WITH 1 INCH NO. 14 PAN HEAD METAL SCREWS OR PLASTIC RIVETS ALL CORNERS SHALL BE ROUNDED. 2. ORANGE AND SILVER (WHITE) STRIPES SHALL BE RETROREFLECTIVE SHEETING, ASTM D 4956 TYPE III, AS SHOWN FOR CONSTRUCTION SIGNS ALTERNATE ORANGE AND SILVER (WHITE) STRIPES 6" WIDE SLOPING DOWNWARD AT AN ANGLE OF 45 DEGREES IN THE DIRECTION TRAFFIC IS TO PASS. 3. IF NECESSARY, THE SANDBAGS SHALL BE FABRICATED AND PLACED ACCORDING TO THE MANUFACTURE'S RECOMMENDATION. 4. THE FRAMING FOR BARRICADE PANELS SHALL BE NCHRP-35D CRASHED TESTED AND FHWA APPROVED. SEE SPECIFICATION SUBSECTION 617.03. TRAFFIC BARRICADES N.T.S. )URCE BOX BOHLER LAST REVISED DETAIL JUNE 2014 NOTES; 1, REMOVE ALL BARRIERS UPON COMPLETION OF PROJECT. 12. BEFORE ANY EXCAVATION TAKES PLACE ON THE SUBJECT SITE, A BARRIER MUST BE ERECTED AROUND THE DRIP LINE OF ALL SUCH TREES SUFFICIENT TO PUT ON NOTICE ALL CONSTRUCTION PERSONELL THAT ANY DISTURBANCE OF THE AREA WITHIN THE DRIPLINE OF SUCH TREES IS PROHIBITED. REQUIRED TREE BARRIERS MUST BE SHOWN TREE PROTECTION DETAIL DEWATERING i4 r, a 4 pT4 u-) r� d 44 le� Be 0 ) P REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF K DATE: 12/11 /2019 BARK SCALE: 1 "=60' AT AREAS CAD I. D.: NCC182110SD0 20TECTED tRIER, APPROVED DATE tfrr CONCRETE BLOCK O I1R�7 • mQ� 0 2:1 SLOPE, GRAVEL FILTER WIRE SCREEN TEMPORARY SEDIMENT POOL V MIN. Z MAX. �� III-I,IV`, Pjll� SEDIMENT e, BLOCK AND AGGREGATE INLET PROTECTION N.T.S. PROJECT: ARKA HEIGHTS FOR A]E KA HEIGHTS LLCM LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY r OTD10 OTI-ITTL�M ]ENIGHMIElE] HMIG 14C, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)3ohlerEng.com SHEET TITLE: EROSION AND SEDIMENT DETAILS SHEET NUMBER 1 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION D0CUMENTS\NCC182110SD0.DVVG PRINTED BY: MMOORE 12.16.19 @ 5:58 PM LAST SAVED BY: MMOORE H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110SDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:58 PM LAST SAVED BY: MMOORE H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110SDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:58 PM LAST SAVED BY: MMOORE 421 16" MAPLE 427 13" CDR 15" OAK 428 I 20" CDR j 429_ 15" DAK 1 16" OAK 430 15" DAK Q � r O c 432 NIF 80REN CLAY 13" OAK PRODUCTS, CO. TAX 10.• 09-363-024 20" CDR ~ z DB. 2072, PG. 309 434 5" OAA SEE SHEET C-702 -; 435- 19" CDR 436� 19" OAK 437 20" OAK 438 20" CDR CONCRETE N53°13'22"W MONUMENT 208 43' (tie) N/F DA AD P. HUDSON GINA L. HUDSON TAX 1D.• 09-366-020A DB. 2072, PG. 309 13" CDR 424 18" OAK PROR TRASH ENCLOSURE (BY OTHERS) 410 14" OAK 408 22 , OAK 407 18" OAK 406 1-18" CDR / VI N/F BOREN CLAY PRODUCTS, CO. TAX 1D.• 09-363-024 DB. 2072, PG. 309 TOWN OF INDIAN TRAIL ,0, OAK PROP. • R SURE I ter` ter`Pi ,ire® 5IGI I e•. APPROX. ADA • UNIT LOCATION N Y � .. APPROX. ADA BUILDING 2 BUILDING 3 UNIT LOCATION +/-16,300 SF +I-16,300 SF F 44 UNITS (2 ADA) 45 UNITS (3 ADA) •,' 69 BEDS APPROX. ADA 69 BEDS FFE: 667.17 UNIT LOCATION FFE: 667.17 ' MI I b PAPPROX. ADA -I UNIT LOCATION 6 439 b 15" MAPLE •° S S 28" OAK 456- 18" PINE LEGEND TREE PROTECTION FENCING LIMITS OF DISTURBANCE •• PRESERVATIONTREE AREA (WITH -• REMOVED)AND EASEMENTS .l /I I ' �I • .. i�l. _�"r►,� UNIT LOCATION UNIT LOCATION + 24 UNITS (1 ADA) 24 UNITS (1 ADA) OCATION�FFE: 668.17 FFE: 667.17 RAMP NCDOT `' �. 11i_ 1►. �►. �►._ 1►i� �►. �►.�►.. _ i�►_.� 1 _� _ 1►.�►i�Sri. _ I _.-,�T ,� ��%� _!r.>�_ �1�� r.. AL <<,., :■ . is = r. •. =ur r +i t BATH b. W F- PROP. ADA CURB' I co RAMP (TYP.) GB CLUBHOUSE > +/-6,000 SF- FFE: 667.5 T F 666 cn r 403 32" OAK 402 20" OAK O 401 18" CDR 40 �1,5'- 6MAPPROXADA _ V:•?r} a UNIT LOCATION �i►%. a , `lip 0, MEN I - �•J �'��� BUILDING 4 44 UNITS (2 ADA) IT LOCATION FFE: 666.17 j !�� IIIIIIIIIIIIIIIIII�4 IGC 4 IG �-- 1 NYSY 1 NYSY II J_ 1GC 41GC 4 � r 0 o � I � - N LO - - - 7- - PR PROPERTY LINE - - LOD �OH�OH -01, W W W W- - W W W w-LOD W n W -W rtbt� rtfll� LOD -W�C�S �-I On - W W W W w W W W - - - - - - 71- - - - - - N53°1124"W 919.83' - - - OD LOD LOD 10'X1o'X'13.T RE�ti PIT LOD 74.07' (tie) OLD CHARLOTTE HWY. I I EX. C/L (SR-1009 60 PUBLIC R/W� I I PH II II EX. EDGE OF EX. EDGE OF FUTURE 8" WATER MAIN CONCRETE PAVEMENT MONUMENT PAVEMENT I I b (BY OTHERS; SEE PLANS N.•472, 698.127 REPARED BY KENNEY DESIGN EX. EDGE OF PLAA 11AG A (U I`aEb. N, , a GROUP, P.A. TITLED "HARKEY E.•1,5123,72.804 N/F PAVEMENT TAX 0- 09-366-154 �� CREEK PHASE 2" TAX 10- 09-366-02OF FUTURE 8" WATER MAIN (BY OTHERS• SEE PLANS 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT EDITION OF THE "ANSI A300 STANDARD FOR TREE, SHRUB, AND OTHER EX. CIL CURRENTLY PREPARED BY KENNEY DESIGN GROUP, P.A. TITLED WOODY PLANT MANAGEMENT -STANDARD PRACTICES" PARTS 2, 5, AND 6 s ACTING AS PROPERLY 1 EX. PROPERTY LINE HARKEY CREEK PHASE 2" 2. ALL LANDSCAPED AREAS ARE TO RECEIVE A MINIMUM OF 4" OF TOPSOIL. \ LINE. SEE SITE PLAN 1 3. ALL MULCHED PLANTING BEDS ADJACENT TO BUILDING SHALL BE SEPARATED FROM FACE OF BUILDING WITH A 3WIDE X 4" DEPTH FOR ROW DEDICATION STRIP LANDSCAPE COMPLIANCE iCHA T I I 4. ALLP ANTEMATERIALOSHALRLE EAHEALTHY, VIGOROUS, AND FREE OF PESTS AND DISEASE. f DETAILS }�� I I I 5. ALL PLANT MATERIAL SHALL BE CONTAINER GROWN OR BALLED AND BURAPPED AS INDICATED IN THE PLANT LIST. UNION COUNTY, NC 1 I 6 UNLESS TREES SHALL HAVEINDICATED.ASTRAIGHT TRUNK, WITH ONE MAIN LEADER AND FULL HEAD AND MEET ALL REQUIREMENTS SPECIFIED \ REQUIREMENT COMPLIANCE STREET 1 SHADE/CANOPY TREE PER 50' O.C. ALONG ALL FRONTAGES. CORNER LOTS SHALL HAVE 1 LOT FRONTAGE ALONG MAIN INTERNAL ROAD: YARD SHADE/CANOPY TREE FOR THE FIRST 100' OF FRONTAGE, THEN 1 TREE PER 50' O.C. 2255 (STREET LENGTH) - 600 (THREE INTERSECTION SETBACKS AT 200 FEET EACH) X 2 SIDES OF SHALL BE LOCATED OUTSIDE OF PUBLIC STREET RIGHT-OF-WAY, AND NO FARTHER THAN 15, FROM ROAD) / 50' = 66 STREET TREES REQUIRED EDGE OF RIGHT-OF-WAY. 115 PROVIDED AT 50' O.C. ON AVERAGE CORNER LOTS: 4 PROVIDED FOR FIRST 100 FEET OF THE LONGEST FRONTAGE BUFFER NO PERIMETER BUFFERS REQUIRED PER 38'H:3'V PLANTED BERM PROVIDED AT NORTH-WEST SIDE OF SITE (TREES PLANTED AT YARD ADJACENT USES 10-12' O.C.). TREE ORNAMENTAL/UNDERSTORY TREES PLANTED MUST HAVE A 2" MINIMUM CALIPER SIZE AND MINIMUM PROVIDED: PRESERVATION HEIGHT OF 4' AT TIME OF PLANTING 65 UNDERSTORY TREES WITH 2" MINIMUM CALIPER AND MINIMUM 8' HEIGHT CONIFER/EVERGREEN TREES PLANTED MUST HAVE A MINIMUM HEIGHT OF 6' AT TIME OF PLANTING CANOPY TREES PLANTED MUST HAVE A 2.5" MINIMUM CALIPER SIZE AND MINIMUM HEIGHT OF 8' AT TIME OF PLANTING NO SHRUB PLANTINGS ARE REQUIRED INTERIOR INTERIOR PARKING LOT LANDSCAPING MUST BE PROVIDED IN THE FORM OF AT LEAST ONE SHAD PROVIDED: PARKING LOT TREE AND 4 SHRUBS PER 10 PARKING SPACES 65 UNDERSTORY TREES WITH 2" LANDSCAPING MINIMUM CALIPER AND MINIMUM 8' HEIGHT REQUIRED INTERIOR PARKING LOT LANDSCAPEING MUST BE PROVIDED IN LANDSCAPE ISLANDS. LANDSCAPE ISLANDS MUST HAVE AN AREA OF AT LEAST 150 SO FT AND BE AT LEAST 8 FEET IN WIDTH. COMBINING LANDSCAPE ISLANDS TO FORM LARGER INTERIOR LANDSCAPE AREAS IS ALLOWED. TREE AND LANDSCAPE MATERIAL LOCATE D OURSIDE THE PERIMETER OF THE PARKING LOT MAY NOT BE COUNTED TOWARD SATISFYING INTERIOR PRKING LOT LANDACAPE REQUIRMENTS. TREES AND LANDSCAPE MATERIAL WITHIN THE CORNERS OF THE PARKING LOT MAY BE COUNTED. 7. ALL MATERIALS ARE SUBJECT TO THE APPROVAL OF THE LANDSCAPE ARCHITECT BEFORE, DURING, AND AFTER INSTALLATION. 1 8. ALL TREES MUST BE GUYED OR STAKED AS SHOWN IN THE DETAILS. GUYS SHALL BE REMOVED AT THE END OF ONE YEAR. 1 9. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL AVOID DAMAGE TO ALL UTILITIES DURING THE COURSE OF THE WORK. LOCATIONS OF EXISTING BURIED UTILITY LINES SHOWN ON THE PLANS ARE BASED UPON BEST AVAILABLE INFORMATION AND ARE TO BE CONSIDERED APPROXIMATE. IT SHALL BE THE \s RESPONSIBILITY OF THE CONTRACTOR 1) TO VERIFY THE LOCATIONS OF UTILITY LINES AND ADJACENT TO THE WORK AREA 2) TO \ PROTECT OF ALL UTILITY LINES DURING THE CONSTRUCTION PERIOD 3) TO REPAIR ANY AND ALL DAMAGE TO UTILITIES, STRUCTURES, SITE APPURTENANCES, ETC. WHICH OCCURS AS A RESULT OF THE CONSTRUCTION. 0 9) 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL QUANTITIES SHOWN ON THESE PANS BEFORE PRICING THE WORK. 60 30 15 0 60 11. CONTRACTOR SHALL BE RESPONSIBLE FOR DELIVERY SCHEDULE AND PROTECTION BETWEEN DELIVERY AND PANTING PER 1 SPECIFICATIONS TO MAINTAIN HEALTHY PLANT CONDITIONS. 1 12. CONTRACTOR TO PROVIDE WATERING SERVICES FOR ALL INSTALLED LANDSCAPE MATERIAL (I.E., TREES, SHRUBS, AWN AREAS, V= 60' AND ANNUALS). WATERING SHALL BE PROVIDED THROUGH ONE FULL GROWING SEASON AND UNTIL LANDSCAPE MATERIAL HAS REACHED SUBSTANTIAL ESTABLISHMENT. THE MEANS AND METHODS FOR PROVIDING WATERING SERVICES SHALL BEAT THE SOLE DISCRETION OF THE LANDSCAPE CONTRACTOR. BEST EFFORTS SHALL BE MADE BY THE CONTRACTOR FOR WATERING SERVICES TO BE PROVIDED DURING OFF PEAK BUSINESS HOURS. WITHIN REASON, VEHICULAR AND PEDESTRIAN AREAS SHALL NOT Or - AFFECTED BY WATERING SERVICES. LANDSCAPE CONTRACTOR TO PROVIDE, IN WRITING, A DESCRIPTION OF THE INTENDED MEANS, METHODS, AND SEASONAL/WEEKLY SCHEDULE OF PROVIDING WATERING SERVICES TO THE SITE FOR CLIENT REVIEW AND APPROVAL. 13. ANY PLANT MATERIAL WHICH IS DISEASED, DISTRESSED, DEAD, OR REJECTED (PRIOR TO SUBSTANTIAL COMPLETION) SHALL BE PROMPTLY REMOVED FROM THE SITE AND REPLACED WITH MATERIAL OF THE SAME SPECIES, QUANTITY, AND SIZE AND MEETING ALL PLANT LIST SPECIFICATIONS. 14. STANDARDS SET FORTH IN "AMERICAN STANDARD FOR NURSERY STOCK" REPRESENT GUIDELINE SPECIFICATIONS ONLY AND SHALL CONSTITUTE MINIMUM QUALITY REQUIREMENTS FOR PANT MATERIAL. 15. WHERE SHOWN ON THE PLANS AND DETAILS, PLANTING BEDS ARE TO BE COMPLETELY COVERED WITH A MINIMUM 4" DEPTH OF TRIPLE SHRED HARDWOOD MULCH FROM A LOCAL MULCH SOURCE HARVESTED IN A SUSTAINABLE MANNER. 16. BIODEGRADABLE WEED MATTING (ALL -PRO WEED MAT OR APPROVED EQUAL) SHALL BE REQUIRED IN SHRUB BEDS AT BUILDING FACADE. 17. ANY TREES, SHRUBS, AND PLANTS SHOWN ON THE LANDSCAPING SHEETS ARE TO BE PLANTED AS PRESCRIBED BY THE LANDSCAPE SHEETS. ANY SUBSTITUTIONS WILL REQUIRE THE APPROVAL OF UNION COUNTY PLANNING DEPARTMENT - URBAN FORESTRY LANDSCAPE SCHEDULE SYM. KEY QTY. BOTANICAL NAME I COMMON NAME CAL. CONT. SIZE Remarks GENERAL TREE PLANTINGS NYSY 34 NYSSA SYLVATICA TUPELO "BLACK GUM" 2.5" CAL B+B 12-14' HT FULL, CENTRAL LEADER IQY QP 25 QUEROUS PALOSRIS OAK 2.5" CAL B+B 12-14' HT FULL, CENTRAL LEADER 7PIN SHRUBS ® IGC 305 ILEX GABRA DWARF INKBERRY HOLLY #5 BEFORE SUBSTITUTION. 18. THE CONTRACTOR IS ENCOURAGED TO COMPLETE TEMPORARY OR PERMANENT SEEDING IN STAGES FOR SOIL STABILIZATION AS AREAS ARE COMPLETED AFTER GRADING. 19. THIS PLAN DOES NOT PRESENT ANY TEMPORARY STABILIZATION REQUIRED AS PART OF SWPPP PAN. 20. ALL STEEP SLOPES LOCATED ON SITE SHALL BE PANTED WITH EITHER SHRUBS, GROUNDCOVERS, OR A NO -MOW MIX OF GRASSES, FOLLOWING FINAL STABILIZATION OF THE SITE. PLANT MATERIALS USED SHALL BE LOW -MAINTENANCE (OR NO MAINTENANCE), AND *SEE SHEET C-702 FOR WET POND(BMP) PLANTINGS AND SCHEDULE PROVIDE COMPLETE COVERAGE OF THE SLOPE TO MINIMIZE EROSION. AL PLANT MATERIAL SHALL BE MAINTAINED IN PERPETUITY. NOTE: ALL DISTURBED AREAS TO RECEIVE 12 LBS PER 1,000 SF OF SEED. UNDISTURBED PROJECT AREAS TO RECEIVE OVERSEED RATE OF 8 LBS PER 1,000 SF. SEED TO BE MIX OF TALL FESCUE (MINIMUM 3 VARIETIES) WELL PERFORMING AND HARDY TO THE REGION. CONTRACTOR TO SUBMIT SEED SPECIFICATION TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 101 REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD I.D.: NCC18211OLPO PROJECT: ARKA HEIGHTS FOR ARKA HEIGHTS, LL� LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY Lj DD OO J ��� ENGINEERING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)30hierEng.com O\ \N CARO: ��� Off•.••'- s •v,• � ''% :U3 2102 ". N DmllSlu\N"`Q\\ SHEET TITLE: LANDSCAPE PLAN SHEET NUMBER: C�T1� H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211OLPO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:58 PM LAST SAVED BY: RBRELAND DAM STRUCTURE/EMBANKMENT INCLUDING FRONT AND BACK SLOPES SHALL BE VEGETATED WITH NON -CLUMPING TURF GRASS. TREES AND WOODY SHRUBS SHALL NOT BE ALLOWED (NCDEQ WET POND MDC 11) O t O All O \. sa° ` z N. ;z- 5 OI N O F- LL ILL LL W� ON +'I. �'I IIIIIIIII, IIIIIIIII, IIIIIIIII, IIIIIIIII, IIIIIIIII, � Z_ `t V 2011 (USl-� Isom 0 CG 464 O DAM STRUCTURE/EMBANKMENT INCLUDING FRONT AND BACK SLOPES SHALL BE VEGETATED WITH NON -CLUMPING TURF GRASS. TREES AND WOODY SHRUBS SHALL NOT BE ALLOWED (NCDEQ WET POND MDC 11) WET POND LANDSCAPE LEGEND. Al:Fm ASCLEPIAS INCARNATA -SWAMP MILKWEED CG: CHELONE GLABRA- WHITE TURTLEHEAD LC- LOBELIA CARDINALIS -CARDINAL FLOWER 0 • ALL HERBACIOUS PLANTS SHALL BE PLANTED ON A DIAGINAL SPREAD PATTERN 0 O 1�4 10 5 2.5 0 10 1"=10' 101 REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1..=60' CAD I.D.: NCC18211OLP0 PROJECT: ARKA HEIGHTS FOR ARKA HEIGHTS, LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY 0 00 J ��� ENGINEERING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)30hierEng.com CARD: ��� Off•.•••• s •v,D � ''% :uj 2102 ". cN Dmilsiu\N"`Q\\ SHEET TITLE: WET POND PLANTING PLAN SHEET NUMBER C�L1� H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110LPO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:58 PM LAST SAVED BY: RBRELAND j i I I I 1 � I I I I 1 I I I II I TREE MITIGATION CALCULATIONS. 1. THE BELOW TREE PRESERVATION CALCULATIONS ARE BASED UPON THE UNION COUNTY DEVELOPMENT ORDINANCE SECTION 55.030 REQUIREMENTS: 1.1. TOTAL SETBACK AREA WITHIN SITE (BASED ON PREVIOUS ZONING DESIGNATION OF RA-40) - EXISTING & PROPOSED STREET R.O.W. -ALL ON -SITE UTILITY EASEMENTS (SEE PLAN FOR AREA) 1.2. TOTAL DBH OF (12" OR GREATER) EXISTING TREES REMOVED FROM SETBACK AREA THAT REQUIRE MITIGATION = 154" 1.3. 154" (TOTAL DBH) X 1.25 = 193" (TOTAL DBH TO BE MITIGATED) [SEE PLANS FOR PROPOSED TREE PLANTINGS] N/F BOREN CLAY PRODUCTS, CO. TAV In. nn 7C7 n7A L,II IL tT UII IL tt UII IL IT L,II IL tT 377 18" OAK 398 14" OAK 419 15" OAK 441 42" OAK 378 14" OAK 399 13" GUM 420 21" OAK 442 18" OAK 379 22" OAK 400 18" PINE 421 16" MAPLE 443 20" OAK 380 21" OAK 401 18" CDR 422 19" OAK 444 42" OAK 381 25" OAK 402 20" OAK 423 21" MAPLE 445 12" OAK 382 16" OAK 403 32" OAK 424 18" OAK 446 16" OAK 383 13" OAK 404 32" OAK 425 13" CDR 447 17" OAK 384 19" OAK 405 18" OAK 426 13" CDR 448 22" OAK 385 22" OAK 406 18" CDR 427 15" OAK 449 18" OAK 386 22" OAK 407 18" OAK 428 20" CDR 450 40" OAK 387 14" OAK 408 22" OAK 429 15" OAK 451 42" OAK 388 16" OAK 409 25" OAK 430 15" OAK 452 42" OAK 389 18" OAK 410 14" OAK 431 16" OAK 453 16" OAK 390 25" OAK 411 18" OAK 432 13" OAK 454 15" OAK 391 18" CDR 412 18" OAK 433 20" CDR 455 28" OAK 392 16" OAK 413 20" MAPLE 434 15" OAK 456 18" PINE 393 12" OAK 414 18" OAK 435 19" CDR 598 20" MAPLE 394 15" CDR 415 12" MAPLE 436 19" OAK 599 38" OAK 395 13" OAK 416 17" OAK 437 20" OAK 600 60" OAK 396 18" PINE 417 j 22" OAK j 438 j 20" CDR j 601 j 52" OAK 397 20" CDR 1 418 1 15" OAK 1 439 1 15" MAPLE 1 602 1 28" OAK TREES REMOVED FROM PRESERVATION AREA MITIGATION TREE PLANTINGS CLAY S, CO. -366-001 PG. J09 CmB CHARLOTTE E HWY. 9D LaEGaEND TREE PROTECTION TREE ID NO. SPECIES SIZE(DBH) NO. OF TREES SPECIES SIZE (DBH TOTAL) FENCING 409 OAK 25" 58 - PROPOSED PLANTINGS, LIMITS OF SEE LANDSCAPE PLAN PINE 116" DISTURBANCE 418 OAK 15" 6 - PRESERVED EXISTING TREE TREES OUTSIDE OAK/MAPLE 112" PRESERVATION 419 OAK 15" 420 OAK 21" PRESERVATION BUFFER AREA (WITH ROW AND EASEMENTS 4" 22 OAK 19"REMOVED)REMOVED) 423 MAPLE 21" 424 OAK 18" 598 MAPLE 20" LOD LOD REVISIONS REV DATE COMMENT BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD I.D.: NCC182110LP0 PROJECT: ARKA HEIGHTS FOR ARKA HEIGHTS, LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY o O� ��� ]ENGINEERING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)30hierEng.com \\\\\\��\\un; I I I 111111 ///111// O\\ �N CARO: Off•.•••• s •.� ''% P A •� :Wuj 2102 ". N Dmilsiu\N"`Q\\ SHEET TITLE: MITIGATION PLAN SHEET NUMBER: C-703 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211OLPO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:58 PM LAST SAVED BY: RBRELAND LANDSCAPE SPECIFICATIONS ATIONS 1. SCOPE OF WORK: THE LANDSCAPE CONTRACTOR SHALL BE REQUIRED TO PERFORM ALL CLEARING, FINISHED GRADING, SOIL PREPARATION PERMANENT SEEDING OR SODDING PLANTING AND MULCHING INCLUDING ALL LABOR MATERIALS TOOLS AND EQUIPMENT NECESSARY FOR THE COMPLETION OF THIS PROJECT, UNLESS OTHERWISE CONTRACTED BY THE GENERAL CONTRACTOR. 2. MATERIALS A. GENERAL - ALL HARDSCAPE MATERIALS SHALL MEET OR EXCEED SPECIFICATIONS AS OUTLINED IN THE STATE DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS. B. TOPSOIL - NATURAL, FRIABLE, LOAMY SILT SOIL HAVING AN ORGANIC CONTENT NOT LESS THAN 5%, A PH RANGE BETWEEN 4.5-7.0. IT SHALL BE FREE OF DEBRIS, ROCKS LARGER THAN ONE INCH (1"), WOOD, ROOTS, VEGETABLE MATTER AND CLAY CLODS. C. LAWN - ALL DISTURBED AREAS ARE TO BE TREATED WITH A MINIMUM SIX INCH (6") THICK LAYER OF TOPSOIL, OR AS DIRECTED BY THE LOCAL ORDINANCE OR CLIENT, AND SEEDED OR SODDED IN ACCORDANCE WITH THE PERMANENT STABILIZATION METHODS INDICATED WITHIN THE SOIL EROSION AND SEDIMENT CONTROL NOTES. 1.1. LAWN SEED MIXTURE SHALL BE FRESH, CLEAN NEW CROP SEED. 1.2. SOD SHALL BE STRONGLY ROOTED, WEED AND DISEASE/PEST FREE WITH A UNIFORM THICKNESS. 1.3. SOD INSTALLED ON SLOPES GREATER THAN 4:1 SHALL BE PEGGED TO HOLD SOD IN PLACE. D. MULCH - THE MULCH AROUND THE PERIMETER OF THE BUILDING SHALL BE A 3" LAYER OF DOUBLE SHREDDED BLACK CEDAR MULCH ONLY. ALL OTHER AREAS SHALL BE MULCHED WITH A 3" LAYER OF DOUBLE SHREDDED DARK BROWN HARDWOOD BARK MULCH, UNLESS OTHERWISE STATED ON THE LANDSCAPE PLAN. E. FERTILIZER 1.1. FERTILIZER SHALL BE DELIVERED TO THE SITE MIXED AS SPECIFIED IN THE ORIGINAL UNOPENED STANDARD BAGS SHOWING WEIGHT, ANALYSIS AND NAME OF MANUFACTURER. FERTILIZER SHALL BE STORED IN A WEATHERPROOF PLACE SO THAT IT CAN BE KEPT DRY PRIOR TO USE. 1.2. FOR THE PURPOSE OF BIDDING, ASSUME THAT FERTILIZER SHALL BE 10% NITROGEN, 6% PHOSPHORUS AND 4% POTASSIUM BY WEIGHT. A FERTILIZER SHOULD NOT BE SELECTED WITHOUT A SOIL TEST PERFORMED BY A CERTIFIED SOIL LABORATORY. F. PLANT MATERIAL 1.1. ALL PLANTS SHALL IN ALL CASES CONFORM TO THE REQUIREMENTS OF THE "AMERICAN STANDARD FOR NURSERY STOCK" (ANSI Z60.1), LATEST EDITION, AS PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION. 1.2. IN ALL CASES, BOTANICAL NAMES SHALL TAKE PRECEDENCE OVER COMMON NAMES FOR ANY AND ALL PLANT MATERIAL. 1.3. PLANTS SHALL BE LEGIBLY TAGGED WITH THE PROPER NAME AND SIZE. TAGS ARE TO REMAIN ON AT LEAST ONE PLANT OF EACH SPECIES FOR VERIFICATION PURPOSES DURING THE FINAL INSPECTION. 1.4. TREES WITH ABRASION OF THE BARK, SUN SCALDS, DISFIGURATION OR FRESH CUTS OF LIMBS OVER 1 Y4', WHICH HAVE NOT BEEN COMPLETELY CALLUSED, SHALL BE REJECTED.PLANTS SHALL NOT BE BOUND WITH WIRE OR ROPE AT ANY TIME SO AS TO DAMAGE THE BARK OR BREAK BRANCHES. 1.5. ALL PLANTS SHALL BE TYPICAL OF THEIR SPECIES OR VARIETY AND SHALL HAVE A NORMAL HABIT OF GROWTH: WELL DEVELOPED BRANCHES, DENSELY FOLIATED, VIGOROUS ROOT SYSTEMS AND BE FREE OF DISEASE, INSECTS, PESTS, EGGS OR LARVAE. 1.6. CALIPER MEASUREMENTS OF NURSERY GROWN TREES SHALL BE TAKEN AT A POINT ON THE TRUNK SIX INCHES (6") ABOVE THE NATURAL GRADE FOR TREES UP TO AND INCLUDING A FOUR INCH (4") CALIPER SIZE. IF THE CALIPER AT SIX INCHES (6") ABOVE THE GROUND EXCEEDS FOUR INCHES (4") IN CALIPER, THE CALIPER SHOULD BE MEASURED AT A POINT 12" ABOVE THE NATURAL GRADE. 1.7. SHRUBS SHALL BE MEASURED TO THE AVERAGE HEIGHT OR SPREAD OF THE SHRUB, AND NOT TO THE LONGEST BRANCH. 1.8. TREES AND SHRUBS SHALL BE HANDLED WITH CARE BY THE ROOT BALL. 3. GENERAL WORK PROCEDURES A. CONTRACTOR TO UTILIZE WORKMANLIKE INDUSTRY STANDARDS IN PERFORMING ALL LANDSCAPE CONSTRUCTION. THE SITE IS TO BE LEFT IN A CLEAN STATE AT THE END OF EACH WORKDAY. ALL DEBRIS, MATERIALS AND TOOLS SHALL BE PROPERLY STORED, STOCKPILED OR DISPOSED OF. B. WASTE MATERIALS AND DEBRIS SHALL BE COMPLETELY DISPOSED OF AT THE CONTRACTOR'S EXPENSE. DEBRIS SHALL NOT BE BURIED, INCLUDING ORGANIC MATERIALS, BUT SHALL BE REMOVED COMPLETELY FROM THE SITE. 4. SITE PREPARATIONS A. BEFORE AND DURING PRELIMINARY GRADING AND FINISHED GRADING, ALL WEEDS AND GRASSES SHALL BE DUG OUT BY THE ROOTS AND DISPOSED OF IN ACCORDANCE WITH GENERAL WORK PROCEDURES OUTLINED HEREIN. B. ALL EXISTING TREES TO REMAIN SHALL BE PRUNED TO REMOVE ANY DAMAGED BRANCHES. THE ENTIRE LIMB OF ANY DAMAGED BRANCH SHALL BE CUT OFF AT THE TRUNK. CONTRACTOR SHALL ENSURE THAT CUTS ARE SMOOTH AND STRAIGHT. ANY EXPOSED ROOTS SHALL BE CUT BACK WITH CLEAN, SHARP TOOLS AND TOPSOIL SHALL BE PLACED AROUND THE REMAINDER OF THE ROOTS. EXISTING TREES SHALL BE MONITORED ON A REGULAR BASIS FOR ADDITIONAL ROOT OR BRANCH DAMAGE AS A RESULT OF CONSTRUCTION. ROOTS SHALL NOT BE LEFT EXPOSED FOR MORE THAN ONE (1) DAY. CONTRACTOR SHALL WATER EXISTING TREES AS NEEDED TO PREVENT SHOCK OR DECLINE. C. CONTRACTOR SHALL ARRANGE TO HAVE A UTILITY STAKE -OUT TO LOCATE ALL UNDERGROUND UTILITIES PRIOR TO INSTALLATION OF ANY LANDSCAPE MATERIAL. UTILITY COMPANIES SHALL BE CONTACTED THREE (3) DAYS PRIOR TO THE BEGINNING OF WORK. 5. TREE PROTECTION A. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING TREES TO REMAIN. A TREE PROTECTION ZONE SHALL BE ESTABLISHED AT THE DRIP LINE OR 15 FEET FROM THE TRUNK OR AT THE LIMIT OF CONSTRUCTION DISTURBANCE, WHICHEVER IS GREATER. LOCAL STANDARDS THAT MAY REQUIRE A MORE STRICT TREE PROTECTION ZONE SHALL BE HONORED. B. A FORTY-EIGHT INCH (48") HIGH WOODEN SNOW FENCE OR ORANGE COLORED HIGH -DENSITY 'VISI-FENCE', OR APPROVED EQUAL, MOUNTED ON STEEL POSTS SHALL BE PLACED ALONG THE BOUNDARY OF THE TREE PROTECTION ZONE. POSTS SHALL BE LOCATED AT A MAXIMUM OF EIGHT FEET (8') ON CENTER OR AS INDICATED WITHIN THE TREE PROTECTION DETAIL. C. WHEN THE TREE PROTECTION FENCING HAS BEEN INSTALLED, IT SHALL BE INSPECTED BY THE APPROVING AGENCY PRIOR TO DEMOLITION, GRADING, TREE CLEARING OR ANY OTHER CONSTRUCTION. THE FENCING ALONG THE TREE PROTECTION ZONE SHALL BE REGULARLY INSPECTED BY THE LANDSCAPE CONTRACTOR AND MAINTAINED UNTIL ALL CONSTRUCTION ACTIVITY HAS BEEN COMPLETED. D. AT NO TIME SHALL MACHINERY, DEBRIS, FALLEN TREES OR OTHER MATERIALS BE PLACED, STOCKPILED OR LEFT STANDING IN THE TREE PROTECTION ZONE. 6. SOIL MODIFICATIONS A. CONTRACTOR SHALL ATTAIN A SOIL TEST FOR ALL AREAS OF THE SITE PRIOR TO CONDUCTING ANY PLANTING. SOIL TESTS SHALL BE PERFORMED BY A CERTIFIED SOIL LABORATORY. B. LANDSCAPE CONTRACTOR SHALL REPORT ANY SOIL OR DRAINAGE CONDITIONS CONSIDERED DETRIMENTAL TO THE GROWTH OF PLANT MATERIAL. SOIL MODIFICATIONS, AS SPECIFIED HEREIN, MAY NEED TO BE CONDUCTED BY THE LANDSCAPE CONTRACTOR DEPENDING ON SITE CONDITIONS. C. THE FOLLOWING AMENDMENTS AND QUANTITIES ARE APPROXIMATE AND ARE FOR BIDDING PURPOSES ONLY. COMPOSITION OF AMENDMENTS SHOULD BE REVISED DEPENDING ON THE OUTCOME OF A TOPSOIL ANALYSIS PERFORMED BY A CERTIFIED SOIL LABORATORY. 1.1. TO INCREASE A SANDY SOIL'S ABILITY TO RETAIN WATER AND NUTRIENTS, THOROUGHLY TILL ORGANIC MATTER INTO THE TOP 6-12". USE COMPOSTED BARK, COMPOSTED LEAF MULCH OR PEAT MOSS. ALL PRODUCTS SHOULD BE COMPOSTED TO A DARK COLOR AND BE FREE OF PIECES WITH IDENTIFIABLE LEAF OR WOOD STRUCTURE. AVOID MATERIAL WITH A PH HIGHER THAN 7.5. 1.2. TO INCREASE DRAINAGE, MODIFY HEAVY CLAY OR SILT (MORE THAN 40% CLAY OR SILT) BY ADDING COMPOSTED PINE BARK (UP TO 30% BY VOLUME) AND/OR AGRICULTURAL GYPSUM. COARSE SAND MAY BE USED IF ENOUGH IS ADDED TO BRING THE SAND CONTENT TO MORE THAN 60% OF THE TOTAL MIX. SUBSURFACE DRAINAGE LINES MAY NEED TO BE ADDED TO INCREASE DRAINAGE. 1.3. MODIFY EXTREMELY SANDY SOILS (MORE THAN 85%) BY ADDING ORGANIC MATTER AND/OR DRY, SHREDDED CLAY LOAM UP TO 30% OF THE TOTAL MIX. 7. FINISHED GRADING A. UNLESS OTHERWISE CONTRACTED, THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF TOPSOIL AND THE ESTABLISHMENT OF FINE -GRADING WITHIN THE DISTURBANCE AREA OF THE SITE. B. LANDSCAPE CONTRACTOR SHALL VERIFY THAT SUBGRADE FOR INSTALLATION OF TOPSOIL HAS BEEN ESTABLISHED. THE SUBGRADE OF THE SITE MUST MEET THE FINISHED GRADE LESS THE REQUIRED TOPSOIL THICKNESS (1"t). C. ALL LAWN AND PLANTING AREAS SHALL BE GRADED TO A SMOOTH, EVEN AND UNIFORM PLANE WITH NO ABRUPT CHANGE OF SURFACE AS DEPICTED WITHIN THIS SET OF CONSTRUCTION PLANS, UNLESS OTHERWISE DIRECTED BY THE PROJECT ENGINEER OR LANDSCAPE ARCHITECT. D. ALL PLANTING AREAS SHALL BE GRADED AND MAINTAINED TO ALLOW FREE FLOW OF SURFACE WATER IN AND AROUND THE PLANTING BEDS. STANDING WATER SHALL NOT BE PERMITTED IN PLANTING BEDS. 8. TOPSOILING A. CONTRACTOR SHALL PROVIDE A SIX INCH (6") THICK MINIMUM LAYER OF TOPSOIL, OR AS DIRECTED BY THE LOCAL ORDINANCE OR CLIENT, IN ALL PLANTING AREAS. TOPSOIL SHOULD BE SPREAD OVER A PREPARED SURFACE IN A UNIFORM LAYER TO ACHIEVE THE DESIRED COMPACTED THICKNESS. B. ON -SITE TOPSOIL MAY BE USED TO SUPPLEMENT THE TOTAL AMOUNT REQUIRED. TOPSOIL FROM THE SITE MAY BE REJECTED IF IT HAS NOT BEEN PROPERLY REMOVED, STORED AND PROTECTED PRIOR TO CONSTRUCTION. C. CONTRACTOR SHALL FURNISH TO THE APPROVING AGENCY AN ANALYSIS OF BOTH IMPORTED AND ON -SITE TOPSOIL TO BE UTILIZED IN ALL PLANTING AREAS. THE PH AND NUTRIENT LEVELS MAY NEED TO BE ADJUSTED THROUGH SOIL MODIFICATIONS AS NEEDED TO ACHIEVE THE REQUIRED LEVELS AS SPECIFIED IN THE MATERIALS SECTION ABOVE. D. ALL PLANTING AND LAWN AREAS ARE TO BE CULTIVATED TO A DEPTH OF SIX INCHES (6"). ALL DEBRIS EXPOSED FROM EXCAVATION AND CULTIVATION SHALL BE DISPOSED OF IN ACCORDANCE WITH GENERAL WORK PROCEDURES SECTION ABOVE. THE FOLLOWING SHALL BE TILLED INTO THE TOP FOUR INCHES (4") IN TWO DIRECTIONS (QUANTITIES BASED ON A 1,000 SQUARE FOOT AREA): 1.1. 20 POUNDS 'GROW POWER' OR APPROVED EQUAL 1.2. 20 POUNDS NITRO -FORM (COURSE) 38-0-0 BLUE CHIP E. THE SPREADING OF TOPSOIL SHALL NOT BE CONDUCTED UNDER MUDDY OR FROZEN CONDITIONS. 9. PLANTING A. INSOFAR THAT IT IS FEASIBLE, PLANT MATERIAL SHALL BE PLANTED ON THE DAY OF DELIVERY. IN THE EVENT THAT THIS IS NOT POSSIBLE, LANDSCAPE CONTRACTOR SHALL PROTECT UNINSTALLED PLANT MATERIAL. PLANTS SHALL NOT REMAIN UNPLANTED FOR LONGER THAN A THREE DAY PERIOD AFTER DELIVERY. PLANTS THAT WILL NOT BE PLANTED FOR A PERIOD OF TIME GREATER THAN THREE DAYS SHALL BE HEALED IN WITH TOPSOIL OR MULCH TO HELP PRESERVE ROOT MOISTURE. B. PLANTING OPERATIONS SHALL BE PERFORMED DURING PERIODS WITHIN THE PLANTING SEASON WHEN WEATHER AND SOIL CONDITIONS ARE SUITABLE AND IN ACCORDANCE WITH ACCEPTED LOCAL PRACTICE. PLANTS SHALL NOT BE INSTALLED IN TOPSOIL THAT IS IN A MUDDY OR FROZEN CONDITION. C. ANY INJURED ROOTS OR BRANCHES SHALL BE PRUNED TO MAKE CLEAN-CUT ENDS PRIOR TO PLANTING UTILIZING CLEAN, SHARP TOOLS. ONLY INJURED OR DISEASED BRANCHING SHALL BE REMOVED. D. ALL PLANTING CONTAINERS AND NON -BIODEGRADABLE MATERIALS SHALL BE REMOVED FROM ROOT BALLS DURING PLANTING. NATURAL FIBER BURLAP MUST BE CUT FROM AROUND THE TRUNK OF THE TREE AND FOLDED DOWN AGAINST THE ROOT BALL PRIOR TO BACKFILLING. E. POSITION TREES AND SHRUBS AT THEIR INTENDED LOCATIONS AS PER THE PLANS AND SECURE THE APPROVAL OF THE LANDSCAPE ARCHITECT PRIOR TO EXCAVATING PITS, MAKING NECESSARY ADJUSTMENTS AS DIRECTED. F. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, THE PROPOSED LANDSCAPE, AS SHOWN ON THE APPROVED LANDSCAPE PLAN, MUST BE INSTALLED, INSPECTED AND APPROVED BY THE APPROVING AGENCY. THE APPROVING AGENCY SHALL TAKE INTO ACCOUNT SEASONAL CONSIDERATIONS IN THIS REGARD AS FOLLOWS. THE PLANTING OF TREES, SHRUBS, VINES OR GROUND COVER SHALL OCCUR ONLY DURING THE FOLLOWING PLANTING SEASONS: 1.1. PLANTS: MARCH 15 TO DECEMBER 15 1.2. LAWN: MARCH 15 TO JUNE 15 OR SEPT. 1 TO DECEMBER 1 G. PLANTINGS REQUIRED FOR A CERTIFICATE OF OCCUPANCY SHALL BE PROVIDED DURING THE NEXT APPROPRIATE SEASON AT THE MUNICIPALITY'S DISCRETION. CONTRACTOR SHOULD CONTACT APPROVING AGENCY FOR POTENTIAL SUBSTITUTIONS. H. FURTHERMORE, THE FOLLOWING TREE VARIETIES ARE UNUSUALLY SUSCEPTIBLE TO WINTER DAMAGE. WITH TRANSPLANT SHOCK AND THE SEASONAL LACK OF NITROGEN AVAILABILITY, THE RISK OF PLANT DEATH IS GREATLY INCREASED. IT IS NOT RECOMMENDED THAT THESE SPECIES BE PLANTED DURING THE FALL PLANTING SEASON: ACER RUBRUM PLATANUS X ACERIFOLIA BETULAVARIETIES POPULOUS VARIETIES CARPINUS VARIETIES PRUNUS VARIETIES CRATAEGUS VARIETIES PYRUS VARIETIES KOELREUTERIA QUERCUS VARIETIES LIQUIDAMBERSTYRACIFLUA TILIATOMENTOSA LIRIODENDRONTULIPIFERA ZELKOVA VARIETIES I. PLANTING PITS SHALL BE DUG WITH LEVEL BOTTOMS, WITH THE WIDTH TWICE THE DIAMETER OF ROOT BALL. THE ROOT BALL SHALL REST ON UNDISTURBED GRADE. EACH PLANT PIT SHALL BE BACKFILLED IN LAYERS WITH THE FOLLOWING PREPARED SOIL MIXED THOROUGHLY: • 1 PART PEAT MOSS • 1 PART COMPOSTED COW MANURE BY VOLUME • 3 PARTS TOPSOIL BY VOLUME • 21 GRAMS'AGRIFORM' PLANTING TABLETS (OR APPROVED EQUAL) AS FOLLOWS: A) 2 TABLETS PER 1 GALLON PLANT B) 3 TABLETS PER 5 GALLON PLANT C) 4 TABLETS PER 15 GALLON PLANT D) LARGER PLANTS: 2 TABLETS PER Y2' CALIPER OF TRUNK J. FILL PREPARED SOIL AROUND BALL OF PLANT HALF -WAY AND INSERT PLANT TABLETS. COMPLETE BACKFILL AND WATER THOROUGHLY. K. ALL PLANTS SHALL BE PLANTED SO THAT THE TOP OF THE ROOT BALL, THE POINT AT WHICH THE ROOT FLARE BEGINS, IS SET AT GROUND LEVEL AND IN THE CENTER OF THE PIT. NO SOIL IS TO BE PLACED DIRECTLY ON TOP OF THE ROOT BALL. L. ALL PROPOSED TREES DIRECTLY ADJACENT TO WALKWAYS OR DRIVEWAYS SHALL BE PRUNED AND MAINTAINED TO A MINIMUM BRANCHING HEIGHT OF 7' FROM GRADE. M. GROUND COVER AREAS SHALL RECEIVE A Y4' LAYER OF HUMUS RAKED INTO THE TOP 1" OF PREPARED SOIL PRIOR TO PLANTING. ALL GROUND COVER AREAS SHALL BE WEEDED AND TREATED WITH A PRE -EMERGENT CHEMICAL AS PER MANUFACTURER'S RECOMMENDATION. N. NO PLANT, EXCEPT GROUND COVERS, GRASSES OR VINES, SHALL BE PLANTED LESS THAN TWO FEET (2') FROM EXISTING STRUCTURES AND SIDEWALKS. O. ALL PLANTING AREAS AND PLANTING PITS SHALL BE MULCHED AS SPECIFIED HEREIN TO FILL THE ENTIRE BED AREA OR SAUCER. NO MULCH IS TO TOUCH THE TRUNK OF THE TREE OR SHRUB. P. ALL PLANTING AREAS SHALL BE WATERED IMMEDIATELY UPON INSTALLATION IN ACCORDANCE WITH THE WATERING SPECIFICATIONS AS LISTED HEREIN. 10. TRANSPLANTING (WHEN REQUIRED) A. ALL TRANSPLANTS SHALL BE DUG WITH INTACT ROOT BALLS CAPABLE OF SUSTAINING THE PLANT. B. IF PLANTS ARE TO BE STOCKPILED BEFORE REPLANTING, THEY SHALL BE HEALED IN WITH MULCH OR SOIL, ADEQUATELY WATERED AND PROTECTED FROM EXTREME HEAT, SUN AND WIND. C. PLANTS SHALL NOT BE DUG FOR TRANSPLANTING BETWEEN APRIL 10 AND JUNE 30. D. UPON REPLANTING, BACKFILL SOIL SHALL BE AMENDED WITH FERTILIZER AND ROOT GROWTH HORMONE. E. TRANSPLANTS SHALL BE GUARANTEED FOR THE LENGTH OF THE GUARANTEE PERIOD SPECIFIED HEREIN. F. IF TRANSPLANTS DIE, SHRUBS AND TREES LESS THAN SIX INCHES (6") DBH SHALL BE REPLACED IN KIND. TREES GREATER THAN SIX INCHES (6") DBH MAY BE REQUIRED TO BE REPLACED IN ACCORDANCE WITH THE MUNICIPALITY'S TREE REPLACEMENT GUIDELINES. 11. WATERING A. NEW PLANTINGS OR LAWN AREAS SHALL BE ADEQUATELY IRRIGATED BEGINNING IMMEDIATELY AFTER PLANTING. WATER SHALL BE APPLIED TO EACH TREE AND SHRUB IN SUCH MANNER AS NOT TO DISTURB BACKFILL AND TO THE EXTENT THAT ALL MATERIALS IN THE PLANTING HOLE ARE THOROUGHLY SATURATED. WATERING SHALL CONTINUE AT LEAST UNTIL PLANTS ARE ESTABLISHED. B. SITE OWNER SHALL PROVIDE WATER IF AVAILABLE ON SITE AT TIME OF PLANTING. IF WATER IS NOT AVAILABLE ON SITE, CONTRACTOR SHALL SUPPLY ALL NECESSARY WATER. THE USE OF WATERING BAGS IS RECOMMENDED FOR ALL NEWLY PLANTED TREES. C. IF AN IRRIGATION SYSTEM HAS BEEN INSTALLED ON THE SITE, IT SHALL BE USED TO WATER PROPOSED PLANT MATERIAL, BUT ANY FAILURE OF THE SYSTEM DOES NOT ELIMINATE THE CONTRACTOR'S RESPONSIBILITY OF MAINTAINING THE DESIRED MOISTURE LEVEL FOR VIGOROUS, HEALTHY GROWTH. 12. GUARANTEE A. THE LANDSCAPE CONTRACTOR SHALL GUARANTEE ALL PLANTS FOR A PERIOD OF ONE (1) YEAR FROM APPROVAL OF LANDSCAPE INSTALLATION BY THE APPROVING AGENCY. CONTRACTOR SHALL SUPPLY THE OWNER WITH A MAINTENANCE BOND FOR TEN PERCENT (10%) OF THE VALUE OF THE LANDSCAPE INSTALLATION WHICH WILL BE RELEASED AT THE CONCLUSION OF THE GUARANTEE PERIOD AND WHEN A FINAL INSPECTION HAS BEEN COMPLETED AND APPROVED BY THE OWNER OR AUTHORIZED REPRESENTATIVE. B. ANY DEAD OR DYING PLANT MATERIAL SHALL BE REPLACED FOR THE LENGTH OF THE GUARANTEE PERIOD. REPLACEMENT OF PLANT MATERIAL SHALL BE CONDUCTED AT THE FIRST SUCCEEDING PLANTING SEASON. ANY DEBRIS SHALL BE DISPOSED OF OFF -SITE, WITHOUT EXCEPTION. C. TREES AND SHRUBS SHALL BE MAINTAINED BY THE CONTRACTOR DURING CONSTRUCTION AND THROUGHOUT THE 90 DAY MAINTENANCE PERIOD AS SPECIFIED HEREIN. CULTIVATION, WEEDING, WATERING AND THE PREVENTATIVE TREATMENTS SHALL BE PERFORMED AS NECESSARY TO KEEP PLANT MATERIAL IN GOOD CONDITION AND FREE OF INSECTS AND DISEASE. D. LAWNS SHALL BE MAINTAINED THROUGH WATERING, FERTILIZING, WEEDING, MOWING, TRIMMING AND OTHER OPERATIONS SUCH AS ROLLING, REGARDING AND REPLANTING AS REQUIRED TO ESTABLISH A SMOOTH, ACCEPTABLE LAWN, FREE OF ERODED OR BARE AREAS. 13. CLEANUP A. UPON THE COMPLETION OF ALL LANDSCAPE INSTALLATION AND BEFORE THE FINAL ACCEPTANCE, THE CONTRACTOR SHALL REMOVE ALL UNUSED MATERIALS, EQUIPMENT AND DEBRIS FROM THE SITE. ALL PAVED AREAS ARE TO BE CLEANED. B. THE SITE SHALL BE CLEANED AND LEFT IN A NEAT AND ACCEPTABLE CONDITION AS APPROVED BY THE OWNER OR AUTHORIZED REPRESENTATIVE. DO NOT ST) WRAF ONLY TREES WITH ONE MAIN LEADER SHALL BE PURCHASED. DO NOT PRUNE TREE AT PLANTING UNLESS DIRECTED TO BY PROJECT LANDSCAPE ARCHITECT FOLD BURLAP AWAY FROM TOP OF ROOT BALL PREPARE WIDTH OF `e SET ROOT BALL FLUSH TO GRADE OR PLANTING HOLE 6 FT SEVERAL INCHES HIGHER IN OR TWICE THE WIDTH POORLY DRAINING SOILS. OF THE ROOT BALL; WHICHEVER IS 4" BUILT-UP EARTH SAUCER GREATER 3" THICK LAYER OF DARK BROWN DOUBLE SHREDDED PREPARED SOIL FOR HARDWOOD MULCH TREES 1 PART PEAT MOSS 1 BEFORE PLANTING ADD 3 TO 4" PART COW MANURE 3 PARTS TOPSOIL OF WELL -COMPOSTED LEAVES OR RECYCLED YARD WASTE TO C BED AND TILL INTO TOP 6" OF -I -III- I I -III -I PREPARED SOIL. 11 I=III = +.. -I I=I I I=I I I- UNDISTURBEI— _— 4-6" DEEPER THAN ROOT BALL SUBGRADE =I -III—III—III—III= —III—III-I I-� REMOVE THE TOP 1/3 OF THE WIRE BASKET —III=III— I— IF PRESENT. ANY AND ALL TWINE SHALL BE DIG WIDE, SHALLOW HOLE REMOVED FROM THE TREE BEFORE WITH TAMPED SIDES BACKFILLING. BURLAP SHALL BE FOLDED TAMP SOIL SOLIDLY AROUND BACK INTO PLANTING HOLE BASE OF ROOT BALL PAD IN BOTTOM OF HOLE REFERENCE: ARCHITECTURAL GRAPHIC STANDARDS 1998 CUMULATIVE SUPPLEMENT. JEV EIRGIR EJEN TIRXaEaE PLANTING DETAIL NOT TO SCALE ONLY TREES WITH ONE MAIN LEADER 0 o 0 0 ° SHALL BE PURCHASED. DO NOT PRUNE o°o ° o TREE AT PLANTING UNLESS DIRECTED TO BY PROJECT LANDSCAPE ARCHITECT DO NOT STAKEo ° OR WRAP TRUNK ° FOLD BURLAP AWAY FROM PREPARE WIDTH OF ° °o o TOP OF ROOT BALL PLANTING HOLE 6 FT OR TWICE THE WIDTH OF SET ROOT BALL FLUSH TO GRADE ° o 0o THE ROOT BALL; o ° OR SEVERAL INCHES HIGHER IN WHICHEVER IS GREATER o POORLY DRAINING SOILS. 4" BUILT-UP EARTH SAUCER PREPARED SOIL FOR TREES 1 PART PEAT MOSS 3" THICK LAYER OF DARK BROWN DOUBLE 1 PART COW MANURE SHREDDED HARDWOOD MULCH 3 PARTS TOPSOIL BEFORE PLANTING ADD 3 TO 4" OF WELL -COMPOSTED LEAVES OR UNDISTURBE RECYCLED YARD WASTE TO BED SUBGRADE AND TILL INTO TOP 6" OF I- I I -I 1= I 1=III=III- PREPARED SOIL. 4-6" DEEPER THAN ROOT BALL =III=I I — __—_— — DIG WIDE, SHALLOW HOLE —III-III—III—III—III= I I REMOVE THE TOP 1/3 OF THE WIRE BASKET IF -III—III WITH TAMPED SIDES "—III=III— I— PRESENT. ANY AND ALL TWINE SHALL BE REMOVED FROM THE TREE BEFORE TAMP SOIL SOLIDLY BACKFILLING. BURLAP SHALL BE FOLDED BACK AROUND BASE OF INTO PLANTING HOLE ROOT BALL SET ROOT BALL ON FIRM PAD IN BOTTOM OF HOLE REFERENCE: ARCHITECTURAL GRAPHIC STANDARDS 1998 CUMULATIVE SUPPLEMENT. DECIDUOUS TIRXJEJE PLANTING IL DETAIL NOT TO SCALE PLANT SHALL TRANSPLANTED AT THE S/ GRADE AS IT BORE IN - NURSERY PLOT PRIOR BALLING AND BURLAPPI PLANTING MIX: 1 PART PEAT MOSS 1 PART COW MANURE 3 PARTS TOPSOIL PLANTING MIXTURE WILL CHANGE WITH SOIL CONDITIONS BEFORE PLANTING, ADD 3 TO OF WELL -COMPOSTED LEAVE AND RECYCLED YARD WASI TO BED AND TILL INTO TOP OF PREPARED SC REMOVE THE TOP 1/3 OF TF WIRE BASKET IF PRESENT. Al' AND ALL TWINE SHALL I REMOVED FROM THE SHRL BEFORE BACKFILLING. BURL/ SHALL BE FOLDED BACK INTO PLANTING HOLE REFERENCE: ARCHITECTURAL GRAPHIC STANDARDS 1998 CUMULATIVE SUPPLEMENT DECIDUOUS AND aEV EIRGIR EaEN S H IRXUBD PSI ANTING DETAIL NOT TO SCALE INCORPORATE 2" OF PEAT INTO 6" OF PLANTING MIXTURE, AS SPECIFIED 3" THICK LAYER OF DARK BROWN DOUBLE SHREDDED HARDWOOD MULCH FINISHED GRADE CONTAINER -GROWN JBS, USE FINGER OR _L HAND TOOLS TO PULL ROOTS OUT OF THE OUTER :R OF POTTING SOIL; THEN OR PULL APART ANY TS THAT CIRCLE THE METER OF THE CONTAINER TICK LAYER OF DARK VVN DOUBLE EDDED HARDWOOD :�H >HED GRADE ;E SHRUB ON SOIL IN FOM OF HOLE. STURBED 3RADE SURFACE ROUGHENED TO BIND WITH NEW SOIL. PLANT MATERIAL SPACED AS SPECIFIED. SEE LANDSCAPE SCHEDULE FOR PROPOSED SPACING. MINIMUM 6" TOPSOIL f�1 .: iEXISTING SUBSOIL -III=III=1111;1111 III ' l l l� �� l—I � I I � I =III=III== =III —III —I TYPICAL PERENNIAL AND GROUND COVER PLANTING D= PROPOSED ON CENTER (O.C.) SPACING SEE LANDSCAPE SCHEDULE FOR FOR REQUIRED SPACING TYPICAL PERENNIAL AND GROUND COVER SPACING & LAYOUT P EIR ENNIAA/GIROCC ND COV EIRPLANTING DETAIL NOT TO SCALE NOTE: TREE STAKING TO BE REMOVED AFTER 2 GROWING SEASONS DO NOT WRAP TRUNK REINFORCED RUBBER HOSE (1/2" DIA.) 12 GAUGE GALVANIZED WIRE GUYS TWISTED 2" DIA. HARDWOOD STAKES 2/3 TREE HT. 2 PER TREE EXISTING GRADE PREPARED SOIL FOR TREES 1 PART PEAT MOSS 1 PART COW MANURE 3 PARTS TOPSOIL `WN TAMP SOIL SOLIDLY AROUND BASE OF ROOT BALL NLY TREES WITH ONE MAIN LEADER SHALL BE PURCHASED. DO NOT PRUNE TREE AT PLANTING UNLESS DIRECTED >° TO BY PROJECT LANDSCAPE ARCHITECT SET ROOT BALL FLUSH TO GRADE ,,,,—SET SEVERAL INCHES HIGHER IN POORLY DRAINING SOILS. 3" THICK LAYER OF DARK BROWN DOUBLE SHREDDED HARDWOOD MULCH !lI�:I111��11��G1 i::�9GlIL•l� 7 BEFORE PLANTING ADD 3 TO 4" OF WELL -COMPOSTED LEAVES OR RECYCLED YARD WASTE TO BED AND TILL INTO TOP 6" OF PREPARED SOIL. REMOVE THE TOP 1/3 OF THE WIRE BASKET IF PRESENT. ANY AND ALL TWINE SHALL BE REMOVED FROM THE TREE BEFORE BACKFILLING. BURLAP SHALL BE FOLDED BACK INTO PLANTING HOLE SET ROOT BALL ON FIRM PAD IN BOTTOM OF HOLE TIRXaEaE PLANTING ON SLOPE DETAIL NOT TO SCALE OWNER MAINTENANCE RESPONSIBILITIES UPON OWNER'S (OR OWNER CONTRACTOR'S) COMPLETION OF LANDSCAPING WORK, THE OWNER IS FULLY RESPONSIBLE FOR ALL FUTURE MAINTENANCE, CARE, UPKEEP, WATERING, AND TRIMMING OF ALL INSTALLED VEGETATION, PLANTS, TREE, BUSHES, SHRUBS, GRASSES, GRASS, ORNAMENTAL PLANTS AND FLOWERS, FLOWERS, GROUND COVER, AND LANDSCAPING, INCLUDING ALL LANDSCAPE ISLANDS AND AREAS ADJACENT OR PART OF THE LANDSCAPED AREAS. THIS RESPONSIBILITY INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING: • TREES ADJACENT TO WALKWAYS AND AREAS OF PEDESTRIAN TRAFFIC MUST BE MAINTAINED TO ASSURE THAT ANY BRANCHES MUST BE LIMBED UP TO A CLEARANCE HEIGHT OF 7 FT. (FROM ALL PEDESTRIAN SURFACES) OR PRUNED BACKTO AVOID ANY INTERFERENCE WITH THE TYPICAL PATH OF TRAVEL. • TREES WITHIN VEHICULAR SIGHT LINES, AS ILLUSTRATED ON THE LANDSCAPE PLAN, ARE TO BE TRIMMED TO A CLEARANCE HEIGHT OF 7 FT. (FROM ALL PAVED, TRAVELED SURFACES), OR AS OTHERWISE INDICATED ON THE PLANS. • VEGETATIVE GROUND COVER, SHRUBS AND ORNAMENTAL PLANTS AND GRASSES MUST BE TRIMMED SO THAT NO PORTION OF THE PLANT EXCEEDS 30 INCHES ABOVE GRADE (OF ALL PAVED, TRAVEL SURFACES) ALONG AND WITHIN THE SIGHT LINES OF PARKING LOTS AND INGRESS -EGRESS WAYS. • FALLEN PLANT FLOWERS, FRUIT, SEEDS AND DEBRIS DROPPINGS ARE TO BE REMOVED IMMEDIATELY FROM VEHICULAR AND PEDESTRIAN TRAFFIC AREAS TO PREVENT TRIPPING, SLIPPING OR ANY OTHER HAZARDS. THESE REQUIREMENTS DO NOT AFFECT THE PLANT LIFE GUARANTEES THE LANDSCAPE CONTRACTOR IS REQUIRED TO PROVIDE. a � C� ud U `" b ® c � REVISIONS REV DATE COMMENT BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD 1. D.: NCC18211OSDO '--PROJECT ARKA HEIGHTS FOR ARKA HEIGHTS, LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY r OT01 o OTI-IT ��� ]ENGHN]EIEI HNG NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)30hierEng.com CIAROSC ,,, P :uj 2102 DnilSiu\NG\\\\ \ SHEET TITLE: LANDSCAPING DETAILS SHEET NUMBER: C-704 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110SDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:59 PM LAST SAVED BY: MMOORE EX. POLE SIGNAGJE AND STRIPING PLAN c� 83 ti 5 PROP. T SIDEWALK 5 PROP 5' SIDEWALK ALONG OLD CHARLOTTE HWY — — — — — — — — — — — — — — — — — — — — — PROP. 10' X 70' NCDOT PROP. 6 SIDEWALK ° SIGHT TRIANGLE 1 ° ti ti PUBLIC ROW 30' FROM ROAD CENTERLINE EX. TELEPHONE PROP ROW EX. FH EX. GE OF EX. POLE PEDESTAL PAVE / --,BHBH LOD- 4" WIDE WHITE SOLID LANE LINE (PER 1p EX. TELE LOD LOD LOD CV M N p fl -- 2/3A =133 0 100' TAP EX. EDGE OFF 4" DOUBLE YELLOW LINES WITH PAVEMENT PROP. LEFT TURN LANE (100' STRIPED MEDIAN PER NCDOT EX. POLE 4" WIDE 3' 97SP WHITE MINI -SKIP STORAGE, 100' TAPER) PER STD 1205.09 F-� NCDOT REQUIREMENTS TELE 100, LEFT TURN SYMBOL (NCDOT- STD 1205.08) SPACED PER NCDOT 1205.05 EXISTING RIGHT TURN LANE. STRIPING NOT AVAILABLE AT TIME OF SURVEY $TO j9R pf co PROP. ADA CURB RAMP I (TYP•) PROP. T SIDEWALK I— — —_4 -° — — — — — — — — — — — — — — — — — — — °1 N PROP. ADA RAMP NCDOT STD 848.05 PROP. 5' SIDEWALK POLE - — H OH AF OH—OH- 12LD CHARLOTTE HWY. � WHITE EDGE LINE 1' OFF EOP (TYP.) N53°1 V24" W 919.83' N —EX. C/L POSTED SPEED: 45 MPH DESIGN SPEED: 50 MPH : F_F.3IY•111►1H1: Ia0r11V►1r_1►1: a.1: &I CC] ►DM_1 I 1,111i* � WIDTH OF SHIFT, W = 4' APPROACH TAPER, A (REQUIRED) = 200' DECELERATION LENGTH, D = 150' TAPER LENGTH = 100' STORAGE PROVIDED = 100' ALL FIXED OBJECTS NOT CONSIDERED BREAKAWAY MUST BE REMOVED FROM CLEAR RECOVERY ZONE - MEASURED FROM THE EDGE OF PAVEMENT FOR SECTIONS WITHOUT CURB AND GUTTER ON BONTERRA VILLAGE WAY (POSTED SPEED LIMIT 45 MPH) (SEE CROSS SECTIONS FOR EXACT WIDTH). OWNER IS RESPONSIBLE TO REMOVE EXISTING TREES AND/OR RELOCATE OVERHEAD UTILITY POLES LOCATED WITHIN CLEAR ZONE. PERMISSION FROM ADJACENT PROPERTY OWNER IS REQUIRED PRIOR TO TREE REMOVAL/POLE RELOCATION FROM ADJACENT PROPERTY. IF TREES ARE ONLY TRIMMED AND NOT FULLY REMOVED AN EASEMENT WILL BE REQUIRED IN ORDER TO KEEP CLEAR ZONE OBSTRUCTION FREE. CONTRACTOR AND DEVELOPER TO COORDINATE THE LOCATION OF THE RELOCATED POLE(S) WITH UNION POWER COOPERATIVE. POWER POLES MUST BE RELOCATED TO MEET MINIMUM CLEAR RECOVERY. CONTRACTOR TO COORDINATE IMPACTS TO EXISTING DRIVEWAYS WITH OWNERS. DRIVEWAYS TO BE BROUGHT TO PROPOSED GRADE WITHIN PROPOSED GRADING LIMITS. 0 21 30 15 7.5 0 30 1 "= 30' 101 REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD I.D.: NCC18211ORD0 PROJECT: ARKA HEIGHTS FOR ARKA HEIGHTS, LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY DD O� L�� ]ENGIINIEEKIING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)30hierEng.com rSHEET TITLE: STRIPING AND S1IGNAGE PLAN SHEET NUMBER: C-801 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211ORDO.DWG PRINTED BY: SFARMARTINO 12.17.19 @ 8:17 AM LAST SAVED BY: SMITCH ELL Cl� CONCRETE CURB & GUTTER CURB AND GUTTER SPILL CURB TRANSITION CURB DEPRESSED CURB AND GUTTER r 1 0+50 GRADING LEGEND EXISTING GRADE PROPOSED GRADE FUTURE GRADE PAVEMENT LEGEND CONCRETE SIDEWALK NCDOT PAVEMENT SECTION NCDOT MILL AND OVERLAY 0+10 Cl� 0 21 30 15 7.5 0 30 1 "= 30' REVISIONS REV DATE COMMENT BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD I.D.: NCC182110RD0 PROJECT: ARKA HEIGHTS Imm ARKA HEIGHTS, LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY 0-1 � ��� ENGINEERING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)30hierEng.com o oFESS /�°°°° '� '�y ° o , 0 o o o °°o'c"GINE�e,°° ,,��: °°° °° Flk112119 \ SHEET TITLE: PAVEMENT SHEET NUMBER: H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211ORDO.DWG PRINTED BY: MMOO RE 12.16.19 @ 5:59 PM LAST SAVED BY: SM ITCH ELL I I I I I � I I \s \ -- --- - - - - - - - - -------------- - - - - - ------------ --I - - - - - - - - - LLLLJ 1�k ------------ --------------- ------ ---------------------- `------ -- - --------- ------ ----- - — — ii---------' - ---- --- ------ ----- ---------------74117'�t)-_____ ao� ao� ao� N53'?t24"lA�_��9.83' — — 11 — — — — — .-�+50 _ a-------553°(t-7'D5" nn 0+50 1 � - -_ 00 2+0011 _--------------- 8+00 � M M �� _ m _ ---- 2+50 � -- - ------ ----- ----- — __- T TUR NCDOT INTERSEC 10 555 SIG T DISTANCE FOR RIGHT TURN AT NCDOT INTERSECTION TYP E T YP N ) / _-- TANC Al j EFOR / '- — — — — — — — — — — — — � / — — — — — — — — — — — — — — — — — — — — _ E NTRANCE B ENTRANCE A I I i A' I 0 o VIA . rf ♦ II I ,t 1 �♦ I I 1 — 1 ♦ �� ♦ / : `' \ ' 208.43' (tie) - N530 13 22 W 17. jry .' 680 670 660 480' 0 J 555' _ E 0131 M z EXISTING GRADE P ROPOSED GRADE EXISTING GRADE 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 SIGHT DISTANCE PROFILE - ENTRANCE A SCALE: V= 60' HORIZONTAL 1 "= 6 ' VERTICAL 680 670 660 OWNER IS RESPONSIBLE TO REMOVE EXISTING TREES/OBSTRUCTIONS LOCATED WITHIN SIGHT LINE. PERMISSION FROM ADJACENT PROPERTY OWNER IS REQUIRED PRIOR TO TREE/OBSTRUCTIONS REMOVAL FROM ADJACENT PROPERTY. IF TREES ARE ONLY TRIMMED AND NOT FULLY REMOVED AN EASEMENT WILL BE REQUIRED IN ORDER TO MAINTAIN CLEAR SIGHT DISTANCE. MIN .0 3 0 15 0 .1 REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD I.D.: NCC18211ORD0 PROJECT: ARKA HEIGHTS FOR ARKA HEIGHTS, LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY o O� ��� ]ENGINEERING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)30hierEng.com SHEET TITLE: SIGHT DISTANCE PROFILE SHEET NUMBER H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211ORDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:59 PM LAST SAVED BY: SMITCHELL 1 1 i ♦_ - - - - - - ' ----- 664#------ ------ \-------- —--------------_ — 74,07' te-F ------ 1+00 1+50 2+00 2+50 3+00 38-- 555SIGHT DISTANCE FOR LEFT TURN AT NCDOT INTERSECTION P) �/ \ 1 rn o — — (O �jS•L 4 7 oz T. iSb3H10 A9) U '6'66 670 660 d9l—99£-60 •0/ -4/N - 1 _40d0-99£-60 •0/ Yf/1 �ess"'-/'_---___�l_— - ------------ .E- - - —66— - - - l % 0i7end - 6001-�JS) g+50 ao, ,09 __--N-5S-Tt'24=�_.919.�T 9+0o ```� +00 667 (TYP , - ----- -------- 6GFr66� �s66•« ` _ _ M LEFT TURN AT NCDOT INTERSECTION — — �7 = ' 4 'SIG .\ _ --_ is �:.L• .a .."`. .:. •. .0L --.. — ------------ ' —.. T ANCE B ' ENTRANCE A Y913S , 0,7 owl i % �7 i '�� 0.■o�0.■C ��- �� OPEN� i 555' 480' 0 J 0131 E MZ _ EXISTING GRADE EXISTING GRADE (FROM G1, DATA) EXISTING GRADE PROPOSE GRADE 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 SIGHT DISTANCE PROFILE - ENTRANCE B SCALE: 1 "= 60 ' HORIZONTAL 1 "= 6 ' VERTICAL 670 660 OWNER IS RESPONSIBLE TO REMOVE EXISTING TREES/OBSTRUCTIONS LOCATED WITHIN SIGHT LINE. PERMISSION FROM ADJACENT PROPERTY OWNER IS REQUIRED PRIOR TO TREE/OBSTRUCTIONS REMOVAL FROM ADJACENT PROPERTY. IF TREES ARE ONLY TRIMMED AND NOT FULLY REMOVED AN EASEMENT WILL BE REQUIRED IN ORDER TO MAINTAIN CLEAR SIGHT DISTANCE. MIN .0 3 0 15 0 .1 �_ m 101 REVISIONS REV DATE COMMENT BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD I.D.: NCC18211ORDO PROJECT: ARKA HEIGHTS FOR ARKA HEIGHTS, LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY o 0TL7 ��� ENGINEERING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@)30hierEng.com SHEET TITLE: SIGHT DISTANCE PROFILE SHEET NUMBER H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211ORDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:59 PM LAST SAVED BY: SMITCHELL H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110RDO.DWG PRINTED BY: MMOO RE 12.16.19 @ 5:59 PM LAST SAVED BY: SM ITCH ELL H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC182110RDO.DWG PRINTED BY: MMOO RE 12.16.19 @ 5:59 PM LAST SAVED BY: SM ITCH ELL S� 6" E�••� #4 BARS "V" I 6" @ EQUAL SPACES 1 /2 " 3" R -co _ W R U Q �cn m ? w v o it w co a PLAN OF TOP SLAB "W" BARS SECTION R-R 6" 1 /211 In Lu Q a U) CO m Q w v o w co SECTION S-S #4 BAR N "6- DOWEL �-� 6'- 0" PLAN CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES TOP USE ON FLAT ELEV. EXPANSION JOINT 6 GRADES 2% AND UNDER 7 4 0 I II i 3, O„ DEPRESSED GUTTER LINE EXPANSION JOINT-):::3:: 00 ELEVATION NORMAL CURB AND GUTTER ON LIGHT GRADES NORMAL GUTTER LINE EXPANSION JOINT 6" 8" TOP USE ON GRADES OVER 2% ELEV. I - 4 DEPRESSED GUTTER LINE 10" I R'-D" EXPANSION JOINT) 1 0 ICI MAX. ELEVATION NORMAL CURB AND GUTTER ON STEEP GRADES MINIMUM DIMENSIONS AND QUANTITIES FOR CONCRETE CATCH BASIN(BASED ON MIN. HEIGHT, H, WITH NO RISER) DIMENSIONS OF BOX AND PIPE COVER DIMENSION CU.YDS. CONC. IN BOX DEDUCTIONS ONE PIPE PIPE SPAN WIDTH WIDTH SPAN MIN. HEIGHT BARS-U NO. LENGTH BARS-V NO. LENGTH BARS-W NO. LENGTH TOTAL LBS. TOP SLAB BOTTOM SLAB TOT.CONC. FOR MINIMUM HEIGHT H D A B C G H E F C.M. R. C. 12" 3'-0" 2'-2" 2'-9" 0.235 0.772 0.015 0.026 151, 3'-0" 2'-2" 3'-0° 0.235 0.829 0.023 0.036 18" 3'-0" 2'-2" 3'-3" 0.235 0.887 0.033 0.049 24" 3'-0" 2'-2" 3'-9" 0.235 1.001 0.059 0.085 30" 1 3'-0" 2'-2" 1 3'-4" 4'-3" V-2" 4'-0" 4 V-5" 2 3'-9" 3 3'-9" 39 0.123 0.321 1.433 0.092 0.127 36" 3'-0" 2'-2" 3'-10" 4'-9" 1'-8" 4'-0" 4 1'-11" 3 3'-9" 3 3'-9" 43 0.161 0.358 1.714 0.132 0.178 42" 3'-0" 2'-2" 4'-5" 5'-3° V-5" 3'-2" 4 1'-8" 2 2'-11" 3 2'-11" 32 0.112 0.318 1.738 0.180 0.243 48" 3'-0" 2'-2" 5'-0" 5'-9" 2'-0" 3'-2" 4 2'-3" 3 2'-11" 3 2'-11" 35 0.145 0.352 2.052 0.235 0.317 54" 3'-0" 2'-2" 5'-7" 6'-3° 2'-7" 3'-2" 4 2'-10" 5 2'-11" 3 2'_11" 41 0.180 0.386 2.387 0.297 0.401 BACK OF CURB - PLAN t SECTION Y-Y RISER HT. VARIES 6" o �o WHERE 30" TO 36" PIPE IS USED RISER HT. WHERE 42" TO 54" PIPE IS USED DETAIL SHOWING METHOD OF RISER CONSTRUCTION SECTION X-X z 00 I__q} QQ Ho~CM:U L L J O O CL C/) _ LuQzLL= QU=OO-1-1 f- (�HLLOJ 0 0 U)cr Z H � H I Lu Q O Z LL N (D U) Zmw CL Q 1--1 _ _ 0 O LO Iz Q v � Q W IH O W - } � N Q � T Q Z Q 0 O 0 SHEET 2 OF 2 * RISER HAS .228 CUBIC YARDS OF CONCRETE PER FOOT HEIGHT 840.02 GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL CATCH BASINS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. USE TYPE "E", "F" AND "G" GRATES UNLESS OTHERWISE INDICATED. FOR 8'-0" IN HEIGHT OR LESS USE 6" WALLS AND BOTTOM SLAB. OVER 8'-0" TO 16'-0" IN HEIGHT USE 8" WALLS AND BOTTOM SLAB. ADJUST QUANTITIES ACCORDINGLY. CONSTRUCT WITH PIPE CROWNS MATCHING. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. SEE STD.NO. 840.03 STEPS - STD. NO. 840.66 TOP ELEVATION 6 B T} ° E-�I I o. vp = 6" ° C 6" a. v D o 0 0' o� p. 6,� o' T ..D T SECTION J-J WHERE 30" TO 36" PIPE IS USED SEE NOTE ul B aj o. aj PLAN TOP ELEVATION STEPS - STD. NO. 840.66 E --I o' 0 ' 6" G 6" D to SECTION M-M WHERE 42" TO 54" PIPE IS USED m �1 A p pi o: o' w 1 00 0 PLAN " RAD. 6" 2'-Orr 3" RAD. 1/8" RAD o ° • o' . p .. CD v v . p• p• 2 - 6 " �I 10 2'-6" CURB AND GUTTER 4'-011 PR /a" RAD. 911 9 r, 3/ rr RAD . 1/g" RAD . N p. I I 13/4" RAD. 1'-6" 1'-6" CURB AND GUTTER 2" RAD. PAVEMENT RAD. SURFACE 440 p ; ° •o CO °'�:.. 1r, N r '°• 8 rr 8" X 12" OR 18" CONCRETE CURB PAVEMENT z O 1/g" RAD. SURFACE 3 Q Q�� FZ-1�CV 0 LL _J 1-I 00co=z .o •' wQz� p:' 2,r ac.�CC0� - r r 13//4 RAD. 1--1 �I=-�o J o. 0 CO rr 9 ap 0- 9" X 12" OR 18" r o 0 CONCRETE CURB 2'-0" 2r 0" EDGE OF PAVEMENT 2" RAD. 2'-0" 8" it Or, 1r Or, 1/8RADIUS >�/ 12 'O': po'6riF,�7::°•.po °'.7rrrrp .' o.• p .' o p 7rr 44� :9:':;.:::, /':rr'. p 6 o •... o .. ::;•:'::°: 6..MIN:' 7 O LL LLI 8„ 0 H GC EXPRESSWAY GUTTER SHOULDER BERM GUTTER z H W 8" X 6" MEDIAN CURB VALLEY GUTTER Q � � SECTION VIEW OF CURBS OR CURBS AND GUTTERS m � OC otf FILL 3/8" x 1" DEEP Qca GENERAL NOTES: GROOVED OR S4WN z V ca -PLACE CONTRACTION JOINTS AT 10' INTERVALS, EXCEPT THAT JOINT WITH Jz W m A 15' SPACING MAY BE USED WHEN A MACHINE IS USED OR WHEN SATISFACTORY SUPPORT FOR THE FACE FORM CAN BE OBTAINED SEALER JOINT SEALER rA W WITHOUT THE USE OF TEMPLATES AT 10' INTERVALS. 1/8" RAD. GUTTER -JOINT SPACING MAY BE ALTERED IF REQUIRED BY THE ENGINEER. a. 1/g RAD.PAVEMENT SURFACE V Z -CONTRACTION JOINTS MAY BE INSTALLED WITH THE USE OF SURFACE 0 G Q TEMPLATES OR FORMED BY OTHER APPROVED METHODS. Ir ;°•: :9.*Q.•• R. . Q cV O CONSTRUCT NON -TEMPLATE FORMED JOINTS A MIN. OF 1 %2 DEEP. .a �'..° '.a .° p° ° ":• ' ' ' 'p" • p :. �, p' : o' p r °C -FILL ALL CONSTRUCTION JOINTS, EXCEPT IN 8"x6" MEDIAN CURB, o°.o. v •°' v '• °' WITH JOINT FILLER AND SEALER. PROPOSED '''pCURB & GUTTERPROP.JOINT FILLER -SPACE EXPANSION JOINTS AT 90 INTERVALS AND ADJACENT TO PAVEMENT1/2 ALL RIGID OBJECTS. JOIN LONGITUDINAL JOINT TRANSVERSE EXPANSION JOINT IN CURB AND GUTTER SECTION VIEW OF JOINTS SHEET 1 of 3 846.01 1.5" S9.513 SURFACE COUtR 2.5" 119.0C JNTERNIENAT ! COURSE . Imo'. � Y.',-1 �',1-•.i -�.._! �' EkSE COLME 5" ASPHALT 8" ASPHALT BASE COURSE BASE COURSE NCDOT CURB & GU INST'ALLATiON DETAIL Z 00 H aQ Hp~C(='�U LL _J OOrn= wQQLL_ Q U cr O H I- H = Z LLI (n�LLOJ C)000 Z H 1 H 1 M O LL Z m (3 U) Z l.0 MaM a = Q � = hi tL Q I- LO Q �++ V CENTER LANE CLOSED 1 i W20-5 48" X 48" .5" ASPHALT SURFACE COURSE (S9.513) ASPHALT INTERMEDIATE COURSE (1-19.013) ASPHALT BASE COURSE (1325.013 OR C) COMPACTED SUBGRADE (PER GEOTECHNICAL REPORT AND NCDOT SPECS) NOTE. 1. FINAL DEPTH OF PAVEMENT SHALL BE PER NCDOT REVIEW AND AT A MINIMUM SHALL MATCH EXISTING PAVEMENT SECTION AS DETERMINED IN THE FIELD. 2. PATCHING AND LEVELING MAY BE REQUIRED PRIOR TO RESURFACING THE ROAD. NCDOT PAVEMENT SECTION NOT TO SCALE z Ocf) F-I aQ LL_J�1-IZ 00 co = Lu<<LL_ = QUIz0C-D CL-LLO-1 A 0cc cr 0 ((1) Z H 1 I>-1 00 11VVL 1 I %jiI L- LlIIVL IIVlIVtYlII V Q WITH 2-WAY TURN LANE Lu ALL OTHER DEVICES ARE THE SAME AS ABOVE y O = J � LL U A11 CENTER LANE CLOSED = Lu WORK AREA .�- 2-WAY TRAFFIC TAPER BUFFEF 50'-100' SPACE O GENERAL NOTES FOR FLAGGING OPERATIONS u 1- REFER TO RSD. 1101.11, SHEETS 1 & 4, FOR "L" DISTANCE AND SIGN SPACING. < 2- INSTALL LANE CLOSURES WITH THE TRAFFIC FLOW, BEGINNING WITH DEVICES ON THE W - UPSTREAM SIDE OF TRAFFIC. 3 REMOVER LANESILOSURES GAINST THE TRAFFIC FLOW, BEGINNING WITH DEVICES ON THE Q V r DOWNSTE OFZ AC. O 4- PLACE CONES THRU THE WORK AREA AT THE MAXIMUM SPACING EQUAL IN FEET TO 2 TIMES Q THE POSTED SPEED LIMIT. 00 5- EXTEND LANE CLOSURES AT THE BUFFER SPACE SUCH THAT STOPPING SIGHT DISTANCE IS PROVIDED TO THE FLAGGER (REFER TO RSD. 1101.11, SHEET 2). 6- DO NOT STOP TRAFFIC IN ANY ONE DIRECTION FOR MORE THAN 5 MINUTES AT A TIME. 7- DRUMS OR SKINNY DRUMS MAY BE USED IN LIEU OF CONES. REFER TO RSD. 1180.01 FOR SKINNY DRUM REQUIREMENTS. 8- USE FLAGGERS TO CONTROL TRAFFIC AT INTERSECTIONS AFFECTED BY THE LANE CLOSURE. SUPPLEMENT FLAGGERS LOCATED AT INTERSECTIONS WITH FLAGGER AHEAD SIGNS (W20-7a) PLACED APPROXIMATELY 250 FT. IN ADVANCE OF THE FLAGGER. FOR SIGNALIZED INTERSECTIONS PLACE SIGNALS IN THE FLASH MODE AND USE LAW ENFORCEMENT. 9- REFER TO THE CURRENT MUTCD FOR FLAGGER CONTROL, REQUIREMENTS, AND PROCEDURES. 10- DO NOT EXCEED A 1 MILE LANE CLOSURE LENGTH UNLESS OTHERWISE SHOWN IN THE TMP OR SHEET 1 OF 2 AS DIRECTED BY THE ENGINEER. 1840.021 W20-5 48" X 48" z Q . DOWN Q I L _J T STREAM W BUFFER TAPER Q 1 SPACE 100' Q QS O J O 11- IF VEHICLE QUEUES WILL REACH WITHIN 15' OF EITHER SIDE OF ACTIVE RAILROAD TRACKS, z PROVIDE A UNIFORMED LAW ENFORCEMENT OFFICER OR FLAGGER TO PREVENT VEHICLES FROM STOPPING WITHIN THE GRADE CROSSING. PROVIDE OFFICER OR FLAGGER EVEN IF AUTOMATIC WARNING MEASURES ALREADY EXIST. c Q GENERAL NOTES FOR PILOT CAR OPERATIONS } < O I N 1- USE PILOT CARS WHEN DIRECTED BY THE ENGINEER. a 2- IF ROADWAY WIDTH IS LESS THAN 22 FEET (EOP TO EOP) CONES MAY NOT BE REQUIRED ALONG WORK AREA AND AT THE DISCRETION OF THE ENGINEER, CONES MAY BE OMITTED ALONG Q THE WORK AREA I� USING A PILOT CAR. W LJJ Z Q 3- CONES ARE ALWAYS REQUIRED IN THE UPSTREAM AND DOWNSTREAM TAPERS. 4- MOUNT SIGN G20-4 "PILOT CAR FOLLOW ME" AT A CONSPICUOUS POSITION ON THE REAR OF THE PILOT VEHICLE. N 5 DO NOT INSTALL MORE THAN ONE (1) MILE OF LANE CLOSURE MEASURED FROM THE BEGINNING OF THE MERGE TAPER Tb THE END OF THE LANE CLOSURE. 6 ADVISE RESIDENTS AND BUSINESSES WITHIN THE LANE CLOSURE LIMITS ABOUT METHODS OF SAFE EGRESS AND INGRESS FROM DRIVEWAYS DURING FLAGGING AND PILOT CAR OPERATIONS. FLAGGER CONE IQ PORTABLE SIGN DIRECTION OF TRAFFIC FLOW SHEET 1 OF 14 1101 .02 wa W a 1�' REVISIONS REV DATE I COMMENT I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD 1. D.: NCC18211OSD0 PROJECT: � RKA HEIGHTS FOR d ><RKA HEIGHTS LLC LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY LD)00 � ��� )ENGINIEERING NC, P LILC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 61 NC@BohlerEng.com rSHEET TITLE: NCDOT DETAILS SHEET NUMBER: C-807 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211OSDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:59 PM LAST SAVED BY: MMOORE I I I I L9 9 I II II I 9 SEE NOTE 4 SIDEWALK SIDEWALK SEE - - - NOTE 12 _J - - - SEE ,Z, U) 4'-0" (TYP) NOTE 3 c ct STOP LINE 100 SEE NOTE 10 - _ -SIDEWALK - _ _ - - - - - DETAIL SHOWING TYPICAL LOCATION OF CURB RAMPS. PEDESTRIAN CROSSWALKS AND STOP LINES FOR TEE INTERSECTIONS G99 I II II I 9ya � SIDEWALK SIDEWALK _ SEE NOTE 12 SEE NOTE 10 Y 4'-0" (TYP) Q STOP LINE g o SIDEWALK SIDEWALK SEE NOTE 4 \ DETAIL SHOWING TYPICAL LOCATION OF CURB RAMPS, PEDESTRIAN CROSSWALKS AND STOP LINES ROADWAY PLAN SYMBOL C R PROPOSED CURB RAMP W/ LANDING FOR PROPOSED PROPOSED OR FUTURE SIDEWALK CURB RAMP ALLOWABLE LOCATIONS ------------------- DUAL RAMP RADII ........... ANY o CONTINUOUS LINES � H Q � �ci EDGE LINE LL Z 4"/6" 00 S cc U) YELLOW OR WHITE L.I..IQQLL2 QUcc: 0C.D F- U) H LANE LINE -i cc OO�Q 4" /6„ Z HcrWHITE I> -I r CL r Q CENTER LINE YELLOW 4"/6„ GORE LINE 8"/12" WHITE 0 cr Lu DIAGONAL LINE J 12" 45 MPH OR HIGHER 8" LESS THAN 45 MPH fz1 YELLOW OR WHITE QCD CL 0 � z CROSSWALK LINE OQC m 8" TRANSVERSE Q c WHITE 24" LONGITUDINAL z m U �..� >- o RxR LINE Q 0 CL 16" QO 0 0- WHITE STOP OR TRANSVERSE BAR 24" WHITE 848. 10'-30'/SP SKIP LINE UNLESS OTHERWISED SHOWN, USE 10'-30'/SP SKIPS FOR SKIP LANE LINES AND SKIP CENTER LINES. 10' 30' O O 4"/6" YELLOW OR WHITE 3'-3'/SP MINI -SKIP LINE UNLESS OTHERWISED SHOWN, USE 3'-3'/SP MINI -SKIPS FOR THE WHITE EDGE LINE ENTENSIONS AT ROUNDABOUTS. 3' 3' " 12" WHITE 2'-6'/SP MINI -SKIP LINE UNLESS OTHERWISED SHOWN, USE 2'-6'/SF MINI -SKIPS FOR LANE LINE EXTENSIONS THROUGH INTERSECTIONS, EDGE LINE EXTENSIONS THROUGH INTERSECTIONS AND MINI -SKIPS USED FOR BICYCLE LANE LINES. 2' 6' O O 4"/6" YELLOW OR WHITE 3'-9'/SP MINI -SKIP LINE UNLESS OTHERWISED SHOWN, USE 3'-9'/SP MINI -SKIPS FOR MINI -SKIP LANE LINES AND LINE EXTENSIONS THROUGH TAPERS. 3' 9' WHITE GENERAL NOTES: 1- USE 6" LANE, EDGE, AND CENTER LINES ON ALL FULL CONTROL OF ACCESS FACILITIES AND OTHER ROUTES AS DIRECTED BY THE ENGINEER. 2- LANE LINES INDICATED AS "WIDE" ON THE ROADWAY STANDARD DRAWINGS SHALL BE AT LEAST TWICE THE WIDTH OF THE NORMAL LINE. 3- GORE LINES SHALL BE TWICE THE WIDTH OF THE NORMAL LINE. SIDEWALK (5' STD.) 3"R 6" A B UTILITY STRIP DROP CURB 2' DETECTABLE 0.02 (MIN.) q" G &SGDUTTER SHOWN)6 WARNING DOMES 0.04 (NORM)) 0.02 (NORM.) 912:1 MAX. RAMP X ISOMETRIC VIEW PAY LIMITS FOR CURB RAMP NOTES: 1. DETECTABLE WARNING DOMES WILL COVER 2'-0" LENGTH AND FULL WIDTH OF THE RAMP FLOOR AS SHOWN ON THE DETAILS. 2. DETECTABLE WARNING DOMES WILL CONTRAST VISIBILITY WITH ADJOINING SURFACE, EITHER LIGHT -ON -DARK, OR DARK -ON -LIGHT SEQUENCE COVERING THE ENTIRE RAMP. RAMP WIDTH AREA IS VARIABLE 0 0 @ @ @ 0 = BASE DIAMETER 0.9"R TO 1.40"R 0 0 0 0 0 TOP DIAMETER OF NO LESS o THAN 50% TO NO MORE O O O O O THAN 65% OF THE BASE DIAMETER W A W+A+9" X B 5' 0.0' 5. 8' 5.8' 5. 0'* 6' 0.0' 6.8' 6. 8' 6. o' 7' 0.0' 7.8' 7.3' 6.5' * * 8' 0.0' 8.8, 7.3' 6.5' * * 5' 2.0' 7.8' 7.8' 5.0' 5' 2.5' 8.3' 8. 1' 4.8' 5' 3.0' 8.8' 8. 3' 4. 4' 5' 3.5' 9.3' 8.4' 4.1' 5' 4.0' 9.8' 8.6' 3.8' 5' 4.5' 10. 3' 8. 7' 3. 4' 5' 5.0' 10. 8' 8.9' 3. 1 ' 10.4 TO MIN �'. 2.4 TO B = X-(A+9" ) -L B = DISTANCE FROM FRONT EDGE OF SIDEWALK TO BACK POINT OF 12:1 (8.33.) SLOPE. BACK OF SIDEWALK DROP REQUIRED FOR ALL SIDEWALK SLOPES. ** BACK OF SIDEWALK DROP REQUIRED FOR SIDEWALK SLOPES 0.04. DETECTABLE WARNING DOMES GENERAL NOTES: IN THE 4" CONC. PAVED DITCHES, PLACE %2" EXPANSION JOINTS AT 30' INTERVALS AND AT ALL OTHER POINTS WHERE PROPOSED DITCHES ABUT RIGID OBJECTS. PLACED GROOVED JOINTS 1" DEEP AT 10' INTERVALS BETWEEN EXPANSION JOINTS. CONSTRUCT WIDTH AND SHAPE OF PROPOSED 4" CONCRETE PAVED DITCHES AS SHOWN OR AS DIRECTED BY THE ENGINEER. FOR DITCH GRADES ABOVE 2% EROSION CONTROL, INSTALL MATTING ON BOTH SIDES OF THE PAVING FOR A MINIMUM WIDTH OF 36" OR AS DIRECTED BY THE ENGINEER. SIDEWALK 5' MIN. 4' 5' MIN TOP OF ELEVATION TRANSITION CURB TRANSITION CURB GUTTER VARIABLE SLOPES NOT TO EXCEED 10:1 z O U) } Q Q LL -1 01 O O U) 2 cr w Q z W 2 QUCC0c!) I-=~zw (nl-WOJ Qcf)am C) Q Z ,j 1 CL W cc O LL W Z 0 LLI H Z U) QIe LWL or O Q 0 Qrt Q Z Z W W U F- LU Q > Lu Z � d J Q O SHEET 1 OF 2 H cf) < Q Q " CD U LLJCL OH 0 0 2 Z w Q z W 3 Q0 00-I H 2 Z W U)HWOJ O cc 0 U) Q z H - CL Lu Q 0 v SIDEWALK 'ANSION JOINT 0 cc .E STD. 846.01) LL NOTE: A PORTION OF ONE OR BOTH RAMPS LLJ CL. MAY EXTEND OUTSIDE THE RETURN. CD w a EXPANSION JOINT Fo, SEE NOTE 4' x 4' (SEE STD. 848.01) z z LANDING w= \ Q Q �a 0 fe EXPANSION JOINT m (SEE STD. 846.01) 0 m :D SIDEWALK cc U Q H V 0 (n w / 4' X 4' CLEAR SPACE 0 0 MUST FALL WITHIN CROSSWALK LIMITS. Q O (SEE NOTE 10) 2' MIN. CURB t� Q Occ: EL BETWEEN RAMPS / / J SEE NOTE 1 SEE NOTES 2, 12 & 14 PLAN VIEW (4MIN. FLOOR WIDTH) VARIABLE -F VARIABLE - N H - - VAR . / ANG �E BASE DITCH OR BERM DRAINAGE OUTLET DITCH JOINT SEALER 1/2 2'-0" 2'-0" BERM DITCH a 3'-0"± 3'-0°± MEDIAN DITCH 1/8" RADIUS 1/g" RADIUS T a v ih JOINT FILLER JOINT SEALER SHOWING GROOVED JOINT SHOWING EXPANSION JOINT MEDIAN OR BERM DITCH 6 0 a VARIABLE v SHOULDER POINT f SIDE DITCH (0 �u L PART LONGITUDINAL SECTION OF PAVED DITCH SHOWING 1'-6" CURTAIN WALL REQUIRED AT EACH END * WHEN CURTAIN WALL FOR PAVED DITCH IS LOCATED ADJACENT TO A DRAINAGE STRUCTURE AND THE PIPE FROM THE STRUCTURE INTERFERES WITH THE V-6" DEPTH, THE DEPTH OF THE CURTAIN WALL MAY BE REDUCED BELOW V-6" TO CLEAR THE TOP OF THE PIPE. 12' VERTICAL CURVE a :10- TO SHOO DER POINT 12' V.C. ROADWAY DITCH MEET 1 OF 3 848.05 ROAD CLOSED AHEAD 20-3 4a" x Sall N FXT IFFT NOTE: USE SIGN R11-4 IE NOTE: PLACE WING BARRIACADES WITH R11-3 1 MILE OR LESS TO ROAD CLOSED R11-4 SIGN AT THROUGH SIDE ROADS BETWEEN ROAD CLOSUHE. THE DETOUR POINT AND THE POINT OF 10 60" X 30" CLOSURE, THRU TRAFFIC R11-3 60" X 30" ROAD eCLOS�ED �© M4-10RISHOWN) OH M4-10L 48" X 18" TYPE III WING BARRICADES it I 1 I'ED I i t �" CLOSED 10 HEAD W20-3 48" X 48" SOD" So'. CLOSED 3 4C CLOSED 000 f 500 FT W21-3 W20-3 48" X 4B" 48" X 48" TYPE III BARRICADE(S) WORK AREA z o (,) Q LL- -i OOU)2 IV' QQLL2 QU�O10-II H V)HWOJ 00U)C2 Z F-I IL H 0 0 cc N H LL O � fz1 0 CL 48 X 0 H O NE%T RIGHT 42„4K 12" Q J 0 0 GENERAL NOTES 0 w 1- IF NECESSARY USE THIS RSD. FOR 2-LANE, 2-WAY, AND MULTILANE DIVIDED AND UNDIVIDED 0 Q 0 ROADWAYS. < O z 2- INSTALLATION OF DETOUR ROUTING PANELS, TEMPORARY ROUTE MARKERS; DESTINATION SIGNS, 0 D• O AND ANY NECESSARY MODIFICATIONS TO EXISTING OR PROPOSED REGULATORY OR WARNING SIGNS Z WILL BE MADE BY OTHERS (STATE OR CITY FORCES) UNLESS OTHERWISE DESIGNATED IN THE Q >- Lj PLANS. PROVIDE A MINIMUM 30 CALENDAR DAY NOTICE TO STATE FORCES BEFORE A ROADWAYcc co IS CLOSED TO TRAFFIC SUCH THAT THE NECESSARY PROVISIONS CAN BE MADE TO INSTALL DETOUR ROUTE SIGNS, INFORM LOCAL EMERGENCY AND LAW ENFORCEMENT PERSONNEL, SCHOOLS, W OR ANY OTHER PARTIES AFFECTED BY THE ROAD CLOSURE. O d 3- INSTALL SIGNS BEFORE THE BARRICADES WHEN CLOSING THE ROADWAY TO TRAFFIC. REMOVE Q Lu 0 BARRICADES BEFORE SIGNS WHEN OPENING THE ROADWAY TO TRAFFIC. INSTALL/REMOVE SIGNS O AND BARRICADES WITHIN THE SAME CALENDAR DAY. CC � U 4- USE ADDITIONAL TYPE III BARRICADES IN STAGGERED LOCATIONS SUPPLEMENTED WITH SIGN R11-4 "ROAD CLOSED TO THRU TRAFFIC" IN THE EVENT THAT TRAFFIC MUST BE MAINTAINED BEYOND THE DETOUR POINT. 5- DO NOT DISPLAY FRACTIONS OR DECIMALS ON SIGN R11-3 "ROAD CLOSED XX MILES AHEAD". 6- POSITION WING BARRICADES ON THE SHOULDERS AND SLOPE THE STRIPES DOWNWARD IN THE LEGEND DIRECTION TOWARD WHICH TRAFFIC MUST TURN IN DETOURING. STATIONARY SIGN SHEET 1 OF 9 7- USE PORTABLE SIGNS IF ROAD CLOSURE IS TO BE IMPLEMENTED FOR LESS THAN THREE DAYS, DIRECTION OF TRAFFIC FLOW 11101.03 OR FOR EMERGENCIES. SEE EDGE LINE z EDGE LINE OFFSET DETAIL OFFSET DETAIL TWO-WAY UNDIVIDED ROADWAY H} �2" MAX., REFER ALSO TO TABLE 1 Q Q E.O.T. Iz-I U W - « LLJOH -- - ---- ----- -- ---- Z 00�= cc CENTER LINE OFFSET DETAIL LANE LINE OFFSET DETAIL 3" 6 3" TABLE 1 EDGE LINE OFFSETS FOR 2-LANE, 2-WAY ROADWAYS WITH UN -PAVED SHOULDERS WIDTH (W) OF TRAVEL PAVEMENT MAX. EDGE LINE OFFSET FROM E.O.T. MINIMUM LANE WIDTH (W) 16' - 18' 2" 8' - 9' 19, 4" 9' 20' 6" 9.5' 21' 8" 10' 22' loll 10' 23' loll 10. 5' 24' 1' 11' 26' 2' ill 28' 2' 12' 30' 3' 12' 32' 1 4' 12' LEGEND W = WIDTH OF TRAVEL LANE E.O.T.= EDGE OF TRAVEL a DIRECTION OF » TRAFFIC FLOW 2" TOWARDS LEFT SIDE OF TRAVELWAY z DIRECT TAPER TURN LANE �} WHITE 3'-9'/SP MINI -SKIP LINE Q < END OF TAPER _ �_ _ _ _ _ Iz-I cr 0U TAPER LLJ2i�Hz 00(n= 10' w< LL3 QU�OUI F- ~ z0 w TURN LANE BAYS 125 250 FT. WHITE LANE LINE L- J z cc O U) r '> CL H so' TURN LANE BAY O N LL = CD C� Z F-i Qo 0 G W Q Q 0a Z F W U) W 3: 0 QO cc V W » W Q Q W 2 Qv°Co� H = Z W U)HWOJ SEE EDGE LINE SEE CENTER LINE OC O I --I Q OFFSET DETAIL z H CC OFFSET DETAIL H> H r W 0 SEE EDGE LINE TWO-WAY UNDIVIDED ROADWAY OFFSET DETAIL WITH TWO-WAY LEFT TURN LANE SEE EDGE LINE OFFSET DETAIL SEE EDGE LINE OFFSET DETAIL W 9. W- -_ SEE EDGE LINE OFFSET DETAIL -r--_----r--' O LL N H Q oC Z U) LL ~ LL Y O SEE CENTER LINE OFFSET DETAIL 0 CQC G Q 0 U) QLLI Z IL W cf) W I-- MULTI -LANE ROADWAY Q > 0 Q z d J SEE LANE LINE OFFSET DETAIL TURN LANE BAYS < 125 FT.I WHITE 3'-9'/SP MINI -SKIP LINE WHITE LANE - � - LINE r TAPER 17 TURN LANE ARROW CENTERED IN BAY TURN LANE BAY WHITE 3'-9'/SP MINI -SKIP LINE TAPER TURN LANE BAYS 250 FT. OR GREATER I CENTER BETWEEN FIRST AND LAST ARROWS 250' WHITE 3'-9'/SP MINI -SKIP LINE WHITE LANE LINE - - - - - - r r r jjj 60' TAPER TURN LANE BAY LEFT TURN LANE DEVELOPED FROM TWO-WAY TURN LANE WHITE LANE LINE, CENTER BETWEEN FIRST WHITE 3'-9'/SP MINI -SKIP LINE 1/p LENGTH OF BAY - AND LAST ARROWS- - - TWO-WAY LEFT TURN LANE r r r S r 60' TURN LANE BAY 160' SAME PAVEMENT MARKING LINES, NUMBER OF ARROWS, AND ARROW SPACING APPLY AS FOR THE VARIOUS DOUBLE TURN LANES TURN LANE BAY LENGTHS SHOWN ABOVE i WHITE SKIP LANE LINE WHITE 3'-9'/SP MINI -SKIP LINE WHITE E LINE, 1/2 LENGHT OF BAY \ WHITE E E, LENGHT OF BAY � UP T125MAX T250MAX \ WHITE 2'-6'/SP MINI -SKIP r r LINE TAPER 60' CENTER BETWEEN FIRST GENERAL NOTES: -IFFT 1 OF 1 1- USE THE GUIDANCE SHOWN ABOVE IN CONJUNCTION WITH THE INTERSECTION GUIDANCE SHOWN ON ROADWAY STANDARD DRAWING 1205.04. 2- THE NUMBER OF ARROWS SHOWN IS THE MINIMUM REQUIRED. USE ADDITIONAL ARROWS AS DIRECTED BY THE ENGINEER. 850.01 1205.01 Z O U) } Q Q cr LLJCLHZ OOU)2 c w Q z W 2 QU�O01 H H- = z w U)HWOJ o o0Q z cr H I �> ao W LEGEND PAVEMENT MARKING FEET 1 OF 1 r SYMBOL 205.05 w Wa a �z �z a w O W z �W a z z ����� 4'l z r� ? pp ZF. i LL a z 3 REVISIONS REV DATE COMMENT BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. NOT APPROVED FOR CONSTRUCTION PROJECT No.: NCC182110 DRAWN BY: SOM CHECKED BY: SRF DATE: 12/11 /2019 SCALE: 1 "=60' CAD I.D.: NCC18211OSD0 PROJECT: AIRKA JL\ HEIGHTS FOR ARKA ]H[�E/JIV,i.IIHTS LL �1.� LOCATION OF SITE 4610 OLD CHARLOTTE HIGHWAY MONROE, NC 28110 UNION COUNTY r BOH LER ENGINEERING NC, PLLC NCBELS P-1132 1927 S. TRYON STREET, SUITE 310 CHARLOTTE, NC 28203 Phone: (980) 272-3400 Fax: (980) 272-3401 NC@BohlerEng.com rSHEET TITLE: NC DOT DETAILS SHEET NUMBER: C-808 H:\2018\NCC182110\DRAWINGS\PLAN SETS\CONSTRUCTION DOCUMENTS\NCC18211OSDO.DWG PRINTED BY: MMOORE 12.16.19 @ 5:59 PM LAST SAVED BY: MMOORE